Search NASA⌕ Search

SEARCH · Search NASA

Results for “Virtualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Spin Structure of the Deuteron--New Results from CLAS

Double spin asymmetries for the proton and the deuteron have been measured in the EG1B experiment using the CLAS detector at Jefferson Lab. Longitudinally polarized electrons at energies 1.6, 2.5, 4.2 and 5.75 GeV were scattered from longitudinally polarized NH{sub 3} and ND{sub 3} targets. The double spin asymmetry A{sub ||} for the proton and the deuteron has been extracted from these data as a function of W and Q{sup 2} with unprecedented precision. The virtual photon asymmetry A{sub 1} and the spin structure function g{sub 1} can be calculated from these measurements by using parametrization to the world data for the virtual photon asymmetry A{sub 2} and the unpolarized structure functions F{sub 1} and R. The large kinematic coverage of the experiment (0.05 GeV{sup 2}<Q{sup 2}<0.5 GeV{sup 2} and 1.08 GeV<W<3.0 GeV) helps us to better understand the spin structure of the nucleon, especially in the transition region between hadronic and quark-gluon degrees of freedom. The results on A{sub 1}, g{sub 1} and {gamma}{sub 1} using the entire data set for the deuteron data are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transition nucleon resonance electrocouplings from CLAS data on {pi}{sup +}{pi}{sup -}p electroproduction off protons

Electrocouplings of excited proton states with masses less than 1.8 GeV were determined for the first time from the CLAS data on {pi}{sup +}{pi}{sup -}p electroproduction at photon virtualities Q{sup 2}<1.5 GeV{sup 2}. Electrocouplings were obtained from a combined fit of all available observables within the framework of a phenomenological reaction model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-power microwave amplifier based on overcritical relativistic electron beam without external magnetic field

The high-power scheme for the amplification of powerful microwave signals based on the overcritical electron beam with a virtual cathode (virtual cathode amplifier) has been proposed and investigated numerically. General output characteristics of the virtual cathode amplifier including the dependencies of the power gain on the input signal frequency and amplitude have been obtained and analyzed. The possibility of the geometrical working frequency tuning over the range about 8%–10% has been shown. The obtained results demonstrate that the proposed virtual cathode amplifier scheme may be considered as the perspective high-power microwave amplifier with gain up to 18 dB, and with the following important advantages: the absence of external magnetic field, the simplicity of construction, the possibility of geometrical frequency tuning, and the amplification of relatively powerful microwave signals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cloud services for the Fermilab scientific stakeholders

As part of the Fermilab/KISTI cooperative research project, Fermilab has successfully run an experimental simulation workflow at scale on a federation of Amazon Web Services (AWS), FermiCloud, and local FermiGrid resources. We used the CernVM-FS (CVMFS) file system to deliver the application software. We established Squid caching servers in AWS as well, using the Shoal system to let each individual virtual machine find the closest squid server. We also developed an automatic virtual machine conversion system so that we could transition virtual machines made on FermiCloud to Amazon Web Services. We used this system to successfully run a cosmic ray simulation of the NOvA detector at Fermilab, making use of both AWS spot pricing and network bandwidth discounts to minimize the cost. On FermiCloud we also were able to run the workflow at the scale of 1000 virtual machines, using a private network routable inside of Fermilab. As a result, we present in detail the technological improvements that were used to make this work a reality.

97 MATHEMATICS AND COMPUTING↗

Inclusive jet and hadron suppression in a multistage approach

We present a new study of jet interactions in the quark-gluon plasma created in high-energy heavy-ion collisions, using a multistage event generator within the jetscape framework. We focus on medium-induced modifications in the rate of inclusive jets and high transverse momentum (high-p T ) hadrons. Scattering-induced jet energy loss is calculated in two stages: a high virtuality stage based on the matter model, in which scattering of highly virtual partons modifies the vacuum radiation pattern, and a second stage at lower jet virtuality based on the LBT model, in which leading partons gain and lose virtuality by scattering and radiation. Coherence effects that reduce the medium-induced emission rate in the matter phase are also included. The TRENTO model is used for initial conditions, and the (2 + 1)dimensional VISHNU model is used for viscous hydrodynamic evolution. Jet interactions with the medium are modeled via 2-to-2 scattering with Debye screened potentials, in which the recoiling partons are tracked, hadronized, and included in the jet clustering. Holes left in the medium are also tracked and subtracted to conserve transverse momentum. Calculations of the nuclear modification factor (R AA ) for inclusive jets and high-p T hadrons are compared to experimental measurements at the BNL Relativistic Heavy Ion Collider (RHIC) and the CERN Large Hadron Collider (LHC). Within this framework, we find that with one extra parameter which codifies the transition between stages of jet modification—along with the typical parameters such as the coupling in the medium, the start and stop criteria, etc.—we can describe these data at all energies for central and semicentral collisions without a rescaling of the jet transport coefficient q.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiscale evolution of charmed particles in a nuclear medium

Parton energy-momentum exchange with the quark gluon plasma (QGP) is a multiscale problem. In this work, we calculate the interaction of charm quarks with the QGP within the higher twist formalism at high virtuality and high energy using the Modular All Twist Transverse-scattering Elastic-drag and Radiation (MATTER) model, while the low-virtuality and high-energy portion is treated via a linearized Boltzmann transport formalism. Coherence effect that reduces the medium-induced emission rate in the MATTER model is also taken into account through a virtuality-dependent qˆ, leaving the simultaneous dependence of qˆ on heavy quark mass and virtuality for future studies. The interplay between these two formalisms is studied phenomenologically and used to produce a first description of the D-meson and charged hadron nuclear modification factor R AA across multiple centralities. As a result, all calculations were carried out utilizing the Jet Energy-loss Tomography with a Statistically and Computationally Advanced Program Envelope framework.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cross sections and Rosenbluth separations in {sup 1}H(e,e{sup '}K{sup +})LAMBDA up to Q{sup 2}=2.35 GeV{sup 2}

The kaon electroproduction reaction {sup 1}H(e,e{sup '}K{sup +})LAMBDA was studied as a function of the virtual-photon four-momentum, Q{sup 2}, total energy, W, and momentum transfer, t, for different values of the virtual-photon polarization parameter. Data were taken at electron beam energies ranging from 3.40 to 5.75 GeV. The center of mass cross section was determined for twenty-one kinematics corresponding to Q{sup 2} of 1.90 and 2.35 GeV{sup 2}, and the longitudinal, sigma{sub L}, and transverse, sigma{sub T}, cross sections were separated using the Rosenbluth technique at fixed W and t. The separated cross sections reveal a flat energy dependence at forward kaon angles not satisfactorily described by existing electroproduction models. Influence of the kaon pole on the cross sections was investigated by adopting an off-shell form factor in the Regge model, which better describes the observed energy dependence of sigma{sub T} and sigma{sub L}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Final-state interactions in semi-inclusive deep inelastic scattering off the deuteron

Semi-inclusive deep inelastic scattering off the deuteron with production of a slow nucleon in recoil kinematics is studied in the virtual nucleon approximation, in which the final-state interaction (FSI) is calculated within generalized eikonal approximation. The cross section is derived in a factorized approach, with a factor describing the virtual photon interaction with the off-shell nucleon and a distorted spectral function accounting for the final-state interactions. One of the main goals of the study is to understand how much the general features of the diffractive high-energy soft rescattering accounts for the observed features of FSI in deep inelastic scattering (DIS). Comparison with the Jefferson Lab data shows good agreement in the covered range of kinematics. Most importantly, our calculation correctly reproduces the rise of the FSI in the forward direction of the slow nucleon production angle. By fitting our calculation to the data we extracted the W and Q{sup 2} dependencies of the total cross section and slope factor of the interaction of DIS products, X, off the spectator nucleon. This analysis shows the XN-scattering cross section rising with W and decreasing with an increase of Q{sup 2}. Finally, our analysis points at a largely suppressed off-shell part of the rescattering amplitude.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Anomalous form factor of the neutral pion in an extended AdS/QCD model with Chern-Simons term

We propose an extension of the hard-wall AdS/QCD model by including the Chern-Simons term required to reproduce the chiral anomaly of QCD. In the framework of this holographic model, we study the vertex function F{sub {pi}}{sub {gamma}}{sub *{gamma}}{sub *}(Q{sub 1}{sup 2},Q{sub 2}{sup 2}) which accumulates information about the coupling of the pion to two (in general virtual) photons. We calculate the slope of the form factor with one real and one slightly virtual photon and show that it is close to experimental findings. We analyze the formal limit of large virtualities and establish that predictions of the holographic model analytically (including nontrivial dependence on the ratio of photon virtualities) coincide with those of perturbative QCD calculated for the asymptotic form of the pion distribution amplitude. We also investigate the generalized vector-meson-dominance structure of F{sub {pi}}{sub {gamma}}{sub *{gamma}}{sub *}(Q{sub 1}{sup 2},Q{sub 2}{sup 2}) in the extended AdS/QCD model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vacuum energy and the spacetime index of refraction: A new synthesis

In 1+3 (threading) formulation of general relativity spacetime behaves analogous to a medium with a specific index of refraction with respect to the light propagation. Accepting the reality of zero-point energy, through the equivalence principle, we elevate this analogy to the case of virtual photon propagation in a quantum vacuum in a curved background spacetime. Employing this new idea (conjecture) one could examine the response of vacuum energy to the presence of a weak stationary gravitational field in its different quantum field theoretic manifestations such as Casimir effect and Lamb shift. As an evidence in favor of the proposed conjecture, employing quantum field theory in curved spacetime, we explicitly calculate the effect of a weak static gravitational field on virtual massless scalar particles in a Casimir apparatus. It is shown that, as expected from the proposed conjecture, both the frequency and renormalized energy of the virtual scalar field are affected by the gravitational field through its index of refraction. Generalizations to weak stationary spacetimes and virtual photons are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identification of Program Signatures from Cloud Computing System Telemetry Data

Malicious cloud computing activity can take many forms, including running unauthorized programs in a virtual environment. Detection of these malicious activities while preserving the privacy of the user is an important research challenge. Prior work has shown the potential viability of using cloud service billing metrics as a mechanism for proxy identification of malicious programs. Previously this novel detection method has been evaluated in a synthetic and isolated computational environment. In this paper we demonstrate the ability of billing metrics to identify programs, in an active cloud computing environment, including multiple virtual machines running on the same hypervisor. The open source cloud computing platform OpenStack, is used for private cloud management at Pacific Northwest National Laboratory. OpenStack provides a billing tool (Ceilometer) to collect system telemetry measurements. We identify four different programs running on four virtual machines under the same cloud user account. Programs were identified with up to 95% accuracy. This accuracy is dependent on the distinctiveness of telemetry measurements for the specific programs we tested. Future work will examine the scalability of this approach for a larger selection of programs to better understand the uniqueness needed to identify a program. Additionally, future work should address the separation of signatures when multiple programs are running on the same virtual machine.

Nichols, Nicole M.↗

Multi-Time Scale Coordinated Control and Scheduling of Inverter-Based TCLs With Variable Wind Generation

To address microgrid tie flow errors caused by wind generation variability, here we propose and develop a multi-time scale coordinated control and scheduling strategy for inverter-based thermostatically controlled loads (TCLs). First, in hour-time scale, inverter-based TCLs with adjusting temperature set-point are modeled as virtual generators to compensate tie flow deviations in the day-ahead plan. Next, in minute-time scale, virtual batteries representing operating behaviors of inverter-based TCLs with frequency control are scheduled determined by the control of virtual generators in hour-time scale. The virtual batteries are scheduled to smooth out tie flow errors corresponding to day-ahead plan and hour-time scale schedules. The multi-time scale control methods are coordinated to employ the response potential of inverter-based TCLs and response curve-based methods are proposed to control inverter-based TCLs considering the customer privacy. The multi-time scale stochastic schedules which are based on response curves of inverter-based TCLs are coordinated to accommodate wind generation variability. Simulation results demonstrate that the microgrid tie flow errors are effectively mitigated by the proposed multi-time scale coordinated control and scheduling of inverter-based TCLs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ASDFL: An adaptive super‐pixel discriminative feature‐selective learning for vehicle matching

Abstract There are a large number of cameras in modern transportation system that capture numerous vehicle images continuously. Therefore, automatic analysis of these vehicle images is helpful for traffic flow management, criminal investigations and vehicle inspections. Vehicle matching, which aims to determine whether two input images depict an identical vehicle, is one of the core tasks in vehicle analysis. Recent relevant studies have focused on local feature extraction instead of global extraction, since local details can provide crucial cues to distinguish between cars. However, these methods do not select local features; that is, they do not assign weights to local features. Therefore, in this research, we systematically study the vehicle matching task, and present a novel annotation‐free local‐based deep learning method called Adaptive super‐pixel discriminative feature‐selective learning (ASDFL) to address this issue. In ASDFL, vehicle images are segmented into clusters of super‐pixels of similar size by considering the location and colour similarities of pixels without using any component‐level annotation. These super‐pixels are deemed to be the virtual components of vehicles. Moreover, a convolutional neural network is used to extract the deep features of these virtual components. Thereafter, an instance‐specific mask generation module driven by the extracted global features is enhanced to produce a mask to select the most distinctive virtual components of each vehicle image pair in the feature space. Finally, the vehicle matching task is accomplished by classifying the selected virtual component features of each imaged vehicle pair. Extensive experiments on two popular vehicle identification benchmarks demonstrate that our method is 1.57% and 0.8% more accurate than the previous baselines in a vehicle matching task on the VeRi and VehicleID datasets, respectively, which demonstrates the effectiveness of our method.

Qin, Rong↗

The impacts of dental filling materials on RapidArc treatment planning and dose delivery: Challenges and solution

Purpose: The presence of high-density material in the oral cavity creates dose perturbation in both downstream and upstream directions at the surfaces of dental filling materials (DFM). In this study, the authors have investigated the effect of DFM on head and neck RapidArc treatment plans and delivery. Solutions are proposed to address (1) the issue of downstream dose perturbation, which might cause target under dosage, and (2) to reduce the upstream dose from DFM which may be the primary source of mucositis. In addition, an investigation of the clinical role of a custom-made plastic dental mold/gutter (PDM) in sparing the oral mucosa and tongue reaction is outlined.Methods: The influence of the dental filling artifacts on dose distribution was investigated using a geometrically well-defined head and neck intensity modulated radiation therapy (IMRT) verification phantom (PTW, Freiberg, Germany) with DFM inserts called amalgam, which contained 50% mercury, 25% silver, 14% tin, 8% copper, and 3% other trace metals. Three RapidArc plans were generated in the Varian Eclipse System to treat the oral cavity using the same computer tomography (CT) dataset, including (1) a raw CT image, (2) a streaking artifacts region, which was replaced with a mask of 10 HU, and (3) a 2 cm-thick 6000 HU virtual filter [a volume created in treatment planning system to compensate for beam attenuation, where the thickness of this virtual filter is based on the measured percent depth dose (PDD) data and Eclipse calculation]. The dose delivery for the three plans was verified using Gafchromic-EBT2 film measurements. The custom-made PDM technique to reduce backscatter dose was clinically tested on four head and neck cancer patients (T3, N1, M0) with DFM, two patients with PDM and the other two patients without PDM. The thickness calculation of the PDM toward the mucosa and tongue was purely based on the measured upstream dose. Patients’ with oral mucosal reaction was clinically examined initially and weekly during the course of radiotherapy.Results: For a RapidArc treatment technique, the backscatter dose from the DFM insert was measured to be 9.25 ± 2.17 in the IMRT-verification-phantom. The measured backscatter upstream dose from DFM for a single-field was 22% higher than without the DFM, whereas the downstream dose was lower by 14%. The values of homogeneity index for the plans with and without the application of mask were 0.09 and 0.14, respectively. The calculated mean treatment planning volume (PTV) dose differed from the delivered dose by 13% and was reduced to 2% when using the mask and virtual filter together. A grade 3 mucosa reaction was observed in the control group after 22–24 fractions (44–48 Gy). In contrast, no grade 3 mucositis was observed in the patients wearing the PDM after 25–26 fractions (50–52 Gy).Conclusions: The backscatter from the DFM for a single, parallel-opposed fields, and RapidArc treatment technique was found significant. The application of mask in replacing streaking artifacts can be useful in improving dose homogeneity in the PTV. The use of a virtual filter around the teeth during the planning phase reduces the target underdosage issue in the phantom. Furthermore, a reduction in mucositis is observed in the head and neck patients with the use of PDM.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-D-18C-04: The Feasibility of Quantifying MRI Contrast Agent in Pulsatile Flowing Blood Using DCE-MRI

Purpose: To assess the feasibility of accurately quantifying the concentration of MRI contrast agent (CA) in pulsatile flowing blood by measuring its T{sub 1}, as is common for the purposes of obtaining a patientspecific arterial input function (AIF). Dynamic contrast enhanced (DCE) - MRI and pharmacokinetic (PK) modelling is widely used to produce measures of vascular function but accurate measurement of the AIF undermines their accuracy. A proposed solution is to measure the T{sub 1} of blood in a large vessel using the Fram double flip angle method during the passage of a bolus of CA. This work expands on previous work by assessing pulsatile flow and the changes in T{sub 1} seen with a CA bolus. Methods: A phantom was developed which used a physiological pump to pass fluid of a known T{sub 1} (812ms) through the centre of a head coil of a clinical 1.5T MRI scanner. Measurements were made using high temporal resolution sequences suitable for DCE-MRI and were used to validate a virtual phantom that simulated the expected errors due to pulsatile flow and bolus of CA concentration changes typically found in patients. Results: : Measured and virtual results showed similar trends, although there were differences that may be attributed to the virtual phantom not accurately simulating the spin history of the fluid before entering the imaging volume. The relationship between T{sub 1} measurement and flow speed was non-linear. T{sub 1} measurement is compromised by new spins flowing into the imaging volume, not being subject to enough excitations to have reached steady-state. The virtual phantom demonstrated a range of recorded T{sub 1} for various simulated T{sub 1} / flow rates. Conclusion: T{sub 1} measurement of flowing blood using standard DCE-MRI sequences is very challenging. Measurement error is non-linear with relation to instantaneous flow speed. Optimising sequence parameters and lowering baseline T{sub 1} of blood should be considered.

60 APPLIED LIFE SCIENCES↗

A generic high-dose rate {sup 192}Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) {sup 192}Ir source and a virtual water phantom were designed, which can be imported into a TPS. Methods: A hypothetical, generic HDR {sup 192}Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic {sup 192}Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra{sup ®} Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS{sup TM}]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201){sup 3} voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR {sup 192}Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by different investigators. MC results were then compared against dose calculated using TG-43 and MBDCA methods. Results: TG-43 and PSS datasets were generated for the generic source, the PSS data for use with the ACE algorithm. The dose-rate constant values obtained from seven MC simulations, performed independently using different codes, were in excellent agreement, yielding an average of 1.1109 ± 0.0004 cGy/(h U) (k = 1, Type A uncertainty). MC calculated dose-rate distributions for the two plans were also found to be in excellent agreement, with differences within type A uncertainties. Differences between commercial MBDCA and MC results were test, position, and calculation parameter dependent. On average, however, these differences were within 1% for ACUROS and 2% for ACE at clinically relevant distances. Conclusions: A hypothetical, generic HDR {sup 192}Ir source was designed and implemented in two commercially available TPSs employing different MBDCAs. Reference dose distributions for this source were benchmarked and used for the evaluation of MBDCA calculations employing a virtual, cubic water phantom in the form of a CT DICOM image series. The implementation of a generic source of identical design in all TPSs using MBDCAs is an important step toward supporting univocal commissioning procedures and direct comparisons between TPSs.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-152: Building An Ultrafast, Earthquake Proof Treatment Planning System

Purpose: Situated 20 miles from 5 major fault lines in California’s Bay Area, Stanford Universityhas a critical need for IT infrastructure planning to handle the high probability devastating earthquakes. Recently, a multi-million dollar project has been underway to overhaul Stanford’s radiation oncology information systems, maximizing planning system performance and providing true disaster recovery abilities. An overview of the project will be given with particular focus on lessons learned throughout the build. Methods: In this implementation, two isolated external datacenters provide geographical redundancy to Stanford’s main campus datacenter. Real-time mirroring is made of all data stored to our serial attached network (SAN) storage. In each datacenter, hardware/software virtualization was heavily implemented to maximize server efficiency and provide a robust mechanism to seamlessly migrate users in the event of an earthquake. System performance is routinely assessed through the use of virtualized data robots, able to log in to the system at scheduled times, perform routine planning tasks and report timing results to a performance dashboard. A substantial dose calculation framework (608 CPU cores) has been constructed as part of the implementation. Results: Migration to a virtualized server environment with a high performance SAN has resulted in up to a 45% speed up of common treatment planning tasks. Switching to a 608 core DCF has resulted in a 280% speed increase in dose calculations. Server tuning was found to further improved read/write performance by 20%. Disaster recovery tests are carried out quarterly and, although successful, remain time consuming to perform and verify functionality. Conclusion: Achieving true disaster recovery capabilities is possible through server virtualization, support from skilled IT staff and leadership. Substantial performance improvements are also achievable through careful tuning of server resources and disk read/write operations. Developing a streamlined method to comprehensively test failover is a key requirement to the system’s success.

60 APPLIED LIFE SCIENCES↗

Lung motion estimation using dynamic point shifting: An innovative model based on a robust point matching algorithm

Purpose: Image-guided radiotherapy is an advanced 4D radiotherapy technique that has been developed in recent years. However, respiratory motion causes significant uncertainties in image-guided radiotherapy procedures. To address these issues, an innovative lung motion estimation model based on a robust point matching is proposed in this paper. Methods: An innovative robust point matching algorithm using dynamic point shifting is proposed to estimate patient-specific lung motion during free breathing from 4D computed tomography data. The correspondence of the landmark points is determined from the Euclidean distance between the landmark points and the similarity between the local images that are centered at points at the same time. To ensure that the points in the source image correspond to the points in the target image during other phases, the virtual target points are first created and shifted based on the similarity between the local image centered at the source point and the local image centered at the virtual target point. Second, the target points are shifted by the constrained inverse function mapping the target points to the virtual target points. The source point set and shifted target point set are used to estimate the transformation function between the source image and target image. Results: The performances of the authors’ method are evaluated on two publicly available DIR-lab and POPI-model lung datasets. For computing target registration errors on 750 landmark points in six phases of the DIR-lab dataset and 37 landmark points in ten phases of the POPI-model dataset, the mean and standard deviation by the authors’ method are 1.11 and 1.11 mm, but they are 2.33 and 2.32 mm without considering image intensity, and 1.17 and 1.19 mm with sliding conditions. For the two phases of maximum inhalation and maximum exhalation in the DIR-lab dataset with 300 landmark points of each case, the mean and standard deviation of target registration errors on the 3000 landmark points of ten cases by the authors’ method are 1.21 and 1.04 mm. In the EMPIRE10 lung registration challenge, the authors’ method ranks 24 of 39. According to the index of the maximum shear stretch, the authors’ method is also efficient to describe the discontinuous motion at the lung boundaries. Conclusions: By establishing the correspondence of the landmark points in the source phase and the other target phases combining shape matching and image intensity matching together, the mismatching issue in the robust point matching algorithm is adequately addressed. The target registration errors are statistically reduced by shifting the virtual target points and target points. The authors’ method with consideration of sliding conditions can effectively estimate the discontinuous motion, and the estimated motion is natural. The primary limitation of the proposed method is that the temporal constraints of the trajectories of voxels are not introduced into the motion model. However, the proposed method provides satisfactory motion information, which results in precise tumor coverage by the radiation dose during radiotherapy.

60 APPLIED LIFE SCIENCES↗