Improved Time-Dependent Seismic Monitoring Systems for Enhanced Geothermal Reservoir Characterization
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
A diagnostic system for characterization of an electron beam or an ion beam includes an electrical conducting disk of refractory material having a circumference, a center, and a Faraday cup assembly positioned to receive the electron beam or ion beam. At least one slit in the disk provides diagnostic characterization of the electron beam or ion beam. The at least one slit is located between the circumference and the center of the disk and includes a radial portion that is in radial alignment with the center and a portion that deviates from radial alignment with the center. The electron beam or ion beam is directed onto the disk and translated to the at least one slit wherein the electron beam or ion beam enters the at least one slit for providing diagnostic characterization of the electron beam or ion beam.
Free space optical communication methods and systems, according to various aspects are described. The methods and systems are characterized by transmission of data through free space with a digitized optical signal acquired using wavelength modulation, and by discrimination between bit states in the digitized optical signal using a spectroscopic absorption feature of a chemical substance.
Generally speaking, the method of the present invention is performed by making various ultrasonic scans at preselected orientations along the length of a material being tested. Data from the scans are then plotted together with various calculated parameters that are calculated from this data. Lines or curves are then fitted to the respective plotted points. Review of these plotted curves allows the location and severity of defects within these sections to be determined and quantified. With this information various other decisions related to how, when or whether repair or replacement of a particular portion of a structure can be made.
DOE/NNSA NA-40 was requested to provide support with consequence management activities following the incident at the Fukushima Dai’ichi Nuclear Power Plant. The response involved the deployment of several DOE/NNSA NA-40 assets to provide specialized capabilities analysts, scientists, doctors, nurses, specialized equipment and systems to characterize the deposition for the protection of the public and the environment. General response activities revolved around the concepts of: predictive modeling; monitoring and data collection from the air and on the ground; assessing the collected data and other relevant information; interpreting the data; and coordinating the communication of the interpreted data to the appropriate stakeholders.
Abstract Not Provided
A Surface Impedance Characterization (SIC) system has been proposed at the 2005 SRF workshop and recently updated as detailed at the 2009 PAC conference. Currently the SIC system can measure samples in a temperature range from 2K to 20K exposed to an RF magnetic flux density of less than 3mT. We report on new results of a BCP etched large grain Nb sample measured with this system as compared with previous results of a BCP etched polycrystalline Nb sample. The design of an upgraded SIC system for use at higher magnetic flux densities is on the way to more efficiently investigate correlations between local material characteristics and associated SRF properties, both for preparation studies of bulk niobium and also new thin film SRF developments.
Redox flow battery systems having a supporting solution that contains Cl.sup.- ions can exhibit improved performance and characteristics. Furthermore, a supporting solution having mixed SO.sub.4.sup.2- and Cl.sup.- ions can provide increased energy density and improved stability and solubility of one or more of the ionic species in the catholyte and/or anolyte. According to one example, a vanadium-based redox flow battery system is characterized by an anolyte having V.sup.2+ and V.sup.3+ in a supporting solution and a catholyte having V.sup.4+ and V.sup.5+ in a supporting solution. The supporting solution can contain Cl.sup.- ions or a mixture of SO.sub.4.sup.2- and Cl.sup.- ions.
Redox flow battery systems having a supporting solution that contains Cl.sup.- ions can exhibit improved performance and characteristics. Furthermore, a supporting solution having mixed SO.sub.4.sup.2- and Cl.sup.- ions can provide increased energy density and improved stability and solubility of one or more of the ionic species in the catholyte and/or anolyte. According to one example, a vanadium-based redox flow battery system is characterized by an anolyte having V.sup.2+ and V.sup.3+ in a supporting solution and a catholyte having V.sup.4+ and V.sup.5+ in a supporting solution. The supporting solution can contain Cl.sup.- ions or a mixture of SO.sub.4.sup.2- and Cl.sup.- ions.
Redox flow battery systems having a supporting solution that contains Cl.sup.- ions can exhibit improved performance and characteristics. Furthermore, a supporting solution having mixed SO.sub.4.sup.2- and Cl.sup.- ions can provide increased energy density and improved stability and solubility of one or more of the ionic species in the catholyte and/or anolyte. According to one example, a vanadium-based redox flow battery system is characterized by an anolyte having V.sup.2+ and V.sup.3+ in a supporting solution and a catholyte having V.sup.4+ and V.sup.5+ in a supporting solution. The supporting solution can contain Cl.sup.- ions or a mixture of SO.sub.4.sup.2- and Cl.sup.- ions.
High performance water heaters are typically more time consuming and costly to install in retrofit applications, making high performance water heaters difficult to justify economically. However, recent advancements in high performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands. The water heaters tested for this project were designed to improve the cost-effectiveness and increase market penetration of high efficiency water heaters in the residential retrofit market. The retrofit high efficiency water heaters achieved their goal of reducing costs, maintaining savings potential and installed efficiency of other high efficiency water heaters, and meeting the necessary capacity in order to improve cost-effectiveness. However, the improvements were not sufficient to achieve simple paybacks of less than ten years for the incremental cost compared to a minimum efficiency heater. Significant changes would be necessary to reduce the simple payback to six years or less. Annual energy savings in the range of $200 would also reduce paybacks to less than six years. These energy savings would require either significantly higher fuel costs (greater than $1.50 per therm) or very high usage (around 120 gallons per day). For current incremental costs, the water heater efficiency would need to be similar to that of a heat pump water heater to deliver a six year payback.
High-performance water heaters are typically more time consuming and costly to install in retrofit applications, making high-performance water heaters difficult to justify economically. However, recent advancements in high-performance water heaters have targeted the retrofit market, simplifying installations and reducing costs. Four high-efficiency natural gas water heaters designed specifically for retrofit applications were installed in single-family homes along with detailed monitoring systems to characterize their savings potential, their installed efficiencies, and their ability to meet household demands.
The interaction between plants and their associated microbiomes is difficult to visualize in situ and requires a transparent culturing platform that can capture the length and time scales in which these dynamic relationships occur. We have used lab-on-a-chip technology to create such a platform and have successfully co-cultured Arabidopsis thaliana with beneficial bacteria. Here we quantify the changes in root morphology over time and discuss the potential of the system to characterize the kinetics and spatial distribution of root colonization.
Redox flow battery systems having a supporting solution that contains Cl.sup.- ions can exhibit improved performance and characteristics. Furthermore, a supporting solution having mixed SO.sub.4.sup.2- and Cl.sup.- ions can provide increased energy density and improved stability and solubility of one or more of the ionic species in the catholyte and/or anolyte. According to one example, a vanadium-based redox flow battery system is characterized by an anolyte having V.sup.2+ and V.sup.3+ in a supporting solution and a catholyte having V.sup.4+ and V.sup.5+ in a supporting solution. The supporting solution can contain Cl.sup.- ions or a mixture of SO.sub.4.sup.2- and Cl.sup.- ions.
TOF-PET detector systems, and methods for imaging photon-emitting samples using the detector systems, are provided. The TOF-PET detector systems use large-area photodetectors with extremely high time-resolution and an approach to data collection and analysis that allows for the use of inexpensive low-density scintillator materials. The TOF-PET detector systems are characterized by their ability to identify, on a statistical basis, the transverse and depth location of the first of the series of energy deposition events that are generated when a gamma photon enters the low-density scintillator material.
In imaging applications, such as X-ray radiography, the experimental system setup and data capture process introduce system blur and distortion. In images taken with thick scintillators, a spatially varying system blur is observed, requiring a nonstandard approach to blur and distortion estimation and removal. We demonstrate an approach to estimation of local point spread functions using checkerboard radiographs collected at the Naval Research Laboratory and extend that into a map defining the kernel over the camera field of view.
Explore the source record for details and available documents.
Abstract not provided.