Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analytical Method Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Supercritical cascade design

The use of the method of complex extension to achieve better aerodynamic designs for supercritical cascades applicable to transonic turbomachinery is discussed. The method permits the computation of analytical solutions to elliptic, hyperbolic or mixed second-order partial equations in two dimensions. Boundary value problems formulated to develop an airfoil shape having a prescribed speed distribution for subsonic flow and a nearby speed distribution in the transonic case are also considered. Computing times necessary to run the blade design program are described as acceptably short.

Korn, D. G.↗

Inlet design technology development - Supersonic cruise research

An inlet technology development program for future supersonic cruise aircraft is in progress. Areas being emphasized are inlet aerodynamic and control system design requirements for efficient and reliable operation. Off-design conditions, such as angle of incidence, starting, and noise abatement are major considerations. Flow analysis procedures are being developed to predict the internal inviscid and viscous flows in axisymmtric supersonic inlets for these operating conditions. Also under development are control systems that will have significant interfaces with the engine control system, the flight control system, and the airframe avionics system. The analytical methods are being supported and validated with representative experiments.

Syberg, J.↗

Viscoelastic behavior and life-time predictions

Fiber reinforced plastics were considered for many structural applications in automotive, aerospace and other industries. A major concern was and remains the failure modes associated with the polymer matrix which serves to bind the fibers together and transfer the load through connections, from fiber to fiber and ply to ply. An accelerated characterization procedure for prediction of delayed failures was developed. This method utilizes time-temperature-stress-moisture superposition principles in conjunction with laminated plate theory. Because failures are inherently nonlinear, the testing and analytic modeling for both moduli and strength is based upon nonlinear viscoelastic concepts.

Dillard, D. A.↗

Sensing strategies for toxic vapor detection

This work was motivated by the recommendations of the American Conference of Governmental Industrial Hygienists (ACGIH) that threshold limits for hydrazine, H2N-NH2 in air be lowered from 100 to 10 parts-per-billion (ppb) concentration levels. Hydrazine is one of the high-energy propellants used in large volumes in Space Shuttle, Titan, payloads, and other aerospace operations. Since analytical methods presently available for hydrazine detection and/or determination do not satisfy such low levels of detection, the ultimate goal of this research is the development and characterization of a portable and compact chemical sensor ideally capable to detect (in real time) 1 ppb of hydrazine, continuously and reversibly. The laboratory prototype developed as part of this project is comprised of: (1) a reactor part in which H2N-NH2 reacts, generating chemiluminescence emission, with tris(2,2'-bipyridine)ruthenium(III), which is immobilized on an ion-exchange polymeric materials of a perfluorinated hydrocarbon containing sulfonate groups as exchange centers (Nafion); (2) an electrochemical three-electrode cell posed at a potential at which the immobilized ruthenium complex could be reoxidized to the 3-oxidation state (as to provide reversible and continuous detection); and (3) a low power consumption photomultiplier tube to collect and quantitatively integrate the emitted photons with the help of auxiliary electronics and readout device.

Mottola, Horacio A.↗

Photogrammetry Methodology Development for Gossamer Spacecraft Structures

Photogrammetry--the science of calculating 3D object coordinates from images--is a flexible and robust approach for measuring the static and dynamic characteristics of future ultra-lightweight and inflatable space structures (a.k.a., Gossamer structures), such as large membrane reflectors, solar sails, and thin-film solar arrays. Shape and dynamic measurements are required to validate new structural modeling techniques and corresponding analytical models for these unconventional systems. This paper summarizes experiences at NASA Langley Research Center over the past three years to develop or adapt photogrammetry methods for the specific problem of measuring Gossamer space structures. Turnkey industrial photogrammetry systems were not considered a cost-effective choice for this basic research effort because of their high purchase and maintenance costs. Instead, this research uses mainly off-the-shelf digital-camera and software technologies that are affordable to most organizations and provide acceptable accuracy.

Pappa, Richard S.↗

Photogrammetry Methodology Development for Gossamer Spacecraft Structures

Photogrammetry--the science of calculating 3D object coordinates from images-is a flexible and robust approach for measuring the static and dynamic characteristics of future ultralightweight and inflatable space structures (a.k.a., Gossamer structures), such as large membrane reflectors, solar sails, and thin-film solar arrays. Shape and dynamic measurements are required to validate new structural modeling techniques and corresponding analytical models for these unconventional systems. This paper summarizes experiences at NASA Langley Research Center over the past three years to develop or adapt photogrammetry methods for the specific problem of measuring Gossamer space structures. Turnkey industrial photogrammetry systems were not considered a cost-effective choice for this basic research effort because of their high purchase and maintenance costs. Instead, this research uses mainly off-the-shelf digital-camera and software technologies that are affordable to most organizations and provide acceptable accuracy.

Pappa, Richard S.↗

Hydrocarbon Cold-Flow Simulation of LOX/LH2 Rocket Aerodynamics

In FY19, this project developed a test method which employed heated ethane in the physical simulation of rocket plume aerodynamics. Based on this work, EUS partnered with significant leveraged funding. A portable, self-contained test bed was also fabricated to support validation of the new method. In FY20, this project focused on the formal validation of ethane’s performance as an aerodynamic simulant as well as the development of the analytical and hardware infrastructure required to carry out that task. The test bed was activated, a series of heated-ethane tests on one or more rocket/diffuser configurations were conducted, and characterizations of the performance of the ethane simulation compared to hot-fire were performed. A series of 127 tests were conducted on 13 aerodynamic configurations to evaluate ethane’s performance as a simulant. It was found that the new methodology can reproduce rocket plume flow fields with +/- 0.5% pressure error at ~3% physical scale. The result is a cost-per-test reduction of ~99% compared to the hot-fire subscale testing typically used to obtain equivalent data. Some initial efforts have taken place, and future efforts are being planned with LaRC supersonic retro propulsion and MSFC SLS aerodynamics teams, which are interested in using the ethane system to wind-tunnel test human-rated Mars lander retrorockets and SLS Booster. Details of the prototypical experiments were published as NASA TM 2020-5009122,and have been presented in JANNAF Virtual Conference paper, "New Developments in Retro propulsion Testing for Mars Entry, Descent and Landing".

Daniel Jones↗

Development of one-dimensional computational fluid dynamics code 'GFLOW' for groundwater flow and contaminant transport analysis

Prediction of groundwater movement and contaminant transport in soil is an important problem in many branches of science and engineering. This includes groundwater hydrology, environmental engineering, soil science, agricultural engineering and also nuclear engineering. Specifically, in nuclear engineering it is applicable in the design of spent fuel storage pools and waste management sites in the nuclear power plants. Ground water modeling involves the simulation of flow and contaminant transport by groundwater flow. In the context of contaminated soil and groundwater system, numerical simulations are typically used to demonstrate compliance with regulatory standard. A one-dimensional Computational Fluid Dynamics code GFLOW had been developed based on the Finite Difference Method for simulating groundwater flow and contaminant transport through saturated and unsaturated soil. The code is validated with the analytical model and the benchmarking cases available in the literature. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimal cooperative time-fixed impulsive rendezvous

A method has been developed for determining optimal, i.e., minimum fuel, trajectories for the fixed-time cooperative rendezvous of two spacecraft. The method presently assumes that the vehicles perform a total of three impulsive maneuvers with each vehicle being active, that is, making at least one maneuver. The cost of a feasible 'reference' trajectory is improved by an optimizer which uses an analytical gradient developed using primer vector theory and a new solution for the optimal terminal (rendezvous) maneuver. Results are presented for a large number of cases in which the initial orbits of both vehicles are circular but in which the initial positions of the vehicles and the allotted time for rendezvous are varied. In general, the cost of the cooperative rendezvous is less than that of rendezvous with one vehicle passive. Further improvement in cost may be obtained in the future when additional, i.e., midcourse, impulses are allowed and inserted as indicated for some cases by the primer vector histories which are generated by the program.

Mirfakhraie, Koorosh↗

Stellar Wakes from Dark Matter Subhalos

Here we propose a novel method utilizing stellar kinematic data to detect low-mass substructure in the Milky Way’s dark matter halo. By probing characteristic wakes that a passing dark matter subhalo leaves in the phase-space distribution of ambient halo stars, we estimate sensitivities down to subhalo masses of ∼10 7 M ⊙ or below. The detection of such subhalos would have implications for dark matter and cosmological models that predict modifications to the halo-mass function at low halo masses. We develop an analytic formalism for describing the perturbed stellar phase-space distributions, and we demonstrate through idealized simulations the ability to detect subhalos using the phase-space model and a likelihood framework. Our method complements existing methods for low-mass subhalo searches, such as searches for gaps in stellar streams, in that we can localize the positions and velocities of the subhalos today.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plasmonic Based Sensing Using an Array of Au-Metal Oxide Thin Films

An optical plasmonic-based sensing array has been developed and tested for the selective and sensitive detection of H2, CO, and NO2 at a temperature of 500°C in an oxygen-containing background. The three element sensing array used Au nanoparticles embedded in separate thin films of yttria stabilized zirconia (YSZ), CeO2, and TiO2. A peak in the absorbance spectrum due to a localized surface plasmon resonance (LSPR) on the Au nanoparticles was monitored for each film during gas exposures and showed a blue shift in the peak positions for the reducing gases, H2 and CO, and a red shift for the oxidizing gas NO2. A more in-depth look at the sensing response was performed using the multivariate methods of principal component analysis (PCA) analysis and linear discriminant analysis (LDA) on data from across the entire absorbance spectrum range. Qualitative results from both methods showed good separation between the three analytes for both the full array and the Au-TiO2 sample. Quantification of LDA cluster separation using the Mahalanobis distance showed better cluster separation for the array, but there were some instances with the lowest concentrations where the single Au-TiO2 film had better separation than the array. A second method to quantify cluster separation in LDA space was developed using multidimensional volume analysis of the individual cluster volume, overlapped cluster volume and empty volume between clusters. Compared to the individual sensing elements, the array showed less cluster overlap, smaller cluster volumes, and more space between clusters, all of which were expected for improved separability between the analytes.

Environmental Molecular Sciences Laboratory↗

Enhanced AFCI Sampling, Analysis, and Safeguards Technology Review

The focus of this study includes the investigation of sampling technologies used in industry and their potential application to nuclear fuel processing. The goal is to identify innovative sampling methods using state of the art techniques that could evolve into the next generation sampling and analysis system for metallic elements. Sampling and analysis of nuclear fuel recycling plant processes is required both to monitor the operations and ensure Safeguards and Security goals are met. In addition, environmental regulations lead to additional samples and analysis to meet licensing requirements. The volume of samples taken by conventional means, can restrain productivity while results samples are analyzed, require process holding tanks that are sized to meet analytical issues rather than process issues (and that create a larger facility footprint), or, in some cases, simply overwhelm analytical laboratory capabilities. These issues only grow when process flowsheets propose new separations systems and new byproduct material for transmutation purposes. Novel means of streamlining both sampling and analysis are being evaluated to increase the efficiency while meeting all requirements for information. This report addresses just a part of the effort to develop and study novel methods by focusing on the sampling and analysis of aqueous samples for metallic elements. It presents an overview of the sampling requirements, including frequency, sensitivity, accuracy, and programmatic drivers, to demonstrate the magnitude of the task. The sampling and analysis system needed for metallic element measurements is then discussed, and novel options being applied to other industrial analytical needs are presented. Inductively coupled mass spectrometry instruments are the most versatile for metallic element analyses and are thus chosen as the focus for the study. Candidate novel means of process sampling, as well as modifications that are necessary to couple such instruments to introduce these samples, are discussed. A suggested path forward based on an automated microchip capillary based sampling system interfaced to the analysis spectrometer is presented. The ability to obtain micro liter volume samples coupled with remote automated means of sample tracking and transport to the instrument would greatly improve analytical efficiency while reducing both personnel exposure and radioactive waste. Application of this sampling technique to new types of mass spectrometers for selective elemental isotopic analysis could also provide significant improvements in safeguards and security analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rapid determination of 210 Po in water samples

A new rapid method for the determination of 210 Po in water samples has been developed at the Savannah River National Laboratory (SRNL) that can be used for emergency response or routine water analyses. If a radiological dispersive device (RDD) event or a radiological attack associated with drinking water supplies occurs, there will be an urgent need for rapid analyses of water samples, including drinking water, ground water and other water effluents. Current analytical methods for the assay of 210 Po in water samples have typically involved spontaneous auto-deposition of 210 Po onto silver or other metal disks followed by counting by alpha spectrometry. The auto-deposition times range from 90 minutes to 24 hours or more, at times with yields that may be less than desirable. If sample interferences are present, decreased yields and degraded alpha spectrums can occur due to unpredictable thickening in the deposited layer. Separation methods have focused on the use of Sr Resin, often in combination with 210 Pb analysis. A new rapid method for 210 Po in water samples has been developed at the Savannah River National Laboratory (SRNL) that utilizes a rapid calcium phosphate co-precipitation method, separation using DGA Resin (N,N,N,N-tetraoctyldiglycolamide extractant-coated resin, Eichrom Technologies or Triskem-International), followed by rapid microprecipitation of 210 Po using bismuth phosphate for counting by alpha spectrometry. This new method can be performed quickly with excellent removal of interferences, high chemical yields and very good alpha peak resolution, eliminating any potential problems with the alpha source preparation for emergency or routine samples. A rapid sequential separation method to separate 210 Po and actinide isotopes was also developed. This new approach, rapid separation with DGA Resin plus microprecipitation for alpha source preparation, is a significant advance in radiochemistry for the rapid determination of 210 Po.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Reactor design and integration with product detection to accelerate screening of electrocatalysts for carbon dioxide reduction

Identifying new catalyst materials for complex reactions such as the electrochemical reduction of CO 2 poses substantial instrumentation challenges due to the need to integrate reactor control with electrochemical and analytical instrumentation. Performing accelerated screening to enable exploration of a broad span of catalyst materials poses additional challenges due to the long time scales associated with accumulation of reaction products and the detection of the reaction products with traditional separation-based analytical methods. The catalyst screening techniques that have been reported for combinatorial studies of (photo)electrocatalysts do not meet the needs of CO 2 reduction catalyst research, prompting our development of a new electrochemical cell design and its integration to gas and liquid chromatography instruments. To enable rapid chromatography measurements while maintaining sensitivity to minor products, the electrochemical cell features low electrolyte and head space volumes compared to the catalyst surface area. Additionally, the cell is operated as a batch reactor with electrolyte recirculation to rapidly concentrate reaction products, which serves the present needs for rapidly detecting minor products and has additional implications for enabling product separations in industrial CO 2 electrolysis systems. To maintain near-saturation of CO 2 in aqueous electrolytes, we employ electrolyte nebulization through a CO 2 -rich headspace, achieving similar gas-liquid equilibration as vigorous CO 2 bubbling but without gas flow. The instrument is demonstrated with a series of electrochemical experiments on an Au-Pd combinatorial library, revealing non-monotonic variations in product distribution with respect to catalyst composition. The highly integrated analytical electrochemistry system is engineered to enable automation for rapid catalyst screening as well as deployment for a broad range of electrochemical reactions where product distribution is critical to the assessment of catalyst performance.

47 OTHER INSTRUMENTATION↗

Application of vector-valued rational approximations to the matrix eigenvalue problem and connections with Krylov subspace methods

Let F(z) be a vectored-valued function F: C approaches C sup N, which is analytic at z=0 and meromorphic in a neighborhood of z=0, and let its Maclaurin series be given. We use vector-valued rational approximation procedures for F(z) that are based on its Maclaurin series in conjunction with power iterations to develop bona fide generalizations of the power method for an arbitrary N X N matrix that may be diagonalizable or not. These generalizations can be used to obtain simultaneously several of the largest distinct eigenvalues and the corresponding invariant subspaces, and present a detailed convergence theory for them. In addition, it is shown that the generalized power methods of this work are equivalent to some Krylov subspace methods, among them the methods of Arnoldi and Lanczos. Thus, the theory provides a set of completely new results and constructions for these Krylov subspace methods. This theory suggests at the same time a new mode of usage for these Krylov subspace methods that were observed to possess computational advantages over their common mode of usage.

Sidi, Avram↗

A Review of Biodegradable Plastics: Chemistry, Applications, Properties, and Future Research Needs

Environmental concerns over waste plastics’ effect on the environment are leading to the creation of biodegradable plastics. Biodegradable plastics may serve as a promising approach to manage the issue of environmental accumulation of plastic waste in the ocean and soil. Biodegradable plastics are the type of polymers that can be degraded by microorganisms into small molecules (e.g., H 2 O, CO 2 , and CH 4 ). However, there are misconceptions surrounding biodegradable plastics. For example, the term “biodegradable” on product labeling can be misconstrued by the public to imply that the product will degrade under any environmental conditions. Such misleading information leads to consumer encouragement of excessive consumption of certain goods and increased littering of products labeled as “biodegradable”. Here this review not only provides a comprehensive overview of the state-of-the-art biodegradable plastics but also clarifies the definitions and various terms associated with biodegradable plastics, including oxo-degradable plastics, enzyme-mediated plastics, and biodegradation agents. Analytical techniques and standard test methods to evaluate the biodegradability of polymeric materials in alignment with international standards are summarized. The review summarizes the properties and industrial applications of previously developed biodegradable plastics and then discusses how biomass-derived monomers can create new types of biodegradable polymers by utilizing their unique chemical properties from oxygen-containing functional groups. The terminology and methodologies covered in the paper provide a perspective on directions for the design of new biodegradable polymers that possess not only advanced performance for practical applications but also environmental benefits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New Developments in LC-MS and Other Hyphenated Techniques

Extensive challenges faced by analytical chemists in studying real world complex samples such as biological body fluids, tissue samples, environmental and geological samples have lead to the development of advanced analytical approaches. The vast array of contemporary technologies can be categorized into two major areas: sample separation and mass spectrometry analysis. Current state-of-the-art sample separation methods include gas chromatography, high performance liquid chromatography, ultra high pressure liquid chromatography, solid phase extraction, capillary electrophoresis, and gas phase separation techniques such as ion mobility spectrometry. The recent trend in sample separation is to combine (or hyphenate) multiple techniques that employ different separation mechanisms to maximize separation efficiency. The most widely used combinations include two-dimensional gas chromatography, strong cation exchange or weak cation exchange chromatography followed by reversed-phase liquid chromatography, two-dimensional reversed-phase liquid chromatography, liquid chromatography followed by ion mobility spectrometry and two-dimensional electrophoresis techniques. The introduction of atmospheric pressure ionization techniques such as electrospray ionization and matrix assisted laser desorption ionization and variations of the two have drastically increased the impact of mass spectrometry on bioanalytical applications. Mass spectrometry itself has tremendously improved over the years in terms of sensitivity, detection limits, dynamic range and sequencing capabilities. Currently, mass spectrometers can attain zeptomolole detection limits with five orders of magnitude dynamic range. In this chapter, we summarize recent developments in hyphenated techniques and their applications to complex sample analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗