Search NASA⌕ Search

SEARCH · Search NASA

Results for “collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Note: Measurement of extreme-short current pulse duration of runaway electron beam in atmospheric pressure air

This note reports the time-amplitude characteristic of the supershort avalanche electron beam with up to 20 ps time resolution. For the first time it is shown that the electron beam downstream of small-diameter diaphragms in atmospheric pressure air has a complex structure which depends on the interelectrode gap width and cathode design. With a spherical cathode and collimator the minimum duration at half maximum of the supershort avalanche electron beam current pulse was shown to be {approx}25 ps. The minimum duration at half maximum of one peak in the pulses with two peaks can reach {approx}25 ps too.

43 PARTICLE ACCELERATORS↗

X-ray induced Sm{sup 3+} to Sm{sup 2+} conversion in fluorophosphate and fluoroaluminate glasses for the monitoring of high-doses in microbeam radiation therapy

Fluorophosphate and fluoroaluminate glasses doped with trivalent samarium were evaluated as sensors of x-ray radiation for microbeam radiation therapy at the Canadian Light Source using the conversion of trivalent Sm{sup 3+} to the divalent form Sm{sup 2+}. Both types of glasses show similar conversion rates and may be used as a linear sensor up to {approx}150 Gy and as a nonlinear sensor up to {approx}2400 Gy, where saturation is reached. Experiments with a multi-slit collimator show high spatial resolution of the conversion pattern; the pattern was acquired by a confocal fluorescence microscopy technique. The effects of previous x-ray exposure may be erased by annealing at temperatures exceeding the glass transition temperature T{sub g} while annealing at T{sub A} < T{sub g} enhances the Sm conversion. This enhancement is explained by a thermally stimulated relaxation of host glass ionic matrix surrounding x-ray induced Sm{sup 2+} ions. In addition, some of the Sm{sup 3+}-doped glasses were codoped with Eu{sup 2+}-ions but the results show that there is no marked improvement in the conversion efficiency by the introduction of Eu{sup 2+}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectra of photons and neutrons generated in a heterogeneous head of a 15 MV LINAC at differents field sizes

Spectra of photons and neutrons were calculated, using the Monte Carlo code MCNP-5 using the e/p/n mode. A heterogeneous model was used to define the linac head where the collimators were modeled to produce five different treatment fields at the isocenter. Photon and neutron spectra were estimated in several points along two directions from the isocenter. The total photon fluence beyond 60 cm behaves according to 1/r{sup 2} rule, while total neutron fluence, beyond 80 cm, can be described by diffusion theory using an infinite plane as a neutron source.

43 PARTICLE ACCELERATORS↗

Powder diffraction from solids in the terapascal regime

A method of obtaining powder diffraction data on dynamically compressed solids has been implemented at the Jupiter and OMEGA laser facilities. Thin powdered samples are sandwiched between diamond plates and ramp compressed in the solid phase using a gradual increase in the drive-laser intensity. The pressure history in the sample is determined by back-propagation of the measured diamond free-surface velocity. A pulse of x rays is produced at the time of peak pressure by laser illumination of a thin Cu or Fe foil and collimated at the sample plane by a pinhole cut in a Ta substrate. The diffracted signal is recorded on x-ray sensitive material, with a typical d-spacing uncertainty of {approx}0.01 A. This diagnostic has been used up to 0.9 TPa (9 Mbar) to verify the solidity, measure the density, constrain the crystal structure, and evaluate the strain-induced texturing of a variety of compressed samples spanning atomic numbers from 6 (carbon) to 82 (lead). Further refinement of the technique will soon enable diffraction measurements in solid samples at pressures exceeding 1 TPa.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coherent femtosecond low-energy single-electron pulses for time-resolved diffraction and imaging: A numerical study

We numerically investigate the properties of coherent femtosecond single electron wave packets photoemitted from nanotips in view of their application in ultrafast electron diffraction and non-destructive imaging with low-energy electrons. For two different geometries, we analyze the temporal and spatial broadening during propagation from the needle emitter to an anode, identifying the experimental parameters and challenges for realizing femtosecond time resolution. The simple tip-anode geometry is most versatile and allows for electron pulses of several ten of femtosecond duration using a very compact experimental design, however, providing very limited control over the electron beam collimation. A more sophisticated geometry comprising a suppressor-extractor electrostatic unit and a lens, similar to typical field emission electron microscope optics, is also investigated, allowing full control over the beam parameters. Using such a design, we find {approx}230 fs pulses feasible in a focused electron beam. The main limitation to achieve sub-hundred femtosecond time resolution is the typical size of such a device, and we suggest the implementation of more compact electron optics for optimal performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The LILIA experiment: Energy selection and post-acceleration of laser generated protons

The LILIA experiment is planned at the SPARCLAB facility of the Frascati INFN laboratories. We have simulated the laser acceleration of protons, the transport and energy selection with collimators and a pulsed solenoid and the post-acceleration with a compact high field linac. For the highest achievable intensity corresponding to a= 30 over 10{sup 8} protons at 30 MeV with a 3% spread are selected, and at least10{sup 7} protons are post-accelerated up to 60 MeV. If a 10 Hz repetition rated can be achieved the delivered dose would be suitable for the treatment of small superficial tumors.

43 PARTICLE ACCELERATORS↗

150 {mu}A 18F{sup -} target and beam port upgrade for the IBA 18/9 cyclotron

A high power ({approx}3 kW) target platform has been developed for the IBA 18/9 cyclotron. New designs for the airlock, collimator and target subsystems have been fabricated and deployed. The primary project goal is reliable commercial production of 18F{sup -} at 150 {mu}A or greater, while secondary goals include improving serviceability and extending service intervals relative to OEM systems. Reliable operation in a production environment has been observed at beam currents up to 140 {mu}A. Challenges include ion source lifetime and localized peaking in the beam intensity distribution.

43 PARTICLE ACCELERATORS↗

Focusing giga-electronvolt heavy ions to micrometers at the Institute of Modern Physics

To study the radiation effect of cosmic heavy ions of low fluxes in electronics and living samples, a focusing heavy ion microbeam facility, for ions with energies of several MeV/u up to 100 MeV/u, was constructed in the Institute of Modern Physics of the Chinese Academy of Sciences. This facility has a vertical design and an experiment platform for both in-vacuum analysis and in-air irradiation. Recently, microbeam of {sup 12}C{sup 6+} with energy of 80.55 MeV/u was successfully achieved at this interdisciplinary microbeam facility with a full beam spot size of 3 {mu}m Multiplication-Sign 5 {mu}m on target in air. Different from ions with energy of several MeV/u, the very high ion energy of hundred MeV/u level induces problems in beam micro-collimation, online beam spot diagnosis, radiation protection, etc. This paper presents the microbeam setup, difficulties in microbeam formation, and the preliminary experiments performed with the facility.

36 MATERIALS SCIENCE↗

A versatile apparatus for on-line emission channeling experiments

The concept and functionality of an apparatus dedicated to emission channeling experiments using short-lived isotopes on-line at ISOLDE/CERN is described. The setup is assembled in two functional blocks – (a) base stand including beam collimation, implantation and measurement chamber, cryogenic extension, and vacuum control system and (b) Panmure goniometer extension including maneuvering cradle and sample heating furnace. This setup allows for in situ implantation and sample analysis in the as-implanted state and upon cooling down to 50 K and during annealing up to 1200 K. The functionality of the setup will be illustrated with the example of establishing the lattice location of {sup 56}Mn probes implanted into GaAs.

43 PARTICLE ACCELERATORS↗

A first generation compact microbeam radiation therapy system based on carbon nanotube X-ray technology

We have developed a compact microbeam radiation therapy device using carbon nanotube cathodes to create a linear array of narrow focal line segments on a tungsten anode and a custom collimator assembly to select a slice of the resulting wedge-shaped radiation pattern. Effective focal line width was measured to be 131 μm, resulting in a microbeam width of ∼300 μm. The instantaneous dose rate was projected to be 2 Gy/s at full-power. Peak to valley dose ratio was measured to be >17 when a 1.4 mm microbeam separation was employed. Finally, multiple microbeams were delivered to a mouse with beam paths verified through histology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved design of proton source and low energy beam transport line for European Spallation Source

The design update of the European Spallation Source (ESS) accelerator is almost complete and the construction of the prototype of the microwave discharge ion source able to provide a proton beam current larger than 70 mA to the 3.6 MeV Radio Frequency Quadrupole (RFQ) started. The source named PS-ESS (Proton Source for ESS) was designed with a flexible magnetic system and an extraction system able to merge conservative solutions with significant advances. The ESS injector has taken advantage of recent theoretical updates and new plasma diagnostics tools developed at INFN-LNS (Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare). The design strategy considers the PS-ESS and the low energy beam transport line as a whole, where the proton beam behaves like an almost neutralized non-thermalized plasma. Innovative solutions have been used as hereinafter described. Thermo-mechanical optimization has been performed to withstand the chopped beam and the misaligned focused beam over the RFQ input collimator; the results are reported here.

43 PARTICLE ACCELERATORS↗

X-ray spectroscopy of warm and hot electron components in the CAPRICE source plasma at EIS testbench at GSI

An experimental campaign aiming to detect X radiation emitted by the plasma of the CAPRICE source – operating at GSI, Darmstadt – has been carried out. Two different detectors (a SDD – Silicon Drift Detector and a HpGe – hyper-pure Germanium detector) have been used to characterize the warm (2–30 keV) and hot (30–500 keV) electrons in the plasma, collecting the emission intensity and the energy spectra for different pumping wave frequencies and then correlating them with the CSD of the extracted beam measured by means of a bending magnet. A plasma emissivity model has been used to extract the plasma density along the cone of sight of the SDD and HpGe detectors, which have been placed beyond specific collimators developed on purpose. Results show that the tuning of the pumping frequency considerably modifies the plasma density especially in the warm electron population domain, which is the component responsible for ionization processes: a strong variation of the plasma density near axis region has been detected. Potential correlations with the charge state distribution in the plasma are explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the scintillator-based probe for fast-ion losses in the HL-2A tokamak

A new scintillator-based lost fast-ion probe (SLIP) has been developed and operated in the HL-2A tokamak [L. W. Yan, X. R. Duan, X. T. Ding, J. Q. Dong, Q. W. Yang, Yi Liu, X. L. Zou, D. Q. Liu, W. M. Xuan, L. Y. Chen, J. Rao, X. M. Song, Y. Huang, W. C. Mao, Q. M. Wang, Q. Li, Z. Cao, B. Li, J. Y. Cao, G. J. Lei, J. H. Zhang, X. D. Li, W. Chen, J. Chen, C. H. Cui, Z. Y. Cui, Z. C. Deng, Y. B. Dong, B. B. Feng, Q. D. Gao, X. Y. Han, W. Y. Hong, M. Huang, X. Q. Ji, Z. H. Kang, D. F. Kong, T. Lan, G. S. Li, H. J. Li, Qing Li, W. Li, Y. G. Li, A. D. Liu, Z. T. Liu, C. W. Luo, X. H. Mao, Y. D. Pan, J. F. Peng, Z. B. Shi, S. D. Song, X. Y. Song, H. J. Sun, A. K. Wang, M. X. Wang, Y. Q. Wang, W. W. Xiao, Y. F. Xie, L. H. Yao, D. L. Yu, B. S. Yuan, K. J. Zhao, G. W. Zhong, J. Zhou, J. C. Yan, C. X. Yu, C. H. Pan, Y. Liu, and the HL-2A Team , Nucl. Fusion 51, 094016 (2011)] to measure the losses of neutral beam ions. The design of the probe is based on the concept of the α-particle detectors on Tokamak Fusion Test Reactor (TFTR) using scintillator plates. The probe is capable of traveling across an equatorial plane port and sweeping the aperture angle rotationally with respect to the axis of the probe shaft by two step motors, in order to optimize the radial position and the collimator angle. The energy and the pitch angle of the lost fast ions can be simultaneously measured if the two-dimensional image of scintillation light intensity due to the impact of the lost fast ions is detected. Measurements of the fast-ion losses using the probe have been performed during HL-2A neutral beam injection discharges. The clear experimental evidence of enhanced losses of beam ions during disruptions has been obtained by means of the SLIP system. A detailed description of the probe system and the first experimental results are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion-induced gamma-ray detection of fast ions escaping from fusion plasmas

A 12 × 12 pixel detector has been developed and used in a laboratory experiment for lost fast-ion diagnostics. With gamma rays in the MeV range originating from nuclear reactions {sup 9}Be(α, nγ){sup 12}C, {sup 9}Be(d, nγ){sup 12}C, and {sup 12}C(d, pγ){sup 13}C, a high purity germanium (HPGe) detector measured a fine-energy-resolved spectrum of gamma rays. The HPGe detector enables the survey of background-gamma rays and Doppler-shifted photo peak shapes. In the experiments, the pixel detector produces a gamma-ray image reconstructed from the energy spectrum obtained from total photon counts of irradiation passing through the detector's lead collimator. From gamma-ray image, diagnostics are able to produce an analysis of the fast ion loss onto the first wall in principle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress in development of the neutron profile monitor for the large helical device

The neutron profile monitor stably operated at a high-count-rate for deuterium operations in the Large Helical Device has been developed to enhance the research on the fast-ion confinement. It is composed of a multichannel collimator, scintillation-detectors, and a field programmable gate array circuit. The entire neutron detector system was tested using an accelerator-based neutron generator. This system stably acquires the pulse data without any data loss at high-count-rate conditions up to 8 × 10{sup 5} counts per second.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonuniform radiation damage in permanent magnet quadrupoles

We present data that indicate nonuniform magnetization loss due to radiation damage in neodymium-iron-boron Halbach-style permanent magnet quadrupoles. The proton radiography (pRad) facility at Los Alamos uses permanent-magnet quadrupoles for magnifying lenses, and a system recently commissioned at GSI-Darmsdadt uses permanent magnets for its primary lenses. Large fluences of spallation neutrons can be produced in close proximity to these magnets when the proton beam is, intentionally or unintentionally, directed into the tungsten beam collimators; imaging experiments at LANL’s pRad have shown image degradation with these magnetic lenses at proton beam doses lower than those expected to cause damage through radiation-induced reduction of the quadrupole strength alone. We have observed preferential degradation in portions of the permanent magnet quadrupole where the field intensity is highest, resulting in increased high-order multipole components.

36 MATERIALS SCIENCE↗

Diagnostic of fusion neutrons on JET tokamak using diamond detector

In 2011-2012, an experimental campaign with a significant yield of fusion neutrons was carried out on the JET tokamak. During this campaign the facility was equipped with two diamond detectors based on natural and artificial CVD diamond. These detectors were designed and manufactured in State Research Center of Russian Federation TRINITI. The detectors measure the flux of fast neutrons with energies above 0.2 MeV. They have been installed in the torus hall and the distance from the center of plasma was about 3 m. For some of the JET pulses in this experiment, the neutron flux density corresponded to the operational conditions in collimator channels of ITER Vertical Neutron Camera. The main objective of diamond monitors was the measurement of total fast neutron flux at the detector location and the estimation of the JET total neutron yield. The detectors operate as threshold counters. Additionally a spectrometric measurement channel has been configured that allowed us to distinguish various energy components of the neutron spectrum. In this paper we describe the neutron signal measuring and calibration procedure of the diamond detector. Fluxes of DD and DT neutrons at the detector location were measured. It is shown that the signals of total neutron yield measured by the diamond detector correlate with signals measured by the main JET neutron diagnostic based on fission chambers with high accuracy. This experiment can be considered as a successful test of diamond detectors in ITER-like conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Longitudinally excited N{sub 2} laser with low beam divergence

We developed a longitudinally excited N{sub 2} laser (337 nm) with low beam divergence without collimator lenses. The N{sub 2} laser consisted of a 30 cm long Pyrex glass tube with an inner diameter of 2.5 mm, a normal stable resonator formed by flat mirrors, and a simple, novel driver circuit. At a N{sub 2} gas pressure of 0.4 kPa and a repetition rate of 40 Hz, the N{sub 2} laser produced a circular beam with an output energy of 2.6 μJ and a low full-angle beam divergence of 0.29 mrad due to the uniform discharge formed by the longitudinal excitation scheme, the long cavity with the small aperture, and the low-input energy oscillation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗