Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operation optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

MULTI-CORE AND OPTICAL PROCESSOR RELATED APPLICATIONS RESEARCH AT OAK RIDGE NATIONAL LABORATORY

High-speed parallelization of common tasks holds great promise as a low-risk approach to achieving the significant increases in signal processing and computational performance required for next generation innovations in reconfigurable radio systems. Researchers at the Oak Ridge National Laboratory have been working on exploiting the parallelization offered by this emerging technology and applying it to a variety of problems. This paper will highlight recent experience with four different parallel processors applied to signal processing tasks that are directly relevant to signal processing required for SDR/CR waveforms. The first is the EnLight Optical Core Processor applied to matched filter (MF) correlation processing via fast Fourier transform (FFT) of broadband Dopplersensitive waveforms (DSW) using active sonar arrays for target tracking. The second is the IBM CELL Broadband Engine applied to 2-D discrete Fourier transform (DFT) kernel for image processing and frequency domain processing. And the third is the NVIDIA graphical processor applied to document feature clustering. EnLight Optical Core Processor. Optical processing is inherently capable of high-parallelism that can be translated to very high performance, low power dissipation computing. The EnLight 256 is a small form factor signal processing chip (5x5 cm2) with a digital optical core that is being developed by an Israeli startup company. As part of its evaluation of foreign technology, ORNL's Center for Engineering Science Advanced Research (CESAR) had access to a precursor EnLight 64 Alpha hardware for a preliminary assessment of capabilities in terms of large Fourier transforms for matched filter banks and on applications related to Doppler-sensitive waveforms. This processor is optimized for array operations, which it performs in fixed-point arithmetic at the rate of 16 TeraOPS at 8-bit precision. This is approximately 1000 times faster than the fastest DSP available today. The optical core performs the matrix-vector multiplications, where the nominal matrix size is 256x256. The system clock is 125MHz. At each clock cycle, 128K multiply-and-add operations per second (OPS) are carried out, which yields a peak performance of 16 TeraOPS. IBM Cell Broadband Engine. The Cell processor is the extraordinary resulting product of 5 years of sustained, intensive R&D collaboration (involving over $400M investment) between IBM, Sony, and Toshiba. Its architecture comprises one multithreaded 64-bit PowerPC processor element (PPE) with VMX capabilities and two levels of globally coherent cache, and 8 synergistic processor elements (SPEs). Each SPE consists of a processor (SPU) designed for streaming workloads, local memory, and a globally coherent direct memory access (DMA) engine. Computations are performed in 128-bit wide single instruction multiple data streams (SIMD). An integrated high-bandwidth element interconnect bus (EIB) connects the nine processors and their ports to external memory and to system I/O. The Applied Software Engineering Research (ASER) Group at the ORNL is applying the Cell to a variety of text and image analysis applications. Research on Cell-equipped PlayStation3 (PS3) consoles has led to the development of a correlation-based image recognition engine that enables a single PS3 to process images at more than 10X the speed of state-of-the-art single-core processors. NVIDIA Graphics Processing Units. The ASER group is also employing the latest NVIDIA graphical processing units (GPUs) to accelerate clustering of thousands of text documents using recently developed clustering algorithms such as document flocking and affinity propagation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Instrumentation and Control and Human Machine Interface Science and Technology Roadmap in Support of Advanced Reactors and Fuel Programs in the U.S.

The purpose of this paper is to provide an overview of the current status of the Instrumentation, Control and Human Machine Interface (ICHMI) Science and Technology Roadmap (Reference xi) that was developed to address the major challenges in this technical area for the Gen IV and other U.S. Department of Energy (DOE) initiatives that support future deployments of nuclear energy systems. Reliable, capable ICHMI systems will be necessary for the advanced nuclear plants to be economically competitive. ICHMI enables measurement, control, protection, monitoring, and maintenance for processes and components. Through improvements in the technologies and demonstration of their use to facilitate licensing, ICHMI can contribute to the reduction of plant operations and maintenance costs while helping to ensure high plant availability. The impact of ICHMI can be achieved through effective use of the technologies to improve operational efficiency and optimize use of human resources. However, current licensing experience with digital I&C systems has provided lessons learned concerning the difficulties that can be encountered when introducing advanced technologies with expanded capabilities. Thus, in the development of advanced nuclear power designs, it will be important to address both the technical foundations of ICHMI systems and their licensing considerations. The ICHMI roadmap will identify the necessary research, development and demonstration activities that are essential to facilitate necessary technology advancement and resolve outstanding issues.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensor Data Processing for Tracking Underwater Threats Using Terascale Optical Core Devices

A critical aspect of littoral surveillance (including port protection) involves the localization and tracking of underwater threats such as manned or unmanned autonomous underwater vehicles. In this article, we present a methodology for locating underwater threat sources from uncertain sensor network data, and illustrate the threat tracking aspects using active sonars in a matched filter framework. The novelty of the latter paradigm lies in its implementation on a tera-scale optical core processor, EnLight , recently introduced by Lenslet Laboratories. This processor is optimized for array operations, which it performs in a fixed point arithmetic architecture at tera-scale throughput. Using the EnLight 64 prototype processor, our results (i) illustrate the ability to reach a robust tracking accuracy, and (ii) demonstrate that a considerable speed-up (a factor of over 13,000) can be achieved when compared to an Intel XeonTM processor in the computation of sets of 80K-sample complex Fourier transforms that are associated with our matched filter techniques.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

HYPSTAT (Hydrogen Production, Storage, and Transmission Analysis Tool) [SWR-23-04]

The Hydrogen Production, Storage, and Transmission Analysis Tool (HYPSTAT) is a modeling framework developed by the National Renewable Energy Laboratory (NREL) to support the analysis of hydrogen systems. HYPSTAT focuses on key components of hydrogen infrastructure, particularly electrolytic hydrogen production, hydrogen storage, and hydrogen transmission, as part of the transition to decarbonized energy systems HYPSTAT operates as a supply-to-demand model, taking a fixed exogenous demand as input and optimizing the design and operation of the hydrogen system to meet that demand. It determines cost-optimal configurations based on specified technology options and system constraints.

Brauch, Joseph [National Renewable Energy Laborato↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System

Frequency control from photovoltaic (PV) power plants has great potential to address the frequency response challenge of the power system with high penetrations of renewable generation. Using model-based approaches to determine the optimal PV headroom reserve, however, requires significant online computation and is intractable for an interconnection level system. This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal PV reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. Furthermore, the proposed reserve determination strategy is applied on a realistic 1-day operation profile of the WECC system and demonstrates a savings of more than 40% PV headroom compared to a conservative approach. It is evident that the proposed strategy can efficiently and effectively determine the optimal PV frequency control reserve for realistic interconnection systems.

frequency control↗

Operation of Natural Gas Pipeline Networks With Storage Under Transient Flow Conditions

Here, we formulate a nonlinear optimal control problem for intraday operation of a natural gas pipeline network that includes storage reservoirs. The dynamics of compressible gas flow through pipes, compressors, reservoirs, and wells are considered. In particular, a reservoir is modeled as a rigid, hollow container that stores gas under isothermal conditions and uniform density, and a well is modeled as a vertical pipe. For each pipe, flow dynamics are described by a coupled partial differential equation (PDE) system in density and mass flux variables, with momentum dissipation modeled using the Darcy–Wiesbach friction approximation. Compressors are modeled as scaling up the pressure of gas between the inlet and outlet. The governing equations for all network components are spatially discretized and assembled into a nonlinear differential-algebraic equation (DAE) system, which synthesizes above-ground pipeline and subsurface reservoir dynamics into a single reduced-order model. We seek to maximize an objective function that quantifies economic profit and network efficiency subject to the flow equations and inequalities that represent operating limitations. The problem is solved using a primal–dual interior point solver, and the solutions are validated in computational experiments and simulations on several pipeline test networks to demonstrate the effectiveness of the proposed methodology.

03 NATURAL GAS↗

Performance of sweeping gas membrane distillation for treating produced water: Modeling and experiments

Membrane distillation (MD) has shown promise for desalination of produced water (PW), but there are very few studies reported on the performance of MD with real PW and the characteristics of the fouling and scaling in MD. Among different MD configurations, sweeping gas MD (SGMD) is the least studied configuration. Here we report the application of SGMD for treating high-salinity PW (123 g L -1 ). The SGMD operating conditions were first carefully optimized through pure water MD experiments by varying operating conditions. The flux evaluation was accompanied by a detailed Aspen Custom Modeler simulation based on the electrolyte-NRTL thermodynamic model to better understand the heat and mass transfer in the feed and permeate channel. Supported by experiments, modeling results confirmed the partial condensation of the vapor in the permeate channel. Furthermore, it was concluded that the saturation of the sweeping gas is controlling the overall mass transfer through the membrane. Selected membranes and optimized conditions were then used to conduct short-term and long-term performance tests with PW. In long-term MD test, the concentration of the PW increased by a factor of two (50% water recovery), while the membrane exhibited small flux decline. Elemental analysis showed that strontium and sodium were the major scalant compounds.

42 ENGINEERING↗

Utility-Scale Shared Energy Storage Deployment: Challenges, Research Gaps, and Opportunities

Although community energy storage (CES) and behind-the-meter (BTM) energy storage systems have been widely used to offer homeowners and communities a variety of localized benefits, their scalability and grid support functionalities are limited. On the other hand, utility-scale shared energy storage (USES) systems may offer a number of benefits for grid integration, scalability, and economic viability. When compared to BTM and CES alternatives, these large-scale systems provide more storage capacity, more efficient operations, and more economically viable options. The deployment of USES presents opportunities for optimizing grid performance, integrating renewable energy resources, and improving energy security at the community level. However, significant research gaps exist in optimizing the integration and operation of these systems, especially to allocate energy for consumer use, grid services, and enhancing energy resilience. This paper reviews the literature in this regard, focusing on the opportunities, research gaps, and challenges associated with USES deployment. Firstly, the paper provides an overview of USES systems and emphasizes their benefits. Secondly, the key challenges are identified, and research gaps associated with the operation and integration of these systems are highlighted. Lastly, some potential solutions and opportunities that can be adopted to facilitate the rapid deployment and management of USES are presented. Technological, economic, regulatory, and environmental aspects are also discussed in this paper, providing an overview of the current state and future prospects of this technology.

Gautam, Mukesh [BATTELLE (PACIFIC NW LAB)] (ORCID:↗

Pump-and-Treat Impacts on Aquifer Conditions and the Development of System-Wide Performance Strategies - 20377

The pump-and-treat (P and T) system on the Hanford Site's Central Plateau currently treats multiple contaminants within the 200-ZP-1 operable unit, including nitrate through its biological treatment processes. Although it was initially designed to support the 200-ZP-1 Remedial Action Objectives, the P and T system has evolved in use to address contaminants from other regions of the aquifer as well. The P and T influents are biogeochemically distinct, treating groundwaters with elevated concentrations of cyanide, uranium, technetium-99, and nitrate. Given the varying geochemical signatures from current and potential future sources, operational conditions, and amendments considered for treatment processes, there is a need to identify the impacts that the P and T effluent has on the aquifer, and how the aquifer affects P and T performance. To this end, laboratory efforts have focused on characterizing P and T effluent and its biogeochemical effects on the sediments through a series repacked column experiments. The P and T effluent is rich in particulate matter. A systematic inspection of this particulate matter in the P and T effluent showed significant levels of manganese/iron oxides, calcite crystals, relatively large organic matter molecules, and biomass. Therefore, the column experiments were designed and conducted for four different treatment systems: artificial groundwater, filtered P and T effluent, non-filtered P and T effluent, and chlorinated P and T effluent. Different levels of microbiologically- and geochemically-induced changes in the columns occurred and modified the flow systems. For example, physical filtration occurred in the sediments where the particulate material had accumulated in the top portion of the column. Reactive transport modeling of the laboratory experiments is being carried out so that the reaction network can be extrapolated to the field scale. These simulations will provide predictive evaluations of system performance based on P and T operational changes and aquifer mass loading and capacity estimates. This information can be used to address combined subsurface and operational challenges, such as the need for frequent well redevelopment to maintain injection capacity. This information also provides the technical basis for decisions related to the P and T system operations that support remedy optimization efforts and short- and long-term remedy decisions related to multiple operable units on the Hanford Site Central Plateau. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of membrane characteristics on the performance and cycling of the Br-2-H-2 redox flow cell

The Br-2/H-2 redox flow cell shows promise as a high-power, low-cost energy storage device. In this paper, the effect of various aspects of material selection and processing of proton exchange membranes on the operation of the Br-2/H-2 redox flow cell is determined. Membrane properties have a significant impact on the performance and efficiency of the system. In particular, there is a tradeoff between conductivity and crossover, where conductivity limits system efficiency at high current density and crossover limits efficiency at low current density. The impact of thickness, pretreatment procedure, swelling state during cell assembly, equivalent weight, membrane reinforcement, and addition of a microporous separator layer on this tradeoff is assessed. NR212 (50 mu m) pretreated by soaking in 70 degrees C water is found to be optimal for the studied operating conditions. For this case, an energy efficiency of greater than 75% is achieved for current density up to 400 mA cm(-2), with a maximum obtainable energy efficiency of 88%. A cell with this membrane was cycled continuously for 3164 h. Membrane transport properties, including conductivity and bromine and water crossover, were found to decrease moderately upon cycling but remained higher than those for the as-received membrane. (C) 2015 Elsevier B.V. All rights reserved.

Tucker, MC↗

Performance of a Natural Gas Solid Oxide Fuel Cell System With and Without Carbon Capture

The fuel cell program at the United States Department of Energy (DOE) National Energy Technology Laboratory (NETL) is focused on the development of low-cost, highly efficient, and reliable fossil-fuel-based solid oxide fuel cell (SOFC) power systems that can generate environmentally-friendly electric power with at least 90 percent carbon capture. NETL’s SOFC technology development roadmap is aligned with near-term market opportunities in the distributed generation sector to validate and advance the technology while paving the way for utility-scale natural gas (NG)- and coal-derived synthesis gas-fueled applications via progressively larger system demonstrations. The present study represents a part of a series of system evaluations being carried out at NETL to aid in prioritizing technological advances along research pathways to the realization of utility-scale SOFC systems, a transformational goal of the fuel cell program. In particular, the system performance of utility-scale NG fuel cell (NGFC) systems with and without carbon dioxide (CO2) capture is presented. The NGFC system analyzed features an external auto-thermal reformer (ATR) feeding the fuel to the SOFC system consisting of planar anode-supported SOFC with separated anode and cathode off-gas streams. In systems with CO2 capture, an air separation unit (ASU) is used to provide the oxygen for the ATR and for the combustion of unutilized fuel in the SOFC anode exhaust along with a CO2 purification unit to provide a nearly pure CO2 stream suitable for transport for usage in enhanced oil recovery operations or for storage in underground saline formations. Remaining thermal energy in the exhaust gases is recovered in a bottoming steam Rankine cycle while supplying any process heat requirements. A reduced order model (ROM) developed at the Pacific Northwest National Laboratory (PNNL) is used to predict the SOFC performance. The ROM, while being computationally effective for system studies, provides other detailed information about the state of the stack, such as the internal temperature gradient, generally not available from simple performance models often used to represent the SOFC. Such additional information can be important in system optimization studies to preclude operation under off-design conditions that can adversely impact overall system reliability. The NGFC system performance was analyzed by varying salient system parameters, including the percent of internal (to the SOFC module) NG reformation—ranging from 0 to 100 percent—fuel utilization, and current density. The impact of advances in underlying SOFC technology on electrical performance was also explored.

solid oxide fuel cell (SOFC), natural gas fuel cel↗

OPERATIONAL TOPOLOGY ESTIMATION OF THREE PHASE UNBALANCED POWER DISTRIBUTION SYSTEMS WITH OUTAGES

Distribution grid, in general, is constructionally loopy but a radially operated network. Opening and closing of suitable tie-switches allows transition from one radial topology to another. Tie-switches ensure reliability and provide restoration paths when faults (outages) occur. The estimation of the system's current operational topology is a precursor to implementing any optimal control actions (during normal operation) or restorative actions (during outage condition). The existing literature in topology detection suffers with several limitations including: (1) computationally intensive nonlinear formulations that are not scalable for large distribution systems, (2) methods requiring exhaustive search for the correct topology by enumerating the complete topological search space, and (3) approaches requiring large volumes of time-series measurements and are not applicable for estimating continuously changing operational topology. Furthermore, the existing literature on distribution grid topology estimation cannot be extended to estimate the operational topology during outage conditions. For operational topology estimation during outages, our objective is to estimate both energized radial feeder and the outaged sections. Starting with a radial topology, these methods identify outaged feeder sections and hence, are inapplicable when the current radial operational topology is not known. In this work, we present a mathematical programming approach to estimate the operational topology of a three-phase unbalanced power distribution system under both outage and normal operating conditions. The aforementioned limitations of existing literature were countered by modeling the problem as a mixed-integer linear programming (MILP) problem which minimizes the errors in available measurements while satisfying the power flow and structural constraints of the system. Specically, a minimum weighted least absolute value estimator is proposed that uses the instantaneous line flow measurements, historical/ forecasted load data, and ping measurements from a limited set of smart meters and solves an MILP to identify the operational topology based on a linearized three-phase unbalanced power flow model. The proposed approach is tested on IEEE 123-bus feeder and 1069 bus multi-feeder test system and the numerical results prove the applicability of the proposed method to large three phase unbalanced grids with high errors in measurements. It is observed that the approach performs well even at high percentages of measurement errors.

GANDLURU NAGA, ANANDINI↗

Optimal Power Flow Pursuit

This paper considers distribution networks featuring inverter-interfaced distributed energy resources, and develops distributed feedback controllers that continuously drive the inverter output powers to solutions of AC optimal power flow (OPF) problems. Particularly, the controllers update the power setpoints based on voltage measurements as well as given (time-varying) OPF targets, and entail elementary operations implementable onto low-cost microcontrollers that accompany power-electronics interfaces of gateways and inverters. The design of the control framework is based on suitable linear approximations of the AC power-flow equations as well as Lagrangian regularization methods. Convergence and OPF-target tracking capabilities of the controllers are analytically established. Overall, the proposed method allows to bypass traditional hierarchical setups where feedback control and optimization operate at distinct time scales, and to enable real-time optimization of distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Volt/VAR Optimization (VVO) Application on GridAPPS-D Platform

There is a large increment in the distributed energy resources (DERs) installation and deployments of smart sensing devices and communication infrastructure; hence, the power distribution network is swiftly evolving from a passive network to an active network. This motivates the development of advanced applications to operate power distribution systems for higher efficiency and reliability. These advanced applications are model-based and data-driven. This requires an advanced distribution management system (ADMS) to provide required data for the optimal operation of the distribution systems by coordinating various grid controllable devices. In this paper a Volt-VAR optimization (VVO) application to coordinate the grid’s legacy and new voltage control devices for conservation voltage reduction (CVR) is deployed on the GridAPPS-D platform (an open-source platform ) for ADMS application development. The VVO application is validated for various operating conditions on using modified IEEE 8500-node distribution test feeders. Further, the application is successfully deployed on the GridAPPS-D platform.

Jha, Rahul↗

Ionomer Optimization for Hydroxide-Exchange-Membrane Water Electrolyzers Operated with Distilled Water: A Modeling Study

The hydroxide-exchange-membrane water electrolyzer (HEMWE) is a promising means to store intermittent renewable energy in the form of hydrogen chemical energy. The hydroxide-exchange ionomer (HEI) in the gas-evolving electrodes and the hydroxide-exchange membrane (HEM) are key components of HEMWE. In this work, we simulate the cell and examine explicitly the impact of HEI and HEM properties with a focus on improving HEMWE performance when operated with distilled water ( i.e ., no supporting electrolyte). The tradeoff between the ionic conductivity gain and electrochemically active surface area (ECSA) loss is studied. For a constant catalyst loading, distributing more catalyst next to the HEM or making thinner but denser catalyst layer is beneficial for HEMWE performance. The results demonstrate that a higher water diffusion coefficient is desired for HEM to supply reactant water to the cathode. In contrast, a lower water diffusion coefficient is preferred for the cathode HEI to retain the water in the regions with high reaction rates. Overall, the findings provide important insights to optimizing HEI/HEM materials for improved HEMWE performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimized Dispatch of Distributed Energy Resources for Resiliency and Power Quality Improvements at the Grid-Edge

Distributed Energy Resources (DERs) installed on low-voltage distribution systems, both utility-owned and nonutility owned may be employed to make improvements to system resiliency and power quality, in addition to simply serving load demand. By selectively dispatching active and reactive power from these existing DERs, improvements in voltage profiles and service availability during adverse events may be achieved. Further benefits can be gained by optimally choosing which DERs to dispatch power from, and the distribution of power from those DERs. For a given operating condition, using Linear Programming methods, optimal power dispatch values for individual DERs can be determined, while considering variables such as voltage gains, losses in the lines and the DERs, and DER reserve capacities. One such optimization technique is developed in this paper, and results from a real-time simulation study on a modified IEEE 13-bus distribution system with three DERs, are being presented. The operation of the optimized DER selection and dispatch algorithm is shown during normal operation of the transmission system when the DERs operate in grid-connected mode. Similar analyses can drive decision making during transmission system failure when the DERs operate in grid-forming or islanded mode.

Chowdhury, Prithwiraj Roy↗

Defining a region of optimization based on engine usage data

Methods and systems for engine control optimization are provided. One or more operating conditions of a vehicle engine are detected. A value for each of a plurality of engine control parameters is determined based on the detected one or more operating conditions of the vehicle engine. A range of the most commonly detected operating conditions of the vehicle engine is identified and a region of optimization is defined based on the range of the most commonly detected operating conditions of the vehicle engine. The engine control optimization routine is initiated when the one or more operating conditions of the vehicle engine are within the defined region of optimization.

33 ADVANCED PROPULSION SYSTEMS↗