Green and Cost Effective Synthesis of Fluorescent Carbon Quantum Dots for Dopamine Detection

Carbon quantum dots (CQDs) due to its high fluorescent output is evolving as novel sensing material and is considered as future building blocks for nano sensing devices. Hence, in this investigation we report microwave assisted preparation and multi sensing application of CQDs. The microwave derived CQDs are characterized by Dynamic Light Scattering (DLS) experiment and Fourier Infrared spectra (FTIR) to investigate the size distribution and chemical purity respectively. Fluorescent emission spectra recorded at varying pH shows varying fluorescence emission intensities. Further, emission spectra recorded at different temperatures shows that fluorescence emission of CQDs greatly depends on temperature. Therefore, we demonstrate the pH and temperature sensing characteristics of CQDs by fluorescence quenching behaviour. In addition, the interaction and sensing behaviour of CQDs for dopamine is also presented in this work with a detection limit of 0.2 mM. The steady state and time-resolved methods have been employed in fluorescence quenching methods for sensing dopamine through CQDs at room temperature. The bimolecular quenching rate constants for different concentration have been measured. The interaction between CQDs and dopamine indicates fluorescence quenching method is an elegant process for detecting dopamine through CQDs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Application of unsupervised deep learning to image segmentation and in-situ contact angle measurements in a CO 2 -water-rock system

Rock surface wettability is a critical property that regulates multiphase flows in porous media, which can be quantified using the surface contact angle (CA). X-ray micro-computed tomography (μCT) provides an effective approach to in-situ measurements of surface CAs. However, the CA measurement accuracy depends significantly on the quality of CT image segmentation, which is the clustering of CT pixels into separate phases. Inspired by this, we developed a deep learning (DL)-based CA measurement workflow. Motivated by the recent tremendous progress in unsupervised learning techniques and aiming to avoid expensive manual data annotations, an unsupervised DL pipeline for CT image segmentation was proposed and implemented, which includes unsupervised model training and post-processing. The unsupervised model training was driven by a novel loss function constrained with feature similarity and spatial continuity and implemented by iterative forward and backward paths; the former clustered the pixel-wise feature vectors extracted by convolution neural networks, whereas the latter updated the parameters using gradient descent. An over-segmentation strategy was adopted for model training. The post-processing steps based on agglomerative hierarchical clustering (AHC) were implemented to further merge the over-segmented model output to the desired cluster number, which is intended to improve the efficiency of image segmentation. The developed unsupervised DL pipeline was compared with other commonly-used image segmentation methods using pixel-wise and physics-based evaluation metrics on a synthetic raw-image dataset, which had a known ground truth. The unsupervised DL pipeline showed the best performance. Next, the segmented images were input to an automatic CA measurement tool, and the results were validated by comparisons with manual measurements. The CA values from the manual and automatic measurements showed similar distributions and statistical properties. The automatic measurement demonstrated a wider spectrum because of the much larger number of measurement data points. The primary novelty of the unsupervised DL pipeline developed in this study lies in the novel loss function and the over-segmentation strategy associated with AHC post-processing. Finally, the workflow has been proven an efficient tool for pore-scale wettability characterization, which has a wide range of applications in fundamental studies of multiphase flows in natural porous media, which have critical implications to geological carbon sequestration, hydrocarbon energy recovery, and contaminant transport in groundwater.

42 ENGINEERING↗

Femtosecond pulse parameter estimation from photoelectron momenta using machine learning

Abstract Deep learning models have provided huge interpretation power for image-like data. Specifically, convolutional neural networks (CNNs) have demonstrated incredible acuity for tasks such as feature extraction or parameter estimation. Here we test CNNs on strong-field ionization photoelectron spectra, training on theoretical data sets to ‘invert’ experimental data. Pulse characterization is used as a ‘testing ground’, specifically we retrieve the laser intensity, where ‘traditional’ measurements typically lead to 20% uncertainty. We report on crucial data augmentation techniques required to successfully train on theoretical data and return consistent results from experiments, including accounting for detector saturation. The same procedure can be repeated to apply CNNs in a range of scenarios for strong-field ionization. Using a predictive uncertainty estimation, reliable laser intensity uncertainties of a few percent can be extracted, which are consistently lower than those given by traditional techniques. Using interpretability methods can reveal parts of the distribution that are most sensitive to laser intensity, which can be directly associated with holographic interferences. The CNNs employed provide an accurate and convenient ways to extract parameters, and represent a novel interpretational tool for strong-field ionization spectra.

Szołdra, Tomasz (ORCID:0000000228970506)↗

Total Protein Analysis in Algae via Bulk Amino Acid Detection: Optimization of Amino Acid Derivatization after Hydrolysis with O -Phthalaldehyde 3-Mercaptopropionic Acid (OPA-3MPA)

The analysis of protein in algal biomass is one of the most critical areas of commercial development of algae characterization for nutritional or other high value applications. A new rapid and accurate method is required that can be widely implemented and that is free from interferences from the complex algal biomass matrix. We developed a simple spectrophotometric method for primary amino acid quantification bulk measurement in an acid hydrolyzed algal biomass preparation, as an alternative to the more labor-intensive amino HPLC acid analysis or less specific nitrogen-to-protein conversion. We have validated an O -phthalaldehyde (OPA)-based derivatization method, showing accurate and linear quantification for standard reference amino acids as well as mixtures, mimicking the amino acid complexity found in algal biomass. The presence of interferences that may be derived from the complex biomass biochemical composition was tested during the method validation phase. We document the application of a novel method of OPA derivatization with 3-mercaptopropionic acid (3MPA) to determine the total amino acid content of harvested algal biomass collected from different, controlled cultivation conditions and demonstrated a within 10% accuracy against a reference measurement of amino acid content in at least 4 species and 10 algal biomass samples, across early, mid, and late-stages of cultivation.

09 BIOMASS FUELS↗

Grafting density effects, optoelectrical properties and nano-patterning of poly(para-phenylene) brushes

Well-defined conjugated polymers in confined geometries are challenging to synthesize and characterize, yet they are potentially useful in a broad range of organic optoelectronic devices such as transistors, light emitting diodes, solar cells, sensors, and nanocircuits. We report a systematic study of optoelectrical properties, grafting density effects, and nanopatterning of a model, end-tethered conjugated polymer system. Specifically, poly(para-phenylene) (PPP) brushes of various grafting density are created in situ by aromatizing well-defined, end-tethered poly(1,3-cyclohexadiene) (PCHD) “precursor brushes”. Furthermore, this novel precursor brush approach provides a convenient way to make and systematically control the grafting density of high molecular weight conjugated polymer brushes that would otherwise be insoluble. Finally, this allows us to examine how grafting density impacts the effective conjugation length of the conjugated PPP brushes and to adapt the fabrication method to develop spatially patterned conjugated brush systems, which is important for practical applications of conjugated polymer brushes.

36 MATERIALS SCIENCE↗

Advanced Atmospheric Ensemble Modeling Techniques

Ensemble modeling (EM), the creation of multiple atmospheric simulations for a given time period, has become an essential tool for characterizing uncertainties in model predictions. We explore two novel ensemble modeling techniques: (1) perturbation of model parameters (Adaptive Programming, AP), and (2) data assimilation (Ensemble Kalman Filter, EnKF). The current research is an extension to work from last year and examines transport on a small spatial scale (<100 km) in complex terrain, for more rigorous testing of the ensemble technique. Two different release cases were studied, a coastal release (SF6) and an inland release (Freon) which consisted of two release times. Observations of tracer concentration and meteorology are used to judge the ensemble results. In addition, adaptive grid techniques have been developed to reduce required computing resources for transport calculations. Using a 20- member ensemble, the standard approach generated downwind transport that was quantitatively good for both releases; however, the EnKF method produced additional improvement for the coastal release where the spatial and temporal differences due to interior valley heating lead to the inland movement of the plume. The AP technique showed improvements for both release cases, with more improvement shown in the inland release. This research demonstrated that transport accuracy can be improved when models are adapted to a particular location/time or when important local data is assimilated into the simulation and enhances SRNL’s capability in atmospheric transport modeling in support of its current customer base and local site missions, as well as our ability to attract new customers within the intelligence community.

54 ENVIRONMENTAL SCIENCES↗

Thermal Storage Glass Development

Halotechnics, Inc.develops novel high temperature fluids and phase change materials, and designs modular salt storage tanks, as well as full thermal systems, for waste heat capture, grid-scale electricity storage, concentrated solar power, and other energy and efficiency applications. Using combinatorial chemistry techniques, Halotechnics has developed a variety of salts and other oxide compositions. Halotechnics’s molten fluids product line offers salt and oxide glass products that can be used in temperature ranges spanning from 50°C to 1200°C. The properties of these various materials are appropriate for both sensible heat and latent heat thermal energy storage applications. The thermal energy stored in the materials can be converted to electricity by various methods, including direct conversion using thermoelectric generation, or indirectly, by heating steam and running a turbine. LBL has materials characterization equipment that is useful for Halotechnics to achieve its materials development goals. Through the CalCharge agreement with LBL, Halotechnics worked with an LBL principal investigator to access this equipment, and to jointly design experimental procedures for unusual measurements.

25 ENERGY STORAGE↗

Lightweight Lidar Telescopes for Space Applications

NASA is intent on exploiting the unique perspective of space-based remote optical instruments to observe and study large-scale environmental processes. Emphasis on smaller and more affordable missions continues to force the remote sensing instruments to find innovative ways to reduce the size, weight, and cost of the sensor package. This is a challenge because many of the proposed instruments incorporate a high quality meter-class telescope that can be a significant driver of total instrument costs. While various methods for telescope weight reduction have been achieved, many of the current approaches rely on exotic materials and specialized manufacturing techniques that limit availability or substantially increase costs. A competitive lightweight telescope technology that is especially well suited to space-based coherent Doppler wind lidar has been developed through a collaborative effort involving NASA Marshall Space Flight Center (MSFC) through the Global Hydrology and Climate Center (GHCC) and the University of Alabama in Huntsville (UAH) at the Center for Applied Optics (CAO). The new lightweight optics using metal alloy shells and surfaces (LOMASS) fabrication approach is suitable for high quality metal mirrors and meter-class telescopes. Compared to alternative materials and fabrication methods the new approach promises to reduce the areal density of a meter-class telescope to less than 15-kg/sq m; deliver a minimum VIO-RMS surface optical quality; while using commercial materials and equipment to lower procurement costs. The final optical figure and finish is put into the mirrors through conventional diamond turning and polishing techniques. This approach is especially advantageous for a coherent lidar instrument because the reduced telescope weight permits the rotation of the telescope to scan the beam without requiring heavy wedges or additional large mirrors. Ongoing investigations and preliminary results show promise for the LOMASS approach to be successful in demonstrating a novel alternative approach to fabricating lightweight mirrors with performance parameters comparable with the Space Readiness Coherent Lidar Experiment (SPARCLE). Development and process characterization is continuing with the design and fabrication of mirrors for a 25-cm telescope suitable for a lidar instrument.

Peters, Bruce R.↗

Preparation and characterization of poly (arylene ether isoxazole)s by fluoride ion-mediated aromatic nucleophilic displacement reactions

As part of a continuing effort to prepare novel thermally stable high-performance polymers, poly(arylene ether isoxazole)s have been prepared by fluoride ion-catalyzed aromatic nucleophilic substitution reactions with bis(trimethylsiloxyphenyl) isoxazoles and activated bisarylhalides in diphenyl sulfone. Initial investigation involving the preparation of these materials with isoxazole bisphenols and activated bisarylhalides in the presence of potassium carbonate indicated that, under reaction conditions necessary to prepare high-molecular-weight materials, the isoxazole monomer was converted to an enamino ketone. This side reaction was avoided by using fluoride as a base. However, trimethylsilyl ether derivatives of the isoxazole bisphenols were required in these polymerizations for the preparation of high-molecular-weight materials. Moderate to high inherent viscosity eta(sub inh): 0.43-0.87 dl/g) materials with good thermal stability (air: 409-477 C, helium: 435-512 C) can be prepared by the silyl ether method. Glass transition temperatures ranged from 182 to 225 C for polymers with phenyl pendants and from 170 to 214 C for those without. Molecular weight control by 2% endcapping and the incorporation of a phenyl pendant at the 4 position of the isoxazole is necessary to yield polymers soluble in polar aprotic solvents at room temperature. There is evidence, however, indicating the existence of crosslinks between the polymer chains when the silyl ether approach is utilized.

Herbert, C. G.↗

Rarefied gas flow in a rectangular enclosure induced by non-isothermal walls

The flow of a rarefied gas in a rectangular enclosure due to the non-isothermal walls with no synergetic contributions from external force fields is investigated. The top and bottom walls are maintained at constant but different temperatures and along the lateral walls a linear temperature profile is assumed. Modeling is based on the direct numerical solution of the Shakhov kinetic equation and the Direct Simulation Monte Carlo (DSMC) method. Solving the problem both deterministically and stochastically allows a systematic comparison and verification of the results as well as the exploitation of the numerical advantages of each approach in the investigation of the involved flow and heat transfer phenomena. The thermally induced flow is simulated in terms of three dimensionless parameters characterizing the problem, namely, the reference Knudsen number, the temperature ratio of the bottom over the top plates, and the enclosure aspect ratio. Their effect on the flow configuration and bulk quantities is thoroughly examined. Along the side walls, the gas flows at small Knudsen numbers from cold-to-hot, while as the Knudsen number is increased the gas flows from hot-to-cold and the thermally induced flow configuration becomes more complex. These flow patterns with the hot-to-cold flow to be extended to the whole length of the non-isothermal side walls may exist even at small temperature differences and then, they are enhanced as the temperature difference between the top and bottom plates is increased. The cavity aspect ratio also influences this flow configuration and the hot-to-cold flow is becoming more dominant as the depth compared to the width of the cavity is increased. To further analyze the flow patterns a novel solution decomposition into ballistic and collision parts is introduced. This is achieved by accordingly modifying the indexing process of the typical DSMC algorithm. The contribution of each part of the solution is separately examined and a physical interpretation of the flow configuration, including the hot-to-cold flow close to the side walls, in the whole range of the Knudsen number is provided.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synthesis of high efficient Ca{sub 2}SiO{sub 4}:Eu{sup 2+} green emitting phosphor by a liquid phase precursor method

Green emitting Eu{sup 2+}-doped Ca{sub 2}SiO{sub 4} phosphors were synthesized by three different methods (a conventional solid state reaction (SSR) method, a novel liquid phase precursor approach using SiO{sub 2} sol (LPP-SiO{sub 2}(sol)) and water-soluble silicon compound (LPP-WSS)). The obtained phosphors exhibited a broad excitation spectrum ranging from 225 to 450 nm and a strong green emission peak at 502 nm due to the 4f{sup 6}5d{sup 1}{yields}4f{sup 7}({sup 8}S{sub 7/2}) transition of Eu{sup 2+}. The highest luminescent intensity was obtained for the samples fired at 1100 Degree-Sign C. The dependence of luminescence properties on Eu{sup 2+} concentration for the phosphors synthesized using LPP-WSS method was also examined from 0.1 to 5.0 mol% and the maximum emission intensity was observed at 3.0 mol% Eu{sup 2+}. A detailed analysis using various characterizations revealed that phosphors produced by the LPP-WSS process exhibited more homogenous phase distribution and higher luminescence intensity than those from the other two processes, which suggested the potential application of Ca{sub 2}SiO{sub 4}:Eu{sup 2+} in white light-emitting diodes and fluorescence lamps. - Graphical abstract: The synthesis of Eu{sup 2+} doped Ca{sub 2}SiO{sub 4} green emitting phosphors were carried out using LPP-SiO{sub 2}(sol), LPP-WSS and SSR methods. The adequate reaction of starting materials base on solution mixing and cellulose impregnating during LPP-WSS procedure resulted in single crystalline structure as well as fine morphology, and finally determined a superior luminescent intensity. Highlights: Black-Right-Pointing-Pointer Ca{sub 2}SiO{sub 4}:Eu{sup 2+} phosphor was synthesized by three methods (SSR, LPP-SiO{sub 2} and LPP-WSS). Black-Right-Pointing-Pointer Effect of different processes on the property of phosphor was studied. Black-Right-Pointing-Pointer Phosphor produced by LPP-WSS showed better homogenous phase and fluorescent property. Black-Right-Pointing-Pointer LPP-WSS approach was identified as the best method among these three approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low cost fabrication of highly sensitive ethanol sensor based on Pd-doped α-Fe2O3 porous nanotubes

Highlights: • Novel porous tubular nanostructures of α-Fe{sub 2}O{sub 3} are proposed. • The sensor based on 3.0 wt% Pd-doped α-Fe{sub 2}O{sub 3} porous nanotubes exhibited superior gas-sensing properties to ethanol. • The detection limit of the sensor for ethanol gas is as low as 0.1 ppm at 240 °C. • The sensor possesses an excellent reproducibility and good linearity (0.1–400 ppm) in ethanol detection. - Abstract: Pure and Pd-doped α-Fe{sub 2}O{sub 3} porous nanotubes (PNTs) are synthesized by a facile electrospinning approach. Different Pd dopant concentrations are introduced to investigate the dopant’s role in sensing performance. The structures and chemical compositions of the as-prepared products are examined using a series of characterization methods including XRD, EDS, SEM, TEM, XPS and BET. The gas-sensing properties of the sensor based on above PNTs are studied. And the results reveal that, compared with pure α-Fe{sub 2}O{sub 3}, the 3.0 wt% Pd-doped α-Fe{sub 2}O{sub 3} PNTs sensors exhibit superior performance in ethanol detection (at 240 °C). The highest sensitivity reaches 65.4 for 50 ppm ethanol and the detection limit is as low as 0.1 ppm. In addition, the sensors also show excellent selectivity, good long-term stability and as well as rapid response/recovery time (8 s/30 s, respectively) to ethanol. The improvement of sensing performance is mainly attributed to the dramatic sensitization of the additional Pd components.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Wave Energy Power Take-off Validation with a Hydraulicly Actuated Rotary Dynamometer and a Bi-Directional High-Power DC Supply

There are many organizations working towards the commercialization of wave energy converter technologies and are advancing their designs through the technology readiness levels (TRLs). A critical step before the field deployment of prototype wave energy converters is the validation of the subsystems and components that are contained in the wave energy converter through laboratory testing and performance characterization. In 2021, the National Renewable Energy Laboratory (NREL) developed and demonstrated a system for testing power takeoffs (PTO) with a low-speed, high-torque dynamometer and a grid-tied high-power DC power source and sink before field deployment. The hydraulic dynamometer allows for the simulation of PTO actuation from wave motion and is capable of a wide range of wave periods and heights which are represented as various speeds and torques from the dynamometer. The high-power bidirectional power supply allows for hardware in the loop and controller in the loop testing to be conducted on WEC power electronics. This presentation was made to describe the methods used by NREL research staff to test all components and sub-systems in the PTO of a novel wave energy converter before field deployment.

dynamometer↗

Wave Energy Power Take-Off Validation with a Hydraulicly Actuated Rotary Dynamometer and a Bidirectional High-Power DC Supply: Preprint

There are many organizations working towards the commercialization of wave energy converter technologies and are advancing their designs through the technology readiness levels (TRLs). A critical step before the field deployment of prototype wave energy converters is the validation of the subsystems and components that are contained in the wave energy converter through laboratory testing and performance characterization. In 2021, the National Renewable Energy Laboratory (NREL) developed and demonstrated a system for testing power takeoffs (PTO) with a low-speed, high-torque dynamometer and a grid-tied high-power DC power source and sink before field deployment. The hydraulic dynamometer allows for the simulation of PTO actuation from wave motion and is capable of a wide range of wave periods and heights which are represented as various speeds and torques from the dynamometer. The high-power bidirectional power supply allows for hardware in the loop and controller in the loop testing to be conducted on WEC power electronics. This presentation was made to describe the methods used by NREL research staff to test all components and sub-systems in the PTO of a novel wave energy converter before field deployment.

dynamometer↗

Toward in vivo lung's tissue incompressibility characterization for tumor motion modeling in radiation therapy

Purpose: A novel technique is proposed to characterize lung tissue incompressibility variation during respiration. Estimating lung tissue incompressibility parameter variations resulting from air content variation throughout respiration is critical for computer assisted tumor motion tracking. Continuous tumor motion is a major challenge in lung cancer radiotherapy, especially with external beam radiotherapy. If not accounted for, this motion may lead to areas of radiation overdosage for normal tissue. Given the unavailability of imaging modality that can be used effectively for real-time lung tumor tracking, computer assisted approach based on tissue deformation estimation can be a good alternative. This approach involves lung biomechanical model where its fidelity depends on input tissue properties. This investigation shows that considering variable tissue incompressibility parameter is very important for predicting tumor motion accurately, hence improving the lung radiotherapy outcome. Methods: First, an in silico lung phantom study was conducted to demonstrate the importance of employing variable Poisson's ratio for tumor motion predication. After it was established that modeling this variability is critical for accurate tumor motion prediction, an optimization based technique was developed to estimate lung tissue Poisson's ratio as a function of respiration cycle time. In this technique, the Poisson's ratio and lung pressure value were varied systematically until optimal values were obtained, leading to maximum similarity between acquired and simulated 4D CT lung images. This technique was applied in an ex vivo porcine lung study where simulated images were constructed using the end exhale CT image and deformation fields obtained from the lung's FE modeling of each respiration time increment. To model the tissue, linear elastic and Marlow hyperelastic material models in conjunction with variable Poisson's ratio were used. Results: The phantom study showed that the tumor motion trajectory and its final locations obtained from simulations with and without considering tissue incompressibility variation were very different. For example, tumor displacements in the z direction were -11.23 and -38.10 mm obtained with the Marlow hyperelastic material model in conjunction with constant and variable Poisson's ratio, respectively. By comparing the acquired 4D-CT image sequence of the porcine lung with their image sequence counterparts obtained from the hyperelastic model with constant and variable Poisson's ratio, it was shown that using variable tissue incompressibility reduced errors significantly in tumor motion prediction. Conclusions: This investigation demonstrates the importance of incompressibility variation estimation and utilization for accurate tumor tracking in computer assisted lung external beam radiation therapy. An optimization framework was developed to estimate a Poisson's ratio function in terms of respiration cycle time using experimental image data of the lung. Utilizing this function along with respiratory system FE modeling may lead to more effective tumor targeting, hence potentially improving the outcome of lung external beam radiation therapy techniques. This is particularly true for stereotactic body radiation therapy where only one or a few fraction treatments are applied, precluding the possibility of averaging out dosimetric deviations introduced by the respiratory motion.

60 APPLIED LIFE SCIENCES↗

SUBTASK 1.6 – BASIN ELECTRIC CARBON STORAGE RESEARCH PROJECT: NOVEL MONITORING TECHNIQUES

The Energy & Environmental Research Center (EERC) conducted baseline activities associated with an applied research project at Basin Electric Power Cooperative’s (Basin’s) carbon capture and storage (CCS) site in Beulah, North Dakota, to establish novel carbon storage-monitoring techniques as commercial methods under Cooperative Agreement No. DE-FE0024233, Subtask 1.6. The following report summarizes the baseline activities performed and briefly describes the subsequent (operational monitoring) activities that have been proposed to the U.S. Department of Energy (DOE) as part of the overall project to develop and demonstrate novel monitoring techniques at North America’s largest permitted CCS operation. Dakota Gasification Company (DGC), a wholly owned subsidiary of Basin, owns and operates the Great Plains Synfuels Plant (GPSP) approximately 5 miles northwest of the town of Beulah, North Dakota (Figure 1). In 2023, DGC received approval from the North Dakota Industrial Commission (NDIC) to develop a storage facility on-site for injecting a stream of carbon dioxide (CO2) captured from GPSP. DGC will transport the captured CO2 stream with approximately 6.8 miles of transmission lines that extend north of GPSP and inject >1 million tonnes (MMt) of CO2 annually (>1 MMt/yr) over a 12-year period with up to six underground injection control (UIC) Class VI-compliant injection wells completed in the Broom Creek Formation, a predominantly sandstone reservoir and saline aquifer underlying GPSP. The Broom Creek Formation lies approximately 5900 feet (ft) below ground surface (bgs) at GPSP. The commercial scale (i.e., >1 MMt/yr) of DGC’s permitted carbon storage project is ideal for developing and testing the novel monitoring techniques included within Subtask 1.6. The goals of this project are to demonstrate 1) the cost-effectiveness of novel monitoring technologies included as part of this research, 2) technology capability for tracking the CO2 plume and/or associated pressure response in the subsurface and monitoring out-of-zone migration, and 3) compliance with UIC Class VI program requirements. The research activities proposed for the overall project include 1) design of an automated, integrated, modular (AIM) monitoring station; 2) time-lapse electromagnetic (EM) field surveys; 3) drone-based surveillance studies; 4) time-lapse monitoring with seismic methods; 5) advanced wellbore-monitoring methods; 6) deployment of an AIM monitoring network; 7) EM monitoring of CO2 with real-time data processing; 8) continued seasonal drone-based surveillance studies; 9) seismic monitoring with passive and active surveys; and 10) wellbore monitoring with nuclear magnetic resonance (NMR) for near-surface characterization. Completion of Activities 1.0–5.0 (baseline activities) are described in this report. Upon authorization of funding by DOE, the EERC will initiate Activities 6.0– 10.0 (operational monitoring activities). Current state-of-the-art (SOA) carbon storage-monitoring techniques require countless labor hours dedicated to the acquisition of data. Once data are gathered, these SOA techniques often rely on commercial facilities to process raw data from the field. However, it is anticipated that next-generation monitoring techniques, such as those being demonstrated, will lower acquisition footprints, be less operationally intensive, and improve data acquisition efficiencies. These new techniques are more conducive to the application of machine learning, artificial intelligence, and automation, thus providing a pathway for integration into active control systems, informing site operability, and improving the integration of data for future CCS projects across the United States. Additionally, reclaimed and active mining lands are present within the project site, creating a unique opportunity to demonstrate the effectiveness of remote sensing and surface-based geophysics monitoring techniques at similar project sites that may include disturbed, unconsolidated, or actively excavated near-surface environments. The efforts included in the overall project will produce necessary designs, learnings, and data acquired during the baseline and operational monitoring periods that are necessary for time-lapse demonstration and validation of the described monitoring techniques. In addition, it is anticipated that the monitoring technologies included in this study will be compliant with UIC Class VI requirements to enable the potential for implementation at other CCS sites across the United States.

42 ENGINEERING↗

SU-C-204-06: Monte Carlo Dose Calculation for Kilovoltage X-Ray-Psoralen Activated Cancer Therapy (X-PACT): Preliminary Results

Purpose: X-PACT is an experimental cancer therapy where kV x-rays are used to photo-activate anti-cancer therapeutics through phosphor intermediaries (phosphors that absorb x-rays and re-radiate as UV light). Clinical trials in pet dogs are currently underway (NC State College of Veterinary Medicine) and an essential component is the ability to model the kV dose in these dogs. Here we report the commissioning and characterization of a Monte Carlo (MC) treatment planning simulation tool to calculate X-PACT radiation doses in canine trials. Methods: FLUKA multi-particle MC simulation package was used to simulate a standard X-PACT radiation treatment beam of 80kVp with the Varian OBI x-ray source geometry. The beam quality was verified by comparing measured and simulated attenuation of the beam by various thicknesses of aluminum (2–4.6 mm) under narrow beam conditions (HVL). The beam parameters at commissioning were then corroborated using MC, characterized and verified with empirically collected commissioning data, including: percent depth dose curves (PDD), back-scatter factors (BSF), collimator scatter factor(s), and heel effect, etc. All simulations were conducted for N=30M histories at M=100 iterations. Results: HVL and PDD simulation data agreed with an average percent error of 2.42%±0.33 and 6.03%±1.58, respectively. The mean square error (MSE) values for HVL and PDD (0.07% and 0.50%) were low, as expected; however, longer simulations are required to validate convergence to the expected values. Qualitatively, pre- and post-filtration source spectra matched well with 80kVp references generated via SPEKTR software. Further validation of commissioning data simulation is underway in preparation for first-time 3D dose calculations with canine CBCT data. Conclusion: We have prepared a Monte Carlo simulation capable of accurate dose calculation for use with ongoing X-PACT canine clinical trials. Preliminary results show good agreement with measured data and hold promise for accurate quantification of dose for this novel psoralen X-ray therapy. Funding Support, Disclosures, & Conflict of Interest: The Monte Carlo simulation work was not funded; Drs. Adamson & Oldham have received funding from Immunolight LLC for X-PACT research.

60 APPLIED LIFE SCIENCES↗