Search NASA⌕ Search

SEARCH · Search NASA

Results for “timing synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

A unified analysis of pseudonoise synchronization by envelope correlation

A relationship between coarse acquisition (coarse alignment of two pseudonoise codes to within approximately one code symbol) and fine acquisition (tracking) in a pseudonoise modulated spread spectrum communication system is studied. A convenient technique for determining mean acquisition time and hold-in time (mean time to lose lock) after acquisition, using a delay lock loop, is elaborated. An analysis procedure for handling the transition from search to lock is developed and applied to a problem containing representative Space Shuttle data (signal parameters and synchronizer parameters).

Hopkins, P. M.↗

Small Cell Carcinoma of the Urinary Bladder: A Retrospective, Multicenter Rare Cancer Network Study of 107 Patients

Purpose: Small cell carcinomas of the bladder (SCCB) account for fewer than 1% of all urinary bladder tumors. There is no consensus regarding the optimal treatment for SCCB. Methods and Materials: Fifteen academic Rare Cancer Network medical centers contributed SCCB cases. The eligibility criteria were as follows: pure or mixed SCC; local, locoregional, and metastatic stages; and age ≥18 years. The overall survival (OS) and disease-free survival (DFS) were calculated from the date of diagnosis according to the Kaplan-Meier method. The log-rank and Wilcoxon tests were used to analyze survival as functions of clinical and therapeutic factors. Results: The study included 107 patients (mean [±standard deviation, SD] age, 69.6 [±10.6] years; mean follow-up time, 4.4 years) with primary bladder SCC, with 66% of these patients having pure SCC. Seventy-two percent and 12% of the patients presented with T2-4N0M0 and T2-4N1-3M0 stages, respectively, and 16% presented with synchronous metastases. The most frequent curative treatments were radical surgery and chemotherapy, sequential chemotherapy and radiation therapy, and radical surgery alone. The median (interquartile range, IQR) OS and DFS times were 12.9 months (IQR, 7-32 months) and 9 months (IQR, 5-23 months), respectively. The metastatic, T2-4N0M0, and T2-4N1-3M0 groups differed significantly (P=.001) in terms of median OS and DFS. In a multivariate analysis, impaired creatinine clearance (OS and DFS), clinical stage (OS and DFS), a Karnofsky performance status <80 (OS), and pure SCC histology (OS) were independent and significant adverse prognostic factors. In the patients with nonmetastatic disease, the type of treatment (ie radical surgery with or without adjuvant chemotherapy vs conservative treatment) did not significantly influence OS or DFS (P=.7). Conclusions: The prognosis for SCCB remains poor. The finding that radical cystectomy did not influence DFS or OS in the patients with nonmetastatic disease suggests that conservative treatment is appropriate in this situation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

LASSO observations at McDonald and OCA/CERGA: A preliminary analysis

The Laser Synchronization from Synchronous Orbit (LASSO) observations between USA and Europe were made possible with the move of Meteosat 3/P2 toward 50 deg W. Two Lunar Laser Ranging stations participated into the observations: the MLRS at McDonald Observatory (Texas, USA) and OCA/CERGA (Grasse, France). Common sessions were performed since 30 Apr. 1992, and will be continued up to the next Meteosat 3/P2 move further West (planned for January 1993). The preliminary analysis made with the data already collected by the end of Nov. 1992 shows that the precision which can be obtained from LASSO is better than 100 ps, the accuracy depending on how well the stations maintain their time metrology, as well as on the quality of the calibration (still to be made.) For extracting such a precision from the data, the processing has been drastically changed compared to the initial LASSO data analysis. It takes into account all the measurements made, timings on board, and echoes at each station. This complete use of the data increased dramatically the confidence into the synchronization results.

Veillet, CH.↗

Laser Communications Relay Demonstration Optimetrics Experiment

Within this paper, we report on an Optimetrics experiment conducted on the National Aeronautics and Space Administration (NASA) Laser Communication Relay Demonstration (LCRD). The high precision two-way ranging is conducted on the optical communications link between the LCRD space terminal in a geosynchronous orbit and the Optical Ground Station 1 (OGS1) at Table Mountain, California, and is referred to as optimetrics ranging. The receiver to transmitter clock loopback is implemented in the LCRD space modem. A digital dual mixer time difference phase meter (DDMTD) is implemented in the OGS1 ground modem. The round-trip time is measured with the DDMTD by counting the frame and data clock ticks between transmitter and receiver frame synchronization markers for coarse range, and the relative phase of the transmit and receive clock for high precision range. This approach provides coverage for all potential ranges with no ranging ambiguity. The flight modem FPGA code was modified for frame and data clock loopback and the OGS1 FPGA code was modified for the DDMTD phase meter implementation. The experiment team conducted a 36-hour continuous ranging measurement. Preliminary two-way optimetrics ranging data show a noise floor of 3cm (rms). Based on our theoretical noise analysis and ground tests with spare flight modems, we expected one order of magnitude improvement on ranging precision. We are conducting detailed post data processing to identify the differences to further reduce the noise level and formulating an improved implementation approach for future missions. For reference and comparison, traditional Radio Frequency (RF) ranging between LCRD and OGS1 was conducted at the same time and indicates a ranging noise floor of 30cm(rms). Other telemetry and relevant environmental parameters such as weather and atmosphere temperature were also collected for offline data processing. The high precision ranging and range rate measurements from the laser communications data link clock and clock phase are performed simultaneously with continuous optical communication. No extra hardware added to existing system. This high precision optimetrics measurement implementation provides alternative ranging and range rate measurements for orbit determination (OD) and flight dynamics calculations with higher precision. We see significant improvement on OD for navigation upon implementation in future optical communication systems.

Rafael Garcia↗

DCS - A high flux beamline for time resolved dynamic compression science – Design highlights

The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures. Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm{sup 2}. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm{sup 2}. A new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A system for EPID-based real-time treatment delivery verification during dynamic IMRT treatment

Purpose: To design and develop a real-time electronic portal imaging device (EPID)-based delivery verification system for dynamic intensity modulated radiation therapy (IMRT) which enables detection of gross treatment delivery errors before delivery of substantial radiation to the patient.Methods: The system utilizes a comprehensive physics-based model to generate a series of predicted transit EPID image frames as a reference dataset and compares these to measured EPID frames acquired during treatment. The two datasets are using MLC aperture comparison and cumulative signal checking techniques. The system operation in real-time was simulated offline using previously acquired images for 19 IMRT patient deliveries with both frame-by-frame comparison and cumulative frame comparison. Simulated error case studies were used to demonstrate the system sensitivity and performance.Results: The accuracy of the synchronization method was shown to agree within two control points which corresponds to approximately ∼1% of the total MU to be delivered for dynamic IMRT. The system achieved mean real-time gamma results for frame-by-frame analysis of 86.6% and 89.0% for 3%, 3 mm and 4%, 4 mm criteria, respectively, and 97.9% and 98.6% for cumulative gamma analysis. The system can detect a 10% MU error using 3%, 3 mm criteria within approximately 10 s. The EPID-based real-time delivery verification system successfully detected simulated gross errors introduced into patient plan deliveries in near real-time (within 0.1 s).Conclusions: A real-time radiation delivery verification system for dynamic IMRT has been demonstrated that is designed to prevent major mistreatments in modern radiation therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Compiled MPI: Cost-Effective Exascale Applications Development

The complexity of petascale and exascale machines makes it increasingly difficult to develop applications that can take advantage of them. Future systems are expected to feature billion-way parallelism, complex heterogeneous compute nodes and poor availability of memory (Peter Kogge, 2008). This new challenge for application development is motivating a significant amount of research and development on new programming models and runtime systems designed to simplify large-scale application development. Unfortunately, DoE has significant multi-decadal investment in a large family of mission-critical scientific applications. Scaling these applications to exascale machines will require a significant investment that will dwarf the costs of hardware procurement. A key reason for the difficulty in transitioning today's applications to exascale hardware is their reliance on explicit programming techniques, such as the Message Passing Interface (MPI) programming model to enable parallelism. MPI provides a portable and high performance message-passing system that enables scalable performance on a wide variety of platforms. However, it also forces developers to lock the details of parallelization together with application logic, making it very difficult to adapt the application to significant changes in the underlying system. Further, MPI's explicit interface makes it difficult to separate the application's synchronization and communication structure, reducing the amount of support that can be provided by compiler and run-time tools. This is in contrast to the recent research on more implicit parallel programming models such as Chapel, OpenMP and OpenCL, which promise to provide significantly more flexibility at the cost of reimplementing significant portions of the application. We are developing CoMPI, a novel compiler-driven approach to enable existing MPI applications to scale to exascale systems with minimal modifications that can be made incrementally over the application's lifetime. It includes: (1) New set of source code annotations, inserted either manually or automatically, that will clarify the application's use of MPI to the compiler infrastructure, enabling greater accuracy where needed; (2) A compiler transformation framework that leverages these annotations to transform the original MPI source code to improve its performance and scalability; (3) Novel MPI runtime implementation techniques that will provide a rich set of functionality extensions to be used by applications that have been transformed by our compiler; and (4) A novel compiler analysis that leverages simple user annotations to automatically extract the application's communication structure and synthesize most complex code annotations.

97 MATHEMATICS AND COMPUTING↗

Power grid frequency prediction using spatiotemporal modeling

Understanding power system dynamics is essential for interarea oscillation analysis and the detection of grid instabilities. The FNET/GridEye is a GPS-synchronized wide-area frequency measurement network that provides an accurate picture of the normal real-time operational condition of the power system-dynamics, giving rise to new and intricate spatiotemporal patterns of power loads. We propose to model FNET/GridEye grid frequency data from the U.S. Eastern Interconnection with a spatiotemporal statistical model. We predict the frequency data at locations without observations, a critical need during disruption events where measurement data are inaccessible. Spatial information is accounted for either as neighboring measurements in the form of covariates or with a spatiotemporal correlation model captured by a latent Gaussian field. Finally, the proposed method is useful in estimating power system dynamic response from limited phasor measurements and holds promise for predicting instability that may lead to undesirable effects such as cascading outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ultrafast electrochemical preparation of graphene/CoS nanosheet counter electrodes for efficient dye-sensitized solar cells

Utilizing inexpensive, high-efficiency counter electrodes (CEs) to replace the traditional platinum counterparts in dye-sensitized solar cells (DSSCs) is worthwhile. In this paper, we detail how we synchronously prepared composite CEs of CoS nanosheet arrays and reduced graphene oxide (rGO) layers for the first time via a low temperature, ultrafast one-step electrochemical strategy. With this approach, the whole fabrication process of the composite CEs was only a small percentage of the average time (~15 hours) using other methods. The DSSC assembled with the rGO–CoS composite CE achieved an enhanced power conversion efficiency (PCE) of 8.34%, which is dramatically higher than 6.27% of pure CoS CE-based DSSC and even exceeds 7.50% of Pt CE-based DSSC. The outstanding PCE breakthrough is undoubtedly attributed to the enhancement in electrocatalytic ability of the rGO–CoS composite CE due to the incorporation of highly conducting rGO layers and the GO layers-induced growth of CoS nanosheet arrays with higher density and larger surface area. Therefore, lower charge-transfer resistance and higher exchange current density can be achieved as corroborated by the electrochemical impedance spectra (EIS) and Tafel polarization curves (TPCs). As a result, further experiments also proved that the electrochemical strategy exhibited its universality of fabricating other graphene-enhanced chalcogenide functional composite films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A customizable data management framework for high-repetition-rate high-energy-density science

The high-energy-density (HED) physics community is moving toward a new paradigm of high-repetition-rate (HRR) operation. To fully leverage the scientific power of HRR HED facilities, all of the components of each subsystem (laser, targetry, and performance diagnostics) must be connected and synchronized in a reliable and robust manner while the data acquired are tagged and archived in real time. To this end, GA has begun developing a generalized NoSQL-database framework, the MongoDB repository for information and archiving. An organizational strategy has been developed that shifts HED data organization from a shot-based to a diagnostic-based approach in order to increase archival and retrieval efficiency that lends itself to optimization applications. This work is a first step in pushing HRR HED science toward data management solutions that emphasize machine actionability and aim to stimulate community engagement to define data standards in HED science.

Instruments & Instrumentation↗

Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study

Purpose: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CT can significantly reduce lung imaging artifacts. Methods: Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) “conventional” 4D CT that uses a constant imaging and couch-shift frequency, (ii) “beam paused” 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) “respiratory-gated” 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm{sup 3} spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Results: Averaged across all simulations and phase bins, respiratory-gating reduced overall thoracic MSE by 46% compared to conventional 4D CT (p ∼ 10{sup −19}). Gating leads to small but significant (p < 0.02) reductions in lung volume errors (1.8%–1.4%), false positives (4.0%–2.6%), and false negatives (2.7%–1.3%). These percentage reductions correspond to gating reducing image artifacts by 24–90 cm{sup 3} of lung tissue. Similar to earlier studies, gating reduced patient image dose by up to 22%, but with scan time increased by up to 135%. Beam paused 4D CT did not significantly impact normal lung tissue image quality, but did yield similar dose reductions as for respiratory-gating, without the added cost in scanning time. Conclusions: For a typical 6 L lung, respiratory-gated 4D CT can reduce image artifacts affecting up to 90 cm{sup 3} of normal lung tissue compared to conventional acquisition. This image improvement could have important implications for dose calculations based on 4D CT. Where image quality is less critical, beam paused 4D CT is a simple strategy to reduce imaging dose without sacrificing acquisition time.

60 APPLIED LIFE SCIENCES↗

An all digital phase locked loop for FM demodulation.

A phase-locked loop designed with all-digital circuitry which avoids certain problems, and a digital voltage controlled oscillator algorithm are described. The system operates synchronously and performs all required digital calculations within one sampling period, thereby performing as a real-time special-purpose computer. The SNR ratio is computed for frequency offsets and sinusoidal modulation, and experimental results verify the theoretical calculations.

Greco, J.↗

International Ultraviolet Explorer (IUE) satellite mission analysis

The results are presented of the mission analysis performed by Computer Sciences Corporation (CSC) in support of the International Ultraviolet Explorer (IUE) satellite. The launch window is open for three separate periods (for a total time of 7 months) during the year extending from July 20, 1977, to July 20, 1978. The synchronous orbit shadow constraint limits the launch window to approximately 88 minutes per day. Apogee boost motor fuel was computed to be 455 pounds (206 kilograms) and on-station weight was 931 pounds (422 kilograms). The target orbit is elliptical synchronous, with eccentricity 0.272 and 24 hour period.

Cook, R. A.↗

Improved frame synchronization schemes for INMARSAT-B/M SCPC and TDM channels

This paper proposes faster, more robust, frame synchronization schemes for various Inmarsat-B and Inmarsat-M communication and signalling channels. Equations are developed which permit frame synchronization strategies of the type specified by Inmarsat to be evaluated in terms of average true lock time, average false maintenance time, and average search time. Evaluation of the currently specified framing schemes shows that a significant performance improvement is obtained by optimizing the threshold parameters of the scheme. The optimization seeks a compromise between the conflicting requirements of maximizing true lock time and minimizing search time.

Pan, Si-Ming↗

Numerical Simulation of Rolling-Airframes Using a Multi-Level Cartesian Method

A supersonic rolling missile with two synchronous canard control surfaces is analyzed using an automated, inviscid, Cartesian method. Sequential-static and time-dependent dynamic simulations of the complete motion are computed for canard dither schedules for level flight, pitch, and yaw maneuver. The dynamic simulations are compared directly against both high-resolution viscous simulations and relevant experimental data, and are also utilized to compute dynamic stability derivatives. The results show that both the body roll rate and canard dither motion influence the roll-averaged forces and moments on the body. At the relatively, low roll rates analyzed in the current work these dynamic effects are modest, however the dynamic computations are effective in predicting the dynamic stability derivatives which can be significant for highly-maneuverable missiles.

Murman, Scott M.↗

Reprogrammable field programmable gate array with integrated system for mitigating effects of single event upsets

An integrated system mitigates the effects of a single event upset (SEU) on a reprogrammable field programmable gate array (RFPGA). The system includes (i) a RFPGA having an internal configuration memory, and (ii) a memory for storing a configuration associated with the RFPGA. Logic circuitry programmed into the RFPGA and coupled to the memory reloads a portion of the configuration from the memory into the RFPGA's internal configuration memory at predetermined times. Additional SEU mitigation can be provided by logic circuitry on the RFPGA that monitors and maintains synchronized operation of the RFPGA's digital clock managers.

Ng, Tak-kwong↗

Aquarius Radiometer RFI Detection, Mitigation, and Impact Assessment

The Aquarius/SAC-D satellite was launched on 10 June 2011 into a sun-synchronous polar orbit and the Aquarius microwave radiometers [1] became operational on 25 August 2011. Since that time, it has been measuring brightness temperatures at 1.4 GHz with vertical, horizontal and 3rd Stokes polarizations . Beginning well before the launch, there has been the concern that Radio Frequency Interference (RFI) could have an appreciable presence. This concern was initiated by, among other things, its prevalence in both early [2] and more recent [3,4] aircraft field experiments using 1.4 GHz radiometers, as well as by the strong RFI environment encountered during the recent ESA SMOS mission, also at 1.4 GHz [5]. As a result, a number of methods for RFI detection and mitigation have been developed and tested. One in particular, "glitch detection" and "pulse blanking" mitigation has been adapted for use by Aquarius [6, 7]. The early on-orbit performance of the Aquarius RFI detection and mitigation algorithm is presented here, together with an assessment of the global RFI environment at 1.4 GHz which can be derived from the Aquarius results.

Ruf, Christopher↗