Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Monte Carlo calculated TG-60 dosimetry parameters for the {beta}{sup -} emitter {sup 153}Sm brachytherapy source

Purpose: The formalism recommended by Task Group 60 (TG-60) of the American Association of Physicists in Medicine (AAPM) is applicable for {beta} sources. Radioactive biocompatible and biodegradable {sup 153}Sm glass seed without encapsulation is a {beta}{sup -} emitter radionuclide with a short half-life and delivers a high dose rate to the tumor in the millimeter range. This study presents the results of Monte Carlo calculations of the dosimetric parameters for the {sup 153}Sm brachytherapy source. Methods: Version 5 of the (MCNP) Monte Carlo radiation transport code was used to calculate two-dimensional dose distributions around the source. The dosimetric parameters of AAPM TG-60 recommendations including the reference dose rate, the radial dose function, the anisotropy function, and the one-dimensional anisotropy function were obtained. Results: The dose rate value at the reference point was estimated to be 9.21{+-}0.6 cGy h{sup -1} {mu}Ci{sup -1}. Due to the low energy beta emitted from {sup 153}Sm sources, the dose fall-off profile is sharper than the other beta emitter sources. The calculated dosimetric parameters in this study are compared to several beta and photon emitting seeds. Conclusions: The results show the advantage of the {sup 153}Sm source in comparison with the other sources because of the rapid dose fall-off of beta ray and high dose rate at the short distances of the seed. The results would be helpful in the development of the radioactive implants using {sup 153}Sm seeds for the brachytherapy treatment.

60 APPLIED LIFE SCIENCES↗

Analysis of burnup and isotopic compositions of BWR 9 x 9 UO{sub 2} fuel assemblies

In order to extend isotopic composition data focusing on fission product nuclides, measurements are progressing using facilities of JAEA for five samples taken from high burnup BWR 9 x 9 UO{sub 2} fuel assemblies. Neutronics analysis with an infinite assembly model was applied to the preliminary measurement data using a continuous-energy Monte Carlo burnup calculation code MVP-BURN with nuclear libraries based on JENDL-3.3 and JENDL-4.0. The burnups of the samples were determined to be 28.0, 39.3, 56.6, 68.1, and 64.0 GWd/t by the Nd-148 method. They were compared with those calculated using node-average irradiation histories of power and in-channel void fractions which were taken from the plant data. The comparison results showed that the deviations of the calculated burnups from the measurements were -4 to 3%. It was confirmed that adopting the nuclear data library based on JENDL-4.0 reduced the deviations of the calculated isotopic compositions from the measurements for {sup 238}Pu, {sup 144}Nd, {sup 145}Nd, {sup 146}Nd, {sup 148}Nd, {sup 134}Cs, {sup 154}Eu, {sup 152}Sm, {sup 154}Gd, and {sup 157}Gd. On the other hand, the effect of the revision in the nuclear. data library on the neutronics analysis was not significant for major U and Pu isotopes. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-T-115: Uncertainty in the Esophagus Dose in Retrospective Epidemiological Study of Breast Cancer Radiotherapy Patients

Purpose: Epidemiological studies of second cancer risks in breast cancer radiotherapy patients often use generic patient anatomy to reconstruct normal tissue doses when CT images of patients are not available. To evaluate the uncertainty involved in the dosimetry approach, we evaluated the esophagus dose in five sample patients by simulating breast cancer treatments. Methods: We obtained the diagnostic CT images of five anonymized adult female patients in different Body Mass Index (BMI) categories (16– 36kg/m2) from National Institutes of Health Clinical Center. We contoured the esophagus on the CT images and imported them into a Treatment Planning System (TPS) to create treatment plans and calculate esophagus doses. Esophagus dose was calculated once again via experimentally-validated Monte Carlo (MC) transport code, XVMC under the same geometries. We compared the esophagus doses from TPS and the MC method. We also investigated the degree of variation in the esophagus dose across the five patients and also the relationship between the patient characteristics and the esophagus doses. Results: Eclipse TPS using Analytical Anisotropic Algorithm (AAA) significantly underestimates the esophagus dose in breast cancer radiotherapy compared to MC. In the worst case, the esophagus dose from AAA was only 40% of the MC dose. The Coefficient of Variation across the patients was 48%. We found that the maximum esophagus dose was up to 2.7 times greater than the minimum. We finally observed linear relationship (Dose = 0.0218 × BMI – 0.1, R2=0.54) between patient’s BMI and the esophagus doses. Conclusion: We quantified the degree of uncertainty in the esophagus dose in five sample breast radiotherapy patients. The results of the study underscore the importance of individualized dose reconstruction for the study cohort to avoid misclassification in the risk analysis of second cancer. We are currently extending the number of patients up to 30.

60 APPLIED LIFE SCIENCES↗

Enhanced epidermal dose caused by localized electron contamination from lead cutouts used in kilovoltage radiotherapy

Purpose: To investigate and quantify electron contamination from the lead cutouts used in kilovoltage x-ray radiotherapy. Methods: The lead cutouts were modeled with the Monte Carlo EGSnrc user codes DOSXYZnrc and DOSRZnrc for x-ray beams ranging from 50 to 300 kV{sub p}. The results from the model were confirmed with Gafchromic film measurements. The model and measurements investigated the dose distribution with and without gladwrap shielding under the lead, and dose distributions with round, square, and serrated edge cutouts. Results: Large dose enhancement near the edges of the lead was observed due to electron contamination. At the epidermal/dermal border, there is double the dose at the edge of the lead compared to the central dose due to electron contamination for a 150 kV{sub p} beam and three times the dose for a 300 kV{sub p} beam. gladwrap shielding effectively removes the contaminant dose enhancement using ten and four layers for 300 and 150 kV{sub p} beams, respectively. Conclusions: The contaminant dose enhancement is undesirable as it could cause unnecessary erythema and hyperpigmentation at the border of the treated and untreated skin and lead to a poorer cosmetic outcome. The contamination is easily removed by gladwrap shielding placed under or around the lead cutout.

60 APPLIED LIFE SCIENCES↗

CONSTRAINING THE MOVEMENT OF THE SPIRAL FEATURES AND THE LOCATIONS OF PLANETARY BODIES WITHIN THE AB AUR SYSTEM

We present a new analysis of multi-epoch, H -band, scattered light images of the AB Aur system. We use a Monte Carlo radiative transfer code to simultaneously model the system’s spectral energy distribution (SED) and H -band polarized intensity (PI) imagery. We find that a disk-dominated model, as opposed to one that is envelope-dominated, can plausibly reproduce AB Aur’s SED and near-IR imagery. This is consistent with previous modeling attempts presented in the literature and supports the idea that at least a subset of AB Aur’s spirals originate within the disk. In light of this, we also analyzed the movement of spiral structures in multi-epoch H -band total light and PI imagery of the disk. We detect no significant rotation or change in spatial location of the spiral structures in these data, which span a 5.8-year baseline. If such structures are caused by disk–planet interactions, the lack of observed rotation constrains the location of the orbit of planetary perturbers to be >47 au.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulations of a high-density, highly-radiating lithium divertor

Results are presented for one- and two-dimensional (2D) edge plasma transport simulations for strong injection of lithium (Li) in the divertor region of a tokamak. The model includes the scrape-off layer and divertor regions, and, for 2D, a small region inside the magnetic separtrix. Equations are solved for the density and momentum of a deuterium/tritium (DT) species and all three charge states of Li, in addition to separate ion and electron energy equations via the UEDGE code. Equations are also included for the DT and Li gas species. Lithium gas is injected from the side walls or divertor plate, implying that these surfaces are evaporating liquid Li. For a range of Li gas input, steady-state, detached-plasma solutions are shown where greater than 90% of the exhaust power is radiated by Li, resulting in peak surface heat fluxes ~2 MW/m 2 on the divertor plate, outer wall, and private-flux wall. While Li ions dominate in the divertor leg, their density is in the range of 10% of the DT density at the midplane. The collisional parallel thermal force plays a key role in determining the midplane ion Li density, and sensitivity of results to different model assumptions are discussed. Here the key issue is possible dilution of the core DT fuel. A brief comparison of the Li neutral solution is made with that from the Direct Simulation Monte-Carlo (DSMC) SPARTA code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FAR-ULTRAVIOLET OBSERVATIONS OF THE TAURUS-PERSEUS-AURIGA COMPLEX

We have constructed a far-ultraviolet (FUV) continuum map of the Taurus-Auriga-Perseus complex, one of the largest local associations of dark clouds, by merging the two data sets of Galaxy Evolution Explorer and FUV Imaging Spectrograph, which made observations at similar wavelengths. The FUV intensity varies significantly across the whole region, but the diffuse FUV continuum is dominated by dust scattering of stellar photons. A diffuse FUV background of {approx}1000 CU is observed, part of which may be attributable to the scattered photons of foreground FUV light, located in front of the thick clouds. The fluorescent emission of molecular hydrogen constitutes {approx}10% of the total FUV intensity throughout the region, generally proportional to the local continuum level. We have developed a Monte Carlo radiative transfer code and applied it to the present clouds complex to obtain the optical properties of dust grains and the geometrical structures of the clouds. The albedo and the phase function asymmetry factor were estimated to be 0.42{sup +0.05}{sub -0.05}, and 0.47{sup +0.11}{sub -0.27}, respectively, in accordance with theoretical estimations as well as recent observations. The distance and thickness of the four prominent clouds in this complex were estimated using a single-slab model applied individually to each cloud. The results obtained were in good agreement with those from other observations of the Taurus cloud, as its geometrical structure is rather simple. For other clouds that were observed to have multiple components, the results gave distances and thicknesses encompassing all of the components of each cloud. The distance and thickness estimations were not crucially sensitive to the exact values of the albedo and the phase function asymmetry factor, while the locations of the bright field stars relative to the clouds as initial photon sources seem to be the most important factor in the process of fitting.

79 ASTRONOMY AND ASTROPHYSICS↗

A new 'Implicit correlation' method for cross-correlation sampling in MCNPX-PoliMi

Monte Carlo particle transport codes used to accurately model detector response are traditionally run in fully analog mode. Analog simulations of cross-correlation measurements with these codes are extremely time-consuming because the probability of correlated detection is extremely small, approximately equal to the product of the probabilities of a single detection in each detector. The new 'implicit correlation' method described here increases the number of correlation event scores thereby reducing variance and required computation times. The cost of the implicit correlation method is comparable to the cost of simulating single event detection for the lowest absolute detector efficiency in the problem. This method is especially useful in the nuclear non-proliferation and safeguards fields for simulating correlation measurements of shielded special nuclear material. The new method was implemented in MCNPX-PoliMi for neutron-neutron cross-correlations with a Cf-252 spontaneous fission source measured by two detectors of variable stand-offs. The method demonstrated good agreement with analog simulation results for multiple measurement geometries. Small differences between non-analog and analog cross-correlation distributions are attributed to known features of the specific problem simulated that will not be present in practical applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Midplane neutral density profiles in the National Spherical Torus Experiment

Atomic and molecular density data in the outer midplane of NSTX [Ono et al., Nucl. Fusion 40, 557 (2000)] are inferred from tangential camera data via a forward modeling procedure using the DEGAS 2 Monte Carlo neutral transport code. The observed Balmer-b light emission data from 17 shots during the 2010 NSTX campaign display no obvious trends with discharge parameters such as the divertor Balmer-a emission level or edge deuterium ion density. Simulations of 12 time slices in 7 of these discharges produce molecular densities near the vacuum vessel wall of 2–8 x 10 17 m -3 and atomic densities ranging from 1 to 7 x 10 16 m -3 ; neither has a clear correlation with other parameters. Validation of the technique, begun in an earlier publication, is continued with an assessment of the sensitivity of the simulated camera image and neutral densities to uncertainties in the data input to the model. The simulated camera image is sensitive to the plasma profiles and virtually nothing else. The neutral densities at the vessel wall depend most strongly on the spatial distribution of the source; simulations with a localized neutral source yield densities within a factor of two of the baseline, uniform source, case. The uncertainties in the neutral densities associated with other model inputs and assumptions are ≤ 50%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mobile Pit verification system design based on passive special nuclear material verification in weapons storage facilities

A mobile 'drive by' passive radiation detection system to be applied in special nuclear materials (SNM) storage facilities for validation and compliance purposes has been designed through the use of computational modeling and new radiation detection methods. This project was the result of work over a 1 year period to create optimal design specifications to include creation of 3D models using both Monte Carlo and deterministic codes to characterize the gamma and neutron leakage out each surface of SNM-bearing canisters. Results were compared and agreement was demonstrated between both models. Container leakages were then used to determine the expected reaction rates using transport theory in the detectors when placed at varying distances from the can. A 'typical' background signature was incorporated to determine the minimum signatures versus the probability of detection to evaluate moving source protocols with collimation. This established the criteria for verification of source presence and time gating at a given vehicle speed. New methods for the passive detection of SNM were employed and shown to give reliable identification of age and material for highly enriched uranium (HEU) and weapons grade plutonium (WGPu). The finalized 'Mobile Pit Verification System' (MPVS) design demonstrated that a 'drive-by' detection system, collimated and operating at nominally 2 mph, is capable of rapidly verifying each and every weapon pit stored in regularly spaced, shelved storage containers, using completely passive gamma and neutron signatures for HEU and WGPu. This system is ready for real evaluation to demonstrate passive total material accountability in storage facilities. (authors)

97 MATHEMATICS AND COMPUTING↗

Experimental validation of a high fidelity Monte Carlo neutron transport model of the MIT graphite exponential pile

High-fidelity modeling and simulation were performed for the MIT graphite exponential pile (MGEP) using Monte Carlo neutron transport codes OpenMC and MCNP, and the results were validated by experimental data. The MGEP is being used as the test bed for the design of an autonomous control system for the pile's neutron flux distribution. The main contribution of this work is to generate the training data sets of neutron flux distributions with different locations of control rods that perturb the neutron flux profiles. First, code -to-code cross verification between OpenMC and MCNP was performed to ensure consistency of the numerical modeling within statistical uncertainties. To validate the accuracy of this high-fidelity model, a series of neutron flux measurements were conducted using a Helium-3 (He-3) neutron detector on a mobile platform that is placed inside the pile. Second, the neutron flux profiles were measured in four vertical layers of interest, and compared to the corresponding simulation results. The comparison results shows that the root mean square error is less than 2.5% in the two upper layers, and less than 4.5% in all four measured layers. Here the results validated the accuracy of the modeling and simulation. Finally, the relative change of the neutron flux profiles from moving control rods was analyzed, which identified the layer that has the best sensitivity regarding the control rods movements. Thus, this work identified and provided training data sets of both simulated and experimental neutron flux profiles in the most sensitive layer, paving the path forward to the real-time experimental demonstration of the autonomous control system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-T-559: Monte Carlo Simulation of Cobalt-60 Teletherapy Unit Modeling In-Field and Out-Of-Field Doses for Applications in Computational Radiation Dosimetry

Purpose: Mean organ doses from structures located in field and outside of field boundaries during radiotherapy treatment must be considered when looking at secondary effects. Treatment planning in patients with 40 years of follow-up does not include 3-D treatment planning images and did not estimate dose to structures out of the direct field. Therefore, it is of interest to correlate actual clinical events with doses received. Methods: Accurate models of radiotherapy machines combined with whole body computational phantoms using Monte Carlo methods allow for dose reconstructions intended for studies on late radiation effects. The Theratron-780 radiotherapy unit and anatomically realistic hybrid computational phantoms are modeled in the Monte Carlo radiation transport code MCNPX. The major components of the machine including the source capsule, lead in the unit-head, collimators (fixed/adjustable), and trimmer bars are simulated. The MCNPX transport code is used to compare calculated values in a water phantom with published data from BJR suppl. 25 for in-field doses and experimental data from AAPM Task Group No. 36 for out-of-field doses. Next, the validated cobalt-60 teletherapy model is combined with the UF/NCI Family of Reference Hybrid Computational Phantoms as a methodology for estimating organ doses. Results: The model of Theratron-780 has shown to be agree with percentage depth dose data within approximately 1% and for out of field doses the machine is shown to agree within 8.8%. Organ doses are reported for reference hybrid phantoms. Conclusion: Combining the UF/NCI Family of Reference Hybrid Computational Phantoms along with a validated model of the Theratron-780 allows for organ dose estimates of both in-field and out-of-field organs. By changing field size, position, and adding patient-specific blocking more complicated treatment set-ups can be recreated for patients treated historically, particularly those who lack both 2D/3D image sets.

61 RADIATION PROTECTION AND DOSIMETRY↗

PANCHROMATIC IMAGING OF A TRANSITIONAL DISK: THE DISK OF GM AUR IN OPTICAL AND FUV SCATTERED LIGHT

We have imaged GM Aurigae with the Hubble Space Telescope , detected its disk in scattered light at 1400 and 1650 Å, and compared these with observations at 3300 Å, 5550 Å, 1.1 μ m, and 1.6 μ m. The scattered light increases at shorter wavelengths. The radial surface brightness profile at 3300 Å shows no evidence of the 24 au radius cavity that has been previously observed in submillimeter observations. Comparison with dust grain opacity models indicates that the surface of the entire disk is populated with submicron grains. We have compiled a spectral energy distribution from 0.1 μ m to 1 mm and used it to constrain a model of the star + disk system that includes the submillimeter cavity using the Monte Carlo radiative transfer code by Barbara Whitney. The best-fit model image indicates that the cavity should be detectable in the F330W bandpass if the cavity has been cleared of both large and small dust grains, but we do not detect it. The lack of an observed cavity can be explained by the presence of submicron grains interior to the submillimeter cavity wall. We suggest one explanation for this that could be due to a planet of mass <9 M {sub J} interior to 24 au. A unique cylindrical structure is detected in the far-UV data from the Advanced Camera for Surveys/Solar Blind Channel. It is aligned along the system semiminor axis, but does not resemble an accretion-driven jet. The structure is limb brightened and extends 190 ± 35 au above the disk midplane. The inner radius of the limb brightening is 40 ± 10 au, just beyond the submillimeter cavity wall.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scan protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to a minimum while still maintaining clinically viable image quality.

60 APPLIED LIFE SCIENCES↗

Minibeam radiation therapy for the management of osteosarcomas: A Monte Carlo study

Purpose: Minibeam radiation therapy (MBRT) exploits the well-established tissue-sparing effect provided by the combination of submillimetric field sizes and a spatial fractionation of the dose. The aim of this work is to evaluate the feasibility and potential therapeutic gain of MBRT, in comparison with conventional radiotherapy, for osteosarcoma treatments. Methods: Monte Carlo simulations (PENELOPE/PENEASY code) were used as a method to study the dose distributions resulting from MBRT irradiations of a rat femur and a realistic human femur phantoms. As a figure of merit, peak and valley doses and peak-to-valley dose ratios (PVDR) were assessed. Conversion of absorbed dose to normalized total dose (NTD) was performed in the human case. Several field sizes and irradiation geometries were evaluated. Results: It is feasible to deliver a uniform dose distribution in the target while the healthy tissue benefits from a spatial fractionation of the dose. Very high PVDR values (⩾20) were achieved in the entrance beam path in the rat case. PVDR values ranged from 2 to 9 in the human phantom. NTD{sub 2.0} of 87 Gy might be reached in the tumor in the human femur while the healthy tissues might receive valley NTD{sub 2.0} lower than 20 Gy. The doses in the tumor and healthy tissues might be significantly higher and lower than the ones commonly delivered used in conventional radiotherapy. Conclusions: The obtained dose distributions indicate that a gain in normal tissue sparing might be expected. This would allow the use of higher (and potentially curative) doses in the tumor. Biological experiments are warranted.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-159: Monte Carlo Simulation Studies of Three-Dimensional Dose Distribution for Polymer Gel Dosimeter and Radiochromic Gel Dosimeter in a Proton Beam

Purpose: The purpose of this simulation study is to evaluate the proton detectability of gel dosimeters, and estimate the three-dimensional dose distribution of protons in the radiochromic gel and polymer gel dosimeter compared with the dose distribution in water. Methods: The commercial composition ratios of normoxic polymer gel and LCV micelle radiochromic gel were included in this simulation study. The densities of polymer and radiochromic gel were 1.024 and 1.005 g/cm3, respectively. The 50, 80 and 140 MeV proton beam energies were selected. The dose distributions of protons in the polymer and radiochromic gel were simulated using Monte Carlo radiation transport code (MCNPX 2.7.0, Los Alamos Laboratory). The water equivalent depth profiles and the dose distributions of two gel dosimeters were compared for the water. Results: In case of irradiating 50, 80 and 140 MeV proton beam to water phantom, the reference Bragg-peak depths are represented at 2.22, 5.18 and 13.98 cm, respectively. The difference in the water equivalent depth is represented to about 0.17 and 0.37 cm in the radiochromic gel and polymer gel dosimeter, respectively. The proton absorbed doses in the radiochromic gel dosimeter are calculated to 2.41, 3.92 and 6.90 Gy with increment of incident proton energies. In the polymer gel dosimeter, the absorbed doses are calculated to 2.37, 3.85 and 6.78 Gy with increment of incident proton energies. The relative absorbed dose in radiochromic gel (about 0.47 %) is similar to that of water than the relative absorbed dose of polymer gel (about 2.26 %). In evaluating the proton dose distribution, we found that the dose distribution of both gel dosimeters matched that of water in most cases. Conclusion: As the dosimetry device, the radiochromic gel dosimeter has the potential particle detectability and is feasible to use for quality assurance of proton beam therapy beam.

07 ISOTOPE AND RADIATION SOURCES↗

MONTE CARLO SIMULATIONS OF GLOBULAR CLUSTER EVOLUTION. V. BINARY STELLAR EVOLUTION

We study the dynamical evolution of globular clusters containing primordial binaries, including full single and binary stellar evolution using our Monte Carlo cluster evolution code updated with an adaptation of the single and binary stellar evolution codes SSE and BSE from Hurley et al. We describe the modifications that we have made to the code. We present several test calculations and comparisons with existing studies to illustrate the validity of the code. We show that our code finds very good agreement with direct N-body simulations including primordial binaries and stellar evolution. We find significant differences in the evolution of the global properties of the simulated clusters using stellar evolution compared with simulations without any stellar evolution. In particular, we find that the mass loss from the stellar evolution acts as a significant energy production channel simply by reducing the total gravitational binding energy and can significantly prolong the initial core contraction phase before reaching the binary-burning quasi-steady state of the cluster evolution. We simulate a large grid of models varying the initial cluster mass, binary fraction, and concentration parameter, and we compare properties of the simulated clusters with those of the observed Galactic globular clusters (GGCs). We find that simply including stellar evolution in our simulations and assuming the typical initial cluster half-mass radius is approximately a few pc independent of mass, our simulated cluster properties agree well with the observed GGC properties such as the core radius and the ratio of the core radius to the half-mass radius. We explore in some detail qualitatively different clusters in different phases of their evolution and construct synthetic Hertzsprung-Russell diagrams for these clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

COMPUTATIONAL MODELING OF THE CLASS I LOW-MASS PROTOSTAR ELIAS 29 APPLYING OPTICAL CONSTANTS OF ICES PROCESSED BY HIGH ENERGY COSMIC RAY ANALOGS

We present a study of the effects of high energy cosmic rays (CRs) over the astrophysical ices, observed toward the embedded class I protostar Elias 29, by using computational modeling and laboratory data. Its spectrum was observed with the Infrared Space Observatory (ISO) covering 2.3–190 μm. The modeling employed the three-dimensional Monte Carlo radiative transfer code RADMC-3D and laboratory data of bombarded ice grains by CR analogs and unprocessed ices (not bombarded). We are assuming that Elias 29 has a self-irradiated disk with inclination i = 60.°0, surrounded by an envelope with a bipolar cavity. The results show that absorption features toward Elias 29 are better reproduced by assuming a combination between unprocessed astrophysical ices at low temperature (H{sub 2}O, CO, CO{sub 2}) and bombarded ices (H{sub 2}O:CO{sub 2}) by high energy CRs. Evidences of the ice processing around Elias 29 can be observed by the good fitting around 5.5–8.0 μm, by polar and apolar ice segregation in 15.15–15.25 μm, and by the presence of the CH{sub 4} and HCOOH ices. Given that non-nitrogen compounds were employed in this work, we assume that absorption around 5.5–8.0 μm should not be associated with the NH{sub 4}{sup +} ion (see the 2003 work of Shutte and Khanna ), but more probably with aliphatic ethers (e.g., R1-OCH{sub 2}-R2), CH{sub 3}CHO, and related species. The results obtained in this paper are important because they show that the environment around protostars is better modeled considering processed samples and, consequently, demonstrate the chemical evolution of the astrophysical ices.

79 ASTRONOMY AND ASTROPHYSICS↗