Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Reliable automatic alignment of tomographic projection data by passive auto-focus

Purpose: The authors present a robust algorithm that removes the blurring and double-edge artifacts in high-resolution computed tomography (CT) images that are caused by misaligned scanner components. This alleviates the time-consuming process of physically aligning hardware, which is of particular benefit if components are moved or swapped frequently. Methods: The proposed method uses the experimental data itself for calibration. A parameterized model of the scanner geometry is constructed and the parameters are varied until the sharpest 3D reconstruction is found. The concept is similar to passive auto-focus algorithms of digital optical instruments. The parameters are used to remap the projection data from the physical detector to a virtual aligned detector. This is followed by a standard reconstruction algorithm, namely the Feldkamp algorithm. Feldkamp et al.[J. Opt. Soc. Am. A 1, 612-619 (1984)]. Results: An example implementation is given for a rabbit liver specimen that was collected with a circular trajectory. The optimal parameters were determined in less computation time than that for a full reconstruction. The example serves to demonstrate that (a) sharpness is an appropriate measure for projection alignment, (b) our parameterization is sufficient to characterize misalignments for cone-beam CT, and (c) the procedure determines parameter values with sufficient precision to remove the associated artifacts. Conclusions: The algorithm is fully tested and implemented for regular use at The Australian National University micro-CT facility for both circular and helical trajectories. It can in principle be applied to more general imaging geometries and modalities. It is as robust as manual alignment but more precise since we have quantified the effect of misalignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conditions for reliable time-resolved dosimetry of electronic portal imaging devices for fixed-gantry IMRT and VMAT

Purpose: The continuous scanning mode of electronic portal imaging devices (EPID) that offers time-resolved information has been newly explored for verifying dynamic radiation deliveries. This study seeks to determine operating conditions (dose rate stability and time resolution) under which that mode can be used accurately for the time-resolved dosimetry of intensity-modulated radiation therapy (IMRT) beams.Methods: The authors have designed the following test beams with variable beam holdoffs and dose rate regulations: a 10 Multiplication-Sign 10 cm open beam to serve as a reference beam; a sliding window (SW) beam utilizing the motion of a pair of multileaf collimator (MLC) leaves outside the 10 Multiplication-Sign 10 cm jaw; a step and shoot (SS) beam to move the pair in step; a volumetric modulated arc therapy (VMAT) beam. The beams were designed in such a way that they all produce the same open beam output of 10 Multiplication-Sign 10 cm. Time-resolved ion chamber measurements at isocenter and time-resolved and integrating EPID measurements were performed for all beams. The time-resolved EPID measurements were evaluated through comparison with the ion chamber and integrating EPID measurements, as the latter are accepted procedures. For two-dimensional, time-resolved evaluation, a VMAT beam with an infield MLC travel was designed. Time-resolved EPID measurements and Monte Carlo calculations of such EPID dose images for this beam were performed and intercompared.Results: For IMRT beams (SW and SS), the authors found disagreement greater than 2%, caused by frame missing of the time-resolved mode. However, frame missing disappeared, yielding agreement better than 2%, when the dose rate of irradiation (and thus the frame acquisition rates) reached a stable and planned rate as the dose of irradiation was raised past certain thresholds (a minimum 12 s of irradiation per shoot used for SS IMRT). For VMAT, the authors found that dose rate does not affect the frame acquisition rate, thereby causing no frame missing. However, serious inplanar nonuniformities were found. This could be overcome by sacrificing temporal resolution (10 frames or 0.95 s/image): the continuous images agreed with ion chamber responses at the center of EPID and the calculation two-dimensionally in a time-resolved manner.Conclusions: The authors have determined conditions under which the continuous mode can be used for time-resolved dosimetry of fixed-gantry IMRT and VMAT and demonstrated it for VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-598: Parametric Equation for Quick and Reliable Estimate of Stray Neutron Doses in Proton Therapy and Application for Intracranial Tumor Treatments

Purpose: Development of a parametric equation suitable for a daily use in routine clinic to provide estimates of stray neutron doses in proton therapy. Methods: Monte Carlo (MC) calculations using the UF-NCI 1-year-old phantom were exercised to determine the variation of stray neutron doses as a function of irradiation parameters while performing intracranial treatments. This was done by individually changing the proton beam energy, modulation width, collimator aperture and thickness, compensator thickness and the air gap size while their impact on neutron doses were put into a single equation. The variation of neutron doses with distance from the target volume was also included in it. Then, a first step consisted in establishing the fitting coefficients by using 221 learning data which were neutron absorbed doses obtained with MC simulations while a second step consisted in validating the final equation. Results: The variation of stray neutron doses with irradiation parameters were fitted with linear, polynomial, etc. model while a power-law model was used to fit the variation of stray neutron doses with the distance from the target volume. The parametric equation fitted well MC simulations while establishing fitting coefficients as the discrepancies on the estimate of neutron absorbed doses were within 10%. The discrepancy can reach ∼25% for the bladder, the farthest organ from the target volume. Finally, the validation showed results in compliance with MC calculations since the discrepancies were also within 10% for head-and-neck and thoracic organs while they can reach ∼25%, again for pelvic organs. Conclusion: The parametric equation presents promising results and will be validated for other target sites as well as other facilities to go towards a universal method.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-433: Evaluation of a New Dose Mimicking Application for Clinical Flexibility and Reliability

Purpose: Clinical workflow and machine down time occasionally require patients to be temporarily treated on a system other than the initial treatment machine. A new commercial dose mimicking application provides automated cross-platform treatment planning to expedite this clinical flexibility. The aim of this work is to evaluate the feasibility of automatic plan creation and establish a robust clinical workflow for prostate and pelvis patients. Methods: Five prostate and five pelvis patients treated with helical plans were selected for re-planning with the dose mimicking application, covering both simple and complex scenarios. Two-arc VMAT and 7- and 9-field IMRT plans were generated for each case, with the objective function of achieving similar dose volume histogram from the initial helical plans. Dosimetric comparisons include target volumes and organs at risk (OARs) (rectum, bladder, small bowel, femoral heads, etc.). Dose mimicked plans were evaluated by a radiation oncologist, and patient-specific QAs were performed to validate delivery. Results: Overall plan generation and transfer required around 30 minutes of dosimetrist’s time once the dose-mimicking protocol is setup for each site. The resulting VMAT and 7- and 9-field IMRT plans achieved equivalent PTV coverage and homogeneity (D99/DRx = 97.3%, 97.2%, 97.2% and HI = 6.0, 5.8, and 5.9, respectively), compared to helical plans (97.6% and 4.6). The OAR dose discrepancies were up to 6% in rectum Dmean, but generally lower in bladder, femoral heads, bowel and penile bulb. In the context of 1–5 fractions, the radiation oncologist evaluated the dosimetric changes as not clinically significant. All delivery QAs achieved >90% pass with a 3%/3mm gamma criteria. Conclusion: The automated dose-mimicking workflow offers a strategy to avoid missing treatment fractions due to machine down time with non-clinically significant changes in dosimetry. Future work will further optimize dose mimicking plans and investigate other cross-platform treatment delivery options.

60 APPLIED LIFE SCIENCES↗

Estimation of the efficiency of the introduction of a porous layer into a silicon-on-sapphire structure substrate to enhance the reliability of devices under irradiation

We investigate the efficiency of the introduction of a porous layer into the substrate of a silicon-onsapphire structure by the implantation of He ions to enhance the radiation resistance of devices. The properties of the introduced layer and its parameters affecting the concentration of minority charge carriers generated by irradiation are analyzed. The reported results of the analysis and calculations can be used to optimize He-ion implantation conditions during the formation of a porous layer.

36 MATERIALS SCIENCE↗

Avoiding Pitfalls in the Determination of Reliable Electrochemical Kinetics Parameters for the Cu 2+ → Cu 1+ Reduction Reaction in Deep Eutectic Solvents

Deep eutectic solvents (DES), on account of their low-cost, non-flammability and electrochemical stability, are attracting attention for their potential use in applications such as electrodeposition and energy storage. In these applications, knowledge of the transport and electrochemical kinetics properties of DES is critically important. To date, attempts to measure the kinetics parameters of the Cu 2+ + e ⇌ Cu 1+ reaction in ethaline DES have yielded a cathodic charge transfer coefficient (α) in the range of 0.2–0.3 suggesting an unexpected asymmetric polarization behavior. In the present work, we pursued a comprehensive study of the kinetics and transport properties of the aforementioned reaction. Using steady-state and transient polarization measurements on RDE and microelectrodes combined with diffusion-reaction modeling, we demonstrate that the Cu 2+ /Cu 1+ transition exhibits a charge transfer coefficient in the range of 0.49–0.54 and an exchange current density in the range 1.72–1.88 mA/cm 2 . Recommendations are provided for avoiding pitfalls in kinetics analysis of highly resistive DES electrolytes. These recommendations include the application of accurate $IR_Ω$ correction and the use of electrode configurations where the secondary current distribution is relatively uniform.

25 ENERGY STORAGE↗

Grid Reliability Statistics [SWR-25-45]

This codebase houses a suite of statistical and descriptive analyses of NERC GADS data of interest to grid modelers and planners. This repository is envisioned to house a collection of statistical and descriptive summaries of NERC GADS data, particularly summaries that on their own might be insufficient to warrant publication. In addition, it is intended to disseminate results rather than to enable reproduction as GADS is non-public.

Murphy, Sinnott [National Renewable Energy Laborat↗

First-Order Individual Gas Sensors as Next Generation Reliable Analytical Instruments

It is conventionally expected that the performance of existing gas sensors may degrade in the field compared to laboratory conditions because (i) a sensor may lose its accuracy in the presence of chemical interferences and (ii) variations of ambient conditions over time may induce sensor-response fluctuations (i.e., drift). Breaking this status quo in poor sensor performance requires understanding the origins of design principles of existing sensors and bringing new principles to sensor designs. Existing gas sensors are single-output (e.g., resistance, electrical current, light intensity, etc.) sensors, also known as zero-order sensors (Karl Booksh and Bruce R. Kowalski, Analytical Chemistry, DOI: 10.1021/ac00087a718). Any zero-order sensor is undesirably affected by variable chemical background and sensor drift that cannot be distinguished from the response to an analyte. To address these limitations, we are developing multivariable gas sensors with independent responses, which are first-order analytical instruments. Here, we demonstrate self-correction against drift in two types of first-order gas sensors that operate in different portions of the electromagnetic spectrum. Our radiofrequency sensors utilize dielectric excitation of semiconducting metal oxide materials on the shoulder of their dielectric relaxation peak and achieve self-correction of the baseline drift by operation at several frequencies. Our photonic sensors utilize nanostructured sensing materials inspired by Morpho butterflies and achieve self-correction of the baseline drift by operation at several wavelengths. These principles of self-correction for drift effects in first-order sensors open opportunities for diverse emerging monitoring applications that cannot afford frequent periodic maintenance that is typical of traditional analytical instruments.

Potyrailo, Radislav A.↗

Dataset for Top Model Decision Tree: Selecting Segmentation Models for Reliable Quantitative Analysis in Low- and Ultralow-Dose CryoEM

Motivation Multiple deep learning model architectures can be used to segment bacterial membranes in cryoEM images. However, an AI-based tool advancement is often presented with only a single segmentation model for broad use, and this single model may show inconsistent results across datasets from different users. Here, we present the Top Model Decision Tree, a model screening framework to screen for the best model to generate bacterial inner and outer membrane masks based on user priorities. We use pre-trained segmentation models from YOLOv11, YOLO26, U-Net, Detectron2 and SAM3 fine-tuned on bacterial inner and outer membranes imaged with cryoEM. Run the Framework This notebook must be opened in Google Colab. Mount Google Drive and run with a GPU-based runtime. Open the notebook and follow steps to git clone in folders and files within this repository. There will be a repeating top_model_decision_tree.ipynb (notebook clone) that will not be used. Save your .png binary mask files and .csv table outputs within your Google Drive or download before closing the notebook. The models and all analysis/training scripts are available at [GitHub: https://github.com/Lynnicia/CryoEM_membranes_top_model_decision_tree and https://github.com/Sireesiru/Semantic-Segmentation-of-bacterial-cell-envelope-using-U-Nets.

59 BASIC BIOLOGICAL SCIENCES↗

Digital risk analysis in nuclear engineering projects: Designing for safety, performance, reliability, and security

Cyber-informed engineering and security-by-design frameworks are important in promoting the need to identify cybersecurity concerns early in the systems engineering lifecycle so risks from adversarial cyber-attacks can be eliminated or reduced through engineering design practices. In addition to adversarial risk, risk in operational technology systems also includes non-adversarial and unintentional risk from other factors such as human performance errors, environmental conditions, design flaws, and device degradation or failure. This paper introduces a new concept for characterizing digital risk, both adversarial and non-adversarial, and provides the basis for initial research into a novel digital risk analysis approach focused on incorporating attack difficulty into a multi-attribute analysis technique using robust decision-making. This digital risk characterization is also used to frame a discussion on the challenges of competing objectives and competing stakeholder requirements in an integrated energy system project that incorporates a small modular reactor and industrial facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spot-Checking for Reliable Quantum Communications

We demonstrate a spot-checking approach for real-time drift estimation and mitigation in continuously operating quantum links. Using polarization-entangled photon pairs, we achieve stable 16-hour operation, validating efficient, minimally invasive monitoring of quantum-network performance.

Zhang, Yanbao [ORNL] (ORCID:0000000245530561)↗

Integration of phage and yeast display platforms: A reliable and cost effective approach for binning of peptides as displayed on-phage

Hundreds of target specific peptides are routinely discovered by peptide display platforms. However, due to the high cost of peptide synthesis only a limited number of peptides are chemically made for further analysis. Here we describe an accurate and cost effective method to bin peptides on-phage based on binding region(s), without any requirement for peptide or protein synthesis. This approach, which integrates phage and yeast display platforms, requires display of target and its alanine variants on yeast. Flow cytometry was used to detect binding of peptides on-phage to the target on yeast. Once hits were identified, they were synthesized to confirm their binding region(s) by HDX (Hydrogen deuterium exchange) and crystallography. Moreover, we have successfully shown that this approach can be implemented as part of a panning process to deplete non-functional peptides. This technique can be applied to any target that can be successfully displayed on yeast; it narrows down the number of peptides requiring synthesis; and its utilization during selection results in enrichment of peptide population against defined binding regions on the target.

59 BASIC BIOLOGICAL SCIENCES↗