Search NASA⌕ Search

SEARCH · Search NASA

Results for “Validating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

The validation of an invitro colonic motility assay as a biomarker for gastrointestinal adverse drug reactions

Motility-related gastrointestinal adverse drug reactions (GADRs), such as constipation and diarrhea, are some of the most frequently reported adverse events associated with the clinical development of new chemical entities, and for marketed drugs. However, biomarkers capable of detecting such GADRs are lacking. Here, we describe an in vitro assay developed to detect and quantify changes in intestinal motility as a surrogate biomarker for constipation/diarrhea-type GADRs. In vitro recordings of intraluminal pressure were used to monitor the presence of colonic peristaltic motor complexes (CPMCs) in mouse colonic segments. CPMC frequency, contractile and total mechanical activity were assessed. To validate the assay, two experimental protocols were conducted. Initially, five drugs with known gastrointestinal effects were tested to determine optimal parameters describing excitation and inhibition as markers for disturbances in colonic motility. This was followed by a 'blinded' evaluation of nine drugs associated with or without clinically identified constipation/diarrhea-type GADRs. Concentration-response relationships were determined for these drugs and the effects were compared with their maximal free therapeutic plasma concentration in humans. The assay detected stimulatory and inhibitory responses, likely correlating to the occurrence of diarrhea or constipation. Concentration-related effects were identified and potential mechanisms of action were inferred for several drugs. Based on the results from the fourteen drugs assessed, the sensitivity of the assay was calculated at 90%, with a specificity of 75% and predictive capacity of 86%. These results support the potential use of this assay in screening for motility-related GADRs during early discovery phase, safety pharmacology assessment.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Model calibration and validation for OFMSW and sewage sludge co-digestion reactors

Highlights: > Disintegration is the limiting step of the anaerobic co-digestion process. > Disintegration kinetic constant does not depend on the waste particle size. > Disintegration kinetic constant depends only on the waste nature and composition. > The model calibration can be performed on organic waste of any particle size. - Abstract: A mathematical model has recently been proposed by the authors to simulate the biochemical processes that prevail in a co-digestion reactor fed with sewage sludge and the organic fraction of municipal solid waste. This model is based on the Anaerobic Digestion Model no. 1 of the International Water Association, which has been extended to include the co-digestion processes, using surface-based kinetics to model the organic waste disintegration and conversion to carbohydrates, proteins and lipids. When organic waste solids are present in the reactor influent, the disintegration process is the rate-limiting step of the overall co-digestion process. The main advantage of the proposed modeling approach is that the kinetic constant of such a process does not depend on the waste particle size distribution (PSD) and rather depends only on the nature and composition of the waste particles. The model calibration aimed to assess the kinetic constant of the disintegration process can therefore be conducted using organic waste samples of any PSD, and the resulting value will be suitable for all the organic wastes of the same nature as the investigated samples, independently of their PSD. This assumption was proven in this study by biomethane potential experiments that were conducted on organic waste samples with different particle sizes. The results of these experiments were used to calibrate and validate the mathematical model, resulting in a good agreement between the simulated and observed data for any investigated particle size of the solid waste. This study confirms the strength of the proposed model and calibration procedure, which can thus be used to assess the treatment efficiency and predict the methane production of full-scale digesters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Validation of Sandwich ELISA Microarrays with Minimal Assay Interference

Sandwich enzyme-linked immunosorbent assay (ELISA) microarrays are emerging as a strong candidate platform for multiplex biomarker analysis because of the ELISA’s ability to quantitatively measure rare proteins in complex biological fluids. Advantages of this platform are high-throughput potential, assay sensitivity and stringency, and the similarity to the standard ELISA test, which facilitates assay transfer from a research setting to a clinical laboratory. However, a major concern with the multiplexing of ELISAs is maintaining high assay specificity. In this study, we systematically determine the amount of assay interference and noise contributed by individual components of the multiplexed 24-assay system. We find that non-specific reagent cross-reactivity problems are relatively rare. We did identify the presence of contaminant antigens in a “purified antigen”. We tested the validated ELISA microarray chip using paired serum samples that had been collected from four women at a 6-month interval. This analysis demonstrated that protein levels typically vary much more between individuals then within an individual over time, a result which suggests that longitudinal studies may be useful in controlling for biomarker variability across a population. Overall, this research demonstrates the importance of a stringent screening protocol and the value of optimizing the antibody and antigen concentrations when designing chips for ELISA microarrays.

59 BASIC BIOLOGICAL SCIENCES↗

Validation of aerosol extinction and water vapor profiles from routine Atmospheric Radiation Measurement Climate Research Facility measurements

The accuracy with which vertical profiles of aerosol extinction σ ep (λ) can be retrieved from ARM Climate Research Facility (ACRF) routine measurements was assessed using data from two airborne field campaigns, the ARM Aerosol Intensive Operation Period (AIOP, May 2003), and the Aerosol Lidar Validation Experiment (ALIVE, September 2005). This assessment pertains to the aerosol at its ambient concentration and thermodynamic state (i.e. σ ep (λ) either free of or corrected for sampling artifacts) and includes the following ACRF routine methods: Raman Lidar, Micro Pulse Lidar (MPL) and in-situ aerosol profiles (IAP) with a small aircraft. Profiles of aerosol optical depth τp(λ), from which the profiles of σep(λ)are derived through vertical differentiation, were measured by the NASA Ames Airborne Tracking 14-channel Sunphotometer (AATS-14); these data were used as truth in this evaluation. The ACRF IAP σ ep (550 nm) were lower by 16% (during AIOP) and higher by 10% (during ALIVE) when compared to AATS-14. The ACRF MPL σ ep (523 nm) were higher by 24% (AIOP) and 19%-21% (ALIVE) compared to AATS-14 but the correlation improved significantly during ALIVE. In the AIOP a second MPL operated by NASA showed a smaller positive bias (13%) with respect to AATS-14. The ACRF Raman Lidar σ ep (355 nm) were higher by 54% (AIOP) and higher by 6% (ALIVE) compared to AATS-14. The large bias in AIOP stemmed from a gradual loss of the sensitivity of the Raman Lidar starting about the end of 2001 going unnoticed until after AIOP. A major refurbishment and upgrade of the instrument and improvements to a data-processing algorithm led to the significant improvement and very small bias in ALIVE. Finally we find that during ALIVE the Raman Lidar water vapor densities ρw are higher by 8% when compared to AATS-14, whereas comparisons between AATS-14 and in-situ measured ρw aboard two different aircraft showed small negative biases (0 to -3%).

47 OTHER INSTRUMENTATION↗

Validation of x-ray microfocus computed tomography as an imaging tool for porous structures

X-ray microfocus computed tomography (micro-CT) is recently put forward to qualitatively and quantitatively characterize the internal structure of porous materials. However, it is known that artifacts such as the partial volume effect are inherently present in micro-CT images, thus resulting in a visualization error with respect to reality. This study proposes a validation protocol that in the future can be used to quantify this error for porous structures in general by matching micro-CT tomograms to microscopic sections. One of the innovations of the protocol is the opportunity to reconstruct an interpolated micro-CT image under the same angle as the physical cutting angle of the microscopic sections. Also, a novel thresholding method is developed based on matching micro-CT and microscopic images. In this study, titanium porous structures are assessed as proof of principle. It is concluded for these structures that micro-CT visualizes 89% of the total amount of voxels (solid and pore) correctly. However, 8% represents an overestimation of the real structure and 3% are real structural features not visualized by micro-CT. When exclusively focusing on the solid fraction in both the micro-CT and microscopic images, only an overestimation of about 5% is found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-launched flyer plate and confined laser ablation for shock wave loading: Validation and applications

We present validation and some applications of two laser-driven shock wave loading techniques: laser-launched flyer plate and confined laser ablation. We characterize the flyer plate during flight and the dynamically loaded target with temporally and spatially resolved diagnostics. With transient imaging displacement interferometry, we demonstrate that the planarity (bow and tilt) of the loading induced by a spatially shaped laser pulse is within 2-7 mrad (with an average of 4{+-}1 mrad), similar to that in conventional techniques including gas gun loading. Plasma heating of target is negligible, in particular, when a plasma shield is adopted. For flyer plate loading, supported shock waves can be achieved. Temporal shaping of the drive pulse in confined laser ablation allows for flexible loading, e.g., quasi-isentropic, Taylor-wave, and off-Hugoniot loading. These techniques can be utilized to investigate such dynamic responses of materials as Hugoniot elastic limit, plasticity, spall, shock roughness, equation of state, phase transition, and metallurgical characteristics of shock-recovered samples.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation and performance of the LHC cryogenic system through commissioning of the first sector

The cryogenic system [1] for the Large Hadron Collider accelerator is presently in its final phase of commissioning at nominal operating conditions. The refrigeration capacity for the LHC is produced using eight large cryogenic plants and eight 1.8 K refrigeration units installed on five cryogenic islands. Machine cryogenic equipment is installed in a 26.7-km circumference ring deep underground tunnel and are maintained at their nominal operating conditions via a distribution system consisting of transfer lines, cold interconnection boxes at each cryogenic island and a cryogenic distribution line. The functional analysis of the whole system during all operating conditions was established and validated during the first sector commissioning in order to maximize the system availability. Analysis, operating modes, main failure scenarios, results and performance of the cryogenic system are presented.

43 PARTICLE ACCELERATORS↗

Application of the Neo-Deterministic Seismic Microzonation Procedure in Bulgaria and Validation of the Seismic Input Against Eurocode 8

The earthquake record and the Code for design and construction in seismic regions in Bulgaria have shown that the territory of the Republic of Bulgaria is exposed to a high seismic risk due to local shallow and regional strong intermediate-depth seismic sources. The available strong motion database is quite limited, and therefore not representative at all of the real hazard. The application of the neo-deterministic seismic hazard assessment procedure for two main Bulgarian cities has been capable to supply a significant database of synthetic strong motions for the target sites, applicable for earthquake engineering purposes. The main advantage of the applied deterministic procedure is the possibility to take simultaneously and correctly into consideration the contribution to the earthquake ground motion at the target sites of the seismic source and of the seismic wave propagation in the crossed media. We discuss in this study the result of some recent applications of the neo-deterministic seismic microzonation procedure to the cities of Sofia and Russe. The validation of the theoretically modeled seismic input against Eurocode 8 and the few available records at these sites is discussed.

58 GEOSCIENCES↗

In Vitro Validation of a Sector-Switching HIFU Device for Accelerated Treatment

A sector-switching method that increases the HIFU sequence duty-cycle and reduces the equivalent treatment time was tested in vitro. The MR-compatible HIFU device used consisted of 2 symmetric sectors arranged on a truncated spherical cap (focus = 45 mm, long diameter = 57.5 mm, short diameter = 35 mm). A MR-compatible, 2D positioning system provided 0.5 mm accuracy. Two sonication sequences were considered, each with the same pattern for the focal point trajectory and with identical on-state power. First, both sectors radiated simultaneously, with a power duty cycle of 60%. Second, the sectors radiated separately with balanced temporally-interleaved sonication and a power duty cycle of 87.5%. Numerical simulations were performed to predict the shape of the lesion for a given set of sequence parameters, according to a theoretical model. Fast MR thermometry (voxel size: 0.85x0.85x4.25 mm3; temporal resolution: 2 sec) was performed in two orthogonal planes (sagittal and transverse) while the 2D sonication pattern was contained in the coronal plane. Fresh samples of degassed porcine liver were used, and the macroscopic lesions were measured after HIFU. The 14400 s equivalent thermal dose isolevel was compared respectively for the two sonication sequences, both with numerical simulations and experimental MR data. No susceptibility or RF artifacts could be detected on MR data. The lesion's size ratio between reference versus the sector-switched sequence was 1.12 from simulations and 1.25 ({+-}3.2%) from MRI derived TD. Switching the device sectors reduced the treatment time by 20% while the shape and size of the lesions were maintained. In vivo studies are required for pre-clinical validation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of the paraxial beam-tracing method in critical cases

Paraxial Wentzel-Kramers-Brillouin (WKB) (beam-tracing) solutions of a scalar wave equation are compared to the exact solutions for the two important cases of reflection from a plasma with linearly increasing density and of oblique propagation in the presence of an absorbing half plane. In these situations, the beam-tracing technique is close to its limits of validity, yet these conditions are often met in practical applications. More specifically, the first case is relevant to reflectometry diagnostics, whereas the second case models the absorption of electron-cyclotron beams obliquely launched onto the resonance layer, as envisaged, for instance, for the ITER upper launcher [M. A. Henderson et al., Nucl. Fusion 48, 054013 (2008)]. In both cases, the beam-tracing approach is found to reproduce well the exact behavior of the wave for experimentally relevant parameters, confirming the robustness of WKB-based techniques close to or even beyond their range of applicability. For the latter case, moreover, the analysis presented here allows an evaluation of the reflection of part of the beam by the steep gradients of the absorption coefficient at the resonance layer, our results yielding an upper bound on the amount of reflected power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A verification and validation effort for high explosives at Los Alamos National Lab (u)

We have started a project to verify and validate ASC codes used to simulate detonation waves in high explosives. Since there are no non-trivial analytic solutions, we are going to compare simulated results with experimental data that cover a wide range of explosive phenomena. The intent is to compare both different codes and different high explosives (HE) models. The first step is to test the products equation of state used for the HE models, For this purpose, the cylinder test, flyer plate and plate-push experiments are being used. These experiments sample different regimes in thermodynamic phase space: the CJ isentrope for the cylinder tests, the isentrope behind an overdriven detonation wave for the flyer plate experiment, and expansion following a reflected CJ detonation for the plate-push experiment, which is sensitive to the Gruneisen coefficient. The results of our findings for PBX 9501 are presented here.

36 MATERIALS SCIENCE↗

Experimental Validation of Simulations Using Full-field Measurement Techniques

The calibration by reference materials of dynamic full-field measurement systems is discussed together with their use to validate numerical simulations of structural mechanics. The discussion addresses three challenges that are faced in these processes, i.e. how to calibrate a measuring instrument that (i) provides full-field data, and (ii) is dynamic; (iii) how to compare data from simulation and experimentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pole approximation validation in the study of the {sup 6}Li(d,{alpha}){sup 4}He reaction

The Trojan Horse Method (THM) was applied to the {sup 3}He+{sup 6}Li interaction in order to investigate the quasi-free {sup 6}Li(d,{alpha}){sup 4}He reaction. The experiment was performed at 17 MeV at the Cyclotron Institute of the Czech Academy of Science. The extracted {sup 6}Li(d,{alpha}){sup 4}He quasi-free cross-section was compared with the behavior of direct data. A good agreement between data sets shows up throughout the energy range investigated, providing a very important validity test of the pole approximation for the THM above the Coulomb barrier.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of a Custom-made Software for DQE Assessment in Mammography Digital Detectors

This works presents the validation of a custom-made software, designed and developed in Matlab, intended for routine evaluation of detective quantum efficiency DQE, according to algorithms described in the IEC 62220-1-2 standard. DQE, normalized noise power spectrum NNPS and pre-sampling modulation transfer function MTF were calculated from RAW images from a GE Senographe DS (FineView disabled) and a Siemens Novation system. Calculated MTF is in close agreement with results obtained with alternative codes: MTF lowbar tool (Maidment), ImageJ plug-in (Perez-Ponce) and MIQuaELa (Ayala). Overall agreement better than {approx_equal}90% was found in MTF; the largest differences were observed at frequencies close to the Nyquist limit. For the measurement of NNPS and DQE, agreement is similar to that obtained in the MTF. These results suggest that the developed software can be used with confidence for image quality assessment.

97 MATHEMATICS AND COMPUTING↗

Integrating Materials, Manufacturing, Design and Validation for Sustainability in Future Transport Systems

The predictive methods currently used for material specification, component design and the development of manufacturing processes, need to evolve beyond the current 'metal centric' state of the art, if advanced composites are to realise their potential in delivering sustainable transport solutions. There are however, significant technical challenges associated with this process. Deteriorating environmental, political, economic and social conditions across the globe have resulted in unprecedented pressures to improve the operational efficiency of the manufacturing sector generally and to change perceptions regarding the environmental credentials of transport systems in particular. There is a need to apply new technologies and develop new capabilities to ensure commercial sustainability in the face of twenty first century economic and climatic conditions as well as transport market demands. A major technology gap exists between design, analysis and manufacturing processes in both the OEMs, and the smaller companies that make up the SME based supply chain. As regulatory requirements align with environmental needs, manufacturers are increasingly responsible for the broader lifecycle aspects of vehicle performance. These include not only manufacture and supply but disposal and re-use or re-cycling. In order to make advances in the reduction of emissions coupled with improved economic efficiency through the provision of advanced lightweight vehicles, four key challenges are identified as follows: Material systems, Manufacturing systems, Integrated design methods using digital manufacturing tools and Validation systems. This paper presents a project which has been designed to address these four key issues, using at its core, a digital framework for the creation and management of key parameters related to the lifecycle performance of thermoplastic composite parts and structures. It aims to provide capability for the proposition, definition, evaluation and demonstration of advanced lightweight structures for new generation vehicles in the context of whole life performance parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of the Electrical Properties of the ITER ICRF Antenna using Reduced-Scale Mock-Ups

Experimental measurements on reduced-scale mock-ups allow validating the electrical properties and RF numerical optimization of the ITER ICRF antenna. Frequency response in the different regions of the antenna is described and key parameters for performance improvement are given. Coupling is improved by acting on the front-face geometry (strap width, antenna box depth and vertical septa recess). The 4-port junction acts as a frequency filter and together with the service stub performs pre-matching in the whole frequency band. Influence of the Faraday screen on coupling is limited. The effect of voltage limitation on the maximum total radiated power is given. The importance of a good decoupling network and of grounding is emphasized. Finally the control of the antenna wave spectrum is performed by implementing feedback controlled load-resilient matching and decoupling options and control algorithms are tested.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Use of a multichannel collimator for structural investigation of low-Z dense liquids in a diamond anvil cell: Validation on fluid H{sub 2} up to 5 GPa

We report the first application of a multichannel collimator (MCC) to perform quantitative structure factor measurements of dense low-Z fluids in a diamond anvil cell (DAC) using synchrotron x-ray diffraction. The MCC design, initially developed for the Paris-Edinburgh large volume press geometry, has been modified for use with diamond anvil cells. A good selectivity of the diffracted signal of the dense fluid sample is obtained due to a large rejection of the Compton diffusion from the diamond anvils. The signal to background ratio is significantly improved. We modify previously developed analytical techniques for quantitative measurement of the structure factor of fluids in DACs [J. H. Eggert, G. Weck, P. Loubeyre, and M. Mezouar, Phys. Rev. B 65, 174105 (2002)] to account for the contribution of the MCC. We present experimental results on liquids argon and hydrogen at 296 K to validate our method and test its limits, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of elastic constants of monoclinic nickel-titanium and validation of first principles calculations

Polycrystalline, monoclinic nickel-titanium specimens were subjected to tensile and compressive deformations while neutron diffraction spectra were recorded in situ. Using these data, orientation-specific and macroscopic Young's moduli are determined from analysis of linear-elastic deformation exhibited by 13 unique orientations of monoclinic lattices and their relationships to each macroscopic stress and strain. Five of 13 elastic compliance constants are also identified: s{sub 11} = 1.15, s{sub 15} = -1.10, s{sub 22} = 1.34, s{sub 33} = 1.06, s{sub 35} = -1.54, all Multiplication-Sign 10{sup -2} GPa{sup -1}. Through these results, recent atomistic calculations of monoclinic nickel-titanium elastic constants are validated.

36 MATERIALS SCIENCE↗