Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Data recording and processing for speckle image reconstruction

Image reconstruction from astronomical speckle data using the Knox-Thompson algorithm has now been extensively demonstrated as feasible through analysis and computer simulations. Experimental verification of the technique and its implementation for astronomy places stringent constraints on the recording system and requires complex processing algorithms to handle the many experimental details. In this paper we describe a video recording system specifically designed for the requirements of speckle imaging. This system has been built and tested, yielding high quality image reconstructions from a laboratory-atmospheric simulator for a wide range of input light levels and test objects.

Nisenson, P.↗

SU-E-I-11: A New Cone-Beam CT System for Bedside Head Imaging

Purpose: To design and develop a new mobile cone-beam CT (CBCT) system for head imaging with good soft-tissue visibility, to be used bedside in ICU and neurosurgery department to monitor treatment and operation outcome in brain patients. Methods: The imaging chain consists of a 30cmx25cm amorphous silicon flat panel detector and a pulsed, stationary anode monoblock x-ray source of 100kVp at a maximal tube current of 10mA. The detector and source are supported on motorized mechanisms to provide detector lateral shift and source angular tilt, enabling a centered digital radiographic imaging mode and half-fan CBCT, while maximizing the use of the x-ray field and keep the source to detector distance short. A focused linear anti-scatter grid is mounted on the detector, and commercial software with scatter and other corrective algorithms is used for data processing and image reconstruction. The gantry rotates around a horizontal axis, and is able to adjust its height for different patient table positions. Cables are routed through a custom protective sleeve over a large bore with an in-plane twister band, facilitating single 360-degree rotation without a slip-ring at a speed up to 5 seconds per rotation. A UPS provides about 10 minutes of operation off the battery when unplugged. The gantry is on locked casters, whose brake is control by two push handles on both sides for easy reposition. The entire system is designed to have a light weight and a compact size for excellent maneuverability. Results: System design is complete and main imaging components are tested. Initial results will be presented and discussed later in the presentation. Conclusion: A new mobile CBCT system for head imaging is being developed. With its compact size, a large bore, and quality design, it is expected to be a useful imaging tool for bedside uses. The work is supported by a grant from Chinese Academy of Sciences.

60 APPLIED LIFE SCIENCES↗

Beyond Taylor’s hypothesis: a novel volumetric reconstruction of velocity and density fields for variable‑density and shear flows

Abstract This work presents a novel numerical procedure for reconstructing volumetric density and velocity fields from planar laser-induced fluorescence (PLIF) and stereoscopic particle image velocimetry (SPIV) data. This new method is theoretically and practically demonstrated to provide more accurate 3D vortical structures and density fields in high shear flows than reconstruction methods based on the mean convective velocity. While Taylor’s hypothesis of frozen turbulence is commonly applied by using the local mean streamwise velocity, the proposed algorithm uses the measured local instantaneous velocity for data convection. It consists of a step-by-step reconstruction based on a mixed Lagrangian–Eulerian solver that includes the 3D interpolation of scattered flow data and that relaxes the Taylor’s hypothesis by iterative enforcement of the incompressibility constraint on the velocity field. This methodology provides 3D fields with temporal resolution, spatial resolution, and accuracy comparable to that of real 3D snapshots, thus providing a practical alternative to tomographic measurements. The procedure is validated using numerical data of the constant-density channel flow available on the Johns Hopkins University Turbulence Database (JHTDB), showing the accurate reconstruction of the 3D velocity field. The algorithm is applied to an experimental dataset of PLIF and SPIV measurements of a variable-density jet flow, demonstrating its capability to provide 3D velocity and density fields that are more consistent with the Navier–Stokes equations compared to the mean flow convective method. Graphic abstract

42 ENGINEERING↗

Artificial Intelligence for Event Reconstruction and Higgs Physics at CMS and Future Colliders

This dissertation charts a trajectory in which advances in artificial intelligence (AI) play a central role in pushing the high-energy physics frontier, complementing progress driven by higher collision energies and larger colliders. The discovery potential of the LHC and future colliders relies on accurate reconstruction of increasingly complex particle collision events. In the CMS experiment, this task is performed by the particle-flow (PF) algorithm. This dissertation presents the first implementation of a machine-learning-based particle-flow (MLPF) reconstruction in the CMS detector based on transformer architectures. In simulated top quark--antiquark pair (ttbar) events under LHC Run~3 (2023--2024) conditions, MLPF improves jet energy resolution by 10--20\% compared to standard PF for jets with transverse momentum between 30--100\GeV. Runtime performance is evaluated using simulated multijet events, with a median inference time of 20\unit{ms} per event on an NVIDIA L4 GPU, compa red to approximately 110\unit{ms} for standard PF. The MLPF algorithm is also validated on Run~3 collision data, representing the first data-validated ML-based reconstruction pipeline at any LHC experiment. We then extend MLPF toward future electron--positron colliders and introduce the first full-simulation cross-detector transfer learning workflow for PF reconstruction. The model is pre-trained on simulated events from the Compact Linear Collider detector (CLICdet) and fine-tuned on the CLIC-like detector (CLD) proposed for the Future Circular Collider (FCC). This approach achieves up to a 40\% improvement in jet energy resolution over rule-based reconstruction while reducing the required training dataset size by an order of magnitude, demonstrating the potential of AI to accelerate detector development and optimization. This dissertation also demonstrates how modern AI techniques enhance the sensitivity of LHC physics analyses. A CMS search for highly Lorentz-boosted Higgs bosons decaying to \textrm{W} boson pairs is presented, focusing on the single-lepton final state. A dedicated fine-tuning strategy for \ParT yields an approximately 70\% increase in expected sensitivity relative to the baseline model. The analysis uses proton--proton collision data at a center-of-mass energy of \ensuremath{\sqrt{s}=13\TeV} collected by CMS between 2016 and 2018, corresponding to an integrated luminosity of 138\ensuremath{\ \mathrm{fb}^{-1}}. The expected significance of the search is $1.86\sigma$, with an observed signal strength of $-0.19^{+0.48}_{-0.46}$. Finally, explainable AI techniques are applied to the MLPF and \ParticleNet algorithms using layerwise relevance propagation, showing that both models base their predictions on physically meaningful features consistent with our physics intuition. Together, these results demonstrate how advanced AI methods can enhance reconstruction, analysis sensitivity, and interpretability, shaping the next era of experimental parti cle physics.

Mokhtar, Farouk [UC, San Diego]↗

NOvA Reconstruction using Deep Learning [Slides]

The NOvA experiment has made measurements of the disappearance of νμ and the appearance of νe in the NuMI beam at Fermilab. Key to these measurements is the identification of the neutrino flavor and measurement of the neutrino energy, for which NOvA has implemented deep learning algorithms utilizing tools from the field of computer vision. These algorithms, first applied to NOvA's 2016 results, showed significant improvement over previous reconstruction methods. I will present NOvA's implementation of deep learning algorithms using convolutional neural networks for identification of event neutrino flavor and single particles used in the 2018 analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstruction of cosmic-ray muon events with CUORE

We report the in-situ 3D reconstruction of through-going muons in the CUORE experiment, a cryogenic calorimeter array searching for neutrinoless double beta (0vββ) decay, leveraging the segmentation of the detector. Due to the slow time response of the detector, time-of-flight estimation is not feasible. Therefore, the track reconstruction is performed using a multi-objective optimization algorithm that relies on geometrical information from the detector as a whole. We measure the integral flux of cosmic-ray muons underground at the Laboratori Nazionali del Gran Sasso, and find our value to be in good agreement with other experiments that have performed a similar measurement. To our knowledge, this work represents the first demonstration of 3D particle tracking and reconstruction of through-going muons with per-event angular determination in a millikelvin cryogenic detector array. The analysis performed for this work will be critical for validating the muon-related background in CUPID, a next-generation 0vββ experiment, and for follow-up studies on detector response and on delayed products induced by cosmic-ray muons.

Adams, D. Q. [University of South Carolina]↗

Filament capturing with the Multimaterial Moment-of-Fluid method

A novel method for capturing two-dimensional, thin, under-resolved material configurations, known as “filaments,” is presented in the context of interface reconstruction. This technique uses a partitioning procedure to detect disconnected regions of material in the advective preimage of a cell (indicative of a filament) and makes use of the existing functionality of the Multimaterial Moment-of-Fluid interface reconstruction method to accurately capture the under-resolved feature, while exactly conserving volume. An algorithm for Adaptive Mesh Refinement in the presence of filaments is developed so that refinement is introduced only near the tips of filaments and where the Moment-of-Fluid reconstruction error is still large. Comparison to the standard Moment-of-Fluid method is made. It is demonstrated that using filament capturing at a given resolution yields gains in accuracy comparable to introducing an additional level of mesh refinement at significantly lower cost.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-dimensional reconstruction and morphologic characteristics of porous metal fiber sintered sheet

This paper presents an approach to achieve morphological characterizing for complex porous materials based on micro X-ray tomography images, with an example of a novel porous metal fiber sheet produced through solid-state sintering method. The geometrical reconstruction was performed after selection of volume of interest and image processing of anisotropic diffusion smooth. The reconstructed gray level images were then transferred into binary images by adjusting binarization threshold according to the actual porosity. Taking into account the tubular structural feature of the fibers, skeleton extraction algorithm based on the distance transform function was applied and further improved by the scale axis transform method. The skeleton was later pruned and segmented according to the contact points to perform morphological characterizing. Compared with actual manufacturing parameters, the style, length, radius, orientation and tortuosity of fiber segments were discussed. The results show that our proposed method can well describe the actual geometrical and morphological characteristics, which will provide a promising method for the structural description of fibrous networks. - Highlights: • Micro-CT technology was used to achieve the 3D geometrical reconstruction. • Skeleton extraction algorithm was modified to get the medial skeleton. • Skeleton filter operation was adopted to deal with the segmented skeleton. • Useful morphological statistics was obtained through skeleton segments. • Relationship between structure and manufacturing processes was discussed.

36 MATERIALS SCIENCE↗

SU-D-BRF-07: Ultrasound and Fluoroscopy Based Intraoperative Image-Guidance System for Dynamic Dosimetry in Prostate Brachytherapy

Purpose: Prostate brachytherapy is a common treatment method for low-risk prostate cancer patients. Intraoperative treatment planning is known to improve the treatment procedure and the outcome. The current limitation of intraoperative treatment planning is the inability to localize the seeds in relation to the prostate. We developed an image-guidance system to fulfill this need to achieve intraoperative dynamic dosimetry in prostate brachytherapy. Methods: Our system is based on standard imaging equipments available in the operating room, including the transrectal ultrasound (TRUS) and the mobile C-arm. A simple fiducial is added to compute the C-arm pose. Three fluoroscopic images and an ultrasound volume of the seeds and the prostate are acquired and processed by four image processing algorithms: seed segmentation, fiducial detection with pose estimation, seed reconstruction, and seeds-to-TRUS registration. The updated seed positions allow the physician to assess the quality of implantation and dynamically adjust the treatment plan during the course of surgery to achieve improved exit dosimetry. Results: The system was tested on 10 phantoms and 37 patients. Seed segmentation resulted in a 1% false negative and 2% false positive rates. Fiducial detection with pose estimation resulted in a detection rate of 98%. Seed reconstruction had a mean reconstruction error of 0.4 mm. Seeds-to-TRUS registration had a mean registration error of 1.3 mm. The total processing time from image acquisition to registration was approximately 1 minute. Conclusion: We present an image-guidance system for intraoperative dynamic dosimetry in prostate brachytherapy. Using standard imaging equipments and a simple fiducial, our system can be easily adopted in any clinics. Robust image processing algorithms enable accurate and fast computation of the delivered dose. Especially, the system enables detection of possible hot/cold spots during the surgery, allowing the physician to address these in the operating room rather than requiring additional therapy afterwards. This research was supported in part by the National Institutes of Health/National Cancer Institute (NIH/NCI) under grant 2R44CA099374 and grant 1R01CA151395, and in part by the Department of Defense (DoD) under grant W81XWH-05-1-0407.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compressed/reconstructed test images for CRAF/Cassini

A set of compressed, then reconstructed, test images submitted to the Comet Rendezvous Asteroid Flyby (CRAF)/Cassini project is presented as part of its evaluation of near lossless high compression algorithms for representing image data. A total of seven test image files were provided by the project. The seven test images were compressed, then reconstructed with high quality (root mean square error of approximately one or two gray levels on an 8 bit gray scale), using discrete cosine transforms or Hadamard transforms and efficient entropy coders. The resulting compression ratios varied from about 2:1 to about 10:1, depending on the activity or randomness in the source image. This was accomplished without any special effort to optimize the quantizer or to introduce special postprocessing to filter the reconstruction errors. A more complete set of measurements, showing the relative performance of the compression algorithms over a wide range of compression ratios and reconstruction errors, shows that additional compression is possible at a small sacrifice in fidelity.

Dolinar, S.↗

Well-balanced Component-wise Scheme for Shallow Water System

This paper presents a well-balanced numerical scheme for solving free surface flows involving wetting and drying. The proposed algorithm combines a component-wise approach with hydrostatic reconstruction strategy to compute flows over wet or dry surfaces and to satisfy the steady state condition of still water. The robustness of the proposed scheme is verified under several benchmark hydraulic tests.

42 ENGINEERING↗

Plasma boundary shape control and real-time equilibrium reconstruction on NSTX-U

The upgrade to the National Spherical Torus eXperiment (NSTX-U) included two main improvements: a larger center-stack, enabling higher toroidal field and longer pulse duration, and the addition of three new tangentially aimed neutral beam sources, which increase available heating and current drive, and allow for flexibility in shaping power, torque, current, and particle deposition profiles. To best use these new capabilities and meet the high-performance operational goals of NSTX-U, major upgrades to the NSTX-U Control System (NCS) hardware and software have been made. Several control algorithms, including those used for real-time equilibrium reconstruction and shape control, have been upgraded to improve and extend plasma control capabilities. As part of the commissioning phase of first plasma operations, the shape control system was tuned to control the boundary in both inner-wall limited and diverted discharges. It has been used to accurately track the requested evolution of the boundary (including the size of the inner gap between the plasma and central solenoid, which is a challenge for the ST configuration), X-point locations, and strike point locations, enabling repeatable discharge evolutions for scenario development and diagnostic commissioning.

Boyer, M↗

Maximum Likelihood Expectation-Maximization Algorithms Applied to Localization and Identification of Radioactive Sources with Recent Coded Mask Gamma Cameras

In this work, we tested Maximum likelihood expectation-maximization (MLEM) algorithms optimized for gamma imaging applications on two recent coded mask gamma cameras. We respectively took advantage of the characteristics of the GAMPIX and Caliste HD-based gamma cameras: noise reduction thanks to mask/anti-mask procedure but limited energy resolution for GAMPIX, high energy resolution for Caliste HD. One of our short-term perspectives is the test of MAPEM algorithms integrating specific prior values for the data to reconstruct adapted to the gamma imaging topic. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma boundary shape control and real-time equilibrium reconstruction on NSTX-U

Here, the upgrade to the National Spherical Torus eXperiment (NSTX-U) included two main improvements: a larger center-stack, enabling higher toroidal field and longer pulse duration, and the addition of three new tangentially aimed neutral beam sources, which increase available heating and current drive, and allow for flexibility in shaping power, torque, current, and particle deposition profiles. To best use these new capabilities and meet the high-performance operational goals of NSTX-U, major upgrades to the NSTX-U control system (NCS) hardware and software have been made. Several control algorithms, including those used for real-time equilibrium reconstruction and shape control, have been upgraded to improve and extend plasma control capabilities. As part of the commissioning phase of first plasma operations, the shape control system was tuned to control the boundary in both inner-wall limited and diverted discharges. It has been used to accurately track the requested evolution of the boundary (including the size of the inner gap between the plasma and central solenoid, which is a challenge for the ST configuration), X-point locations, and strike point locations, enabling repeatable discharge evolutions for scenario development and diagnostic commissioning.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low energy muon neutrino reconstruction in MicroBooNE

MicroBooNE is a Liquid Argon Time Projection Chamber (LArTPC) neutrino experiment on the Booster Neutrino Beamline at the Fermi National Accelerator Laboratory, with an 85-tonne active mass. One of MicroBooNE’s primary physics goals is to investigate the excess of electron neutrino events seen by MiniBooNE in the [200-600] MeV range. MicroBooNE will constrain the intrinsic electron neutrino component of the beam by measuring the muon neutrino spectrum. Several low-energy excess analyses are taking place in parallel, using independent reconstructions and selection schemes. This paper will focus on a low-energy excess analysis that makes use of deep learning algorithms applied to the high-resolution images provided by the MicroBooNE LArTPC. We present a novel 3D event reconstruction based on computer vision tools and a stochastic search algorithm, yielding a 2.2% energy resolution for 1μ1p muon neutrino interactions in the [200-1500] MeV range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement and QCD analysis of double-differential inclusive jet cross sections in pp collisions at $ \sqrt{s}=8 $ TeV and cross section ratios to 2.76 and 7 TeV

A measurement of the double-differential inclusive jet cross section as a function of the jet transverse momentum p$_{T}$ and the absolute jet rapidity |y| is presented. Data from LHC proton-proton collisions at $ \sqrt{s}=8 $ TeV, corresponding to an integrated luminosity of 19.7 fb$^{−1}$, have been collected with the CMS detector. Jets are reconstructed using the anti-k$_{T}$ clustering algorithm with a size parameter of 0.7 in a phase space region covering jet p$_{T}$ from 74 GeV up to 2.5 TeV and jet absolute rapidity up to |y| = 3.0. The low-p$_{T}$ jet range between 21 and 74 GeV is also studied up to |y| = 4.7, using a dedicated data sample corresponding to an integrated luminosity of 5.6 pb$^{−1}$. The measured jet cross section is corrected for detector effects and compared with the predictions from perturbative QCD at next-to-leading order (NLO) using various sets of parton distribution functions (PDF). Cross section ratios to the corresponding measurements performed at 2.76 and 7 TeV are presented. From the measured double-differential jet cross section, the value of the strong coupling constant evaluated at the Z mass is α$_{S}$(M$_{Z}$) = 0.1164$_{− 0.0043}^{+ 0.0060}$ , where the errors include the PDF, scale, nonperturbative effects and experimental uncertainties, using the CT10 NLO PDFs. Improved constraints on PDFs based on the inclusive jet cross section measurement are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advanced functionality for radio analysis in the Offline software framework of the Pierre Auger Observatory

The advent of the Auger Engineering Radio Array (AERA) necessitates the development of a powerful framework for the analysis of radio measurements of cosmic ray air showers. As AERA performs 'radio-hybrid' measurements of air shower radio emission in coincidence with the surface particle detectors and fluorescence telescopes of the Pierre Auger Observatory, the radio analysis functionality had to be incorporated in the existing hybrid analysis solutions for fluorescence and surface detector data. This goal has been achieved in a natural way by extending the existing Auger Offline software framework with radio functionality. In this article, we lay out the design, highlights and features of the radio extension implemented in the Auger Offline framework. Its functionality has achieved a high degree of sophistication and offers advanced features such as vectorial reconstruction of the electric field, advanced signal processing algorithms, a transparent and efficient handling of FFTs, a very detailed simulation of detector effects, and the read-in of multiple data formats including data from various radio simulation codes. The source code of this radio functionality can be made available to interested parties on request.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neural network reconstruction of the DIII-D tokamak plasma boundary using a reduced set of diagnostics

This study investigates the feasibility of reconstructing the last closed flux surface in the DIII-D tokamak using neural network models trained on reduced input feature sets, addressing an ill-posed task. Two models are compared: one trained solely on coil currents and another incorporating coil currents, plasma current and loop voltage. The model trained exclusively on coil currents achieved a mean point displacement of $0.04$ m on a held-out test set, while the inclusion of plasma current and loop voltage reduced the error to $0.03$ m. This comparison highlights the trade-offs between input feature complexity and reconstruction accuracy, demonstrating the potential of machine learning algorithms to perform effectively in data-limited environments, such as those expected in fusion power plants due to diagnostic constraints imposed by the presence of blankets and shielding.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗