Performance of Au transmission photocathode on a microchannel plate detector

X-ray framing cameras, employing microchannel plates (MCPs) for detection and signal amplification, play a key role in research in high-energy-density physics. These instruments convert radiographic x-rays into electrons produced by plasma during such experiments into electrons that are amplified in the channels and then detected by a phosphor material. The separation of detection from signal amplification offers potential improvements in sensitivity and noise properties. We have implemented a suspended Au transmission photocathode (160 A thick) on a MCP and are evaluating it using a 1.5 keV Al K{alpha} x-ray source. We find an approximately twofold increase in the ratio of detected events to incident photons when the photocathode-to-MCP voltage difference is sufficiently large. Our calculations indicate that this increase is probably caused by a combination of signal produced by the photocathode and an increase in the efficiency of detection of x-rays that reach the MCP surface through modification of the local electric field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ positioning of a few hundred micrometer-sized cleaved surfaces for soft-x-ray angle-resolved photoemission spectroscopy by use of an optical microscope

A method to position samples with small cleaved regions has been developed to be applied to the angle-resolved photoemission spectroscopy (ARPES) which uses soft-x-ray synchrotron radiation focused down to 160x180 {mu}m{sup 2}. A long-working-distance optical microscope is used for the sample observation. A selected region on a sample can be optimally set at the position of measurements, which is realized by the spatial resolution of the photoelectron analyzer. Using this method, electronic band dispersions of bulk silicon have been measured by ARPES for a partially cleaved region with a size of {approx}200x500 {mu}m{sup 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of the accuracy of plasma shape reconstruction by the Cauchy condition surface method in JT-60SA

For the purpose of stable plasma equilibrium control and detailed analysis, it is essential to reconstruct an accurate plasma boundary on the poloidal cross section in tokamak devices. The Cauchy condition surface (CCS) method is a numerical approach for calculating the spatial distribution of the magnetic flux outside a hypothetical surface and reconstructing the plasma boundary from the magnetic measurements located outside the plasma. The accuracy of the plasma shape reconstruction has been assessed by comparing the CCS method and an equilibrium calculation in JT-60SA with a high elongation and triangularity of plasma shape. The CCS, on which both Dirichlet and Neumann conditions are unknown, is defined as a hypothetical surface located inside the real plasma region. The accuracy of the plasma shape reconstruction is sensitive to the CCS free parameters such as the number of unknown parameters and the shape in JT-60SA. It is found that the optimum number of unknown parameters and the size of the CCS that minimizes errors in the reconstructed plasma shape are in proportion to the plasma size. Furthermore, it is shown that the accuracy of the plasma shape reconstruction is greatly improved using the optimum number of unknown parameters and shape of the CCS, and the reachable reconstruction errors in plasma shape and locations of strike points are within the target ranges in JT-60SA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pioneer WEC concept design report

The "Pioneer WEC" project is targeted at developing a wave energy generator for the Coastal Surface Mooring (CSM) system within the Ocean Observatories Initiative (OOI) Pioneer Array. The CSM utilizes solar photovoltaic and wind generation systems, along with rechargeable batteries, to power multiple sensors on the buoy and along the mooring line. This approach provides continuous power for essential controller functions and a subset of instruments, and meets the full power demand roughly 70% of the time. Sandia has been tasked with designing a wave energy system to provide additional electrical power and bring the CSM up-time for satisfying the full-power demand to 100%. This project is a collaboration between Sandia and Woods Hole Oceanographic Institution (WHOI), along with Evergreen Innovations, Monterey Bay Aquarium Research Institute (MBARI), Eastern Carolina University (ECU), Johns Hopkins University (JHU), and the National Renewable Energy Laboratory (NREL). This report captures Phase I of an expected two phase project and presents project scoping and concept design results.

16 TIDAL AND WAVE POWER↗

Processing system of jaws tomograms for pathology identification and surgical guide modeling

The aim of the study is to create an image processing system, which allows dentists to find pathological resorption and to build surgical guide surface automatically. X-rays images of jaws from cone beam tomography or spiral computed tomography are the initial data for processing. One patient’s examination always includes up to 600 images (or tomograms), that’s why the development of processing system for fast automation search of pathologies is necessary. X-rays images can be useful not for only illness diagnostic but for treatment planning too. We have studied the case of dental implantation – for successful surgical manipulations surgical guides are used. We have created a processing system that automatically builds jaw and teeth boundaries on the x-ray image. After this step, obtained teeth boundaries used for surgical guide surface modeling and jaw boundaries limit the area for further pathologies search. Criterion for the presence of pathological resorption zones inside the limited area is based on statistical investigation. After described actions, it is possible to manufacture surgical guide using 3D printer and apply it in surgical operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DOE Plasma Science Center - Predictive Control of Plasma Kinetics: Multi-Phase and Bounded Systems (Final Report DE-SC0001939)

Low temperature plasmas (LTPs) are the plasmas of electron-volt (eV) physics and eV technologies. LTPs have characteristic electron temperatures of a few eV and fractional ionizations that are typically small. Since LTPs have electron temperatures commensurate with the threshold energies of excited states in neutral atoms and molecules, power transfer from electrons to these atoms and molecules efficiently produces activated species (e.g., radicals, excited states, photons). Acceleration of ions in the sheaths of LTPs to energies of tens to hundreds of eV enable activation of surface modifying processes – sputtering, etching, deposition. With such properties, LTPs are often and beneficially used in technological devices, ranging from etching and deposition in microelectronics and solar cell fabrication, to hardening of surgical instruments. LTPs harbor fundamental science issues that are intellectually challenging and rewarding. At the same time, there are enormous societal benefits that are enabled by LTPs. The entire present-day and future information technology infrastructure owes its very existence to LTPs. Renewable energy sources, such as solar cell arrays, could not be economically produced in the absence of deposition and etching by LTPs. In acknowledgment of the importance of LTPs, the DOE Office of Fusion Energy Sciences supported the Plasma Science Center for Predictive Control of Plasma Kinetics: Multi-Phase and Bounded Systems from August 2009 to July 2021, consisting of an initial 5-year grant, 3 funded extensions and 2 no-cost extensions. This is the final report of the Center in which the productivity of the Center is discussed in terms of publications, impact and personnel. High-lights of the research performed in the Center are provided.

36 MATERIALS SCIENCE↗

Overview of the beam emission spectroscopy diagnostic system on the National Spherical Torus Experiment

A beam emission spectroscopy (BES) system has been installed on the National Spherical Torus Experiment (NSTX) to study ion gyroscale fluctuations. The BES system measures D{sub {alpha}} emission from a deuterium neutral heating beam. The system includes two optical views centered at r/a{approx_equal}0.45 and 0.85 and aligned to magnetic field pitch angles at the neutral beam. f/1.5 collection optics produce 2-3 cm spot sizes at the neutral beam. The initial channel layout includes radial arrays, poloidal arrays, and two-dimensional grids. Radial arrays provide coverage from r/a{approx_equal}0.1 to beyond the last-closed flux surface. Photodetectors and digital filters provide high-sensitivity, low-noise measurements at frequencies of up to 1 MHz. The BES system will be a valuable tool for investigating ion gyroscale turbulence and Alfven/energetic particle modes on NSTX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods for lipid nanostructure investigation at neutron and synchrotron sources

A lipid membrane is a main component of biological membranes. Contemporary bionanotechnologies use phospholipids and ceramides as basic components of drugs and cosmetic preparations. Phospholipids-based nanoparticles are used as drug carriers. Effective development of bionanotechnologies in Russia calls for creation of physical methods to diagnose the particle nanostructure which would be promising for application in pharmacology. Radiation with wavelengths of 1–10 Å is an adequate instrument for detecting the nanostructure of lipid bi- and monolayers. The review deals with methods that apply neutron scattering and synchrotron radiation for studying nanostructures of lipid membranes, phospholipid nanoparticles, and phospholipid monolayers on a water surface by techniques of diffraction, small-angle scattering, and reflectometry. The importance of the mutually complementary application of neutron and synchrotron radiation for solving urgent problems of membrane biophysics, microbiology, dermapharmacology, and bionanotechnologies is demonstrated by particular examples of studies of phospholipid membranes and ceramide-based membranes. The efficiency of development and application of new methods for solving urgent problems of biophysics is shown. The review is written on the basis of results obtained over the period of 1999–2010 at the Joint Institute for Nuclear Research (JINR) Laboratory of Neutron Physics in collaboration with the Pharmaceutical Departments of universities of France (Paris-Sud, Chatenay Malabry) and Germany (Martin Luther University, Halle). The experiments were performed at various European and Russian neutron and synchrotron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of confocal laser microscopy for monitoring mesh implants in herniology

The state of the surface of mesh implants and their encapsulation region in herniology is investigated by laser confocal microscopy. A correlation between the probability of developing relapses and the size and density of implant microdefects is experimentally shown. The applicability limits of differential reverse scattering for monitoring the post-operation state of implant and adjacent tissues are established based on model numerical experiments. (optical technologies in biophysics and medicine)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wireless Monitoring Study in the Meuse / Haute-Marne Underground Research Laboratory, France - 12046

Two types of wireless transmission systems using ultra low frequency (8.5 kHz) were developed and used in the Callovo-Oxfordian argillites layer in the Meuse / Haute-Marne Underground Research Laboratory (CMHM URL) in France. Short-range and mid-range transmission antennas received data transmitted from 25 m to 50 m away. From the results of two series of tests, it is clear that transmission is practical when the received voltage is larger than the received noise. However, it is also clear that wireless transmission in the CMHM URL gallery is affected by the electromagnetic noise level and steel components, and the maximum transmission distance depends on the S/N ratio. The mid-range transmission antenna achieved a transmission distance of 240 m in the surface test, where the electromagnetic noise level was small and there was no environmental attenuation. The short-range transmission antenna achieved a transmission distance of 25 m in the surface test and in the CMHM URL gallery. As the clay layer of the CMHM URL had little effect on the attenuation of the electromagnetic field, transmission over 200 m might be possible in the CMHM URL when the electromagnetic noise level is small enough and there are no significant factors enhancing attenuation. But in reality, the possible transmission distance was around 50 m. In order to show the transmitter's ability, it is preferable to keep some distance between steel components and the transmitter. The most effective way to use this transmitter is to put it in a borehole drilled from a gallery to outside of a gallery around 10 m length. In this way, it might be possible to avoid almost of all the influence of steel components. For the position of receiver, the recommendation is the same as for the transmitter. That is, place the receiver where the incoming signal from the transmitter suffers little attenuation from steel components. Therefore, the option of implementing a receiving antenna in a borehole is required. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The soft x-ray instrument for materials studies at the linac coherent light source x-ray free-electron laser

The soft x-ray materials science instrument is the second operational beamline at the linac coherent light source x-ray free electron laser. The instrument operates with a photon energy range of 480-2000 eV and features a grating monochromator as well as bendable refocusing mirrors. A broad range of experimental stations may be installed to study diverse scientific topics such as: ultrafast chemistry, surface science, highly correlated electron systems, matter under extreme conditions, and laboratory astrophysics. Preliminary commissioning results are presented including the first soft x-ray single-shot energy spectrum from a free electron laser.

43 PARTICLE ACCELERATORS↗

Atomic force microscopy deep trench and sidewall imaging with an optical fiber probe

We report a method to measure critical dimensions of micro- and nanostructures using the atomic force microscope (AFM) with an optical fiber probe (OFP). This method is capable of scanning narrow and deep trenches due to the long and thin OFP tip, as well as imaging of steep sidewalls with unique profiling possibilities by laterally tilting the OFP without any modifications of the optical lever. A switch control scheme is developed to measure the sidewall angle by flexibly transferring feedback control between the Z- and Y-axis, for a serial scan of the horizontal surface (raster scan on XY-plane) and sidewall (raster scan on the YZ-plane), respectively. In experiments, a deep trench with tapered walls (243.5 μm deep) and a microhole (about 14.9 μm deep) have been imaged with the orthogonally aligned OFP, as well as a silicon sidewall (fabricated by deep reactive ion etching) has been characterized with the tilted OFP. Moreover, the sidewall angle of TGZ3 (AFM calibration grating) was accurately measured using the switchable scan method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Product gas evolution above planar microstructured model catalysts--A combined scanning mass spectrometry, Monte Carlo, and Computational Fluid Dynamics study

The transport and distribution of reaction products above catalytically active Pt microstructures was studied by spatially resolved scanning mass spectrometry (SMS) in combination with Monte Carlo simulation and fluid dynamics calculations, using the oxidation of CO as test reaction. The spatial gas distribution above the Pt fields was measured via a thin quartz capillary connected to a mass spectrometer. Measurements were performed in two different pressure regimes, being characteristic for ballistic mass transfer and diffusion involving multiple collisions for the motion of CO{sub 2} product molecules between the sample and the capillary tip, and using differently sized and shaped Pt microstructures. The tip height dependent lateral resolution of the SMS measurements as well as contributions from shadowing effects, due to the mass transport limitations between capillary tip and sample surface at close separations, were evaluated and analyzed. The data allow to define measurement and reaction conditions where effects induced by the capillary tip can be neglected (''minimal invasive measurements'') and provide a basis for the evaluation of catalyst activities on microstructured model systems, e.g., for catalyst screening or studies of transport effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prediction of Mass Spectral Response Factors from Predicted Chemometric Data for Druglike Molecules

A method is developed for the prediction of mass spectral ion counts of drug-like molecules using in silico calculated chemometric data. Various chemometric data, including polar and molecular surface areas, aqueous solvation free energies, and gas-phase and aqueous proton affinities were computed, and a statistically significant relationship between measured mass spectral ion counts and the combination of aqueous proton affinity and total molecular surface area was identified. In particular, through multilinear regression of ion counts on predicted chemometric data, we find that log{sub 10}(MS ion counts) = –4.824 + c{sub 1}•PA + c{sub 2}•SA, where PA is the aqueous proton affinity of the molecule computed at the SMD(aq)/M06-L/MIDI!//M06-L/MIDI! level of electronic structure theory, SA is the total surface area of the molecule in its conjugate base form, and c{sub 1} and c{sub 2} have values of –3.912 × 10{sup –2} mol kcal{sup –1} and 3.682 × 10{sup –3} Å{sup –2}. On a 66-molecule training set, this regression exhibits a multiple R value of 0.791 with p values for the intercept, c{sub 1}, and c{sub 2} of 1.4 × 10{sup –3}, 4.3 × 10{sup –10}, and 2.5 × 10{sup –6}, respectively. Application of this regression to an 11-molecule test set provides a good correlation of prediction with experiment (R = 0.905) albeit with a systematic underestimation of about 0.2 log units. This method may prove useful for semiquantitative analysis of drug metabolites for which MS response factors or authentic standards are not readily available. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A technique for extending the precision and the range of temperature programmed desorption toward extremely low coverages

In this paper, an improvement of the temperature programmed desorption (TPD) technique is introduced, which facilitates fully automated sampling of TPD spectra with excellent reproducibility, especially useful for extremely low coverages. By averaging many sampled TPD spectra, the range of the TPD technique can be extended toward lower coverages, as well as the quality of the spectra can be improved. This allows for easy extraction of information about the adsorbate-surface bond. A state of the art TPD apparatus with a two chamber setup and a high quality quadrupole mass spectrometer was extended by automated components. These are an automated gas dosing system, ensuring precise dosing of gas, combined with a motor driven sample manipulation unit and a liquid nitrogen cryostat with automatic refilling. In addition all components were controlled by a computer. A large number of TPD cycles could be sampled without the need of interaction of an operator. Here, it is shown for up to more than 400 TPD cycles. This opens a wide range of new interesting applications for the TPD technique, especially in the limit of zero coverage. Here, basic experiments on well known adsorbate systems are shown to view the ability and limit of this approach.

36 MATERIALS SCIENCE↗

The ReactorSTM: Atomically resolved scanning tunneling microscopy under high-pressure, high-temperature catalytic reaction conditions

To enable atomic-scale observations of model catalysts under conditions approaching those used by the chemical industry, we have developed a second generation, high-pressure, high-temperature scanning tunneling microscope (STM): the ReactorSTM. It consists of a compact STM scanner, of which the tip extends into a 0.5 ml reactor flow-cell, that is housed in a ultra-high vacuum (UHV) system. The STM can be operated from UHV to 6 bars and from room temperature up to 600 K. A gas mixing and analysis system optimized for fast response times allows us to directly correlate the surface structure observed by STM with reactivity measurements from a mass spectrometer. The in situ STM experiments can be combined with ex situ UHV sample preparation and analysis techniques, including ion bombardment, thin film deposition, low-energy electron diffraction and x-ray photoelectron spectroscopy. The performance of the instrument is demonstrated by atomically resolved images of Au(111) and atom-row resolution on Pt(110), both under high-pressure and high-temperature conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Airbreathing Laser Propulsion Experiments with 1 {mu}m Terawatt Pharos III Laser: Part 1

This basic research study examines the physics of airbreathing laser propulsion at the extreme flux range of 1-2x10{sup 11} W/cm{sup 2}--within the air breakdown threshold for l {mu}m radiation--using the terawatt PHAROS III neodymium-glass pulsed laser. Six different experimental setups were tested using a 34 mm line focus with 66 {mu}m focal waist, positioned near the flat impulse surface. The first campaign investigated impulse generation with the beam oriented almost normal to the target surface, with energies ranging from 23 to 376 J, and pulses of 5 to 30 ns FWHM. Air breakdown/ plasma dynamics were diagnosed with GOI cameras and color photography. Laser generated impulse was quantified with both vertical pendulums and piezoelectric pressure transducers using the standard performance metric, C{sub M}--the momentum coupling coefficient. Part 1 of this 2-part paper covers Campaign no. 1 results including laser plasma diagnostics, pressure gage and vertical pendulum data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved photoemission apparatus achieving sub-20-meV energy resolution and high stability

The paper describes a time- and angle-resolved photoemission apparatus consisting of a hemispherical analyzer and a pulsed laser source. We demonstrate 1.48-eV pump and 5.92-eV probe measurements at the ⩾10.5-meV and ⩾240-fs resolutions by use of fairly monochromatic 170-fs pulses delivered from a regeneratively amplified Ti:sapphire laser system operating typically at 250 kHz. The apparatus is capable to resolve the optically filled superconducting peak in the unoccupied states of a cuprate superconductor, Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+δ}. A dataset recorded on Bi(111) surface is also presented. Technical descriptions include the followings: A simple procedure to fine-tune the spatio-temporal overlap of the pump-and-probe beams and their diameters; achieving a long-term stability of the system that enables a normalization-free dataset acquisition; changing the repetition rate by utilizing acoustic optical modulator and frequency-division circuit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗