Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Ground-based simulations of cosmic ray heavy ion interactions in spacecraft and planetary habitat shielding materials

This paper surveys some recent accelerator-based measurements of the nuclear fragmentation of high energy nuclei in shielding and tissue-equivalent materials. These data are needed to make accurate predictions of the radiation field produced at depth in spacecraft and planetary habitat shielding materials and in the human body by heavy charged particles in the galactic cosmic radiation. Projectile-target combinations include 1 GeV/nucleon 56Fe incident on aluminum and graphite and 600 MeV/nucleon 56Fe and 290 MeV/nucleon 12C on polyethylene. We present examples of the dependence of fragmentation on material type and thickness, of a comparison between data and a fragmentation model, and of multiple fragments produced along the beam axis.

NASA Discipline Radiation Health↗

Multilayer Dielectric Transmissive Optical Phase Modulator

A multilayer dielectric device has been fabricated as a prototype of a low-loss, low-distortion, transmissive optical phase modulator that would provide as much as a full cycle of phase change for all frequency components of a transmitted optical pulse over a frequency band as wide as 6.3 THz. Arrays of devices like this one could be an alternative to the arrays of mechanically actuated phase-control optics (adaptive optics) that have heretofore been used to correct for wave-front distortions in highly precise optical systems. Potential applications for these high-speed wave-front-control arrays of devices include agile beam steering, optical communications, optical metrology, optical tracking and targeting, directional optical ranging, and interferometric astronomy. The device concept is based on the same principle as that of band-pass interference filters made of multiple dielectric layers with fractional-wavelength thicknesses, except that here there is an additional focus on obtaining the desired spectral phase profile in addition to the device s spectral transmission profile. The device includes a GaAs substrate, on which there is deposited a stack of GaAs layers alternating with AlAs layers, amounting to a total of 91 layers. The design thicknesses of the layers range from 10 nm to greater than 1 micrometer. The number of layers and the thickness of each layer were chosen in a computational optimization process in which the wavelength dependences of the indices of refraction of GaAs and AlAs were taken into account as the design was iterated to maximize the transmission and minimize the group-velocity dispersion for a wavelength band wide enough to include all significant spectral components of the pulsed optical signal to be phase modulated.

Keys, Andrew Scott↗

Clast Selection and Metallographic Cooling Rates: Initial Results on Type 1A and 2A Mesosiderites

We initiated a comprehensive study on selected clasts and metal of mesosiderites using SEM, electron microprobe and the complete suite of noble gases. Here we report initial results on the petrography of selected clasts and metallographic cooling rates using the central Ni method used in sev-eral publications. We focus on the approach of selecting grains in least recrystallized mesosiderites. Hence, especially (lithic) clasts in type 1A, 1B, 2A and 2B are the first choice. They provide highest primitive-ness and least annealing/metamorphism. All grains selected should be in close proximity to each other. Lithic clasts in mesosiderites are of high interest be-cause of their igneous texture and similarity to eucrites and howardite petrography. We find pyrox-enes (px) and plagioclase (plag) attached to each other which implies a common formation history. It will be interesting to see differences and similarities in their noble gas inventory (CRE ages, trapped components and closure temperature). In addition, we will investi-gate variations of the lithic clasts toward similar grains in the thick sections which are not igneous. Plag grains are the best bases for noble gas measurements con-cerning He to Ar and Ar-Ar dating since it delivers im-portant target elements. We focus on plag grains in close contact to olivine (olv) / px grains to assess weth-er both grains show noble gas patterns being similar or different. Phosphate grains are suitable for Kr and Xe measurements since they yield REE abundances (tar-get elements).

Mesosiderites↗

Comparison of Thermal Diffusivity Degradation of Irradiated Zirlo and SiC-SiC Composite

Zirlo (Zircaloy cladding material from Westinghouse) has been widely used as the fuel cladding material in Light Water Reactors because of its high melting point, low susceptibility to corrosion, good thermal and mechanical shock resistance, and low degradation of mechanical properties under irradiation. But as Zirlo reacts with water at high temperature, which can trigger serious accidents, efforts have been made to explore better candidates to replace Zirlo in the water-cooled reactors. SiC-SiC composite is considered as one of the most viable options due to its comparable mechanical performances and corrosion resistance. However, one of the most important properties, thermal diffusivities of both Zirlo and SiC-SiC composite, and their degradation after irradiation, are not well known yet. Ion-irradiated samples are used to study the thermal property degradation caused by irradiation instead of the neutron-irradiated ones due to the significantly lower radioactivity. The microstructural damage is estimated from the software simulation SRIM/TRIM based on the energy and fluence of the ion, and the target material, and represented by DPA (displacement by atom). Different from neutron-irradiated samples, the damaged layer of ion-irradiated samples is only a few to a few tens of micrometers thick, and the damage is depth dependent. It is impossible to directly measure the bulk property change, and a microscale measurement technique is necessary. Laser-based photothermal reflectance technique is one of the ideal methods to measure local thermal conductivity and diffusivity with high spatial resolution. The main principle of this technique is to heat the solid sample using an intensity-modulated laser, and scan the sample with a constant intensity continuous-wave (CW) laser to detect the thermal wave propagation. On bulk, isotropic material, if the heating laser intensity is modulated as a sine wave, thermal diffusivity of the sample can be derived from the phase lag of the thermal wave, scan distance and modulation frequency in a straight forward manner. By using more specific analytical models, thermal conductivity and diffusivity in complicated cases, such as layered structure materials, composite materials, and/or anisotropic materials, are measurable as well. In this work, thermal diffusivity of the light damage layer of the post-irradiation Zirlo and SiC-SiC composite are measured and compared. The Zirlo sample is irradiated by Ni{sup 9+} ion, and SiC-SiC composite material is irradiated by Si{sup 7+} ion. The peak DPA of both sample is similar as ∼10. For ion-irradiated materials, DPA is known to increase with depth before it reaches the peak, and then sharply drop to zero. In term of light damage layer in this manuscript, we mean by the layer with a DPA smaller than 5% maximum value. In this layer DPA increases slowly and smoothly with depth, and the structure and thus thermal properties are more spatially uniform. For the SiC-SiC composite, the measurements are separately conducted on fibers along radial or axial direction, and on the matrix. Our measurement results show that with similar microstructural damage, thermal diffusivity of matrix SiC reduces more significantly than that of Zirlo. For fiber SiC that has a much lower thermal diffusivity than the matrix SiC before irradiation, the post-irradiation effect on thermal diffusivity is not obvious.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tomographic imaging of a target directly irradiated in experiments on the Iskra-5 iodine laser facility

We set forth the data of experiments involving direct microtarget irradiation by the 12 second-harmonic beams ({lambda} = 0.66 {mu}m) of iodine laser radiation carried out on the Iskra-5 facility. For microtargets we employed glass shells {approx}500 {mu}m in diameter with {approx}1-{mu}m thick walls, which were filled with a DT mixture at a pressure p{sub DT} {approx} 3-4 atm. In one of these experiments, a tomographic image of the microtarget was recorded from the images obtained using pinhole cameras, which were arranged along seven different directions. The pinhole images were acquired in the X-ray radiation with photon energies above 1.5 keV. The procedure used for reconstructing the volume luminosity of the microtarget is described. An analysis of the tomographic image suggests that the compressed microtarget domain possesses a complex asymmetric shape; 20-30 {mu}m sized structural elements being clearly visible. The resultant data set allowed us to estimate the initial nonuniformity of microtarget surface irradiation by the laser radiation. The rms nonuniformity of microtarget irradiance was estimated at {approx}60 %. (interaction of laser radiation with targets)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retrieval of Aerosol Optical Properties Using MERIS Observations: Algorithm and Some First Results

The MEdium Resolution Imaging Spectrometer (MERIS) instrument on board ESA Envisat made measurements from 2002 to 2012. Although MERIS was limited in spectral coverage, accurate Aerosol Optical Thickness (AOT) from MERIS data are retrieved by using appropriate additional information. We introduce a new AOT retrieval algorithm for MERIS over land surfaces, referred to as eXtensible Bremen AErosol Retrieval (XBAER). XBAER is similar to the dark-target (DT) retrieval algorithm used for Moderate-resolution Imaging Spectroradiometer (MODIS), in that it uses a lookup table (LUT) to match to satellite-observed reflectance and derive the AOT. Instead of a global parameterization of surface spectral reflectance, XBAER uses a set of spectral coefficients to prescribe surface properties. In this manner, XBAER is not limited to dark surfaces (vegetation) and retrieves AOT over bright surface (desert, semiarid, and urban areas). Preliminary validation of the MERIS-derived AOT and the ground-based Aerosol Robotic Network (AERONET) measurements yield good agreement, the resulting regression equation is y (0.92 x +/- 0.07) + (0.05 +/- 0.01) and Pearson correlation coefficient of R 0.78. Global monthly means of AOT have been compared from XBAER, MODIS and other satellite-derived datasets.

satellite retrievals↗

Pressure/temperature fluid cell apparatus for the neutron powder diffractometer instrument: Probing atomic structure in situ

This contribution describes a new local structure compatible gas/liquid cell apparatus for probing disordered materials at high pressures and variable temperatures in the Neutron Powder Diffraction instrument at the Lujan Neutron Scattering Center, Los Alamos National Laboratory. The new sample environment offers choices for sample canister thickness and canister material type. Finite element modeling is utilized to establish maximum allowable working pressures of 414 MPa at 15 K and 121 MPa at 600 K. High quality atomic pair distribution function data extraction and modeling have been demonstrated for a calibration standard (Si powder) and for supercritical and subcritical CO 2 measurements. As a result, the new sample environment was designed to specifically target experimental studies of the local atomic structures involved in geologic CO 2 sequestration, but will be equally applicable to a wide variety of energy applications, including sorption of fluids on nano/meso-porous solids, clathrate hydrate formation, catalysis, carbon capture, and H 2 and natural gas uptake/storage.

36 MATERIALS SCIENCE↗

Reduced Cu(InGa)Se 2 Thickness in Solar Cells Using a Superstrate Configuration

This project by the Institute of Energy Conversion (IEC) and the Department of Electrical and Computer Engineering at the University of Delaware sought to develop the technology and underlying science to enable reduced cost of Cu(InGa)Se 2 manufacturing by reducing the thickness of the Cu(InGa)Se 2 absorber layer by half compared to typical production. The approach to achieve this was to use the superstrate cell configuration in which light is incident on the cell through the glass. This structure facilitates optical enhancement approaches needed to achieve high efficiency with Cu(InGa)Se 2 thicknesses less than 1 µm. The primary objective was to demonstrate a Cu(InGa)Se 2 cell with absorber thickness 0.5 - 0.7 µm and 17% efficiency, along with a quantitative loss analysis to define a pathway to 20% efficiency. Additional objectives were the development of stable TCO and buffer layers or contact layers to withstand the Cu(InGa)Se 2 deposition temperature and of advanced optical enhancement methods. The underlying fundamental science needed to effectively transition these outcomes to large scale was addressed by extensive materials and device characterization and by development of comprehensive optical models. Two different superstrate configurations have been investigated. A frontwall cell is illuminated through the glass to the primary front junction of the device. This configuration has been used for previous efforts on superstrate Cu(InGa)Se 2 but performance has been limited by interdiffusion or reaction with CdS or other buffer layers. In this project, several approaches to overcome these limitations were explored using CdS, ZnO and ZnSe buffer layers. In each case, mechanisms that limit device performance were identified using detailed characterization of the materials and junctions. Due to the junction formation difficulties, efforts were concentrated on a new backwall configuration in which light is incident through the substrate into the back of the absorber layer. The primary junction is then formed after Cu(InGa)Se 2 deposition. This allows the potential benefits of superstrate cells for optical enhancement while maintaining processing advantages of the substrate configuration and avoiding the harmful effects of high temperature deposition on p-n junction formation. Backwall devices have outperformed substrate cells at absorber thicknesses of 0.1-0.5 µm through enhanced JSC due to easy incorporation of a Ag reflector and, with light incident on the absorber, the elimination of parasitic absorption in the CdS buffer. An efficiency of 9.7% has been achieved for a backwall Cu(InGa)Se 2 device with absorber thickness ~0.4 μm. A critical achievement that enabled implementation of the backwall cell was the development of a transparent back contact using MoO 3 or WO 3 . Processes for controlled deposition of each material by reactive rf sputtering from metal targets were developed. These contacts have wide bandgaps making them well-suited for application as contacts for backwall devices as well as potential use in bifacial cells and as the top cell of tandem CuInSe 2 -based devices. Optical enhancement will be critical for further improvements. Wet chemical texturing of ZnO films has been developed for a simple, low cost light-trapping scheme for backwall superstrate devices to enhance long wavelength quantum efficiency. An aqueous oxalic acid etch was developed and found to strongly texture sputtered ZnO with high haze ≈ 0.9 observed across the whole spectrum. And finally, advanced optical models have been developed to assist the characterization and optimization of Cu(InGa)Se 2 cells with thin absorbers

14 SOLAR ENERGY↗

High energy X-ray pinhole imaging at the Z facility

A new high photon energy (hν > 15 keV) time-integrated pinhole camera (TIPC) has been developed as a diagnostic instrument at the Z facility. This camera employs five pinholes in a linear array for recording five images at once onto an image plate detector. Each pinhole may be independently filtered to yield five different spectral responses. The pinhole array is fabricated from a 1-cm thick tungsten block and is available with either straight pinholes or conical pinholes. Each pinhole within the array block is 250 μm in diameter. The five pinholes are splayed with respect to each other such that they point to the same location in space, and hence present the same view of the radiation source at the Z facility. The fielding distance from the radiation source is 66 cm and the nominal image magnification is 0.374. Initial experimental results from TIPC are shown to illustrate the performance of the camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding the effects of laser imprint on plastic-target implosions on OMEGA

Understanding the effects of laser imprint on target performance is critical to the success of direct-drive inertial confinement fusion. Directly measuring the disruption caused by laser imprints to the imploding shell and hot-spot formation, in comparison with multidimensional radiation–hydrodynamic simulations, can provide a clear picture of how laser nonuniformities cause target performance to degrade. With the recently developed x-ray self-emission imaging technique and the state-of-the-art physics models recently implemented in the two-dimensional hydrocode DRACO , a systematic study of laser-imprint effects on warm target implosions on OMEGA has been performed using both experimental results and simulations. By varying the laser-picket intensity, the imploding shells were set at different adiabats (from α = 2 to α = 6). As the shell adiabats decreased, it was observed that (1) the measured shell thickness at the time the hot spot lit up became larger than the uniform one-dimensional (1-D) predictions; (2) the hot-spot core emitted earlier than the corresponding 1-D predictions; (3) the measured neutron yield first increased then decreased as the shell adiabat α was reduced; and (4) the hot-spot size reduced as α decreased for cases where SSD (smoothing by spectral dispersion) was on but became larger for low-α shots in cases where SSD was off. Most of these experimental observations are well reproduced by DRACO simulations with laser imprints including modes up to λ max = 200. In addition, these studies identify the importance of laser imprint as the major source of degrading target performance for OMEGA implosions of adiabat α ≤ 3. Mitigating laser imprints is required to improve low-α target performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The AMORE Protocol for Advanced-Stage and Recurrent Nonorbital Rhabdomyosarcoma in the Head-and-Neck Region of Children: A Radiation Oncology View

Purpose: A multidisciplinary approach, consisting of consecutive Ablative Surgery, MOld technique with afterloading brachytherapy and immediate surgical REconstruction (AMORE) applied after chemotherapy, was designed for children with rhabdomyosarcoma in the head-and-neck region. Analysis of the first 42 patients was performed. Methods and Materials: After macroscopically radical tumor resection, molds were constructed for each individual to fit into the surgical defect. The molds, made of 5-mm-thick layers of thermoplastic rubber, consisted of different parts. Flexible catheters were positioned between layers. After brachytherapy, the molds were removed. Surgical reconstruction was performed during the same procedure. Results: Dose to the clinical target volume varied from 40 to 50 Gy for the primary treatment (31 patients) and salvage treatment groups (11 patients). There were 18 females and 24 males treated from 1993 until 2007. Twenty-nine tumors were located in the parameningeal region, and 13 were located in the nonparameningeal region. Patient age at the time of AMORE was 1.2-16.9 years (average, 6.5 years). Follow-up was 0.2-14.5 years (average, >5.5 years). Eleven patients died, 3 with local recurrence only, 6 with local and distant disease, 1 died of distant metastases only, and 1 patient died of a second primary tumor. Overall 5-year survival rates were 70% for the primary treatment group and 82% for the salvage group. Treatment was well tolerated, and acute and late toxicity were mild. Conclusions: The AMORE protocol yields good local control and overall survival rates, and side effects are acceptable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser ablation of metallic targets with high fluences: Self-consistent approach

Ablation of metallic target using Gaussian profile laser pulse with duration of 30 ns and fluence extending up to 100 J/cm{sup 2} is studied. A self-consistent model that involves numerical simulation to obtain the thickness of a hydrodynamic layer is proposed. The influence of the hydrodynamic layer thickness on Knudsen layer properties, and hence the rate of evaporation, is demonstrated. Self-consistent model is compared with model based on assumption about sonic speed at the Knudsen layer outer edge and validated with experimental results for Al alloy and Cu. Finally, sample calculations are performed using the proposed model to obtain depth of evaporation of Al alloy for single pulse duration.

36 MATERIALS SCIENCE↗

Atomic force microscopy studies of homoepitaxial GaN layers grown on GaN template by laser MBE

We have grown homoepitaxial GaN films on metal organic chemical vapor deposition (MOCVD) grown 3.5 µm thick GaN on sapphire (0001) substrate (GaN template) using an ultra-high vacuum (UHV) laser assisted molecular beam epitaxy (LMBE) system. The GaN films were grown by laser ablating a polycrystalline solid GaN target in the presence of active r.f. nitrogen plasma. The influence of laser repetition rates (10-30 Hz) on the surface morphology of homoepitaxial GaN layers have been studied using atomic force microscopy. It was found that GaN layer grown at 10 Hz shows a smooth surface with uniform grain size compared to the rough surface with irregular shape grains obtained at 30 Hz. The variation of surface roughness of the homoepitaxial GaN layer with and without wet chemical etching has been also studied and it was observed that the roughness of the film decreased after wet etching due to the curved structure/rough surface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A conservative approach to scaling magneto-inertial fusion concepts to larger pulsed-power drivers

The Magnetized Liner Inertial Fusion (MagLIF) experimental platform [M. R. Gomez et al., Phys. Rev. Lett. 113, 155003 (2014)] represents the most successful demonstration of magneto-inertial fusion (MIF) techniques to date in pursuit of ignition and significant fusion yields. The pressing question remains regarding how to scale MIF concepts like MagLIF to more powerful pulsed-power drivers while avoiding significant changes in physical regimes that could adversely impact performance. In this work, we propose a conservative approach for scaling general MIF implosions, including MagLIF. Underpinning our scaling approach is a theoretical framework describing the evolution of the trajectory and thickness of a thin-walled, cylindrical, current-driven shell imploding on preheated, adiabatic fuel. By imposing that scaled implosions remain self-similar, we obtain a set of scaling rules expressing key target design parameters and performance metrics as functions of the maximum driver current I max . We identify several scaling paths offering unique, complementary benefits and trade-offs in terms of physics risks and driver requirements. Remarkably, when scaling present-day experiments to higher coupled energies, these paths are predicted to preserve or reduce the majority of known performance-degrading effects, including hydrodynamic instabilities, impurity mix, fuel energy losses, and laser-plasma interactions, with notable exceptions clearly delineated. In the absence of α heating, our scaling paths exhibit neutron yield per-unit-length scaling as $\tilde{Y}$∝[I$3\atop{max}$,I${4.14}\atop{max}$] and ignition parameter scaling as χ∝[I max ,I${2.14}\atop{max}$]. By considering the specific physics risks unique to each scaling path, we provide a roadmap for future investigations to evaluate different scaling options through detailed numerical studies and scaling-focused experiments on present-day facilities. Overall, these results highlight the potential of MIF as a key component of the national ignition effort.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy

Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system. Approach. Optimized single field, uniform dose treatment plans for 3 × 3 × 3 cm 3 target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic™ EBT3 film. Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT. Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Instrumented Capsule Design to Measure Thermal Conductivity in Miniature UO2 Specimens

Numerous separate effects irradiations of miniature nuclear fuel specimens have been conducted in the High Flux Isotope Reactor (HFIR) under the experimental platform designated as MiniFuel. MiniFuel is a static irradiation capability in which microstructural evolution and fuel performance phenomena are observed during postirradiation examination thereby offering a snapshot of the terminal fuel characteristics. This approach inherently requires fielding an irradiation where the experimental conditions are determined using predictive models and the pertinent outcomes are measured at the end of the test. Static irradiations can provide useful insights to the relationships between fuel performance and the pivotal irradiation conditions, namely temperature and burnup, but the ability to monitor fuel performance in situ would further support fuel development and qualification. To this end, an instrumented experiment design is being developed at Oak Ridge National Laboratory to capture thermal conductivity degradation and fission gas release during HFIR irradiation. These phenomena will be monitored using unique capsule designs that each target a different phenomenon. This paper details the thermal conductivity capsule (TCC) design and its expected performance envelope as determined using computer models. Each TCC will contain a miniature UO2 disc specimen (~0.5 mm thick × 5 mm diameter) sandwiched between metallic slugs with embedded thermocouples. The coupling of in situ temperature measurements, known thermal conductivity of the metallic components, and heat generation rates computed using high-fidelity neutronics models make the thermal conductivity measurement possible. This paper describes the reactor physics and heat transfer models used to predict the capsule’s performance and the methodology for calculating the fuel specimen’s thermal conductivity from the thermocouple measurements.

Gorton, Jacob [ORNL] (ORCID:0000000269806083)↗

Complementary dispersive mirror pair produced in one coating run based on desired non-uniformity

We report a novel one-coating-run method for producing an octave-spanning complementary dispersive mirror (DM) pair. The anti-phase group delay dispersion (GDD) oscillations are realized by two mirrors of the DM pair due to the certain thickness difference. Both mirrors are deposited within a single coating run enabled by the non-uniformity of the ion beam sputtering coating plant, which is obtained by tuning the distance between the source target and coating substrates. Since the DM pair is produced in a single deposition run, the GDD performance is more robust against deposition errors than that of the conventional complementary DM pair, in which two separated coating runs are necessary. Moreover, the new DM pair is compatible for both laser polarizations under the same angle of incidence, which could effectively reduce the difficulties of alignment for their implementation in laser systems than the double angle DM pair. The new DM pair is successfully applied to compress pulses from a Ti: Sapphire laser system down to 4.26 fs in pulse duration.

47 OTHER INSTRUMENTATION↗

Collaboration on SBIR/TTO Phase II Project for Optical QC Device and Collaboration on SBIR/TTO Phase II-b Project for Advanced Quality Inspection Device Development: Cooperative Research and Development CRADA Number CRD-16-00652 (Final Report)

The overall goal of this program is to develop and commercialize a turnkey quality control solution for the entire PEM fuel cell manufacturing process including membrane, gas diffusion layers, catalyst, and assembled systems. This quality control solution is unique to each customer’s specific needs but includes a suite of in-line quality control systems for roll-to-roll manufacturing that can target thin, transparent membrane as well as opaque membrane, catalyst, and GDLs. The Phase II developed the CPNUVV system for thin, transparent membrane that operates using polarized filters to enhance defect resolution and determine thickness. However, PEM material manufacturers want a complete, turnkey solution for all components of the PEM fuel cell. In the Phase IIB, Mainstream will partner with NREL, and transition reflectance technology NREL developed (US Patent 9,234,843) to operate in real-time on a web-line to develop a total solution to PEM quality control. The device will identify and mark defects as well as monitor materials thickness in real-time to improve line efficiency and to reduce waste. The research performed at NREL under this CRADA increases the basis of knowledge about optical inspection methods, how they perform with regards to fuel cell component materials, and how they can be implemented in in-line, real-time configurations to provide quality inspection for roll-to-roll (R2R) manufacturing. Methods explored were found to be sensitive to catalyst loading in electrodes on both membrane and gas diffusion media substrates and to membrane thickness, across a broad range of thickness. The latter capability is novel and now patented and provides a previously unstudied and undemonstrated capability for R2R manufacturing of membranes.

30 DIRECT ENERGY CONVERSION↗