Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Lidar Mapping and Surveillance of Nuclear Infrastructure

Wear is unavoidable, whether it occurs in a nuclear facility or abridge on the highway its detection is crucial to preventing the failure of a system. While tools capable of detecting localized damage exist, industry lacks methods to evaluate the health of larger infrastructure. Routine inspection of nuclear facilities must be undertaken to ensure the safety of personnel and proper containment of nuclear materials. Most systems in a nuclear facility are designated as radioactive and confined spaces. To constantly monitor such systems in person would be hazardous but with a remote inspection tool it can be done in a safer and easier way. Lidar: Operates by emitting a laser pulse and looking for the reflected light. Allows user to gain 3D information of the environment. Project Objective: To develop an inspection tool for evaluating the health of large scale infrastructure using Lidar and machine learning. Autonomous Platform + Lidar + Data Fusion + Big Data. Use SLAM to build a 2D map of the environment. Point cloud created by transforming the points between reference frames. Point cloud to Surface: Inherent representation of surface geometry; Difficult to process with conventional techniques. Point cloud to Image: Easily processed by conventional machine learning algorithms. The quantity of data generated will necessitate a big data framework to manage the data for processing. Additional Sensors: Detecting the temperature (a) chemical makeup (b) and radiation emission (c) of a surface could assist in detecting problems. Human inspection can detect irregularities in both physical objects and their point-cloud representations. This is a good indication that mapping nuclear sites using Lidar will provide qualitative insight into the health of the facility. If deep learning can be used to automatically identify problem areas then the completed tool could become an invaluable asset.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nanoscale chemical imaging using synchrotron x-ray enhanced scanning tunneling microscopy

The combination of synchrotron radiation with scanning tunneling microscopy provides a promising new concept for chemical imaging of nanoscale structures. It employs detection of local x-ray absorption, which directly yields chemical, electronic, and magnetic sensitivity. The study of the tip current in the far field (800 nm tip/sample separation) shows that insulator-coated tips have to be considered in order to reduce the background from stray photoelectron. A picture of the different channels contributing to the x-ray enhanced STM process is proposed. If during electron tunneling the sample is illuminated with monochromatic x-rays, characteristic absorption will arise, and core electrons are excited, which might modulate the conventional tunnel current and facilitate chemical imaging at the nanoscale.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design Features of a Planar Hybrid/Permanent Magnet Strong Focusing Undulator for Free Electron Laser (FEL) And Synchrotron Radiation (SR) Applications

Insertion devices for Angstrom-wavelength Free Electron Laser (FEL) amplifiers driven by multi-GeV electron beams generally require distributed focusing substantially stronger than their own natural focusing fields. Over the last several years a wide variety of focusing schemes and configurations have been proposed for undulators of this class, ranging from conventional current-driven quadrupoles external to the undulator magnets to permanent magnet (PM) lattices inserted into the insertion device gap. In this paper we present design studies of a flexible high-field hybrid/PM undulator with strong superimposed planar PM focusing proposed for a 1.5 Angstrom Linac Coherent Light Source (LCLS) driven by an electron beam with a 1 mm-mr normalized emittance. Attainable field parameters, tuning modes, and potential applications of the proposed structure are discussed.

43 PARTICLE ACCELERATORS↗

Isolated-attosecond-pulse generation with infrared double optical gating

We propose and theoretically demonstrate an infrared two-color polarization gating scheme for generating an intense isolated attosecond pulse (IAP) in the multicycle regime. Our simulations show that an IAP can be produced using a multicycle two-color driving pulse with a duration up to 60 fs. Moreover, the carrier-envelope phase (CEP) of the driving laser is not required to be stabilized, although the IAP intensity changes with the CEP slip. Such a gating scheme significantly relaxes the requirements for driving lasers and opens the door to easily create intense IAPs with a high-power conventional multicycle laser pulse.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-C-17A-07: FusionARC Treatment with Adaptive Beam Selection Method

Purpose: Recently, a new treatment scheme, FusionARC, has been introduced to compensate for the pitfalls in single-arc VMAT planning. It basically allows for the static field treatment in selected locations, while the remaining is treated by single-rotational arc delivery. The important issue is how to choose the directions for static field treatment. This study presents an adaptive beam selection method to formulate fusionARC treatment scheme. Methods: The optimal plan for single-rotational arc treatment is obtained from two-step approach based on the reweighted total-variation (TV) minimization. To choose the directions for static field treatment with extra segments, a value of our proposed cost function at each field is computed on the new fluence-map, which adds an extra segment to the designated field location only. The cost function is defined as a summation of equivalent uniform dose (EUD) of all structures with the fluence-map, while assuming that the lower cost function value implies the enhancement of plan quality. Finally, the extra segments for static field treatment would be added to the selected directions with low cost function values. A prostate patient data was applied and evaluated with three different plans: conventional VMAT, fusionARC, and static IMRT. Results: The 7 field locations, corresponding to the lowest cost function values, are chosen to insert extra segment for step-and-shoot dose delivery. Our proposed fusionARC plan with the selected angles improves the dose sparing to the critical organs, relative to static IMRT and conventional VMAT plans. The dose conformity to the target is significantly enhanced at the small expense of treatment time, compared with VMAT plan. Its estimated treatment time, however, is still much faster than IMRT. Conclusion: The fusionARC treatment with adaptive beam selection method could improve the plan quality with insignificant damage in the treatment time, relative to the conventional VMAT.

60 APPLIED LIFE SCIENCES↗

Migdal and his theory in Juelich

We review the application of Migdal's Theory of Finite Fermi Systems to the structure of deformed nuclei, approaches beyond the conventional linear response, and microscopic calculations of the Migdal-parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of a Xe dopant on an Ar gas-puff implosion on Z

Two Ar gas-puff experiments, each using loads consisting of two annuli and a center jet, were recently performed on Sandia National Laboratories' Z machine. These shots had the same load except that one of them (Z2603) employed a Xe dopant of 0.8% by number in the jet, which was not present in the otherwise identical Z2605. The extensive diagnostics deployed in these experiments reveal that the presence of this small fraction of Xe had a significant effect on the emitted K-shell radiation. Use of the Xe dramatically reduced the Ar K-shell yield from 373 ± 9% to 129 ± 9% kJ. However, the total yield increased, from 1.02 ± 17% to 1.14 ± 17% MJ. Also, the K-shell power pulse for Z2603 exhibited two nearly equal peaks separated by ∼5 ns, but that of Z2605 consisted of a more conventional single peak. Analysis of time- and space resolved K-shell spectra using a detailed atomic model for Ar ions indicates that a much greater fraction of the load mass was heated to the K-shell in the non-Xe shot Z2605. Previous average-ion atomic calculations of Xe cooling rates [Post et al., At. Data Nucl. Data Tables 20, 397 (1977)] show that the radiative cooling of the small 0.8% Xe fraction is nonetheless significant compared to that of the Ar and is therefore likely responsible for the differences in the shots.

Apruzese, J. P.↗

New BNL 3D-Trench Electrode Si Detectors for Radiation Hard Detectors for sLHC and for X-ray Applications

A new international-patent-pending (PCT/US2010/52887) detector type, named here as 3D-Trench electrode Si detectors, is proposed in this work. In this new 3D electrode configuration, one or both types of electrodes are etched as trenches deep into the Si (fully penetrating with SOI or supporting wafer, or non-fully penetrating into 50-90% of the thickness), instead of columns as in the conventional ('standard') 3D electrode Si detectors. With trench etched electrodes, the electric field in the new 3D electrode detectors are well defined without low or zero field regions. Except near both surfaces of the detector, the electric field in the concentric type 3D-Trench electrode Si detectors is nearly radial with little or no angular dependence in the circular and hexangular (concentric-type) pixel cell geometries. In the case of parallel plate 3D trench pixels, the field is nearly linear (like the planar 2D electrode detectors), with simple and well-defined boundary conditions. Since each pixel cell in a 3D-Trench electrode detector is isolated from others by highly doped trenches, it is an electrically independent cell. Therefore, an alternative name 'Independent Coaxial Detector Array', or ICDA, is assigned to an array of 3D-Trench electrode detectors. The electric field in the detector can be reduced by a factor of nearly 10 with an optimal 3D-Trench configuration where the junction is on the surrounding trench side. The full depletion voltage in this optimal configuration can be up to 7 times less than that of a conventional 3D detector, and even a factor of two less than that of a 2D planar detector with a thickness the same as the electrode spacing in the 3D-Trench electrode detector. In the case of non-fully penetrating trench electrodes, the processing is true one-sided with backside being unprocessed. The charge loss due to the dead space associated with the trenches is insignificant as compared to that due to radiation-induced trapping in sLHC environment. Since the large electrode spacing (up to 500 {micro}m) can be realized in the 3D-Trench electrode detector due to their advantage of greatly reduced full depletion voltage, detectors with large pixel cells (therefore small dead volume) can be made for applications in photon science (e.g. X-ray).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multistatic Aerosol Cloud Lidar in Space: A Theoretical Perspective

Accurate aerosol and cloud retrievals from space remain quite challenging and typically involve solving a severely ill-posed inverse scattering problem. In this Perspective, we formulate in general terms an aerosol and aerosol-cloud interaction space mission concept intended to provide detailed horizontal and vertical profiles of aerosol physical characteristics as well as identify mutually induced changes in the properties of aerosols and clouds. We argue that a natural and feasible way of addressing the ill-posedness of the inverse scattering problem while having an exquisite vertical-profiling capability is to fly a multistatic (including bistatic) lidar system. We analyze theoretically the capabilities of a formation-flying constellation of a primary satellite equipped with a conventional monostatic (backscattering) lidar and one or more additional platforms each hosting a receiver of the scattered laser light. If successfully implemented, this concept would combine the measurement capabilities of a passive multi-angle multi-spectral polarimeter with the vertical profiling capability of a lidar; address the ill-posedness of the inverse problem caused by the highly limited information content of monostatic lidar measurements; address the ill-posedness of the inverse problem caused by vertical integration and surface reflection in passive photopolarimetric measurements; relax polarization accuracy requirements; eliminate the need for exquisite radiative-transfer modeling of the atmosphere-surface system in data analyses; yield the day-and-night observation capability; provide direct characterization of ground-level aerosols as atmospheric pollutants; and yield direct measurements of polarized bidirectional surface reflectance. We demonstrate, in particular, that supplementing the conventional backscattering lidar with just one additional receiver flown in formation at a scattering angle close to 170deg can dramatically increase the information content of the measurements. Although the specific subject of this Perspective is the multistatic lidar concept, all our conclusions equally apply to a multistatic radar system intended to study from space the global distribution of cloud and precipitation characteristics.

aerosols↗

SU-F-T-472: Validation of Absolute Dose Measurements for MR-IGRT With and Without Magnetic Field

Purpose: To validate absolute dose measurements for a MR-IGRT system without presence of the magnetic field. Methods: The standard method (AAPM’s TG-51) of absolute dose measurement with ionization chambers was tested with and without the presence of the magnetic field for a clinical 0.32-T Co-60 MR-IGRT system. Two ionization chambers were used - the Standard Imaging (Madison, WI) A18 (0.123 cc) and the PTW (Freiburg, Germany). A previously reported Monte Carlo simulation suggested a difference on the order of 0.5% for dose measured with and without the presence of the magnetic field, but testing this was not possible until an engineering solution to allow the radiation system to be used without the nominal magnetic field was found. A previously identified effect of orientation in the magnetic field was also tested by placing the chamber either parallel or perpendicular to the field and irradiating from two opposing angles (90 and 270). Finally, the Imaging and Radiation Oncology Core provided OSLD detectors for five irradiations each with and without the field - with two heads at both 0 and 90 degrees, and one head at 90 degrees only as it doesn’t reach 0 (IEC convention). Results: For the TG-51 comparison, expected dose was obtained by decaying values measured at the time of source installation. The average measured difference was 0.4%±0.12% for A18 and 0.06%±0.15% for Farmer chamber. There was minimal (0.3%) orientation dependence without the magnetic field for the A18 chamber, while previous measurements with the magnetic field had a deviation of 3.2% with chamber perpendicular to magnetic field. Results reported by IROC for the OSLDs with and without the field had a maximum difference of 2%. Conclusion: Accurate absolute dosimetry was verified by measurement under the same conditions with and without the magnetic field for both ionization chambers and independently-verifiable OSLDs.

60 APPLIED LIFE SCIENCES↗

Design comparison of lunar return configurations

Parabolic manned re-entry design comparisons are made between two classes of slender and blunt configurations capable of conventional horizontal and vertical earth landings. Aerodynamic modulation using flaps and control augmentation requirements are discussed in terms of their effect upon re-entry trajectories and landing footprints. Within the environment defined by the re-entry trajectories, the convective and radiative modes of heat transfer are compared, their differences discussed, and the problems associated with the configurations for planetary return missions indicated. Thermal protection systems are discussed and the factors influencing the selection of a given system for the re-entry environment are indicated. Comparison between reflective and absorptive systems are made and the merits of each for a given flight time indicated. A thermo-structural analysis is presented which shows the trade-oft between structural operating temperature and heat protection system thickness requirements. Total heat shield and structural weights are compared for the landing footprints presented and their variation with range shown. Finally, the areas of uncertainty in the aero-thermo structural design analysis are indicated for each class of configuration studied, and the weight differences between conventional horizontal landing and vertical descent configurations are given.

Parabolic flight↗

Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic and lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter, and {approx}3-4 lower at the exit side). The in-room dose (microsievert) per unit scan dose (milligray) ranged from {approx}21 {mu}Sv/mGy on average at tableside to {approx}0.1 {mu}Sv/mGy at 2.0 m distance to isocenter. All protocols involve surgical staff stepping behind a shield wall for each CBCT scan, therefore imparting {approx}zero dose to staff. Protocol implementation in preclinical cadaveric studies demonstrate integration of the C-arm with a navigation system for spine surgery guidance-specifically, minimally invasive vertebroplasty in which the system provided accurate guidance and visualization of needle placement and bone cement distribution. Cumulative dose including multiple intraoperative scans was {approx}11.5 mGy for CBCT-guided thoracic vertebroplasty and {approx}23.2 mGy for lumbar vertebroplasty, with dose to staff at tableside reduced to {approx}1 min of fluoroscopy time ({approx}40-60 {mu}Sv), compared to 5-11 min for the conventional approach. Conclusions: Intraoperative CBCT using a high-performance mobile C-arm prototype demonstrates image quality suitable to guidance of spine surgery, with task-specific protocols providing an important basis for minimizing radiation dose, while maintaining image quality sufficient for surgical guidance. Images demonstrate a significant advance in spatial resolution and soft-tissue visibility, and CBCT guidance offers the potential to reduce fluoroscopy reliance, reducing cumulative dose to patient and staff. Integration with a surgical guidance system demonstrates precise tracking and visualization in up-to-date images (alleviating reliance on preoperative images only), including detection of errors or suboptimal surgical outcomes in the operating room.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetostatic and magnetohydrodynamic modeling of planar wire arrays

For the past 2 years the planar wire array loads have proven their ability to create powerful x-ray radiation sources at the pulsed power facilities with the current level ranging from 1 to 3 MA. Several key features of the implosion and ablation dynamics of the planar wire arrays distinguish them from the wire arrays of the conventional cylindrical design. The uneven current partition through the array wires in planar geometry results in a significant difference between the ablation rates of the outermost and the innermost array wires. This difference is even higher in a double row planar array geometry. According to the three-dimensional magnetohydrodynamic simulations the effect of the delayed ablation of the inner array wires can result in effective mitigation of the Rayleigh-Taylor instability modes. The high number (200-300) of wires in a cylindrical array is preferable to ensure fine azimuthal symmetry of an array implosion. However this requirement is not a great concern for the planar wire array loads, which implode along the plane of wires. Hence, the low-wire-number planar array loads are naturally optimized for the Z-pinch experiments at short pulse (100 ns) 1 MA facilities. The application of planar wire array loads at high current accelerators is attractive for the purposes of the inertial confinement fusion because of the relative compactness of these loads and their potential for radiation pulse shaping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coupled Gel/Seeded Growth of Cs2AgBiBr6 Single Crystals for Radiation Detection

Abstract— The all-inorganic lead free Cs2AgBiBr6 perovskite represents a highly promising environment-friendly radiation detector material. The first attempt to grow Cs2AgBiBr6 single crystals using the unique gel growth method is reported in this study. This technique enables controlled reagent diffusion in a gel medium at room temperature, fostering the growth of visible single crystals. It offers advantages over conventional methods, leading to fewer equilibrium and non-equilibrium defects and simplified execution. Interestingly, the as-grown crystals exhibited variations in size and colors within the gel matrix, indicating the influence of Bi solutes in Bi-poor and Bi-rich Cs2AgBiBr6 crystals. Once the crystals were confirmed by powder xray diffraction, a series of comprehensive material characterizations was performed. The resistivity of Cs2AgBiBr6 single crystals was measured at 1.12x107 Ω•cm. Trap density analysis yielded a value of 2.82 x1010 cm-3. The charge carrier mobility was determined to be 32.9 cm2V-1S-1, suggesting the suitability for radiation detector applications. Additional growth optimization is going on and further characterization will be reported during the presentation. Our work helps accelerate the development of lead-free perovskite materials toward radiation detector applications.

James, Ralph B.↗

Beyond cancer treatment – a review of total lymphoid irradiation for heart and lung transplant recipients

Immunosuppressive drugs used in the management of heart and lung transplants have a large monetary and quality of life cost due to their side effects. Total lymphoid irradiation (TLI) is one method of minimising the need for or replacing post-operative immunosuppressive drugs. A literature review was conducted on electronic databases using defined search terms. The aim was to establish the indications for the use of TLI, its advantages and disadvantages and the weaknesses associated with the methods used in related research. Eight articles were located that focused on TLI usage in combating organ rejection. These studies identified that the use of TLI resulted in a reduction in early rejection. One study reported a drop in rejection episodes from 0.46 to 0.14 episodes per patient per month once the TLI was complete. While the short-term prognosis is excellent, the long-term outlook is less positive with an increased risk of organ rejection and myelodysplasia 3.5 years post-TLI. This review reminds us that radiation therapy (RT) is not exclusively indicated for cancer treatment. While TLI cannot replace immunosuppressive drug therapy, it can offer a treatment option for people that cannot tolerate immunosuppressive drugs, or when conventional anti-rejection treatment is no longer viable. Reported long-term complications suggest that TLI should be used with caution. However, this modality should not be overlooked in cases of chronic rejection. Further research is required to establish the efficacy of RT in the treatment of transplant patients who are unsuitable for drug-based anti-rejection therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PhaseT3M: 3D imaging at 1.6 Å resolution via electron cryo-tomography with nonlinear phase retrieval

Electron cryo-tomography (cryo-ET) enables 3D imaging of complex, radiation-sensitive structures with molecular detail. However, image contrast from the interference of scattered electrons is nonlinear with atomic density and multiple scattering further complicates interpretation. These effects degrade resolution, particularly in conventional reconstruction algorithms, which assume linearity. Particle averaging can reduce such issues but is unsuitable for heterogeneous or dynamic samples ubiquitous in biology, chemistry, and materials sciences. Here, we develop a phase retrieval-based cryo-ET method, PhaseT3M. We experimentally demonstrate its application to an approximately 7 nm Co3O4 nanoparticle on an approximately 30 nm carbon substrate, achieving a maximum resolution of 1.6 Å, surpassing conventional limits using standard cryo-TEM equipment. PhaseT3M uses a multislice model for multiple scattering and Bayesian optimization for alignment and computational aberration correction, with a positivity constraint to recover ‘missing wedge’ information. Applied directly to biological particles, it enhances reconstruction quality and reduces artifacts, establishing a standard for routine 3D imaging with phase contrast.

Biophysics↗

An ultra-high gain and efficient amplifier based on Raman amplification in plasma

Raman amplification arising from the excitation of a density echelon in plasma could lead to amplifiers that significantly exceed current power limits of conventional laser media. Here we show that 1–100 J pump pulses can amplify picojoule seed pulses to nearly joule level. The extremely high gain also leads to significant amplification of backscattered radiation from “noise”, arising from stochastic plasma fluctuations that competes with externally injected seed pulses, which are amplified to similar levels at the highest pump energies. The pump energy is scattered into the seed at an oblique angle with 14 J sr -1 , and net gains of more than eight orders of magnitude. The maximum gain coefficient, of 180 cm -1 , exceeds high-power solid-state amplifying media by orders of magnitude. The observation of a minimum of 640 J sr -1 directly backscattered from noise, corresponding to ≈10% of the pump energy in the observation solid angle, implies potential overall efficiencies greater than 10%.

42 ENGINEERING↗

Bio-inspired multiscale design for perovskite solar cells

Metal halide perovskite semiconductors have attractive light-harvesting and charge-carrier transport properties for photovoltaics. Perovskite solar cells (PSCs) and modules have demonstrated their commercial promise with high power conversion efficiencies, but still face stability challenges. In this Review, we explore how biomaterials offer design inspiration for the development of durable and efficient PSCs at three different scales. At the molecular level, bio-inspired molecular interactions are harnessed towards crystallization control and degradation prevention, which offers an enhancement in long-term maximum-power-point tracking stability. At the microstructural level, self-healing and strength-enhancing strategies, utilizing dynamic bonds and interfacial reinforcement, can help PSCs to recover from physical damage and maintain high performance. At the device level, macroscopic functionalities, such as moth-eye-inspired structures tailored to different layers, can collectively enable antireflection, radiative cooling and self-cleaning to optimize light management, heat dissipation and encapsulation in PSCs. Bio-inspired PSC research can combine improved efficiency and lifetime, with abundant, biocompatible alternatives to conventional stabilizers. Future efforts should focus on screening bioinspired molecules to optimize film crystallization and stability, developing self-healing mechanisms triggered by operational stress, designing cost-efficient biomicrostructures, and integrating multifunctional encapsulation to enhance the efficiency and lifespan of PSCs.

Duan, Tianwei↗