Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

A spectrometer for ultrashort gamma-ray pulses with photon energies greater than 10 MeV

Herein we present a design for a pixelated scintillator based gamma-ray spectrometer for non-linear inverse Compton scattering experiments. By colliding a laser wakefield accelerated electron beam with a tightly focused, intense laser pulse, gamma-ray photons up to 100 MeV energies and with few femtosecond duration may be produced. To measure the energy spectrum and angular distribution, a 33 × 47 array of cesium-iodide crystals was oriented such that the 47 crystal length axis was parallel to the gamma-ray beam and the 33 crystal length axis was oriented in the vertical direction. Using an iterative deconvolution method similar to the YOGI code, modeling of the scintillator response using GEANT4 and fitting to a quantum Monte Carlo calculated photon spectrum, we are able to extract the gamma ray spectra generated by the inverse Compton interaction.

47 OTHER INSTRUMENTATION↗

A cryogenic continuously rotating half-wave plate mechanism for the POLARBEAR-2b cosmic microwave background receiver

In this report we present the design and laboratory evaluation of a cryogenic continuously rotating half-wave plate (CHWP) for the POLARBEAR-2b (PB-2b) cosmic microwave background receiver, the second installment of the Simons Array. PB-2b will observe at 5200 m elevation in the Atacama Desert of Chile in two frequency bands centered at 90 GHz and 150 GHz. In order to suppress atmospheric 1/f noise and mitigate systematic effects that arise when differencing orthogonal detectors, PB-2b modulates linear sky polarization using a CHWP rotating at 2 Hz. The CHWP has a 440 mm clear aperture diameter and is cooled to ≈50 K in the PB-2b receiver cryostat. It consists of a low-friction superconducting magnetic bearing and a low-torque synchronous electromagnetic motor, which together dissipate < 2 W. During cooldown, a grip-and-release mechanism centers the rotor to < 0.5 mm, and during continuous rotation, an incremental optical encoder measures the rotor angle with a noise level of 0.1 μrad/Hz. We discuss the experimental requirements for the PB-2b CHWP, the designs of its various subsystems, and the results of its evaluation in the laboratory. The presented CHWP has been deployed to Chile and is expected to see first light on PB-2b in 2020 or 2021.

47 OTHER INSTRUMENTATION↗

SU-E-T-65: Characterization of a 2D Array for QA and Pretreatment Plan Verification

Purpose: The OCTAVIUS detector729 is a 2D array of 729 air vented cubic plane parallel ion chambers used for pretreatment verification and QA. In this study we investigated dosimetric characteristics of this system for clinical photon beam dosimetry. Methods: Detector performance evaluation included determination of the location of the effective point of measurement (EPM), sensitivity, linearity, and reproducibility of detector response, as well as output factor, dose rate, and source to surface distance (SSD) dependence. Finally, assessment of wedge modulated fields was carried out. All the evaluations were performed five times for low and high photon energies. For reference measurements, a 0.6 cc ionization chamber was used. Data analysis and comparison of the OCTAVIUS detector with reference ion chamber data was performed using the VeriSoft patient plan verification software. Results: The reproducibility and stability of the measurements are excellent, the detector showed same signal with a maximum deviation of less than 0.5% in short and long term. Results of sensitivity test showed same signal with a maximum deviation of approximately 0.1%. As the detector 729 response is linear with dose and dose rate, it can be used for the measurement at regions of high dose gradient effectively. The detector agrees with the ionization chamber measurement to within 1% for SSD range of 75 to 125 cm. Also, its measured wedge modulated profiles matched very well with ion chamber dose profiles acquired in a water tank. Conclusions: As the response of the detector 729 is linear with dose and dose rate, it can be used for the measurements in the areas of dose gradients effectively. Based on the measurements and comparisons performed, this system is a reliable and accurate dosimeter for QA and pretreatment plan verification in radiotherapy.

60 APPLIED LIFE SCIENCES↗

WE-D-17A-01: A Dynamic Collimation System for Spot Scanned Proton Therapy: Conceptual Overview

Purpose: In the absence of a collimation system, the lateral penumbra in pencil beam scanning (PBS) proton therapy delivered at low energies is highly dependent on the spot size. This dependence, coupled with the fact that spot sizes increase with decreasing energy, reduces the benefit of the PBS technique for treating shallow tumors such as those found in the head and neck region. In order to overcome this limitation, a dynamic collimation system (DCS) was developed for sharpening the lateral penumbra of low energy proton therapy dose distributions delivered by PBS. Methods: The proposed DCS consists of two pairs of orthogonal trimmer blades which intercept the edges of the proton beam near the target edge in the beam's eye view. Each trimmer blade is capable of rapid motion in the direction perpendicular to the central beam axis by means of a linear motor, with maximum velocity and acceleration of 2.5 m/s and 19.6 m/s{sup 2}, respectively. Two-dimensional treatment plans were created both with and without the DCS for in-air spot sizes (σ-air) of 3, 5, 7, and 9 mm, representing a wide array of clinically available equipment. Results: In its current configuration, the snout of the DCS has outer dimensions of 22.6 × 22.6 cm{sup 2} and is capable of delivering a minimum treatment field size of 15 × 15 cm{sup 2}. Using off the shelf components, the constructed system would weigh less than 20 kg. The treatment plans created with the DCS yielded a reduction in the mean dose to normal tissue surrounding the target of 26.2–40.6% for spot sizes of 3–9 mm, respectively. Conclusion: The DCS can be integrated with current or future proton therapy equipment and we believe it will serve as a useful tool to further improve the next generation of proton therapy delivery.

60 APPLIED LIFE SCIENCES↗

The Nonuniversality of the Frequency Dependence of the Conductivity in Disordered Nanogranulated Systems

The real part of the high-frequency phononless conductivity is calculated in the pair approximation for a disordered array of densely packed spherical nanogranules. The generalization of the theory of phononless conductivity for systems with point impurities to systems with localized finite sizes (arrays of nanogranules or quantum dots) reveals that the high-frequency conductivity depends on the distribution function of the distances between the surfaces of granules P(w). This is expected to cause the discrepancy of the real part of the conductivity σ{sub 1}(ω) from the linear frequency dependence. In the vicinity of the frequency ω ~ ω{sub c} = 2I{sub 0}/ℏ (here I{sub 0} is a preexponential factor of the resonance integral) for disordered granulated systems is likely to deviate from the universality σ{sub 1}(ω) ~ ω{sup s} (s ≈ 1) due to the attenuation of the frequency dependence σ{sub 1}(ω) of the conductivity and its nonmonotonicity. The nonmonotonicity of σ{sub 1}(ω) must arise at lower frequencies as a result of decreased preexponential factor I{sub 0} of the resonance integral with increasing granule size.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Genten: Software for Generalized Tensor Decompositions v. 1.0.0

Tensors, or multidimensional arrays, are a powerful mathematical means of describing multiway data. This software provides computational means for decomposing or approximating a given tensor in terms of smaller tensors of lower dimension, focusing on decomposition of large, sparse tensors. These techniques have applications in many scientific areas, including signal processing, linear algebra, computer vision, numerical analysis, data mining, graph analysis, neuroscience and more. The software is designed to take advantage of parallelism present emerging computer architectures such has multi-core CPUs, many-core accelerators such as the Intel Xeon Phi, and computation-oriented GPUs to enable efficient processing of large tensors.

Phipps, EricT.↗

Wide-Band, Wide-Scan Antenna For Circular Polarization

Circular polarization generated by linearly polarized elements. Basic two-by-two subarray of antenna elements made of microstrip patches. Patches arranged in orthogonal pattern. Fed through different phase shifters so signal at feed points have same orthogonal relationship in phase. Antennas of this general type useful in communications and phased-array radar.

Huang, John↗

The frequency of T Tauri companion stars

We present the results of a magnitude-limited multiplicity survey of T Tauri stars in two nearby star-forming regions, Taurus-Auriga and Ophiuchus-Scorpius. Each of the 69 stars in the sample was observed at K with an infrared array camera on the Hale 5-m Telescope at Palomar Observatory and imaged using 2D speckle imaging techniques. Thirty-three companion stars were found of which 15 were new detections. One of the main results of this survey indicates that the binary star frequency in the projected linear separation range 14 to 225 AU for T Tauri stars is a factor of 3.5 greater than that of the solar-type main-sequence stars. Given the limited angular separation range of this survey, the rate at which binaries are detected suggests that most T Tauri stars have companions. We propose that the observed overabundance of companions to T Tauri stars relative to their older counterparts on the main sequence is an evolutionary effect; in this scheme, triple and higher order T Tauri star systems, which are observed at higher frequencies than for the solar-type main-sequence stars, are disrupted by close encounters with another star or system of stars.

Ghez, A. M.↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Electron-Beam-Induced Molecular Plasmon Excitation and Energy Transfer in Silver Molecular Nanowires

In this work, we investigate (1) electron-beam-induced plasmon absorption spectra of Ag molecular nanowire dimers and (2) electron-beam-induced energy transfer between two nanowires. We employ linear-response time-dependent density functional theory (TDDFT) and real-time TDDFT methods to simulate the electron-beam-induced plasmonic excitations, dynamics, and corresponding electron energy loss spectrum for small models of a single molecular nanowire with four Ag atoms and for two Ag nanowires. An array of different relative orientations of nanowires and of different initial excitation conditions resulting from applying an electron beam at different positions with respect to the Ag nanowires is investigated. The results demonstrate (1) an electron beam can induce plasmonic excitations from the molecular Ag nanowire ground state to the excited states that are both optically allowed and forbidden, (2) a tunability for selective excitations that can be controlled by the position of a focused electron beam, and (3) kinetic and dynamic behaviors of time-dependent electron-beam-induced energy transfer between two Ag molecular nanowires depend on the position of the beam source and nanowire separation distance, providing insights into the spatial dependences of plasmonic couplings in nanowire arrays.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct writing of continuous and discontinuous sub-wavelength periodic surface structures on single-crystalline silicon using femtosecond laser

Laser-induced ripples or uniform arrays of continuous near sub-wavelength or discontinuous deep sub-wavelength structures are formed on single-crystalline silicon (Si) by femtosecond (fs) laser direct writing technique. Laser irradiation was performed on Si wafers at normal incidence in air and by immersing them in dimethyl sulfoxide using linearly polarized Ti:sapphire fs laser pulses of ∼110 fs pulse duration and ∼800 nm wavelength. Morphology studies of laser written surfaces reveal that sub-wavelength features are oriented perpendicular to laser polarization, while their morphology and spatial periodicity depend on the surrounding dielectric medium. The formation mechanism of the sub-wavelength features is explained by interference of incident laser with surface plasmon polaritons. This work proves the feasibility of fs laser direct writing technique for the fabrication of sub-wavelength features, which could help in fabrication of advanced electro-optic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SMM J04135+10277: A CANDIDATE EARLY-STAGE ''WET-DRY'' MERGER OF TWO MASSIVE GALAXIES AT z = 2.8

We report interferometric imaging of CO(J = 3{yields}2) emission toward the z = 2.846 submillimeter-selected galaxy SMM J04135+10277, using the Combined Array for Research in Millimeter-wave Astronomy (CARMA). SMM J04135+10277 was previously thought to be a gas-rich, submillimeter-selected quasar, with the highest molecular gas mass among high-z quasars reported in the literature. Our maps at {approx}6 Multiplication-Sign improved linear resolution relative to earlier observations spatially resolve the emission on {approx}1.''7 scales, corresponding to a (lensing-corrected) source radius of {approx}5.2 kpc. They also reveal that the molecular gas reservoir, and thus, likely the submillimeter emission, is not associated with the host galaxy of the quasar, but with an optically faint gas-rich galaxy at 5.''2, or 41.5 kpc projected distance from the active galactic nucleus (AGN). The obscured gas-rich galaxy has a dynamical mass of M{sub dyn} sin{sup 2} i = 5.6 Multiplication-Sign 10{sup 11} M{sub Sun }, corresponding to a gas mass fraction of {approx_equal}21%. Assuming a typical M{sub BH}/M{sub *} ratio for z {approx}> 2 quasars, the two galaxies in this system have an approximate mass ratio of {approx}1.9. Our findings suggest that this quasar-starburst galaxy pair could represent an early stage of a rare major, gas-rich/gas-poor ({sup w}et-dry{sup )} merger of two massive galaxies at z = 2.8, rather than a single, gas-rich AGN host galaxy. Such systems could play an important role in the early buildup of present-day massive galaxies through a submillimeter-luminous starburst phase, and may remain hidden in larger numbers among rest-frame far-infrared-selected quasar samples at low and high redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

3- to 13-micron spectra of Io

The Broadband Array Spectrograph System with the NASA Infrared Telescope Facility was used to obtain 3- to 13-micron spectra of Io on June 14-16, 1991. The extinction correction and its error for each standard star (Alpha Boo, Alpha Lyr, and Mu UMa) were found individually by performing an unweighted linear fit of instrumental magnitude as a function of airmass. The model results indicate two significant trends: (1) modest differences between the two hemispheres at lower background temperatures and (2) a tendency to higher temperatures, smaller areas, and less power from the warm component at higher background temperatures with an increased contrast between the two hemispheres. The increased flux from 8 to 13 microns is due primarily to a greater area on the Loki (trailing) hemisphere for the warm component, although temperature also plays a role.

Noll, Keith S.↗

CFD Simulation of an Inward-Turning Supersonic Inlet Unstart at Flight Mach Number 1.7

Interest in inward-turning supersonic inlets renewed during NASA’s Commercial Supersonic Technology Project, as a means of reducing disturbances caused by propulsion integration. Inward-turning designs have the potential to greatly reduce the strength of shock waves emanating outward from the nacelle, and therefore their contribution to the overall sonic boom signature. For top-mounted, or over-wing installations, disturbances to aircraft aerodynamics are reduced. The nature of the inward-turning geometry results in a boundary-layer thickening effect, opposite that of the familiar thinning of an outward-turning cone boundary-layer. The application of a small amount of boundary-layer bleed at the throat has been shown to alleviate the negative effects of the boundary-layer on subsonic diffuser performance. Boundary-layer bleed, however, comes at the expense of increased complexity, and external disturbances at bleed exits that would partially defeat the purpose of the inward-turning scheme. Vortex generators were proposed as an alternative to bleed, and an initial CFD study of their effectiveness in this application forms the basis of the present work. A source-term model in the Wind-US CFD code was used to model the effects of an array of vortex generators placed at the entrance to the subsonic diffuser. Baseline results with no vortex generators compared favorably to previously reported results with no bleed at back-pressures near the design point, but stability margin in the present case was limited by a curious non-linear phenomena similar to unstart in mixed-compression inlets. While some improvement was noted with vortex generators, their effectiveness was diminished by the limited stability margin. A time-accurate calculation was subsequently performed to better understand this process. Results of this calculation are presented and instantaneous solutions compared with steady-state, subcritical results previously reported. The stability margin limitation is attributed to the use of a constant-pressure outflow boundary condition, which differed from that used in the prior simulations.

Pre-Compressor Cooling, Water Injection, Hypersoni↗

Driving magnetic turbulence using flux ropes in a moderate guide field linear system

We present a series of experiments on novel, line-tied plasma geometries as a study of the generation of chaos and turbulence in line-tied systems. Plasma production and the injection scale for magnetic energy is provided by spatially discrete plasma guns that inject both plasma and current. The guns represent a technique for controlling the injection scale of magnetic energy. A two-dimensional (2-D) array of magnetic probes provides spatially resolved time histories of the magnetic fluctuations at a single cross-section of the experimental cylinder, allowing simultaneous spatial measurements of chaotic and turbulent behaviour. The first experiment shows chaotic fluctuations and self-organization in a hollow-current line-tied screw pinch. These dynamics is modulated primarily by the applied magnetic field and weakly by the plasma current and safety factor. The second experiment analyses the interactions of multiple line-tied flux ropes. The flux ropes all exhibit chaotic behaviour, and under certain conditions develop an inverse cascade to larger scales and a turbulent inertial range with magnetic energy ( $E$ ) related to perpendicular wave number ( $k_{\bot }$ ) as $E\propto k_{\bot }^{-2.5\pm 0.5}$ .

Physics↗

Non-enzymatic glucose detection using magnetic nanoemulsions

We probe the optical properties and intermolecular interactions in magnetically responsive nanoemulsions in the presence of glucose. The equilibrium interdroplet distance between the emulsion droplets in an one-dimensional array increases by several nanometers in the presence of glucose because of intermolecular hydrogen bonding with sodium dodecyl sulphate molecules at the oil-water interface that gives rise to stretched lamellae-like structure. The observed large red shift in the diffracted Bragg peak (∼50–100 nm) and the linear response in the glucose concentration range of 0.25–25 mM offer a simple, fast, and cost effective non-enzymatic approach for glucose detection.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THE OUTBURST OF THE BLAZAR S5 0716+71 IN 2011 OCTOBER: SHOCK IN A HELICAL JET

We present the results of optical (R band) photometric and polarimetric monitoring and Very Long Baseline Array (VLBA) imaging of the blazar S5 0716+714 along with Fermi {gamma}-ray data during a multi-waveband outburst in 2011 October. We analyze total and polarized intensity images of the blazar obtained with the VLBA at 43 GHz during and after the outburst. Monotonic rotation of the linear polarization vector at a rate of {approx}> 50 Degree-Sign per night coincided with a sharp maximum in {gamma}-ray and optical flux. At the same time, within the uncertainties, a new superluminal knot appeared with an apparent speed of 21 {+-} 2c. The general multi-frequency behavior of the outburst can be explained within the framework of a shock wave propagating along a helical path in the blazar's jet.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-434: Development of a Fan-Beam Optical Scanner Using CMOS Array for Small Field Dosimetry

Purpose: To design and construct a second generation optical computed tomography (OCT) system using a fan-beam with a CMOS array detector for the 3D dosimetry with polymer gel and radiochromic solid dosimeters. The system was specifically designed for the small field dosimetry. Methods: The optical scanner used a fan-beam laser, which was produced from a collimated red laser beam (λ=620 nm) with a 15-degree laser-line generating lens. The fan-beam was sent through an index-matching bath which holds the sample stage and a sample. The emerging laser light was detected with a 2.54 cm-long CMOS array detector (512 elements). The sample stage rotated through the full 360 degree projection angles at 0.9-degree increments. Each projection was normalized to the unirradiated sample at the projection angle to correct for imperfections in the dosimeter. A larger sample could be scanned by using a motorized mirror and linearly translating the CMOS detector. The height of the sample stage was varied for a full 3D scanning. The image acquisition and motor motion was controlled by a computer. The 3D image reconstruction was accomplished by a fan-beam reconstruction algorithm. All the software was developed inhouse with MATLAB. Results: The scanner was used on both PRESAGE and PAGAT gel dosimeters. Irreconcilable refraction errors were seen with PAGAT because the fan beam laser line refracted away from the detector when the field was highly varying in 3D. With PRESAGE, this type of error was not seen. Conclusion: We could acquire tomographic images of dose distributions by the new OCT system with both polymer gel and radiochromic solid dosimeters. Preliminary results showed that the system was more suited for radiochromic solid dosimeters since the radiochromic dosimeters exhibited minimal refraction and scattering errors. We are currently working on improving the image quality by thorough characterization of the OCT system.

60 APPLIED LIFE SCIENCES↗