Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Multi-Institutional Phase II Study of Proton Beam Therapy for Organ-Confined Prostate Cancer Focusing on the Incidence of Late Rectal Toxicities

Purpose: Proton beam therapy (PBT) is theoretically an excellent modality for external beam radiotherapy, providing an ideal dose distribution. However, it is not clear whether PBT for prostate cancer can clinically control toxicities. The purpose of the present study was to estimate prospectively the incidence of late rectal toxicities after PBT for organ-confined prostate cancer. Methods and Materials: The major eligibility criteria included clinical Stage T1-T2N0M0; initial prostate-specific antigen level of {<=}20 ng/mL and Gleason score {<=}7; no hormonal therapy or hormonal therapy within 12 months before registration; and written informed consent. The primary endpoint was the incidence of late Grade 2 or greater rectal toxicity at 2 years. Three institutions in Japan participated in the present study after institutional review board approval from each. PBT was delivered to a total dose of 74 GyE in 37 fractions. The patients were prospectively followed up to collect the data on toxicities using the National Cancer Institute-Common Toxicity Criteria, version 2.0. Results: Between 2004 and 2007, 151 patients were enrolled in the present study. Of the 151 patients, 75, 49, 9, 17, and 1 had Stage T1c, T2a, T2b, T2c, and T3a, respectively. The Gleason score was 4, 5, 6, and 7 in 5, 15, 80 and 51 patients, respectively. The initial prostate-specific antigen level was <10 or 10-20 ng/mL in 102 and 49 patients, respectively, and 42 patients had received hormonal therapy and 109 had not. The median follow-up period was 43.4 months. Acute Grade 2 rectal and bladder toxicity temporarily developed in 0.7% and 12%, respectively. Of the 147 patients who had been followed up for >2 years, the incidence of late Grade 2 or greater rectal and bladder toxicity was 2.0% (95% confidence interval, 0-4.3%) and 4.1% (95% confidence interval, 0.9-7.3%) at 2 years, respectively. Conclusion: The results of the present prospective study have revealed a valuable piece of evidence that PBT for localized prostate cancer can achieve a low incidence of late Grade 2 or greater rectal toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sterile Neutrino searches with MINOS and MINOS+

A search for sterile neutrinos was performed by looking for muon neutrino disappearance using the MINOS/MINOS+ detectors. The two detectors are at baselines of 1.04 km and 735 km from the neutrino production target of the NuMI neutrino beam at Fermilab. The data exposure consists of $10.56 \times 10^{20}$ protons-on-target from a beam configuration with a neutrino energy distribution peaked at 3 GeV and a further $5.8 \times 10^{20}$ protons-on-target in a higher energy configuration with a beam peak energy of 7 GeV. A simultaneous analysis of the $\nu_{\mu}$ charged-current and neutral- current neutrino energy spectra in the two detectors, using a $3+1$ sterile neutrino model, yields no evidence of sterile neutrino mixing. A world-leading limit on the sterile mixing angle $\sin^2 \theta_{24}$ is set for many values of the sterile neutrino mass-splitting $\Delta m^2_{41} \gt 10^{-4}\,$eV$^2$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing Nilsson states in {sup 233}U

The reaction {sup 234}U(d-vector, t){sup 233}U was measured at the Munich Q3D magnetic spectrometer with a polarized deuteron beam. The beam energy was 22 MeV, and a vector polarization of the deuterons of 80% was achieved. Angular distributions of the reaction cross section and analyzing power at seven angles between 5 deg. and 35 deg. were analyzed. Spin and parity assignments for 33 states were determined by comparison with results from distorted wave Born approximation (DWBA) calculations. Based on these assignments and energy systematics, the observed states were sorted into rotational bands. The Nilsson configurations of the bands are identified by examining the population strengths within each band. Two rotational bands with Nilsson configurations 1/2[501] and 3/2[501] could be identified for the first time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diagnosis of bubble evolution in laser-wakefield acceleration via angular distributions of betatron x-rays

We present an indirect method to diagnose the electron beam behaviors and bubble dynamic evolution in a laser-wakefield accelerator. Four kinds of typical bubble dynamic evolution and, hence, electron beam behaviors observed in Particle-In-Cell simulations are identified correspondingly by simultaneous measurement of distinct angular distributions of the betatron radiation and electron beam energy spectra in experiment. The reconstruction of the bubble evolution may shed light on finding an effective way to better generate high-quality electron beams and enhanced betatron X-rays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The microscopic state of the solar wind: Links between composition, velocity distributions, waves and turbulence

An overview is given of the microscopic state of the solar wind with emphasis on recent Ulysses high-latitude observations and previous Helios in-ecliptic observations. The possible links between composition, ionization state. velocity distribution functions of electrons, protons and heavy ions. kinetic plasma waves and MHD-scale turbulence are elaborated. Emphasis is placed on a connection of interplanetary kinetic-scale phenomena with their generating microscopic processes in the corona. The fast streams seem to consist of mesoscale pressure-balanced plasma filaments and magnetic flux tubes, reminiscent of the supergranular-size structures building the open corona, from which copious Alfven waves emanate. The wind from the magnetically structured and active corona shows developed compressive turbulence and considerable abundance and ionization state variations. Some modelling attempts to explain the observed element fractionation are briefly reviewed. The causes of the nonthermal particle features. such as proton-ion differential streaming, ion beams. temperature anisotropies, and skewed distributions associated with collisionless heat conduction, are ultimately to be searched in the fact, that the corona is never quiescent but fundamentally variable in space and time. Consequently, the radial evolution of the internal state of the wind resembles at all latitudes a complicated relaxation process, in the course of which the free (in comparison with LTE conditions) particle kinetic energy is converted into plasma waves and MHD turbulence on a wide range of scales. This leads to intermittent wave-particle interactions and unsteady anomalous transport, mixed with the weak effects of the rare Coulomb collisions. Spherical expansion and large-scale inhomogeneity forces the wind to attain microscopically a complex internal state of dynamic statistical equilibrium.

Marsch, E.↗

A high efficient relativistic backward wave oscillator with coaxial nonuniform slow-wave structure and depth-tunable extractor

A high efficient relativistic backward wave oscillator with coaxial nonuniform slow-wave structures (SWSs) and depth-tunable extractor is presented. The physical mechanism to increase the power efficiency is investigated theoretically and experimentally. It is shown that the nonuniform SWSs, the guiding magnetic field distribution, and the coaxial extractor depth play key roles in the enhancement of the beam-wave power conversion efficiency. The experimental results show that a 1.609 GHz, 2.3 GW microwave can be generated when the diode voltage is 890 kV and the beam current is 7.7 kA. The corresponding power efficiency reaches 33.6%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time-dependent simulation of prebunched one and two-beam free electron laser

A numerical simulation in one-dimension is conducted to study the slippage effects on prebunched free electron laser. A technique for the simulation of time dependent free electron lasers (FEL) to model the slippage effects is introduced, and the slowly varying envelope approximation in both z and t is used to illustrate the temporal behaviour in the prebunched FEL. Slippage effect on prebunched two-beam FEL is compared with the one-beam modeling. The evaluation of the radiation pulse energy, thermal and phase distribution, and radiation pulse shape in one-beam and two-beam modeling is studied. It was shown that the performance is considerably undermined when the slippage time is comparable to the pulse duration. However, prebunching reduces the slippage. Prebunching also leads to the radiation pulse with a single smooth spike.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scattering of a laser beam on a wet blood smear and measurement of red cell size distribution

We report an automated laser system that allows the red cell size distribution to be measured. Experiments are performed on laser light scattering by a suspension of oriented red blood cells (a wet blood smear). Based on an analysis of the angular distribution of light intensity in the diffraction pattern, we have restored the red cell size distribution. The average diameter of a red blood cell is determined with an error of less than 1%, and the spread of red blood cells in size – with an error of about 20%. We discuss the problems of photometry and processing of diffraction patterns, preparing blood samples and data processing algorithms, including methods for solving the inverse scattering problem. (laser biophotonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Possibility of using cylindrical ionization chambers for percent depth-dose measurements in clinical electron beams

Purpose: This study investigated the possibility of using cylindrical ionization chambers for percent depth-dose (PDD) measurements in high-energy clinical electron beams. Methods: The cavity correction factor, P{sub cav}, for cylindrical chambers with various diameters was calculated as a function of depth from the surface to R{sub 50}, in the energy range of 6-18 MeV electrons with the EGSnrc C ++ -based user-code CAVITY. The results were compared with those for IBA NACP-02 and PTW Roos parallel-plate ionization chambers. The effective point of measurement (EPOM) for the cylindrical chamber and the parallel-plate chamber was positioned according to the IAEA TRS-398 code of practice. The overall correction factor, P{sub Q}, and the percent depth-ionization (PDI) curve for a PTW30013 Farmer-type chamber were also compared with those of NACP-02 and Roos chambers. Results: The P{sub cav} values at depths between the surface and R{sub 50} for cylindrical chambers were all lower than those with parallel-plate chambers. However, the variation in depth for cylindrical chambers equal to or less than 4 mm in diameter was equivalent to or smaller than that for parallel-plate chambers. The P{sub Q} values for the PTW30013 chamber mainly depended on P{sub cav}, and for parallel-plate chambers depended on the wall correction factor, P{sub wall}, rather than P{sub cav}. P{sub Q} at depths from the surface to R{sub 50} for the PTW30013 chamber was consequently a lower value than that with parallel-plate chambers. However, the variation in depth was equivalent to that of parallel-plate chambers at electron energies equal to or greater than 9 MeV. The shift to match calculated PDI curves for the PTW30013 chamber and water (perturbation free) varied from 0.65 to 0 mm between 6 and 18 MeV beams. Similarly, the shifts for NACP-02 and Roos chambers were 0.5-0.6 mm and 0.2-0.3 mm, respectively, and were nearly independent of electron energy. Conclusions: Calculated PDI curves for PTW30013, NACP-02, and Roos chambers agreed well with that of water by using the optimal EPOM. Therefore, the possibility of using cylindrical ionization chambers can be expected for PDD measurements in clinical electron beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-AB-BRA-03: Calorimetry-Based Absorbed Dose to Water Measurements Using Interferometry

Purpose: Interferometry-based calorimetry is a novel technique to measure radiation-induced temperature changes allowing the measurement of absorbed dose to water (ADW). There are no mechanical components in the field. This technique also has the possibility of obtaining 2D dose distributions. The goal of this investigation is to calorimetrically-measure doses between 2.5 and 5 Gy over a single projection in a photon beam using interferometry and compare the results with doses calculated using the TG-51 linac calibration. Methods: ADW was determined by measuring radiation-induced phase shifts (PSs) of light passing through water irradiated with a 6 MV photon beam. A 9×9×9 cm{sup 3} glass phantom filled with water and placed in an arm of a Michelson interferometer was irradiated with 300, 400, 500 and 600 monitor units. The whole system was thermally insulated to achieve sufficient passive temperature control. The depth of measurement was 4.5 cm with a field size of 7×7 cm{sup 2}. The intensity of the fringe pattern was monitored with a photodiode and used to calculate the time-dependent PS curve. Data was acquired 60 s before and after the irradiation. The radiation-induced PS was calculated by taking the difference in the pre- and post-irradiation drifts extrapolated to the midpoint of the irradiation. Results were compared to computed doses. Results: Average comparison of calculated ADW values with interferometry-measured values showed an agreement to within 9.5%. k=1 uncertainties were 4.3% for calculations and 14.7% for measurements. The dominant source of uncertainty for the measurements was a temperature drift of about 30 µK/s caused by heat conduction from the interferometer’s surroundings. Conclusion: This work presented the first absolute ADW measurements using interferometry in the dose range of linac-based radiotherapy. Future work to improve measurements’ reproducibility includes the implementation of active thermal control techniques.

60 APPLIED LIFE SCIENCES↗

Fusion Materials Semiannual Progress Report for the Period Ending December 31, 2020

Three ferritic/martensitic alloys; F82H, Fe8Cr2W and CNA3 were studied for the effect of H and He on swelling. Single ion beam (Fe 2+ ), dual ion beam (Fe 2+ +He 2+ ), and triple ion beam (Fe 2+ +He 2+ +H + ) irradiations were conducted at 500°C to a damage level of 50 dpa and dual and triple beam irradiation experiments were conducted at 450°C to 50 dpa. Cavity distribution and swelling were comparable in dual ion beam and triple ion beam irradiated F82H at 500°C, indicating that the role of hydrogen in swelling in triple beam irradiated F82H appeared to be insignificant compared to the role of helium. Swelling in Fe8Cr2W and CNA3 at 500°C was approximately 3-4X greater than that at 450°C. In F82H, the average cavity size and swelling were minimally larger at 500°C than at 450°C. The significant role of hydrogen in swelling has yet to be confirmed. Future efforts will focus on separate effects experiments to understand the role of hydrogen in cavity swelling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements on wave propagation characteristics of spiraling electron beams

Dispersion characteristics of cyclotron-harmonic waves propagating on a neutralized spiraling electron beam immersed in a uniform axial magnetic field are studied experimentally. The experimental setup consisted of a vacuum system, an electron-gun corkscrew assembly which produces a 110-eV beam with the desired delta-function velocity distribution, a measurement region where a microwave signal is injected onto the beam to measure wavelengths, and a velocity analyzer for measuring the axial electron velocity. Results of wavelength measurements made at beam currents of 0.15, 1.0, and 2.0 mA are compared with calculated values, and undesirable effects produced by increasing the beam current are discussed. It is concluded that a suitable electron beam for studies of cyclotron-harmonic waves can be generated by the corkscrew device.

Singh, A.↗

Optical beam forming techniques for phased array antennas

Three optical beam forming techniques are identified as applicable to large spaceborne phased array antennas. They are 1) the fiber replacement of conventional RF phased array distribution and control components, 2) spatial beam forming, and 3) optical beam splitting techniques. Two novel optical beam forming approaches, i.e., the spatial beam forming with a 'smart pixel' spatial light modulator (SLM) and the optical beam splitting approaches are conceived with integrated quasi-optical components. Also presented are the transmit and receive array architectures with the new SLM.

Wu, Te-Kao↗

Constraint on the astrophysical 18Ne(alpha,p)21Na reaction rate through a 24Mg(p,t)22Mg measurement

The {sup 18}Ne({alpha},p){sup 21}Na reaction plays a crucial role in the ({alpha},p) process, which leads to the rapid proton capture process in x-ray bursts. The reaction rate depends upon properties of {sup 22}Mg levels above the {alpha} threshold at 8.14 MeV. Despite recent studies of these levels, only the excitation energies are known for most with no constraints on the spins. We have studied the {sup 24}Mg(p,t){sup 22}Mg reaction at the Oak Ridge National Laboratory (ORNL) Holifield Radioactive Ion Beam Facility (HRIBF), and by measuring the angular distributions of outgoing tritons, we provide some of the first experimental constraints on the spins of astrophysically important {sup 18}Ne({alpha},p){sup 21}Na resonances.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transverse Target Spin Asymmetries of Exclusive {rho}{sup 0} and {pi}{sup +} Mesons

Preliminary measurements are reported on the azimuthal single-spin asymmetries of exclusive {rho}{sup 0} and {pi}{sup +} mesons for a transversely polarized hydrogen target at HERMES using the 27.6 GeV HERA lepton beam. Within the generalized parton distribution (GPD) formalism, hard exclusive vector meson production is sensitive to GPDs H and E, while pseudo-scalar meson production is sensitive to GPDs H-tilde and E-tilde. The extracted sin({phi}-{phi}{sub s}) azimuthal amplitude of the transverse target-spin asymmetry is compared to theoretical calculations based on GPD models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phase Space Tomography Using the Cornell ERL DC Gun

The brightness and quality of electron beams in linac-based light sources are ultimately limited by the properties of the beam in the injector. It is thus important to have knowledge of the phase space distribution in addition to the rms emittance to provide an insight into high beam brightness formation mechanisms. A tomography technique has been used to reconstruct the transverse phase space of the electron beam delivered from the Cornell University ERL DC gun. The tomography diagnostic utilised three solenoid magnets directly after the DC gun and a view-screen. The injector was operated at 250keV in the emittance dominated regime, and the results showed good agreement to the phase space measured using a slit-screen method and that generated from simulation with the particle tracking code ASTRA. Comparison of various reconstruction methods is provided.

43 PARTICLE ACCELERATORS↗

Electron collisions with CO: Elastic and vibrational excitation cross sections

Absolute differential elastic and vibrational excitation cross sections up to v=11 were measured for CO in scattering angle ranges extending to 180 deg. at energies between 0.2 and 5 eV (and an elastic measurement at 10 eV). The lowest angles were 0 deg. for inelastic scattering and between 5 deg. and 20 deg. for elastic scattering, depending on energy. Integral cross sections were derived by integrating under the angular distributions and compared with previous beam and swarm measurements. The sum of the integral cross sections agrees very well with the available transmission measurements of the grand total cross section, thus validating the present measurements. The present elastic differential and integral cross sections are in excellent agreement with the best available measurement [Gibson et al., J. Phys. B 29, 3197 (1996)], but the v=1 inelastic cross section is about 25% higher. This could have consequences for simulations of cometary and planetary atmospheres.

74 ATOMIC AND MOLECULAR PHYSICS↗

The beat in laser-accelerated ion beams

Regular modulation in the ion velocity distribution becomes detectable if intense femtosecond laser pulses with very high temporal contrast are used for target normal sheath acceleration of ions. Analytical and numerical analysis of the experimental observation associates the modulation with the half-cycle of the driving laser field period. In processes like ion acceleration, the collective and laser-frequency determined electron dynamics creates strong fields in plasma to accelerate the ions. Even the oscillatory motion of electrons and its influence on the acceleration field can dominate over smoothing effects in plasma if a high temporal contrast of the driving laser pulse is given. Acceleration parameters can be directly concluded out of the experimentally observed modulation period in ion velocity spectra. The appearance of the phenomenon at a temporal contrast of ten orders between the intensity of the pulse peak and the spontaneous amplified emission background as well as remaining intensity wings at picosecond time-scale might trigger further parameter studies with even higher contrast.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗