Search NASA⌕ Search

SEARCH · Search NASA

Results for “testing facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Development and preliminary validation of a mechanistic multiscale model for fuel-cladding chemical interaction in metallic nuclear fuels

Despite decades of fuel rod material and design improvements, fuel-cladding chemical interaction (FCCI) remains the single-most lifetime-limiting behavior for modern metallic fuel rods. Constraining fuel lifetime increases operating costs, limiting the economic viability of commercializing metallic nuclear fuel technology. A mechanistic multiscale model utilizing the finite element method-based MARMOT and BISON codes was developed to more confidently predict cladding-side FCCI and its impact on fuel performance. The new BISON model incorporates mesoscale models for the effects of fuel microstructure evolution on the transport of wastage-inducing lanthanides through the fuel and for the kinetics of cladding wastage layer growth. The mesoscale models, in turn, build on lanthanide transport property data obtained from the atomistic scale. Preliminary validation studies using wastage thickness and cladding profilometry data from four fuel rods irradiated in Experimental Breeder Reactor II experiment X447 and one fuel rod from Fast Flux Test Facility experiment IFR1 show that the new model predicts cladding wastage and its effects on cladding deformation as well as existing empirical FCCI correlations. The new model is expected to aid in the design of new metallic fuel concepts, including fuel additives, cladding liners, and sodium-free annular fuel geometries. In conclusion, future work will focus on broader validation and refinement of the model’s treatment of different fuel alloys and cladding materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Flow instabilities in helical-coil steam generators for small modular reactors: A review

Here, this study covers the research and discoveries in two-phase flow-boiling instabilities available in the literature—specifically for a helical-coil steam generator (HCSG), including experimental findings, theoretical research, computational models, and system code analyses—supporting research and development of representative small modular reactors (SMRs). Like other new and advanced reactor systems, water-cooled SMRs require experimental data from both integral and separate thermal-hydraulics test facilities for the verification and validation (V&V) of the computational models and computer codes in order to design and obtain regulatory approval. The complex dynamics of two-phase flow-boiling instabilities includes flow regimes physics phenomena, flow-channel geometries, heat-transfer behavior, and interactions among the solid–liquid-gas within the system boundary, all of which are pivotal for understanding the design and operational challenges of SMRs. This study focuses on identifying the relevant knowledge gaps on boiling instabilities—specifically for a HCSG—and provides insights about future research direction optimizing the transport of thermal energy, mass-flow rates, and boundary conditions that ensure the adequate heat-transfer performance, operational stability, and safety associated with SMR systems.

20 FOSSIL-FUELED POWER PLANTS↗

Root cause analysis of a molten salt pump in FLUSTFA

The primary salt pump installed in the high-temperature FLUoride Salt Test Facility (FLUSTFA) was successfully operated for some time, but later ceased operation. To understand what occurred, a Root Cause Analysis (RCA) was performed. Steps taken to try to get the pump operational include adjusting the shaft position, increasing the heating power of the tape heaters on the pump volute, and manually rotating the pump shaft. While removing the insulation, corrosion was noted on the outside of the pump volute, and decolorization of the insulation and tape heaters was observed. Significant corrosion products were also observed in the pump itself and the piping connected to the pump. The nitrogen cover gas was maintained from before salt was introduced into the loop until the pump was dismounted and continues to be maintained even after the pump was removed. After considering probable scenarios, causes were assigned and corrective actions were developed to prevent those causes. Then, the RCA was presented to an advisory committee for review, the “Review Committee,” consisting of experts in large molten salt systems: Brandon Haugh, David Holcomb, Kevin Robb, and Vicente Rojas. As a result, the advisory committee provided comprehensive feedback, which have been incorporated into a revised RCA. Findings have then been summarized and reported in this publication.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

SMR safety through HTTF modeling and benchmark efforts for code validation for gas-cooled reactor applications

Accurate modeling and simulation tools for thermal-hydraulics calculations are a key element needed to design and license new advanced reactors including Small Modular Reactors (SMR) and Microreactors. Uncertainties in modeling and simulation can have significant safety and economic implications. The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled prismatic-block nuclear reactors. High-quality measurement data is available from the HTTF that is suitable for a thermal-hydraulics code validation benchmark for gas-cooled reactor simulations. Here, this paper summarizes individual HTTF modeling efforts to date for tool validation at Idaho National Laboratory (INL), Argonne National Laboratory (ANL), Oregon State University (OSU) and Canadian Nuclear Laboratories (CNL) using system thermal-hydraulics codes, Computational Fluid Dynamics (CFD) codes and system-CFD code couplings. Also, the paper introduces the ongoing OECD Nuclear Energy Agency (NEA) High Temperature Gas Reactor Thermal-Hydraulics (HTGR T/H) benchmark that allows for better comparisons of results between different international modeling teams. The benchmark provides well defined computational problems that include code-to-code comparisons and comparisons to measured data. These problems provide an avenue for quantifying accuracy and identifying sources of uncertainty in thermal-hydraulics calculations, including in measured thermophysical properties, as part of validation for gas-cooled reactor simulation tools.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Enhanced geometric capabilities for the transient analysis code T-ReX and its application to simulating TREAT experiments

Here, advances in computational architecture have prompted a resurgence in the simulation of reactor transients from first principles. Most codes are unable to simulate transient events with complex models, and require numerous approximations. The code T-ReX (Transient-Reactor eXperiment simulator), an extensive update to TDKENO, has been developed as a transient analysis tool with few geometric limitations and minimal theoretical approximations. T-ReX achieves this by employing the Improved Quasi-Static (IQS) method to solve the time dependent Boltzmann transport equation with explicit representation of delayed neutrons. The primary change in T-ReX relative to TDKENO is the incorporation of a modified version of the Monte Carlo code KENO-VI to calculate the flux shape and model the geometry of a problem. Using KENO-VI to model systems allows exact representation of the geometry. The changes to T-ReX are verified by comparison of solutions to computational benchmark problems found with a previous version of TDKENO that made use of KENO V.a, and several other codes with time-dependent capabilities. In addition, a three-dimensional model of the Transient Reactor Test Facility (TREAT) core at the Idaho National Laboratory (INL) is constructed with KENO-VI, and used to validate T ReX. T-ReX produces results that agree with benchmark problems, and are in better agreement with TREAT experimental data than TDKENO.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Emulation of reactor irradiation damage using ion beams

The continued operation of existing light water nuclear reactors and the development of advanced nuclear reactor depend heavily on understanding how damage by radiation to levels degrades materials that serve as the structural components in reactor cores. The first high dose ion irradiation experiments on a ferritic-martensitic steel showing that ion irradiation closely emulates the full radiation damage microstructure created in-reactor are described. Ferritic-martensitic alloy HT9 (heat 84425) in the form of a hexagonal fuel bundle duct (ACO-3) accumulated 155 dpa at an average temperature of 443°C in the Fast Flux Test Facility (FFTF). Using invariance theory as a guide, irradiation of the same heat was conducted using self-ions (Fe++) at 5 MeV at a temperature of 460°C and to a dose of 188 displacements per atom. The void swelling was nearly identical between the two irradiation and the size and density of precipitates and loops following ion irradiation are within a factor of two of those for neutron irradiation. The level of agreement across all of the principal microstructure changes between ion and reactor irradiation establishes the capability of tailoring ion irradiation to emulate the reactor-irradiated microstructure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.

Gardon gauge↗

Volumetric efficiency and pressure pulsations of a triplex reciprocating supercritical CO 2 pump

A reciprocating triplex pump has been integrated into a closed-loop supercritical carbon dioxide test facility. The pump is designed to compress liquid or supercritical carbon dioxide and has a maximum volumetric flow rate of 51 L/min. A sweep across the pump’s speed range of 100–1000 rev/min was performed with inlet conditions between 60 and 160 bar. The volumetric efficiency was found to increase as pump speed increased from 10 to 40 % before it plateaued at higher pump speeds. The mechanical efficiency increased linearly with pump speed and was not affected by system pressure. Pressure pulsations caused by the plungers and valves were also measured at each speed. Additionally, a 35-liter buffer volume, connected near the pump’s discharge was isolated at each speed to determine its effectiveness as a pulsation dampener. Overall the reciprocating pump was shown to perform exceptionally with liquid or supercritical inlet conditions applicable to many supercritical fluid applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accelerating Innovation that Enhances Resource Recovery in the Wastewater Sector: Advancing a National Testbed Network

This article examines significant challenges and opportunities to spur innovation and accelerate adoption of reliable technologies that enhance integrated resource recovery in the wastewater sector through the creation of a national testbed network. The network is a virtual entity that connects appropriate physical testing facilities, and other components needed for a testbed network, with researchers, investors, technology providers, utilities, regulators, and other stakeholders to accelerate the adoption of innovative technologies and processes that are needed for the water resource recovery facility of the future. Here we summarize and extract key issues and developments, to provide a strategy for the wastewater sector to accelerate a path forward that leads to new sustainable water infrastructures.

54 ENVIRONMENTAL SCIENCES↗

Modeling energy in an Integrated Pollutant Removal (IPR) system with CO{sub 2} capture integrated with oxy-fuel combustion

Oxy-coal combustion is one of the technical solutions for mitigating CO{sub 2} in thermal power plants. Many processes have been evolved in past the decade to capture CO{sub 2} from process industries. Researchers at the National Energy Technology Laboratory (NETL) have patented a process, integrated pollutant removal (IPR), that uses off the shelf technology to produce a sequestration-ready CO{sub 2} stream from an oxy-combustion power plant. The IPR process as it is realized at the Jupiter Oxygen Burner Test Facility is a spray tower (direct-contact heat exchanger) followed by four stages of compression with intercooling. To study the energy flows of the oxy-combustion process, a 15 MW{sub t}h oxy-combustion pulverized-coal-fired plant integrated with the IPR system was simulated and analyzed using ASPEN Plus and ASPEN energy analyzer. This paper discusses flue-gas recycle, energy flow, recovery, and optimization of IPR systems. ASPEN models of heat- and mass-transfer processes in aflue-gas-condensing heat-exchanger system were developed to predict the heat transferred from flue gas to cooling water. The flue-gas exit temperature, cooling water outlet temperature, and energy flows of IPR streams were computed using ASPEN models. Pinch principles are deployed for targeting design and operation-guiding purposes and balancing the heat and mass transfer in the IPR system. The results are expected to support sophistication of the IPR system design, improving its application in a variety of settings. They open the door for valuable IPR efficiency improvements and generalization of methodology for simultaneous management of energy resources.

20 FOSSIL-FUELED POWER PLANTS↗

Experimental Testing Scale Considerations for the Investigation of Bare‐Soil Evaporation Dynamics in the Presence of Sustained Above‐Ground Airflow

Abstract At the fundamental process level, many of the concepts that form the foundation of our understanding of bare‐soil evaporation dynamics have advanced little since their initial formation. This investigation explores experimental scaling issues that should be considered during the study of bare‐soil evaporation dynamics under conditions of sustained above‐ground airflow. Results are presented from a series of large‐scale laboratory experiments conducted for various soil conditions (i.e., heterogeneity and surface roughness). Fundamental experimental research of this nature is not feasible in the field or small laboratory columns that are limited by system control and scale. All experimentation was therefore conducted in a test facility that couples a climate‐controlled, low‐speed wind tunnel with a 7.15‐m‐long soil tank—allowing for control over soil properties and initial and boundary conditions. Measured flow phenomena supported, and agreed well with, existing wind tunnel and field study literature. These data were in turn, used to explain observed evaporative water loss and soil moisture distribution spatiotemporal trends and patterns. Results demonstrated that relatively large length scales are required for the impacts of atmospheric feedbacks on the subsurface hydrodynamics to manifest themselves and become quantifiable. Airflow had the greatest impact in the case of a flat homogeneous soil; the strength of this feedback was significantly weaker in the presence of soil heterogeneities and surface undulations that were dominated by other transport phenomena. Comparison of these results with those of past studies furthermore cautions against the use of column scale data to make generalizations about bare‐soil evaporation dynamic upscaling.

Trautz, Andrew C.↗

Building fault detection data to aid diagnostic algorithm creation and performance testing

It is estimated that approximately 4-5% of national energy consumption can be saved through corrections to existing commercial building controls infrastructure and resulting improvements to efficiency. Correspondingly, automated fault detection and diagnostics (FDD) algorithms are designed to identify the presence of operational faults and their root causes. A diversity of techniques is used for FDD spanning physical models, black box, and rule-based approaches. A persistent challenge has been the lack of common datasets and test methods to benchmark their performance accuracy. This article presents a first of its kind public dataset with ground-truth data on the presence and absence of building faults. This dataset spans a range of seasons and operational conditions and encompasses multiple building system types. It contains information on fault severity, as well as data points reflective of the measurements in building control systems that FDD algorithms typically have access to. The data were created using simulation models as well as experimental test facilities, and will be expanded over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A labeled dataset for building HVAC systems operating in faulted and fault-free states

Abstract Open data is fueling innovation across many fields. In the domain of building science, datasets that can be used to inform the development of operational applications - for example new control algorithms and performance analysis methods - are extremely difficult to come by. This article summarizes the development and content of the largest known public dataset of building system operations in faulted and fault free states. It covers the most common HVAC systems and configurations in commercial buildings, across a range of climates, fault types, and fault severities. The time series points that are contained in the dataset include measurements that are commonly encountered in existing buildings as well as some that are less typical. Simulation tools, experimental test facilities, and in-situ field operation were used to generate the data. To inform more data-hungry algorithms, most of the simulated data cover a year of operation for each fault-severity combination. The data set is a significant expansion of that first published by the lead authors in 2020.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hard X-ray inverse Compton scattering at photon energy of 87.5 keV

Abstract Production of hard X-ray via inverse Compton scattering at photon energies below 100 keV range aimed at potential applications in medicine and material research is reported. Experiments have been performed at the Brookhaven National Laboratory, Accelerator Test Facility, employing the counter collision of a 70 MeV, 0.3 nC electron beam with a near infra-red Nd: YAG laser (1064 nm wavelength) pulse containing ~ 100 mJ in a single shot basis. The radiation distribution of the scattered photon beam is assessed to be sufficiently quasi monochromatic to produce clear contrast from the Au K - edge at 80.7 keV.

43 PARTICLE ACCELERATORS↗

Mitigating oil spills in the water column

The scale and scope of uncontrolled oil spills can be devastating. Diverse marine environments and fragile ecologies are some of the most susceptible to the many ill effects, while the economic costs can be crippling. A notoriously difficult challenge with no known technological solution is the successful removal of oil dispersed in the water column. Here, we address this problem through cheap and reusable oil sorbents based on the chemical modification of polymer foams. Interfacial chemistry was optimized and subsequently tested in a simulated marine environment at the National Oil Spill Response Research & Renewable Energy Test Facility, Ohmsett. We find favorable performance for surface oil mitigation and, for the first time, demonstrate the advanced sorbent's efficiency and efficacy at pilot scale in extraction of crude oil and refined petroleum products dispersed in the water column. As a result, this is a potentially disruptive technology, opening a new field of environmental science focused on sub-surface pollutant sequestration.

54 ENVIRONMENTAL SCIENCES↗

Low pressure and high power rf sources for negative hydrogen ions for fusion applications (ITER neutral beam injection) (invited)

The international fusion experiment ITER requires for the plasma heating and current drive a neutral beam injection system based on negative hydrogen ion sources at 0.3 Pa. The ion source must deliver a current of 40 A D{sup -} for up to 1 h with an accelerated current density of 200 A/m{sup 2} and a ratio of coextracted electrons to ions below 1. The extraction area is 0.2 m{sup 2} from an aperture array with an envelope of 1.5x0.6 m{sup 2}. A high power rf-driven negative ion source has been successfully developed at the Max-Planck Institute for Plasma Physics (IPP) at three test facilities in parallel. Current densities of 330 and 230 A/m{sup 2} have been achieved for hydrogen and deuterium, respectively, at a pressure of 0.3 Pa and an electron/ion ratio below 1 for a small extraction area (0.007 m{sup 2}) and short pulses (<4 s). In the long pulse experiment, equipped with an extraction area of 0.02 m{sup 2}, the pulse length has been extended to 3600 s. A large rf source, with the width and half the height of the ITER source but without extraction system, is intended to demonstrate the size scaling and plasma homogeneity of rf ion sources. The source operates routinely now. First results on plasma homogeneity obtained from optical emission spectroscopy and Langmuir probes are very promising. Based on the success of the IPP development program, the high power rf-driven negative ion source has been chosen recently for the ITER beam systems in the ITER design review process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bulk and Surface Charge Collection: CDMS Detector Performance and Design Implications

The Cryogenic Dark Matter Search (CDMS) searches for Weakly Interacting Massive Particles (WIMPs) with cryogenic germanium particle detectors. These detectors discriminate between nuclear-recoil candidate and electron-recoil background events by collecting both phonon and ionization energy from interactions in the crystal. Incomplete ionization collection results in the largest background in the CDMS detectors as this causes electron-recoil background interactions to appear as false candidate events. Two primary causes of incomplete ionization collection are surface and bulk charge trapping. Recent work has been focused on reducing surface trapping through the modification of fabrication methods for future detectors. Analyzing data taken with test devices shows that hydrogen passivation of the amorphous silicon blocking layer does not reduce the effects of surface trapping. Other data shows that the iron-ion implantation used to lower the critical temperature of the tungsten transition-edge sensors increases surface trapping, causing a degradation of the ionization collection. Using selective implantation on future detectors may improve ionization collection for events near the phonon side detector surface. Bulk trapping is minimized by neutralizing ionized lattice impurities. Detector investigations at testing facilities and at the experimental site in Soudan, MN have provided methods to optimize the neutralization process and monitor running conditions to maintain maximal ionization collection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗