Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXPECTATION VALUES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Superconductivity in La and Y hydrides: Remaining questions to experiment and theory

Recent reports of the superconductivity in hydrides of two different families (covalent lattice, as in SH3 and clathrate-type H-cages containing La and Y atoms, as in LaH10 and YH6) have revealed new families of high-Tc materials with Tc’s near room temperature values. These findings confirm earlier expectations that hydrides may have very high Tc’s due to the fact that light H atoms have very high vibrational frequencies, leading to high Tc values within the conventional Bardeen–Cooper–Schrieffer phonon mechanism of superconductivity. However, as is pointed out by Ashcroft, it is important to have the metallic hydrogen “alloyed” with the elements added to it. This concept of a metallic alloy containing a high concentration of metal-like hydrogen atoms has been instrumental in finding new high-Tc superhydrides. These new superhydride “room-temperature” superconductors are stabilized only at very high pressures above 100 GPa, making the experimental search for their superconducting properties very difficult. We will review the current experimental and theoretical results for LaH10−x and YH6−x superhydrides.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TableCalculator: a Transparent Public Tool to Replicate US NRC LLW Classification Table Calculations - 19395

Classification of Low-Level Waste (LLW) as Class A, B, C, or Greater than Class C (GTCC) is based on tables provided in Section 61.55 of Title 10 of the Code of Federal Regulations (CFR). Those tables were developed from model projections of dose to an inadvertent intruder in agricultural and construction scenarios at different times after closure of a LLW land disposal site. The calculations were performed with two FORTRAN codes, which are documented in US NRC guidance documents published in the early 1980's. Although the equations and parameter values used in the codes are publicly available, no modern, user-friendly implementation of the codes is known to US NRC staff. Because Very Low-Level Waste (VLLW) and GTCC waste disposal are related to the low end and high end of the existing LLW waste classifications, respectively, recent interest in options for disposal of VLLW and GTCC waste have generated public interest in the original assumptions made during the development of the LLW classification tables. Certain stakeholder analyses have recommended alternatives to the existing LLW concentration limits by calculating a projected intruder dose under different conditions than were evaluated in the original development of 10 CFR Part 61 (e.g., using more modern dosimetry or assuming deeper disposal) and comparing the radionuclide concentrations that result in a projected annual dose of 5 milliSieverts (mSv) (500 millirem (mrem)) total effective dose equivalent (TEDE) to the concentrations in the waste classification tables. However, beginning with the 10 CFR Part 61 LLW classification limits and modifying only one or two assumptions to generate a proposed concentration limit could lead to misleading results without a thorough analysis of whether other assumptions made in the original development of the waste classification tables remain valid. In particular, the US NRC made adjustments to the 10 CFR 61.55 table values during the rulemaking process based on qualitative considerations. Those adjustments mean that many of the values in the final tables cannot simply be assumed to quantitatively represent a 5 mSv (500 mrem) projected inadvertent intruder dose without an assessment of whether the technical bases used to develop the adjustments are applicable to the new analysis. Furthermore, the waste classification limits were based on the limiting critical organ dose rather than a TEDE. Therefore, any calculation based on the assumption that the waste classification limits correspond to 5 mSv (500 mrem) TEDE could benefit from consideration of how differences in exposure pathways could affect the limiting critical organ dose differently from the TEDE. To facilitate a more comprehensive understanding of the calculations used to develop the waste classification tables, the US NRC staff has developed a user-friendly tool to replicate the original calculations. Results were verified against output from the FORTRAN codes and the classification table values. The tool, TableCalculator, is expected to be made publicly available and will allow the user to trace the original calculations and to observe the effects of changes in disposal assumptions and other parameter values. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Buckling in polymer monolayers: Molecular-weight dependence

We present systematic investigations of buckling in Langmuir monolayers of polyvinyl acetate formed at the air-water interface. On compression the polymer monolayers are converted to a continuous membrane with a thickness of {approx}2-3 nm of well-defined periodicity, {lambda}{sub b}. Above a certain surface concentration the membrane undergoes a morphological transition buckling, leading to the formation of striped patterns. The periodicity seems to depend on molecular weight as per the predictions of the gravity-bending buckling formalism of Milner et al. for fluidlike films on water. However anomalously low values of bending rigidity and Young's modulus are obtained using this formalism. Hence we have considered an alternative model of buckling-based solidlike films on viscoelastic substrates. The values of bending rigidity and Young's modulus obtained by this method, although lower than expected, are closer to the bulk values. Remarkably, no buckling is found to occur above a certain molecular weight. We have tried to explain the observed molecular-weight dependence in terms of the variation in isothermal compressive modulus of the monolayers with surface concentration as well as provided possible explanations for the obtained low values of mechanical properties similar to that observed for ultrathin polymer films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DO WE REALLY KNOW THE DUST? SYSTEMATICS AND UNCERTAINTIES OF THE MID-INFRARED SPECTRAL ANALYSIS METHODS

The spectral region around 10 {mu}m, showing prominent emission bands from various dust species is commonly used for the evaluation of the chemical composition of protoplanetary dust. Different methods of analysis have been proposed for this purpose, but so far, no comparative test has been performed to test the validity of their assumptions. In this paper, we evaluate how good the various methods are in deriving the chemical composition of dust grains from infrared spectroscopy. Synthetic spectra of disk models with different geometries and central sources were calculated, using a two-dimensional radiative transfer code. These spectra were then fitted in a blind test by four spectral decomposition methods. We studied the effect of disk structure (flared versus flat), inclination angle, size of an inner disk hole, and stellar luminosity on the fitted chemical composition. Our results show that the dust parameters obtained by all methods deviate systematically from the input data of the synthetic spectra. The dust composition fitted by the new two-layer temperature distribution method, described in this paper, differs the least from the input dust composition and the results show the weakest systematic effects. The reason for the deviations of the results given by the previously used methods lies in their simplifying assumptions. Due to the radial extent of the 10 {mu}m emitting region there is dust at different temperatures contributing to the flux in the silicate feature. Therefore, the assumption of a single averaged grain temperature can be a strong limitation of the previously used methods. The continuum below the feature can consist of multiple components (e.g., star, inner rim, and disk midplane), which cannot simply be described by a Planck function at a single temperature. In addition, the optically thin emission of 'featureless' grains (e.g., carbon in the considered wavelength range) produces a degeneracy in the models with the optically thick emission of the disk. The effect of different noise levels on the results has also been tested. We find that for a signal-to-noise ratio (S/N) of 100 one can expect an absolute uncertainty in the value of the crystallinity of about 11% using ground-based observations (8-13 {mu}m). For space-based observations (7-17 {mu}m) the expected uncertainty is about 5% for the same S/N value. Moreover, the average value of the estimated crystallinity increases toward lower S/N in general. On the basis of our results, we propose a recipe for the analysis and interpretation of dust spectroscopy data in the mid-infrared which should be especially valuable for analyzing Spitzer spectroscopy data and ground-based infrared spectroscopy data in the 10 {mu}m window.

99 GENERAL AND MISCELLANEOUS↗

Value of Information in Fuel Cycle Decision-making

Transitions between nuclear fuel cycles with uncertain key parameters (e.g., SNF and HLW disposal costs, fast reactor capital costs) have been examined using a decision-making under uncertainty methodology. The methodology explicitly incorporates uncertainties in key parameters into the decision-making process by constructing a stochastic model and embedding uncertainties as bifurcations in the decision-tree. The framework of this methodology allows for interpretation using a real options valuation or game theoretic approach, reviewed in. The work presented here extends the decision-making under uncertainty framework to calculate the value of information, which may be used to inform a game against nature. These games against nature have been applied to resource allocation problems, where scarce resources are allocated to maximize expected payoffs. More broadly, the value of developing alternative technologies may be considered under the same framework, where an investment portfolio for technology deployment may be developed. Here, the value of information is taken as the value of reducing uncertainty in key parameters, and these values may be substituted for the traditional payoff matrix when considering allocating scarce resources. Games against nature may provide a unique perspective on R and D funding decisions when considering transitions between nuclear fuel cycles. By determining the value of reducing uncertainties (of gaining information on probability distributions) scarce resources may be allocated in such a way to maximize their utility. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

INTERFERENCE DETECTION IN GAUSSIAN NOISE

Interference detection in Gaussian noise is proposed. It can be applied for easy detection and editing of interference lines in radio spectral line observations. One does not need to know the position of occurrence or keep track of interference in the band. By using statistical properties of N-channel Gaussian noise it is possible to differentiate interference from normal Gaussian noise. These statistical properties are three quantities which are calculated on the subject spectrum. The first is the expected absolute maximum from the mean level across the spectrum. The second is the expected absolute difference maximum (array of adjacent differences of channel values taken across the spectrum), and the third is the expected absolute added difference maximum. For N-channel Gaussian noise, these quantities have a well-defined value. Any deviation across the spectrum that violates an upper limit formed by these expected maxima is attributed to interference. Results obtained on real data by applying this technique have been displayed.

97 MATHEMATICS AND COMPUTING↗

Crossover from first-order to second-order phase transitions and magnetocaloric effect in La{sub 0.7}Ca{sub 0.3}Mn{sub 0.91}Ni{sub 0.09}O{sub 3}

We have prepared La{sub 0.7}Ca{sub 0.3}Mn{sub 0.91}Ni{sub 0.09}O{sub 3} and then studied its critical behavior and magnetocaloric effect. Analyzing temperature and field dependences of magnetization around the ferromagnetic-paramagnetic transition reveals the sample undergoing the second-order magnetic phase transition with the critical parameters T{sub C} ≈ 199.4 K, β = 0.171 ± 0.006, and γ = 0.976 ± 0.012. A considerable difference of these critical exponents compared with those expected for the standard models is due to the sample exhibiting the crossover property (tricriticality); its exponent values are more close to those expected for the tricritical mean-field theory with β = 0.25 and γ = 1. Under the field 40 kOe, the maximum magnetic entropy change (−ΔS{sub max}) around T{sub C} is about 7.1 J·kg{sup −1}·K{sup −1}, corresponding to a refrigerant capacity RC ≈ 170 J/kg. Particularly, its magnetic-field dependence obeys a power law |ΔS{sub max}| ∝ H{sup n}, where n = 0.55 is quite far from the value calculated from the relation n = 1 + (β − 1)/(β + γ)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Technical Report: Reference photon dosimetry data for Varian accelerators based on IROC-Houston site visit data

Purpose: Accurate data regarding linear accelerator (Linac) radiation characteristics are important for treatment planning system modeling as well as regular quality assurance of the machine. The Imaging and Radiation Oncology Core-Houston (IROC-H) has measured the dosimetric characteristics of numerous machines through their on-site dosimetry review protocols. Photon data are presented and can be used as a secondary check of acquired values, as a means to verify commissioning a new machine, or in preparation for an IROC-H site visit. Methods: Photon data from IROC-H on-site reviews from 2000 to 2014 were compiled and analyzed. Specifically, data from approximately 500 Varian machines were analyzed. Each dataset consisted of point measurements of several dosimetric parameters at various locations in a water phantom to assess the percentage depth dose, jaw output factors, multileaf collimator small field output factors, off-axis factors, and wedge factors. The data were analyzed by energy and parameter, with similarly performing machine models being assimilated into classes. Common statistical metrics are presented for each machine class. Measurement data were compared against other reference data where applicable. Results: Distributions of the parameter data were shown to be robust and derive from a student’s t distribution. Based on statistical and clinical criteria, all machine models were able to be classified into two or three classes for each energy, except for 6 MV for which there were eight classes. Quantitative analysis of the measurements for 6, 10, 15, and 18 MV photon beams is presented for each parameter; supplementary material has also been made available which contains further statistical information. Conclusions: IROC-H has collected numerous data on Varian Linacs and the results of photon measurements from the past 15 years are presented. The data can be used as a comparison check of a physicist’s acquired values. Acquired values that are well outside the expected distribution should be verified by the physicist to identify whether the measurements are valid. Comparison of values to this reference data provides a redundant check to help prevent gross dosimetric treatment errors.

60 APPLIED LIFE SCIENCES↗

Evaluating the effect of varying flux group endpoints on reaction rates of 238 U

This acts as a short note on the effects of varying the value of the endpoints of the thermal, epithermal, and fast flux groups. As expected, varying these endpoints can alter the value of the cross-section for a given nuclide. This effect is quantified in this note for an important nuclide in reactor simulations, 238 U. Uranium-238 is responsible for the production of Plutonium in most reactors, making it critical to understand all of the 238 U capture modes leading to Plutonium. We explicitly quantify the reaction rates for 238 U that are altered when we use a given research reactor flux and vary the endpoint definitions of said flux as well as the reactor position.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Oak Ridge National Laboratory Technical Input for the Nuclear Regulatory Commission Review of the 2017 Edition of ASME Section III, Division 5, ‘High Temperature Reactors’

To assist the Nuclear Regulatory Commission in its decision making on endorsement of the American Society for Mechanical Engineers Boiler and Pressure Vessel Code Section III, Division 5 (2017 Edition) for development of advanced non-light water reactors, the following Division 5 portions were reviewed: Article HBB-2000 Material; Article HCB-2000 Material; Article HGB-2000 Material; Mandatory Appendix HBB-I-14 Tables and Figures; and, Nonmandatory Appendix HBB-U Guidelines for Restricted Material Specifications to Improve Performance in Certain Service Applications. In addition to the 2017 Edition, the same parts of the 2019 Edition have also been reviewed as indicated in various sections of the report. This review was conducted by a collaboration of national laboratory and private sector participants with significant industrial experience, including some heavy lifting and deep diving from Clarus Consulting, LLC., all intended to achieve an objective, independent, and practical perspective. The report provides recommendations, descriptions of the evaluation methods, and the source references for the data used. To build confidence required for endorsement of the Code, this review was conducted as a verification and validation of the above Code contents. The objective of verification is to ensure that the Code is free of error – direct or implied; contains the information needed for its use, including proper coverage of the Code-specified materials for the intended application, and completeness and adequacy of references to other portions of the Code. The objective of validation is to authenticate that the Code tabulations and graphs represent design inputs consistent with what are determined using rules and methods specified by the Code. The authentication process used data that were assembled and/or generated independent of Code development, while the methods of analysis followed Code-specified methods where appropriate. The designated portions for this review cover the five alloys codified for high temperature reactor applications in Division 5, i.e. 316 SS, 304 SS, 800H, 2¼Cr-1Mo, and 9Cr-1Mo-V, regarding their general requirements, permitted specifications and design stress intensity values for pressure-retaining applications, deterioration in service, fatigue acceptance test, permissible weld materials, tensile and yield strength, expected minimum stress-to-rupture values (including for Alloy 718), weld stress rupture factors, permissible materials for bolting use, and restricted specifications in certain service applications. Additionally, stress intensity values for bolting materials including 316 SS, 304 SS and alloy 718 were reviewed. Analysis and discussion are also provided on contents outside of these designated Code portions where it was deemed relevant and necessary to develop a technically sound understanding of issues relating to the designated portions. Due to unavailability of sufficient test data on welds during the review period, the weld stress rupture factors in Tables HBB-I-10.14A to E, which cover a total of ten tables for the five alloys welded with twenty-eight different weld metals (some with similar properties), have been deferred to a future review effort. The review identified mainly two types of issues. The first type includes instances where the Code is found factually incomplete or incorrect, such as obsolete materials specifications listings, missing tabulation of stresses for bolting. Changes to the Code are recommended in these cases. The second type of issue includes instances where the Code tabulations and graphs are found to be less conservative than the review analysis results. In these cases, recommendations are made for further review and consideration where the difference in conservatism exceeds 10%, which is our threshold for questioning technical adequacy, meriting a risk assessment by the Nuclear Regulatory Commission and/or reactor designers. It is noted that this effort has been executed using all available data and established methods of analysis, including methods and criteria specified and used by the Code. As such, the findings that are presented in quantitative detail, in a format for convenient comparison with the Code, and with identification of where further review is recommended, should provide a sound technical basis for decisions about quantifying the implications of the reduced design margins and technical adequacy/inadequacy to form a basis for conditioning specific Code tabulation values on endorsement. Recommendations for specific changes to the Code, however, entail design conservatism considerations beyond the scope of this review effort, and are not made in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-J-210: Characterizing Tissue Equivalent Materials for the Development of a Dual MRI-CT Heterogeneous Anthropomorphic Phantom Designed Specifically for MRI Guided Radiotherapy Systems

Purpose: MRI guided radiotherapy (MRIgRT) is an emerging technology which will eventually require a proficient quality auditing system. Due to different principles in which MR and CT acquire images, there is a need for a multi-imaging-modality, end-to-end QA phantom for MRIgRT. The purpose of this study is to identify lung, soft tissue, and tumor equivalent substitutes that share similar human-like CT and MR properties (i.e. Hounsfield units and relaxation times). Methods: Materials of interested such as common CT QA phantom materials, and other proprietary gels/silicones from Polytek, SmoothOn, and CompositeOne were first scanned on a GE 1.5T Signa HDxT MR. Materials that could be seen on both T1-weighted and T2-weighted images were then scanned on a GE Lightspeed RT16 CT simulator and a GE Discovery 750HD CT scanner and their HU values were then measured. The materials with matching HU values of lung (−500 to −700HU), muscle (+40HU) and soft tissue (+100 to +300HU) were further scanned on GE 1.5T Signa HDx to measure their T1 and T2 relaxation times from varying parameters of TI and TE. Results: Materials that could be visualized on T1-weighted and T2-weighted images from a 1.5T MR unit and had an appropriate average CT number, −650, −685, 46,169, and 168 HUs were: compressed cork saturated with water, Polytek Platsil™ Gel-00 combined with mini styrofoam balls, radiotherapy bolus material, SmoothOn Dragon-Skin™ and SmoothOn Ecoflex™, respectively. Conclusion: Post processing analysis is currently being performed to accurately map T1 and T2 values for each material tested. From previous MR visualization and CT examinations it is expected that Dragon-Skin™, Ecoflex™ and bolus will have values consistent with tissue and tumor substitutes. We also expect compressed cork statured with water, and Polytek™-styrofoam combination to have approximate T1 and T2 values suitable for lung-equivalent materials.

60 APPLIED LIFE SCIENCES↗

( NuSTAR NuSTAR) observations of WISE J1036+0449, a galaxy at z ∼ 1 obscured by hot dust

Hot dust-obscured galaxies (hot DOGs), selected from Wide-Field Infrared Survey Explorer’s all-sky infrared survey, host some of the most powerful active galactic nuclei known and may represent an important stage in the evolution of galaxies. Most known hot DOGs are located at z>1.5, due in part to a strong bias against identifying them at lower redshift related to the selection criteria. We present a new selection method that identifies 153 hot DOG candidates at z∼1, where they are significantly brighter and easier to study. We validate this approach by measuring a redshift z = 1.009 and finding a spectral energy distribution similar to that of higher-redshift hot DOGs for one of these objects, WISE J1036+0449 (L{sub Bol}≃8×10{sup 46} erg s{sup −1}). We find evidence of a broadened component in Mg ii, which would imply a black hole mass of M{sub BH}≃2×10{sup 8} M{sub ⊙} and an Eddington ratio of λ{sub Edd}≃2.7. WISE J1036+0449 is the first hot DOG detected by the Nuclear Spectroscopic Telescope Array, and observations show that the source is heavily obscured, with a column density of N{sub H}≃(2--15)×10{sup 23} cm{sup −2}. The source has an intrinsic 2–10 keV luminosity of ∼6×10{sup 44} erg s{sup −1}, a value significantly lower than that expected from the mid-infrared/X-ray correlation. We also find that other hot DOGs observed by X-ray facilities show a similar deficiency of X-ray flux. We discuss the origin of the X-ray weakness and the absorption properties of hot DOGs. Hot DOGs at z≲1 could be excellent laboratories to probe the characteristics of the accretion flow and of the X-ray emitting plasma at extreme values of the Eddington ratio.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of the prescription dose for biradionuclide permanent prostate brachytherapy

A model based on the linear quadratic model that has been corrected for repopulation, sublethal cell damage repair, and RBE effect has been used to determine the prescription dose for prostate permanent brachytherapy using seeds loaded with a mixture of {sup 103}Pd and {sup 125}I or a mixture of {sup 103}Pd and {sup 131}Cs. The prescription dose was determined by comparing the tumor cell survival fractions between the considered biradionuclide seed implant and one monoradionuclide seed implant chosen from {sup 103}Pd, {sup 125}I, and {sup 131}Cs. Prostate edema is included in the model. The influence of the value of the radiobiological parameters and RBE were also investigated. Two mixtures of radionuclides were considered: {sup 103}Pd{sub 0.75}-{sup 125}I{sub 0.25} and {sup 103}Pd{sub 0.25}-{sup 131}Cs{sub 0.75}, where the subscripts indicate the fractions of total initial internal activity in the biradionuclide seed. These fractions were selected in order to obtain a dose distribution that lies between that of {sup 103}Pd and {sup 125}I/{sup 131}Cs. As expected, the computed prescription dose values are dependent on the model parameters (edema half-life and magnitude, radiobiogical parameters, and RBE). The radionuclide used as a benchmark also has a strong impact on the derived prescribed dose. The large uncertainties in the radiobiological parameters and RBE values produce big errors in the computed prescribed dose. Averaged over the range of all the parameters and depending on the radionuclide used as a benchmark (in subscript), the derived prescription dose for the first mixture (PdI) would be: D{sub Pd}{sup PdI}=142{sub -16}{sup +15} Gy and D{sub I}{sup PdI}=142{sub -8}{sup +6} Gy; and D{sub Pd}{sup PdCs}=128{sub -13}{sup +13} Gy and D{sub Cs}{sup PdCs}=115{sub -7}{sup +6} Gy for the PdCs mixture. The uncertainties could be reduced if the radiobiological parameters and RBE value were known more accurately. However, as edema characteristics are patient dependent and can be obtained only after the treatment, an unpredictable error is unavoidable.

60 APPLIED LIFE SCIENCES↗

AGC-4 As-Run Uncertainty Analysis

The concept of measuring neutron flux (or fluence rate) with activation foils has existed since the late 1940s and is a well-used methodology. Activation foils are selected for their unique isotopic cross sections that create reaction products with desirable properties: relatively simple radioactive decay scheme, measurable quantities of gamma-rays or betas, and half-lives appropriate for the irradiation and decay durations of the experiment. The activation materials, deemed flux wires, fluence wires, dosimeters, or flux foils, are fabricated to have a mass appropriate for the irradiation as well so the measurement using a radiation detector following the irradiation is sufficient but not overwhelming in terms of total activity. Activation measurement results are expressed in terms of reaction rate, which can then be used to “adjust” the neutron spectrum. The Advanced Graphite Creep (AGC)-4 experiment contained 26 flux wire packages, each containing an iron and a niobium wire inside a vanadium capsule. For all stackup positions, the value of fast to thermal neutrons is higher than expected, but the total neutron fluence is near the predicted value of ~2 x 1022 n/cm2. As compared to the predicted neutron spectrum, there are four takeaways in the results as compared to the predicted ATR irradiation: 1) Additional fast (fission) neutrons present, 2) Spectrum hardening due to temperature, 3) Spectrum hardening due to container attenuation, 4) Total neutron fluence is close to predicted values. Since the neutron energy spectrum is a key parameter when attributing neutron damage in materials, the adjusted energy-dependent spectrum and the total neutron fluence results from the dosimeters can be incorporated for future calculations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simultaneous analysis of the Ballik-Ramsay and Phillips systems of C{sub 2} and observation of forbidden transitions between singlet and triplet states

6229 lines of the Ballik-Ramsay system (b{sup 3}Σ{sub g}{sup −}–a{sup 3}Π{sub u}) and the Phillips system (A{sup 1}Π{sub u}–X{sup 1}Σ{sub g}{sup +}) of C{sub 2} up to v = 8 and J = 76, which were taken from the literature or assigned in the present work, were analyzed simultaneously by least-squares fitting with 82 Dunham-like molecular parameters and spin-orbit interaction constants between the b{sup 3}Σ{sub g}{sup −} and X{sup 1}Σ{sub g}{sup +} states with a standard deviation of 0.0037 cm{sup −1} for the whole data set. As a result of the deperturbation analysis, the spin-orbit interaction constant A{sub bX} was determined as 6.333(7) cm{sup −1} and the energy difference between the X{sup 1}Σ{sub g}{sup +} and a{sup 3}Π{sub u} states was determined as 720.008(2) cm{sup −1} for the potential minima or 613.650(3) cm{sup −1} for the v = 0 levels with Merer and Brown’s N{sup 2} Hamiltonian for {sup 3}Π states, which is about 3.3 cm{sup −1} larger than the previously determined value. Due to this sizable change, a new energy-level crossing was found at J = 2 for v = 3 (F{sub 1}) of b{sup 3}Σ{sub g}{sup −} state and v = 6 of X{sup 1}Σ{sub g}{sup +} state, where the strong interaction causes a nearly complete mixing of the wave functions of the b{sup 3}Σ{sub g}{sup −} and X{sup 1}Σ{sub g}{sup +} states and the forbidden transitions become observable. Using the predictions of our deperturbation analysis, we were able to identify 16 forbidden transitions between the singlet and triplet states at the predicted frequencies with the expected intensities, which verifies our value for the energy difference between the X{sup 1}Σ{sub g}{sup +} and a{sup 3}Π{sub u} states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhancement of Er optical efficiency through bismuth sensitization in yttrium oxide

The process of energy transfer (ET) between optically active ions has been widely studied to improve the optical efficiency of a system for different applications, from lighting and photovoltaics to silicon microphotonics. In this work, we report the influence of Bi on the Er optical emission in erbium-yttrium oxide thin films synthesized by magnetron co-sputtering. We demonstrate that this host permits to well dissolve Er and Bi ions, avoiding their clustering, and thus to stabilize the optically active Er{sup 3+} and Bi{sup 3+} valence states. In addition, we establish the ET occurrence from Bi{sup 3+} to Er{sup 3+} by the observed Bi{sup 3+} PL emission decrease and the simultaneous Er{sup 3+} photoluminescence (PL) emission increase. This was further confirmed by the coincidence of the Er{sup 3+} and Bi{sup 3+} excitation bands, analyzed by PL excitation spectroscopy. By increasing the Bi content of two orders of magnitude inside the host, though the occurrence of Bi-Bi interactions becomes deleterious for Bi{sup 3+} optical efficiency, the ET process between Bi{sup 3+} and Er{sup 3+} is still prevalent. We estimate ET efficiency of 70% for the optimized Bi:Er ratio equal to 1:3. Moreover, we have demonstrated to enhance the Er{sup 3+} effective excitation cross section by more than three orders of magnitude with respect to the direct one, estimating a value of 5.3 × 10{sup −18} cm{sup 2}, similar to the expected Bi{sup 3+} excitation cross section. This value is one of the highest obtained for Er in Si compatible hosts. These results make this material very promising as an efficient emitter for Si-compatible photonics devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Property Measurements of NaCl-UCl 3 and LiF-NaF-KF Molten Salts Doped with Surrogate Fission Products

Knowing thermophysical and thermochemical property values of salts over the expected range of operating temperatures is essential to modeling and simulation efforts that support the commercialization of molten salt reactor (MSR) technologies. Salt properties being measured at Argonne include thermal transitions, phase behavior, heat capacity, density, surface tension, volumetric thermal expansion, thermal diffusivity, thermal conductivity, and viscosity. The properties of several salts of interest including NaCl-UCl 3 and LiF-NaF-KF (FLiNaK) have been measured at Argonne and reported previously. These property measurements are suitable for use in evaluating reactor performance during startup and the early operating life of the reactor. The physical and chemical behavior of the fuel salt is altered by the buildup of fission products and the resulting changes in heat transfer and other properties must be understood by reactor developers. This report summarizes melting behavior, heat capacity, and thermal diffusivity values that were measured for mixtures of FLiNaK and NaCl-UCl 3 salts that have been doped with surrogate fission products. Additional heat capacity measurements were also performed on a separate mixture of FLiNaK without dopants. Measured properties are suitable for incorporation into the Molten Salt Thermal Properties Database–Thermochemical (MSTDB–TC) and the Molten Salt Thermal Properties Database–Thermophysical (MSTDB–TP) to support the development of MSRs. Salts were prepared by doping eutectic mixtures of NaCl-UCl 3 and FLiNaK with surrogate fission products. These salts were prepared for use in salt spill experiments being performed at Argonne and were subsequently used for thermal property measurements. Thermal transitions and heat capacities were measured by using differential scanning calorimetry (DSC) and thermal diffusivity was measured by using laser flash analysis (LFA) at temperatures spanning the typical MSR operating range. The measured property values of the doped salts were compared to measured property values of salts without fission products to quantify the effects of the doped fission products.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗