Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Pre-launch Estimates for GLAST Sensitivity to Dark Matter Annihilation Signals

We investigate the sensitivity of the Gamma-ray Large Area Space Telescope (GLAST) to indirectly detect weakly interacting massive particles (WIMPs) through the {gamma}-ray signal that their pair annihilation produces. WIMPs are among the favorite candidates to explain the compelling evidence that about 80% of the mass in the Universe is non-baryonic dark matter (DM). They are serendipitously motivated by various extensions of the standard model of particle physics such as Supersymmetry and Universal Extra Dimensions (UED). With its unprecedented sensitivity and its very large energy range (20 MeV to more than 300 GeV) the main instrument on board the GLAST satellite, the Large Area Telescope (LAT), will open a new window of discovery. As our estimates show, the LAT will be able to detect an indirect DM signature for a large class of WIMP models given a cuspy profile for the DM distribution. Using the current state of the art Monte Carlo and event reconstruction software developed within the LAT collaboration, we present preliminary sensitivity studies for several possible sources inside and outside the Galaxy. We also discuss the potential of the LAT to detect UED via the electron/positron channel. Diffuse background modeling and other background issues that will be important in setting limits or seeing a signal are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nanophotonic force microscopy: Characterizing particle–surface interactions using near-field photonics

Direct measurements of particle–surface interactions are important for characterizing the stability and behavior of colloidal and nanoparticle suspensions. Current techniques are limited in their ability to measure pico-Newton scale interaction forces on submicrometer particles due to signal detection limits and thermal noise. In this paper, we present a new technique for making measurements in this regime, which we refer to as nanophotonic force microscopy. Using a photonic crystal resonator, we generate a strongly localized region of exponentially decaying, near-field light that allows us to confine small particles close to a surface. From the statistical distribution of the light intensity scattered by the particle we are able to map out the potential well of the trap and directly quantify the repulsive force between the nanoparticle and the surface. Finally, as shown in this Letter, our technique is not limited by thermal noise, and therefore, we are able to resolve interaction forces smaller than 1 pN on dielectric particles as small as 100 nm in diameter.

36 MATERIALS SCIENCE↗

How well will ton-scale dark matter direct detection experiments constrain minimal supersymmetry?

Weakly interacting massive particles (WIMPs) are amongst the most interesting dark matter (DM) candidates. Many DM candidates naturally arise in theories beyond the standard model (SM) of particle physics, like weak-scale supersymmetry (SUSY). Experiments aim to detect WIMPs by scattering, annihilation or direct production, and thereby determine the underlying theory to which they belong, along with its parameters. Here we examine the prospects for further constraining the Constrained Minimal Supersymmetric Standard Model (CMSSM) with future ton-scale direct detection experiments. We consider ton-scale extrapolations of three current experiments: CDMS, XENON and COUPP, with 1000 kg-years of raw exposure each. We assume energy resolutions, energy ranges and efficiencies similar to the current versions of the experiments, and include backgrounds at target levels. Our analysis is based on full likelihood constructions for the experiments. We also take into account present uncertainties on hadronic matrix elements for neutralino-quark couplings, and on halo model parameters. We generate synthetic data based on four benchmark points and scan over the CMSSM parameter space using nested sampling. We construct both Bayesian posterior PDFs and frequentist profile likelihoods for the model parameters, as well as the mass and various cross-sections of the lightest neutralino. Future ton-scale experiments will help substantially in constraining supersymmetry, especially when results of experiments primarily targeting spin-dependent nuclear scattering are combined with those directed more toward spin-independent interactions.

79 ASTRONOMY AND ASTROPHYSICS↗

Light magnetic dark matter in direct detection searches

We study a fermionic Dark Matter particle carrying magnetic dipole moment and analyze its impact on direct detection experiments. In particular we show that it can accommodate the DAMA, CoGeNT and CRESST experimental results. Assuming conservative bounds, this candidate is shown not to be ruled out by the CDMS, XENON and PICASSO experiments. We offer an analytic understanding of how the long-range interaction modifies the experimental allowed regions, in the cross section versus Dark Matter mass parameter space, with respect to the typically assumed contact interaction. Finally, in the context of a symmetric Dark Matter sector, we determine the associated thermal relic density, and further provide relevant constraints imposed by indirect searches and colliders.

79 ASTRONOMY AND ASTROPHYSICS↗

Full phase space resonant anomaly detection

Physics beyond the Standard Model that is resonant in one or more dimensions has been a longstanding focus of countless searches at colliders and beyond. Recently, many new strategies for have been developed, where sideband information can be used in conjunction with modern machine learning, in order to generate synthetic datasets representing the Standard Model background. Until now, this approach was only able to accommodate a relatively small number of dimensions, limiting the breadth of the search sensitivity. Using recent innovations in point cloud generative models, we show that this strategy can also be applied to the full phase space, using all relevant particles for the anomaly detection. As a proof of principle, we show that the signal from the R&D dataset from the LHC Olympics is findable with this method, opening up the door to future studies that explore the interplay between depth and breadth in the representation of the data for anomaly detection. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Three-body break-up in deuteron-deuteron scattering at 65 MeV/nucleon

In an experiment with a 65 MeV/nucleon polarized deuteron beam on a liquid-deuterium target at Kernfysisch Versneller Instituut, several multibody final states in deuteron-deuteron scattering were identified. For these measurements, a unique and advanced detection system, called the Big Instrument for Nuclear-polarization Analysis, was utilized. We demonstrate the feasibility of measuring vector and tensor polarization observables of the deuteron break-up reaction leading to a three-body final state. The polarization observables were determined with high precision in a nearly background-free experiment. The analysis procedure and some results are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for nuclearites with the ANTARES detector

ANTARES is an underwater detector located in the Mediterranean Sea, near the French city of Toulon, dedicated to the search for cosmic neutrinos. ANTARES is optimized to detect the Cherenkov signal from up-going relativistic particles, but could also observe massive exotic objects, such as magnetic monopoles and nuclearites. In this article we present a search strategy for nuclearites and determine the sensitivity to nuclearites of ANTARES detector in complete configuration, using a set of data taken in 2008.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Portal Vein Embolization with Radiolabeled Polyvinyl Alcohol Particles in a Swine Model: Hepatic Distribution and Implications for Pancreatic Islet Cell Transplantation

The distribution of radiolabeled polyvinyl alcohol microspheres (PVAMs) when infused into the portal vein of domestic swine was investigated, with the purpose of assessing implications for pancreatic islet cell transplantation. PVAMs measuring 100-300 {mu}m (Contour SE) and labeled with {sup 99m}Tc were infused into the main portal vein of 12 swine, with intermittent portal venous pressure measurements. The infusion catheter was introduced antegradely via direct or indirect cannulation of the portal vein. The liver was subsequently divided into anatomical segments. Radioactivity (decay corrected) was measured for {sup 99m}Tc microsphere synthesis, dose preparation, gross organ activities, tissue samples, and blood. Particulate labeling, catheter positioning, and infusion were successful in all cases. The number of particles used was (185,000 {+-} 24,000) with a volume of 1 ml. Mean portal pressure at 5 min was significantly higher than baseline, but without a significant difference at 15 min. Extrahepatic tissue and serum radioactivity was negligible. A significant difference in number of radioactive particles per gram was detected between segments 6/7 and segments 5/8. Intrasegmental activity was analyzed, and for segments 2/3 a significant difference in the percentage dose per gram across samples was demonstrated (P = 0.001). Effective and stable radiolabeling of PVAMs with {sup 99m}Tc-sulfur colloid was demonstrated. Portal venous infusion of 100- to 300-{mu}m particles showed entrapment in the sinusoidal hepatic system with transient portal pressure elevation. Preferential embolization into the right lateral and posterior segments occurs, suggesting that flow dynamics/catheter tip position plays a role in particle distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neutron stars as photon double-lenses: Constraining resonant conversion into ALPs

Axion-photon conversion is a prime mechanism to detect axion-like particles that share a coupling to the photon. We point out that in the vicinity of neutron stars with strong magnetic fields, magnetars, the effective photon mass receives comparable but opposite contributions from free electrons and the radiation field. This leads to an energy-dependent resonance condition for conversion that can be met for arbitrary light axions and leveraged when using systems with detected radio component. Using the magnetar SGR J1745-2900 as an exemplary source, we demonstrate that sensitivity to |g aγ | ~ 10 -12 GeV -1 or better can be gained for m a ≲ 10 -6 eV, with the potential to improve current constraints on the axion-photon coupling by more than one order of magnitude over a broad mass range. With growing insights into the physical conditions of magnetospheres of magnetars, the method hosts the potential to become a serious competitor to future experiments such as ALPS-II and IAXO in the search for axion-like particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Median recoil direction as a WIMP directional detection signal

Direct detection experiments have reached the sensitivity to detect dark matter weakly interacting massive particles (WIMPs). Demonstrating that a putative signal is due to WIMPs, and not backgrounds, is a major challenge, however. The direction dependence of the WIMP scattering rate provides a potential WIMP 'smoking gun'. If the WIMP distribution is predominantly smooth, the Galactic recoil distribution is peaked in the direction opposite to the direction of Solar motion. Previous studies have found that, for an ideal detector, of order 10 WIMP events would be sufficient to reject isotropy, and rule out an isotropic background. We examine how the median recoil direction could be used to confirm the WIMP origin of an anisotropic recoil signal. Specifically, we determine the number of events required to confirm the direction of solar motion as the median inverse recoil direction at 95% confidence. We find that for zero background 31 events are required, a factor of {approx}2 more than are required to simply reject isotropy. We also investigate the effect of a nonzero isotropic background. As the background rate is increased the number of events required increases, initially fairly gradually and then more rapidly, once the signal becomes subdominant. We also discuss the effect of features in the speed distribution at large speeds, as found in recent high resolution simulations, on the median recoil direction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Particles in the lower troposphere over the High Plains of the United States. I - Size distributions, elemental compositions and morphologies

Airborne measurements of particle size distributions obtained during the spring and summer of 1975-1976 at various locations in the high plains of the U.S. are presented. The instrumentation and techniques used to collect the data are described. Particle number, surface area, and volume distribution are measured; differences in particle concentrations are investigated. Variables in particle size are related to changes in strength of ground sources of Aitken nuclei, age of the particle population, and presence or absence of rain. An accumulation mode between particles diameters of 0.1-1 micron, a coarse particle mode between particle diameters between 10-20 microns, and a nucleation mode at particle diameters less than 0.1 micron are detected. The control of the accommodation and coarse particle modes and their influence on particle concentration are studied. The elemental composition of the particles is analyzed and the morphologies are examined with an electron scanner microscope.

Hobbs, P. V.↗

The ICE project

The International Cometary Explorer (ICE) spacecraft passed through the plasma tail of Comet Giacobini-Zinner (G/Z) on Sept. 11, 1985, and made in situ measurements of particles, fields, and waves. The scientific results indicate that Alfven's magnetic-field capture and draping model is correct; that the comet/solar-wind interaction produces energetic ions (probably by the pick-up process), and that the bow wave, as seen on the flanks, is not a shock but an extended interaction region. It is concluded that the ICE spacecraft survived the encounter virtually unscathed and made field and particle measurements upstream of Comet Halley, actually detecting the comet via plasma wave and energetic particle measurements.

Brandt, J. C.↗

Ultra-sensitive magnetic microscopy with an optically pumped magnetometer

Optically pumped magnetometers (OPMs) based on lasers and alkali-metal vapor cells are currently the most sensitive non-cryogenic magnetic field sensors. Many applications in neuroscience and other fields require high-resolution, high-sensitivity magnetic microscopic measurements. In order to meet this demand we combined a cm-size spin-exchange relaxation-free (SERF) OPM and flux guides (FGs) to realize an ultra-sensitive FG-OPM magnetic microscope. The FGs serve to transmit the target magnetic flux to the OPM thus improving both the resolution and sensitivity to small magnetic objects. We investigated the performance of the FG-OPM device using experimental and numerical methods, and demonstrated that an optimized device can achieve a unique combination of high resolution (80 μm) and high sensitivity (8.1 pT/). Additionally, we also performed numerical calculations of the magnetic field distribution in the FGs to estimate the magnetic noise originating from the domain fluctuations in the material of the FGs. We anticipate many applications of the FG-OPM device such as the detection of micro-biological magnetic fields; the detection of magnetic nano-particles; and non-destructive testing. From our theoretical estimate, an FG-OPM could detect the magnetic field of a single neuron, which would be an important milestone in neuroscience.

47 OTHER INSTRUMENTATION↗

Discovering hidden sectors with monophoton Z{sup '} searches

In many theories of physics beyond the standard model, from extra dimensions to Hidden Valleys and models of dark matter, Z{sup '} bosons mediate between standard model particles and hidden sector states. We study the feasibility of observing such hidden states through an invisibly decaying Z{sup '} at the LHC. We focus on the process pp{yields}{gamma}Z{sup '}{yields}{gamma}XX{sup {dagger}}, where X is any neutral, (quasi-) stable particle, whether a standard model neutrino or a new state. This complements a previous study using pp{yields}ZZ{sup '}{yields}l{sup +}l{sup -}XX{sup {dagger}}. Only the Z{sup '} mass and two effective charges are needed to describe this process. If the Z{sup '} decays invisibly only to standard model neutrinos, then these charges are predicted by observation of the Z{sup '} through the Drell-Yan process, allowing discrimination between Z{sup '} decays to standard model {nu}'s and invisible decays to new states. We carefully discuss all backgrounds and systematic errors that affect this search. We find that hidden sector decays of a 1 TeV Z{sup '} can be observed at 5{sigma} significance with 50 fb{sup -1} at the LHC. Observation of a 1.5 TeV state requires super-LHC statistics of 1 ab{sup -1}. Control of the systematic errors, in particular, the parton distribution function uncertainty of the dominant Z{gamma} background, is crucial to maximize the LHC search reach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Second-Class Currents in tau{sup -}->omegapi{sup -}nu{sub t}au

We report an analysis of tau{sup -} decaying into omegapi{sup -}nu{sub t}au with omega->pi{sup +}pi{sup -}pi{sup 0} using a data sample containing nearly 320x10{sup 6}tau pairs collected with the BABAR detector at the PEP-II B-Factory. We find no evidence for second-class currents, and we set an upper limit of 0.69% at 90% confidence level for the fraction of second-class currents in this decay mode.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

VUV light collection enhancement with metasurface lenses

Vacuum-ultraviolet (VUV) light has applications in many areas of fundamental research and technology, including high-energy physics (HEP) experiments and especially those based on scintillation of noble elements (xenon and argon).There are persistent challenges associated with the detection of the VUV photons in particle detectors, e.g. strong absorption by structural materials and low detection efficiency of the photosensors.Metasurfaces are relatively novel nano-fabricated devices which offer unprecedented control of light with a wide field of view and diffraction-limited focusing.This contribution will present the first linear metasurface lens operating in the VUV spectral range with the measured diffraction efficiencies above 50%.The design and fabrication processes will be described in detail, as well as the characterization measurements, and possible applications in the HEP experiments will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Description of the plasma diagnostics package (PDP) for the OSS-1 Shuttle mission and JSC plasma chamber test in conjunction with the fast pulse electron gun (FPEG)

The objectives, equipment, and techniques for the plasma diagnostics package (PDP) carried by the OSS-1 instrument payload of the STS-4 and scheduled for the Spacelab-2 mission are described. The goals of the first flight were to examine the Orbiter-magnetoplasma interactions by measuring the electric and magnetic field strengths, the ionized particle wakes, and the generated waves. The RMS was employed to lift the unit out of the bay in order to allow characterization of the fields, EM interference, and plasma contamination within 15 m of the Orbiter. The PDP will also be used to examine plasma depletion, chemical reaction rates, waves, and energized plasma produced by firing of the Orbiter thrusters. Operation of the PDP was carried out in the NASA Space Environment Simulation Laboratory test chamber, where the PDP was used to assay the fields, fluxes, wave amplitudes, and particle energy spectra. The PDP instrumentation is also capable of detecting thermal ions, thermal electrons suprathermal particles, VHF/UHF EMI levels, and the S-band field strength.

Shawhan, S. D.↗

Kinetic Inductance Detectors for Dark Matter Searches

Decades of astrophysical observations suggest that 23% of the mass energy of the universe is dark. Meanwhile, particle physics theories favor the existence of a stable and weakly interacting particle, which has yet to be detected. These realities combine to formulate a very well motivated particle dark matter candidate, which was produced in the early universe and still lingers in abundance today. The expectation of a small weak interaction cross-section enables the instrumentation of experiments designed to discover the nature of the dark matter which continues to be an overarching question of cosmology. A detector for this dark matter candidate senses energy from occasional collisions between the dark matter and atomic nuclei; the more nuclei in the detector, the greater its sensitivity to dark matter. The detectors of the Cryogenic Dark Matter Search (CDMS) measure phonons and charge emanating from recoiling germanium nuclei. Its phonon sensors, though exquisitely sensitive, are relatively complicated to fabricate and deploy. Responding to the scientific imperative to increase dark matter sensitivity, we look for a simpler phonon sensor technology. Kinetic inductance based phonon sensors (KIPS) are superconducting thin film microwave frequency resonant circuits. Phonon energy impinging on the film alters its surface impedance, which alters the characteristics of the resonance. KIPS can be made with relatively large, millimeter sized features which makes them easier to fabricate and reduces variations between detectors. This instrumentation focused thesis shows that KIPS can be used as a simple and sensitive phonon sensor for the CDMS detector. KIPS design aspects, competitiveness to the current transition edge phonon sensors, readout considerations and suggestions on how to instrument them in future dark matter experiments will be presented. The broader applicability of KIPS in nuclear non-proliferation and other physics investigations is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗