TU-AB-BRC-05: Creation of a Monte Carlo TrueBeam Model by Reproducing Varian Phase Space Data

Purpose: To create a Varian TrueBeam 6 MV FFF Monte Carlo model using BEAMnrc/EGSnrc that accurately reproduces the Varian representative dataset, followed by tuning the model’s source parameters to accurately reproduce in-house measurements. Methods: A BEAMnrc TrueBeam model for 6 MV FFF has been created by modifying a validated 6 MV Varian CL21EX model. Geometric dimensions and materials were adjusted in a trial and error approach to match the fluence and spectra of TrueBeam phase spaces output by the Varian VirtuaLinac. Once the model’s phase space matched Varian’s counterpart using the default source parameters, it was validated to match 10 × 10 cm{sup 2} Varian representative data obtained with the IBA CC13. The source parameters were then tuned to match in-house 5 × 5 cm{sup 2} PTW microDiamond measurements. All dose to water simulations included detector models to include the effects of volume averaging and the non-water equivalence of the chamber materials, allowing for more accurate source parameter selection. Results: The Varian phase space spectra and fluence were matched with excellent agreement. The in-house model’s PDD agreement with CC13 TrueBeam representative data was within 0.9% local percent difference beyond the first 3 mm. Profile agreement at 10 cm depth was within 0.9% local percent difference and 1.3 mm distance-to-agreement in the central axis and penumbra regions, respectively. Once the source parameters were tuned, PDD agreement with microDiamond measurements was within 0.9% local percent difference beyond 2 mm. The microDiamond profile agreement at 10 cm depth was within 0.6% local percent difference and 0.4 mm distance-to-agreement in the central axis and penumbra regions, respectively. Conclusion: An accurate in-house Monte Carlo model of the Varian TrueBeam was achieved independently of the Varian phase space solution and was tuned to in-house measurements. KO acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290).

60 APPLIED LIFE SCIENCES↗

TU-H-BRC-05: Stereotactic Radiosurgery Optimized with Orthovoltage Beams

Purpose: To achieve improved stereotactic radiosurgery (SRS) dose distributions using orthovoltage energy fluence modulation with inverse planning optimization techniques. Methods: A pencil beam model was used to calculate dose distributions from the institution’s orthovoltage unit at 250 kVp. Kernels for the model were derived using Monte Carlo methods as well as measurements with radiochromic film. The orthovoltage photon spectra, modulated by varying thicknesses of attenuating material, were approximated using open-source software. A genetic algorithm search heuristic routine was used to optimize added tungsten filtration thicknesses to approach rectangular function dose distributions at depth. Optimizations were performed for depths of 2.5, 5.0, and 7.5 cm, with cone sizes of 8, 10, and 12 mm. Results: Circularly-symmetric tungsten filters were designed based on the results of the optimization, to modulate the orthovoltage beam across the aperture of an SRS cone collimator. For each depth and cone size combination examined, the beam flatness and 80–20% and 90–10% penumbrae were calculated for both standard, open cone-collimated beams as well as for the optimized, filtered beams. For all configurations tested, the modulated beams were able to achieve improved penumbra widths and flatness statistics at depth, with flatness improving between 33 and 52%, and penumbrae improving between 18 and 25% for the modulated beams compared to the unmodulated beams. Conclusion: A methodology has been described that may be used to optimize the spatial distribution of added filtration material in an orthovoltage SRS beam to result in dose distributions at depth with improved flatness and penumbrae compared to standard open cones. This work provides the mathematical foundation for a novel, orthovoltage energy fluence-modulated SRS system.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRA-02: Automated Triplet Beam Orientation Optimization for MRI-Guided Co-60 Radiotherapy

Purpose: MRI guided Co-60 provides daily and intrafractional MRI soft tissue imaging for improved target tracking and adaptive radiotherapy. To remedy the low output limitation, the system uses three Co-60 sources at 120° apart, but using all three sources in planning is considerably unintuitive. We automate the beam orientation optimization using column generation, and then solve a novel fluence map optimization (FMO) problem while regularizing the number of MLC segments. Methods: Three patients—1 prostate (PRT), 1 lung (LNG), and 1 head-and-neck boost plan (H&NBoost)—were evaluated. The beamlet dose for 180 equally spaced coplanar beams under 0.35 T magnetic field was calculated using Monte Carlo. The 60 triplets were selected utilizing the column generation algorithm. The FMO problem was formulated using an L2-norm minimization with anisotropic total variation (TV) regularization term, which allows for control over the number of MLC segments. Our Fluence Regularized and Optimized Selection of Triplets (FROST) plans were compared against the clinical treatment plans (CLN) produced by an experienced dosimetrist. Results: The mean PTV D95, D98, and D99 differ by −0.02%, +0.12%, and +0.44% of the prescription dose between planning methods, showing same PTV dose coverage. The mean PTV homogeneity (D95/D5) was at 0.9360 (FROST) and 0.9356 (CLN). R50 decreased by 0.07 with FROST. On average, FROST reduced Dmax and Dmean of OARs by 6.56% and 5.86% of the prescription dose. The manual CLN planning required iterative trial and error runs which is very time consuming, while FROST required minimal human intervention. Conclusions: MRI guided Co-60 therapy needs the output of all sources yet suffers from unintuitive and laborious manual beam selection processes. Automated triplet orientation optimization is shown essential to overcome the difficulty and improves the dosimetry. A novel FMO with regularization provides additional controls over the number of MLC segments and treatment time. Varian Medical Systems; NIH grant R01CA188300; NIH grant R43CA183390.

60 APPLIED LIFE SCIENCES↗

Poster - 22: Retrospective analysis of portal dosimetry based QA of Prostate VMAT Plans

Purpose: The purpose of this study is to retrospectively analyze the portal dosimetry based quality assurance of prostate VMAT plans. Methods: Our standard quality assurance of VMAT treatment plans are performed using EPID installed on Varian TrueBeam Linac. In our current study we analyzed 84 prostate pretreatment VMAT plans. All plans consisted of two arcs, 7800cGy in 39 fractions with a 6MV beam. For each of these VMAT plans, the measured fluence for each arc is compared with the reference fluence using gamma index analysis. Results: We have compared the gamma passing rates for three criteria; 3%/3mm, 2%/2mm and 1%/1mm. Out of 168 arcs measured, the number below the gamma passing rate 95% using the area, Field+1cm, are 0, 2, and 124 for 3%/3mm, 2%/2mm and 1%/1mm criteria respectively. Corresponding numbers for MLC CIAO are 0, 2, and 139 respectively. The average gamma passing rate for all arcs measured using Field+1cm are 99.9±0.4, 99.6±1.2, and 90.9±6.5 for 3%/3mm, 2%/2mm and 1%/1mm respectively. Similarly if the MLC CIAO area is analyzed, a passing rate of 99.9±0.2, 99.2±1.2 and 87.2±8.5 respectively was observed. The average of the maximum gamma was also found to increase with tighter criteria. Conclusion: Analysis of prostate VMAT quality assurance plans indicate that the gamma passing rate is sensitive to the criteria and the area analyzed.

60 APPLIED LIFE SCIENCES↗

Ultrafast changes in the optical properties of a titanium surface and femtosecond laser writing of one-dimensional quasi-periodic nanogratings of its relief

One-dimensional quasi-periodic nanogratings with spacings in the range from 160 to 600 nm are written on a dry or wet titanium surface exposed to linearly polarized femtosecond IR and UV laser pulses with different surface energy densities. The topological properties of the obtained surface nanostructures are studied by scanning electron microscopy. Despite the observation of many harmonics of the one-dimensional surface relief in its Fourier spectra, a weak decreasing dependence of the first-harmonic wavenumber (nanograting spacing) on the laser fluence is found. Studies of the instantaneous optical characteristics of the material during laser irradiation by measuring the reflection of laser pump pulses and their simulation based on the Drude model taking into account the dominant interband absorption allowed us to estimate the length of the excited surface electromagnetic (plasmon-polariton) wave for different excitation conditions. This wavelength is quantitatively consistent with the corresponding nanograting spacings of the first harmonic of the relief of the dry and wet titanium surfaces. It is shown that the dependence of the first-harmonic nanograting spacing on the laser fluence is determined by a change in the instantaneous optical characteristics of the material and the saturation of the interband absorption along with the increasing role of intraband transitions. Three new methods are proposed for writing separate subwave surface nanogratings or their sets by femtosecond laser pulses using the near-threshold nanostructuring, the forced adjustment of the optical characteristics of the material or selecting the spectral range of laser radiation, and also by selecting an adjacent dielectric.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preablation electron and lattice dynamics on the silicon surface excited by a femtosecond laser pulse

The study of the time-resolved optical reflection from the silicon surface excited by single femtosecond laser pulses below and near the melting threshold reveals fast (less than 10 ps) Auger recombination of a photogenerated electron–hole plasma with simultaneous energy transfer to the lattice. The acoustic relaxation of the excited surface layer indicates (according to reported data) a characteristic depth of 150 nm of the introduction of the laser radiation energy, which is related to direct linear laser radiation absorption in the photoexcited material due to a decrease in the energy bandgap. The surface temperature, which is probed at a time delay of about 100 ps from the reflection thermomodulation of probe radiation and the integrated continuous thermal emission from the surface, increases with the laser fluence and, thus, favors a nonlinear increase in the fluorescence of sublimated silicon atoms. The surface temperature estimated near the picosecond melting threshold demonstrates a substantial (20%) overheating of the material with respect to the equilibrium melting temperature. Above the melting threshold, the delay of formation of the material melt decreases rapidly (from several tens of picoseconds to several fractions of a picosecond) when the laser fluence and, correspondingly, the surface temperature increase. In the times of acoustic relaxation of the absorbing layer and even later, the time modulation of the optical reflectivity of the material demonstrates acoustic reverberations with an increasing period, which are related to the formation of melt nuclei in the material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multijunction GaInP/GaInAs/Ge solar cells with Bragg reflectors

Effect of subcell parameters on the efficiency of GaInP/Ga(In)As/Ge tandem solar cells irradiated with 1-MeV electrons at fluences of up to 3 x 10{sup 15} cm{sup -2} has been theoretically studied. The optimal thicknesses of GaInP and GaInAs subcells, which provide the best photocurrent matching at various irradiation doses in solar cells with and without built-in Bragg reflectors, were determined. The dependences of the photoconverter efficiency on the fluence of 1-MeV electrons and on the time of residence in the geostationary orbit were calculated for structures optimized to the beginning and end of their service lives. It is shown that the optimization of the subcell heterostructures for a rated irradiation dose and the introduction of Bragg reflectors into the structure provide a 5% overall increase in efficiency for solar cells operating in the orbit compared with unoptimized cells having no Bragg reflector.

36 MATERIALS SCIENCE↗

Charge spectroscopy of SiO{sub 2} layers with embedded silicon nanocrystals modified by irradiation with high-energy ions

The method of charge deep-level transient spectroscopy (Q-DLTS) is used to study and compare the ejection of charge carriers from silicon nanocrystals (NCs) located in an ordered or random way in the SiO{sub 2} matrix. It is shown that, in all cases, this ejection is a thermally activated process. The parameters of energy barriers characterizing the processes of ejection of charge carriers from the levels of nanocrystals in the layers NCs:SiO{sub 2} before (random distribution) and after their modification by irradiation with high-energy ions (ordered distribution of nanocrystals) are determined. It is found that the activation energies for ejection of charge carriers from nanocrystals and the size of nanocrystals estimated from the difference between energies of two levels observed by the Q-DLTS method decrease as the ion fluence is increased. The density of nanocrystals observed by the Q-DLTS method decreases by approximately an order of magnitude as a result of irradiation with fluence of 10{sup 12}-10{sup 13} cm{sup -2} in comparison with an initial unirradiated structure; this decrease is due to formation of conducting chains of nanocrystals in tracks.

36 MATERIALS SCIENCE↗

Features of Defect Formation in Nanostructured Silicon under Ion Irradiation

Nanostructured silicon is irradiated by Si{sup +} and He{sup +} ions with energies of 200 and 150 keV, respectively. Destruction of the structure of irradiated samples and the accumulation of defects at different irradiation fluences are investigated by Raman scattering. It is shown that single-crystal silicon films are amorphized under irradiation at 0.7 displacements per atom. However, at 0.5 displacements per atom, porous silicon does not completely amorphize and the Raman spectra contain a weak signal of the amorphous silicon phase along with a pronounced signal of the crystalline silicon phase. The size of nanocrystals in the structure of porous silicon at different irradiation fluences is estimated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Induced Quasi-Dynamic Disorder in a Structure of Rhenium Ion-Implanted Quartz Glass

The ultraviolet (UV) absorption spectra were studied in UV–Vis–IR quartz glasses exposed to the rhenium ion irradiation at the energy of 30 keV. An increase in ion fluence (5 × 10{sup 15}–5 × 10{sup 17} cm{sup 2}) is found to result in a characteristic fan-shaped broadening of the optical absorption edge of glasses. The results were interpreted in the context of the generalized Urbach rule (the approximation of ion radiation induced quasi-dynamic disorder). The effective radiation disorder cross section of a glass matrix was evaluated from the dose dependence of characteristic Urbach energy. This parameter was found to vary between 1.07 × 10{sup –17}–1.2 × 10{sup –18} cm{sup 2} with increasing fluence. The optical gap width of implanted samples was estimated via the Tautz method for allowed direct interband transitions. The relationship between the second-order deformation potential constants, revealing the correlation between the Urbach energy and the optical gap width in a SiO{sub 2} quartz glass matrix was established using the equivalence principle of static and dynamic structural disorder.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modification of Magnetic Properties of a CoPt Alloy by Ion Irradiation

The effect of ion irradiation on magnetic properties of films of the ferromagnetic CoPt alloy fabricated by electron-beam evaporation has been studied. It is found that the coercive force decreases and the lateral component of the easy-magnetization axis increases as the He{sup +} ion fluence increases from 1 × 10{sup 13} to 1 × 10{sup 16} cm{sup –2}. It is shown by magnetic-force microscopy and the Mandelstam–Brillouin spectroscopy that the formation of isolated circle domains which are magnetic skirmions in the CoPt layer is activated at certain ion-irradiation fluence (3 × 10{sup 14} cm{sup –2}).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterisation of irradiated thin silicon sensors for the CMS phase II pixel upgrade

The high luminosity upgrade of the Large Hadron Collider, foreseen for 2026, necessitates the replacement of the CMS experiment’s silicon tracker. The innermost layer of the new pixel detector will be exposed to severe radiation, corresponding to a 1 MeV neutron equivalent fluence of up to $\Phi _{eq} = 2 \times 10^{16}$ cm$^{-2}$ , and an ionising dose of ${\approx } 5$ MGy after an integrated luminosity of 3000 fb$^{-1}$ . Thin, planar silicon sensors are good candidates for this application, since the degradation of the signal produced by traversing particles is less severe than for thicker devices. In this paper, the results obtained from the characterisation of 100 and 200 $\upmu $ m thick p-bulk pad diodes and strip sensors irradiated up to fluences of $\Phi _{eq} = 1.3 \times 10^{16}$ cm$^{-2}$ are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fusion Nuclear Science Facilities and Pilot Plants Based on the Spherical Tokamak

A Fusion Nuclear Science Facility (FNSF) could play an important role in the development of fusion energy by providing the nuclear environment needed to develop fusion materials and components. The spherical torus/tokamak (ST) is a leading candidate for an FNSF due to its potentially high neutron wall loading and modular configuration. A key consideration for the choice of FNSF configuration is the range of achievable missions as a function of device size. Possible missions include: providing high neutron wall loading and fluence, demonstrating tritium self-sufficiency, and demonstrating electrical self-sufficiency. All of these missions must also be compatible with a viable divertor, first-wall, and blanket solution. ST-FNSF configurations have been developed simultaneously incorporating for the first time: (1) a blanket system capable of tritium breeding ratio TBR approximately 1, (2) a poloidal field coil set supporting high elongation and triangularity for a range of internal inductance and normalized beta values consistent with NSTX/NSTX-U previous/planned operation, (3) a long-legged divertor analogous to the MAST-U divertor which substantially reduces projected peak divertor heat-flux and has all outboard poloidal field coils outside the vacuum chamber and superconducting to reduce power consumption, and (4) a vertical maintenance scheme in which blanket structures and the centerstack can be removed independently. Progress in these ST-FNSF missions vs. configuration studies including dependence on plasma major radius R0 for a range 1m to 2.2m are described. In particular, it is found the threshold major radius for TBR = 1 is R0 greater than or equal to 1.7m, and a smaller R0=1m ST device has TBR approximately 0.9 which is below unity but substantially reduces T consumption relative to not breeding. Calculations of neutral beam heating and current drive for non-inductive ramp-up and sustainment are described. An A=2, R0=3m device incorporating high-temperature superconductor toroidal field coil magnets capable of high neutron fluence and both tritium and electrical self-sufficiency is also presented following systematic aspect ratio studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Benchmarks and Tests of a Multidimensional Cluster Dynamics Model of Helium Implantation in Tungsten

Here, we present a hierarchical multiscale modeling study of implanted helium (He) segregation near grain boundaries (GBs) of tungsten. We extend our spatially dependent cluster dynamics model to two spatial dimensions in order to take into account the biased drift of mobile He clusters toward the GBs observed in atomic-scale simulations. We are also able to reproduce the results from large-scale molecular dynamics simulations near and away from the GBs at low fluence with the extended cluster dynamics model. We suggest and verify that the sink (surface and GB) strengths are attenuated by the increasing concentration of He clusters at high fluence. This cluster dynamics model continues to set the stage for development of fully atomistically informed, coarse-grained models for computationally efficient predictions of He retention and surface morphological evolution, advancing progress toward the goal of efficient and optimal design of plasma-facing components.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method for characterization of repetitive frequency laser resistance of optical coatings

The characterization of repetitive frequency (S-on-1) laser resistance of optical coatings was investigated experimentally based on damage pattern divided into slight damage and severe damage. It was discovered that, when only the slight damage pattern was counted, a peak would be seen in the damage probability curve, and the laser fluence at this peak was stable as pulse sequence S changed. The stable laser fluence at this peak, therefore, could be employed to characterize the repetitive frequency laser resistance of optical coatings. This method is different from the method proposed by the International Organization for Standardization [ISO 11254-2(2001)] and has the advantage of simplicity in practical applications. According to our analysis, it is a method that can obtain the functional damage threshold of optics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exploration of the multiparameter space of nanosecond-laser damage growth in fused silica optics

Historically, the rate at which laser-induced damage sites grow on the exit surface of SiO{sub 2} optics under subsequent illumination with nanosecond-laser pulses of any wavelength was believed to depend solely on laser fluence. We demonstrate here that much of the scatter in previous growth observations was due to additional parameters that were not previously known to affect growth rate, namely the temporal pulse shape and the size of a site. Furthermore, the remaining variability observed in the rate at which sites grow is well described in terms of Weibull statistics. The effects of site size and laser fluence may both be expressed orthogonally in terms of Weibull coefficients. In addition, we employ a clustering algorithm to explore the multiparameter growth space and expose average growth trends. Conversely, this analysis approach also identifies sites likely to exhibit growth rates outside the norm. The ability to identify which sites are likely to grow abnormally fast in advance of the manifestation of such behavior will significantly enhance the accuracy of predictive models over those based on average growth behaviors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhanced laser-induced damage performance of all-glass metasurfaces for energetic pulsed laser applications

To fabricate optical components with surface layers compatible with high power laser applications that may operate as antireflective coatings, polarization rotators, or harness physical anisotropy for other uses, metasurfaces are becoming an appealing candidate. In this study, a large-beam (1.05 cm diameter) 351-nm laser-induced damage testing was done on an all-glass metasurface structure composed of cone-like features with a subwavelength spacing of adjacent features. These structures were fabricated on untreated fused silica glass and damage tested, as were structures that were fabricated on fused silica glass that experienced a preliminary etching process to remove the surface Beilby layer that is characteristic of polished fused silica. The laser-induced damage onset for structures on untreated fused silica glass was 19.3 J∙cm -2 , while the sample that saw an initial pretreatment etch exhibited an improved damage onset of 20.4 J∙cm -2 , only 6% short of the reference pretreated glass damage onset of 21.7 J∙cm -2 . For perspective, the National Ignition Facility (NIF) operational average fluence at this wavelength and pulse length is about 10 J/cm2. At a fluence of 25.5 J∙cm -2 , the reference (pretreated) fused silica initiated 5.2 damage sites per mm 2 , while the antireflective metasurface sample with a preliminary etching process treatment initiated 9.8 damage sites per mm 2 . In conclusion, these findings demonstrate that substrate-engraved metasurfaces are compatible with high energy and power laser applications, further broadening their application space.

36 MATERIALS SCIENCE↗

Effects of repetitive pulsing on multi-kHz planar laser-induced incandescence imaging in laminar and turbulent flames

Planar laser-induced incandescence (LII) imaging is reported at repetition rates up to 100 kHz using a burst-mode laser system to enable studies of soot formation dynamics in highly turbulent flames. Furthermore, to quantify the accuracy and uncertainty of relative soot volume fraction measurements, the temporal evolution of the LII field in laminar and turbulent flames is examined at various laser operating conditions. Under high-speed repetitive probing, it is found that LII signals are sensitive to changes in soot physical characteristics when operating at high laser fluences within the soot vaporization regime. For these laser conditions, strong planar LII signals are observed at measurement rates up to 100 kHz but are primarily useful for qualitative tracking of soot structure dynamics. However, LII signals collected at lower fluences allow sequential planar measurements of the relative soot volume fraction with a sufficient signal-to-noise ratio at repetition rates of 10–50 kHz. Finally, guidelines for identifying and avoiding the onset of repetitive probe effects in the LII signals are discussed, along with other potential sources of measurement error and uncertainty.