Infrared reflectance spectra of Na2S with contaminant Na2CO3 - Effects of adsorbed H2O and CO2 and relation to studies of Io

A previously reported laboratory determination of the IR spectrum of Na2S is presently noted to have been incorrectly interpreted, due to the inadvertent contamination of the sample with Na2CO3. New Na2S spectra are presented, and the Na2CO3 spectrum is examined in order to demonstrate that this phase is the primary sample contaminant. Na2S is a candidate surface component on the Jupiter satellite, Io, in view of its apparent high IR brightness and spectral neutrality in the 1-5 micron range.

Nash, Douglas B.↗

Self-contained space qualifiable optical contamination monitor

Experiments operating in the VUV as well as those employing cryocooled optical surfaces are the most seriously affected by spacecraft contamination due to outgassing of foreign materials, reaction byproducts of thruster firings, system venting emissions, etc. Attention is presently given to a self-contained optical contamination monitor, furnishing in-flight and/or real-time monitoring of VUV reflectivity and transmittance. The time-lining of measurement results with other spacecraft events will allow the direct evaluation of spacecraft operation effects on critical optical surfaces.

Jarratt, R. V., Jr.↗

Effects of water-contaminated air on blowoff limits of opposed jet hydrogen-air diffusion flames

The effects of water-contaminated air on the extinction and flame restoration of the central portion of N2-diluted H2 versus air counterflow diffusion flames are investigated using a coaxial tubular opposed jet burner. The results show that the replacement of N2 contaminant in air by water on a mole for mole basis decreases the maximum sustainable H2 mass flow, just prior to extinction, of the flame. This result contrasts strongly with the analogous substitution of water for N2 in a relatively hot premixed H2-O2-N2 flame, which was shown by Koroll and Mulpuru (1986) to lead to a significant, kinetically controlled increase in laminar burning velocity.

Pellett, Gerald L.↗

The effects of contamination on gaseous X-ray detectors

Results are presented which detail how the performance of a proportional counter degrades when oxygen is added as a contaminant. It is demonstrated that argon based gas fillings are much less sensitive to electronegative impurities than are xenon filled detectors which can show significant deterioration for contamination levels as low as 10 ppm. The data are particularly relevant to X-ray astronomy, where sealed systems must operate for long periods of time.

Ramsey, B. D.↗

Spectrograph Measures Contamination Of Optical Elements

Scanning-monochromator spectrograph designed to measure contamination on surfaces of optical elements as function of time. Repeatedly exposes samples to environment, then measures their transmittances or reflectances over range of wavelengths. Intended for use at vacuum-ultraviolet wavelengths to evaluate effects of outgassing, heating, and cooling on optical instruments. Principle of operation also applicable to spectral monitoring of time-dependent contamination at other wavelengths and in laboratory, industrial, or other settings.

Flint, Bruce K.↗

Contamination control requirements document JSC 30426 recommended updates

Contamination control requirements for the Space Station have been evolving over the last few years. Workshops, comments by experimenters and continuing analysis have resulted in recommending changes to the November 19, 1986 version of Space Station External Contamination Control Requirements, JSC 30426. These are summarized and presented, so that the requirements can be revised as soon as possible, to minimize costly design impacts on the Space Station.

Rantanen, Ray↗

The possible contamination of Jupiter

The Galileo probe, though at present its future is uncertain, would, if not sterilized, represent a good chance of contaminating Jupiter. Most scientists opposed to sterilizing the probe argue that to order the probe sterilized would be the death of the project, since sterilization would entail a reconstruction of the probe, and there are not enough funds to accomplish this. These scientists, however, are ignoring a relatively simple and inexpensive alternative to the traditional heat sterilization method. The main threat of contamination comes from Galileo's exterior surfaces: the shell of the probe and its parachute. The probe innermost components would not represent a threat since the probe is sealed. In light of the fact that only the exterior of Galileo would have to be sterilized, heat would not have to be used as a method of sterilization. Instead, various gas mixtures could be sprayed entirely over the probe and its parachute, gases which would kill any and all bacteria. This idea is more thoroughly examined.

Garcia, Joe↗

Contamination effects of GPS Navstar solar array performance

The solar arrays on Navstars 1 to 6 have been limiting the electrical power capabilities in the extended life (beyond the 5 year design life). The departure from predicted performance consists of an extra 2.5 percent per year degradation beyond the radiation model estimates. This degradation is unusual in showing a linear rather than exponential decay with time. The performance of the arrays on these satellites has been examined in order to predict future behavior and to make refined projections on the Navstar 7 to 11 solar arrays. Evidence obtained from flight experiments on Navstar 5 and 6, and from laboratory experiments, suggests that contamination of the solar arrays while on orbit may be responsible. The evidence for photo-induced contamination of spacecraft surfaces is presented, and the effect on solar array output in the case of the GPS satellites is shown to be consistent with the observed anomalies.

Marvin, Dean C.↗

Contamination effects study

The in-situ optical surface measurement system is a facility designed to study the deleterious effects of particulate materials on the surface reflectivities of optical materials in the vacuum ultraviolet (VUV). This arrangement is designed to simulate the on-orbit effects of contamination and degradation of optical surfaces. This simulation is accomplished through the use of non-coherent VUV sources illuminating optical surfaces located in a high vacuum chamber. Several sources of contamination are employed. The reflectivity is measured both at the specular reflection as well as at two scattered positions, forward and reverse. The system components are described and an operating procedure is given.

Source record↗

Prospects for a contamination-free ultravacuum facility in low-earth orbit

The old concept of using the wake of a spacecraft to obtain an ultrahigh vacuum is revisited. A wakeshield can be configured so that a surface of interest does not subtend any walls that could become contaminated, thus it should be possible to achieve a contamination-free, ultrahigh vacuum capability with infinite pumping speed even in the presence of high heat loads and moderate gas loads. This papar analyzes the conceptual design for a Space Ultravacuum Research Facility (SURF), both in a shuttle-attached mode and as a free flyer. It is shown that even in the shuttle-attached mode, it should be possible to obtain vacuum levels equivalent to 10 to the -9th to 10 to the -10th Torr with O and N2 as the primary constituents. As a free flyer the SURF will be limited primarily by the gas load from the process being performed. For chemical beam epitaxy it is shown that equivalent vacuum levels of 10 to the -14th Torr should be possible at 300 km.

Naumann, Robert J.↗

Noise-Contamination Detector

Deviations in periods of output from tracking filter measured. Signal-analyzing system measures degree to which sinusoid contaminated by noise. Noise-contamination detector indirectly measures noise in noisy sinusoidal signal by measuring average value of fractional absolute dither in period of signal. Developed to measure noise in outputs of vibration sensors used to test bearings and other components of rotating machinery.

Randall, Richard L.↗

X-Ray Fluorescence Surface-Contamination Detector

X-ray spectrum of contaminating element reveals presence. Proposed x-ray fluorescence spectrometer used to detect thin layer of Conoco HD-2 (or equivalent) grease on D6-ac steel. Source-and-detector assembly mounted on remote manipulator with other contamination-detecting equipment and scanned across surface of specimen. Output of detector fed through coaxial cable to standard pulse-height-analyzing equipment and processed further by small computer to obtain x-ray energy spectrum.

Eldridge, Hudson B.↗

Concentrating Gaseous Contaminants For Monitoring

Apparatus concentrates contaminants outgassing from specimens in vacuum and passes concentrated contaminants to gas-chromatography/mass-spectrometry system for analysis. Cold wall of collection chamber adsorbs gases from specimen in isothermal cell. When wall heated, plate desorbs gases so they can be analyzed. Collection chamber maintained at low pressure throughout adsorption and desorption process. Determines whether candidate materials for use in vacuum environments generate harmful substances.

Mahone, William C.↗

The rodent research animal holding facility as a barrier to environmental contamination

The rodent Research Animal Holding Facility (RAHF), developed by NASA Ames Research Center (ARC) to separately house rodents in a Spacelab, was verified as a barrier to environmental contaminants during a 12-day biocompatibility test. Environmental contaminants considered were solid particulates, microorganisms, ammonia, and typical animal odors. The 12-day test conducted in August 1988 was designed to verify that the rodent RAHF system would adequately support and maintain animal specimens during normal system operations. Additional objectives of this test were to demonstrate that: (1) the system would capture typical particulate debris produced by the animal; (2) microorganisms would be contained; and (3) the passage of animal odors was adequately controlled. In addition, the amount of carbon dioxide exhausted by the RAHF system was to be quantified. Of primary importance during the test was the demonstration that the RAHF would contain particles greater than 150 micrometers. This was verified after analyzing collection plates placed under exhaust air ducts and rodent cages during cage maintenance operations, e.g., waste tray and feeder changeouts. Microbiological testing identified no additional organisms in the test environment that could be traced to the RAHF. Odor containment was demonstrated to be less than barely detectable. Ammonia could not be detected in the exhaust air from the RAHF system. Carbon dioxide levels were verified to be less than 0.35 percent.

Savage, P. D., Jr.↗

Spacecraft external molecular contamination analysis

Control of contamination on and around spacecraft is required to avoid adverse effects on the performance of instruments and spacecraft systems. Recent work in this area is reviewed and discussed. Specific issues and limitations to be considered as part of the effort to predict contamination effects using modeling techniques are addressed. Significant results of Space Shuttle missions in the field of molecule/surface interactions as well as their implications for space station design and operation are reviewed.

Ehlers, H. K. F.↗

Satellite material contaminant optical properties

The Air Force Wright Research and Development Center and the Arnold Engineering Development Center are continuing a program for measuring optical effects of satellite material outgassing products on cryo-optic surfaces. Presented here are infrared (4000 to 700 cm(-1)) transmittance data for contaminant films condensed on a 77 K geranium window. From the transmittance data, the contaminant film refractive and absorptive indices (n, k) were derived using an analytical thin-film interference model with a nonlinear least-squares algorithm. To date 19 materials have been studied with the optical contents determined for 13 of those. The materials include adhesives, paints, composites, films, and lubricants. This program is continuing and properties for other materials will be available in the future.

Wood, B. E.↗

Planetary protection and back contamination control for a Mars rover sample return mission

A commitment to avoid the harmful contamination of outer space and avoid adverse changes in the environment of the earth has been long reflected in NASA's Planetary Protection policy. Working under guidelines developed by the Committee on Space Research (COSPAR), NASA has implemented the policy in an interactive process that has included the recommendations of the U.S. National Academy of Sciences. Measures taken to prevent the contamination of earth during the Apollo missions were perhaps the most visible manifestations of this policy, and provided numerous lessons for future sample return opportunities. This paper presents the current status of planetary protection policy within NASA, and a prospectus on how planetary protection issues might be addressed in relation to a Mars Rover Sample Return mission.

Rummel, John D.↗

The rodent Research Animal Holding Facility as a barrier to environmental contamination

The rodent Research Animal Holding Facility (RAHF), developed by NASA Ames Research Center (ARC) to separately house rodents in a Spacelab, was verified as a barrier to environmental contaminants during a 12-day biocompatibility test. Environmental contaminants considered were solid particulates, microorganisms, ammonia, and typical animal odors. The 12-day test conducted in August 1988 was designed to verify that the rodent RAHF system would adequately support and maintain animal specimens during normal system operations. Additional objectives of this test were to demonstrate that: (1) the system would capture typical particulate debris produced by the animal; (2) microorganisms would be contained; and (3) the passage of animal odors was adequately controlled. In addition, the amount of carbon dioxide exhausted by the RAHF system was to be quantified. Of primary importance during the test was the demonstration that the RAHF would contain particles greater than 150 micrometers. This was verified after analyzing collection plates placed under exhaust air ducts and and rodent cages during cage maintenance operations, e.g., waste tray and feeder changeouts. Microbiological testing identified no additional organisms in the test environment that could be traced to the RAHF. Odor containment was demonstrated to be less than barely detectable. Ammonia could not be detected in the exhaust air from the RAHF system. Carbon dioxide levels were verified to be less than 0.35 percent.

Savage, P. D., Jr.↗