Search NASA⌕ Search

SEARCH · Search NASA

Results for “scan pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

A novel technique for investigation of complete and partial anisotropic wetting on structured surface by X-ray microtomography

An experimental study about the anisotropic wetting behavior of a surface patterned with parallel grooves is presented as an application example of a novel technique for investigation of complete and partial anisotropic wetting on structured surface by X-ray microtomography. Shape of glycerin droplets on such surface is investigated by X-ray micro computed tomography (microCT) acting as a non-intrusive, full volume 3D microscope with micrometric spatial resolution. The reconstructed drop volumes enable to estimate the exact volumes of the drops, their base contours, and 3D static contact angles, based on true cross-sections of the drop-surface couple. Droplet base contours are compared to approximate geometrical contour shapes proposed in the literature. Contact angles along slices parallel and perpendicular to the grooves direction are compared with each other. The effect of the sessile drop volume on the wetting behavior is discussed. The proposed technique, which is applicable for any structured surface, enables the direct measure of Wenzel ratio based on the microCT scan in the wetted region usually inapproachable by any others. Comparisons with simplified models are presented and congruence of results with respect to the minimum resolution needed is evaluated and commented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin dynamics in permalloy nano-ellipses for honeycomb and square lattices

We report experimental and theoretical studies of spin dynamics in lattice structures of permalloy (Ni 80 Fe 20 ) nano-ellipses, with four different types of networks including honeycomb and square lattices. The lattices are patterned at the center line of the co-planar wave guide and consist of non-contacting or contacting ellipses. Micromagnetic simulations show excellent agreement with the broadband ferromagnetic resonance (FMR) experimental results. We find the existence of a spin-wave mode localized in the vertex region of the contacting nano-ellipse network. Our finding has important implications when designing an artificial spin ice (ASI) network for functional magnonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature-dependent quantitative 3{omega} scanning thermal microscopy: Local thermal conductivity changes in NiTi microstructures induced by martensite-austenite phase transition

We develop the theoretical description of 3{omega} signals from the resistive Wollaston thermal probe (ThP) of a scanning thermal microscope (SThM) in terms of an equivalent low-pass filter. The normalized amplitude and phase frequency spectra are completely characterized by a single parameter, the crossover frequency f{sub c}(k) depending on the sample thermal conductivity k. The application concerns polycrystalline NiTi shape memory alloy microstructured by focused Ga ion beam milling and implantation. The calibration of the ThP combined with a novel two-step normalization procedure allowed quantitative exploitation of 3{omega} signal variations as small as -1.75% in amplitude and 0.60 deg. in phase upon heating the sample from room temperature to 100 deg. C. This corresponds to k increase of 23.9% that is consistent with the expected thermal conductivity variation due to martensite-austenite structural phase transition. To our knowledge this is for the first time that SThM 3{omega} phase information is used quantitatively as well. The static, calibrated 3{omega} measurements are complementary to 3{omega} SThM images of the patterned sample surface. The local SThM measurement of temperature-dependent thermal conductivity opens the possibility to imaging structural phase transitions at submicron scale.

36 MATERIALS SCIENCE↗

Quartz conditioning crystal for X-ray rocking curve topography

A large α-quartz crystal designed to condition the monochromatic beam at beamline 1-BM of the Advanced Photon Source is presented. The purpose of this crystal was to provide a precise match to the Bragg angle of quartz crystals that are commonly used to make analyzers for plasma diagnostics. In order to characterize these analyzers, area detectors need to be positioned at distances from the analyzer at upwards of 1000 mm. As a result of this precise matching, a Bragg-reflected beam from such an analyzer is precisely parallel to the beam incident on the conditioning crystal. This situation alleviates the need to adjust the position of the area detector as the distance between the analyzer and the area detector is varied. That is, there is no need to account for vertical displacement of the diffracted-beam image as a function of this distance. Additionally, verification that the analyzer is set to the correct Bragg reflection is obtained by scanning this distance, because only for a spurious reflection will there be a vertical displacement. This is a very useful check. To commission the conditioning crystal, diffraction from a high-quality flat quartz crystal was mapped using a CCD. Bragg diffraction from the 40$\bar{40}$ reflection at 8.5 keV was studied over an area of 23 × 31 mm. The theoretical Darwin width of the flat sample in this case was 4.7 µrad. An FWHM value near 6 µrad was measured over almost the entire mapped area. These data demonstrate that the resolution function for this four-crystal arrangement is ~4 µrad. Data are also presented for a 0.1 mm-thick α-quartz wafer pressed into a concave form, having a nominal radius of 500 mm and intended for use as an analyzer. Because analyzers are bent crystals, diffraction occurs in narrow bands. When a multiple exposure is made as a function of rocking angle a striped pattern is obtained, which is commonly referred to as a zebra-stripe pattern. A series of zebra stripes from the 30$\bar{33}$ Bragg reflection of the bent wafer over its 25 mm-diameter area were recorded on a CCD. The zebra-stripe pattern was analyzed to show a uniform bending to a radius of 497.0 ± 0.3 mm, in support of the nominal value. An r.m.s. slope error of 7 µrad was also obtained from this analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of multiferroic behavior on flakes-like BiFeO{sub 3}

In present work, multiferroic BiFeO{sub 3} was synthesized by hydrothermal route. The rhombohedral structure was confirmed X-ray diffraction pattern and data fitted with Reitveld refinement using Full-Prof software suite. SEM micrograph shows flake like morphology. Frequency and temperature dependence of dielectric constant and dielectric loss were studied and detected enhancement in dielectric constant. The magnetic measurement indicates antiferromagnetic nature of BFO. P-E curve shows ferroelectic hysteresis loop with remanent polarization (2Pr) 0.3518 µC/cm{sup 2}. The dielectric anomaly observed near T{sub N} can be assigned to magnetoelectric coupling which is useful in device application.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamic volume vs respiratory correlated 4DCT for motion assessment in radiation therapy simulation

Purpose: Conventional (i.e., respiratory-correlated) 4DCT exploits the repetitive nature of breathing to provide an estimate of motion; however, it has limitations due to binning artifacts and irregular breathing in actual patient breathing patterns. The aim of this work was to evaluate the accuracy and image quality of a dynamic volume, CT approach (4D{sub vol}) using a 320-slice CT scanner to minimize these limitations, wherein entire image volumes are acquired dynamically without couch movement. This will be compared to the conventional respiratory-correlated 4DCT approach (RCCT). Methods: 4D{sub vol} CT was performed and characterized on an in-house, programmable respiratory motion phantom containing multiple geometric and morphological ''tumor'' objects over a range of regular and irregular patient breathing traces obtained from 3D fluoroscopy and compared to RCCT. The accuracy of volumetric capture and breathing displacement were evaluated and compared with the ground truth values and with the results reported using RCCT. A motion model was investigated to validate the number of motion samples needed to obtain accurate motion probability density functions (PDF). The impact of 4D image quality on this accuracy was then investigated. Dose measurements using volumetric and conventional scan techniques were also performed and compared. Results: Both conventional and dynamic volume 4DCT methods were capable of estimating the programmed displacement of sinusoidal motion, but patient breathing is known to not be regular, and obvious differences were seen for realistic, irregular motion. The mean RCCT amplitude error averaged at 4 mm (max. 7.8 mm) whereas the 4D{sub vol} CT error stayed below 0.5 mm. Similarly, the average absolute volume error was lower with 4D{sub vol} CT. Under irregular breathing, the 4D{sub vol} CT method provides a close description of the motion PDF (cross-correlation 0.99) and is able to track each object, whereas the RCCT method results in a significantly different PDF from the ground truth, especially for smaller tumors (cross-correlation ranging between 0.04 and 0.69). For the protocols studied, the dose measurements were higher in the 4D{sub vol} CT method (40%), but it was shown that significant mAs reductions can be achieved by a factor of 4-5 while maintaining image quality and accuracy. Conclusions: 4D{sub vol} CT using a scanner with a large cone-angle is a promising alternative for improving the accuracy with which respiration-induced motion can be characterized, particularly for patients with irregular breathing motion. This approach also generates 4DCT image data with a reduced total scan time compared to a RCCT scan, without the need for image binning or external respiration signals within the 16 cm scan length. Scan dose can be made comparable to RCCT by optimization of the scan parameters. In addition, it provides the possibility of measuring breathing motion for more than one breathing cycle to assess stability and obtain a more accurate motion PDF, which is currently not feasible with the conventional RCCT approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

{sup 18}F-sodium fluoride positron emission tomography assessed microcalcifications in culprit and non-culprit human carotid plaques

Background: {sup 18}F-NaF positron emission tomography (PET) targets microcalcifications. We compared in vitro microPET assessed {sup 18}F-NaF uptake between culprit and non-culprit human carotid plaques. Furthermore, we compared {sup 18}F-NaF uptake with calcification visualized on microcomputed tomography (microCT). Methods: Carotid plaques from stroke patients undergoing surgery were incubated in {sup 18}F-NaF and scanned using a microPET and a microCT scan. The average PET assessed {sup 18}F-NaF uptake was expressed as percentage of the incubation dose per gram (%Inc/g). {sup 18}F-NaF PET volume of interest (VOI) was compared with CT calcification VOI. Results: 23 carotid plaques (17 culprit, 6 non-culprit) were included. The average {sup 18}F-NaF uptake in culprit carotid plaques was comparable with the uptake in non-culprit carotid plaques (median 2.32 %Inc/g [IQR 1.98 to 2.81] vs. median 2.35 %Inc/g [IQR 1.77 to 3.00], P = 0.916). Only a median of 10% (IQR 4 to 25) of CT calcification VOI showed increased {sup 18}F-NaF uptake, while merely a median of 35% (IQR 6 to 42) of {sup 18}F-NaF PET VOI showed calcification on CT. Conclusions: {sup 18}F-NaF PET represents a different stage in the calcification process than CT. We observed a similar PET assessed {sup 18}F-NaF uptake and pattern in culprit and non-culprit plaques of high-risk patients, indicating that this method may be of more value in early atherosclerotic stenosis development. [French] French Abstract: Contexte: La tomographie par émission de positons (TEP) au {sup 18}F-NaF marque les micro-calcifications. Nous avons comparé in vitro les plaques carotidiennes humaines responsable d’accident vasculaire cérébrales marquées au {sup 18}F-NaF avec une microTEP et leur calcification au moyen d’un microCT Méthodes: Les plaques carotidiennes de patients victimes d’un accident vasculaire cérébral qui ont bénéficié d’ une intervention chirurgicale ont été incubées dans du {sup 18}F-NaF et imagées avec une microTEP et un microCT. Le pourcentage d’absorption moyen de {sup 18}F-NaF par gr de tissu (% Inc/g) ont été comparées au volume d’intérêt (VOI) des calcifications mesurées par CT. Résultats: 23 plaques carotidiennes (17 responsables d’un AVC et 6 non responsables) ont été incluses. Le % moyen d’absorption de {sup 18}F-NaF dans les plaques carotidiennes responsables furent comparable à l’absorption dans les plaques non responsables (2,32% Inc/g vs 2,35% Inc/g , p = 0,916). Dix pourcent seulement des calcifications visualisées par CT démontrèrent une augmentation d’absorption de {sup 18}F-NaF et 35% des plaques montrant une absorption de {sup 18}F-NaF PET VOI démontrèrent des calcifications au CT. Conclusions: L’imagerie de l’absorption de {sup 18}F-NaF par tomographie à positrons représente un processus physiopathologique différent de l’imagerie des calcifications par CT. L’absorption du {sup 18}F-NaF par les plaques responsables et non responsables d’accidents vasculaire cérébraux pourrait s’avérer utile dans le diagnostic précoce des sténoses athéromateuses. [Spanish] Spanish Abstract: Antecedentes: La tomografía por emisión de positrones (PET) con {sup 18}F-floruro de sodio ({sup 18}F-NaF) demuestra microcalcificaciones. En este estudio, comparamos la captación de {sup 18}F-NaF entre placas carotideas culpables y no culpables valorada con microPET in vitro. Además, comparamos la captación de {sup 18}F-NAF con las calcificaciones detectadas por microtomografía computada (microCT). Métodos: Placas carotídeas de pacientes postoperados que sufrieron de un evento vascular cerebral fueron incubadas en 18-NaF y escaneadas usando microPET y microCT. El promedio de la captación fue expresado como porcentaje de la dosis de incubación por gramo (%Inc/gr). El volumen de interés (VOI) del PET {sup 18}F-NaF se comparó con el VOI de calcificación por CT. Resultados: Se incluyeron 23 placas carotídeas (17 culpables y 6 no culpables). El promedio de la captación de {sup 18}F-NaF en placas carotídeas culpable fue comparable al de las placas no culpables. (mediana 2.32%Inc/gr [IQR1.98-2.81] vs. mediana 2.35%Inc/gr [IQR1.77-3], p=.916). Solo una mediana de 10% (IQR 4-25) del VOI en CT mostró un aumento en la captación de {sup 18}F-NaF, mientras una mediana de 35% (IQR 6-42) del VOI de PET {sup 18}F-NaF mostró calcificación en CT. Conclusiones: La tomografía por emisión de positrones con {sup 18}F-NaF evalúa una etapa distinta en el proceso de calcificación que la CT. El patrón de captación de {sup 18}F-NaF que observamos en este estudio fue similar entre placas culpables y no culpables de pacientes de alto riesgo, lo cual indica que este método puede ser de mayor valor en el desarrollo temprano de la estenosis ateroesclerótica. [Chinese] Chinese Abstract: 背景: F18 氟化钠正电子发射断层扫描 (PET) 可用于检测微钙化。我们使用微型 PET 来评估病人体外 F18 氟化钠在颈动脉罪犯和非罪犯斑块之间的的摄取区别。此外, 我们还将 F18 氟化钠的摄取与 microCT 扫描检测的钙化进行对比。 方法: 将接受手术的中风患者的颈动脉斑块在 F18 氟化钠中培养并用 microPE 和 microCT 进行扫描。PET 对 F18 氟化钠的平均摄取率表示为每克培养剂量的百分比。F18 氟化钠 PET 中的感兴趣区域和 CT 钙化图像中的感兴趣区域 (VOI) 进行比较。 结果: 一共有 23个颈动脉斑块, 其中 17个罪犯斑块和 6个非罪犯斑块。罪犯和非罪犯颈动脉斑块的 F18 氟化钠的平均摄取率无明显差异 (中值 2.32 % Inc/g [IQR 1.98-2.81] vs. 中值2.35 % Inc/g [IQR 1.77-3.00], p = 0.916)。仅中值为10% [IQR 4-25] 的 CT 钙化 VOI 显示有F18氟化钠的摄取增加, 中值为 35%[IQR 6-42] 的 F18 氟化钠 PET VOI 显示有CT 上的钙化。 结论: 相较于 CT, F18 氟化钠 PET 展现了钙化过程中的一个不同阶段。在高危病人中, 我们观察到罪犯和非罪犯斑块具有类似的 PET F18 氟化钠摄取和模式, 表明该方法可能在早期动脉粥样硬化狭窄发展中具有更高的价值。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-169: A Periodic Quality Assurance Program for a Spot-Scanning Proton Treatment Facility

Purpose: To develop daily and monthly quality assurance (QA) programs in support of a new spot-scanning proton treatment facility using a combination of commercial and custom equipment and software. Emphasis was placed on efficiency and evaluation of key quality parameters. Methods: The daily QA program was developed to test output, spot size and position, proton beam energy, and image guidance using the Sun Nuclear Corporation rf-DQA™3 device and Atlas QA software. The program utilizes standard Atlas linear accelerator tests repurposed for proton measurements and a custom jig for indexing the device to the treatment couch. The monthly QA program was designed to test mechanical performance, image quality, radiation quality, isocenter coincidence, and safety features. Many of these tests are similar to linear accelerator QA counterparts, but many require customized test design and equipment. Coincidence of imaging, laser marker, mechanical, and radiation isocenters, for instance, is verified using a custom film-based device devised and manufactured at our facility. Proton spot size and position as a function of energy are verified using a custom spot pattern incident on film and analysis software developed in-house. More details concerning the equipment and software developed for monthly QA are included in the supporting document. Thresholds for daily and monthly tests were established via perturbation analysis, early experience, and/or proton system specifications and associated acceptance test results. Results: The periodic QA program described here has been in effect for approximately 9 months and has proven efficient and sensitive to sub-clinical variations in treatment delivery characteristics. Conclusion: Tools and professional guidelines for periodic proton system QA are not as well developed as their photon and electron counterparts. The program described here efficiently evaluates key quality parameters and, while specific to the needs of our facility, could be readily adapted to other proton centers.

60 APPLIED LIFE SCIENCES↗

TH-CD-207A-04: Optimized Respiratory Gating for Abnormal Breathers in Pancreatic SBRT

Purpose: Pancreatic SBRT is uniquely challenging due to both the erratic/unstable motion of the pancreas and the close proximity of the radiosensitive small bowel. Respiratory gating can mitigate this effect, but the irregularity of motion severely affects traditional phase-based gating. The purpose of this study was to analyze real-time motion data of pancreatic tumors to optimize the efficacy and accuracy of respiratory gating, with the overall goal of enabling dose escalated pancreatic SBRT. Methods: Fifteen pancreatic SBRT patients received 30–33 Gy in 5 fractions on a Varian TrueBeam STx unit. Abdominal compression was used to reduce the amplitude of tumor motion, and daily cone-beam computed tomography (CBCT) scans were acquired prior to each treatment for target localization purposes. For this study, breathing data (phase and amplitude) were collected during each CBCT scan using Varian’s Real-Time Position Management system. An in-house template matching technique was used to track the superior-inferior motion of implanted fiducial markers in CBCT projection images. Using tumor motion and breathing data, phase-based or amplitude-based respiratory gating was simulated for all 75 fractions, targeting either end-exhalation or end-inhalation phases of breathing. Results: For the average patient, gating at end-exhalation offered the best reductions in effective motion for equal duty cycles. However, optimal central phase angle varied widely (range: 0–92%, mean±SD: 49±12%), and phase-based gating windows typically associated with end-exhalation (i.e., “30–70%”) were rarely ideal. Amplitude-based gating significantly outperformed phase-based gating, with average effective ranges for amplitude-based gating 25% lower than phase-based gating ranges (as much as 73% lower). Amplitude-based gating was consistently better suited to accommodate abnormal breathing patterns. For both phase-based and amplitude-based gating, end-exhalation provided significantly better results than end-inhalation. Conclusion: Amplitude-based gating reliably outperformed phase-based gating, and end-exhalation was more suitable than end-inhalation. These results will be used to guide future dose-escalation trials. Research funding provided by Varian Medical Systems to Miften and Jones.

60 APPLIED LIFE SCIENCES↗

Probing free carrier plasmons in doped semiconductors using spatially resolved electron energy loss spectroscopy

We report spatially resolved measurements of free carrier collective excitations in a doped semiconductor. Using ~10 meV resolution electron energy loss spectroscopy (EELS) in an electron microscope with Å spatial resolution, we identify both surface and bulk carrier plasmons at infrared energies in a freestanding film of indium tin oxide (ITO). The interference patterns of long wavelength propagating surface carrier plasmons are revealed using spatially resolved EELS, from which we extract a dispersion relation. We further show that the energies of these plasmons vary near the surfaces and grain boundaries of the film due to band bending. Modeling based on dielectric theory agrees very well with experimental results. Finally, carrier plasmons in amorphous and crystalline ITO films are compared. These results should also be helpful for understanding the free carrier plasmons in other doped semiconductors in nanoscale volumes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-424: Feasibility of 3D Printed Radiological Equivalent Customizable Tissue Like Materials

Purpose: To investigate the feasibility of 3D printing CT# specific radiological equivalent tissue like materials. Methods: A desktop 3D printer was utilized to create a series of 3 cm x 3 cm x 2 cm PLA plastic blocks of varying fill densities. The fill pattern was selected to be hexagonal (Figure 1). A series of blocks was filled with paraffin and compared to a series filled with air. The blocks were evaluated with a “GE Lightspeed” 16 slice CT scanner and average CT# of the centers of the materials was determined. The attenuation properties of the subsequent blocks were also evaluated through their isocentric irradiation via “TrueBeam” accelerator under six beam energies. Blocks were placed upon plastic-water slabs of 4 cm in thickness assuring electronic equilibrium and data was collected via Sun Nuclear “Edge” diode detector. Relative changes in dose were compared with those predicted by Varian “Eclipse” TPS. Results: The CT# of 3D printed blocks was found to be a controllable variable. The fill material was able to narrow the range of variability in each sample. The attenuation of the block tracked with the density of the total fill structure. Assigned CT values in the TPS were seen to fall within an expected range predicted by the CT scans of the 3D printed blocks. Conclusion: We have demonstrated that it is possible to 3D print materials of varying tissue equivalencies, and that these materials have radiological properties that are customizable and predictable.

60 APPLIED LIFE SCIENCES↗

Deviation from threshold model in ultrafast laser ablation of graphene at sub-micron scale

We investigate a method to measure ultrafast laser ablation threshold with respect to spot size. We use structured complex beams to generate a pattern of craters in CVD graphene with a single laser pulse. A direct comparison between beam profile and SEM characterization allows us to determine the dependence of ablation probability on spot-size, for crater diameters ranging between 700 nm and 2.5 μm. We report a drastic decrease of ablation probability when the crater diameter is below 1 μm which we interpret in terms of free-carrier diffusion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature-dependent XRD, IR, magnetic, SEM and TEM studies of Jahn–Teller distorted NiCr{sub 2}O{sub 4} powders

In the present work we report detailed structural, magnetic and phonon properties of NiCr{sub 2}O{sub 4} powders synthesized via a simple coprecipitation method. Temperature-dependent XRD as well as temperature-dependent IR studies reveal that cubic to tetragonal phase transition is lowered due to size effects. Observed changes in the IR spectra indicate that the paramagnetic–ferrimagnetic phase transition taking place at 74 K is related to further lowering of symmetry to orthorhombic system. Assignment of modes was proposed and factor group analyses in three possible symmetries were carried out. Our results show strong anomalies due to the Jahn–Teller tetragonal distortion and weak due to the orthorhombic distortion and onset of collinear ferrimagnetic order. Shifts of wavenumbers observed below 31 K, where the onset of antiferromagnetic ordering occurs, were attributed to spin–phonon interactions. - Graphical abstract: XRD pattern of NiCr{sub 2}O{sub 4} sample synthesized via a coprecipitation method followed by calcination at 1000 {sup o}C. - Highlights: • NiCr{sub 2}O{sub 4} starts to crystallize near 750 °C. • Coexistence of cubic and tetragonal phases of NiCr{sub 2}O{sub 4} was revealed. • Temperature of the Jahn–Teller distortion is lowered due to the size effects. • Evidences of tetragonal and orthorhombic distortions were found. • Weak spin–phonon interactions were evidenced.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray diffraction, FTIR, UV-VIS and SEM studies on chromium (III) complexes

Five Chromium (III) complexes have been prepared using Schiff base ligands which derived from benzoin and five different amino acids (H{sub 2}N-R). Samples were characterized by XRD, FTIR, UV-VIS and SEM method. X-Ray diffraction pattern analyzed that all chromium (III) complexes have hexagonal structure and crystalline, in nature, using Bruker D8 Advance instrument. Using VERTAX 70, FTIR spectroscopy reveals that Samples have (C=N), (C-O), (M-N) and (M-O) bonds in the range of 4000-400cm{sup −1}. UV-VIS spectroscopy give information that samples absorb the visible light which is in the range of 380-780nm. For this, Lambda 960 spectrometer used. SEM is designed for studying of the solid objects, using JEOL JSM 5600 instrument.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radiative detached divertor with acceptable separatrix Z eff

The feasibility study is performed for the radiative detached divertor (RDD) concept, which characterizes a variety of detached plasmas with impurity amounts providing the highest levels of divertor radiation without X-point MARFE (XPM), based on a set of restrictive criteria for the leading plasma parameters (LPPs) including, e.g., tolerable peak power loads below 1 MW/m2, low separatrix densities, allowable impurity concentrations, and acceptable Z eff values for a DIII-D like tokamak. For this, extensive simulations with the 2-D edge plasma transport code were done scanning the deuterium and impurity inventories practically for all impurity elements from beryllium to neon and the analysis of LPP variations in these scans is presented. It is shown that, for a given D inventory, the total radiation fraction with an increase in the impurity inventory reaches a flat top level, f rad = 0.85 ± 0.01, whereas the higher f rad corresponds to XPM. This critical fraction is the same for all elements and values of the D inventory. Successful RDD solutions with a flat top radiation meeting all ad hoc LPP criteria are found for some elements. Boron and nitrogen are shown to be the most promising elements for seeding, since they are capable of providing alone the successful RDD at the lowest concentrations. Several important effects on impurity radiation are considered including: cross-field impurity transport in regions with strong temperature gradients, multi-species thermal force, charge-exchange of impurity ions with D atoms originating from recombination, impurity entrainment by parallel flows, flows caused by inner/outer divertor asymmetries, and Mach ∼ 1 flows reached inside radiation-ionization fronts. The impurity radiation profiles of various elements are analyzed suggesting three patterns differing in the radiation front position with respect to the D ionization source. The modeled relocation of D from the pedestal into divertor regions; an enhanced pedestal enrichment for impurities with high first ionization potential; and RDD capability of confining inside the divertors the large D inventories as neutral atoms, are considered as effects of increasing impurity inventory. The responses of a flat-top RDD to the input parameters variation are studied. For example, dependencies of LPPs on the input power increase, which express the sharp and even bifurcation transitions between two distinct branches corresponding to the detached and attached divertors, are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Model study of the energy dependence of the correlation between anisotropic flow and the mean transverse momentum in Au + Au collisions

A hybrid model that employs the hadron-string transport model UrQMD and the (3+1)-dimensional relativistic viscous hydrodynamic code vHLLE, is used to investigate the beam energy dependence of the correlation coefficient ρ(v$^{2}_{2}$,[p T ]) between the average transverse momentum [p T ] of hadrons emitted in an event and the square of the anisotropic flow coefficient v$^{2}_{2}$. For Au+Au collisions, the model predicts characteristic patterns for the energy and event-shape dependence of the variances for [p T ] and v$^{2}_{n}$ [Var([p T ] and Var(v$^{2}_{2}$)], and the covariance of v$^{2}_{n}$ and [p T ][cov(v$^{2}_{2}$,[p T ])], consistent with the attenuation effects of the specific shear viscosity η/s. Here in contrast, ρ(v$^{2}_{2}$,[p T ]) is predicted to be insensitive to the beam energy but sensitive to the initial-state geometry of the collisions. These observations suggest that a precise set of measurements for Var([p T ]), Var(v$^{2}_{2}$), cov(v$^{2}_{2}$,[p T ]) and ρ(v$^{2}_{2}$,[p T ]) as a function of beam energy and event shape, could serve to constrain better the eccentricities and their fluctuations over the entire span of beam energies, and consequently aid precision extraction of the temperature and baryon chemical-potential dependence of η/s from the wealth of Au+Au data obtained in the RHIC beam energy scan.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crosslinked Polyacrylamide Composite Hydrogels Impregnated with Fly Ash: Synthesis, Characterization and Their Application as Fractures Sealant for High Water Producing Zones in Oil and Gas Wells

Polymeric hydrogels are designed to serve many purposes in various fields of human endeavor. Herein, crosslinked polyacrylamide (PAM) composite hydrogels impregnated with coal fly ash (CFA) were synthesized, characterized and tested as fracture sealing agents in high water producing permeable zones in petroleum industry. The concept of utilizing CFA as an inorganic additive in the matrix of hydrogel emanates from the fact that CFA constitutes majorly alumina and silica. Both chemical oxides can induce the CFA to promote the inherent properties of hydrogel. Polyethyleneimine (PEI) was chosen as the crosslinking agent. Neat PAM/PEI hydrogel and PAM/PEI–CFA hydrogels at various CFA loadings (0.5, 1 and 2 wt%) were synthesized via a transamidation reaction pathway. The developed hydrogels were characterized by hybrid rheometer, FTIR, SEM and XRD instruments. Rheological results reveal that the PAM/PEI–CFA composite hydrogels embedded with various CFA quantities were more elastic than the neat PAM/PEI hydrogel, indicating the dispersion and reinforcing effect of CFA. The functional groups of these hydrogels were confirmed by the FTIR while SEM analysis show that the surface micrographs of neat PAM/PEI hydrogel and PAM/PEI–CFA1 hydrogel were porous in several regions. In contrast, the micrographs of PAM/PEI–CFA2 and PAM/PEI–CFA3 hydrogels demonstrated dense and “net-like” structural patterns. Further, XRD analysis revealed that CFA impregnation has a significant effect on the bulk structural properties of the fabricated hydrogels. The swelling rates of these hydrogels were determined by the gravimetric method and their diffusion parameters evaluated using Fickian diffusion and Schott-order kinetic models. Efficacy of the PAM/PEI–CFA composite hydrogel as fractures sealant in oil and gas wells was conducted at a typical reservoir temperature, 90 °C, and the outcome demonstrated considerable sealing potency.

36 MATERIALS SCIENCE↗

New water soluble heterometallic complex showing unpredicted coordination modes of EDTA

A mesoporous 3D polymeric complex (I) having formula ([Zr(IV)O-μ{sup 3}-(EDTA)Fe(III)OH]·H{sub 2}O){sub n} has been crystallized and characterized by various techniques. Single-crystal X-ray diffraction analysis revealed that complex (I) crystallized in chiral monoclinic space group Cc (space group no. 9) with unexpected coordination modes of EDTA and mixture of two transition metal ions. In this complex, the coordination number of Zr(IV) ion is seven where four carboxylate oxygen atoms, two nitrogen atoms, one oxide atom are coordinating with Zr(IV). Fe(III) is four coordinated and its coordination environment is composed of three different carboxylic oxygen atoms from three different EDTA and one oxygen atom of –OH group. The structure consists of 4-c and 16-c (2-nodal) net with new topology and point symbol for net is (3{sup 36}·4{sup 54}·5{sup 30})·(3{sup 6}). TGA study and XRPD pattern showed that the coordination polymer is quite stable even after losing water molecule and –OH ion. Quenching behavior in fluorescence of ligand is observed by complexation with transition metal ions is due to n–π⁎ transition. The SEM micrograph shows the morphology of complex (I) exhibits spherical shape with size ranging from 50 to 280 nm. The minimum N{sub 2} (S{sub BET}=8.7693 m{sup 2}/g) and a maximum amount of H{sub 2} (high surface area=1044.86 m{sup 2}/g (STP)) could be adsorbed at 77 K. From DLS study, zeta potential is calculated i.e. −7.94 shows the negative charges on the surface of complex. Hirshfeld surface analysis and fingerprint plots revealed influence of weak or non bonding interactions in crystal packing of complex. - Graphical abstract: The complex (I) crystallized with unexpected coordination modes of EDTA having 4-c, 16-c net with new topology and point symbol is (3{sup 36}·4{sup 54}·5{sup 30})·(3{sup 6}). TGA study and XRPD pattern proved its stability with high preference of H{sub 2} uptake by complex. - Highlights: • 3D complex having unexpected coordination modes of EDTA with Zr(IV) and Fe(III). • The structure consists of 4-c and 16-c (2-nodal) net with new topology. • Reasonable S{sub BET} (8.7693 m{sup 2}/g) but high H{sub 2} uptake (1044.86 m{sup 2}/g) due to limited pore size. • Quenching behavior due to n–π⁎ transition by complexation with transition metal ions. • From DLS study, zeta potential value is −7.94.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗