Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffuse Scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Diffuse reflectance of the ocean - The theory of its augmentation by chlorophyll a fluorescence at 685 nm

The radiative transfer equation is modified to include the effect of fluorescent substances and solved in the quasi-single scattering approximation for a homogeneous ocean containing fluorescent particles with wavelength independent quantum efficiency and a Gaussian shaped emission line. The results are applied to the in vivo fluorescence of chlorophyll a (in phytoplankton) in the ocean to determine if the observed quantum efficiencies are large enough to explain the enhancement of the ocean's diffuse reflectance near 685 nm in chlorophyll rich waters without resorting to anomalous dispersion. The computations indicate that the required efficiencies are sufficiently low to account completely for the enhanced reflectance. The validity of the theory is further demonstrated by deriving values for the upwelling irradiance attenuation coefficient at 685 nm which are in close agreement with the observations.

Gordon, H. R.↗

X-ray reverberations and the giant X-ray bursts

It is shown that the shape and spectral evolution of the giant X-ray bursts from the source 3U 1820-30 can be explained by Compton scattering of a short, intense X-ray pulse in a cloud surrounding the source. Pulse shapes due to Thomson scattering of an X-ray burst in an electron cloud were calculated for the (1) optically thin case on the assumption of one scattering per photon, (2) intermediate case with optical depth of about unity, and (3) optically thick case where the process is regarded as diffusion of photons through a uniform sphere. For the intermediate case, the effects of the reverberation were determined explicitly by Monte Carlo calculation. For an optical depth of 3, square pulse duration of 2 sec, characteristic cloud radius of 70,000 km, characteristic cloud density of 4 times 10 to the 14th per cu cm, and temperature of 5-30 keV, the calculations give a reasonably accurate description of X-ray bursts from 3U 1820-30. The scattering model does not imply the existence of a supermassive, central black hole.

Canizares, C. R.↗

WE-H-206-00: Advances in Preclinical Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-01: Photoacoustic Tomography: Multiscale Imaging From Organelles to Patients by Ultrasonically Beating the Optical Diffusion Limit

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-02: Recent Advances in Multi-Modality Molecular Imaging of Small Animals

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-03: Promises and Challenges of Benchtop X-Ray Fluorescence CT (XFCT) for Quantitative in Vivo Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

Pileup per particle identification

We propose a new method for pileup mitigation by implementing “pileup per particle identification” (PUPPI). For each particle we first define a local shape α which probes the collinear versus soft diffuse structure in the neighborhood of the particle. The former is indicative of particles originating from the hard scatter and the latter of particles originating from pileup interactions. The distribution of α for charged pileup, assumed as a proxy for all pileup, is used on an event-by-event basis to calculate a weight for each particle. The weights describe the degree to which particles are pileup-like and are used to rescale their four-momenta, superseding the need for jet-based corrections. Furthermore, the algorithm flexibly allows combination with other, possibly experimental, probabilistic information associated with particles such as vertexing and timing performance. We demonstrate the algorithm improves over existing methods by looking at jet p T and jet mass. As a result, we also find an improvement on non-jet quantities like missing transverse energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamics of Hydration Water in Sugars and Peptides Solutions

We analyzed solute and solvent dynamics of sugars and peptides aqueous solutions using extended epolarized light scattering (EDLS) and broadband dielectric spectroscopies (BDS). Spectra measured with both techniques reveal the same mechanism of rotational diffusion of peptides molecules. In the case of sugars, this solute reorientational relaxation can be isolated by EDLS measurements, whereas its ontribution to the dielectric spectra is almost negligible. In the presented analysis, we characterize the hydration water in terms of hydration number and retardation ratio between relaxation times of hydration and bulk water. Both techniques provide similar estimates of . The retardation imposed on the hydration water by sugars is 3.3 1.3 and involves only water molecules hydrogen-bonded (HB) to solutes ( 3 water molecules per sugar OH-group). In contrast, polar peptides cause longer range erturbations beyond the first hydration shell, and between 2.8 and 8, increasing with the number of chemical groups engaged in HB formation. We demonstrate that chemical heterogeneity and specific HB interactions play a crucial role in hydration dynamics around polar solutes. The obtained results help to disentangle the role of excluded volume and enthalpic contributions in dynamics of hydration water at the interface with biological molecules.

Perticaroli, Stefania↗

The Continual Intercomparison of Radiation Codes: Results from Phase I

We present results from Phase I of the Continual Intercomparison of Radiation Codes (CIRC), intended as an evolving and regularly updated reference source for evaluation of radiative transfer (RT) codes used in Global Climate Models. CIRC differs from previous intercomparisons in that it relies on an observationally validated catalogue of cases. The seven CIRC Phase I baseline cases, five cloud-free, and two with overcast liquid clouds, are built around observations by the Atmospheric Radiation Measurements (ARM) program that satisfy the goals of Phase I, namely to examine radiative transfer (RT) model performance in realistic, yet not overly complex, atmospheric conditions. In addition to the seven baseline cases, additional idealized "subcases" are also examined to facilitate intrepretation of the causes of model errors. In addition to summarizing individual model performance with respect to reference line-by-line calculations and inter-model differences, we also highlight RT model behavior for conditions of doubled CO2, aspects of utilizing a spectral specification of surface albedo, and the impact of the inclusion of scattering in the thermal infrared. Our analysis suggests that RT models should work towards improving their calculation of diffuse shortwave flux, shortwave absorption, treatment of spectral surface albedo, and shortwave CO2 forcing. On the other hand, LW calculations appear to be significantly closer to the reference results. By enhancing the range of conditions under which participating codes are tested, future CIRC phases will hopefully allow even more rigorous examination of RT code performance.

radiative transfer, climate models, radiative forc↗

The systematic study of N/Z dependence on surface diffuseness parameter in the fusion of heavy neutron-rich colliding nuclei

Surface diffuseness parameter used in Woods-Saxon form of potential have been extracted from a large number of experimentally studied neutron-rich fusion cross sections at near barrier energies. The results of our systematic study reveals that the extracted diffuseness parameter depend linearly on the N/Z ratio of the fusing nuclei. Further, we demonstrated that the extracted values of surface diffuseness parameter lies within the range a = 0.40 to 0.77 fm as compared to commonly accepted value form scattering i.e. 0.63 fm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Incoherent Thomson scattering system for PHAse space MApping (PHASMA) experiment

A new incoherent Thomson scattering system measures the evolution of electron velocity distribution functions perpendicular and parallel to the ambient magnetic field during kinking of a single flux rope and merging of two flux ropes through magnetic reconnection. The Thom-son scattering system provides sub-millimeter spatial resolution, sufficient to diagnose the several millimeters sized magnetic reconnection electron diffusion region in the PHAse Space MAppgin experiment. Due to the relatively modest plasma density ~ 10 19 m -3 and electron tem-perature ~1 eV, stray light suppression is critical for these measurements. Two volume Bragg gratings are used in series as a notch filter with a spectral bandwidth <0.1 nm in the collection branch. A CCD with a Gen III intensifier with peak quantum efficiency >47% is used as the detector in a 1.3 m spectrometer. Preliminary results of gun plasma electron temperature will be reported and compared with measurements obtained from a triple Langmuir probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of diffusion of indocyanine green as a photodynamic dye into skin using backscattering spectroscopy

One of the lines of development of modern medicine is theranostics consisting in simultaneous diagnosis and laser treatment with the use of multifunctional agents such as fluorescent indocyanine green that has photodynamic and photothermal properties. Diffusion of indocyanine green dissolved in water and aqueous solutions of alcohols (glycerol, propylene glycol and ethanol) into the dermis is studied by using backscattering spectroscopy. The coefficients of the dye diffusion into the dermis are obtained for the first time by using these solvents. (laser biophotonics)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-nuclear Electron Transport Channels in Hollow Molecules

Electron transport in inorganic semiconductors and metals occurs through delocalized bands formed by overlapping electron orbitals. Strong correlation of electronic wave functions with the ionic cores couples the electron and lattice motions, leading to efficient interaction and scattering that degrades coherent charge transport. By contrast, unoccupied electronic states at energies near the vacuum level with diffuse molecular orbitals may form nearly-free-electron bands with density maxima in non-nuclear interstitial voids, which are subject to weaker electron-phonon interaction. The position of such bands typically above the frontier orbitals, however, renders them unstable with respect to electronic interband relaxation and therefore unsuitable for charge transport. Through electronic-structure calculations, we engineer stable, non-nuclear, nearly-free-electron conduction channels in low-dimensional molecular materials by tailoring their electrostatic and polarization potentials. We propose quantum structures of graphane-derived Janus molecular sheets with spatially isolated conducting and insulating regions that potentially exhibit emergent electronic properties, as a paradigm for molecular-scale non-nuclear charge conductors; we also describe tuning of their electronic properties by application of external fields and calculate their electron–acoustic-phonon interaction.

Environmental Molecular Sciences Laboratory↗

Translation-rotation decoupling and nonexponentiality in room temperature ionic liquids

Using a combination of light scattering techniques and broadband dielectric spectroscopy, we have measured the temperature dependence of structural relaxation time and self diffusion in three imidazolium-based room temperature ionic liquids: [bmim][NTf2], [bmim][PF6], and [bmim][TFA]. A detailed analysis of the results demonstrates that self diffusion decouples from structural relaxation in these systems as the temperature is decreased toward Tg. The degree to which the dynamics are decoupled, however, is shown to be surprisingly weak when compared to other supercooled liquids of similar fragility. In addition to the weak decoupling, we demonstrate that the temperature dependence of the structural relaxation time in all three liquids can be well described by a single Vogel-Fulcher-Tamann function over 13 decades in time from 10 11 s up to 102 s. Furthermore, the stretching of the structural relaxation is shown to be temperature independent over the same range of time scales, i.e., time temperature superposition is valid for these ionic liquids from far above the melting point down to the glass transition temperature.We suggest that these phenomena are interconnected and all result from the same underlying mechanism strong and directional intermolecular interactions.

Griffin, Phillip↗

General features and master equations for structurization in complex dusty plasmas

Dust structurization is considered to be typical for complex plasmas. Homogeneous dusty plasmas are shown to be universally unstable. The dusty plasma structurization instability is similar to the gravitational instability and can results in creation of different compact dust structures. A general approach for investigation of the nonlinear stage of structurization in dusty plasmas is proposed and master equations for the description of self-organized structures are formulated in the general form that can be used for any nonlinear model of dust screening. New effects due to the scattering of ions on the nonlinearly screened grains are calculated: nonlinear ion dust drag force and nonlinear ion diffusion. The physics of confinement of dust and plasma components in the equilibria of compact dust structures is presented and is supported by numerical calculations of master equations. The necessary conditions for the existence of equilibrium structures are found for an arbitrary nonlinearity in dust screening. Features of compact dust structures observed in recent experiments agree with the numerically calculated ones. Some proposals for future experiments in spherical chamber are given.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Code Coverage Status of ARC Code-DIF3D

The Argonne Reactor Code (ARC) software system supports users in their fast reactor design goals by providing neutronic, thermal-hydraulic, and structural analysis capabilities. DIF3D plays a pivotal role in the ARC system as the primary homogenized assembly neutronic calculation methodology for fast reactor problems. Over its 40 years history, ARC software usage with DIF3D has been applied to numerous fast and thermal spectrum reactor analysis projects with good to excellent comparison against experiments. With continued improvement of computation resources, many of the geometry modeling capabilities in DIF3D that were primarily used in low order schemes are not really needed anymore. Today, the diffusion and transport capabilities of DIF3D-VARIANT are primarily used in the reactor design process with some scattered usage of DIF3D-FD and DIF3D-Nodal. In recent work, the DIF3D software verification was completed for DIF3D-FD and DIF3D-VARIANT on the geometry options used in the Versatile Test Reactor project. While we can be confident that these capabilities of DIF3D are well used and thus trusted, it does not demonstrate that all possible input options of DIF3D are actually working, but just those that were tested as part of VTR are and that they are correct. Thus, the purpose of the present work is to identify a set of test problems for DIF3D and assess the code coverage of DIF3D for those test problems. The goal is to document what parts of the existing DIF3D code are touched by the set of test problems and which are not. Because the verification work done on DIF3D-VARIANT and DIF3D-FD was focused on the most common uses of DIF3D for fast reactor analysis, the code coverage assessment of those capabilities is the highest priority. This will ensure that nothing is being missed by the existing verification test problems that DIF3D relies upon. The DIF3D-Nodal capability will also be inspected for code coverage as part of this work to further ensure that regular regression testing of DIF3D will trap any likely errors the end user might experience with the DIF3D software. The code coverage analysis of DIF3D was performed with the Code Coverage Tool of the Intel Fortran compiler which requires modifications to the compilation of DIF3D. The detailed coverage tables are given for each submodule of DIF3D separately, and for the submodules which are primarily developed for DIF3D, most of the source files could be at least partially touched. Most of the uncovered parts/files could be easily ignored, because they are either for error message and debugging output or obviously not needed by DIF3D. Out of the entire source codes of DIF3D, only a few uncovered modules deserve further investigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Code Coverage Status of the ARC Code DIF3D

The Argonne Reactor Code (ARC) software system supports users in their fast reactor design goals by providing neutronic, thermal-hydraulic, and structural analysis capabilities. DIF3D plays a pivotal role in the ARC system as the primary homogenized assembly neutronic calculation methodology for fast reactor problems. Over its 40 years history, ARC software usage with DIF3D has been applied to numerous fast and thermal spectrum reactor analysis projects with good to excellent comparison against experiments. With continued improvement of computation resources, many of the geometry modeling capabilities in DIF3D that were primarily used in low order schemes are not really needed anymore. Today, the diffusion and transport capabilities of DIF3D-VARIANT are primarily used in the reactor design process with some scattered usage of DIF3D-FD and DIF3D-Nodal. In recent work, the DIF3D software verification was completed for DIF3D-FD and DIF3D-VARIANT on the geometry options used in the Versatile Test Reactor project. While we can be confident that these capabilities of DIF3D are well used and thus trusted, it does not demonstrate that all possible input options of DIF3D are actually working, but just those that were tested as part of VTR are and that they are correct. Thus, the purpose of the present work is to identify a set of test problems for DIF3D and assess the code coverage of DIF3D for those test problems. The goal is to document what parts of the existing DIF3D code are touched by the set of test problems and which are not. Because the verification work done on DIF3D-VARIANT and DIF3D-FD was focused on the most common uses of DIF3D for fast reactor analysis, the code coverage assessment of those capabilities is the highest priority. This will ensure that nothing is being missed by the existing verification test problems that DIF3D relies upon. The DIF3D-Nodal capability will also be inspected for code coverage as part of this work to further ensure that regular regression testing of DIF3D will trap any likely errors the end user might experience with the DIF3D software. The code coverage analysis of DIF3D was performed with the Code Coverage Tool of the Intel Fortran compiler which requires modifications to the compilation of DIF3D. The detailed coverage tables are given for each submodule of DIF3D separately, and for the submodules which are primarily developed for DIF3D, most of the source files could be at least partially touched. Most of the uncovered parts/files could be easily ignored, because they are either for error message and debugging output or obviously not needed by DIF3D. Out of the entire source codes of DIF3D, only a few uncovered modules deserve further investigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Code Coverage Status of the ARC Code PERSENT

The Argonne Reactor Code (ARC) software system supports users in their fast reactor design goals by providing neutronic, thermal-hydraulic, and structural analysis capabilities. PERSENT fulfills the role of generating reactivity coefficients for a given time point of a REBUS calculation usable in a point kinetics based safety analysis capability. PERSENT also provides a sensitivity coefficient capability on eigenvalue, reactivity worth, and several other key coefficients that are used in the follow-on safety analysis. Given a co-variance matrix, PERSENT can carry out the uncertainty quantification to indicate the amount of error in the reactivity coefficients derived from the errors in the cross section measurements. With continued improvement of computational resources, many of the geometry modeling capabilities in DIF3D that were primarily used in low order schemes are not really needed anymore. Today, the diffusion and transport capabilities of DIF3D-VARIANT are primarily used in the reactor design process with some scattered usage of DIF3D-FD and DIF3D-Nodal. PERSENT is part of the ARC code system and is built around DIF3D-VARIANT and the flux solution it provides. The purpose of the present work is to identify a set of test problems for PERSENT and assess the code coverage of PERSENT for those test problems. PERSENT treats the DIF3D executable as an external executable and thus the code coverage considerations only need to focus on the PERSENT source code and only a fraction of the connected modules in the existing ARC software library. The goal is to document what parts of the existing PERSENT code are touched by the set of test problems and which are not. Because the verification work done on PERSENT was focused on the most common uses of PERSENT for fast reactor analysis, the code coverage assessment of those capabilities is the highest priority. This will ensure that nothing is being missed by the existing verification test problems that users of PERSENT rely upon. The code coverage analysis of PERSENT was performed with the Code Coverage Tool of the Intel Fortran compiler which requires modifications to the compilation of PERSENT. The detailed coverage tables are given for each submodule of PERSENT. Most of the uncovered parts/files could be easily ignored because they are either for error message and debugging output or not needed by PERSENT today. Only a few uncovered parts of PERSENT deserve extending the verification test suite.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗