Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Scheduling Operations for Massive Heterogeneous Clusters

High-performance computing (HPC) programming has become increasingly difficult with the advent of hybrid supercomputers consisting of multicore CPUs and accelerator boards such as the GPU. Manual tuning of software to achieve high performance on this type of machine has been performed by programmers. This is needlessly difficult and prone to being invalidated by new hardware, new software, or changes in the underlying code. A system was developed for task-based representation of programs, which when coupled with a scheduler and runtime system, allows for many benefits, including higher performance and utilization of computational resources, easier programming and porting, and adaptations of code during runtime. The system consists of a method of representing computer algorithms as a series of data-dependent tasks. The series forms a graph, which can be scheduled for execution on many nodes of a supercomputer efficiently by a computer algorithm. The schedule is executed by a dispatch component, which is tailored to understand all of the hardware types that may be available within the system. The scheduler is informed by a cluster mapping tool, which generates a topology of available resources and their strengths and communication costs. Software is decoupled from its hardware, which aids in porting to future architectures. A computer algorithm schedules all operations, which for systems of high complexity (i.e., most NASA codes), cannot be performed optimally by a human. The system aids in reducing repetitive code, such as communication code, and aids in the reduction of redundant code across projects. It adds new features to code automatically, such as recovering from a lost node or the ability to modify the code while running. In this project, the innovators at the time of this reporting intend to develop two distinct technologies that build upon each other and both of which serve as building blocks for more efficient HPC usage. First is the scheduling and dynamic execution framework, and the second is scalable linear algebra libraries that are built directly on the former.

Humphrey, John↗

Assessing overall building energy performance of a large population of residential single-family homes using limited field data

The U.S. Department of Energy (DOE), through the Building Energy Codes Program (BECP), supports building energy code development and implementation processes to achieve the maximum practicable, cost-effective improvements in energy efficiency while providing safe, healthy buildings for occupants. Currently, there is a lack of statistically representative data that shows how energy codes are implemented in the field and the energy savings opportunities that exist. To address this gap, DOE initiated a research study targeted at new residential single-family homes in 8 states starting in the fall of 2014. The study comprises of a baseline phase to determine current levels of compliance with the key energy provisions of the residential building energy code, identify issues, and calculate potential energy savings from improved compliance; a second phase implementing education, training and outreach activities designed to increase targeted code compliance; and a post-study phase to measure the impact of the training and outreach activities compared to the baseline phase. Initial analyses determined the code requirements with the largest energy impact and the minimum number of observations required to detect statistically significant differences in energy use. Data was collected in the field during a single site visit to avoid bias from repeat visits. However, the single site visit principle prevented energy simulation of individual homes due to the lack of all required model inputs. To address this, energy simulation was conducted using Pacific Northwest National Laboratory’s prototype building models and employing bootstrap random sampling on the data collected from all homes visited. The modeled energy consumption using the observed field data was evaluated relative to that associated with the minimum code requirements and potential savings associated with improved compliance of select items were assessed. This paper discusses the methodology developed for this field study, and presents the results and findings from the baseline phase.

Xie, YuLong↗

AGT100 turbomachinery

High-performance turbomachinery components have been designed and tested for the AGT100 automotive engine. The required wide range of operation coupled with the small component size, compact packaging, and low cost of production provide significant aerodynamic challenges. Aerodynamic design and development testing of the centrifugal compressor and two radial turbines are described. The compressor achieved design flow, pressure ratio, and surge margin on the initial build. Variable inlet guide vanes have proven effective in modulating flow capacity and in improving part-speed efficiency. With optimum use of the variable inlet guide vanes, the initial efficiency goals have been demonstrated in the critical idle-to-70% gasifier speed range. The gasifier turbine exceeded initial performance goals and demonstrated good performance over a wide range. The radial power turbine achieved 'developed' efficiency goals on the first build.

Tipton, D. L.↗

Valuing Energy Efficiency and Distributed Energy Resources in the Built Environment: Preprint

Traditionally, analytical frameworks that underpin building energy policy have focused on the need to reduce annual energy consumption by assessing the cost and efficiency performance of energy-consuming technologies. Investments in distributed energy resources (DERs) such as photovoltaics have generally been evaluated independently, but also on a cost and performance basis. However, buildings are rapidly evolving to incorporate technologies that not just consume energy, but also generate, store, and control energy loads. Concurrently, the electric grid is becoming more dynamic and variable due to the increased proportion electricity production from variable renewable sources. To that end, building energy policy analytical frameworks should be updated to include the interactions between energy efficiency and DERs as well as potential value streams for the grid and building owner that technologies or packages of technologies might offer. As buildings with DERs and controllable loads are able to provide grid services or optimize operations based on electricity rates and grid conditions, the temporal and spatial nature of these technologies should also be incorporated into design decisions. To explore these questions further, the National Renewable Energy Laboratory will use a series of building and electric grid models to simulate the design and operation of a neighborhood of buildings under various electricity rates, grid conditions, and potential compensation scenarios. Scenarios of time-sensitive values for future grid services will also be constructed for use in the analysis. New metrics that can be used in building energy policies will also be explored to capture the responsiveness or flexibility of high efficiency buildings with DERs under various electric grid conditions and future scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Moisture Durability Assessment of Selected Well-insulated Wall Assemblies

This report presents the results from studying the hygrothermal performance of two well-insulated wall assemblies, both complying with and exceeding international building codes (IECC 2015 2014, IRC 2015). The hygrothermal performance of walls is affected by a large number of influential parameters (e.g., outdoor and indoor climates, workmanship, material properties). This study was based on a probabilistic risk assessment in which a number of these influential parameters were simulated with their natural variability. The purpose of this approach was to generate simulation results based on laboratory chamber measurements that represent a variety of performances and thus better mimic realistic conditions. In total, laboratory measurements and 6,000 simulations were completed for five different US climate zones. A mold growth indicator (MGI) was used to estimate the risk of mold which potentially can cause moisture durability problems in the selected wall assemblies. Analyzing the possible impact on the indoor climate due to mold was not part of this study. The following conclusions can be reached from analyzing the simulation results. In a hot-humid climate, a higher R-value increases the importance of the airtightness because interior wall materials are at lower temperatures. In a cold climate, indoor humidity levels increase with increased airtightness. Air leakage must be considered in a hygrothermal risk assessment, since air efficiently brings moisture into buildings from either the interior or exterior environment. The sensitivity analysis of this study identifies mitigation strategies. Again, it is important to remark that MGI is an indicator of mold, not an indicator of indoor air quality and that mold is the most conservative indicator for moisture durability issues.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating Moisture Control of Variable-Capacity Heat Pumps in Mechanically Ventilated, Low-Load Homes in Climate Zone 2A

The well-sealed, highly insulated building enclosures constructed by today's home building industry coupled with efficient lighting and appliances are achieving significantly reduced heating and cooling loads. These low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. Even if fixed-capacity equipment can be properly specified for peak loads, it remains oversized for use during much of the year. During these part-load cooling hours, oversized equipment meets the target dry-bulb temperatures very quickly, often without sufficient opportunity for moisture control. The problem becomes more acute for high-performance houses in humid climates when meeting ASHRAE Standard 62.2 recommendations for wholehouse mechanical ventilation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prefabricated Zero Energy Retrofit Technologies: A Market Assessment

Part of the U.S. Department of Energy's (DOE) Office of Energy Efficiency and Renewable Energy’s (EERE’s) strategic goals is to stimulate the growth of a thriving domestic clean energy manufacturing industry. This report seeks to identify products in the European and U.S. markets that can enable a more integrated and standardized approach to conducting zero energy retrofits, leveraging off-site construction and manufacturing. Greater integration of energy conservation measures into prefabricated building components will further enable efficiency adoption, while reducing project complexity, risks, and costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CoNNECT: Data Analytics for Energy Efficient Communities

Energy efficiency is the lowest cost option being promoted for achieving a sustainable energy policy. Thus, there have been some innovations to reduce residential and commercial energy usage. There have also been calls to the utility companies to give customers access to timely, useful, and actionable information about their energy use, in order to unleash additional innovations in homes and businesses. Hence, some web-based tools have been developed for the public to access and compare energy usage data. In order to advance on these efforts, we propose a data analytics framework called Citizen Engagement for Energy Efficient Communities (CoNNECT). On the one hand, CoNNECT will help households to understand (i) the patterns in their energy consumption over time and how those patterns correlate with weather data, (ii) how their monthly consumption compares to other households living in houses of similar size and age within the same geographic areas, and (iii) what other customers are doing to reduce their energy consumption. We hope that the availability of such data and analysis to the public will facilitate energy efficiency efforts in residential buildings. These capabilities formed the public portal of the CoNNECT framework. On the other hand, CoNNECT will help the utility companies to better understand their customers by making available to the utilities additional datasets that they naturally do not have access to, which could help them develop focused services for their customers. These additional capabilities are parts of the utility portal of the CoNNECT framework. In this paper, we describe the CoNNECT framework, the sources of the data used in its development, the functionalities of both the public and utility portals, and the application of empirical mode decomposition for decomposing usage signals into mode functions with the hope that such mode functions could help in clustering customers into unique groups and in developing guidelines for energy conservation.

CoNNECT↗

Climate Policy and the Long-Term Evolution of the U.S. Buildings Sector

Buildings are the dominant driver of daily and seasonal electric load cycles, and account for 40 percent of U.S. final energy use. They account for roughly 10 percent of direct U.S. CO2 emissions and roughly 40 percent including indirect emissions from electricity generation. This paper explores the possible evolution of this sector over the coming century, its potential role in climate action and response to climate policies, and the potential benefits of advances in building technologies for addressing climate change. The paper presents a set of scenarios based on a detailed, service-based model of the U.S. buildings sector that is embedded within a long-term, global, integrated assessment model, MiniCAM. Eight scenarios are created in total, combining two sets of assumptions regarding U.S. building service demand growth, two sets of assumptions regarding the improvements in building energy technologies, and two assumptions regarding long-term U.S. climate action – a no-climate-action assumption and an assumption of market-based policies to reduce U.S. CO2 emissions consistent with a 450 ppmv global target. Through these eight scenarios, the paper comments on the implications of continued growth in building service demands, the ability of efficiency measures to reduce emissions, and the strong link between decarbonization of electricity generation and building sector emissions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling and analysis of heat emissions from buildings to ambient air

Heat emissions from buildings is a significant source of anthropogenic heat influencing the urban microclimate; however, they are usually oversimplified in urban climate and microclimate modeling. This study developed a bottom-up physics-based approach to calculate heat emissions from buildings to the ambient air and implemented the approach in EnergyPlus. In this work, a simple result verification was conducted by comparing the EnergyPlus simulated results against the spreadsheet calculations. Simulations covering 16 commercial building types, four climates, and two energy efficiency levels were conducted to understand and evaluate the building heat emissions and their temporal patterns as well as three major components: (1) building envelope (convective heat transfer to ambient air), (2) zones (air exfiltration and exhaust air), and (3) HVAC systems (relief air and heat rejection from condensers or cooling towers). The main findings are: (1) heat emissions are usually higher than the site energy use (about 2.5 times), and their dynamics should be considered; (2) building characteristics and their energy systems lead to differences in heat emission contributions from the three components, and their dynamics, for example, in the warehouse models, the envelope component accounts for 90.4%, while it is 12.7% for the large office models; (3) for most building typologies, the climate has a strong impact on heat emissions, for example, buildings with dominant heat emissions from the zone exhaust air and/or the HVAC reject heat, a general decrease in heat emissions in hotter climates is observed, while envelope-dominated buildings show the opposite; and (4) building technologies that reduce energy use in buildings may perform differently in reducing heat emissions. The developed heat emissions calculation method can be adopted in EnergyPlus and most other building energy modeling programs. It can provide dynamic building heat emissions as an input to urban climate computational fluid dynamics (CFD) models at a higher spatial and temporal resolution than is currently available, to improve the simulation accuracy of the urban microclimate and capture the urban heat island effect and urban overheating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Electric Space Heating in Multifamily Apartments in Juneau, Alaska [Slides]

The study objective was to understand the change in electrical consumption and cost after the addition of a ductless mini-split air-source heat pump (ASHP) across rental apartments heated by electrical resistance heating systems in multifamily buildings in Juneau, Alaska. Alaska Electric Light and Power Company (AELP), the utility in Juneau, Alaska, funded installation of 19 heat pumps across four buildings. Using electrical meter interval data, including the total apartment consumption and submeter data for each heating appliance (electric resistance baseboard and heat pump), the National Laboratory of the Rockies (NLR) calculated energy use metrics before and after heat pump installation and visualized results. Through this research, NLR compares electrical use (total and specific to heating appliances), adjusted for weather and apartment size, and electrical demand in the year before and after installation of an ASHP across study units. The results will inform the utility and residents of documented energy and cost savings from transitioning building heating systems to a higher-efficiency electricity-based appliance, deliver a basis for building energy modeling across other multifamily housing dwellings, and enable estimates of potential electricity savings to AELP grid under widespread adoption scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Building Codes and Standards: Update on Changes

Harnessing and adapting new technologies and research enables us to create a future where the built environment is healthier, more comfortable and more energy efficient, thus producing a more sustainable world. ASHRAE is able to make these contributions because of the dedication of our members, which currently is about 56,500 people globally, and that is a number we hope continues to grow. ASHRAE partners with many organizations to develop and implement impactful standards for maintaining and building a sustainable environment. These standards are designed to help make buildings more efficient and to provide best practices and resources for industry professionals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DART: distributed adaptive radix tree for efficient affix-based keyword search on HPC systems

© 2018 Association for Computing Machinery. Affix-based search is a fundamental functionality for storage systems. It allows users to find desired datasets, where attributes of a dataset match an affix. While building inverted index to facilitate efficient affix based keyword search is a common practice for standalone databases and for desktop file systems, building local indexes or adopting indexing techniques used in a standalone data store is insufficient for highperformance computing (HPC) systems due to the massive amount of data and distributed nature of the storage devices within a system. In this paper, we propose Distributed Adaptive Radix Tree (DART), to address the challenge of distributed affix-based keyword search on HPC systems. This trie-based approach is scalable in achieving efficient affix-based search and alleviating imbalanced keyword distribution and excessive requests on keywords at scale. Our evaluation at different scales shows that, comparing with the "full string hashing" use case of the most popular distributed indexing technique - Distributed Hash Table (DHT), DART achieves up to 55× better throughput with prefix search and with suffix search, while achieving comparable throughput with exact and infix searches. Also, comparing to the "initial hashing" use case of DHT, DART maintains a balanced keyword distribution on distributed nodes and alleviates excessive query workload against popular keywords.

Zhang, Wei↗

American Recovery and Reinvestment Act (ARRA) FEMP Technical Assistance - United States Pacific Command (PACOM) Guam, Task 3.3: Building Retuning Training

Document describes an onsite workshop and building retuning training conducted in Guam in August 2010. Document reports on issues identified during an audit of several buildings and recommendations to save energy throughout the site. During the workshop, it became apparent that as site personnel maintain the facilities at Guam, the following retuning efforts and strategies should be prioritized: (1) Controlling the mechanical systems operational hours and zone temperature set points appeared to present the best opportunities for savings; (2) Zone temperature set points in some buildings are excessively low, especially at night, when the zone temperatures are so cold that they approached the dewpoint; and (3) Manually-set outside air dampers are providing excessive outside air, especially for spaces that are unoccupied. Two of the larger schools, one on the Naval Base and one on Anderson AFB, are in need of a significant recommissioning effort. These facilities are relatively new, with direct digital controls (DDC) but are significantly out of balance. The pressure in one school is extremely negative, which is pulling humid air through the facility each time a door is opened. The draft can be felt several feet down the halls. The pressure in the other school is extremely positive relative to the outside, and you can stand 20-feet outside and still feel cool drafts of air exiting the building. It is recommended that humidity sensors be installed in all new projects and retrofitted into exist facilities. In this humid climate, control of humidity is very important. There are significant periods of time when the mechanical systems in many buildings can be unloaded and dehumidification is not required. The use of CO{sub 2} sensors should also be considered in representative areas. CO{sub 2} sensors determine whether spaces are occupied so that fresh air is only brought into the space when needed. By reducing the amount of outside air brought into the space, the humidity load is also substantially reduced. CO{sub 2} and humidity sensors, combined with outside air sensors, can be used to predict whether conditions are amenable to mold growth and to automatically adjust systems to help prevent mold without using extra energy. The goal of this training is to give the building operators the knowledge needed to make positive changes in the operation of building systems. As class participants apply this knowledge, building systems will run more efficiently, occupant comfort should improve, while saving energy and reducing greenhouse gas emissions.

54 ENVIRONMENTAL SCIENCES↗