Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

First results from IRENI - Rapid diffraction-limited high resolution imaging across the mid-infrared bandwidth

First results from IRENI, a new beamline at the Synchrotron Radiation Center, demonstrate that synchrotron chemical imaging, which combines the characteristics of bright, stable, broadband synchrotron source with a multi-element detector, produces diffraction-limited images at all wavelengths simultaneously. A single cell of Micrasterias maintained in a flow cell has been measured, and results show high quality spectra and images demonstrating diffraction limited, and therefore wavelength-dependent, spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Energy Diffraction-Enhanced X-ray Imaging

In order to apply the diffraction-enhanced X-ray imaging (DEI) method for much wider variety of samples, we have developed the high-energy DEI system. The energy of X-ray was increased up to 70 keV to achieve high permeability for heavy elements. The diffraction of Si(440) was used to keep large field of view. Demonstrative observation of an electrical cable was performed using the X-ray emitted from the vertical wiggler. The obtained images visualized not only the core and ground wire made of copper but also the isolator and outer jacket made of polymer clearly. The comparison of images obtained by the DEI and the absorption-contrast imaging showed that the sensitivity of DEI is about 10 times higher than that of the absorption method for light elements, and 3 times for heavy elements.

07 ISOTOPE AND RADIATION SOURCES↗

X‐Ray Diffraction Pattern and Optical Properties Of Disperse Red‐1 Thin Films Deposited By Electric Field Assisted PVD Method

Disperse Red‐1 (DR1) films have been prepared by Electric field‐assisted Physical Vapor Deposition (E‐PVD) method at various external electric field strengths on the ITO substrate. The resulted films were characterized by X‐ray diffraction spectroscopy and the optical properties are investigated by Reflectometric and ATR measurements. The XRD data show growing diffraction peaks with increasing electric field corresponding to increasing number of molecules deposited with the head‐to‐tail stacking along the molecular chain. Further, the reflectometer data show a rising trend of the optical refractive index of the films produced with increasing electric field. This result is consistent with the frequency shift of SPR (Surface Plasmon Resonance) measured by ATR method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diffraction from HERA to the LHC

Following a 15 year programme of intensive research into diffractive electron-proton scattering at HERA, it is important to transfer the knowledge and experience gained into the LHC programme. This contribution raises some current issues in diffraction at the LHC and suggests ways in which they might be addressed using HERA results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new detector array for diffractive physics in ALICE at the LHC

We discuss some aspects of a new sub-detector for the ALICE experiment at the LHC. This detector would enhance the capabilities of ALICE to study several topics of diffractive as well as of photon induced physics. It consists of four stations of scintillator pads that would tag the diffractive gap more efficiently.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffractive and total pp cross sections at the LHC and beyond

Results on factorization breaking in soft and hard hadron-hadron collisions, photo-production and deep inelastic scattering exhibit a universal behavior in a renormalization model where diffraction is mediated by a saturated colorless exchange with vacuum quantum numbers. Using this model, diffractive and total cross sections are predicted for LHC energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of an x-ray diffraction camera used in magnetic fields up to 10 T

A high-field x-ray diffraction (HF-XRD) camera was developed to observe structural changes of magnetic materials in magnetic fields up to 10 T. The instrument mainly consists of a Debye-Scherrer-type camera with a diameter of 80.1 mm, a 10-T cryocooled superconducting magnet with a 100-mm room-temperature bore, an x-ray source, a power supply, and a chiller for the x-ray source. An x-ray detector (image plate) in the HF-XRD camera can be taken out and inserted into the magnet without changing the sample position. The performance of the instrument was tested by measuring the HF-XRD for silicon and ferromagnetic MnBi powders. A change of x-ray diffraction pattern was observed due to the magnetic orientation of MnBi, showing that the instrument is useful for studying field-induced orientation processes and structural properties of field-controlled materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space charge effects in ultrafast electron diffraction and imaging

Understanding space charge effects is central for the development of high-brightness ultrafast electron diffraction and microscopy techniques for imaging material transformation with atomic scale detail at the fs to ps timescales. We present methods and results for direct ultrafast photoelectron beam characterization employing a shadow projection imaging technique to investigate the generation of ultrafast, non-uniform, intense photoelectron pulses in a dc photo-gun geometry. Combined with N-particle simulations and an analytical Gaussian model, we elucidate three essential space-charge-led features: the pulse lengthening following a power-law scaling, the broadening of the initial energy distribution, and the virtual cathode threshold. The impacts of these space charge effects on the performance of the next generation high-brightness ultrafast electron diffraction and imaging systems are evaluated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Combined measurement of the inclusive diffractive cross section at HERA

A combination is presented of the inclusive diffractive cross section measurements made by the H1 and ZEUS Collaborations at HERA. The analysis uses diffractive deep inelastic scattering data selected with the Proton Spectrometer technique. Correlations of systematic uncertainties are taken into account by the combination method, resulting in improved precision.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of absolute diffraction efficiency of a variable line spaced grating using reflectivity beamline

First and second order diffraction efficiency of a variable line spacing grating of average 1200 lines/mm density is measured at the reflectivity beam line of Indus-1. This grating is blazed at 3.2 deg. and has a blaze wavelength of 10 nm. The measurement has been carried out in the spectral range of 4.5 nm to 80 nm at 3o grazing angle of incidence. The maximum diffraction efficiency of the first order at {approx}10 nm has been found to be {approx} 23% and for the second order it is {approx}13%.

43 PARTICLE ACCELERATORS↗

Contributions of the electronic spin and orbital current to the CoCl{sub 4}{sup 2-} magnetic field probed in polarised neutron diffraction experiments

Polarised neutron diffraction experiments conducted at 4.2 K on Cs{sub 3}CoCl{sub 5} crystals have been analysed by using a four-dimensional model Hilbert space made of ab initio n-electron wave functions of the CoCl{sub 4}{sup 2-} molecular ion. Two spin-orbit mixing coefficients and several configuration interaction coefficients have been optimized by fitting calculated magnetic structure factors to experimental ones, to obtain the best ensemble density operator that is representable in the model space. A goodness of fit, {chi}{sup 2}, less then 1 has been obtained for the first time for the two experimental data sets available. In the present article, the optimized density operators are used to calculate the magnetic field densities that are the genuine observables probed in neutron diffraction experiments. Density maps of such observables are presented for the first time and numerical details are provided. The respective contributions of spin density and orbital current to the magnetic field density are analyzed.

36 MATERIALS SCIENCE↗

X-ray diffraction assisted spectroscopy of Rydberg states

X-ray diffraction combined with conventional spectroscopy could provide a powerful means to characterize electronically excited atoms and molecules. We demonstrate theoretically how x-ray diffraction from laser excited atoms can be used to determine electronic structure, including angular momentum composition, principal quantum numbers, and channel populations. A theoretical formalism appropriate for highly excited atoms, and easily extended to molecules, is presented together with numerical results for Xe and H atoms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Active diffraction gratings: Development and tests

We present the realization and characterization of an active spherical diffraction grating with variable radius of curvature to be used in grazing-incidence monochromators. The device consists of a bimorph deformable mirror on the top of which a diffraction grating with laminar profile is realized by UV lithography. The experimental results show that the active grating can optimize the beam focalization of visible wavelengths through its rotation and focus accommodation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination and correction of distortions and systematic errors in low-energy electron diffraction

We developed and implemented an algorithm to determine and correct systematic distortions in low-energy electron diffraction (LEED) images. The procedure is in principle independent of the design of the apparatus (spherical or planar phosphorescent screen vs. channeltron detector) and is therefore applicable to all device variants, known as conventional LEED, micro-channel plate LEED, and spot profile analysis LEED. The essential prerequisite is a calibration image of a sample with a well-known structure and a suitably high number of diffraction spots, e.g., a Si(111)-7×7 reconstructed surface. The algorithm provides a formalism which can be used to rectify all further measurements generated with the same device. In detail, one needs to distinguish between radial and asymmetric distortion. Additionally, it is necessary to know the primary energy of the electrons precisely to derive accurate lattice constants. Often, there will be a deviation between the true kinetic energy and the value set in the LEED control. Here, we introduce a method to determine this energy error more accurately than in previous studies. Following the correction of the systematic errors, a relative accuracy of better than 1% can be achieved for the determination of the lattice parameters of unknown samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray photoelectron diffraction study of dopant effects in La{sub 0.7}X{sub 0.3}MnO{sub 3} (X = La, Sr, Ca, Ce) thin films

We present and discuss element-specific x-ray photoelectron diffraction (XPD) patterns of La, Mn, O and the dopant ions Ca, Sr and Ce of various La{sub 0.7}X{sub 0.3}MnO (LXMO) films grown epitaxially on SrTiO{sub 3}(001) substrates. The recorded XPD polar scans are explained in the framework of multiple-scattering cluster calculations, where in general a very good agreement between experimental and theoretical data has been found. Results for all thin films are compatible with a tetragonally distorted cubic perovskite structure with similar MnO{sub 6} network. Strong evidence for Mn-site termination was found in all thin films. Dopant locations on A-type sites were clearly confirmed for Sr in LSMO and Ca in LCMO films by means of XPD polar scans. The absence of surface-sensitive Ce3d diffraction features for Ce in LCeMO points to non-equivalent Ce sites and related near-surface disorder.

36 MATERIALS SCIENCE↗

Femtosecond diffraction dynamics of laser-induced periodic surface structures on fused silica

The formation of laser-induced periodic surface structures (LIPSS) on fused silica upon irradiation with linearly polarized fs-laser pulses (50 fs pulse duration, 800 nm center wavelength) is studied experimentally using a transillumination femtosecond time-resolved (0.1 ps-1 ns) pump-probe diffraction approach. This allows to reveal the generation dynamics of near-wavelength-sized LIPSS showing a transient diffraction at specific spatial frequencies even before a corresponding permanent surface relief was observed. The results confirm that the ultrafast energy deposition to the materials surface plays a key role and triggers subsequent physical mechanisms such as carrier scattering into self-trapped excitons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Benchmark oxygen-oxygen pair-distribution function of ambient water from x-ray diffraction measurements with a wide Q-range

Four recent x-ray diffraction measurements of ambient liquid water are reviewed here. Each of these measurements represents a significant development of the x-ray diffraction technique applied to the study of liquid water. Sources of uncertainty from statistical noise, Q-range, Compton scattering, and self-scattering are discussed. The oxygen-hydrogen contribution to the measured x-ray scattering pattern was subtracted using literature data to yield an experimental determination, with error bars, of the oxygen-oxygen pair-distribution function, g{sub OO}(r), which essentially describes the distribution of molecular centers. The extended Q-range and low statistical noise of these measurements has significantly reduced truncation effects and related errors in the g{sub OO}(r) functions obtained. From these measurements and error analysis, the position and height of the nearest neighbor maximum in g{sub OO}(r) were found to be 2.80(1) A and 2.57(5) respectively. Numerical data for the coherent differential x-ray scattering cross-section I{sub X}(Q), the oxygen-oxygen structure factor S{sub OO}(Q), and the derived g{sub OO}(r) are provided as benchmarks for calibrating force-fields for water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron diffraction using ultrafast electron bunches from a laser-wakefield accelerator at kHz repetition rate

We show that electron bunches in the 50-100 keV range can be produced from a laser wakefield accelerator using 10 mJ, 35 fs laser pulses operating at 0.5 kHz. It is shown that using a solenoid magnetic lens, the electron bunch distribution can be shaped. The resulting transverse and longitudinal coherence is suitable for producing diffraction images from a polycrystalline 10 nm aluminum foil. The high repetition rate, the stability of the electron source, and the fact that its uncorrelated bunch duration is below 100 fs make this approach promising for the development of sub-100 fs ultrafast electron diffraction experiments.

43 PARTICLE ACCELERATORS↗