Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Particle production during inflation: Observational constraints and signatures

In a variety of inflation models the motion of the inflaton may trigger the production of some noninflaton particles during inflation, for example, via parametric resonance or a phase transition. Particle production during inflation leads to observables in the cosmological fluctuations, such as features in the primordial power spectrum and also non-Gaussianities. Here we focus on a prototype scenario with inflaton, {phi}, and isoinflaton, {chi}, fields interacting during inflation via the coupling g{sup 2}({phi}-{phi}{sub 0}){sup 2}{chi}{sup 2}. Since several previous investigations have hinted at the presence of localized 'glitches' in the observed primordial power spectrum, which are inconsistent with the simplest power-law model, it is interesting to determine the extent to which such anomalies can be explained by this simple and microscopically well-motivated inflation model. Our prototype scenario predicts a bumplike feature in the primordial power spectrum, rather than an oscillatory 'ringing' pattern as has previously been assumed. We discuss the observational constraints on such features using a variety of cosmological data sets. We find that bumps with amplitudes as large as O(10%) of the usual scale-invariant fluctuations from inflation, corresponding to g{sup 2}{approx}0.01, are allowed on scales relevant for cosmic microwave background experiments. Our results imply an upper limit on the coupling g{sup 2} (for a given {phi}{sub 0}) which is crucial for assessing the detectability of the non-Gaussianity produced by inflationary particle production. We also discuss more complicated features that result from superposing multiple instances of particle production. Finally, we point to a number of microscopic realizations of this scenario in string theory and supersymmetry and discuss the implications of our constraints for the popular brane/axion monodromy inflation models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Validation of FAST.Farm Against Large-Eddy Simulations

FAST.Farm is a new midfidelity, multiphysics engineering tool for modeling the power performance and structural loads of wind turbines within a wind farm, including wake and array effects. Previous calibration of the tuneable model parameters of FAST.Farm has shown that its prediction of wake dynamics for a single wind turbine across different atmospheric stability conditions and nacelle-yaw errors matches well with high-fidelity large-eddy simulation at a small fraction of the computational expense. This paper presents a validation of FAST.Farm against large-eddy simulation for a series of cases - independent from those used to support the calibration - considering single-turbine and small wind-farm scenarios, which are both subject to variations in inflow and control. The validation has demonstrated that FAST.Farm reasonably accurately predicts: (1) thrust and power for individual turbines both in isolation and down the row of the small wind farm, (2) wake meandering behavior across different atmospheric conditions, and (3) averaged wake-deficit advection, evolution, and merging effects. As a result, the validation also highlights potential physics that could be improved in FAST.Farm in the future.

17 WIND ENERGY↗

Effect of Pore Size, Morphology and Orientation on the Bulk Stiffness of a Porous Ti35Nb4Sn Alloy

The metal foams of a titanium alloy were designed to study porosity as well as pore size and shape independently. These were manufactured using a powder metallurgy/space-holder technique that allowed a fine control of the pore size and morphology; and then characterized and tested against well-established models to predict a relationship between porosity, pore size and shape, and bulk stiffness. Among the typically used correlations, existing power-law models were found to be the best fit for the prediction of macropore morphology against compressive elastic moduli, outperforming other models such as exponential, polynomial or binomial. Other traditional models such as linear ones required of updated coefficients to become relevant to metal porous sintered macrostructures. The new coefficients reported in this study contribute toward a design tool that allows the tailoring of mechanical properties through porosity macrostructure. The results show that, for the same porosity range, pore shape and orientation have a significant effect on mechanical performance and that they can be predicted. Conversely, pore size has only a mild impact on bulk stiffness.

36 MATERIALS SCIENCE↗

Integrated State Estimation and Contingency Analysis Software Implementation using High Performance Computing Techniques

Power system simulation tools are traditionally developed in sequential mode and codes are optimized for single core computing only. However, the increasing complexity in the power grid models requires more intensive computation. The traditional simulation tools will soon not be able to meet the grid operation requirements. Therefore, power system simulation tools need to evolve accordingly to provide faster and better results for grid operations. This paper presents an integrated state estimation and contingency analysis software implementation using high performance computing techniques. The software is able to solve large size state estimation problems within one second and achieve a near-linear speedup of 9,800 with 10,000 cores for contingency analysis application. The performance evaluation is presented to show its effectiveness.

Chen, Yousu↗

ANALYTICAL AND MONTE CARLO RESULTS FOR THE SURFACE-BRIGHTNESS-DIAMETER RELATIONSHIP IN SUPERNOVA REMNANTS

The surface-brightness-diameter relationship for supernova remnants is explained by adopting a model of direct conversion of the flux of kinetic energy into synchrotron luminosity. Two laws of motion are adopted: a power-law model for the radius-time relationship and a model that uses the thin layer approximation. The fluctuations in the log-log surface diameter relationship are modeled by a Monte Carlo simulation. In this model, a new probability density function for the density as a function of the galactic height is introduced.

79 ASTRONOMY AND ASTROPHYSICS↗

THE INTEGRAL SOURCE IGR J16328-4726: A HIGH-MASS X-RAY BINARY FROM THE BEPPOSAX ERA

We report on temporal and spectral analysis of the INTEGRAL fast transient candidate IGR J16328-4726 observed with BeppoSAX in 1998 and more recently with INTEGRAL. The MECS X-ray data show a frequent microactivity typical of the intermediate state of supergiant fast X-ray transients and a weak flare with a duration of {approx}4.6 ks. The X-ray emission in the 1.5-10 keV energy range is well described through the different time intervals by an absorbed power-law model. Comparing spectra from the lower emission level up to the peak of the flare, we note that while the power-law photon index was constant ({approx}2), the absorption column density varied by a factor of up to {approx}6-7, reaching a value of {approx}2 Multiplication-Sign 10{sup 23} cm{sup -2} at the peak of the flare. Analysis of the long-term INTEGRAL/IBIS light curve confirms and refines the proposed {approx}10.07 day period, and the derived ephemeris places the BeppoSAX observations away from periastron. Using the near- and the mid-IR available observations, we constructed a spectral infrared distribution for the counterpart of IGR J16328-4726, allowing us to identify its counterpart as a high-mass OB type star and to classify this source as a firm HMXB. Following the standard clumpy wind theory, we estimated the mass and the radius of the clump responsible for the flare. The obtained values of M {sub cl} {approx_equal} 4 Multiplication-Sign 10{sup 22}g and R{sub cl} {approx_equal} 4.4 Multiplication-Sign 10{sup 6} km are in agreement with expected values from theoretical predictions.

79 ASTRONOMY AND ASTROPHYSICS↗

Feeder Power Disaggregation: A Data-Efficient Matrix Completion Approach

This paper presents a data-driven algorithm for the feeder power disaggregation problem in distribution systems. Leveraging spatio-temporal power patterns in residential homes, residential power is discomposed into three components: sparse-switching loads, periodic loads, and photovoltaic (PV) generation, which are characterized through the design of two sparse matrices and a low-rank matrix. The matrix completion process is data-efficient because of the matrix sparsity and low rankness, along with the use of power system models. The proposed approach is tested using real-world residential data set on a 33-bus distribution system, demonstrating accurate power disaggregation with efficient matrix completion.

distribution system↗

Warm inflation in f(G) theory of gravity

The aim of this paper is to explore warm inflation in the background of f(G) theory of gravity using scalar fields for the FRW universe model. We construct the field equations under slow-roll approximations and evaluate the slow-roll parameters, scalar and tensor power spectra and their corresponding spectral indices using viable power-law model. These parameters are evaluated for a constant as well as variable dissipation factor during intermediate and logamediate inflationary epochs. We also find the number of e-folds and tensor- scalar ratio for each case. The graphical behavior of these parameters proves that the isotropic model in f(G) gravity is compatible with observational Planck data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CIMantic Graphs

CIMantic Graphs (aka CIM-Graph) is a new python library developed by PNNL to reduce the burden of working with the Common Information Model. CIMantic Graphs takes a novel approach of building in-memory labeled property graphs for creating, parsing, and editing CIM power system models.

Anderson, Alexander↗

Duke Energy Carbon-Free Resource Integration Study

Duke Energy has partnered with the National Renewable Energy Laboratory (NREL) to evaluate pathways to achieving their carbon-free targets and to assess the operational impacts of the resulting system. This report details findings from Phase II of the Duke Low Carbon Resource Integration study, which consisted of three separate but interrelated analyses: (1) a resource assessment exploring the technical and economic potential and characteristics of wind and solar resources in the Carolinas; (2) capacity expansion modeling identifying the least-cost investment pathways for achieving 70% CO 2 emissions reductions in North Carolina by 2030 and a net-zero electricity system by 2050; and (3) detailed production cost modeling of power system operations at the higher shares of low- and zero-carbon emitting generation sources, informed by the capacity expansion modeling portion of the analysis. The analysis finds that Duke Energy can approach the 2030 and 2050 emissions target in North Carolina through investment in a combination of solar, wind, and storage along with maintaining its existing nuclear fleet. The average cost of CO 2 abatement in the Carolinas through 2021-2050 is on the order of $\$27-33$ per metric ton (range of $\$9-34$ per metric ton across key sensitivities).Duke Energy can expected increased interchange with neighbors to help balance higher levels of solar, although the ability to do this will depend on whether neighboring regions also move to integrate more carbon-free resources. As Duke Energy moves toward both the 2030 and 2050 targets, addressing energy needs during the winter peak period becomes particularly important, and the system relies on the availability of resources such as renewable or hydrogen combustion turbines, seasonal storage, or other similar technologies that are dispatchable but able to operate at low capacity factors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Microwave transmission system for space power

The system considered makes use of a combined dipole antenna and rectifier. The dipole elements feed a balanced transmission line low-pass filter. A description of a laboratory model microwave power transmission system is given and a higher-power project with a longer range is discussed. Space power transmission experiments are also considered. It is pointed out that the investigations have shown that high overall transmission link efficiencies are possible.

Dickinson, R. M.↗

A comparison of GaAs and Si hybrid solar power systems

Five different hybrid solar power systems using silicon solar cells to produce thermal and electric power are modeled and compared with a hybrid system using a GaAs cell. Among the indices determined are capital cost per unit electric power plus mechanical power, annual cost per unit electric energy, and annual cost per unit electric plus mechanical work. Current costs are taken to be $35,000/sq m for GaAs cells with an efficiency of 15% and $1000/sq m for Si cells with an efficiency of 10%. It is shown that hybrid systems can be competitive with existing methods of practical energy conversion. Limiting values for annual costs of Si and GaAs cells are calculated to be 10.3 cents/kWh and 6.8 cents/kWh, respectively. Results for both systems indicate that for a given flow rate there is an optimal operating condition for minimum cost photovoltaic output. For Si cell costs of $50/sq m optimal performance can be achieved at concentrations of about 10; for GaAs cells costing 1000/sq m, optimal performance can be obtained at concentrations of around 100. High concentration hybrid systems offer a distinct cost advantage over flat systems.

Heinbockel, J. H.↗

Solar Power System Options for the Radiation and Technology Demonstration Spacecraft

The Radiation and Technology Demonstration (RTD) Mission has the primary objective of demonstrating high-power (10 kilowatts) electric thruster technologies in Earth orbit. This paper discusses the conceptual design of the RTD spacecraft photovoltaic (PV) power system and mission performance analyses. These power system studies assessed multiple options for PV arrays, battery technologies and bus voltage levels. To quantify performance attributes of these power system options, a dedicated Fortran code was developed to predict power system performance and estimate system mass. The low-thrust mission trajectory was analyzed and important Earth orbital environments were modeled. Baseline power system design options are recommended on the basis of performance, mass and risk/complexity. Important findings from parametric studies are discussed and the resulting impacts to the spacecraft design and cost.

Kerslake, Thomas W.↗

Picking the Best from the All-Resources Menu: Advanced Tools for Resource Planning

Introduces the wide range of electric power systems modeling types and associated questions they can help answer. The presentation focusses on modeling needs for high levels of Distributed Energy Resources (DERs), renewables, and inverter-based technologies as alternatives to traditional centralized power systems. Covers Dynamics, Production Cost/QSTS, Metric Assessment, Resource Planning, and Integrated Simulations with examples drawn from NREL's past and on-going projects. Presented at the McKnight Foundation workshop on 'An All-Resources Approach to Planning for a More Dynamic, Low-Carbon Grid' exploring grid modernization options to replace retiring coal plants in Minnesota.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Probing the gamma-ray emission from HESS J1834–087 using H.E.S.S. and Fermi LAT observations

Aims. Previous observations with the High Energy Stereoscopic System (H.E.S.S.) have revealed an extended very-high-energy (VHE; E> 100 GeV) γ-ray source, HESS J1834-087, coincident with the supernova remnant (SNR) W41. The origin of the γ-ray emission was investigated in more detail with the H.E.S.S. array and the Large Area Telescope (LAT) onboard the Fermi Gamma-ray Space Telescope. Methods. For this research, the γ-ray data provided by 61 h of observations with H.E.S.S., and four years with the Fermi LAT were analyzed, covering over five decades in energy from 1.8 GeV up to 30 TeV. The morphology and spectrum of the TeV and GeV sources were studied and multiwavelength data were used to investigate the origin of the γ-ray emission toward W41. Results. The TeV source can be modeled with a sum of two components: one point-like and one significantly extended (σ TeV = 0.17° ± 0.01°), both centered on SNR W41 and exhibiting spectra described by a power law with index Γ TeV ≃ 2.6. The GeV source detected with Fermi LAT is extended (σ GeV = 0.15° ± 0.03°) and morphologically matches the VHE emission. Its spectrum can be described by a power-law model with an index Γ GeV = 2.15 ± 0.12 and smoothly joins the spectrum of the whole TeV source. A break appears in the γ-ray spectra around 100 GeV. No pulsations were found in the GeV range. Conclusions. Two main scenarios are proposed to explain the observed emission: a pulsar wind nebula (PWN) or the interaction of SNR W41 with an associated molecular cloud. X-ray observations suggest the presence of a point-like source (a pulsar candidate) near the center of the remnant and nonthermal X-ray diffuse emission that could arise from the possibly associated PWN. The PWN scenario is supported by the compatible positions of the TeV and GeV sources with the putative pulsar. However, the spectral energy distribution from radio to γ-rays is reproduced by a one-zone leptonic model only if an excess of low-energy electrons is injected following a Maxwellian distribution by a pulsar with a high spin-down power (>1037 erg s-1). This additional low-energy component is not needed if we consider that the point-like TeV source is unrelated to the extended GeV and TeV sources. Finally, the interacting SNR scenario is supported by the spatial coincidence between the γ-ray sources, the detection of OH (1720 MHz) maser lines, and the hadronic modeling.

79 ASTRONOMY AND ASTROPHYSICS↗

ADMS State of the Industry and Gap Analysis

An Advanced distribution management system (ADMS) is a platform for optimized distribution system operational management. This platform comprises of distribution management system (DMS) applications, supervisory control and data acquisition (SCADA), outage management system (OMS), and distributed energy resource management system (DERMS). One of the primary objectives of this work is to study and analyze several ADMS component and auxiliary systems. All the important component and auxiliary systems, SCADA, GISs, DMSs, AMRs/AMIs, OMSs, and DERMS, are discussed in this report. Their current generation technologies are analyzed, and their integration (or evolution) with an ADMS technology is discussed. An ADMS technology state of the art and gap analysis is also presented. There are two technical gaps observed. The integration challenge between the component operational systems is the single largest challenge for ADMS design and deployment. Another significant challenge noted is concerning essential ADMS applications, for instance, fault location, isolation, and service restoration (FLISR), volt-var optimization (VVO), etc. There are a relatively small number of ADMS application developers as ADMS software platform is not open source. There is another critical gap and while not being technical in nature (when compared the two above) is still important to consider. The data models currently residing in utility GIS systems are either incomplete or inaccurate or both. This data is essential for planning and operations because it is typically one of the primary sources from which power system model are created. To achieve the full potential of ADMS, the ability to execute acute Power Flow solution is an important pre-requisite. These critical gaps are hindering wider Utility adoption of an ADMS technology. The development of an open architecture platform can eliminate many of these barriers and also aid seamless integration of distribution Utility legacy systems with an ADMS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Physics-informed heterogeneous graph neural networks for DC blocker placement

The threat of geomagnetic disturbances (GMDs) to the reliable operation of the bulk energy system has spurred the development of effective strategies for mitigating their impacts. One such approach involves placing transformer neutral blocking devices, which interrupt the path of geomagnetically induced currents (GICs) to limit their impact. The high cost of these devices and the sparsity of transformers that experience high GICs during GMD events, however, calls for a sparse placement strategy that involves high computational cost. To address this challenge, we developed a physics-informed heterogeneous graph neural network (PIHGNN) for solving the graph-based dc-blocker placement problem. Our approach combines a heterogeneous graph neural network (HGNN) with a physics-informed neural network (PINN) to capture the diverse types of nodes and edges in ac/dc networks and incorporates the physical laws of the power grid. We train the PIHGNN model using a surrogate power flow model and validate it using case studies. Results demonstrate that PIHGNN can effectively and efficiently support the deployment of GIC dc-current blockers, ensuring the continued supply of electricity to meet societal demands. Furthermore, our approach has the potential to contribute to the development of more reliable and resilient power grids capable of withstanding the growing threat that GMDs pose.

24 POWER TRANSMISSION AND DISTRIBUTION↗