Search NASA⌕ Search

SEARCH · Search NASA

Results for “data base for model validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Experimental and Numerical Characterization of High Temperature Deformation Behavior of 347H Stainless Steel

This study investigates how temperature affects the plasticity and thermal creep behavior of 347H stainless steel under uniaxial tension. The research combined experimental testing with advanced computational modeling. Two types of experiments were conducted: uniaxial tensile tests at temperatures from 100°C to 750°C using strain rates of ~10⁻⁴ s⁻¹, and creep tests at temperatures between 600°C and 750°C under various stress levels. These experimental results were used to develop and validate a new integrated mechanistic model that can predict material behavior under any loading condition while accounting for both stress and temperature effects. The model was implemented using a polycrystalline microstructure simulation framework based on elasto-viscoplastic Fast Fourier Transform (EVPFFT). It incorporates three key deformation mechanisms: thermally activated dislocation glide, dislocation climb, and vacancy diffusional creep. The model accounts for internal stress distribution within single crystals and considers how precipitates and solute atoms (both interstitial and substitutional) affect dislocation movement. After validation against experimental data, the model was used to generate Ashby-Weertman deformation mechanism maps for 347H steel, providing new insights into how microstructure influences the activation of different creep mechanisms.

Joy, Jobin K.↗

Fiber Optic Instrumentation in High Temperature Irradiation Environments

The extremely harsh conditions of advanced reactor designs pose serious challenges for nuclear fuels and materials. Traditional instrumentation (thermocouples, strain gauges, etc.) are not well suited for extended operation in such a harsh environment. This work discusses the potential for using fiber optic-based instrumentation in high temperature irradiation experiments. The primary limitation of fiber optic instrumentation in irradiation experiments is signal darkening due to attenuation in the fiber material. A computational model has been developed to predict broadband optical attenuation in fused silica fiber materials as a function of time, temperature, and dose. Preliminary results obtained using this model are shown for one cycle of irradiation in the high flux isotope reactor at various temperatures. An irradiation campaign has been initiated to provide temperature-dependent optical attenuation data at high dose in order to validate the predictive model. Demonstration of the safety and reliability of new and enhanced nuclear fuels and materials is essential for improving the safety and reliability of existing nuclear power plants and for the licensing and operation of advanced nuclear reactor technologies. Experimental validation of fuel performance codes requires high fidelity measurements during instrumented irradiation experiments. Therefore, a clear need exists for sensors of unprecedented accuracy, resolution, time/space/energy spectrum dependence, reduced size, and, perhaps most importantly, performance in harsh environments. The harsh environment during accelerated irradiation testing could include temperatures from 300 deg. C up to 2600 deg. C, and radiation damage levels ranging from 1 to greater than 100 dpa. Optical fiber-based sensors are a promising candidate for instrumentation in high temperature irradiation environments. Optical fibers are small, inexpensive, chemically inert, immune to electromagnetic interference, and made of high temperature radiation-hard materials. The ability to make distributed measurements of temperature or strain using a single inexpensive optical fiber currently exists for non-extreme environments as commercially available technology. Other advanced sensing technologies such as laser ultrasound, borescopes, and laser-induced breakdown spectroscopy use fiber optic light delivery as a critical component of the sensor design. Some potential applications for optical fiber-based sensors in instrumented irradiation experiments include in-situ measurements of thermal conductivity, ultrasonic measurement of elastic constants (with fiber optic delivery of signal for generation and detection of ultrasonic wave), and distributed measurements of temperature and/or strain (i.e., swelling). The primary limitation for the use of optical technologies for harsh environment (e.g., high neutron flux reactor environments) instrumentation is the attenuation of the light signal due to the effects of temperature and/or irradiation. This work summarizes initial efforts towards developing a predictive model of temperature-dependent radiation-induced attenuation in fused silica optical fibers at high dose. If there is adequate transmission in the fibers, fiber optic-based instrumentation could provide highly accurate distributed measurements during instrumented fuel/material irradiation experiments. Preliminary results show attenuation on the order of 5- 10 dB/m in the wavelength range of 750-900 nm at temperatures of 300 deg. C and below after one HFIR cycle (24 days). At higher temperatures (600 and 900 deg. C), the attenuation is reduced below 5 dB/m in the same wavelength range. This amount of attenuation is acceptable for most fiber optic based sensor systems with a dynamic range on the order of 20-50 dB for a reasonable length (1-2 meters) of fiber in the high flux region. Many optical components use a wavelength of 850 nm, which lies in the low attenuation window. In order to refine and ultimately validate the predictive model of optical fiber attenuation, a reactor irradiation campaign has been initiated. Rabbit irradiation capsules have been designed to irradiate optical fiber material (low and high OH fused silica, as well as single crystal sapphire) specimens in the HFIR at temperatures ranging from 100 to 1200 deg. C. (authors)

42 ENGINEERING↗

Development and Validation of Scale Nuclear Analysis Methods for High Temperature Gas-Cooled Reactors

In support of the U.S. Nuclear Regulatory Commission, ORNL is updating the nuclear analysis methods and data in the SCALE code system to support modeling of HTGRs. Development activities include methods used for reactor physics, criticality safety, and radiation shielding. This paper focuses on the nuclear methods in support of reactor physics, which primarily include lattice physics for cross-section processing of both prismatic and pebble-bed designs, Monte Carlo depletion methods and efficiency improvements for double heterogeneous fuels, and validation against relevant experiments. These methods enhancements are being validated using available experimental data from the HTTR and HTR-10 startup and initial criticality experiments. Results obtained with three-dimensional Monte Carlo models of the HTTR initial core critical configurations with SCALE6/KENO show excellent agreement between the continuous energy and multigroup methods and the results are consistent with results obtained by others. A three-dimensional multigroup Monte Carlo model for the initial critical core of the HTR-10 has been developed with SCALE6/KENO based on the benchmark specifications included in the IRPhE Handbook. The core eigenvalue obtained with this model is in very good agreement with the corresponding value obtained with a consistent continuous energy MCNP5 core model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MO-FG-209-05: Towards a Feature-Based Anthropomorphic Model Observer

This symposium will review recent advances in the simulation methods for evaluation of novel breast imaging systems – the subject of AAPM Task Group TG234. Our focus will be on the various approaches to development and validation of software anthropomorphic phantoms and their use in the statistical assessment of novel imaging systems using such phantoms along with computational models for the x-ray image formation process. Due to the dynamic development and complex design of modern medical imaging systems, the simulation of anatomical structures, image acquisition modalities, and the image perception and analysis offers substantial benefits of reduced cost, duration, and radiation exposure, as well as the known ground-truth and wide variability in simulated anatomies. For these reasons, Virtual Clinical Trials (VCTs) have been increasingly accepted as a viable tool for preclinical assessment of x-ray and other breast imaging methods. Activities of TG234 have encompassed the optimization of protocols for simulation studies, including phantom specifications, the simulated data representation, models of the imaging process, and statistical assessment of simulated images. The symposium will discuss the state-of-the-science of VCTs for novel breast imaging systems, emphasizing recent developments and future directions. Presentations will discuss virtual phantoms for intermodality breast imaging performance comparisons, extension of the breast anatomy simulation to the cellular level, optimized integration of the simulated imaging chain, and the novel directions in the observer models design. Learning Objectives: Review novel results in developing and applying virtual phantoms for inter-modality breast imaging performance comparisons; Discuss the efforts to extend the computer simulation of breast anatomy and pathology to the cellular level; Summarize the state of the science in optimized integration of modules in the simulated imaging chain; Compare novel directions in the design of observer models for task based validation of imaging systems. PB: Research funding support from the NIH, NSF, and Komen for the Cure; NIH funded collaboration with Barco, Inc. and Hologic, Inc.; Consultant to Delaware State Univ. and NCCPM, UK. AA: Employed at Barco Healthcare.; P. Bakic, NIH: (NIGMS P20 #GM103446, NCI R01 #CA154444); M. Das, NIH Research grants.

60 APPLIED LIFE SCIENCES↗

Validation of a FBC model for co-firing of hazelnut shell with lignite against experimental data

Performance of a comprehensive system model extended for modelling of co-firing of lignite and biomass was assessed by applying it to METU 0.3 MW{sub t} Atmospheric Bubbling Fluidized Bed Combustor co-firing lignite with hazelnut shell and validating its predictions against on-line temperature and concentration measurements of O{sub 2}, CO{sub 2}, CO, SO{sub 2} and NO along the same test rig fired with lignite only, lignite with limestone addition and lignite with biomass and limestone addition. The system model accounts for hydrodynamics; volatiles release and combustion, char combustion, particle size distribution for lignite and biomass; entrainment; elutriation; sulfur retention and NO formation and reduction, and is based on conservation equations for energy and chemical species. Special attention was paid to different devolatilization characteristics of lignite and biomass. A volatiles release model based on a particle movement model and a devolatilization kinetic model were incorporated into the system model separately for both fuels. Kinetic parameters for devolatilization were determined via thermogravimetric analysis. Predicted and measured temperatures and concentrations of gaseous species along the combustor were found to be in good agreement. Introduction of biomass to lignite was found to decrease SO{sub 2} emissions but did not affect NO emissions significantly. The system model proposed in this study proves to be a useful tool in qualitatively and quantitatively simulating the processes taking place in a bubbling fluidized bed combustor burning lignite with biomass. (author)

01 COAL, LIGNITE, AND PEAT↗

A machine learning approach for identifying variables associated with risk of developing neutralizing antidrug antibodies to factor VIII

A key unmet need in the management of hemophilia A (HA) is the lack of clinically validated markers that are associated with the development of neutralizing antibodies to Factor VIII (FVIII) (commonly referred to as inhibitors). This study aimed to identify relevant biomarkers for FVIII inhibition using Machine Learning (ML) and Explainable AI (XAI) using the My Life Our Future (MLOF) research repository. The dataset includes biologically relevant variables such as age, race, sex, ethnicity, and the variants in the F8 gene. In addition, we previously carried out Human Leukocyte Antigen Class II (HLA-II) typing on samples obtained from the MLOF repository. Using this information, we derived other patient-specific biologically and genetically important variables. These included identifying the number of foreign FVIII derived peptides, based on the alignment of the endogenous FVIII and infused drug sequences, and the foreign-peptide HLA-II molecule binding affinity calculated using NetMHCIIpan. The data were processed and trained with multiple ML classification models to identify the top performing models. The top performing model was then chosen to apply XAI via SHAP, (SHapley Additive exPlanations) to identify the variables critical for the prediction of FVIII inhibitor development in a hemophilia A patient. Using XAI we provide a robust and ranked identification of variables that could be predictive for developing inhibitors to FVIII drugs in hemophilia A patients. These variables could be validated as biomarkers and used in making clinical decisions and during drug development. The top five variables for predicting inhibitor development based on SHAP values are: (i) the baseline activity of the FVIII protein, (ii) mean affinity of all foreign peptides for HLA DRB 3, 4, & 5 alleles, (iii) mean affinity of all foreign peptides for HLA DRB1 alleles), (iv) the minimum affinity among all foreign peptides for HLA DRB1 alleles, and (v) F8 mutation type.

60 APPLIED LIFE SCIENCES↗

Self-Healing Attack-Resilient PMU Network for Power System Operation

In this paper, we propose a self-healing phasor measurement unit (PMU) network that exploits the features of dynamic and programmable configuration in a software-defined networking infrastructure to achieve resiliency against cyber-attacks. After a cyber-attack, the configuration of network switches is changed to isolate the compromised PMUs/phasor data concentrators to prevent further propagation of the attack; meanwhile, the disconnected yet uncompromised PMUs will be reconnected to the network to "self-heal" and thus restore the observability of the power system. Specifically, we formulate an integer linear programming model to minimize the overhead of the self-healing process (e.g., the recovery latency), while considering the constraints of power system observability, hardware resources, and network topology. We also propose a heuristic algorithm to decrease the computational complexity. Case studies of a PMU network based on the IEEE 30-bus and 118-bus systems are used to validate the effectiveness of the self-healing mechanism.

Cybersecurity↗

3D delivered dose assessment using a 4DCT-based motion model

Purpose: The purpose of this work is to develop a clinically feasible method of calculating actual delivered dose distributions for patients who have significant respiratory motion during the course of stereotactic body radiation therapy (SBRT). Methods: A novel approach was proposed to calculate the actual delivered dose distribution for SBRT lung treatment. This approach can be specified in three steps. (1) At the treatment planning stage, a patient-specific motion model is created from planning 4DCT data. This model assumes that the displacement vector field (DVF) of any respiratory motion deformation can be described as a linear combination of some basis DVFs. (2) During the treatment procedure, 2D time-varying projection images (either kV or MV projections) are acquired, from which time-varying “fluoroscopic” 3D images of the patient are reconstructed using the motion model. The DVF of each timepoint in the time-varying reconstruction is an optimized linear combination of basis DVFs such that the 2D projection of the 3D volume at this timepoint matches the projection image. (3) 3D dose distribution is computed for each timepoint in the set of 3D reconstructed fluoroscopic images, from which the total effective 3D delivered dose is calculated by accumulating deformed dose distributions. This approach was first validated using two modified digital extended cardio-torso (XCAT) phantoms with lung tumors and different respiratory motions. The estimated doses were compared to the dose that would be calculated for routine 4DCT-based planning and to the actual delivered dose that was calculated using “ground truth” XCAT phantoms at all timepoints. The approach was also tested using one set of patient data, which demonstrated the application of our method in a clinical scenario. Results: For the first XCAT phantom that has a mostly regular breathing pattern, the errors in 95% volume dose (D95) are 0.11% and 0.83%, respectively for 3D fluoroscopic images reconstructed from kV and MV projections compared to the ground truth, which is clinically comparable to 4DCT (0.093%). For the second XCAT phantom that has an irregular breathing pattern, the errors are 0.81% and 1.75% for kV and MV reconstructions, both of which are better than that of 4DCT (4.01%). In the case of real patient, although it is impossible to obtain the actual delivered dose, the dose estimation is clinically reasonable and demonstrates differences between 4DCT and MV reconstruction-based dose estimates. Conclusions: With the availability of kV or MV projection images, the proposed approach is able to assess delivered doses for all respiratory phases during treatment. Compared to the planning dose based on 4DCT, the dose estimation using reconstructed 3D fluoroscopic images was as good as 4DCT for regular respiratory pattern and was a better dose estimation for the irregular respiratory pattern.

60 APPLIED LIFE SCIENCES↗

Robust Ceramic Coaxial Cable Down-Hole Sensors for Long-Term In Situ Monitoring of Geologic CO 2 Injection and Storage

Energy generation by use of fossil fuels produces large volumes of CO 2 and other greenhouse gases, whose accumulation in the atmosphere is widely seen as undesirable. CO 2 Capture followed by sequestration has been identified as the solution. Subsurface geologic formations offer a potential location for long-term storage of CO 2 because of their requisite size. Unfortunately, the inaccessibility and complexity of the subsurface, the wide range of scales of variability, and the coupled nonlinear processes, impose tremendous challenges to determine the transport and predict the fate of the stored CO 2 . Among the various monitoring approaches, in situ down-hole monitoring of the various state parameters provides critical and direct data points that can be used to validate the models, optimize the injection, detect leakage and track the CO 2 plume. However, down-hole sensors that can withstand the harsh conditions and operate over decades of the project lifecycle remain unavailable. Given that the widespread of carbon capture and storage will be the necessity and reality in the future, fundamental and applied research is required to address the significant challenges and technological gaps in lack of long-term reliable down-hole sensors This project focused on the development and demonstration of a novel, low-cost, distributed, robust ceramic coaxial cable sensor platform for in situ down-hole monitoring of geologic CO 2 injection and storage with high spatial and temporal resolutions. The coaxial cable Fabry-Perot interferometer (CCFPI) has been studied as a general sensor platform for in situ, long-term, measurement of temperature, pressure and strain, which are critical to CO 2 injection and storage. A novel signal processing scheme has been developed and demonstrated for dense multiplexing of the sensors for low-cost distributed sensing with high spatial resolution. The developed temperature, pressure and strain sensors have been extensively tested under laboratory conditions that are similar to the downhole CO 2 storage environment, showing excellent capability for in situ monitoring the various parameters that are important to model, optimize the injection, detect leakage and track the CO 2 plume. In addition, the interactions between the sensor datum and the geological models have been investigated in details for the purposes of model validation, guiding sensor installation/placement, enhancement of model prediction capability and optimization of the injection processes. This project has resulted in the successful development of new ceramic coaxial cable based sensor systems that can monitor directly the changes in pressure, temperature, and strain caused by increased reservoir pressure and reduced reservoir temperature due to the supercritical CO 2 injection. Integrated with geological models, the sensors and measurement data can improve the possibility to identify plume movement and leakage in the cap rock and wells with higher precision and more accuracy. The low cost, ease of deployment, small size and dense multiplexing features of the new sensing technology will allow a large number of sensors to be deployed to address the objective to demonstrate that 99% of the CO 2 remains in the injection zone.

01 COAL, LIGNITE, AND PEAT↗

Sci—Thur AM: YIS - 06: An EPID-based 3D patient dose verification method for SBRT-VMAT delivery

Purpose: Stereotactic body radiation therapy (SBRT) delivered via volumetric modulated arc therapy (VMAT) can strongly benefit from an in vivo patient dose verification due to the large doses per fraction. Electronic portal imaging devices (EPIDs) can be utilized as a patient dose dosimeter. In this work we present a physics-based model which utilizes on-treatment EPID images to reconstruct the dose delivered to an anthropomorphic phantom during SBRT-VMAT delivery. Methods: An SBRT linac beam was modeled using Monte Carlo methods and verified with measured data. Our dose reconstruction model back-projects EPID measured focal fluence upstream of the patient and adds a predicted extra-focal fluence component. This fluence is forward projected onto the patient's density matrix and convolved with dose kernels to calculate dose. The model was validated for two prostate, three lung, and two spine SBRT-VMAT treatments. Results were compared to the treatment planning system's calculation. Results: 2%/2 mm chi comparison calculations gave pass rates for the whole volume, infield, and high dose region respectively, and no lower than: 98%, 95%, 99% for the prostate plans, 99%, 92%, 85% for the lung plans, and 91%, 85%, 81% for the spine plans. A 3%/3mm calculation gave pass rates no lower than 99%, 94%, and 90% for all dose regions for the prostate, lung, and spine respectively. Conclusions: We have developed a physics-based model which calculates delivered dose to phantom (or patient) for SBRT-VMAT delivery using on treatment EPID images. The accuracy of the results has allowed us to test this model clinically.

60 APPLIED LIFE SCIENCES↗

SU-E-T-673: Recent Developments and Comprehensive Validations of a GPU-Based Proton Monte Carlo Simulation Package, GPMC

Purpose: A GPU-based Monte Carlo (MC) simulation package gPMC has been previously developed and high computational efficiency was achieved. This abstract reports our recent improvements on this package in terms of accuracy, functionality, and code portability. Methods: In the latest version of gPMC, nuclear interaction cross section database was updated to include data from TOPAS/Geant4. Inelastic interaction model, particularly the proton scattering angle distribution, was updated to improve overall simulation accuracy. Calculation of dose averaged LET (LETd) was implemented. gPMC was ported onto an OpenCL environment to enable portability across different computing devices (GPUs from different vendors and CPUs). We also performed comprehensive tests of the code accuracy. Dose from electro-magnetic (EM) interaction channel, primary and secondary proton doses and fluences were scored and compared with those computed by TOPAS. Results: In a homogeneous water phantom with 100 and 200 MeV beams, mean dose differences in EM channel computed by gPMC and by TOPAS were 0.28% and 0.65% of the corresponding maximum dose, respectively. With the Geant4 nuclear interaction cross section data, mean difference of primary proton dose was 0.84% for the 200 MeV case and 0.78% for the 100 MeV case. After updating inelastic interaction model, maximum difference of secondary proton fluence and dose were 0.08% and 0.5% for the 200 MeV beam, and 0.04% and 0.2% for the 100 MeV beam. In a test case with a 150MeV proton beam, the mean difference between LETd computed by gPMC and TOPAS was 0.96% within the proton range. With the OpenCL implementation, gPMC is executable on AMD and Nvidia GPUs, as well as on Intel CPU in single or multiple threads. Results on different platforms agreed within statistical uncertainty. Conclusion: Several improvements have been implemented in the latest version of gPMC, which enhanced its accuracy, functionality, and code portability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PRIME: An evaluation framework for protein representation inference and generalization in viral mutation space

Background Protein language models (PLMs) have revolutionized protein fitness prediction, yet their application to rapidly evolving viral pathogens is often confounded by extreme sequence homology. This homology leads to “data leakage” in standard random validation splits, yielding inflated performance metrics that fail to translate into real-world biosurveillance utility. Results We present Protein Representation Inference for Mutation Evaluation (PRIME), a framework that integrates domain-specific fine-tuning with a rigorous position-stratified validation protocol to evaluate viral threats. Using a dataset of 347,432 SARS-CoV-2 receptor binding domain (RBD) sequences, we demonstrate that while random training data split yields deceptive R 2 values (> 0.90), they fail to generalize to novel mutational sites. By benchmarking models up to 650 M parameters, we show that domain-specific fine-tuning of the ESM-C 600 M model with correctly stratified data provides an initial demonstration of predictive signal for binding affinity and expression at unseen mutational sites of binding affinity and expression on unseen sites (R 2 ~0.23), a significant advancement over base foundation models which exhibit no predictive power (R 2 <0). PRIME’s embedding-based clustering identified 3.03% of bat coronavirus sequences as candidates for further experimental prioritization based on their functional similarity to human-infective strains in embedding space, offering a perspective complementary to traditional phylogenetic methods. Conclusion PRIME establishes a new benchmark for the application of PLMs in pathogen surveillance. Our findings demonstrate that state-of-the-art models and fine-tuning, when paired with stratified validation, provide biologically meaningful insights into pathogen evolution and zoonotic risk.

59 BASIC BIOLOGICAL SCIENCES↗

On the dynamics and kinematics of two-fluid-phase flow in porous media

A model formulated in terms of both conservation and kinematic equations for phases and interfaces in two-fluid-phase flow in a porous medium system is summarized. Macroscale kinematic equations are derived as extensions of averaging theorems and do not rely on conservation principles. Models based on both conservation and kinematic equations can describe multiphase flow with varying fidelity.When only phase-based equations are considered, a model similar in form to the traditional model for two-fluid-phase flow results. When interface conservation and kinematic equations are also included, a novel formulation results that naturally includes evolution equations that express dynamic changes in fluid saturations, pressures, the capillary pressure, and the fluid-fluid interfacial area density in a two-fluid-system. This dynamic equation set is unique to this work, and the importance of the modeled physics is shown through both microfluidic experiments and high-resolution lattice Boltzmann simulations. The validation work shows that the relaxation of interface distribution and shape toward an equilibrium state is a slow process relativeto the time scale typically allowed for a system to approach an apparent equilibrium state based upon observations of fluid saturations and external pressure measurements. Consequently, most pressure-saturation data intended to denote an equilibrium state are likely a sampling from a dynamic system under-going changes of interfacial curvatures that are not typically monitored. The results confirm the importance of kinematic analysis in combination with conservation equations for faithful modeling of system physics.

54 ENVIRONMENTAL SCIENCES↗

Wave and Offshore Wind Resource in the U.S. Pacific Ocean Minor Outlying Islands

Coastal environments such as islands have unique opportunities for renewable energy resources. This work explores the wave and offshore wind energy potential for the U.S. Pacific Ocean Minor Outlying Islands, including Baker Island, Howland Island, Jarvis Island, Johnston Atoll, Kingman Reef, Palmyra Atoll, and Wake Island. A numerical wave model based on WAVEWATCH III and SWAN (both are NWS / NOAA models) was developed, validated, and executed to generate a 32-year hindcast dataset suitable for resource characterization for each island. A complementary offshore wind resource characterization is provided for the same time period based on the European Centre for Medium-Range Weather Forecasts (ECMWF) Reanalysis v5 (ERA5). Each island has five netcdf files: 1. wave_[island]_annual_J_map.nc: the data used to generate the map of annual averaged omnidirectional wave power (J [kW/m]) 2. wave_[island]_100m_IEC: six IEC parameters at 100m isobath from 1979/01/01 to 2020/12/31, output hourly 3. wave_[island]_5km_IEC: six IEC parameters at 5km from the shoreline 1979/01/01 to 2020/12/31, output hourly 4. wind_island_100mASL_windspeed_timeseries.nc: wind speed timeseries from ERA5 at 100 m above sea level within a 60 km radius of the island (m/s) 1979/01/01 to 2010/12/31, output hourly 5. wind_island_100mASL_winddirection_timeseries.nc: wind direction timeseries from ERA5 at 100 m above sea level within a 60 km radius of the island (degrees) 1979/01/01 to 2010/12/31, output hourly

16 TIDAL AND WAVE POWER↗

Development of a Modeling Approach to Describe Thermal Conductivity of Prototypic SiC-SiC tubes for LWR Fuel Cladding

SiC-SiC composites are a promising material intended to be used as a for fuel cladding for Light Water Reactors (LWRs). This material has a high steam oxidation resistance, high strength and low neutron cross section. Thermal conductivity is one of the most important physical properties for assessing the performance of SiC based fuel cladding. However, there is a significant lack of data for tube materials because measurement is challenging owing to the specimen geometry. This report summarizes the modeling methodology, experimental methodologies and software that will be used to study the thermal conductivity of different SiC-SiC composite tubes. The proposed experiments described here, are directed to create a baseline of thermal conductivity values to validate experimental simulations. In order to obtain the thermal conductivity of these materials the Laser Flash Analysis (LFA) will be implemented to obtain the thermal diffusivity of flat and sections of round shape specimens. Thermal diffusivity experiments will be complemented by Finite Element Method (FEM) simulations and a branch of this methodology known as Image-Based Finite Element Method (IBFEM). The FEM simulations will help to identify the possible limitations of experimental measurements in round shape specimens and verify the results of experiments in flat shape samples. The results of the IBFEM will help to quantify the possible effects of porosity in SiC-SiC composites. The findings of the aforementioned activities will be also applied to SiC-SiC neutron irradiated tube samples in order to capture the damage produced by this ageing mechanism.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Overview of Scale 6.2

SCALE is an industry-leading suite of tools for nuclear systems modeling and simulation that provides comprehensive, verified and validated, user-friendly capabilities for criticality safety, reactor physics, radiation shielding, and sensitivity and uncertainty analysis. For more than 30 years, regulators, licensees, and research institutions around the world have used SCALE for nuclear safety analysis and design. SCALE provides a plug-and-play framework that includes three deterministic and three Monte Carlo radiation transport solvers that are selected based on the desired solution. SCALE includes the latest nuclear data libraries for continuous-energy and multigroup radiation transport as well as activation, depletion, and decay calculations. SCALE s graphical user interfaces assist with accurate system modeling, visualization, and convenient access to desired results. SCALE 6.2 provides several new capabilities and significant improvements in many existing features, especially with expanded CE Monte Carlo capabilities for criticality safety, shielding, depletion, and sensitivity and uncertainty analysis. A brief overview of SCALE capabilities is provided with emphasis on new features for SCALE 6.2.

97 MATHEMATICS AND COMPUTING↗

Enhancements in Continuous-Energy Monte Carlo Capabilities for SCALE 6.2

SCALE is a widely used suite of tools for nuclear systems modeling and simulation that provides comprehensive, verified and validated, user-friendly capabilities for criticality safety, reactor physics, radiation shielding, and sensitivity and uncertainty analysis. For more than 30 years, regulators, industry, and research institutions around the world have used SCALE for nuclear safety analysis and design. SCALE provides a plug-and-play framework that includes three deterministic and three Monte Carlo radiation transport solvers that are selected based on the desired solution. SCALE includes the latest nuclear data libraries for continuous-energy and multigroup radiation transport as well as activation, depletion, and decay calculations. SCALE s graphical user interfaces assist with accurate system modeling, visualization, and convenient access to desired results. SCALE 6.2 provides several new capabilities and significant improvements in many existing features, especially with expanded continuous-energy Monte Carlo capabilities for criticality safety, shielding, depletion, sensitivity and uncertainty analysis, and improved fidelity in nuclear data libraries. A brief overview of SCALE capabilities is provided with emphasis on new features for SCALE 6.2.

Continuous-Energy↗

Monte Carlo capabilities of the SCALE code system

SCALE is a broadly used suite of tools for nuclear systems modeling and simulation that provides comprehensive, verified and validated, user-friendly capabilities for criticality safety, reactor physics, radiation shielding, and sensitivity and uncertainty analysis. For more than 30 years, regulators, licensees, and research institutions around the world have used SCALE for nuclear safety analysis and design. SCALE provides a “plug-and-play” framework that includes three deterministic and three Monte Carlo radiation transport solvers that can be selected based on the desired solution, including hybrid deterministic/Monte Carlo simulations. SCALE includes the latest nuclear data libraries for continuous-energy and multigroup radiation transport as well as activation, depletion, and decay calculations. SCALE’s graphical user interfaces assist with accurate system modeling, visualization, and convenient access to desired results. SCALE 6.2 will provide several new capabilities and significant improvements in many existing features, especially with expanded continuous-energy Monte Carlo capabilities for criticality safety, shielding, depletion, and sensitivity and uncertainty analysis. Finally, an overview of the Monte Carlo capabilities of SCALE is provided here, with emphasis on new features for SCALE 6.2.

97 MATHEMATICS AND COMPUTING↗