Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Convergence Studies of Thermal and Electromagnetic Transient Quench Analysis of 11 GeV Super High Momentum Spectrometer Superconducting Magnets in Jefferson Lab

This paper presents results of convergence studies of transient thermal and electromagnetic quench analysis of five Super High Momentum Spectrometer (SHMS) superconducting magnets: HB, Q1, Q2, Q3, and Dipole, using Vector Fields Quench analysis codes. The convergence of the hot spot temperature and solution solve times were used to investigate the effects of element types, mesh densities, and tolerance criteria. The comparisons between tetrahedral elements and hexahedral elements was studied, and their advantages and disadvantages were discussed. Based on the results of convergence studies, a meshing guideline for coils is presented. The impact of iteration tolerance to the hot spot temperature was also explored, and it is found that tight tolerances result in extremely long solve times with only marginal improvements in the results.

43 PARTICLE ACCELERATORS↗

Electromagnetic Properties of (Gd, Y)Ba2Cu3Ox Superconducting Tapes With High Levels of Zr Addition

The dependence of the critical current density (J(c)) on the orientation of applied magnetic fields was studied in Zr-doped (Gd, Y)Ba2Cu3Ox tapes fabricated by metal organic chemical vapor deposition. The in-field performance of J(c) of (Gd, Y)Ba2Cu3Ox tapes with Zr-doping levels of 7.5-30 at.% was investigated up to 5 T over a temperature range of 40-77 K. The highest critical currents (I-c) at H parallel to c and the highest values of minimum Ic in angular dependence measurements were achieved in the tapes with 20% Zr doping over a broad range of temperature and magnetic field conditions measured. The electromagnetic properties have been related to the changes in BaZrO3 content and microstructure.

Liu, Y↗

An Investigation into the Electromagnetic Interactions between a Superconducting Torus and Solenoid for the Jefferson Lab 12 GeV Upgrade

The Jefferson Lab 12 GeV Upgrade in Hall B will need CLAS12 detector that requires two superconducting magnets. One is a magnet system consisting of six superconducting trapezoidal racetrack-type coils assembled in a Toroidal configuration (Torus) and the second is an actively shielded solenoidal magnet (Solenoid). Both the torus and solenoid are located in close proximity to one another and are surrounded by sensitive detectors. This paper investigates the electromagnetic interactions between the two systems during normal operation as well as during various fault scenarios as part of a Risk Assessment and Mitigation (RAM).

Torus, actively shielded, Solenoid, SSC-NbTi,Ruthe↗

Electromagnetic Properties of Aluminum-based Bilayers for Kinetic Inductance Detectors

The complex conductivity of a superconducting thin film is related to the quasiparticle density, which depends on the physical temperature and can also be modified by external pair breaking with photons and phonons. This relationship forms the underlying operating principle of Kinetic Inductance Detectors (KIDs), where the detection threshold is governed by the superconducting energy gap. We investigate the electromagnetic properties of thin-film aluminum that is proximitized with either a normal metal layer of copper or a superconducting layer with a lower T-C, such as iridium, in order to extend the operating range of KIDs. Using the Usadel equations along with the Nam expressions for complex conductivity, we calculate the density of states and the complex conductivity of the resulting bilayers to understand the dependence of the pair breaking threshold, surface impedance, and intrinsic quality factor of superconducting bilayers on the relative film thicknesses. The calculations and analyses provide theoretical insights in designing aluminum-based bilayer kinetic inductance detectors for detection of microwave photons and athermal phonons at the frequencies well below the pair breaking threshold of a pure aluminum film.

complex conductivity↗

Real-time Electromagnetic Transient Simulation of Multi-Terminal HVDC-AC Grids based on GPU

High-fidelity electromagnetic transient (EMT) simulation plays a critical role in understanding the dynamic behavior and fast transients involved in operation, control, and protection of Multi-Terminal dc (MTdc) grids. Here, this paper proposes a cost-effective high-performance real-time EMT simulation platform for large-scale cross-continental MTdc grids based on graphics processing unit (GPU). The proposed simulation platform: i) assembles detailed EMT models of all components within an MTdc-ac grid into a single platform. This setup provides a complete simulation solution to capture fast transient signals required for high-bandwidth controller design and protection studies without any compromise; ii) implements the first GPU-based simulation architecture and corresponding algorithms for MTdc-ac grids with real-time performance at scales of 1s; iii) is highly-efficient and balances the high utilization of GPU resources and low latency required for the simulation; and iv) outperforms the existing central processing unit (CPU)- or digital signal processor (DSP)/field-programmable gate array (FPGA)-based simulators in terms of its higher scalability on large-scale MTdc-ac grids and superior price-performance ratio on the hardware. Accuracy and performance of the proposed platform are evaluated with respect to the reference results from PSCAD/EMTDC environment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electromagnetic and Engineering Design of a High-Current 15-MeV/u Cyclotron

The capability to produce high current, low loss, and extracted external ion beams presents an enabling technology for nuclear security, isotope production, and medical applications. We report on a novel, continuous-wave cyclotron for accelerating light ions with a charge-to-mass ratio of 1/2, which is designed for 1 mA maximum and 15 MeV/u energy. This article details the conceptual electromagnetic (EM) and engineering design including the 1.1 T sector magnets and 45 MHz, 200 kV radio frequency (RF) cavities. We discuss the cyclotron beam parameters with respect to potential commercial and industrial applications. The general concept and the accelerator’s layout are followed by a detailed EM design of magnets and RF cavities. Finally, practical engineering design considerations will be provided.

07 ISOTOPE AND RADIATION SOURCES↗

Combined Normal and Disruption, Electromagnetic Transient, Thermal, and Structural Analysis of COMPASS Upgrade

We report that COMPASS Upgrade is a replacement for the COMPASS device at the Institute of Plasma Physics (IPP) of the Czech Academy of Sciences. It is a cryogenic copper machine with a major radius of 0.89 m, with 5 T at the plasma centerline and 2-MA plasma current. It is intended to develop ITER relevant plasma densities and high power fluxes in the divertor region. The entire vacuum vessel is planned to reach 500 °C. The COMPASS-U TF coil is a bitter plate-like design with radial conductor plates that extend the width of the TF inner leg. Currents redistribute radially based on resistive and inductive effects. This necessitates an electromagnetic (EM) transient analysis of the coil current distribution. For copper coils like COMPASS Upgrade, the solution must be coupled with a thermal solution to properly include the temperature-dependent resistive effects. The EM transient solution includes the TF magnetic loads, and a stress pass on the results produces in-plane loads. The EM solution chosen requires inclusion of all the conducting and nonconducting regions surrounding the TF coil. With the TF current distribution solved, the addition of the poloidal coils and resulting background fields allows the determination of the out-of-plane loads. Integration of the Joule heating produced from the EM solution produces temperature distributions throughout the shot, which can be read in to a structural pass to include thermal stresses in the evaluation. This is true of both TF and PF temperature prediction with appropriate packing fractions. Currents in the PF coils, with computed background fields, produce Lorentz loads. Time transients of the PF currents produce startup eddy currents in the structures included in the model; inclusion of the vessel and other passive structures allows these to be included in a stress pass. The EM transient solution includes all the elements needed for a disruption analysis with prescribed motions and quench of the plasma. From a model originally intended to simulate current diffusion in the TF coil, the analysis can be refined to be used to predict the performance of most of the components of the tokamak or provide boundary conditions for more detailed submodels. In this article, the use of the current diffusion model for bounding assessments of the COMPASS Upgrade TF, PF, vessel, external structure, and disruption analyses will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electromagnetic Analysis of ITER Electron Cyclotron Emission Model

The ITER electron cyclotron emission (ECE) diagnostic system is located at diagnostics shielding module 2 (DSM2), equatorial port 9 (EP9), to measure electron temperature profile and electron temperature fluctuations, and also assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two hot sources for calibration and two couples of mirrors for two different optical views. It shall receive that the large electromagnetic (EM) loads up to 100-MN/m3 force density due to the eddy currents on the copper mirrors generated by the short transient plasma disruption. The simplified EM analysis model using magnetic field ( B ) data and flux variations (dB/dt) method based on the worst case of plasma disruption, MD_DW_EXP16MS_CATIII, has been developed to calculate the force and moments for each ECE component and support structure for EP9 DSM2 Bay2 and Bay3. The B and dB/dt methods use the constant B and dB/dt assumed for each local bay space, but the real B and dB/dt are basically varied along the radial direction of each bay. The complex global model with the local ECE components and support structure using Maxwell transient has been developed to do EM analysis to compare the results of the B and dB/dt models. The volumetric EM force density of the whole ECE components and support structure can be used for the subsequent structural analysis. In conclusion, combined with the thermal and nuclear loads and seismic and initial loads, the ECE integration analysis can be finalized for the operation case.

Fang, J. [Princeton Plasma Physics Laboratory (PPP↗

Three-dimensional controlled-source electromagnetic and magnetotelluric joint inversion

The growing use of the controlled-source electromagnetic method (CSEM) and magnetotellurics (MT) for exploration applications has been driving the development of data acquisition technologies, and three-dimensional (3-D) modeling and imaging techniques. However, targeting increasingly complex geological environments also further enhances the problems inherent in large-scale inversion, such as non-uniqueness and resolution issues. In this paper, we report on two techniques to mitigate these problems. We use 3-D joint CSEM and MT inversion to improve the model resolution. To avoid the suppression of the resolution capacities of one data type, and thus to balance the use of inherent, and ideally complementary information content, different data reweighting schemes are proposed. Further, a hybrid model parameterization approach is presented, where traditional cell-based model parameters are used simultaneously within a parametric inversion. The idea is to limit the non-uniqueness problem, typical for 3-D imaging problems, in order to allow for a more focusing inversion. The methods are demonstrated using synthetic data generated from models with a strong practical relevance.

54 ENVIRONMENTAL SCIENCES↗

Developing Uncertainty Quantification Strategies in Electromagnetic Problems Involving Highly Resonant Cavities

High-quality factor resonant cavities are challenging structures to model in electromagnetics owing to their large sensitivity to minute parameter changes. Therefore, uncertainty quantification (UQ) strategies are pivotal to understanding key parameters affecting the cavity response. Furthermore, we discuss here some of these strategies focusing on shielding effectiveness (SE) properties of a canonical slotted cylindrical cavity that will be used to develop credibility evidence in support of predictions made using computational simulations for this application.

47 OTHER INSTRUMENTATION↗

Electromagnetic effects in high-frequency large-area capacitive discharges: A review

In traditional capacitively coupled plasmas, the discharge can be described by an electrostatic model, in which the Poisson equation is employed to determine the electrostatic electric field. However, current plasma reactors are much larger and driven at a much higher frequency. If the excitation wavelength λ in the plasma becomes comparable to the electrode radius, and the plasma skin depth δ becomes comparable to the electrode spacing, the electromagnetic (EM) effects will become significant and compromise the plasma uniformity. In this regime, capacitive discharges have to be described by an EM model, i.e., the full set of Maxwell's equations should be solved to address the EM effects. This paper gives an overview of the theory, simulation and experiments that have recently been carried out to understand these effects, which cause major uniformity problems in plasma processing for microelectronics and flat panel display industries. Furthermore, some methods for improving the plasma uniformity are also described and compared.

42 ENGINEERING↗

Determination of action thresholds for electromagnetic tracking system-guided hypofractionated prostate radiotherapy using volumetric modulated arc therapy

Purpose: Hypofractionated prostate radiotherapy may benefit from both volumetric modulated arc therapy (VMAT) due to shortened treatment time and intrafraction real-time monitoring provided by implanted radiofrequency(RF) transponders. The authors investigate dosimetrically driven action thresholds (whether treatment needs to be interrupted and patient repositioned) in VMAT treatment with electromagnetic (EM) tracking. Methods: VMAT plans for five patients are generated for prescription doses of 32.5 and 42.5 Gy in five fractions. Planning target volume (PTV) encloses the clinical target volume (CTV) with a 3 mm margin at the prostate-rectal interface and 5 mm elsewhere. The VMAT delivery is modeled using 180 equi-spaced static beams. Intrafraction prostate motion is simulated in the plan by displacing the beam isocenter at each beam assuming rigid organ motion according to a previously recorded trajectory of the transponder centroid. The cumulative dose delivered in each fraction is summed over all beams. Two sets of 57 prostate motion trajectories were randomly selected to form a learning and a testing dataset. Dosimetric end points including CTV D95%, rectum wall D1cc, bladder wall D1cc, and urethra Dmax, are analyzed against motion characteristics including the maximum amplitude of the anterior-posterior (AP), superior-inferior (SI), and left-right components. Action thresholds are triggered when intrafraction motion causes any violations of dose constraints to target and organs at risk (OAR), so that treatment is interrupted and patient is repositioned. Results: Intrafraction motion has a little effect on CTV D95%, indicating PTV margins are adequate. Tight posterior and inferior action thresholds around 1 mm need to be set in a patient specific manner to spare organs at risk, especially when the prescription dose is 42.5 Gy. Advantages of setting patient specific action thresholds are to reduce false positive alarms by 25% when prescription dose is low, and increase the sensitivity of detecting dose limits violations by 30% when prescription dose is high, compared to a generic 2 mm action box. The sensitivity and specificity calculated from the testing dataset are consistent to the learning set, which indicates that the patient specific approach is reliable and reproducible within the scope of the prostate database. Conclusions: This work introduces a formalism for ensuring a VMAT delivery meets the most clinically important dose requirements by using patient specific and dosimetric-driven action thresholds to hold the beam and reposition the patient when necessary. Such methods can provide improved sensitivity and specificity compared to conventional methods, which assume directionally symmetric action thresholds.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-A-17A-10: Fast, Automatic and Accurate Catheter Reconstruction in HDR Brachytherapy Using An Electromagnetic 3D Tracking System

Purpose: In high dose rate brachytherapy (HDR-B), actual catheter reconstruction protocols are slow and errors prompt. The purpose of this study was to evaluate the accuracy and robustness of an electromagnetic (EM) tracking system for improved catheter reconstruction in HDR-B protocols. Methods: For this proof-of-principle, a total of 10 catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a Philips-design 18G biopsy needle (used as an EM stylet) and the second generation Aurora Planar Field Generator from Northern Digital Inc. The Aurora EM system exploits alternating current technology and generates 3D points at 40 Hz. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical CT system with a resolution of 0.089 mm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, 5 catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 seconds or less. This would imply that for a typical clinical implant of 17 catheters, the total reconstruction time would be less than 3 minutes. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.92 ± 0.37 mm and 1.74 ± 1.39 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be significantly more accurate (unpaired t-test, p < 0.05). A mean difference of less than 0.5 mm was found between successive EM reconstructions. Conclusion: The EM reconstruction was found to be faster, more accurate and more robust than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators. We would like to disclose that the equipments, used in this study, is coming from a collaboration with Philips Medical.

07 ISOTOPE AND RADIATION SOURCES↗

Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora{sup ®} Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.

60 APPLIED LIFE SCIENCES↗

SU-F-BRA-03: Integrating Novel Electromagnetic Tracking Hollow Needle Assistance in Permanent Implant Brachytherapy Procedures

Purpose: To report on the results of a complete permanent implant brachytherapy procedure assisted by an electromagnetic (EM) hollow needle possessing both 3D tracking and seed drop detection abilities. Methods: End-to-end in-phantom EM-assisted LDR procedures were conducted. The novel system consisted of an EM tracking apparatus (NDI Aurora V2, Planar Field Generator), a 3D US scanner (Philips CX50), a hollow needle prototype allowing 3D tracking and seed drop detection and a specially designed treatment planning software (Philips Healthcare). A tungsten-doped 30 cc spherical agarose prostate immersed in gelatin was used for the treatment. A cylindrical shape of 0.8 cc was carved along its diameter to mimic the urethra. An initial plan of 26 needles and 47 seeds was established with the system. The plan was delivered with the EM-tracked hollow needle, and individual seed drop locations were recorded on the fly. The phantom was subsequently imaged with a CT scanner from which seed positions and contour definitions were obtained. The DVHs were then independently recomputed and compared with those produced by the planning system, both before and after the treatment. Results: Of the 47 seeds, 45 (96%) were detected by the EM technology embedded in the hollow needle design. The executed plan (from CT analysis) differed from the initial plan by 2%, 14% and 8% respectively in terms of V100, D90 and V150 for the prostate, and by 8%, 7% and 10% respectively in terms of D5, V100 and V120 for the urethra. Conclusion: The average DVH deviations between initial and executed plans were within a 5% tolerance imposed for this proof-of-concept assessment. This relatively good concordance demonstrates the feasibility and potential benefits of combining EM tracking and seed drop detection for real-time dosimetry validation and assistance in permanent implant brachytherapy procedures. This project has been entirely funded by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

TU-AB-201-03: A Robot for the Automated Delivery of An Electromagnetic Tracking Sensor for the Localization of Brachytherapy Catheters

Purpose: To present a programmable robotic system for the accurate and fast deployment of an electromagnetic (EM) sensor for brachytherapy catheter localization. Methods: A robotic system for deployment of an EM sensor was designed and built. The system was programmed to increment the sensor position at specified time and space intervals. Sensor delivery accuracy was measured in a phantom using the localization of the EM sensor and tested in different environmental conditions. Accuracy was tested by measuring the distance between the physical locations reached by the sensor (measured by the EM tracker) and the intended programmed locations. Results: The system consisted of a stepper motor connected to drive wheels (that grip the cable to move the sensor) and a series of guides to connect to a brachytherapy transfer tube, all controlled by a programmable Arduino microprocessor. The total cost for parts was <$300. The positional accuracy of the sensor location was within 1 mm of the expected position provided by the motorized guide system. Acquisition speed to localize a brachytherapy catheter with 20 cm of active length was 10 seconds. The current design showed some cable slip and warping depending on environment temperature. Conclusion: The use of EM tracking for the localization of brachytherapy catheters has been previously demonstrated. Efficient data acquisition and artifact reduction requires fast and accurate deployment of an EM sensor in consistent, repeatable patterns, which cannot practically be achieved manually. The design of an inexpensive, programmable robot allowing for the precise deployment of stepping patterns was presented, and a prototype was built. Further engineering is necessary to ensure that the device provides efficient independent localization of brachytherapy catheters. This research was funded by the Kaye Family Award.

60 APPLIED LIFE SCIENCES↗

Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator

Purpose: Couch and MLC tracking are two promising methods for real-time motion compensation during radiation therapy. So far, couch and MLC tracking experiments have mainly been performed by different research groups, and no direct comparison of couch and MLC tracking of volumetric modulated arc therapy (VMAT) plans has been published. The Varian TrueBeam 2.0 accelerator includes a prototype tracking system with selectable couch or MLC compensation. This study provides a direct comparison of the two tracking types with an otherwise identical setup. Methods: Several experiments were performed to characterize the geometric and dosimetric performance of electromagnetic guided couch and MLC tracking on a TrueBeam accelerator equipped with a Millennium MLC. The tracking system latency was determined without motion prediction as the time lag between sinusoidal target motion and the compensating motion of the couch or MLC as recorded by continuous MV portal imaging. The geometric and dosimetric tracking accuracies were measured in tracking experiments with motion phantoms that reproduced four prostate and four lung tumor trajectories. The geometric tracking error in beam’s eye view was determined as the distance between an embedded gold marker and a circular MLC aperture in continuous MV images. The dosimetric tracking error was quantified as the measured 2%/2 mm gamma failure rate of a low and a high modulation VMAT plan delivered with the eight motion trajectories using a static dose distribution as reference. Results: The MLC tracking latency was approximately 146 ms for all sinusoidal period lengths while the couch tracking latency increased from 187 to 246 ms with decreasing period length due to limitations in the couch acceleration. The mean root-mean-square geometric error was 0.80 mm (couch tracking), 0.52 mm (MLC tracking), and 2.75 mm (no tracking) parallel to the MLC leaves and 0.66 mm (couch), 1.14 mm (MLC), and 2.41 mm (no tracking) perpendicular to the leaves. The motion-induced gamma failure rate was in mean 0.1% (couch tracking), 8.1% (MLC tracking), and 30.4% (no tracking) for prostate motion and 2.9% (couch), 2.4% (MLC), and 41.2% (no tracking) for lung tumor motion. The residual tracking errors were mainly caused by inadequate adaptation to fast lung tumor motion for couch tracking and to prostate motion perpendicular to the MLC leaves for MLC tracking. Conclusions: Couch and MLC tracking markedly improved the geometric and dosimetric accuracies of VMAT delivery. However, the two tracking types have different strengths and weaknesses. While couch tracking can correct perfectly for slowly moving targets such as the prostate, MLC tracking may have considerably larger dose errors for persistent target shift perpendicular to the MLC leaves. Advantages of MLC tracking include faster dynamics with better adaptation to fast moving targets, the avoidance of moving the patient, and the potential to track target rotations and deformations.

60 APPLIED LIFE SCIENCES↗

Distinguishing surface and bulk electromagnetism via their dynamics in an intrinsic magnetic topological insulator

The indirect exchange interaction between local magnetic moments via surface electrons has been long predicted to bolster the surface ferromagnetism in magnetic topological insulators (MTIs), which facilitates the quantum anomalous Hall effect. This unconventional effect is critical to determining the operating temperatures of future topotronic devices. However, the experimental confirmation of this mechanism remains elusive, especially in intrinsic MTIs. Here, we combine time-resolved photoemission spectroscopy with time-resolved magneto-optical Kerr effect measurements to elucidate the unique electromagnetism at the surface of an intrinsic MTI MnBi 2 Te 4 . Theoretical modeling based on 2D Ruderman-Kittel-Kasuya-Yosida interactions captures the initial quenching of a surface-rooted exchange gap within a factor of two but overestimates the bulk demagnetization by one order of magnitude. This mechanism directly explains the sizable gap in the quasi-2D electronic state and the nonzero residual magnetization in even-layer MnBi 2 Te 4 . Furthermore, it leads to efficient light-induced demagnetization comparable to state-of-the-art magnetophotonic crystals, promising an effective manipulation of magnetism and topological orders for future topotronics.

74 ATOMIC AND MOLECULAR PHYSICS↗