Search NASA⌕ Search

SEARCH · Search NASA

Results for “DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Flow and Turbulence Control in a Boundary Layer Wind Tunnel Using Passive Hardware Devices

The Climatic Wind Tunnel (CWT) is a new experimental facility of the Institute of Theoretical and Applied Mechanics (ITAM) in Prague, Czech Republic. It is uniquely able to replicate precipitation and freezing effects on structural models in the climatic test section, and simultaneously perform aerodynamic and aeroelastic tests on structural models in the aerodynamic test section. Extensive measurements are carried out to investigate airflow and turbulence characteristics in the empty aerodynamic test section. Capability to experimentally simulate the atmospheric boundary layer (ABL) is studied using castellated barrier wall, Counihan vortex generators, and surface roughness elements. An individual influence of each of these passive hardware devices is separately tested as well, as they are commonly used combined, and their individual contributions to the ABL model characteristics are not well known. The analysis is based on hot-wire anemometer measurements carried out at various cross sections in the aerodynamic test section of the CWT. Experimental results are reported as mean velocity and turbulence intensity fields for the empty aerodynamic test section without passive hardware devices. Vertical profiles of mean velocity, turbulence intensity, and turbulence length scales, as well as power spectral density of velocity fluctuations, are reported for the ABL small-scale model. The barrier is observed to cause a decrease in flow velocity and an increase in turbulence close to surface. Vortex generators enhance turbulence throughout the entire height range under scope. Increased turbulence and decreased flow velocity are particularly exhibited close to surface due to surface roughness. Influence of each of the studied passive hardware devices on flow and turbulence is quantified in a dimensionless form to allow for separately accounting for their effects.

42 ENGINEERING↗

Interpenetrated Structures for Enhancing Ion Diffusion Kinetics in Electrochemical Energy Storage Devices

The architectural design of electrodes offers new opportunities for next-generation electrochemical energy storage devices (EESDs) by increasing surface area, thickness, and active materials mass loading while maintaining good ion diffusion through optimized electrode tortuosity. However, conventional thick electrodes increase ion diffusion length and cause larger ion concentration gradients, limiting reaction kinetics. We demonstrate a strategy for building interpenetrated structures that shortens ion diffusion length and reduces ion concentration inhomogeneity. This free-standing device structure also avoids short-circuiting without needing a separator. The feature size and number of interpenetrated units can be adjusted during printing to balance surface area and ion diffusion. Starting with a 3D-printed interpenetrated polymer substrate, we metallize it to make it conductive. This substrate has two individually addressable electrodes, allowing selective electrodeposition of energy storage materials. Using a Zn//MnO 2 battery as a model system, the interpenetrated device outperforms conventional separate electrode configurations, improving volumetric energy density by 221% and exhibiting a higher capacity retention rate of 49% compared to 35% at temperatures from 20 to 0 °C. Our study introduces a new EESD architecture applicable to Li-ion, Na-ion batteries, supercapacitors, etc.

25 ENERGY STORAGE↗

High power beta electron device - Beyond betavoltaics

Developing watt level power sources with beta emitting radioisotopes has been limited by the inability to utilize high energy (> 100 KeV) beta emitters at high radioisotope loadings without damaging the energy conversion materials. A new type of beta electron power source is described that removes those restrictions. This approach contains the radioisotope in a beta transparent titanium tube and confines beta electrons emitted through the tube wall to spiral trajectories around the tube with an axial magnetic field. The confined beta electrons dissipate energy though multiple interactions with surrounding excimer precursor gas atoms to efficiently generate photons. Photovoltaic cells convert the photons to electrical power. Since the beta electrons dissipate energy in the excimer precursor gas, the device can be loaded with more than 10 13 Bq of radioisotope to generate 100 milliwatt to watt levels of electrical power without damaging the device materials or degrading its performance. Furthermore, the power source can use a variety of beta radioisotopes and scales by stacking the devices.

30 DIRECT ENERGY CONVERSION↗

Effect of rapid thermal annealing of copper indium aluminium gallium diselenide solar cell devices and its deposition challenges

Thin-film photovoltaic research based on ternary or quaternary absorber materials has mainly concentrated on copper (indium/gallium) diselenide, CuIn x Ga 1-x Se 2 (CIGS). This material has demonstrated exceptional energy conversion efficiencies. By altering the In/Ga ratio the band gap can be varied from 1.02 eV (for CuInSe 2 ) to 1.68 eV (for CuGaSe 2 ). However, research from leading groups showed that cells have maximum efficiency at or below 1.35 eV. This paper reports the challenges of using aluminium alloyed CIGS deposited with a single step co-evaporation method. Adding aluminium is found to reduce the bulk trap state density for wide gap devices. However, it created significant safety issues when compared to conventional CIGS co-evaporation deposition systems. The release of H 2 Se when moisture comes in contact with aluminium selenide was resolved by placing exhaust lines at various places of the deposition chamber. A single phase CIAGS device with a bandgap of 1.30 eV was prepared using a co-evaporation method. The fabricated solar cell devices with CIAGS absorber layers and resulted in a photoconversion efficiency of 10.3%. A progressive rapid thermal annealing at various temperature resulted in a 10% increase in the overall efficiency at 300 °C. The efficiencies were reduced when the RTA temperature increased above 300 °C.

14 SOLAR ENERGY↗

SIMS and HR-XPS characterization of lithiated graphite from the magnetic fusion device RFX-mod

Lithium wall conditioning has improved the performance of many magnetic fusion devices. Li conditioning in the RFX-mod device was performed by: (1) a single Li pellet injector and (2) a multi-Li pellet injector during He plasma discharges; (3) a Li evaporator after He glow discharge cleaning and He plasma discharge exposure. This report compares the spatial and depth distributions of Li deposited on polycrystalline graphite witness samples at different locations in RFX-mod and the elemental and chemical compositions of the resulting surfaces. The sample surfaces were analyzed ex situ using secondary ion mass spectrometry (SIMS) and high-resolution X-ray photoelectron spectroscopy (HR-XPS). The results showed that Li pellet injection provided a relatively uniform toroidal coverage while Li evaporation produced highly localized Li deposition. A Li 1s HR-XPS peak at 56.5 eV binding energy (BE) characteristic of lithium-intercalated graphite was only observed with the sample exposed to Li evaporation. All of the samples exhibited a HR-XPS C 1s peak at 285.1–285.2 eV BE that is largely attributed to hydrogenated graphite. This finding suggests that hydrogenation of fresh graphite occurs during He plasma discharge exposures. Finally, our results have implications for density control and the selection of Li conditioning techniques in magnetic fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Fe3O4@TiO2 Nanoparticles-based Test Strip Immunosensing Device for Rapid Detection of Phosphorylated Butyrylcholinesterase

An integrated magnetic nanoparticles-based test-strip immunosensing device was developed for rapid and sensitive quantification of phosphorylated butyrylcholinesterase (BChE), the biomarker of exposure to organophosphous pesticides (OP), in human plasma. In order to overcome the difficulty in scarce availability of OP-specific antibody, here magnetic Fe3O4@TiO2 nanoparticles were used and adsorbed on the test strip through a small magnet inserted in the device to capture target OP-BChE through selective binding between TiO2 and OP moiety. Further recognition was completed by horseradish peroxidase (HRP) and anti-BChE antibody (Ab) co-immobilized gold nanoparticles (GNPs). Their strong affinities among Fe3O4@TiO2, OP-BChE and HRP/Ab-GNPs were characterized by quartz crystal microbalance (QCM), surface plasmon resonance (SPR) and square wave voltammetry (SWV) measurements. After cutting off from test strip, the resulted immunocomplex (HRP/Ab-GNPs/OP-BChE/Fe3O4@TiO2) was measured by SWV using a screen printed electrode under the test zone. Greatly enhanced sensitivity was achieved by introduction of GNPs to link enzyme and antibody at high ratio, which amplifies electrocatalytic signal significantly. Moreover, the use of test strip for fast immunoreactions reduces analytical time remarkably. Coupling with a portable electrochemical detector, the integrated device with advanced nanotechnology displays great promise for sensitive, rapid and in-filed on-site evaluation of OP poisoning.

biomarkers↗

Spatial influence of paramagnetic molecules on magnetic tunnel junction-based molecular spintronic devices (MTJMSD)

Magnetic Tunnel Junction-Based Molecular Spintronic Devices (MTJMSDs) are potential candidates for inventing highly correlated systems. Understanding MTJMSD's magnetic behavior is essential to designing and fabricating practical devices. This paper investigates the effect of two contributing factors on MTJMSD's magnetic properties via Monte Carlo Simulation. Here, we have systematically studied coupling strengths and nature between magnetic molecules and ferromagnetic electrodes at various temperatures. We have also investigated the effect of length and thickness increase on MTJMSD temporal and spatial evolution of magnetic moment, magnetic correlation, and magnetic susceptibility. Our results showed that thermal energy increase significantly affects molecular devices.

74 ATOMIC AND MOLECULAR PHYSICS↗

Perfectly Matched Layers versus discrete transparent boundary conditions in quantum device simulations

Discrete transparent boundary conditions (DTBC) and the Perfectly Matched Layers (PML) method for the realization of open boundary conditions in quantum device simulations are compared, based on the stationary and time-dependent Schrödinger equation. The comparison includes scattering state, wave packet, and transient scattering state simulations in one and two space dimensions. The Schrödinger equation is discretized by a second-order Crank–Nicolson method in case of DTBC. For the discretization with PML, symmetric second-, fourth-, and sixth-order spatial approximations as well as Crank–Nicolson and classical Runge–Kutta time-integration methods are employed. In two space dimensions, a ring-shaped quantum waveguide device is simulated in the stationary and transient regime. As an application, a simulation of the Aharonov–Bohm effect in this device is performed, showing the excitation of bound states localized in the ring region. The numerical experiments show that the results obtained from PML are comparable to those obtained using DTBC, while keeping the high numerical efficiency and flexibility as well as the ease of implementation of the former method. -- Highlights: •In-depth comparison between discrete transparent boundary conditions (DTBC) and PML. •First 2-D transient scattering state simulations using DTBC. •First 2-D transient scattering state simulations of the Aharonov–Bohm effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient and scalable GaInAs thermophotovoltaic devices

We report thermophotovoltaics are promising solid-state energy converters for a variety of applications such as grid-scale energy storage, concentrating solar-thermal power, and waste-heat recovery. Here, we report the design, fabrication, and testing of large area (0.8 cm 2 ), scalable, single-junction 0.75-eV GaInAs thermophotovoltaic devices reaching an efficiency of 38.8% +/- 2.0% and an electrical power density of 3.78 W/cm 2 at an emitter temperature of 1,850 °C. Reaching such a high emitter temperature and power density without sacrificing efficiency is a direct result of combining good spectral management with an optimized cell architecture, excellent material quality, and low series resistance. Importantly, fabrication of 12 high-performing devices on a 2-in wafer is shown to be repeatable, and the cell design can be readily transferred to commercial epitaxy on even larger wafers. Further improvements in efficiency can be obtained by using a multijunction architecture, illustrated by early results for a two-junction 0.84-eV GaInPAs/0.75-eV GaInAs device.

14 SOLAR ENERGY↗

Green route synthesis of high quality CdSe quantum dots for applications in light emitting devices

Investigation was made on light emitting diodes fabricated using CdSe quantum dots. CdSe quantum dots were synthesized chemically using olive oil as the capping agent, instead of toxic phosphine. Room temperature photoluminescence investigation showed sharp 1st excitonic emission peak at 568 nm. Bi-layer organic/inorganic (P3HT/CdSe) hybrid light emitting devices were fabricated by solution process. The electroluminescence study showed low turn on voltage ({approx}2.2 V) .The EL peak intensity was found to increase by increasing the operating current. - Graphical abstract: Light emitting diode was fabricated using CdSe quantum dots using olive oil as the capping agent, instead of toxic phosphine. Bi-layer organic/inorganic (P3HT/CdSe) hybrid light emitting device shows strong electroluminescence in the range 630-661 nm. Highlights: Black-Right-Pointing-Pointer CdSe Quantum dots were synthesized using olive oil as the capping agent. Black-Right-Pointing-Pointer Light emitting device was fabricated using CdSe QDs/P3HT polymer heterojunction. Black-Right-Pointing-Pointer The I-V characteristics study showed low turn on voltage at {approx}2.2 V. Black-Right-Pointing-Pointer The EL peak intensity increases with increasing the operating current.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative SEM and TEM analyses of apatite phases prepared by a multi-sample loading device

Highlights: • A multi-sample loading device which ultrasonically disperses samples was developed. • Comparative EM analyses on various apatite phases were efficiently carried out. • SEM-EDS data revealed distinctive values of O/P and Ca/P intensity ratios. • TEM-SAED data presented characteristic structural features of apatite phases. • Lattice parameters of bone and fossil apatite were affected by CO{sub 3} content. - Abstract: Comparative chemical and structural characterization of various apatite phases from both synthetic and natural sources were carried out by utilizing a multi-sample loading device developed for scanning electron microscopy (SEM) and transmission electron microscopy (TEM) analyses. The device is capable of spraying nanoparticles via ultrasonication, and four separate samples were loaded on a single TEM grid by a masking tool to characterize different apatite phases in consistent instrumental and analytical conditions. SEM energy dispersive spectroscopy (EDS) analysis of the apatite samples revealed distinctive values of O/P and Ca/P intensity ratios except for the fossil apatite due to its high proportion of externally originating phases. Selected area electron diffraction (SAED) pattern analysis presented the characteristic lattice parameters of the apatite phases, especially the bone and fossil apatite which had CO{sub 3}in their chemistry. Analyzing distinctive chemical and structural features among varied apatite phases can be efficiently carried out through electron microscopy with multiple samples on a single TEM grid, and such methods can be employed for characterizing a wider range of materials.

36 MATERIALS SCIENCE↗

Thin-film TaAs: Developing a platform for Weyl semimetal devices

MX monopnictide compounds (M = Nb,Ta, X = As,P) are prototypical 3D Weyl semimetals (WSMs) that have been shown in bulk single crystal form to have potential for a wide variety of novel devices due to topologically protected band structures and high mobilities. However, very little is known about thin-film synthesis, which is essential to enable device applications. We synthesize TaAs(001) epilayers by molecular beam epitaxy on GaAs(001) and provide an experimental phase diagram illustrating conditions for single-phase, single-crystal-like growth. We investigate the relationship between nanoscale defects and electronic structure using angle-resolved photoemission spectroscopy, kelvin probe force microscopy, and transmission electron microscopy. Our results provide a roadmap and platform for developing 3D WSMs for device applications.

36 MATERIALS SCIENCE↗

Skin Dose Impact from Vacuum Immobilization Device and Carbon Fiber Couch in Intensity Modulated Radiation Therapy for Prostate Cancer

To investigate the unexpected skin dose increase from intensity-modulated radiation therapy (IMRT) on vacuum cushions and carbon-fiber couches and then to modify the dosimetric plan accordingly. Eleven prostate cancer patients undergoing IMRT were treated in prone position with a vacuum cushion. Two under-couch beams scattered the radiation from the vacuum cushion and carbon-fiber couch. The IMRT plans with both devices contoured were compared with the plans not contouring them. The skin doses were measured using thermoluminescent dosimeters (TLDs) placed on the inguinal regions in a single IMRT fraction. Tissue equivalent thickness was transformed for both devices with the relative densities. The TLD-measured skin doses (59.5 {+-} 9.5 cGy and 55.6 {+-} 5.9 cGy at left and right inguinal regions, respectively) were significantly higher than the calculated doses (28.7 {+-} 4.7 cGy; p = 2.2 x 10{sup -5} and 26.2 {+-} 4.3 cGy; p = 1.5 x 10{sup -5}) not contouring the vacuum cushion and carbon-fiber couch. The calculated skin doses with both devices contoured (59.1 {+-} 8.8 cGy and 55.5 {+-} 5.7 cGy) were similar to the TLD-measured doses. In addition, the calculated skin doses using the vacuum cushion and a converted thickness of the simulator couch were no different from the TLD-measured doses. The recalculated doses of rectum and bladder did not change significantly. The dose that covered 95% of target volume was less than the prescribed dose in 4 of 11 patients, and this problem was solved after re-optimization applying the corrected contours. The vacuum cushion and carbon-fiber couch contributed to increased skin doses. The tissue-equivalent-thickness method served as an effective way to correct the dose variations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Prospective intra-patient evaluation of a shoulder retraction device for radiotherapy in head and neck cancer

Irradiation of tumors in the larynx and pharynx is often technically challenging in patients with a short neck or high shoulders. Shoulder retraction devices can sometimes resolve this problem and allow irradiation via lateral beam directions. This study aimed to measure the proportion of patients who would benefit from such an approach and to quantify the magnitude of the benefit obtained. Twenty patients were studied. Simulator images were obtained before and after intervention. The additional exposure of the cervical spine was measured. Patient comfort and acceptability were assessed with a questionnaire. Improvement of exposure of the cervical spine was observed in 80% of patients. In 20%, there was either no difference or the position was worse. Shoulder retraction exposed a mean of 8.4-10.2 mm more of the cervical spine. Patients in general reported the device as comfortable. The use of a shoulder retraction device produced clinically significant improvements in exposure of the tissues of the cervical spine and neck and should be considered in patients being irradiated for tumors arising in the larynx or hypopharynx.

61 RADIATION PROTECTION AND DOSIMETRY↗

Residual position errors of lymph node surrogates in breast cancer adjuvant radiotherapy: Comparison of two arm fixation devices and the effect of arm position correction

Residual position errors of the lymph node (LN) surrogates and humeral head (HH) were determined for 2 different arm fixation devices in radiotherapy (RT) of breast cancer: a standard wrist-hold (WH) and a house-made rod-hold (RH). The effect of arm position correction (APC) based on setup images was also investigated. A total of 113 consecutive patients with early-stage breast cancer with LN irradiation were retrospectively analyzed (53 and 60 using the WH and RH, respectively). Residual position errors of the LN surrogates (Th1-2 and clavicle) and the HH were investigated to compare the 2 fixation devices. The position errors and setup margins were determined before and after the APC to investigate the efficacy of the APC in the treatment situation. A threshold of 5 mm was used for the residual errors of the clavicle and Th1-2 to perform the APC, and a threshold of 7 mm was used for the HH. The setup margins were calculated with the van Herk formula. Irradiated volumes of the HH were determined from RT treatment plans. With the WH and the RH, setup margins up to 8.1 and 6.7 mm should be used for the LN surrogates, and margins up to 4.6 and 3.6 mm should be used to spare the HH, respectively, without the APC. After the APC, the margins of the LN surrogates were equal to or less than 7.5/6.0 mm with the WH/RH, but margins up to 4.2/2.9 mm were required for the HH. The APC was needed at least once with both the devices for approximately 60% of the patients. With the RH, irradiated volume of the HH was approximately 2 times more than with the WH, without any dose constraints. Use of the RH together with the APC resulted in minimal residual position errors and setup margins for all the investigated bony landmarks. Based on the obtained results, we prefer the house-made RH. However, more attention should be given to minimize the irradiation of the HH with the RH than with the WH.

61 RADIATION PROTECTION AND DOSIMETRY↗

4D nano-tomography of electrochemical energy devices using lab-based X-ray imaging

Electrochemical energy devices offer a variety of alternate means for low-carbon, multi-scale energy conversion and storage. Reactions in these devices are supported by electrodes with characteristically complex microstructures. To meet the increasing capacity and lifetime demands across a range of applications, it is essential to understand microstructural evolutions at a cell and electrode level which are thought to be critical aspects influencing material and device lifetime and performance. X-ray computed tomography (CT) has become a highly employed method for non-destructive characterisation of such microstructures with high spatial resolution. However, sub-micron resolutions present significant challenges for sample preparation and handling particularly in 4D studies, (three spatial dimensions plus time). Here, microstructural information is collected from the same region of interest within two electrode materials: a solid oxide fuel cell and the positive electrode from a lithium-ion battery. Using a lab-based X-ray instrument, tomograms with sub-micron resolutions were obtained between thermal cycling. The intricate microstructural evolutions captured within these two materials provide model examples of 4D X-ray nano-CT capabilities in tracking challenging degradation mechanisms. Furthermore, this technique is valuable in the advancement of electrochemical research as well as broader applications for materials characterisation.

25 ENERGY STORAGE↗

Impact of nuclear reactor radiation on the performance of AlN/sapphire surface acoustic wave devices

The performance of an AlN/sapphire surface acoustic wave (SAW) delay line device was characterized in real time under irradiation inside a nuclear reactor. Both its resonant frequency and transmission efficiency were observed to respond to a change in reactor power. The response follows an exponentially saturating behavior after a step power increase, followed by an exponentially decaying recovery after reactor shutdown. A sensitivity analysis based on the governing electro-mechanical equations shows that the frequency shift can be attributed to the softening of sapphire’s elastic constants under neutron radiation. Additionally, a kinetic rate equation is adopted to interpret device response and describe its microstructural evolution. These results suggest that the AlN/sapphire SAW device remains functional under irradiation, is sensitive to neutron and gamma ray fluxes, and offers an opportunity for remote sensing and in-situ measurement of material properties when exposed to nuclear reactor environment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Plasma edge and plasma-wall interaction modelling: Lessons learned from metallic devices

Robust power exhaust schemes employing impurity seeding are needed for target operational scenarios in present day tokamak devices with metallic plasma-facing components (PFCs). For an electricity-producing fusion power plant at power density P sep /R > 15 MW/m divertor detachment is a requirement for heat load mitigation. 2D plasma edge transport codes like the SOLPS code as well as plasma-wall interaction (PWI) codes are key to disentangle relevant physical processes in power and particle exhaust. With increased quantitative credibility in such codes more realistic and physically sound estimates of the life-time expectations and performance of metallic PFCs can be accomplished for divertor conditions relevant for ITER and DEMO. An overview is given on the recent progress of plasma edge and PWI modelling activities for (carbon-free) metallic devices, that include results from JET with the ITER-like wall, ASDEX Upgrade and Alcator C-mod. It is observed that metallic devices offer an opportunity to progress the understanding of underlying plasma physics processes in the edge. The validation of models can be substantially improved by eliminating carbon from the experiment as well as from the numerical system with reduced degrees of freedom as no chemical sputtering from amorphous carbon layers and no carbon or hydro-carbon transport are present. With the absence of carbon as the primary plasma impurity and given the fact that the physics of the PWI at metallic walls is less complex it is possible to isolate the crucial plasma physics processes relevant for particle and power exhaust. Finally, for a reliable 2D dissipative plasma exhaust model these are: cross-field drifts, complete kinetic neutral physics, geometry effects (including main-chamber, divertor and sub-divertor structures), SOL transport reflecting also the non-diffusive nature of anomalous transport, as well as transport within the pedestal region in case of significant edge impurity radiation affecting pedestal pressure and hence P sep .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗