At least 1,531 records · Page 85

APPLICATION OF MATURITY MODELS FOR EVALUATING CYBERSECURITY PROGRAMS AT NUCLEAR AND RADIOLOGICAL FACILITIES

Maturity models can be used to provide government agencies, industry associations, and organizations operating nuclear facilities with the ability to quickly evaluate the maturity of their cybersecurity programs and identify areas to prioritize for improvement. The Cybersecurity Capability Maturity Model (C2M2) was developed by the U.S. Department of Energy to allow organizations in the energy sector to evaluate the programmatic capabilities of their cybersecurity programs in a consistent manner, communicate programmatic maturity information, prioritize cybersecurity investments in targeted areas of concern, and track how the maturity of their cybersecurity program evolves over time. The C2M2 is designed for use by any critical infrastructure organization regardless of ownership, structure, or size. The C2M2 can be easily fine-tuned to access the maturity of nuclear cybersecurity programs and their application at individual facilities. Built on a foundation of existing cybersecurity standards, frameworks, programs, and initiatives, the model features 10 security domains. Performance in each security domain is characterized using a structured set of cybersecurity practices that represent activities an organization can perform to improve cybersecurity in their domain. Each practice can be quickly evaluated as being either fully, largely, partially, or not implemented. Once practices are evaluated for each security domain, the model defines four maturity indicator levels that apply independently to each domain in the model. To earn a maturity level in a given domain, an organization must adequately perform all the practices for that maturity level and its predecessor level(s). A small assessment team can conduct a C2M2 assessment in a single day. A screening version of the C2M2 allows an initial look at the maturity of nuclear cybersecurity programs that could be completed in under an hour.

Cyber security, Nuclear security, maturity model↗

Evaluation of Centralized Model-Based FLISR in a Lab Setup: Preprint

Utilities are installing advanced distribution management systems (ADMS) around the globe to improve the sensing and control of distribution systems. ADMS is becoming a critical component to improve the resiliency and reliability of distribution systems. These management systems host a multitude of applications that can be used to sense, control, and operate distribution systems. Fault location, isolation, and service restoration (FLISR) is one of the ADMS applications that is critical to improving resilience during fault conditions. FLISR applications use smart, controllable devices that are installed in the distribution system for FLISR operation. These controllable devices include distributed energy resources (DER) and reclosers. Evaluating such ADMS applications before installation in the field can help de-risk the field implementation and avoid costly failures in the field. This paper presents a background on experimental setup that are typically used to evaluate ADMS applications. This is followed by briefly presenting the setup used to evaluate the FLISR application in an off-the-shelf ADMS tool. Finally, results from the evaluation experiments are presented.

94 GMLC - Grid Modernization Laboratory Consortium↗

Fiber Orientation Evaluation in Reinforced Composites using Digital Image Correlation

This paper presents an innovative nondestructive evaluation (NDE) approach to evaluate fiber orientation in fiber reinforced composites utilizing digital image correlation (DIC). Fiber orientation is a crucial factor that influences the mechanical and thermal properties of the composite. Conventional methods for fiber orientation evaluation and measurement are either destructive, which are typically laborious. NDE methods such as micro computed tomography are expensive and limited in sample size. In this work, we evaluate two methods of excitation of the composite, namely-quasistatic mechanical loading and thermal cycling. Digital Image Correlation (DIC) has been employed in conjunction for fiber orientation measurements. The DIC system is able to measure the fiber orientation by capturing 19x higher strain in the transverse direction of the reinforced fiber axis during excitation. The larger strain occurs in the transverse direction due to larger elongation in the surrounding polymer matrix than the fiber which resists elongation. This innovative method is within the preliminary stage and has been developed to fill the gap/limitations of other NDE methods.

Spencer, Ryan↗

Evaluation of Thermal Neutron Scattering Law and Cross Sections for Calcium Hydride

Presented in this paper are the calculated thermal scattering law (TSL) and thermal neutron scattering cross sections for Calcium Hydride, hereafter referred to by its chemical symbol CaH 2 . The only other such data prior to this evaluation are thermal neutron scattering libraries in the JEFF database, which suffer from nonphysical features and inaccuracies. The data in this evaluation are calculated from first principles; Density Functional Theory (DFT) is used to calculate the phonon density of states (DOS), which is the primary input required to calculate the TSL. The TSL and cross sections have been evaluated for the three non-equivalent atom cites in the CaH 2: Ca, H 1 , and H 2 . Each evaluation has been submitted to the NNDC for consideration in the next ENDF/B release.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Distributed PV Hosting Capacity Evaluation Considering Equitable PV Accommodation: Preprint

In distribution systems, distributed photovoltaic (DPV) hosting capacity is widely used by system operators to evaluate how much DPV the distribution networks can accommodate without violating operational constraints. With the proliferation of DPV deployment, if managed properly, it offers a great opportunity to mitigate the persistent energy inequity issue in electric grid. Otherwise, energy inequity can be exacerbated with unequal DPV access when hosting capacity improvement plans ignore the equity factor. To consider energy equity in distribution network planning for enhancing DPV accommodation, the hosting capacity evaluation should be improved to consider equity constraints endogenously. In this paper, a DPV hosting capacity evaluation method is proposed considering equitable DPV access among sub-regions of a distribution feeder partitioned by social-economic indicators such as the income levels. The results demonstrate that considering equity in DPV hosting capacity evaluation can provide valuable reference in the equitable energy transition. This work provides a valuable guidance for future distribution network upgrade planning for equitable DPV deployment.

distributed PV↗

Risk-Based Information to Support the Evaluation of Management Options for Cesium and Strontium Capsules at the Hanford Site

Evaluations are under way to support U.S. Department of Energy decisions on how to manage cesium and strontium capsules currently in storage at the Hanford site. Health-based exposure limits for drinking water, oral toxicity data, and environmental fate information were combined in an initial evaluation to frame performance targets for managing chemicals and radionuclides that could leach from the capsules and migrate to groundwater over time. More than 50 relevant benchmarks were identified for 15 of the 17 contaminants in the study set. Of those multiple benchmarks, EPA limits for drinking water served as the main basis for the leachate performance targets. For the remaining two contaminants, stable cesium and zirconium, preliminary indicators were derived from a limited review of toxicity data. Thus, preliminary candidate concentrations were identified for the full study set to support the ongoing evaluation of capsule management options. In summary: In an earlier scoping study, three radionuclides and eight chemicals were identified as contaminants of interest for leachate from cesium and strontium capsules stored at the Hanford site. To frame management options for these capsules, it is assumed that contaminants will leach to groundwater and serve as a drinking water source in the long-term future. Before developing performance targets for the initial set of contaminants, a combined fate and toxicity evaluation was conducted to determine if any others should be added to account for decay or fate products and chemical toxicity. From this review, the list was expanded to produce a final study set of 17 contaminants. Established exposure limits and toxicity data were then reviewed and integrated to develop candidate health-based concentrations to frame performance targets for assessing options for long-term capsule management. This review of more than a dozen different benchmarks and toxicity sources translated to hundreds of individual data checks to support the identification of these target concentrations. In most cases, an EPA drinking water standard served as the key basis for the suggested target. Exceptions were warranted when the drinking water standard reflects dated information and more recent studies suggest a different concentration. Thus, for contaminants with older limits (such as Sr-90), the drinking water standard is identified and an alternate value is also provided that reflects more recent scientific knowledge. Although multiple limits or guidelines exist for most study chemicals, no benchmarks were found for stable cesium or zirconium. Thus, the preliminary target concentrations for these two metals were based on an initial limited review of toxicity data from the scientific literature. In conclusion, fate and toxicity information can be effectively integrated to develop target concentrations for managing contaminated materials at cleanup sites. These targets are simply intended to serve as guides, not as part of a formal compliance review process. For this reason, to the extent possible, it is useful to incorporate current health-based information relevant to the given application. For the Hanford application, it is expected that the preliminary targets will be refined to reflect evolving knowledge. That knowledge may extend from additional characterization of the capsules and their disposition options, and further context for setting-related conditions, to the refinement of benchmarks and underlying models, and further toxicity assessments. The overall goal is to support technical risk analyses for Hanford with current scientific knowledge and practice, to assure health protection into the long term. (authors)

54 ENVIRONMENTAL SCIENCES↗

A high-fidelity Monte Carlo evaluation of CANDU-6 safety parameters

Important safety parameters such as the fuel temperature coefficient (FTC) and the power coefficient of reactivity (PCR) of the CANDU-6 (CANada Deuterium Uranium) reactor have been evaluated by using a modified MCNPX code. For accurate analysis of the parameters, the DBRC (Doppler Broadening Rejection Correction) scheme was implemented in MCNPX in order to account for the thermal motion of the heavy uranium nucleus in the neutron-U scattering reactions. In this work, a standard fuel lattice has been modeled and the fuel is depleted by using the MCNPX and the FTC value is evaluated for several burnup points including the mid-burnup representing a near-equilibrium core. The Doppler effect has been evaluated by using several cross section libraries such as ENDF/B-VI, ENDF/B-VII, JEFF, JENDLE. The PCR value is also evaluated at mid-burnup conditions to characterize safety features of equilibrium CANDU-6 reactor. To improve the reliability of the Monte Carlo calculations, huge number of neutron histories are considered in this work and the standard deviation of the k-inf values is only 0.5{approx}1 pcm. It has been found that the FTC is significantly enhanced by accounting for the Doppler broadening of scattering resonance and the PCR are clearly improved. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A radiating shock evaluated using Implicit Monte Carlo Diffusion

Implicit Monte Carlo [1] (IMC) has been shown to be very expensive when used to evaluate a radiation field in opaque media. Implicit Monte Carlo Diffusion (IMD) [2], which evaluates a spatial discretized diffusion equation using a Monte Carlo algorithm, can be used to reduce the cost of evaluating the radiation field in opaque media [2]. This work couples IMD to the hydrodynamics equations to evaluate opaque diffusive radiating shocks. The Lowrie semi-analytic diffusive radiating shock benchmark[a] is used to verify our implementation of the coupled system of equations. (authors)

97 MATHEMATICS AND COMPUTING↗

Evaluation of Neutron Flux on the Surface of a PWR Dry Storage Cask - 17574

Since the construction of a dry storage facility for spent nuclear fuel is expected in Korea, several methods have been studied for assuring the safety of pressurized-water reactor (PWR) spent fuels in dry storage casks. Existing evaluation methods are mostly based on detection technology of gamma-rays. However, the gamma-ray detection methods have high uncertainties due to background radiation. Therefore, we developed an evaluation method for the spent nuclear fuel monitoring based on neutron detection. In this study, we evaluated neutron flux on the surface of a PWR dry storage cask using computational simulation. Neutron release rate and energy spectra from a Westinghouse (WH) 17x17 type spent fuel with 10 years cooling time were calculated using ORIGEN-ARP code. MCNP code was used to simulate geometry and material properties of the spent fuel assemblies and casks. Neutron flux after 10 years of cooling time of the spent fuels was calculated on the surface of top, side, and bottom of the casks. The metal cask and the concrete cask, called as KORAD-21 casks which newly developed by Korea Radioactive Waste Agency (KORAD), were selected for this study. As a result, for the metal cask, average neutron flux were 4.79x10{sup 2} neutrons/cm{sup 2} sec, 5.29x10{sup 2} neutrons/cm{sup 2} sec, and 1.47x10{sup 3} neutrons/cm{sup 2} sec on the surface of top, side, and bottom of the cask, respectively. For the concrete cask, average neutron flux on the surface of top, side and bottom of the casks were 5.07x10{sup 1} neutrons/cm{sup 2} sec, 1.18x10{sup 1} neutrons/cm{sup 2} sec, and 1.46x10{sup 3} neutrons/cm{sup 2} sec, respectively. The study results can be applied to evaluate characteristics of PWR spent fuels and the neutron flux of dry storage cask. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Site selection in Germany - Start of the evaluation of the site selection law - 15561

Since 2011 Germany is pursuing a phase out strategy concerning the use of nuclear power for electricity production. This decision was strongly influenced by the Fukushima event. In 2013 the federal government announced that they also had achieved an agreement with the Federal States in Germany on a law to restart the site selection for a repository for spent fuel and high active heat producing waste from scratch. The consequence of this law is a delay of at least two decades to start operation of a final disposal site and additional costs of at least EUR 2.7 billion. The new law was passed in July 2013. At first a 34-member commission had been installed in April 2014 to evaluate the Site Selection Law and to develop basic principles for site selection, including safety requirements and selection criteria for rock formations. The commission includes representatives from the parliament, academia, civil society organizations, industry, the environmental organizations and trade unions and should forward its recommendations after a delay in starting the evaluation process now in 2016. The first author of this paper is member of the evaluation commission. The present law has to be reviewed within this time span. The site selection then might start after the next federal election in 2017 probably based on a new site selection law. This new site selection law will take into account or even follow the recommendations of the evaluation group. A new repository site should be according to the present law determined till 2031 and for this site the more detailed site investigation will take place followed by a detailed safety analysis, before the erection of the repository can start. Based on the present procedural steps it seems to be rather unlikely to determine a repository site till 2031. As shown in this publication, there will be a delay of at least 20 years compared to the schedule given in the site selection law until a repository site can be determined. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of interfacial area transport models for horizontal bubbly flow

This paper presents evaluation results of interfacial area transport equation (IATE) for horizontal air-water bubbly flow. The steady-state one-dimensional, one-group IATE for adiabatic air-water bubbly flow developed by Talley [1] is employed in the current evaluation study. The models evaluated include: (a) drift-flux-based closure relations for void-weighted bubble velocity and void fraction; (b) frictional pressure drop model based on the Lockhart-Martinelli approach; (c) bubble interaction mechanisms; and (d) covariance associated with asymmetric bubble distribution in horizontal two-phase flow. In order to evaluate the models, a local two-phase flow database obtained by the four-sensor conductivity probe in fourteen different test conditions is employed, which covers a wide range of flow conditions in horizontal bubbly flow regime, with superficial liquid and gas velocities ranging from 3.50-6.00 m/s and 0.09- 1.00 m/s, respectively. It is demonstrated that both the void weighted bubble velocity and void fraction are predicted well with an average percent difference of ±2.7%. The fictional pressure loss can be predicted with an average percent difference of ±1.12%. The covariance parameters calculated from the modeling approach generally compare well with those calculated from experimental data within ±20% difference. It is found that the IATE generally predicts the measured interfacial area concentration with an average percent difference of ±5.7%. Furthermore, the effect of liquid velocity on individual bubble interaction mechanisms is investigated. It is found that both the contributions of random collision and turbulent impact decrease as liquid velocity decreases. (authors)

42 ENGINEERING↗

Benchmarking of the Updated Resolved Resonance Region Evaluations of Copper

A new resolved resonance region (RRR) evaluation for the two naturally occurring isotopes of copper, {sup 63}Cu and {sup 65}Cu was performed at Oak Ridge National Laboratory (ORNL), and the benchmarking results based on the four highly enriched uranium (HEU), intermediate spectrum, copper-reflected Zeus experiments were presented in June 2014. Since then, two significant updates to the evaluations have been performed: first, the data for the experimental measurement of the capture cross section between 220 keV and 300 keV were renormalized and the resonance parameters were refitted. Second, the angular distribution of elastic scattering initially reported in point-wise form in File 4 of the ENDF file format with high fidelity was significantly reduced in size to allow for better computer storage. Twenty-seven criticality safety benchmarks from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) were calculated using these updated resolved resonance region evaluations for the two isotopes of copper. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance Evaluation of AG-1 FC Filters Under Upset Conditions and the Effects of Aging on Filters - 19501

High efficiency particulate air (HEPA) filters are routinely used in nearly every operating Department of Energy (DOE) and National Nuclear Safety Administration (NNSA) nuclear facility. These nuclear grade HEPA filters installed in DOE and NNSA confinement ventilation systems are credited as the final barrier to protect the environment, the public, and the worker from accidental release of virtually all airborne radioactive materials, and must meet the American Society of Mechanical Engineers' (ASME) Code on Nuclear Air and Gas Treatment (CONAGT) AG-1 standard. This testing activity evaluates ASME AG-1 Section FC axial flow HEPA filters, both separator and separator-less, under upset conditions. Additionally, testing efforts have analyzed the effects of filter degradation due to aging. In 1997, the Defense Nuclear Facilities Safety Board (DNFSB) raised concerns of the potential vulnerability of HEPA filters in vital safety systems, both from a design stand point and the potential for degradation of HEPA filter performance over time. The DOE Office of Environmental Management (DOE-EM) has a Cooperative Agreement with Mississippi State University (MSU) Institute for Clean Energy Technology (ICET) to conduct testing of HEPA filters. DOE-EM has established a Technical Working Group (TWG) of over thirty subject matter experts from the nuclear industry to provide input and oversight of ICET projects and activities. This has included establishment/approval of testing parameters for evaluating these filters under ASME NQA-1 compliant Test Plans. The current scope of work involves evaluation of the performance envelope for new and aged separator and separator-less designs of AG-1 Section FC axial flow HEPA filters. A range of elevated test conditions (T and RH) are used to determine the operating envelope within which DOE nuclear safety experts can credit installed HEPA filter performance, thereby establishing a risk-informed DOE service life. This paper will present preliminary test results of new and aged axial flow filters tested at ICET. Results in this paper include data collected from new separator and separator-less type FC HEPA filters and equivalent test data for a limited group of aged separator and separator-less type FC HEPA filters. Testing for both scopes of work evaluate initial filter performance under ambient conditions of temperature (60 deg. F - 80 deg. F (∼16 - ∼27 deg. C)) and relative humidity (40-60%), loading of each filter with Aluminum Trihydroxide, Al(OH)3, to a specified differential pressure, and then exposing the filter to specified elevated temperature and relative humidity conditions. In addition to the upset conditions of elevated temperature and relative humidity, the performance of HEPA filters under fire scenarios is not well characterized. ICET is currently designing a burn box and testing apparatus to study the effects of fire from burning liquids and a wide range of blends of combustible solids. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluating situation awareness in the control room: the development and initial testing of the process awareness and situation understanding (PASU) measure - 267

What should we ask the control room crew about when evaluating situation awareness? Currently available freeze probe techniques concentrate on trends of process parameters. Analysis of control room work shows that there are far more involved in control room crews' Situation Awareness (SA). The Process Awareness and Situation Understanding (PASU) measure has been developed from an analysis of control room work and includes probing the crew about the status of safety functions and main plant systems such as coolant supply, ordinary and emergency power supply, main reactor parameters, and main plant parameters. Results from a nuclear control room evaluation showed that the crew's overview of safety functions developed differently across scenario phases compared to the crew's overview of main process parameters. SA in the nuclear control room seems to be a multifaceted phenomenon and valid measurement needs to cover its aspects. Initial empirical testing showed that PASU was sensitive to scenario phases and related to other performance indicators. PASU, or measures based on similar principles, can be a valid and useful probe based technique for use in the evaluation of control room design and control room work. The measure will fill a gap in the research literature and will serve as an example of SA measurement with utility for control room evaluation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluating Age Effects on HEPA Filter Performance

Nuclear grade high efficiency particulate air (HEPA) filters are routinely employed as the final control element in confinement ventilation systems. The traditional HEPA filter utilizes a pleated filter medium of fibrous glass that has been produced in a manner analogous to manufacturing paper. These filters are the physically weakest element in a containment ventilation system. Containment ventilation systems are designed to condition the air-stream (temperature, relative humidity, moisture, particle size distribution of aerosols, and aerosol concentration) to levels/conditions that fibrous glass HEPA filters can handle. Approximately 6000 nuclear grade HEPA filters are purchased each year for use in the DOE/NNSA complex. Additional filters are purchased for use in commercial nuclear power generation and ventilation systems of other nuclear applications. These filters are designed and tested in accordance with the American Society of Mechanical Engineers (ASME) AG-1 Code Nuclear Air and Gas Treatment. This code establishes design requirements and qualification procedures. Qualification testing of axial flow filters is described in paragraphs 5000 and following of AG-1. The series of qualification tests are intended to describe the operating envelope of HEPA filters and verify the reliability of a filter design. AG-1 qualification also confirms the pedigree of components used in manufacture for that filter design. The collective set of qualification tests establishes the assumed operating envelope for AG-1 filters. The effects of age on HEPA filter performance have been a concern for at least two decades. A combination of physical evaluation of aged filter media and a review of filter failure records resulted in Appendix C of the Nuclear Air Cleaning Handbook (NACH), Determination of HEPA Filter Life. This states that HEPA filters are not to be used beyond 10 years from the date of manufacture. Additionally, filters put into service in locations where they may become wet are to be taken out of service five years from date of manufacture. Filters that have become wet are to be taken out of service immediately. Finally, it should also be pointed out that filters held in Level B storage are subject to the same 10-year service life. Very limited bench-scale testing in the 1990's raised concern that aging HEPA filters do not have the strength to withstand an accident scenario. In May of 1999, the DNFSB released a Technical Report 23 entitled HEPA Filters Used in the Department of Energy's Hazardous Facilities. This report expressed concerns for the potential vulnerability of HEPA filters in vital safety systems. Concerns and uncertainty associated with degradation of HEPA filter performance over time led the DOE sites to limit HEPA filter service life to 10 years from the date of manufacture or five years in cases where filters may become wet. Establishment of a conservative service life needs to be based on data from a structured series of tests comparing the performance envelope of new and aged full-scale filters. A service life that is insufficiently conservative endangers workers and the public. One that is excessively conservative costs can cause hundreds of otherwise unnecessary filter changes. This increases exposure of employees, disrupts facility operations, and increase disposal costs by millions of dollars annually. Conclusive data are needed to resolve uncertainty associated with the damaging effects of aging on durability of HEPA filters. Therefore, this study needs to provide a sufficient body of evidence to allow DOE and site professionals to make prudent decisions. An updated version of ASME AG-1 Section FC included a non-mandatory appendix that would include the DOE guidance for service life of HEPA filters. Balloting of this revision generated significant resistance to inclusion of any kind of service life language citing the lack of supporting experimental data. Efforts to resolve negative votes failed and resistance to acceptance of the language increased. The result has been to not include service language in Section FC and requests to remove it from sections that already include such language. The recent activity of the ASME AG-1 Committee on Nuclear Air and Gas Treatment effectively de-emphasizes following DoE's service life guidelines. The DOE Office of Nuclear Safety under its NSR and D program provided the Mississippi State University Institute for Clean Energy Technology (ICET) finding to initiate a study to determine the effects of aging on AG-1 axial flow filters just prior to actions taken within the AG-1 committee regarding service life. The NSR and D funding facilitated timely development of a national technical working group comprised of members from the regulatory community, DOE complex, and commercial power to resolve uncertainty associated with effects of aging. The Department of Energy Office of Environmental Management (DOE-EM) has been funding the ICET to evaluate the performance envelope for AG-1 HEPA filters. ICET is one of DOE-EM's qualified suppliers. Synergy has been achieved by associating the NSR and D aged filter activities to testing activities evaluating the performance envelopes of separator and separator-less AG-1 HEPA filters funded by DOE-EM. The DOE-EM funded activities establish baseline data for the aged filter study and future EM funding will provide long term support for testing additional aged filters. EM funding of new filters includes analytical evaluation of media tensile strength by thermal analysis to establish baseline values and determine mass loss of moisture resistance and acrylic binders due to use. All of these values can be used for comparison of test results for aged filters. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

ENDF/B-VIII.0: the 8. major release of the ENDF/B library containing CIELO-project evaluations, new standards and thermal scattering data - 25580

The ENDF/B-VIII.0 evaluated nuclear reaction data library was released on February 2, 2018. ENDF/B-VIII.0 incorporates many improvements including the new IAEA standards, a nearly completely new thermal neutron scattering sublibrary and the CIELO project evaluations for neutron reactions on {sup 16}O, {sup 56}Fe, {sup 235}U, {sup 238}U and {sup 239}Pu. These evaluations are a direct result of improvements in theory and simulation and benefit from recent experimental data obtained in the U.S. and Europe. Notable other advances include updated evaluated data for light nuclei, structural materials, actinides and charged-particle reactions, and specific updates to fission energy release, prompt fission neutron and γ-ray spectra. ENDF/B-VIII.0 has undergone substantial testing including a wide range of criticality, reaction rate, and shielding benchmarks. Our integral validation demonstrates that performance of the library is a noticeable improvement over the previous ENDF/B-VII.1 library. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Impact of new prompt fission neutron spectrum evaluations and the associated cross-correlations on critical assemblies using MCNP6 - 14385

Two recent re-evaluations of the neutron-induced prompt fission neutron spectrum (PFNS) of uranium and plutonium actinides have included some cross-correlated uncertainties that have not been released in a new nuclear data library. The first re-evaluation included cross-isotope correlations of the PFNS within each of the uranium and plutonium suites of actinides below the second-chance fission threshold. The second, more recent re-evaluation includes incident energy-dependent correlations of the {sup 239}Pu(n,f) PFNS. Both of these new evaluations and their cross-correlations, given the importance of these actinide quantities and because the impact of the incident energy-dependent correlations has never been studied previously, could have an impact on a variety of criticality safety applications. For example, the ke uncertainty due to the uranium PFNS uncertainties in the Big Ten critical assembly is underpredicted by ∼10% when the cross-isotope correlations in the uranium PFNS are ignored. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluated {sup 182,183,184,186}W neutron cross sections and covariances in the resolved resonance region - 14617

Oak Ridge National Laboratory (ORNL) has recently completed the resonance parameter evaluation of four tungsten isotopes, i.e., {sup 182,183,184,186}W, in the neutron energy range of thermal up to several keV. This nuclear data work was performed with support from the US Nuclear Criticality Safety Program (NCSP) in an effort to provide improved tungsten cross section and covariance data for criticality safety analyses. The evaluation methodology uses the Reich-Moore approximation of the R-matrix formalism of the code SAMMY to fit high-resolution measurements performed in 2010 and 2012 at the Geel linear accelerator facility (GELINA), as well as other experimental data sets on natural tungsten available in the EXFOR library. In the analyzed energy range, this work nearly doubles the resolved resonance region (RRR) present in the latest US nuclear data library ENDF/B-VII.1. In view of the interest in tungsten for distinct types of nuclear applications and the relatively homogeneous distribution of the isotopic tungsten - namely, {sup 182}W(26.5%), {sup 183}W(14.31%), {sup 184}W(30.64%), and {sup 186}W(28.43%) - the completion of these four evaluations represents a significant contribution to the improvement of the ENDF library. This paper presents an overview of the evaluated resonance parameters and related covariances for total and capture cross sections on the four tungsten isotopes. (authors)