Search NASA⌕ Search

SEARCH · Search NASA

Results for “module performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Development of a Flexible Design for Irradiation of Miniature Tensile and Charpy Test Specimens in the High Flux Isotope Reactor

Fusion promises a sustainable, clean, safe source of energy that could play a major role in solving the great challenge of meeting the world’s growing power needs. Much of fusion technology in its current state requires further maturation to support a usable fusion reactor platform. Given that the environment in and around a sustained fusion reaction is very harsh, selecting the best materials for such a reactor is crucial. The European fusion materials community spent many years developing one such material, a low-activation martensitic structural steel named Eurofer that is intended primarily for use in the fusion blanket modules. Although this material has reached technological maturity, nuclear performance data are required to qualify Eurofer for these applications. Karlsruhe Institute of Technology (KIT), a member of the EUROfusion consortium, has sponsored an irradiation program to establish irradiation performance data for various forms of the Eurofer alloy family. This document describes the design and development of flexible irradiation capsule designs that can be used to irradiate specimens to temperatures ranging from ~200 – 400°C. This report also details as-built data for the screening and high dose phases of the KIT irradiation campaign of capsules that were submitted for irradiation in the High Flux Isotope Reactor in FY18.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Captain Electronics Technical Report

This report details the current layout of the electronics for the mini-CAPTAIN detector system, as well as the lessons learned during commissioning. We will present some electronics suggestions for future LArTPC systems. Mini-CAPTAIN is one of three detectors used in the Cryogenic Apparatus for Precision Tests of Argon Interactions with Neutrino (CAPTAIN) project at Los Alamos National Lab (LANL). The detector uses many of the same electronic components as current and developing LArTPC experiments. This includes the motherboards, service cards, amplifiers and ADC made by Brookhaven National Laboratory (BNL) and the front-end modules (FEM) made by Nevis Labs. The cold electronics performed well in both vacuum and cryogenic environments after months of exposure. Mini-CAPTAIN was tested with two liquid nitrogen and three liquid argon run cycles. The final testing was performed at the Weapons Neutron Research (WNR) facility at LANSCE. Mini-CAPTAIN was able to maintain a clean electrical signal through most of the test cycles. Most noise reduction was achieved with power source filtering and careful attention to the ground configuration. Direct oscilloscope probing on the front-end output provided the fastest analysis and correction of noise sources. Ground path assumptions and integrity were verified with frequent impedance checks. A high voltage break down event damaged some of the channels on the motherboards and a number of the wire decoupling capacitors. This temporarily introduced significant noise on the wire planes due to current leakage. The detector was taken apart and reassembled three times, with successful noise reduction after each activity. The current raw signal-to-noise ratio is 9 to 1.

42 ENGINEERING↗

Tough Errors are no Match (TEAM): Optimizing the Quantum Compiler for Noise Resilience

This project builds toward a comprehensive error-mitigating toolkit that makes quantum programming more robust and adaptive to the noisy, resource-limited nature of today’s quantum hardware. To that end, it integrates established error-mitigation methods — such as zero-noise extrapolation and dynamical decoupling — directly into compiler infrastructures. These techniques will be packaged as modules that can automatically adjust and combine based on performance analysis, enabling compilers to explore large design spaces and produce optimized, low-noise quantum programs with minimal manual intervention. In parallel, this project also explores new approaches to analog quantum programming or quantum simulation, and has developed the programming language SimuQ which treats quantum Hamiltonian evolution as the central object.

97 MATHEMATICS AND COMPUTING↗

Generating nonlinear FM chirp radar signals by multiple integrations

A phase component of a nonlinear frequency modulated (NLFM) chirp radar pulse can be produced by performing digital integration operations over a time interval defined by the pulse width. Each digital integration operation includes applying to a respectively corresponding input parameter value a respectively corresponding number of instances of digital integration.

42 ENGINEERING↗

Material Characterization methods in InAs/InAsSb Type-II superlattices

This document presents a thesis proposal with three topics. It describes an in-depth comparison of lifetime measurement methods for material characterization of InAs/InAsSb type-II superlattices; develops a characterization method based on the 2nd harmonic of a modulated carrier density; and relates lifetime measurements to device performance.

36 MATERIALS SCIENCE↗

Nuclear Interdiction Through Relocatable Detectors

The NNSA Office of Nuclear Smuggling Detection and Deterrence (NSDD) has investigated a set of minimal-infrastructure radiation detection systems as alternatives to fixed Radiation Portal Monitors (RPMs) for nuclear interdiction applications. These versatile and relocatable systems can improve nuclear security in missions or locations that do not warrant or support a standard fixed radiation detection system. Over 2019, a variety of relocatable detectors were characterized at the Interdiction Technologies Integration Laboratory at Pacific Northwest National Laboratory (PNNL). Evaluated detectors were diverse in their size and capabilities, ranging from backpack-sized systems to lane-spanning cargo scanning portals. Both spectroscopic and non-spectroscopic pedestrian and vehicle detection systems were characterized against uranium and plutonium sources. Signatures from the sources were modulated by both shielding and distance to quantify the performance of the relocatable systems as signal strength was decreased. Findings showed that relocatable spectroscopic detectors with isotope identification capabilities could reduce nuisance alarm rates compared to conventional fixed installation, gross-counting, radiation portal monitors. In vehicle scanning applications, detection ability generally trended with detection volume, regardless of spectral capability. In pedestrian scanning applications, several smaller backpack-sized detector systems were found to be more sensitive to detecting material than pedestrian portal monitors. The results of this characterization effort have helped inform the deployment of versatile equipment to improve nuclear security missions.

relocatable detectors, Nuclear Security↗

Optical smoothing of laser imprinting in planar-target experiments on OMEGA EP using multi-FM 1-D smoothing by spectral dispersion

Direct-drive ignition on the National Ignition Facility (NIF) requires single-beam smoothing to minimize imprinting of laser nonuniformities that can negatively affect implosion performance. One-dimensional, multi-FM smoothing by spectral dispersion (SSD) has been proposed to provide the required smoothing [Marozas et al., Bull. Am. Phys. Soc. 55, 294 (2010)]. A prototype multi-FM SSD system has been integrated into the NIF-like beamline of the OMEGA EP Laser System. Experiments have been performed to verify the smoothing performance by measuring Rayleigh–Taylor growth rates in planar targets of laser-imprinted and preimposed surface modulations. Multi-FM 1-D SSD has been observed to reduce imprint levels by ∼50% compared to the nominal OMEGA EP SSD system. The experimental results are in agreement with 2-D DRACO simulations using realistic, time-dependent far-field spot-intensity calculations that emulate the effect of SSD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A patterned phase-changing vanadium dioxide film stacking with VO 2 nanoparticle matrix for high performance energy-efficient smart window applications

A vanadium dioxide (VO 2 ) based solid-to-solid phased changing material has been attracting great interest in smart window applications. However, achieving high solar modulation and high transparency simultaneously in visible light is the major challenge for the practical application of this smart material. To resolve this issue, in this paper, a smart film composed of a VO 2 nanoparticle matrix and a patterned VO 2 film is presented. Furthermore, numerical modeling and electromagnetic simulation are carried out to characterize the performance in terms of solar modulation and luminous transmittance, and a parametric study is carried out to optimize the proposed smart window film. Compared with the VO 2 nanoparticle matrix, the proposed structure can obtain 23% solar modulation and 57% luminous transmittance but with a much thinner thickness, which will significantly reduce the cost and fabrication complexity and extend the environment stability.

42 ENGINEERING↗

Fuel Performance Evaluation of THOR-C Experiments

The Temperature Heatsink Overpower Response Commissioning (THOR-C) and THOR-Metal (THOR-M) experiments will be performed as part of an ongoing project for testing sodium fast reactor fuels with the Japan Atomic Energy Agency (JAEA). The THOR-C experiments consist of fresh metallic fuel pins and have been analyzed using the ABAQUS, Ansys codes and the BISON fuel performance code. THOR-M-Loss of Flow-1 (THOR-M-LOF-1) is designed to test an EBR-II irradiated fuel pin under LOF conditions. Simulation of the THOR-MLOF-1 experiment required first simulating the base irradiation of the fuel pin in EBR-II. MFUEL module of SAS4A/SASSYS-1 [1] is a physics-based metallic fuel performance model applicable to the normal operation, transient scenarios and fuel failure modeling including scenarios with bulk fuel melting. The model has been validated using EBR-II normal operation, separate effect transient tests as well as TREAT M-Series transient tests [2]. In this study, MFUEL models has been utilized together with a new capsule heat transfer model developed in this project. The new heat transfer model was necessary due to (1) significant amount of heat losses that required 2D heat transfer, (2) the presence of a titanium heat sink, rejecting a significant amount of heat, and (3) stagnant coolant conditions, which are inconsistent with SAS4A/SASSYS-1 (SAS) heat transfer model. Updates to SAS4A/SASSYS-1 and MFUEL has been described below, followed by a preliminary validation effort using the results from THOR-C-2 fresh fuel capsule experiment. A previous study for THOR-C-2 analysis using BISON code is also utilized in this study to model this test [3]. [1] D. O’Grady, A. J. Brunett, L. Ibarra, A. Karahan, T. Kim, T. S. Sumner, R. Thomas, T. H. Fanning, “The SAS4A/SASSYS-2 Version 5.7 Safety Analysis Code System,” Argonne National Laboratory,ANL/NSE-SAS/5.7, (2023). [2] A. Karahan, T. Kim, T. Fanning, D. O’Grady, “Validation of MFUEL Metal Fuel Performance Models of SAS4A/SASSYS-1,” Argonne National Laboratory, ANL/NSE-23/11, (2023). [3] M. Mihelish, A. Zabriskie, K. Paaren, P. Medvedev, C. Jensen, “Fuel Performance Predictions for the TREAT THOR-C Experiments,” Idaho National Laboratory, INL/RPT-23-73397, Revision 0, (2023)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Real power regulation for the utility power grid via responsive loads

A system for dynamically managing an electrical power system that determines measures of performance and control criteria for the electric power system, collects at least one automatic generation control (AGC) input parameter to at least one AGC module and at least one automatic load control (ALC) input parameter to at least one ALC module, calculates AGC control signals and loads as resources (LAR) control signals in response to said measures of performance and control criteria, propagates AGC control signals to power generating units in response to control logic in AGC modules, and propagates LAR control signals to at least one LAR in response to control logic in ALC modules.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of space charge in the ICARUS T600 detector

The accumulation of positive ions, produced by ionizing particles crossing Liquid Argon Time Projection Chambers (LAr-TPCs), may generate distortions of the electric drift field affecting the track reconstruction of the ionizing events. These effects could become relevant for large LAr-TPCs operating at surface or at shallow depth, where the detectors are exposed to a copious flux of cosmic rays. We report a detailed study of such possible field distortions in the ICARUS T600 LAr-TPC has been performed analyzing a sample of cosmic muon tracks recorded with one T600 module operated at surface in 2001. The maximum track distortion turns out to be of few mm in good agreement with the prediction by a numerical calculation. As a cross-check, the same analysis has been performed on a cosmic muon sample recorded during the ICARUS T600 run at the LNGS underground laboratory, where the cosmic ray flux was suppressed by a factor $\sim 10^6$ by 3400 m water equivalent shielding. No appreciable distortion has been observed, confirming that the effects measured on surface are actually due to ion space charge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy

Purpose: The objective of this work is to present a new 2D plastic scintillation detectors array (2D-PSDA) designed for the dosimetry of megavoltage (MV) energy photon beams in radiation therapy and to characterize its basic performance. Methods: We developed a 2D detector array consisting of 781 plastic scintillation detectors (PSDs) inserted into a plane of a water-equivalent phantom. The PSDs were distributed on a 26 x 26 cm{sup 2} grid, with an interdetector spacing of 10 mm, except for two perpendicular lines centered on the detection plane, where the spacing was 5 mm. Each PSD was made of a 1 mm diameter by 3 mm long cylindrical polystyrene scintillating fiber coupled to a clear nonscintillating plastic optical fiber. All of the light signals emitted by the PSDs were read simultaneously with an optical system at a rate of one measurement per second. We characterized the performance of the optical system, the angular dependency of the device, and the perturbation of dose distributions caused by the hundreds of PSDs inserted into the phantom. We also evaluated the capacity of the system to monitor complex multileaf collimator (MLC) sequences such as those encountered in step-and-shoot intensity modulated radiation therapy (IMRT) plans. We compared our results with calculations performed by a treatment planning system and with measurements taken with a 2D ionization chamber array and with a radiochromic film. Results: The detector array that we developed allowed us to measure doses with an average precision of better than 1% for cumulated doses equal to or greater than 6.3 cGy. Our results showed that the dose distributions produced by the 6-MV photon beam are not perturbed (within {+-}1.1%) by the presence of the hundreds of PSDs located into the phantom. The results also showed that the variations in the beam incidences have little effect on the dose response of the device. For all incidences tested, the passing rates of the gamma tests between the 2D-PSDA and the treatment planning system were higher than 97.5% when the standard clinical tolerances of 3% or 3 mm were used. Excellent agreement was obtained between the doses measured and calculated when we used the 2D-PSDA for monitoring a MLC sequence from a step-and-shoot IMRT plan. Conclusions: We demonstrated the feasibility of using a large number of PSDs in a new 2D-PSDA for the dosimetry of MV energy photon beams in radiation therapy. The excellent precision, accuracy, and low angular dependence of the device indicate that such a prototype could potentially be used as a high-accuracy quality assurance tool for IMRT and arc therapy patient plan verification. The homogeneity and water-equivalence of the prototype we built suggest that this technology could be extended to multiple detection planes by arranging the fibers into more complex orientations, opening the possibility for 3D dosimetry with PSDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of structure and deformation behavior of AISI 316L tensile specimens from the second operational target module at the Spallation Neutron Source

In an earlier publication, tensile testing was performed on specimens removed from the first two operational targets of the Spallation Neutron Source (SNS). There were several anomalous features in the results. First, some specimens had very large elongations (up to 57%) while others had significantly smaller values. Second, there was a larger than the usual amount of data scatter in the elongation results. Third, the stress-strain diagrams of nominally similar specimens spanned a wide range of behavior ranging from expected irradiation-induced hardening to varying levels of force drop after yield point and indirect signs of "traveling deformation wave" behavior associated with strain-induced martensite formation. To investigate the cause(s) of such variable tensile behavior, several specimens from Target 2, spanning the range of observed tensile behavior, were chosen for detailed microstructural examination using electron backscattering analysis (EBSD). It was also shown that the steel employed in the construction of the target contained an unexpected bimodal grain size distribution, containing very large out-of-specification grains surrounded by necklaces of grains of within-specification sizes. The large grains were frequently comparable to the width of the gauge section of the tensile specimen. Moreover, the propensity to form martensite during deformation was shown to be accelerated by radiation but also to be very sensitive to the relative orientation of the grains with respect to the tensile axis. Specimens having large grains in the gauge that were most favorably oriented for production of martensite strongly exhibited the traveling deformation wave phenomenon, while those specimens with less favorably oriented grains had lesser or no degree of the wave effect, thereby accounting for the larger than expected data scatter.

316L↗

SU-E-T-483: Treatment Planning Study of Volumetric Modulated Arc Therapy for Left-Sided Breast and Chestwall Cancers

Purpose: To perform the comparison of dose distributions and dosevolume- histograms generated by VMAT and conventional field-in-field technique for left-sided breast and chestwall cancers; to determine whether VMAT offers more dosimetric benefits than does the field-in-field technique. Methods: All VMAT and field-in-filed plans were produced in Eclipse(version 10). Five plans were generated for left-sided breast and leftsided chestwall with supraclavicular nodes, respectively. A clockwise arc (CW) and a counter-clockwise arc (CCW) were used with start and stop angles being 310o±10o and 140o±10o. Collimator angles were 30o for CW and 330o for CCW. The conformity index (CI) is the ratio of V95% over PTV. The homogeneity index (HI) is the ratio of the difference between D2% and D98% over the prescribed dose. The V5, as an indicator of low dose bath to organs-at-risk, was used for ipsilateral lung, heart, contralateral lung, and contralateral breast. The V20, as an indicator of radiation pneumonitis, was used for ipsilateral lung. Results: Breast/chestwall VMAT delivers much higher low dose bath to ipsilateral lung, contralateral lung and contralateral breast/chestwall for both intact breast and chestwall with nodes. V5 for heart is increased in VMAT plans. V20 for ipsilateral lung is lower in VMAT plans. PTV coverage is similar for both techniques. For one particular chestwall patient with supraclavicular and internal mammary nodes, VMAT offers superior dose coverage of PTVs with slightly more low-dose-wash to heart, contralateral lung and contralateral breast. Conclusion: This study indicates that there is generally no benefit using VMAT for left-sided intact breast, due to large low-dose-bath (5Gy) to normal tissues with insignificant improvement in PTV coverage. Dosimetric benefits will be seen in VMAT plans for some chestwall patients with large size, and/or internal mammary nodes, etc. Whether a chestwall patient is treated with VMAT should be carefully analyzed on an individual basis.

60 APPLIED LIFE SCIENCES↗

Development of shashlik electromagnetic calorimeter prototype for SoLID

A shashlik electromagnetic calorimeter will be produced in Hall A of Jefferson Laboratory for Solenoidal large Intensity Device (SoLID) to measure the energy deposition of electrons and hadrons, and to provide particle identification after the energy of the accelerator was upgraded to 12 GeV. Tsinghua University is the member of Hall A collaboration in charge of development and production of the large shashlik electromagnetic calorimeter of SoLID. One module of that calorimeter is composed by 194 layers. Each layer consists of a 1.5 mm thick plastic scintillator put on top of a 0.5 mm thick lead plate. Scintillation light is read out by wave-length shifter fibers penetrating through the calorimeter modules longitudinally along the direction of flight of the impact particle. This paper describes the design and construction of that module, as well as a few optimization studies meant to improve its performance. A detailed Geant4 simulation also shows that an energy resolution of 5%/√ E (GeV) and a good containment for electromagnetic showers can be achieved, as well as some basic electron identification. In conclusion, a prototype of that module will be tested soon with an electron beam at JLab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Suppressing the enhancement of stimulated Raman scattering in inhomogeneous plasmas by tuning the modulation frequency of a broadband laser

The stimulated Raman scattering (SRS) instability can inhibit the performance of laser driven inertial confinement fusion (ICF) implosions by scattering light into unwanted directions or by generating hot electrons that preheat the target fuel. In principle, ICF target designs can avoid parameter regimes conducive to large, linear SRS gains. In practice, kinetic inflation—the nonlinear enhancement of SRS due to electron trapping in the excited plasma wave—makes this difficult. Here we show that laser bandwidth in the form of frequency modulation can either decrease or increase the inflationary SRS (iSRS) threshold in inhomogeneous plasmas depending on the maximum chirp of the laser pulse. The threshold, mapped out by a series of particle-in-cell simulations, exhibits a minimum when the frequency change within the pulse cancels the spatial detuning due to density inhomogeneities along the trajectory of the scattered light. In conclusion, by tuning the pump laser parameters away from this minimum, the iSRS threshold can be larger than at zero bandwidth, providing a path to mitigating kinetic inflation in ignition relevant plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗