Search NASA⌕ Search

SEARCH · Search NASA

Results for “replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Pozzolanic reactivity of natural pozzolans, ground glasses and coal bottom ashes and implication of their incorporation on the chloride permeability of concrete

It is well understood that the partial replacement of portland cement with pozzolans in sufficient proportions results in improved long-term performance of concrete. However, dwindling availability of the most widely used pozzolan in the construction industry, fly ash, is forecast due to the termination of coal-fired electricity power stations around the world, necessitating the exploration of alternative pozzolans. Experimental investigations are conducted to study the performance of traditional pozzolans such as fly ash, silica fume and natural pozzolans (metakaolin, pumice, perlite and lassenite) together with novel pozzolans, including ground glasses (high-alkali and low-alkali), and ground bottom ash. Twenty-one concrete mixtures are examined for compressive strength, electrical conductivity, electrical resistivity, chloride permeability, and chloride migration coefficient. The reactivity of pozzolans studied is also determined in terms of compressive strength in lime-pozzolan mortar using a modified lime-reactivity test method. Many of the materials tested demonstrate the potential to be used in place of fly ash. However, a wide variation in the performance of these materials is evident which highlights the need for a reliable test to determine the level of reactivity of a pozzolan. The results indicate that the 7-day strength in the modified lime-reactivity test provides a good indication of the pozzolanic reactivity of the material and of how the material can be expected to contribute to the strength and permeability of concrete. The use of electrical resistivity as an indicator of the performance of pozzolans in terms of strength development and chloride penetration resistance when used to partially replace portland cement in concrete is also discussed.

36 MATERIALS SCIENCE↗

Performance of fly ash concrete with ferronickel slag fine aggregate against alkali-silica reaction and chloride diffusion

Ferronickel slag (FNS) is an industrial by-product of ferronickel alloy production at a high temperature which can be a promising potential to be used as fine aggregate to produce more sustainable concrete. In this study, the performance of concrete containing ferronickel slag sand and fly ash relating to alkali-silica reaction (ASR) and chloride contamination was investigated. ASR-induced expansion, chloride diffusion resistance, and chloride binding capacity of FNS concrete were determined through concrete prism tests (CPT), accelerated diffusion test, and bulk diffusion test. Thermogravimetric analysis (TGA) was conducted to measure the amount of Portlandite and Friedel's salt in concrete. Concrete with 50 wt% FNS sand as fine natural aggregate replacement and 25 wt% of cement replacement by fly ash showed a remarkable potential to be used not only as a low-carbon concrete with comparable mechanical properties to conventional concrete but also with a better performance against ASR and chloride contamination.

36 MATERIALS SCIENCE↗

Efficiency of natural pozzolans, ground glasses and coal bottom ashes in mitigating sulfate attack and alkali-silica reaction

The use of pozzolans to partially replace Portland cement in concrete has generally demonstrated beneficial impacts on the durability characteristics of concrete for decades. In this paper a diverse range of pozzolans including natural pozzolans, ground glasses and industrial by-products such as coal ash (fly ash and bottom ash) and silica fume were investigated for their synergistic potential in binary or ternary blends with Portland cement in improving resistance to chemical sulfate attack and alkali-silica reaction (ASR). It is generally considered that pozzolans improve most of the durability issues encountered in concrete, including reducing the risk of sulfate attack or ASR. But this is not always the case. For example, it was found that ground glasses were very efficient in improving sulfate resistance, but their ability to mitigate expansion due to ASR was dictated by the equivalent alkalis content (Na{sub 2}O{sub e}) of the glass and high-alkali soda glass was generally not effective in this role. On the other hand, metakaolin, a highly reactive pozzolan, was highly effective in reducing ASR expansion, but may actually increase the damage due to sulfate attack when used at moderate replacement levels. Most pozzolans, such as low-CaO coal fly ash and ground coal bottom ash, silica fume, and pumice, were effective in controlling expansion due to both ASR and sulfate attack. The results demonstrated that the extent of the positive impact of using natural pozzolans on both properties was variable. The pozzolanic reactivity of materials alone was an unreliable indicator to assess the ability of the pozzolan to suppress expansion due to sulfate attack or ASR.

36 MATERIALS SCIENCE↗

Prompt-NO formation in methane/oxygen/nitrogen flames seeded with oxygenated volatile organic compounds: Methyl ethyl ketone or ethyl acetate

In the present work, CH and NO profiles are determined using laser-induced fluorescence (LIF) measurements in eight low-pressure laminar flames of CH{sub 4}/O{sub 2}/N{sub 2} containing various amounts of methyl ethyl ketone or ethyl acetate with respect to the equivalence ratio. Relative CH LIF signals are calibrated using cavity ring-down spectroscopy (CRDS), while NO LIF calibration is performed in the burned gases of NO seeded flames. Temperature measurements are obtained using a coated Pt/Rh thermocouple and serve as temperature profiles input for Chemkin modeling. Volatile organic compound (VOC) submechanisms, previously validated upon major and intermediate species profiles measured using sampling techniques, are incorporated into the GDF-Kin 3.0{sub N}CN for the CH{sub 4} oxidation. This mechanism is adjusted and validated to predict the effect of VOCs seeding on CH and NO formation. It takes into account not only the CH and NO profiles but those previously measured. When methane is replaced by either MEK or EA, the NO mole fraction in the burned gases and the CH peak value are found to jointly decrease, indicating that NO is mainly formed according to the prompt-NO mechanism. According to the kinetic analysis, the VOC impact on NO formation is demonstrated. It is shown that CH radical formation, through the C1 sequence, mainly involves the CH{sub 3} radical, which is formed with the same propensity by one molecule of methane, MEK, or EA. Due to the methane replacement by VOC while the equivalence ratio is maintained constant, we found that the CH peak value decrease follows the total fuel volumetric flow rate decrease, yielding, an NO decrease in the burned gases. (author)

2-3-PENTANEDIONE↗

Large eddy simulation of extinction and reignition with artificial neural networks based chemical kinetics

Large eddy simulation (LES) of a non-premixed, temporally evolving, syngas/air flame is performed with special emphasis on speeding-up the sub-grid chemistry computations using an artificial neural networks (ANN) approach. The numerical setup for the LES is identical to a previous direct numerical simulation (DNS) study, which reported considerable local extinction and reignition physics, and hence, offers a challenging test case. The chemical kinetics modeling with ANN is based on a recent approach, and replaces the stiff ODE solver (DI) to predict the species reaction rates in the subgrid linear eddy mixing (LEM) model based LES (LEMLES). In order to provide a comprehensive evaluation of the current approach, additional information on conditional statistics of some of the key species and temperature are extracted from the previous DNS study and are compared with the LEMLES using ANN (ANN-LEMLES, hereafter). The results show that the current approach can detect the correct extinction and reignition physics with reasonable accuracy compared to the DNS. The syngas flame structure and the scalar dissipation rate statistics obtained by the current ANN-LEMLES are provided to further probe the flame physics. It is observed that, in contrast to H{sub 2}, CO exhibits a smooth variation within the region enclosed by the stoichiometric mixture fraction. The probability density functions (PDFs) of the scalar dissipation rates calculated based on the mixture fraction and CO demonstrate that the mean value of the PDF is insensitive to extinction and reignition. However, this is not the case for the scalar dissipation rate calculated by the OH mass fraction. Overall, ANN provides considerable computational speed-up and memory saving compared to DI, and can be used to investigate turbulent flames in a computationally affordable manner. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct in-situ observation of early age void evolution in sustainable cement paste containing fly ash or limestone

This paper uses fast X-ray Computed Tomography (fCT) to study the change in air-filled voids during hydration of portland cement pastes of different water to cement ratios and with fly ash and limestone additives between 30 min and 12 h of hydration with deionized and de-aired water. For the deionized samples, the total volume of the air-filled voids increased during the induction period and decreased as the acceleration period began and finally stayed constant. The samples with 20% replacement of fly ash and 20% replacement of limestone showed the same trends as the OPC samples but with a reduction in the observed air-filled void formation. The air-filled void distribution in these samples changed from a limited number of large voids at the beginning of the measurements to a system with a significantly greater number of uniformly distributed smaller voids. The changes in the air-filled voids were not significant in pastes made with 50% fly ash or with de-aired water in the same testing condition. This might be explained by differences in pore solution chemistry and a reduced amount of dissolved air in the mixing water. A mechanism is proposed for a change in ionic concentration in solution to cause release of the dissolved air within the mixing water.

Cement hydration↗

Assessing the hygrothermal performance of bio-based materials in building wall systems

Building envelope systems are crucial in regulating thermal and moisture exchange between interior and exterior environments, accounting for approximately 28 % of building energy consumption in the United States with walls being the primary contributors. Improper selection of building envelope materials can lead to moisture-related issues, reduced resilience, and compromised durability. Hygrothermal performance assessment is a key factor in efficient building design. As such, improving the energy and hygrothermal performance of opaque wall materials, through careful assessment of material choices, is essential to enhancing building resilience, lowering energy costs, and improving occupant comfort. As the building industry seeks new strategies to reduce material energy intensity, bio-based materials emerge as a promising solution. However, their long-term hygrothermal performance in building envelope systems remains underexplored. To fill this gap, this study evaluates the hygrothermal behavior of 13 bio-based materials in residential wall systems across three U.S. climate zones. Laboratory experiments were performed to measure material properties such as density, thermal conductivity, moisture transmission, and sorption isotherms. These data were integrated into the WUFI® simulation tool to assess wall hygrothermal performance in Houston, Baltimore, and Chicago. A three-phase modeling approach was used: (1) baseline residential walls with oriented strand board (OSB) and gypsum board; (2) replacing OSB with bio-based materials; and (3) replacing drywall with bio-based materials. Results showed that the evaluated bio-based materials maintained acceptable moisture thresholds of ≤ 16 % across all climates, confirming their viability as an alternative for current sheathing materials. Furthermore, this study provides a foundation for future research and innovation in material science on the use of certain bio-based materials in high-performance, low energy use residential construction. Ultimately, providing critical data, offering a database of bio-based material properties, and supplying a simulation-based approach will help designers make informed decisions for future efficient building practices.

Bio-based materials↗

Atomic-level heterogeneity and defect dynamics in concentrated solid-solution alloys

Performance enhancement of structural materials in extreme radiation environments has been activelyinvestigated for many decades. Traditional alloys, such as steel, brass and aluminum alloys, normallycontain one or two principal element(s) with a low concentration of other elements. While these existin either a mixture of metallic phases (multiple phases) or in a solid solution (single phase), limited orlocalized chemical disorder is a common characteristic of the main matrix. Fundamentally different fromtraditional alloys, recently developed single-phase concentrated solid-solutio n alloys (CSAs) contain mul-tiple elemental species in equiatomic or high concentrations with different elements randomly arrangedon a crystalline lattice. Due to the lack of ordered elemental arrangement in these CSAs, they exhibit sig-nificant chemical disorder and unique site-to-site lattice distortion. While it is well recognized intraditional alloys that minor additions lead to enhanced radiation resistance, it remains unclear inCSAs how atomic-level heterogeneity affects defect formation, damage accumulation, and microstruc-tural evolution. These knowledge gaps have acted as roadblocks to the development of future-generation energy technology. CSAs with a simple crystal structure, but complex chemical disorder,are unique systems that allow us, through replacing principal alloying elements and modifying concen-trations, to study how compositional complexity influences defect dynamics, and to bridge the knowl-edge gaps through understanding intricate electronic- and atomic-level interactions, mass and energytransfer processes, and radiation resistance performance. Recent advances in defect dynamics and irradi-ation performance of CSAs are reviewed, intrinsic chemical effects on radiation performance arediscussed, and direction for future studies is suggested.

Zhang, Yanwen↗

Accelerating nuclear configuration interaction calculations through a preconditioned block iterative eigensolver

We describe a number of recently developed techniques for improving the performance of large-scalenuclear configuration interaction calculations on high performance parallel computers. We show thebenefit of using a preconditioned block iterative method to replace the Lanczos algorithm that hastraditionally been used to perform this type of computation. The rapid convergence of the block iterativemethod is achieved by a proper choice of starting guesses of the eigenvectors and the construction of aneffective preconditioner. These acceleration techniques take advantage of special structure of the nuclearconfiguration interaction problem which we discuss in detail. The use of a block method also allows usto improve the concurrency of the computation, and take advantage of the memory hierarchy of modernmicroprocessors to increase the arithmetic intensity of the computation relative to data movement. Wealso discuss the implementation details that are critical to achieving high performance on massivelyparallel multi-core supercomputers, and demonstrate that the new block iterative solver is two to threetimes faster than the Lanczos based algorithm for problems of moderate sizes on a Cray XC30 system.

Shao, Meiyue↗

A protocol for lifetime energy and environmental impact assessment of building insulation materials

This article describes a proposed protocol that is intended to provide a comprehensive list of factors to be considered in evaluating the direct and indirect environmental impacts of building insulation materials, as well as detailed descriptions of standardized calculation methodologies to determine those impacts. The energy and environmental impacts of insulation materials can generally be divided into two categories: (1) direct impact due to the embodied energy of the insulation materials and other factors and (2) indirect or environmental impacts avoided as a result of reduced building energy use due to addition of insulation. Standards and product category rules exist, which provide guidelines about the life cycle assessment (LCA) of materials, including building insulation products. However, critical reviews have suggested that these standards fail to provide complete guidance to LCA studies and suffer from ambiguities regarding the determination of the environmental impacts of building insulation and other products. The focus of the assessment protocol described here is to identify all factors that contribute to the total energy and environmental impacts of different building insulation products and, more importantly, provide standardized determination methods that will allow comparison of different insulation material types. Further, the intent is not to replace current LCA standards but to provide a well-defined, easy-to-use comparison method for insulation materials using existing LCA guidelines. - Highlights: • We proposed a protocol to evaluate the environmental impacts of insulation materials. • The protocol considers all life cycle stages of an insulation material. • Both the direct environmental impacts and the indirect impacts are defined. • Standardized calculation methods for the ‘avoided operational energy’ is defined. • Standardized calculation methods for the ‘avoided environmental impact’ is defined.

54 ENVIRONMENTAL SCIENCES↗

Digital archives, big data and image-based culturomics for social impact assessment: Opportunities and challenges

Social impact assessment (SIA) is well-established but uses conventional approaches that have become less effective in recent decades, particularly in relation to declining survey response rates and a lack of youth engagement. Images from digital archives and social media sources are poised to advance the research and practice of SIA by transcending text-based methods with insights into changing landscapes, and human engagement with them. This viewpoint describes progress, challenges and cautions toward the development of such tools (defined as culturomics), using hydroelectricity cases to illustrate potential approaches. These tools build on foundational work in a range of disciplines, including the humanities and computer science. We describe necessary advances in machine learning, image digitization, and data aggregation and visualization techniques, as well as ways to ensure that such tools are carefully tested, applied and interpreted. Challenges include the automation, acquisition and management of datasets, and using these tools appropriately and equitably. Critically, culturomics of any kind must not be used as a replacement for engagement with people, but as complementary to inclusive stakeholder engagement. - Highlights: •Image-based digital archives and social media present opportunities for new SIA tools. •Application-ready big data approaches are emerging across many fields. •SIA scholars, practitioners and stakeholders should engage with culturomics. •Challenges include automation, digitization, interpretation and justice. •Culturomics of any kind must not replace engagement with people.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

How Do Electricity Pricing Programs Impact the Selection of Energy Efficiency Measures? - A Case Study with U.S. Medium Office Buildings

Building owners usually select energy efficiency measures (EEMs) by referring to return on investment (ROI). Current studies tend to apply static energy price to estimate ROI. However, more and more buildings are adopting dynamic electricity pricing programs. To understand how electricity pricing programs impact the selection of EEMs, this paper presents an analysis of the ROIs of EEMs under different pricing programs using U.S. medium office buildings as an example. Eight EEMs in four typical cities are selected as case studies. Considering five electricity pricing programs scenarios (one static program and four dynamic programs), EEMs are selected based on their ROIs. The main findings are: (1) The ROIs of EEMs change under different pricing programs. (2) In Honolulu, Buffalo, and Denver, replacing interior fixtures with higher-efficiency fixtures has a significantly higher ROI than the rest EEMs under all five pricing programs. However, the ROI of this EEM in Honolulu ranges from 28% to 47% for different pricing programs. (3) Similarly, in Fairbanks, replace heating coil with higher-efficiency coil produce higher ROI than the rest under all five pricing programs. (4) For other EEMs, their ROI rankings vary according to electricity pricing programs.

demand response↗

Miscellaneous Electric Loads: Characterization and Energy Savings Potential

Over time, miscellaneous electric loads (MELs) are expected to increase both in magnitude and share of residential and commercial building energy consumption. This trend is most apparent in North America, but it is also occurring in Japan and Europe. However, the contribution of MELs to building energy use is not currently well understood, both because the products in this category are transforming rapidly and the definition and classification of MELs is ambiguous. This study estimated the national energy consumption of 36 MELs using best-available data and found them to comprise 12% of delivered electricity to the U.S. residential and commercial building sectors. If 26 of these MELs were replaced with the most energy-efficient product models available on the market, their energy consumption could be halved to 6% of delivered electricity. National energy models will better account for building energy consumption by incorporating the MELs data collected and analyzed for this study, leading to improved policy decisions.

Miscellaneous electric loads, Plug loads, Taxonomy↗

Carbon and energy cost impacts of electrification of space heating with heat pumps in the US

In order to meet climate goals, it will be necessary to significantly reduce the greenhouse gases emitted by homes. A key factor in the US is to reduce the on-site combustion of fossil fuels for heating end-uses and to replace this with use of electric heat pump technologies connected to a low-carbon grid. The replacement of natural gas furnaces with electric heat pumps is a key home decarbonization strategy. However, the potential for space heating electrification to reduce greenhouse gas emissions depends on the carbon dioxide equivalent (CO 2 e) content of the electricity used by the heat pump. This varies considerably depending on the source of electricity, with large state to state variability. Furthermore, household energy costs are likely to be impacted by the electrification of space heating, because retail energy prices for both natural gas and electricity in each state vary by factors of seven and four, respectively. Contractors, energy programs, government and building code officials, as well as consumers need clear indications of the likely CO 2 e and energy cost impacts of proposed electrification projects, because these will affect decarbonization choices and rationales around scaled heating electrification. Government and utility programs also need to be aware of the likely outcomes of any supported/incentivized measures. Here, in this paper, we investigate these effects by looking at new metrics to analyze the change in CO 2 e emitted and the cost to meet home heating loads when switching from a natural gas furnace to a heat pump for the contiguous 48 states of the mainland US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and field demonstration of residential air source integrated heat pump using a three-stage compressor

To promote decarbonization and all electrification at residential sectors, it is necessary to use air source heat pumps (ASHPs) to replace natural gas for space heating and water heating. ASHPs are widely utilized for residential space cooling, heating, and water heating due to their simplicity and cost-effectiveness. However, their performance can be compromised in cold climates, where they may experience reduced heating capacity. A multi-functional heat pump, using a single compressor, to meet all home space conditioning and water heating demands, is an emerging technology. To address this limitation, we have developed and demonstrated an air source integrated heat pump to fulfill comprehensive home comfort requirements. This system employs a three-stage compressor and a single set of heat exchangers and valves, optimizing functionality while minimizing costs. The performance of the developed system was rigorously evaluated in both laboratory and field settings. In laboratory conditions, the system achieved a Seasonal Energy Efficiency Ratio of 17.0 (average COP of 4.98) and a Heating Seasonal Performance Factor of 11.0 (3.22). Additionally, in its most efficient operational mode—combining space cooling and water heating—the unit attained a total energy efficiency exceeding 7.0 seasonal COP in the field and could heat a 189-liter tank of water in just 25 min. The field study corroborated the laboratory findings, validating the system’s performance in real-world conditions. Here, this integrated heat pump represents an ideal solution for decarbonizing homes in northern climates by providing efficient space heating and water heating, thereby replacing the need for natural gas.

Integrated heat pump↗

Time-Dependent Electric Bus and Charging Station Deployment Problem

Battery electric buses (BEBs) have gained popularity due to their emission-free and energy-efficient features. Many transit authorities worldwide have set goals to gradually replace their bus fleets with BEBs. Considering the potential decline in BEB battery and charger prices, this study proposes a time-dependent bus fleet transition model to determine the optimal bus fleet transition plan, which includes selecting the bus lines to be electrified, determining the timing and type of BEBs to be purchased, and deploying on-route fast chargers and depot chargers. The model is a bi-objective integer linear program that considers the trade-off between electrified transit mileages and bus electrification costs. A normalized normal constraint method is applied to solve the bi-objective optimization model. The effectiveness of the proposed model is tested using a real-world bus network. Additionally, sensitivity analyses are conducted to better understand the impact of different parameter values on the optimal solutions. Our proposed model can provide transit authorities with a powerful tool to make informed decisions about their BEB fleet replacement plans.

ADVANCED PROPULSION SYSTEMS↗

Early nuclear retirements in deregulated U.S. markets: Causes, implications and policy options

Here, electricity prices have fallen significantly since 2008, putting commercial nuclear reactors in the United States under substantial financial pressure. In this market environment driven by persistently low natural gas prices and stagnant electricity demand, we estimate that about two thirds of the 100 GW nuclear capacity are uncompetitive over the next few years under the current trajectory. Among those, 18 GW are retiring or are merchant plants at high risk of retiring prematurely. The potential consequences of the hypothetical withdrawal of 20 GW of nuclear capacity include: 1) a ~3.2% increase in carbon emissions if replaced by gas-fired units or 2) a significant increase in cost if replaced by renewables. Without a carbon price, out-of-the-market payments would be needed to effectively maintain merchant nuclear capacity. Filling the revenue gap would come at a fleet-average cost of 3.5-5.5/ MWh for these plants, which is much lower than the cost of subsidizing wind power. The policy support could take the form of direct zero-emission credits, renewable portfolio standard expansion, or clean capacity market mechanisms. As a last resort, the exercise of a new mothballing status could prevent the irreversible retirement of nuclear power assets.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance of low-cost monitors to assess household air pollution

Highlights: • We assessed PM{sub 2.5} and CO low-cost monitors in semi-controlled and field studies. • Devices experienced high failure rate and susceptibility to environmental changes. • Low-cost monitors tested may not be ready to replace more established methods. Exposure to household air pollution is a leading cause of morbidity and mortality globally. However, due to the lack of validated low-cost monitors with long-lasting batteries in indoor environments, most epidemiologic studies use self-reported data or short-term household air pollution assessments as proxies of long-term exposure. We evaluated the performance of three low-cost monitors measuring fine particulate matter (PM{sub 2.5}) and carbon monoxide (CO) in a wood-combustion experiment conducted in one household of Spain for 5 days (including the co-location of 2 units of HAPEX and 3 units of TZOA-R for PM{sub 2.5} and 3 units of EL-USB-CO for CO; a total of 40 unit-days). We used Spearman correlation (ρ) and Concordance Correlation Coefficient (CCC) to assess accuracy of low-cost monitors versus equivalent research-grade devices. We also conducted a field study in India for 1 week (including HAPEX in 3 households and EL-USB-CO in 4 households; a total of 49 unit-days). Correlation and agreement at 5-min were moderate-high for one unit of HAPEX (ρ = 0.73 / CCC = 0.59), for one unit of TZOA-R (ρ = 0.89 / CCC = 0.62) and for three units of EL-USB-CO (ρ = 0.82–0.89 / CCC = 0.66–0.91) in Spain, although the failure or malfunction rate among low-cost units was high in both settings (60% of unit-days in Spain and 43% in India). Low-cost monitors tested here are not yet ready to replace more established exposure assessment methods in long-term household air pollution epidemiologic studies. More field validation is needed to assess evolving sensors and monitors with application to health studies.

54 ENVIRONMENTAL SCIENCES↗