Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging

Purpose: The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-ray detector based on a silicon (Si) strip sensor used in an edge-on geometry with an application specific integrated circuit to record the number of x-rays and their energies at high flux and fast frame rates. The investigated detector was integrated with a dedicated breast spectral computed tomography (CT) system to make use of the detector's high spatial and energy resolution and low noise performance under conditions suitable for clinical breast imaging. The aim of this article is to investigate the intrinsic characteristics of the detector, in terms of maximum output count rate, spatial and energy resolution, and noise performance of the imaging system. Methods: The maximum output count rate was obtained with a 50 W x-ray tube with a maximum continuous output of 50 kVp at 1.0 mA. A{sup 109}Cd source, with a characteristic x-ray peak at 22 keV from Ag, was used to measure the energy resolution of the detector. The axial plane modulation transfer function (MTF) was measured using a 67 μm diameter tungsten wire. The two-dimensional (2D) noise power spectrum (NPS) was measured using flat field images and noise equivalent quanta (NEQ) were calculated using the MTF and NPS results. The image quality parameters were studied as a function of various radiation doses and reconstruction filters. The one-dimensional (1D) NPS was used to investigate the effect of electronic noise elimination by varying the minimum energy threshold. Results: A maximum output count rate of 100 million counts per second per square millimeter (cps/mm{sup 2}) has been obtained (1 million cps per 100 × 100 μm pixel). The electrical noise floor was less than 4 keV. The energy resolution measured with the 22 keV photons from a {sup 109}Cd source was less than 9%. A reduction of image noise was shown in all the spatial frequencies in 1D NPS as a result of the elimination of the electronic noise. The spatial resolution was measured just above 5 line pairs per mm (lp/mm) where 10% of MTF corresponded to 5.4 mm{sup −1}. The 2D NPS and NEQ shows a low noise floor and a linear dependence on dose. The reconstruction filter choice affected both of the MTF and NPS results, but had a weak effect on the NEQ. Conclusions: The prototype energy resolved photon counting Si strip detector can offer superior imaging performance for dedicated breast CT as compared to a conventional energy-integrating detector due to its high output count rate, high spatial and energy resolution, and low noise characteristics, which are essential characteristics for spectral breast CT imaging.

60 APPLIED LIFE SCIENCES↗

A method for transferring NASTRAN data between dissimilar computers

The NASTRAN computer program is capable of executing on three different types of computers: (1) the CDC 6000 series, (2) the IBM 360-370 series, and (3) the Univac 1100 series. A typical activity requiring transfer of data between dissimilar computers is the analysis of a large structure such as the space shuttle by substructuring. Models of portions of the vehicle which have been analyzed by subcontractors using their computers must be integrated into a model of the complete structure by the prime contractor on his computer. Presently the transfer of NASTRAN matrices or tables between two different types of computers is accomplished by punched cards or a magnetic tape containing card images. These methods of data transfer do not satisfy the requirements for intercomputer data transfer associated with a substructuring activity. To provide a more satisfactory transfer of data, two new programs, RDUSER and WRTUSER, were created.

Rogers, J. L., Jr.↗

Image data compression having minimum perceptual error

A method for performing image compression that eliminates redundant and invisible image components is described. The image compression uses a Discrete Cosine Transform (DCT) and each DCT coefficient yielded by the transform is quantized by an entry in a quantization matrix which determines the perceived image quality and the bit rate of the image being compressed. The present invention adapts or customizes the quantization matrix to the image being compressed. The quantization matrix comprises visual masking by luminance and contrast techniques and by an error pooling technique all resulting in a minimum perceptual error for any given bit rate, or minimum bit rate for a given perceptual error.

Watson, Andrew B.↗

Homography generation for image registration in inlier-poor domains

A method for efficient image registration between two images in the presence of inlier-poor domains includes receiving a set of candidate correspondences between the two images. An approximate homography between the two images is generated based upon a first correspondence in the correspondences. The set of candidate correspondences is filtered to identify inlier correspondences based upon the approximate homography. A candidate homography is computed based upon the inlier correspondences. The candidate homography can be selected as a final homography between the two images based upon a support of the candidate homography against the set of candidate correspondences. An image registration is performed between the two images based upon the candidate homography being selected as the final homography.

Gonzales, Antonio↗

Solar mirror soiling and heliostat inspection from a mobile imaging system and mobile platform

A system or method for an imaging system is provided for inspecting a heliostat. The imaging system includes a platform and a camera mounted on the platform and a heliostat having a plurality of mirrored facets. The camera is positioned to acquire a first image that serves as a reference image and a second image that is a reflected image from at least one facet. The camera stores image data associated with the first image and the second image, and wirelessly transmits the stored image data to a computing apparatus. The computing apparatus compares the first image with the second image and determines a performance parameter associated with the heliostat.

Yellowhair, Julius↗

Ghost imaging second harmonic generation microscopy

A system and methods for ghost imaging second harmonic generation microscopy. Imaging data is collected in parallel, providing faster imagine reconstruction and enabling reconstruction in scattering environments. Ghost imaging, split light beam interacting with a target and a second light beam unimpeded and not required to pass through the same background. A second harmonic generation image is reconstructed from the detected photons.

Wiederrecht, Gary P.↗

Imaging grain microstructure in a model ceramic energy material with optically generated coherent acoustic phonons

Characterization of microstructure, chemistry and function of advanced energy materials remains a challenge for instrumentation science with tremendous opportunity for new discoveries. This active area of research is starting to make considerable strides with examples ranging from methodologies that employ bright X-rays, electron microscopy and optical spectroscopy. However, further development of instruments, capable of multimodal measurements, is necessary to fully reveal complex microstructure evolution in realistic environments and dynamical systems that are far from equilibrium. In this regard, laser-based instruments have a unique advantage as multiple measurement methodologies are easily combined into a single instrument using standard optics. A new pump-probe method that uses optically generated acoustic phonons is expanding standard optical characterization by providing depth resolved information. Here we report on a noteworthy extension of this pump-probe method to image grain microstructure in ceria. Rich information regarding the orientation of individual crystallites is obtained by monitoring acoustic phonon velocities and noting how the polarization of the probe beam influences the detected signal amplitude. When paired with other optical microscopies, this methodology will provide new perspectives for optical characterization of ceramic materials.

36 MATERIALS SCIENCE↗

SpaceNet 9—Cross-Sensor Alignment of Optical and SAR Imagery

Precise registration of high-resolution synthetic aperture radar (SAR) and optical imagery is necessary for realizing the full potential and benefits of multimodal image analysis. However, two significant challenges presently exist. First, there is a lack of annotated datasets and benchmarks available for high-resolution SAR–optical image registration. Second, an assessment of efficient and reliable image registration methods that can precisely align these modalities is lacking. Here, we present a holistic description of the SpaceNet 9 Challenge and its results. We present a description of the dataset and baseline algorithm along with the results of the challenge, including a description of the winning algorithms. We release the SpaceNet 9 dataset along with open-sourcing the winning algorithms and baseline. The objective of SpaceNet 9 was to compute a dense displacement map that indicates the shift needed to align pixels in an optical image to the pixels in a SAR image. The challenge launched in April 2025 and was active for approximately two months. The top five solutions reduced image alignment error from approximately 34 m to under 13 m for public and private test data, with the best results obtaining a registration error of only 8.5 and 6.7 m on the public testing and private testing dataset, respectively. Usage of pretrained image matching models, robust outlier rejection with RANSAC, and estimating local displacement were common among the top solutions. The results of this challenge provide insight into high-resolution SAR–optical image registration and offer opportunities for future benchmarking in this domain. The baseline algorithm, winning solutions, and datasets are available at https://spacenet.ai/sn9-challenge/.

benchmark datasets↗

Assessing the Need for Preprocedural Laboratory Tests and Stopping Non-steroidal Anti-inflammatory Drugs/Aspirin in Patients Undergoing Percutaneous Bone and Soft Tissue Biopsies

Purpose: Although image-guided biopsies of bone and soft tissue lesions have a low complication rate, there is limited data evaluating use of preprocedural laboratory tests. To address this issue, patients were not required to stop non-steroidal antiinflammatory drugs (NSAIDs) and aspirin or to obtain preprocedural laboratory tests [complete blood count (CBC) and international normalized ratio (INR)], except in special circumstances. The bleeding complication rate, rate of same day biopsies, and the time from when the biopsy was ordered to when it was performed were obtained. Materials and Methods: A total of 332 patients who underwent bone or soft tissue biopsies performed at our institution between 9/1/2017 and 1/9/2019 were prospectively analyzed. These data were compared to a retrospective biopsy cohort of 323 patients between 7/1/2015 and 7/1/2017. Data collected included method of image guidance and bleeding complication rate. The number of days from ordering to performing a biopsy and number of same day biopsies were recorded. Results: There were no bleeding complications in either cohort (OR 1.00, P = 1). The mean time from ordering to performing a bone biopsy was significantly decreased in the prospective group (6.6 days) compared to the retrospective group (8.1 days) (P = 0.012). There were more same day biopsies in the prospective cohort (11.4% vs. 3.4%) (P < 0.001). Conclusions: Preprocedural CBC and INR for bone and soft tissue biopsies can be safely eliminated in most patients. Biopsies performed while patients are taking NSAIDs/aspirin can safely be performed. Adopting revised preprocedural laboratory criteria can result in decreased time to completion of biopsies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Co-orchestration of multiple instruments to uncover structure–property relationships in combinatorial libraries

The rapid growth of automated and autonomous instrumentation brings forth opportunities for the co-orchestration of multimodal tools that are equipped with multiple sequential detection methods or several characterization techniques to explore identical samples. This is exemplified by combinatorial libraries that can be explored in multiple locations via multiple tools simultaneously or downstream characterization in automated synthesis systems. In co-orchestration approaches, information gained in one modality should accelerate the discovery of other modalities. Correspondingly, an orchestrating agent should select the measurement modality based on the anticipated knowledge gain and measurement cost. Herein, we propose and implement a co-orchestration approach for conducting measurements with complex observables, such as spectra or images. The method relies on combining dimensionality reduction by variational autoencoders with representation learning for control over the latent space structure and integration into an iterative workflow via multi-task Gaussian Processes (GPs). This approach further allows for the native incorporation of the system's physics via a probabilistic model as a mean function of the GPs. We illustrate this method for different modes of piezoresponse force microscopy and micro-Raman spectroscopy on a combinatorial Sm-BiFeO3 library. However, the proposed framework is general and can be extended to multiple measurement modalities and arbitrary dimensionality of the measured signals.

47 OTHER INSTRUMENTATION↗

PSF–NET: A Nonparametric Point-spread Function Model for Ground-based Optical Telescopes

Ground-based optical telescopes are seriously affected by atmospheric turbulence induced aberrations. Understanding properties of these aberrations is important both for instrument design and image restoration method development. Because the point-spread function can reflect performance of the whole optic system, it is appropriate to use the point-spread function to describe atmospheric turbulence induced aberrations. Assuming point-spread functions induced by the atmospheric turbulence with the same profile belong to the same manifold space, we propose a nonparametric point-spread function—PSF–NET. The PSF–NET has a cycle convolutional neural network structure and is a statistical representation of the manifold space of PSFs induced by the atmospheric turbulence with the same profile. Testing the PSF–NET with simulated and real observation data, we find that a well trained PSF–NET can restore any short exposure images blurred by atmospheric turbulence with the same profile. Besides, we further use the impulse response of the PSF–NET, which can be viewed as the statistical mean PSF, to analyze interpretation properties of the PSF–NET. We find that variations of statistical mean PSFs are caused by variations of the atmospheric turbulence profile: as the difference of the atmospheric turbulence profile increases, the difference between statistical mean PSFs also increases. The PSF–NET proposed in this paper provides a new way to analyze atmospheric turbulence induced aberrations, which would benefit the development of new observation methods for ground-based optical telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗

Scatter and Blur Corrections for High-Energy X-Ray Radiography

High-energy X-ray radiography is useful as a highly penetrating method for imaging through dense materials. However, the primary modes of interaction of X-rays at these energies involve scattering or the production of secondary high-energy photons, which can interfere with the image. In addition, detector blurring, often resulting from scatter within the detector, can reduce image sharpness. Both of these processes can be mitigated with the use of convolution kernels, with the main challenge being that the proper kernel to use is not known, particularly for the scatter contribution. By radiographing solid slabs of uniform attenuation, we show that point spread functions and material-specific point scatter functions can be determined to significantly reduce the effect of detector blurring and object scatter. Constraining the fits to the slabs and uniform transmission within the slabs is sufficient to recover these functions. A functional form that reproduces the angular distribution of high-energy bremsstrahlung X-rays is presented for recovering point scatter functions. In conclusion, the method is applied to radiographs of objects from bremsstrahlung X-ray sources operating at 4- and 7.5-MV endpoint energies and a significant increase in sharpness is observed.

Blind deconvolution↗

Real time processor for array speckle interferometry

The authors are constructing a real-time processor to acquire image frames, perform array flat-fielding, execute a 64 x 64 element two-dimensional complex FFT (fast Fourier transform) and average the power spectrum, all within the 25 ms coherence time for speckles at near-IR (infrared) wavelength. The processor will be a compact unit controlled by a PC with real-time display and data storage capability. This will provide the ability to optimize observations and obtain results on the telescope rather than waiting several weeks before the data can be analyzed and viewed with offline methods. The image acquisition and processing, design criteria, and processor architecture are described.

Chin, Gordon↗

Megavoltage Computed Tomography Image Guidance With Helical Tomotherapy in Patients With Vertebral Tumors: Analysis of Factors Influencing Interobserver Variability

Purpose: To evaluate megavoltage computed tomography (MVCT)-based image guidance with helical tomotherapy in patients with vertebral tumors by analyzing factors influencing interobserver variability, considered as quality criterion of image guidance. Methods and Materials: Five radiation oncologists retrospectively registered 103 MVCTs in 10 patients to planning kilovoltage CTs by rigid transformations in 4 df. Interobserver variabilities were quantified using the standard deviations (SDs) of the distributions of the correction vector components about the observers' fraction mean. To assess intraobserver variabilities, registrations were repeated after {>=}4 weeks. Residual deviations after setup correction due to uncorrectable rotational errors and elastic deformations were determined at 3 craniocaudal target positions. To differentiate observer-related variations in minimizing these residual deviations across the 3-dimensional MVCT from image resolution effects, 2-dimensional registrations were performed in 30 single transverse and sagittal MVCT slices. Axial and longitudinal MVCT image resolutions were quantified. For comparison, image resolution of kilovoltage cone-beam CTs (CBCTs) and interobserver variability in registrations of 43 CBCTs were determined. Results: Axial MVCT image resolution is 3.9 lp/cm. Longitudinal MVCT resolution amounts to 6.3 mm, assessed as full-width at half-maximum of thin objects in MVCTs with finest pitch. Longitudinal CBCT resolution is better (full-width at half-maximum, 2.5 mm for CBCTs with 1-mm slices). In MVCT registrations, interobserver variability in the craniocaudal direction (SD 1.23 mm) is significantly larger than in the lateral and ventrodorsal directions (SD 0.84 and 0.91 mm, respectively) and significantly larger compared with CBCT alignments (SD 1.04 mm). Intraobserver variabilities are significantly smaller than corresponding interobserver variabilities (variance ratio [VR] 1.8-3.1). Compared with 3-dimensional registrations, 2-dimensional registrations have significantly smaller interobserver variability in the lateral and ventrodorsal directions (VR 3.8 and 2.8, respectively) but not in the craniocaudal direction (VR 0.75). Conclusion: Tomotherapy image guidance precision is affected by image resolution and residual deviations after setup correction. Eliminating the effect of residual deviations yields small interobserver variabilities with submillimeter precision in the axial plane. In contrast, interobserver variability in the craniocaudal direction is dominated by the poorer longitudinal MVCT image resolution. Residual deviations after image guidance exist and need to be considered when dose gradients ultimately achievable with image guided radiation therapy techniques are analyzed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electronic structure orientation as a map of in-plane antiferroelectricity in β'-In 2 Se 3

Antiferroelectric (AFE) materials are excellent candidates for sensors, capacitors, and data storage due to their electrical switchability and high-energy storage capacity. However, imaging the nanoscale landscape of AFE domains is notoriously inaccessible, which has hindered development and intentional tuning of AFE materials. Here, we demonstrate that polarization-dependent photoemission electron microscopy can resolve the arrangement and orientation of in-plane AFE domains on the nanoscale, despite the absence of a net lattice polarization. Through direct determination of electronic transition orientations and analysis of domain boundary constraints, we establish that antiferroelectricity in β'-In 2 Se 3 is a robust property from the scale of tens of nanometers to tens of micrometers. Ultimately, the method for imaging AFE domain organization presented here opens the door to investigations of the influence of domain formation and orientation on charge transport and dynamics.

36 MATERIALS SCIENCE↗

Endophyte-Promoted Phosphorus Solubilization in Populus

Phosphorus is an important plant nutrient, but in soils the majority of phosphorus, present in the form of a phosphate, forms metal complexes in soil making it relatively unavailable to plants. Therefore, inorganic phosphate solubilization is an important process of plant growth promotion by plant associated bacteria and fungi. Non nodulating plant species have been shown to thrive in low-nutrient environments, in some instances by relying on plant associated microorganisms called endophytes. These microorganisms live within the plant and help supply nutrients for the plant. Despite their potential enormous environmental importance, there are a limited number of studies looking at the direct molecular impact of phosphate solubilizing endophytic bacteria on the host plant. In this work, we studied the impact of two endophyte strains of wild poplar (Populus trichocarpa) that solubilize phosphate. Using a combination of x-ray imaging, spectroscopy methods, and proteomics we report direct evidence of endophyte-promoted phosphorus uptake in poplar. We found that the solubilized phosphate inside the plant may react and become insoluble again suggesting that the phosphate could be re-released within the plant by endophytes. Using synchrotron x-ray fluorescence spectromicroscopy combined with x-ray absorption near-edge structure, we visualized the nutrient phosphorus inside poplar roots inoculated by the selected endophytes and found the phosphorus in both forms of organic and inorganic phosphates inside the root. Tomography-based root imaging revealed a markedly different root biomass and root architecture for poplar samples inoculated with the phosphate solubilizing bacteria strains. Proteomics characterization on poplar roots coupled with protein network analysis revealed novel proteins and metabolic pathways with possible involvement in endophyte enriched phosphorus uptake. These findings suggest an important role of endophytes for phosphorus acquisition and provide a deeper understanding of the critical symbiotic associations between poplar and the endophytic bacteria.

36 MATERIALS SCIENCE↗

Calibrating cryogenic temperature of TEM specimens using EELS

Cryogenic Scanning/Transmission Electron Microscopy has been established as a leading method to image sensitive biological samples and is now becoming a powerful tool to understand materials' behavior at low temperatures. However, achieving precise local temperature calibration at low temperatures remains a challenge, which is especially crucial for studying phase transitions and emergent physical properties in quantum materials. In this study, we employ electron energy loss spectroscopy (EELS) to measure local cryogenic specimen temperatures. Here we use the temperature-dependent characteristics of aluminum's bulk plasmon peak in EEL spectra, which shifts due to changes in electron density caused by thermal expansion and contraction. We successfully demonstrate the versatility of this method by calibrating different liquid nitrogen cooling holders in various microscopes, regardless of whether a monochromated or non-monochromated electron beam is used. Temperature discrepancies between the actual temperature and the setpoint temperatures are identified across a range from room temperature to 100 K. This work demonstrates the importance of temperature calibrations at intermediate temperatures and presents a straightforward, robust method for calibrating local temperatures of cryogenically-cooled specimens in electron microscopes.

36 MATERIALS SCIENCE↗

Three-dimensional coherent X-ray diffraction imaging via deep convolutional neural networks

Abstract As a critical component of coherent X-ray diffraction imaging (CDI), phase retrieval has been extensively applied in X-ray structural science to recover the 3D morphological information inside measured particles. Despite meeting all the oversampling requirements of Sayre and Shannon, current phase retrieval approaches still have trouble achieving a unique inversion of experimental data in the presence of noise. Here, we propose to overcome this limitation by incorporating a 3D Machine Learning (ML) model combining (optional) supervised learning with transfer learning. The trained ML model can rapidly provide an immediate result with high accuracy which could benefit real-time experiments, and the predicted result can be further refined with transfer learning. More significantly, the proposed ML model can be used without any prior training to learn the missing phases of an image based on minimization of an appropriate ‘loss function’ alone. We demonstrate significantly improved performance with experimental Bragg CDI data over traditional iterative phase retrieval algorithms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗