Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

The New Sun-Sky-Lunar Cimel CE318-T Multiband Photometer - A Comprehensive Performance Evaluation

This paper presents the new photometer CE318-T, able to perform daytime and night-time photometric measurements using the sun and the moon as light source. Therefore,this new device permits a complete cycle of diurnal aerosol and water vapour measurements valuable to enhance atmospheric monitoring to be extracted. In this study wehave found significantly higher precision of triplets when comparing the CE318-T master instrument and the Cimel AErosol RObotic NET work (AERONET) master (CE318-AERONET) triplets as a result of the new CE318-T tracking system. Regarding the instrument calibration, two new methodologies to transfer the calibration from a reference instrument using only daytime measurements (Sun Ratio and Sun-Moon gain factor techniques) are presented and discussed. These methods allow the reduction of the previous complexities inherent to nocturnal calibration. A quantitative estimation of CE318-T AOD uncertainty by means of error propagation theory during daytime revealed AOD uncertainties (u(sup D)(sub AOD)) for Langley-calibrated instruments similar to the expected values for other reference instruments (0.002-0.009). We have also found u(sup D)(sub AOD) values similar to the values reported in sun photometry for field instruments (approximately 0.015). In the case of the night-time period, the CE318-T-estimated standard combined uncertainty (u(sup N)(sub AOD)) is dependent not only on the calibration technique but also on illumination conditions and the instrumental noise. These values range from 0.011-0.018 for Lunar Langley-calibrated instruments to 0.012-0.021 for instruments calibrated using the Sun Ratio technique. In the case of moon-calibrated instruments using the Sun-Moon gain factor method and sun calibrated using the Langley technique, we found u(sup N)(sub AOD) ranging from 0.016 to 0.017 (up to 0.019 in 440 nm channel), not dependent on any lunar irradiance model. A subsequent performance evaluation including CE318-T and collocated measurements from independent reference instruments has served to assess the CE318-T performance as well as to confirm its estimated uncertainty. Daytime AOD evaluation, performed at Izana station from March to June 2014, encompassed measurements from a reference CE318-T, a CE318-AERONET master instrument, a Precision Filter Radiometer (PFR) and a Precision Spectroradiometer (PSR) prototype, reporting low AOD discrepancies between the four instruments (up to 0.006). The nocturnal AOD evaluation was performed using CE318-T- and starphotometer-collocated measurements and also by means of a day/night coherence transition test using the CE318-T master instrument and the CE318 daytime data from the CE318-AERONET master instrument. Results showed low discrepancies with the star photometer at 870 and 500 nm channels(less tna or equal to 0.013) and differences with AERONET daytime data (1 h after and before sunset and sunrise) in agreement with the estimated u(sup N)(sub AOD) values at all illumination conditions in the case of channels within the visible spectral range, and only for high moon's illumination conditions in the case of near infrared channels. Perceptible water vapour (PWV) validation showed a good agreement between CE318-T and Global Navigation Satellite System (GNSS) PWV values for all illumination conditions, within the expected precision for sun photometry. Finally, two case studies have been included to highlight the ability of the new CE318-T to capture the diurnal cycle of aerosols and water vapour as well as short-term atmospheric variations, critical for climate studies.

Barreto, Africa↗

Detecting Proxima b’s Atmosphere with JWST Targeting CO{sub 2} at 15 μ m Using a High-pass Spectral Filtering Technique

Exoplanet Proxima b will be an important laboratory for the search for extraterrestrial life for the decades ahead. Here, we discuss the prospects of detecting carbon dioxide at 15 μ m using a spectral filtering technique with the Medium Resolution Spectrograph (MRS) mode of the Mid-Infrared Instrument (MIRI) on the James Webb Space Telescope ( JWST ). At superior conjunction, the planet is expected to show a contrast of up to 100 ppm with respect to the star. At a spectral resolving power of R = 1790–2640, about 100 spectral CO{sub 2} features are visible within the 13.2–15.8 μ m (3B) band, which can be combined to boost the planet atmospheric signal by a factor of 3–4, depending on the atmospheric temperature structure and CO{sub 2} abundance. If atmospheric conditions are favorable (assuming an Earth-like atmosphere), with this new application to the cross-correlation technique, carbon dioxide can be detected within a few days of JWST observations. However, this can only be achieved if both the instrumental spectral response and the stellar spectrum can be determined to a relative precision of ≤1 × 10{sup −4} between adjacent spectral channels. Absolute flux calibration is not required, and the method is insensitive to the strong broadband variability of the host star. Precise calibration of the spectral features of the host star may only be attainable by obtaining deep observations of the system during inferior conjunction that serve as a reference. The high-pass filter spectroscopic technique with the MIRI MRS can be tested on warm Jupiters, Neptunes, and super-Earths with significantly higher planet/star contrast ratios than the Proxima system.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and Operation of a Material Identification and Discrimination Imaging Spectroradiometer

Many imaging applications require quantitative determination of a scene's spectral radiance. This paper describes a new system capable of real-time spectroradiometric imagery. Operating at a full-spectrum update rate of 30Hz, this imager is capable of collecting a 30 point spectrum from each of three imaging heads: the first operates from 400 nm to 950 nm, with a 2% bandwidth; the second operates from 1.5 micro-m to 5.5 micro-m with a 1.5% bandwidth; the third operates from 5 micro-m to 12 micro-m, also at a 1.5% bandwidth. Standard image format is 256 x 256, with 512 x 512 possible in the VIS/NIR head. Spectra of up to 256 points are available at proportionately lower frame rates. In order to make such a tremendous amount of data more manageable, internal processing electronics perform four important operations on the spectral imagery data in real-time. First, all data in the spatial/spectral cube of data is spectro-radiometrically calibrated as it is collected. Second, to allow the imager to simulate sensors with arbitrary spectral response, any set of three spectral response functions may be loaded into the imager including delta functions to allow single wavelength viewing; the instrument then evaluates the integral of the product of the scene spectral radiances and the response function. Third, more powerful exploitation of the gathered spectral radiances can be effected by application of various spectral-matched filtering algorithms to identify pixels whose relative spectral radiance distribution matches a sought-after spectral radiance distribution, allowing materials-based identification and discrimination. Fourth, the instrument allows determination of spectral reflectance, surface temperature, and spectral emissivity, also in real-time. The spectral imaging technique used in the instrument allows tailoring of the frame rate and/or the spectral bandwidth to suit the scene radiance levels, i.e., frame rate can be reduced, or bandwidth increased to improve SNR when viewing low radiance scenes. The unique challenges of design and calibration are described. Pixel readout rates of 160 MHz, for full frame readout rates of 1000 Hz (512 x 512 image) present the first challenge; processing rates of nearly 600 million integer operations per second for sensor emulation, or over 2 billion per second for matched filtering, present the second. Spatial and spectral calibration of 66,536 pixels (262,144 for the 512 x 512 version) and up to 1,000 spectral positions mandate novel decoupling methods to keep the required calibration memory to a reasonable size. Large radiometric dynamic range also requires care to maintain precision operation with minimum memory size.

Dombrowski, Mark↗

The track-length extension fitting algorithm for energy measurement of interacting particles in liquid argon TPCs and its performance with ProtoDUNE-SP data

This paper introduces a novel track-length extension fitting algorithm for measuring the kinetic energies of inelastically interacting particles in liquid argon time projection chambers (LArTPCs). The algorithm finds the most probable offset in track length for a track-like object by comparing the measured ionization density as a function of position with a theoretical prediction of the energy loss as a function of the energy, including models of electron recombination and detector response. The algorithm can be used to measure the energies of particles that interact before they stop, such as charged pions that are absorbed by argon nuclei. The algorithm's energy measurement resolutions and fractional biases are presented as functions of particle kinetic energy and number of track hits using samples of stopping secondary charged pions in data collected by the ProtoDUNE-SP detector, and also in a detailed simulation. Additional studies describe the impact of the dE/dx model on energy measurement performance. The method described in this paper to characterize the energy measurement performance can be repeated in any LArTPC experiment using stopping secondary charged pions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of cartridge filters from the IEA-R1 Nuclear Reactor

The management of radioactive waste ensures safety to human health and the environment nowadays and for the future, without overwhelming the upcoming generations. The primary characterization of radioactive waste is one of the main steps in the management of radioactive waste. This step permits to choose the best treatment for the radioactive waste before forwarding it to its final disposal. The aim of the present work is the primary characterization of cartridge filters from the IEA-R1 nuclear reactor utilizing gamma-ray spectrometry, and the method of Monte Carlo for calibration. The IEA-R1 is located in the Nuclear and Energy Research Institute (IPEN - CNEN) in the city of Sao Paulo, Brazil. Cartridge filters are used for purification of the cooling water that is pumped through the core of the pool type nuclear research reactors. Once worn out, these filters are replaced and then become radioactive waste. Determination of the radioactive inventory is of paramount importance in the management of such radioactive waste, and one of the main methods for doing so is the gamma-ray spectrometry, which can identify and quantify high energy photon emitters. The technique chosen for the characterization of radioactive waste in the present work is the gamma-ray spectrometry with High purity Germanium (HPGe) detectors. From the energy identified in the experimental spectrum, three radioisotopes were identified in the cartridge filter: {sup 108m}Ag, {sup 110m}Ag, {sup 60}Co. For the estimated activity of the filter, the calibration in efficiency was made utilizing the MCNP4C code of the Monte Carlo method. Such method was chosen because there is no standard source available in the same geometry of the cartridge filter, therefore a simulation had to be developed in order to reach a calibration equation, necessary to estimate the activity of the radioactive waste. The results presented an activity value in the order of MBq for all radioisotopes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

INVESTIGATION OF HUMAN RELIABILITY ANALYSIS METHODS FOR ANALYZING PRE-INITIATORS

As a type of human actions defined in human reliability analysis (HRA), pre-initiator refers to the human actions that may lead to the unavailability of systems, typically committed during maintenance, test, or calibration. This paper investigates representative HRA methods used for analyzing pre-initiators. The HRA methods are Technique for Human Error Rate Prediction (THERP), Korean Standard HRA (K-HRA) and Standard Plant Risk HRA (SPAR-H). In this paper, characteristics of each HRA method are compared for qualitative and quantification aspects. Two pre-initiators, i.e., a calibration task and a valve restoration task, are analyzed using the HRA methods to compare human error probabilities. Then, insights from the analysis and additional research requirements are discussed in this paper.

99 GENERAL AND MISCELLANEOUS↗

INVESTIGATION OF HUMAN RELIABILITY ANALYSIS METHODS FOR ANALYZING PRE-INITIATORS

As a type of human actions defined in human reliability analysis (HRA), pre-initiator refers to the human actions that may lead to the unavailability of systems, typically committed during maintenance, test, or calibration. This paper investigates representative HRA methods used for analyzing pre-initiators. The HRA methods are Technique for Human Error Rate Prediction (THERP), Korean Standard HRA (K-HRA) and Standard Plant Risk HRA (SPAR-H). In this paper, characteristics of each HRA method are compared for qualitative and quantification aspects. Two pre-initiators, i.e., a calibration task and a valve restoration task, are analyzed using the HRA methods to compare human error probabilities. Then, insights from the analysis and additional research requirements are discussed in this paper.

99 GENERAL AND MISCELLANEOUS↗

Towards Robust Calibration of the AWSD Reactive Burn Model

Calibration of a reactive burn model for detonation of high explosive is an important step towards predictive hy drodynamic simulations of detonation. A typical calibration consists of varying model parameters (e.g., rate constants, activation energies) until results of hydrodynamic simulations match the experimental data for a certain set of ex periments. Hydrodynamic simulations of the dependence of steady detonation velocity on the radius of a cylindrical high-explosive charge - often used in such calibrations - can be computationally expensive. In this work, we propose a method where such expensive simulations are performed infrequently, and only to parameterize and refine a surrogate model for the dependence of the detonation velocity on calibrated parameters. The method is developed, implemented and applied to an example problem - calibration of the AWSD reactive burn model for important high explosive PBX 9502. Two different flavors of the surrogate model are investigated, and the calibration is performed successfully.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precise and direct method for the measurement of the torsion spring constant of the atomic force microscopy cantilevers

A direct method for the evaluation of the torsional spring constants of the atomic force microscope cantilevers is presented in this paper. The method uses a nanoindenter to apply forces at the long axis of the cantilever and in the certain distance from it. The torque vs torsion relation is then evaluated by the comparison of the results of the indentations experiments at different positions on the cantilever. Next, this relation is used for the precise determination of the torsional spring constant of the cantilever. The statistical analysis shows that the standard deviation of the calibration measurements is equal to approximately 1%. Furthermore, a simple method for calibration of the photodetector’s lateral response is proposed. The overall procedure of the lateral calibration constant determination has the accuracy approximately equal to 10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Waste Characterization Using Gamma Ray Spectrometry with Automated Efficiency Optimization - 13404

Gamma ray spectrometry using High Purity Germanium (HPGe) detectors is commonly employed in assaying radioactive waste streams from a variety of sources: nuclear power plants, Department of Energy (DOE) laboratories, medical facilities, decontamination and decommissioning activities etc. The radioactive material is typically packaged in boxes or drums (for e.g. B-25 boxes or 208 liter drums) and assayed to identify and quantify radionuclides. Depending on the origin of the waste stream, the radionuclides could be special nuclear materials (SNM), fission products, or activation products. Efficiency calibration of the measurement geometry is a critical step in the achieving accurate quantification of radionuclide content. Due to the large size of the waste items, it is impractical and expensive to manufacture gamma ray standard sources for performing a measurement based calibration. For well over a decade, mathematical efficiency methods such as those in Canberra's In Situ Object Counting System (ISOCS) have been successfully employed in the efficiency calibration of gamma based waste assay systems. In the traditional ISOCS based calibrations, the user provides input data such as the dimensions of the waste item, the average density and fill height of the matrix, and matrix composition. As in measurement based calibrations, the user typically defines a homogeneous matrix with a uniform distribution of radioactivity. Actual waste containers can be quite nonuniform, however. Such simplifying assumptions in the efficiency calibration could lead to a large Total Measurement Uncertainty (TMU), thus limiting the amount of waste that can be disposed of as intermediate or low activity level waste. To improve the accuracy of radionuclide quantification, and reduce the TMU, Canberra has developed the capability to optimize the efficiency calibration using the ISOCS method. The optimization is based on benchmarking the efficiency shape and magnitude to the data available in the analyzed gamma ray spectra. Data from measurements of a given item in multiple counting geometries are among the powerful benchmarks that could be used in the optimization. Also, while assaying a waste stream with fission products and activation products emitting gamma lines of multiple energies, optimizing the efficiency on the basis of line activity consistency is very effective. In the present paper, the ISOCS- based optimization methodology is applied to measurement scenarios involving multiple counting geometries, and multi-gamma-line radionuclides. Results will be presented along with accuracy and precision estimates for each measurement. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Further investigation into calibration techniques for a magnetic suspension and balance system

Calibrations performed on three different magnetic cores for wind tunnel models suspended in the Southampton University Magnetic Suspension and Balance System (SUMSBS) are detailed. The first core investigated was the Southampton University pilot Superconducting Solenoid model, first flown in July 1983. Static calibrations of lift force, drag force and pitching moment, together with lift force and pitching moment calibrations determined by the dynamic method are detailed in this report. Other types of core investigated in a similar manner were conventional permanent magnets, Alnico and samarium-cobalt. All static calibrations gave a linear dependence of force on electromagnet current as expected. Dynamic calibrations are faster to perform but are proving to be not as easily analyzed as static calibrations. There are still some effects to be explained but dynamic lift calibration results were obtained agreeing to within 2 percent of the static calibration value.

Eskins, J.↗

On-Orbit Calibration of Redundant Spacecraft Gyros by Optimal Reduction to Three Axes

The Aqua spacecraft will carry four single-axis gyros configured with three orthogonal axes and one skew axis. This redundancy presents a challenge for batch methods of on-orbit gyro calibration that use a spacecraft rotation model deterministically related to gyro data, in that sensor data can respond to at most three angular velocity components. When the number of gyros, N, is greater than 3, the 3xN matrix, G, that reduces the N gyro measurements to three body-frame angular-velocity components cannot be fully determined by such methods; there are many such matrices that produce essentially the same angular velocity history. In such a case, spacecraft operators require information about the Nx3 gyro linear response matrix, R, that relates gyro outputs to the body-frame angular velocities causing them. This matrix provides sufficient information to determine multiple reduced-dimension G-matrices for use in case of failure or degradation of one or more gyros, as well as to determine an optimal 3xN G for the fully-functional configuration. A viable proposal is to apply a 3xN pre-filter matrix, F, to the N gyro outputs before carrying out a conventional gyro calibration procedure. The angular-velocity history emerging from conventional calibration may then be used as input data, together with the same gyro data that generated it, to fit the alignment, scale-factor, and bias parameters of each gyro axis in turn. A difficulty of such a proposal is the arbitrariness in the choice of F. Due to gyro noise, different pre-filter matrices produce different calibrations. This paper presents a method of choosing F that is based on optimizing gyro consistency in the limit of infinite weight on gyro data, as compared to sensor data. The choice of F is independent of a priori alignment and is based on the gyro data alone. The method is applicable to any N of three or more, but reduces to conventional batch-estimation methodologies when N = 3. Results of computational comparison among calibration simulations using various choices of F will be presented for the Aqua gyro configuration with N = 4.

Radomski, M. S.↗

Informing solar blind radioluminescence imaging through a calibrated spectrum

While direct radiation detection methods offer great insight into the origin of ionizing particles and photons, their use to locate contaminated areas or concealed radioactive sources can lead to undue exposure of personnel and equipment to ionizing radiation or the potential for contamination. These same sources induce ultraviolet (UV) optical photon fluorescence in air – a process referred to as radioluminescence – that may be imaged from low dose regions over larger attenuation lengths than ionizing radiation. However, most optical detection methods are limited to low lighting conditions to image the more abundant ultraviolet-A (UV-A) photons. To extend this capability to room light or daytime conditions, the solar blind region (Ultraviolet-C (UV-C), <280 nm) can be tapped. Though the emission yield of UV-C photons is roughly two orders of magnitude lower than that in the UV-A regime, the UV-C offers dramatic improvements in signal-to-noise ratios under bright lighting conditions due to decreased background interferences. The yield of specific UV-C lines, if present in the literature at all, varies widely, which has a large impact in modeling and analyzing standoff UV-C measurement scenarios. Thus, we have captured improved radioluminescence spectra over 250–400 nm and identified observed emission peaks in ambient air. Many of the UV-C photons produced by ionizing radiation excitation result from high-energy, molecular nitrogen Gaydon-Herman transitions which have had limited study to date for this application. Relating these findings to published UV-A yields, we estimate emissions between 0.15–0.19 photons/MeV over 250–280 nm. Additionally, we also use a commercial corona-discharge imaging camera to demonstrate outdoor UV-C radiation mapping of alpha and gamma emitters from 50 and 75 m standoffs, respectively. The imaged “counts” are compared to optically modelled values and show the same trend over distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reducing model bias in a deep learning classifier using domain adversarial neural networks in the MINERvA experiment

We present a simulation-based study using deep convolutional neural networks (DCNNs) to identify neutrino interaction vertices in the MINERvA passive targets region, and illustrate the application of domain adversarial neural networks (DANNs) in this context. DANNs are designed to be trained in one domain (simulated data) but tested in a second domain (physics data) and utilize unlabeled data from the second domain so that during training only features which are unable to discriminate between the domains are promoted. MINERvA is a neutrino-nucleus scattering experiment using the NuMI beamline at Fermilab. A-dependent cross sections are an important part of the physics program, and these measurements require vertex finding in complicated events. To illustrate the impact of the DANN we used a modified set of simulation in place of physics data during the training of the DANN and then used the label of the modified simulation during the evaluation of the DANN. In conclusion, we find that deep learning based methods offer significant advantages over our prior track-based reconstruction for the task of vertex finding, and that DANNs are able to improve the performance of deep networks by leveraging available unlabeled data and by mitigating network performance degradation rooted in biases in the physics models used for training.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS): Inflight radiometric calibration and the determination of surface reflectance

The inflight radiometric performance of AVIRIS is presented together with a comparison of methods of recovering surface spectral reflectance from the data. Performance is evaluated by comparing radiance predicted from AVIRIS with radiance generated from the LOWIRAN 6 atmospheric model and measured surface reflectance. Comparisons show apparent agreement to within a few percent between 1800 and 2450 nm. Between 600 and 1800 nm the response of AVIRIS is systematically low by as much as 70 percent, and between 400 and 600 nm it is higher than expected. These problems are traced to thermal distortions of the instrument, and to detachment during flight of optical fibers connecting foreoptics to two of four spectrometers in the instrument. Of three methods studied, an empirical one involving calibration curves constructed from field reflectance measurements returns accurate predictions of the surface reflectance independent of the actual radiometric significance of the flight data.

Conel, J. E.↗

In-situ relative calibration of Bragg crystals with Monte Carlo line ratio analysis

X-ray line emission spectra can thoroughly characterize hot plasmas, especially when line shapes and ratios convey distinct aspects of plasma conditions. However, the high spectral resolution required for observing line shapes is often at odds with the large bandwidth required to observe many line ratios across a wide spectral range. One strategy to obtain high spectral resolution over a wide bandwidth is to use multiple crystals with calibrated reflectivity so that line intensities across different crystals can be compared. Here, we explore the use of a low-resolution, wide-bandwidth mica survey spectrometer to infer relative reflectivity of two high-resolution, narrow-bandwidth quartz crystals. Finally, a Monte Carlo error analysis determines comparable x-ray line ratios measured from both spectrometers, resulting in an in situ calibration factor and associated uncertainty for the relative reflectivity of the high-resolution crystals.

47 OTHER INSTRUMENTATION↗

Two-dimensional plasma density evolution local to the inversion layer during sawtooth crash events using Beam Emission Spectroscopy

Here, we present methods for analyzing Beam Emission Spectroscopy (BES) data to obtain the plasma density evolution associated with rapid sawtooth crash events at the DIII-D tokamak. BES allows coverage over a 2D spatial plane, inherently local measurements, with fast time responses, and, therefore, provides a valuable new channel for data during sawtooth events. A method is developed to remove sawtooth-induced edge-light pulses contained in the BES data. The edge light pulses appear to be from the D α emission produced by edge recycling during sawtooth events, and are large enough that traditional spectroscopic filtering and data analysis techniques are insufficient to deduce physically meaningful quantities. A cross-calibration of 64 BES channels is performed by using a novel method to ensure accurate measurements. For the large-amplitude density oscillations observed, we discuss and use the non-linear relationship between the BES signal δI/ I 0 and the plasma density variation δn e / n e0 . The 2D BES images cover an 8 × 20 cm 2 region around the sawtooth inversion layer and show large-amplitude density oscillations, with additional significant spatial variations across the inversion layer that grows and peaks near the time of the temperature crash. The edge light removal technique and method of converting large-amplitude δI/ I 0 to δn e / n e0 presented here may help analyze other impulsive MHD phenomena in tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral Transfer Learning Using Information Geometry for a User-Independent Brain-Computer Interface

Recent advances in signal processing and machine learning techniques have enabled the application of Brain-Computer Interface (BCI) technologies to fields such as medicine, industry, and recreation; however, BCIs still suffer from the requirement of frequent calibration sessions due to the intra- and inter-individual variability of brain-signals, which makes calibration suppression through transfer learning an area of increasing interest for the development of practical BCI systems. In this paper, we present an unsupervised transfer method (spectral transfer using information geometry,STIG),which ranks and combines unlabeled predictions from an ensemble of information geometry classifiers built on data from individual training subjects. The STIG method is validated in both off-line and real-time feedback analysis during a rapid serial visual presentation task (RSVP). For detection of single-trial, event-related potentials (ERPs), the proposed method can significantly outperform existing calibration-free techniques as well as out perform traditional within-subject calibration techniques when limited data is available. Here, this method demonstrates that unsupervised transfer learning for single-trial detection in ERP-based BCIs can be achieved without the requirement of costly training data, representing a step-forward in the overall goal of achieving a practical user-independent BCI system.

60 APPLIED LIFE SCIENCES↗