Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Blade tip clearance measurement of the turbine engines based on a multi-mode fiber coupled laser ranging system

The blade tip clearance is a parameter of great importance to guarantee the efficiency and safety of the turbine engines. In this article, a laser ranging system designed for blade tip clearance measurement is presented. Multi-mode fiber is utilized for optical transmission to guarantee that enough optical power is received by the sensor probe. The model of the tiny sensor probe is presented. The error brought by the optical path difference of different modes of the fiber is estimated and the length of the fiber is limited to reduce this error. The measurement range in which the optical power received by the probe remains essentially unchanged is analyzed. Calibration experiments and dynamic experiments are conducted. The results of the calibration experiments indicate that the resolution of the system is about 0.02 mm and the range of the system is about 9 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a Three-Layer Impactor for Material Strength Measurements at Multi-Megabar Pressures

Off-Hugoniot loading methods for dynamic compression have been a topic of interest for many years as a means of accessing high pressures without melting a material. Simulations and an initial test experiment of a three-layer gas-gun impactor suitable for use in measuring dynamic material strength at multi-megabar pressures are described. As shown through ARES hydrocode simulations, an impactor consisting of a low-, medium-, and high-impedance material, such as TPX, Al, and Ta or Pt, can produce a quasi-isentropic loading path up to 4.6 Mbar pressure with a low homologous temperature (T/T melt = 0.1–0.25). These impactors can also be tailored to create a pressure drive suitable for a Lagrangian sound speed experiment. Simulated in-situ velocities were analyzed to determine the change in calculated strength due to non-uniformity in the impactor, which provides a measure of error sensitivity. An initial test of a three-layer projectile onto a flat target at 4.4 km/s impact velocity is reported. Finally, while the impactor incurred some delamination during firing, the measured sample/window interface velocity generally agrees with the simulated peak velocity and subsequent release, indicating the feasibility of this approach for measuring material strength.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Estimation of Lower-Body Kinetics from Loading Profile and Kinematics Alone, Without Measured Ground Reaction Forces

Biomechanical models of human motion can estimate kinetic outcomes, such as joint moments, joint forces and muscle forces. Typically, one performs an inverse dynamics (ID) analysis to compute joint moments from joint angles and measured external forces. Sometimes it is impractical to measure ground reaction forces and moments (GRF&M). We devised an empirical method for performing ID analysis of resistance exercises without measured GRF&M. The method solves the multibody dynamics equations of motion with four key assumptions about the GRF&M that reduce the number of unknowns. The assumptions are 1) negligible ground reaction moments, 2) fixed lateral/medial location of the center of pressure (COP), 3) equal fore/aft location of the COP between the feet, and 4) constant angle of the GRF vector relative to the vertical axis in the frontal plane. We used evaluation trials from a spaceflight countermeasure resistance training device to test this approach. Four participants performed squat and deadlift exercises at various loads. We compared results from traditional ID analysis to results without measured GRF&M using our method. We found that joint moment trajectories in the sagittal plane were qualitatively similar in shape between the two methods, and the amount of root mean squared error (RMSE), measured by difference in joint moment impulse, was typically under 10 percent. Non-sagittal joint moment trajectories, which are much lower in overall magnitude, were not qualitatively similar in shape between the two methods. Non-sagittal moments displayed much higher RMSE, with typical values well over 50 percent. These findings were further supported by validation metrics (Sprague and Geers' P and M metrics, Pearson's r correlation coefficient). Based on these findings, we concluded that useful kinetic results are obtained from ID analysis of squat and deadlift exercises, even when GRF&M are not measured, as long as the outcomes of interest lie in the sagittal plane.

computational modeling↗

Further evaluation of the constrained least squares electromagnetic compensation method

Technologies exist for construction of antennas with adaptive surfaces that can compensate for many of the larger distortions caused by thermal and gravitational forces. However, as the frequency and size of reflectors increase, the subtle surface errors become significant and degrade the overall electromagnetic performance. Electromagnetic (EM) compensation through an adaptive feed array offers means for mitigation of surface distortion effects. Implementation of EM compensation is investigated with the measured surface errors of the NASA 15 meter hoop/column reflector antenna. Computer simulations are presented for: (1) a hybrid EM compensation technique, and (2) evaluating the performance of a given EM compensation method when implemented with discretized weights.

Smith, William T.↗

Performance of Al-Mn Transition-Edge Sensor Bolometers in SPT-3G

SPT-3G is a polarization-sensitive receiver, installed on the South Pole Telescope, that measures the anisotropy of the cosmic microwave background (CMB) from degree to arcminute scales. The receiver consists of ten 150-mm-diameter detector wafers, containing a total of similar to 16,000transition-edge sensor (TES) bolometers observing at 95, 150, and 220 GHz. During the 2018-2019 austral summer, one of these detector wafers was replaced by a new wafer fabricated with Al-Mn TESs instead of the Ti/Au design originally deployed for SPT-3G. We present the results of in-laboratory characterization and on-sky performance of this Al-Mn wafer, including electrical and thermal properties, optical efficiency measurements, and noise-equivalent temperature. In addition, we discuss and account for several calibration-related systematic errors that affect measurements made using frequency-domain multiplexing readout electronics.

Al-Mn↗

Directions of Moving Plaids is Biased by Asymmetric Viewing Windows

Directionally selective V1 neurons are tuned to particular spatio-temporal frequencies and respond to local 1-D edge motion. At least some MT neurons however appear to respond to the actual velocity of moving 2D patterns. To better understand how the 1D local motion information available from VI is integrated to derive a 2D velocity signal we investigated human perception of moving plaids, 2-D patterns composed of the sum of two 1-D sinusoidal gratings of different orientations. We measured the effect of the shape of the viewing window on the perceived direction of plaid motion. The plaids were spatially windowed by 2-D Gaussians with unequal standard deviations (sigma 1, sigma 2). Four observers indicated perceived direction by adjusting a pointer. Direction errors were measured as a function of the difference between window orientation and true plaid direction (DELTA THETA) for several grating spatial frequencies (SF = 0.3, 0.6, 1.2 c/d) and window aspect ratios (AR = sigma 1/sigma 2 = 1, 1.4, 2, 4). Observers showed systematic errors in perceived direction (approx. 15 for AR = 4 and SF = 0.6 c/d) that peaked at DELTA THETA approx. 40. The errors increased for increasing aspect ratio and decreased for increasing spatial frequencies (or number of cycles). These results show that despite the unambiguous motion of the plaids, under these conditions human misperceive the motion. These data constrain models of motion integration from V1 to MT and, in particular, are inconsistent with algorithms that use either the Intersection of Constraints rule or cross correlation to compute the perceived direction of motion.

Beutter, B. R.↗

Direction of Moving Plaids is Biased by Asymmetric Viewing Windows

Directionally selective V1 neurons are tuned to particular spatiotemporal frequencies and respond to local 1-D edge motion. At least some MT neurons however appear to respond to the actual velocity of moving 2D patterns (Movshon et al., EBR, 11:117, 1986). To better understand how the 1D local motion information available from V1 is integrated to derive a 2D velocity signal we investigated human perception of moving plaids, 2-D patterns composed of the sum of two 1-D sinusoidal gratings of different orientations. We measured the effect of the shape of the viewing window on the perceived direction of plaid motion. The plaids were spatially windowed by 2-D Gaussians with unequal standard deviations (sigma l, sigma 2). Four observers indicated perceived direction by adjusting a pointer. Direction errors were measured as a function of the difference between window orientation and true plaid direction (delta theta) for several grating spatial frequencies (SF = 0.3, 0.6, 1.2 c/d) and window aspect ratios (AR = sigma 1/sigma 2 = 1, 1.4, 2,4). Observers showed systematic errors in perceived direction (approx. 15 degrees for R = 4 and SF = 0.6 c/d) that peaked at delta theta approximately 40 degrees. The errors increased for increasing aspect ratio and decreased for increasing spatial frequencies (or number of cycles). These results show that despite the unambiguous motion of the plaids, within asymmetric windows, human can systematically misperceive plaid direction. These data constrain models of motion integration within extrastriate cortex and, in particular, are inconsistent with algorithms that use either the Intersection of Constraints rule or cross correlation to compute velocity.

Beutter, Brent Robert↗

Ultra-Light Precision Membrane Optics

SRS Technologies and NASA Marshall Space Flight Center have conducted a research effort to explore the possibility of developing ultra-lightweight membrane optics for future imaging applications. High precision optical flats and spherical mirrors were produced under this research effort. The thin film mirrors were manufactured using surface replication casting of CPI(Trademark), a polyimide material developed specifically for UV hardness and thermal stability. In the course of this program, numerous polyimide films were cast with surface finishes better than 1.5 nanometers rms and thickness variation of less than 63 nanometers. Precision membrane optical flats were manufactured demonstrating better than 1/13 wave figure error when measured at 633 nanometers. The aerial density of these films is 0.037 kilograms per square meter. Several 0.5-meter spherical mirrors were also manufactured. These mirrors had excellent surface finish (1.5 nanometers rms) and figure error on the order of tens of microns. This places their figure error within the demonstrated correctability of advanced wavefront correction technologies such as real time holography.

Moore, Jim↗

PHOTOMETRIC REDSHIFT PROBABILITY DISTRIBUTIONS FOR GALAXIES IN THE SDSS DR8

We present redshift probability distributions for galaxies in the Sloan Digital Sky Survey (SDSS) Data Release 8 imaging data. We used the nearest-neighbor weighting algorithm to derive the ensemble redshift distribution N(z), and individual redshift probability distributions P(z) for galaxies with r < 21.8 and u < 29.0. As part of this technique, we calculated weights for a set of training galaxies with known redshifts such that their density distribution in five-dimensional color-magnitude space was proportional to that of the photometry-only sample, producing a nearly fair sample in that space. We estimated the ensemble N(z) of the photometric sample by constructing a weighted histogram of the training-set redshifts. We derived P(z)'s for individual objects by using training-set objects from the local color-magnitude space around each photometric object. Using the P(z) for each galaxy can reduce the statistical error in measurements that depend on the redshifts of individual galaxies. The spectroscopic training sample is substantially larger than that used for the DR7 release. The newly added PRIMUS catalog is now the most important training set used in this analysis by a wide margin. We expect the primary sources of error in the N(z) reconstruction to be sample variance and spectroscopic failures: The training sets are drawn from relatively small volumes of space, and some samples have large incompleteness. Using simulations we estimated the uncertainty in N(z) due to sample variance at a given redshift to be {approx}10%-15%. The uncertainty on calculations incorporating N(z) or P(z) depends on how they are used; we discuss the case of weak lensing measurements. The P(z) catalog is publicly available from the SDSS Web site.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum process reconstruction based on mutually unbiased basis

We study a quantum process reconstruction based on the use of mutually unbiased projectors (MUB projectors) as input states for a D-dimensional quantum system, with D being a power of a prime number. This approach connects the results of quantum-state tomography using mutually unbiased bases with the coefficients of a quantum process, expanded in terms of MUB projectors. We also study the performance of the reconstruction scheme against random errors when measuring probabilities at the MUB projectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of Spatial Discretization Methods for Solving the S N Equations Using a Three-Dimensional Method of Manufactured Solutions Benchmark Suite with Escalating Order of Nonsmoothness

For this study, a comparison of the accuracy and computational efficiency of spatial discretization methods of the three-dimensional S N equations is conducted, including discontinuous Galerkin finite element methods, the arbitrarily high-order transport method of nodal type (AHOTN), the linear-linear method, the linear-nodal (LN) method, and the higher-order diamond difference method. For this purpose, we have developed a suite of method of manufactured solutions benchmarks that provides an exact solution of the S N equations even in the presence of scattering. Most importantly, our benchmark suite permits the user to set an arbitrary level of smoothness of the exact solution across the singular characteristics. Our study focuses on the computational efficiency of the considered spatial discretization methods. Numerical results indicate that the best-performing method depends on the norm used to measure the discretization error. We employ discrete Lp norms and integral error norms in this work. For configurations with continuous exact angular flux, high-order AHOTNs perform best under L p error norms, while the LN method performs best when measured by integral error norms. Lastly, when the angular flux is discontinuous, a new singular-characteristic tracking method for three-dimensional geometries performs best among the considered methods.

97 MATHEMATICS AND COMPUTING↗

Spectral Line Profile Analysis Using Higher Diffraction Order in Vacuum Ultraviolet Region

Using a one meter VUV spectrometer and a MCP coupled to a CCD detector on TCABR tokamak, ion temperatures from impurity species have been measured and much better spectral resolution was obtained using higher order diffraction lines. Due to very small Doppler effect in the VUV region compared to large instrumental broadening, ion temperatures obtained from first order diffraction present large errors. The use of second, third and fourth order diffraction emissions increases the line broadening and results in lower error temperature measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Visual Scanning Hartmann Optical Tester (VSHOT) Uncertainty Analysis (Milestone Report)

In 1997, an uncertainty analysis was conducted of the Video Scanning Hartmann Optical Tester (VSHOT). In 2010, we have completed a new analysis, based primarily on the geometric optics of the system, and it shows sensitivities to various design and operational parameters. We discuss sources of error with measuring devices, instrument calibrations, and operator measurements for a parabolic troughmirror panel test. These help to guide the operator in proper setup, and help end-users to understand the data they are provided. We include both the systematic (bias) and random (precision) errors for VSHOT testing and their contributions to the uncertainty. The contributing factors we considered in this study are: target tilt; target face to laser output distance; instrument vertical offset;laser output angle; distance between the tool and the test piece; camera calibration; and laser scanner. These contributing factors were applied to the calculated slope error, focal length, and test article tilt that are generated by the VSHOT data processing. Results show the estimated 2-sigma uncertainty in slope error for a parabolic trough line scan test to be +/-0.2 milliradians;uncertainty in the focal length is +/- 0.1 mm, and the uncertainty in test article tilt is +/- 0.04 milliradians.

14 SOLAR ENERGY↗

The effect of sensor and actuator errors on static shape control for large space structures

An analytical study was performed to predict and assess the effect of actuator and sensor errors on the performance of a shape control procedure for flexible space structures using applied temperatures. Approximate formulas were derived for the expected value and variance of the rms distortion ratio (ratio of rms distortions with and without corrections) based on the assumption of zero-mean normally distributed random errors in measured distortions and actuator output temperatures. Studies were carried out for a 55-meter radiometer antenna reflector distorted from its ideal parabolic shape by nonuniform orbital heating. The first study consisted of varying the sensor and actuator errors for the case of 12 actuators and computing the distortion ratio. In the second study, sensor and actuator errors were prescribed and the effect of increasing the number of actuators was evaluated.

Haftka, R. T.↗

Effect of sensor and actuator errors on static shape control for large space structures

An analytical study was performed to predict and assess the effect of actuator and sensor errors on the performance of a shape control procedure for flexible space structures using applied temperatures. Approximate formulas were derived for the expected value and variance of the rms distortion ratio (ratio of rms distortions with and without corrections) based on the assumption of zero-mean normally distributed random errors in measured distortions and actuator output temperatures. Studies were carried out for a 55-meter radiometer antenna reflector distorted from its ideal parabolic shape by nonuniform orbital heating. The first study consisted of varying the sensor and actuator errors for the case of 12 actuators and computing the distortion ratio. In the second study, sensor and actuator errors were prescribed and the effect of increasing the number of actuators was evaluated.

Haftka, Raphael T.↗

T1 VSAT Fade Compensation Statistical Results

New satellite communication systems are steadily seeking to use higher frequency bands to accommodate the requirements for additional capacity. At these higher frequencies, propagation impairments that did not significantly affect the signal at lower frequencies begin to have considerable impact. In Ka-band. the next logical commercial frequency band to be used for satellite communication, attenuation of the signal due to rain is a primary concern. An experimental satellite built by NASA, the Advanced Communication Technology Satellite (ACTS). launched in September 1993, is the first U.S. communication satellite operating in the Ka-band. In addition to higher carrier frequencies, a number of other new technologies, including on-board baseband processing. multiple beam antennas, and rain fade detection and compensation techniques, were designed into the ACTS. Verification experiments have been conducted since the launch to characterize the new technologies. The focus of this paper is to characterize the method used by the ACTS TI Very Small Aperture Terminal (TI VSAT) ground stations in detecting the presence of fade in the communication signal and to adaptively compensate for it by the addition of burst rate reduction and forward error correction. Measured data obtained from the ACTS program was used to validate the compensation technique. A software process was developed and demonstrated to statistically characterize the increased availability achieved by the compensation techniques in terms of the bit error rate time enhancement factor. Several improvements to the ACTS technique are discussed and possible implementations for future Ka band system are offered.

Johnson, Sandra K.↗

Single-shot quantum error correction in intertwined toric codes

We construct a subsystem code in three dimensions that exhibits single-shot error correction in a user-friendly and transparent way. As this code is a subsystem version of coupled toric codes, we call it the intertwined toric code (ITC). Although previous codes share the property of single-shot error correction, the ITC is distinguished by its physically motivated origin, geometrically straightforward logical operators and errors, and a simple phase diagram. The code arises from three-dimensional (3D) stabilizer toric codes in a way that emphasizes the physical origin of the single-shot property. In particular, starting with two copies of the 3D toric code, we add check operators that provide for the confinement of pointlike excitations without condensing the loop excitations. Geometrically, the bare and dressed logical operators in the ITC derive from logical operators in the underlying toric codes, creating a clear relationship between errors and measurement outcomes. The syndromes of the ITC resemble the syndromes of the single-shot code by Kubica and Vasmer, allowing us to use their decoding schemes. We also extract the phase diagram corresponding to ITC and show that it contains the phases found in the Kubica-Vasmer code. Lastly, we suggest various connections to Walker-Wang models and measurement-based quantum computation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Refinement of Treatment Setup and Target Localization Accuracy Using Three-Dimensional Cone-Beam Computed Tomography for Stereotactic Body Radiotherapy

Purposes: To quantitatively compare two-dimensional (2D) orthogonal kV with three-dimensional (3D) cone-beam CT (CBCT) for target localization; and to assess intrafraction motion with kV images in patients undergoing stereotactic body radiotherapy (SBRT). Methods and Materials: A total of 50 patients with 58 lesions received 178 fractions of SBRT. After clinical setup using in-room lasers and skin/cradle marks placed at simulation, patients were imaged and repositioned according to orthogonal kV/MV registration of bony landmarks to digitally reconstructed radiographs from the planning CT. A subsequent CBCT was registered to the planning CT using soft tissue information, and the resultant 'residual error' was measured and corrected before treatment. Posttreatment 2D kV and/or 3D CBCT images were compared with pretreatment images to determine any intrafractional position changes. Absolute averages, statistical means, standard deviations, and root mean square (RMS) values of observed setup error were calculated. Results: After initial setup to external marks with laser guidance, 2D kV images revealed vector mean setup deviations of 0.67 cm (RMS). Cone-beam CT detected residual setup deviations of 0.41 cm (RMS). Posttreatment imaging demonstrated intrafractional variations of 0.15 cm (RMS). The individual shifts in three standard orthogonal planes showed no obvious directional biases. Conclusions: After localization based on superficial markings in patients undergoing SBRT, orthogonal kV imaging detects setup variations of approximately 3 to 4 mm in each direction. Cone-beam CT detects residual setup variations of approximately 2 to 3 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗