Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Grain size determination in nano-scale polycrystalline aggregates by precession illumination-hollow cone dark field imaging in the transmission electron microscope

Precession illumination hollow cone dark field (PI-HCDF) transmission electron microscopy (TEM) provides high contrast multi-beam dark field images, which are suitable for effective and robust grain size measurements in nano-scale polycrystalline aggregates. Precession illumination with slightly converged electron beam probes and precession angles up to 3 Degree-Sign has been produced using a computer-controlled system using a JEOL JEM 2000FX TEM instrument. Theoretical and practical aspects of the experimental technique are discussed using example precession illumination hollow cone diffraction patterns from single crystalline NiAl and the importance of selecting the appropriate precession angle for PI-HCDF image formation and interpretation is described. Results obtained for precession illumination are compared with those of conventional parallel beam illumination experiments. Nanocrystalline Al has been used to evaluate the influence of the precession angle on PI-HCDF image contrast with a focus on grain size analysis. PI-HCDF imaging has been applied for grain size measurements in regions of a nanocrystalline Al thin film adjacent to the edge of a pulsed laser melted and rapidly solidified region and determined the dimensions of a heat-affected zone. - Highlights: Black-Right-Pointing-Pointer New TEM method for grain size measurements combines TEM resolution with obtainability of statistically significant data sets. Black-Right-Pointing-Pointer We use precession illumination to produce time precession illumination hollow cone diffraction patterns PI-HCDP. Black-Right-Pointing-Pointer Contrast in dark field images (PI-HCDF) formed from PI-HCDP is easy to interpret as dynamical effects are reduced. Black-Right-Pointing-Pointer PI-HCDFs use several time-averaged g-rings simultaneously and contain more information than conventional DF-images. Black-Right-Pointing-Pointer Easy contrast interpretation and less dark field images required, allows fast, robust and reliable grain size determination.

36 MATERIALS SCIENCE↗

Optical diabols in singular laser beams

Polarisation singularities and optical diabols in laser beams are studied experimentally by the developed method of digital Stokes-polarimetry. Three possible morphological forms of singularities with circular polarisation (C points) are found and their statistics in the speckle pattern of photoinduced scattering is determined. Singular fields with controllable parameters are realised and used for studying topological transformations, creation and annihilation of singularities and optical diabols. Both possible types of distributions of the major and minor semiaxes of polarisation ellipses in the beam cross section around C points (optical diabols) are measured. It is shown that, in accordance with the theory, the annihilation of pairs of elliptical diabols is preceded by their transformation to hyperbolic diabols. (laser beams)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Title Coherent X-ray Studies of Surface Growth and Patterning Processes

X-ray Photon Correlation Spectroscopy (XPCS) is being developed as a tool to study nanoscale dynamics of fluctuations during thin film growth and surface patterning. XPCS examines the evolution of the X-ray scattering speckle pattern in reciprocal space to reveal dynamics information not accessible through any other means. Unlike low-coherence conventional X-ray scattering, which incoherently averages over different regions of a sample, coherent X-ray scattering is sensitive to the detailed structure of a given sample at that moment in time. In thin film growth processes, heterodyning, which occurs due to coherent mixing of two scattered signals, can be used to investigate the relationship between surface growth velocity and defect propagation. And, for polycrystalline thin film growth, the spatial coherence of the X-ray beam can substitute for the missing spatial coherence of the growth process to track layered growth in detail, even in a growth regime in which there are no conventional growth oscillations of the X-ray intensity. This has opened the door for detailed dynamics studies of individual atomic layers during real-world growth and patterning, not just in perfect single-crystal growth cases, which greatly expands the applicability of in-situ X-ray scattering methods. Step-flow dynamics in mounded polycrystalline growth has been studied separately for two thin film organic semiconductors deposited by thermal deposition in a vacuum environment, C60 and diindenoperylene (DIP). Highly oriented polycrystalline thin films are readily obtained in both systems, where mounds are composed of crystalline monolayer-height steps and terraces in a so-called wedding cake morphology. The formation of mounds is understood to be due to significant Ehrlich-Schwoebel step edge barriers that inhibit molecules from hopping down from one layer to the one below. The mounds exhibit local step flow, which can be monitored using coherent X-ray scattering. This is made possible due to heterodyning between scattering from the average mounds and the moving steps, which becomes visible in XPCS analysis. The effect of desorption, i.e. re-evaporation of deposited molecules is found to be important for understanding these processes. The impact of this work is to enable testing of models of step dynamics, the shape of mounds, and merging of mounds to form continuous thin films. Highly ordered polycrystalline thin films deposited on inexpensive substrates have applications in thin film solar cells and other organic electronic devices. In a separate set of experiments, speckle analysis during self-organized ion beam nanopatterning reveals memory stretching back to the beginning of patterning in the early stages and enables measurement of the velocity of self-organized patterns across surfaces providing the possibility of stringent new tests of the theory of pattern formation and motion.

36 MATERIALS SCIENCE↗

Light by light diffraction in vacuum

We show that a laser beam can be diffracted by a more concentrated light pulse due to quantum vacuum effects. We compute analytically the intensity pattern in a realistic experimental configuration, and discuss how it can be used to measure the parameters describing photon-photon scattering in vacuum. In particular, we show that the quantum electrodynamics prediction can be detected in a single-shot experiment at future 100-PW lasers such as ELI or HIPER. On the other hand, if carried out at one of the present high-power facilities, such as OMEGA EP, this proposal can lead either to the discovery of nonstandard physics or to substantial improvement in the current limits by PVLAS collaboration on the photon-photon cross section at optical wavelengths. This example of manipulation of light by light is simpler to realize and more sensitive than existing, alternative proposals, and can also be used to test Born-Infeld theory or to search for axionlike or minicharged particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probe compensation in cylindrical near-field scanning: A novel simulation methodology

Probe pattern compensation is essential in near-field scanning geometry, where there is a great need to accurately know far-field patterns at wide angular range. This paper focuses on a novel formulation and computer simulation to determine the precise need for and effect of probe compensation in cylindrical near-field scanning. The methodology is applied to a linear test array antenna and the NASA scatterometer radar antenna. The formulation is based on representing the probe by its equivalent tangential magnetic currents. The interaction between the probe equivalent aperture currents and the test antenna fields is obtained with the application of a reciprocity theorem. This allows us to obtain the probe vector output pickup integral which is proportional to the amplitude and phase of the electric field induced in the probe aperture with respect to its position to the test antenna. The integral is evaluated for each probe position on the required sampling point on a cylindrical near-field surface enclosing the antenna. The use of a hypothetical circular-aperture probe with a different radius permits us to derive closed-form expressions for its far-field radiation patterns. These results, together with the probe vector output pickup, allow us to perform computer simulated synthetic measurements. The far-field patterns of the test antenna are formulated based on cylindrical wave expansions of both the probe and test antenna fields. In the limit as the probe radius becomes very small, the probe vector output is the direct response of the near-field at a point, and no probe compensation is needed. Useful results are generated to compare the far-field pattern of the test antenna constructed from the knowledge of the simulated near-field with and without probe pattern compensation and the exact results. These results are important since they clearly illustrate the angular range over which probe compensation is needed. It has been found that a probe with an aperture radius of 0.25(lambda), 0.5(lambda), and 1(lambda) needs a little probe compensation, if any, near the test antenna main beam. In addition, a probe with low directivity may provide a better signal-to-noise ratio than a highly directive one. This is evident in test antenna patterns without probe compensation at wide angles.

Hussein, Ziad A.↗

In-beam γ-ray spectroscopy of 68 Fe from charge exchange on 68 Co projectiles

Excited states in the neutron-rich nucleus 68 Fe were populated using a 9 Be( 68 Co, 68 Fe + γ)X charge-exchange reaction at 95 MeV/u. The new γ-ray transitions reported here for the first time complement data from β-decay studies and nucleon knockout reactions. In comparison to shell-model calculations with the LNPS effective interaction, two candidate states for the $6$$^{+}_{1}$ level emerge. Here, the distinct population pattern of excited states and the magnitude of the cross section, σ inc = 0.51(6) mb, make this reaction a promising one for future in-beam γ -ray spectroscopy. Reaction calculations with nuclear structure input from a new, locally optimized Hamiltonian, f7j4a, together with general considerations for heavy-ion-induced charge-exchange reactions appear consistent with most of the observations, although challenges remain.

59 ≤ A ≤ 89↗

Micro-fluidics and integrated optics glass sensor for in-line micro-probing of nuclear samples

We study the miniaturisation of Thermal Lens Spectrometry (TLS) towards Lab-on-chip integration in order to reduce the volume of fluid assays in nuclear process control. TLS is of great interest in this context since it combines the advantages of optical detection methods with an inherent suitability for small-scale samples. After validating the experimental principle in a classical thermal lens crossed-beam setup, we show the integration of a Young-interferometer with a microcapillary on a glass substrate, reducing the necessary sample size to 400 nl. The interferometer translates the photo-thermally induced refractive index change in the fluid to a phase shift of the fringe pattern, which can then be detected by a camera. Measurements of Co(II) in ethanol yield a detection limit of c = 5 x 10{sup -4} M for the crossed-beam setup and c = 6x10{sup -3} M for the integrated sensor. At an interaction length of 10 {mu}m, it detects a minimum absorbance of AU = 6 x 10{sup -5} in a probed volume of 10 pl. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micro-fluidics and integrated optics glass sensor for in-line micro-probing of nuclear samples

We study the miniaturization of Thermal Lens Spectrometry (TLS) towards Lab-on-chip integration in order to reduce the volume of fluid assays in nuclear process control. TLS is of great interest in this context since it combines the advantages of optical detection methods with an inherent suitability for small-scale samples. After validating the experimental principle in a classical thermal lens crossed-beam setup, we show the integration of a Young-interferometer with a microcapillary on a glass substrate, reducing the necessary sample size to 400 nl. The interferometer translates the photo-thermally induced refractive index change in the fluid to a phase shift of the fringe pattern, which can then be detected by a camera. Measurements of Co(II) in ethanol yield a detection limit of c = 5 x 10{sup -4} M for the crossed-beam setup and c = 6 x 10{sup -3} M for the integrated sensor. At an interaction length of 10 m, it detects a minimum absorbance of K = 1.2 x 10{sup -4} in a probed volume of 14 pl. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reducing Dose Uncertainty for Spot-Scanning Proton Beam Therapy of Moving Tumors by Optimizing the Spot Delivery Sequence

Purpose: To develop and validate a novel delivery strategy for reducing the respiratory motion–induced dose uncertainty of spot-scanning proton therapy. Methods and Materials: The spot delivery sequence was optimized to reduce dose uncertainty. The effectiveness of the delivery sequence optimization was evaluated using measurements and patient simulation. One hundred ninety-one 2-dimensional measurements using different delivery sequences of a single-layer uniform pattern were obtained with a detector array on a 1-dimensional moving platform. Intensity modulated proton therapy plans were generated for 10 lung cancer patients, and dose uncertainties for different delivery sequences were evaluated by simulation. Results: Without delivery sequence optimization, the maximum absolute dose error can be up to 97.2% in a single measurement, whereas the optimized delivery sequence results in a maximum absolute dose error of ≤11.8%. In patient simulation, the optimized delivery sequence reduces the mean of fractional maximum absolute dose error compared with the regular delivery sequence by 3.3% to 10.6% (32.5-68.0% relative reduction) for different patients. Conclusions: Optimizing the delivery sequence can reduce dose uncertainty due to respiratory motion in spot-scanning proton therapy, assuming the 4-dimensional CT is a true representation of the patients' breathing patterns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-210-03: Impact of Breathing Irregularities On Gated Treatments

Purpose: To evaluate the effect of breathing irregularities on target location in gated treatments using amplitude and phase gating. Methods: 111 breathing patterns acquired using RPM system were categorized based on period and amplitude STD as regular (STD period ≤ 0.5 s, STD amplitude ≤ 1.5 mm), medium (0.5 s < STD period ≤ 1 s, 1.5 mm < STD amplitude ≤ 3 mm) and irregular (STD period > 1 s, STD amplitude > 3 mm). One pattern representative of the average defined population was selected per category and corresponding target motion reproduced using Quasar Respiratory Motion Phantom. Phantom in motion underwent 4D-CT scan with phase reconstruction. Gated window was defined at end of exhale and DRRs reconstructed in treatment planning at 40% (beam on) and 60% phase (beam off). Target location uncertainty was assessed by comparing gated kV triggered images continuously acquired at beam on/off on a True Beam 2.0 with corresponding DRRs. Results: Average target uncertainty with amplitude gating was in [0.4 – 1.9] mm range for the different scenarios with maximum STD of 1.2 mm for the irregular pattern. Average target uncertainty with phase gating was [1.1 – 2.2] mm for regular and medium patterns, while it increased to [3.6 – 9.6] mm for the irregular pattern. Live gated motion was stable with amplitude gating, while increasing with phase gating for the irregular pattern. Treatment duration range was [68 – 160] s with amplitude and [70 – 74] s with phase gating. Conclusion: Breathing irregularities were found to affect gated treatments only when using phase gating. For regular and medium patterns no significant difference was found between the two gating strategies. Amplitude gating ensured stable gated motion within the different patterns, thus reducing intra-fraction target location variability for the irregular pattern and resulting in longer treatment duration.

60 APPLIED LIFE SCIENCES↗

Three-body decay of {sup 6}Be

Three-body correlations for the ground-state decay of the lightest two-proton emitter {sup 6}Be are studied both theoretically and experimentally. Theoretical studies are performed in a three-body hyperspherical-harmonics cluster model. In the experimental studies, the ground state of {sup 6}Be was formed following the {alpha} decay of a {sup 10}C beam inelastically excited through interactions with Be and C targets. Excellent agreement between theory and experiment is obtained demonstrating the existence of complicated correlation patterns that can elucidate the structure of {sup 6}Be and, possibly, of the A=6 isobars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Emission patterns of neutral pions in 40A MeV Ta+Au reactions

Differential cross sections of neutral pions emitted in {sup 181}Ta+{sup 197}Au collisions at a beam energy of 39.5A MeV have been measured with the two-arm photon spectrometer (TAPS). The kinetic energy and transverse momentum spectra of neutral pions cannot be properly described in the framework of the thermal model, nor when the reabsorption of pions is accounted for in a phenomenological model. However, high energy and high momentum tails of the pion spectra can be well fitted through thermal distributions with unexpectedly soft temperature parameters below 10 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coherent beam combining of pulsed fibre amplifiers with active phase control

Coherent beam combining of pulsed fibre lasers is a promising method for power scaling while simultaneously maintaining good beam quality. We propose and demonstrate a scalable architecture for coherent beam combining of all-fibre pulsed amplifiers with active phase control using the stochastic parallel gradient descent (SPGD) algorithm. A low-pass filter is introduced to eliminate the fluctuation of the metric function caused by pulsed lasers and to extract the exact phase noise signal. Active control is thereby based on the SPGD algorithm, resulting in stable coherent beam combining at the receiving plane even in a turbulent environment. Experimental results show that the fringe visibility of the long exposure pattern increases from 0 to 0.4, and the power encircled in the main-lobe increases by 1.6 times when the system evolves from the open-loop phase-locking scheme to the closed-loop scheme. This architecture can be easily scaled up to a higher power by increasing the number of amplifying channels and the power of a single amplifier.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-EF-207-09: Single-Scan Dual-Energy CT Using Primary Modulation

Purpose: Compared with conventional CT, dual energy CT (DECT) provides better material differentiation but requires projection data with two different effective x-ray spectra. Current DECT scanners use either a two-scan setting or costly imaging components, which are not feasible or available on open-gantry cone-beam CT systems. We propose a hardware-based method which utilizes primary modulation to enable single-scan DECT on a conventional CT scanner. The CT imaging geometry of primary modulation is identical to that used in our previous method for scatter removal, making it possible for future combination with effective scatter correction on the same CT scanner. Methods: We insert an attenuation sheet with a spatially-varying pattern - primary modulator-between the x-ray source and the imaged object. During the CT scan, the modulator selectively hardens the x-ray beam at specific detector locations. Thus, the proposed method simultaneously acquires high and low energy data. High and low energy CT images are then reconstructed from projections with missing data via an iterative CT reconstruction algorithm with gradient weighting. Proof-of-concept studies are performed using a copper modulator on a cone-beam CT system. Results: Our preliminary results on the Catphan(c) 600 phantom indicate that the proposed method for single-scan DECT is able to successfully generate high-quality high and low energy CT images and distinguish different materials through basis material decomposition. By applying correction algorithms and using all of the acquired projection data, we can reconstruct a single CT image of comparable image quality to conventional CT images, i.e., without primary modulation. Conclusion: This work shows great promise in using a primary modulator to perform high-quality single-scan DECT imaging. Future studies will test method performance on anthropomorphic phantoms and perform quantitative analyses on image qualities and DECT decomposition accuracy. We will use simulations to optimize the modulator material and geometry parameters.

60 APPLIED LIFE SCIENCES↗

Acoustic non-diffracting Airy beam

The acoustic non-diffracting Airy beam as its optical counterpart has unique features of self-bending and self-healing. The complexity of most current designs handicaps its applications. A simple design of an acoustic source capable of generating multi-frequency and broad-band acoustic Airy beam has been theoretically demonstrated by numerical simulations. In the design, a piston transducer is corrugated to induce spatial phase variation for transducing the Airy function. The piston's surface is grooved in a pattern that the width of each groove corresponds to the half wavelength of Airy function. The resulted frequency characteristics and its dependence on the size of the piston source are also discussed. This simple design may promote the wide applications of acoustic Airy beam particularly in the field of medical ultrasound.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of template variations on shape and arrangement of Si/Ge quantum dot arrays

Templated self-assembly allows the fabrication of quantum dot (QD) arrays for use in nanoelectronic devices. Here, we show the strong dependence of the shape and arrangement of QDs on the template structures. Arrays of etched pits are patterned on Si (100) substrates by extreme ultraviolet interference lithography on which Si/Ge layers are grown in a molecular beam epitaxy system. Single Ge dome clusters or quantum molecules consisting of four Ge hut clusters are obtained by a change of the pit diameter. Both arrays exhibit a narrow size distribution and exact alignment of the dots. In addition, multiple stacking of these arrays is demonstrated.

36 MATERIALS SCIENCE↗

Neutrino identification with scintillation light in MicroBooNE

MicroBooNE is a neutrino experiment which employs a liquid argon (LAr) time projection chamber (TPC) to record neutrino interactions from Fermilab's neutrino beamlines. The experiment's primary objective is to study low-energy νe interactions from the Booster Neutrino Beamline (BNB). Located on the surface, the detector is affected by a continuous rate of cosmic-rays. This leads to one neutrino interaction for every 104 cosmic rays observed in the TPC, making it difficult to isolate neutrino interactions in the detector using charge alone. MicroBooNE's trigger makes use of prompt scintillation light and plays an essential role in both performing strong background rejection and significantly reducing data-rates. Furthermore, a series of novel techniques relying on scintillation light are used to isolate beam-induced activity. This document briefly presents MicroBooNE's scintillation-light based trigger and novel Flash-Matching pattern recognition techniques for cosmic-rejection. This work serves as the foundation of neutrino analyses in LArTPC detectors and is therefore of interest to the broader short- and long-baseline neutrino programs being launched at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-BRA-11: Tumor Tracking in An Iterative Volume of Interest Based 4D CBCT Reconstruction

Purpose: 4D CBCT can allow evaluation of tumor motion immediately prior to radiation therapy, but suffers from heavy artifacts that limit its ability to track tumors. Various iterative and compressed sensing reconstructions have been proposed to reduce these artifacts, but are costly time-wise and can degrade the image quality of bony anatomy for alignment with regularization. We have previously proposed an iterative volume of interest (I4D VOI) method which minimizes reconstruction time and maintains image quality of bony anatomy by focusing a 4D reconstruction within a VOI. The purpose of this study is to test the tumor tracking accuracy of this method compared to existing methods. Methods: Long scan (8–10 mins) CBCT data with corresponding RPM data was collected for 12 lung cancer patients. The full data set was sorted into 8 phases and reconstructed using FDK cone beam reconstruction to serve as a gold standard. The data was reduced in way that maintains a normal breathing pattern and used to reconstruct 4D images using FDK, low and high regularization TV minimization (λ=2,10), and the proposed I4D VOI method with PTVs used for the VOI. Tumor trajectories were found using rigid registration within the VOI for each reconstruction and compared to the gold standard. Results: The root mean square error (RMSE) values were 2.70mm for FDK, 2.50mm for low regularization TV, 1.48mm for high regularization TV, and 2.34mm for I4D VOI. Streak artifacts in I4D VOI were reduced compared to FDK and images were less blurred than TV reconstructed images. Conclusion: I4D VOI performed at least as well as existing methods in tumor tracking, with the exception of high regularization TV minimization. These results along with the reconstruction time and outside VOI image quality advantages suggest I4D VOI to be an improvement over existing methods. Funding support provided by CPRIT grant RP110562-P2-01.

60 APPLIED LIFE SCIENCES↗