WE-B-BRC-01: Current Methodologies in Risk Assessment

Prospective quality management techniques, long used by engineering and industry, have become a growing aspect of efforts to improve quality management and safety in healthcare. These techniques are of particular interest to medical physics as scope and complexity of clinical practice continue to grow, thus making the prescriptive methods we have used harder to apply and potentially less effective for our interconnected and highly complex healthcare enterprise, especially in imaging and radiation oncology. An essential part of most prospective methods is the need to assess the various risks associated with problems, failures, errors, and design flaws in our systems. We therefore begin with an overview of risk assessment methodologies used in healthcare and industry and discuss their strengths and weaknesses. The rationale for use of process mapping, failure modes and effects analysis (FMEA) and fault tree analysis (FTA) by TG-100 will be described, as well as suggestions for the way forward. This is followed by discussion of radiation oncology specific risk assessment strategies and issues, including the TG-100 effort to evaluate IMRT and other ways to think about risk in the context of radiotherapy. Incident learning systems, local as well as the ASTRO/AAPM ROILS system, can also be useful in the risk assessment process. Finally, risk in the context of medical imaging will be discussed. Radiation (and other) safety considerations, as well as lack of quality and certainty all contribute to the potential risks associated with suboptimal imaging. The goal of this session is to summarize a wide variety of risk analysis methods and issues to give the medical physicist access to tools which can better define risks (and their importance) which we work to mitigate with both prescriptive and prospective risk-based quality management methods. Learning Objectives: Description of risk assessment methodologies used in healthcare and industry Discussion of radiation oncology-specific risk assessment strategies and issues Evaluation of risk in the context of medical imaging and image quality E. Samei: Research grants from Siemens and GE.

60 APPLIED LIFE SCIENCES↗

WE-B-BRC-02: Risk Analysis and Incident Learning

Prospective quality management techniques, long used by engineering and industry, have become a growing aspect of efforts to improve quality management and safety in healthcare. These techniques are of particular interest to medical physics as scope and complexity of clinical practice continue to grow, thus making the prescriptive methods we have used harder to apply and potentially less effective for our interconnected and highly complex healthcare enterprise, especially in imaging and radiation oncology. An essential part of most prospective methods is the need to assess the various risks associated with problems, failures, errors, and design flaws in our systems. We therefore begin with an overview of risk assessment methodologies used in healthcare and industry and discuss their strengths and weaknesses. The rationale for use of process mapping, failure modes and effects analysis (FMEA) and fault tree analysis (FTA) by TG-100 will be described, as well as suggestions for the way forward. This is followed by discussion of radiation oncology specific risk assessment strategies and issues, including the TG-100 effort to evaluate IMRT and other ways to think about risk in the context of radiotherapy. Incident learning systems, local as well as the ASTRO/AAPM ROILS system, can also be useful in the risk assessment process. Finally, risk in the context of medical imaging will be discussed. Radiation (and other) safety considerations, as well as lack of quality and certainty all contribute to the potential risks associated with suboptimal imaging. The goal of this session is to summarize a wide variety of risk analysis methods and issues to give the medical physicist access to tools which can better define risks (and their importance) which we work to mitigate with both prescriptive and prospective risk-based quality management methods. Learning Objectives: Description of risk assessment methodologies used in healthcare and industry Discussion of radiation oncology-specific risk assessment strategies and issues Evaluation of risk in the context of medical imaging and image quality E. Samei: Research grants from Siemens and GE.

60 APPLIED LIFE SCIENCES↗

WE-B-BRC-03: Risk in the Context of Medical Imaging

Prospective quality management techniques, long used by engineering and industry, have become a growing aspect of efforts to improve quality management and safety in healthcare. These techniques are of particular interest to medical physics as scope and complexity of clinical practice continue to grow, thus making the prescriptive methods we have used harder to apply and potentially less effective for our interconnected and highly complex healthcare enterprise, especially in imaging and radiation oncology. An essential part of most prospective methods is the need to assess the various risks associated with problems, failures, errors, and design flaws in our systems. We therefore begin with an overview of risk assessment methodologies used in healthcare and industry and discuss their strengths and weaknesses. The rationale for use of process mapping, failure modes and effects analysis (FMEA) and fault tree analysis (FTA) by TG-100 will be described, as well as suggestions for the way forward. This is followed by discussion of radiation oncology specific risk assessment strategies and issues, including the TG-100 effort to evaluate IMRT and other ways to think about risk in the context of radiotherapy. Incident learning systems, local as well as the ASTRO/AAPM ROILS system, can also be useful in the risk assessment process. Finally, risk in the context of medical imaging will be discussed. Radiation (and other) safety considerations, as well as lack of quality and certainty all contribute to the potential risks associated with suboptimal imaging. The goal of this session is to summarize a wide variety of risk analysis methods and issues to give the medical physicist access to tools which can better define risks (and their importance) which we work to mitigate with both prescriptive and prospective risk-based quality management methods. Learning Objectives: Description of risk assessment methodologies used in healthcare and industry Discussion of radiation oncology-specific risk assessment strategies and issues Evaluation of risk in the context of medical imaging and image quality E. Samei: Research grants from Siemens and GE.

60 APPLIED LIFE SCIENCES↗

WE-H-BRC-04: Implement Lean Methodology to Make Our Current Process of CT Simulation to Treatment More Efficient

Purpose: Our goal is to implement lean methodology to make our current process of CT simulation to treatment more efficient. Methods: In this study, we implemented lean methodology and tools and employed flowchart in excel for process-mapping. We formed a group of physicians, physicists, dosimetrists, therapists and a clinical physics assistant and huddled bi-weekly to map current value streams. We performed GEMBA walks and observed current processes from scheduling patient CT Simulations to treatment plan approval. From this, the entire workflow was categorized into processes, sub-processes, and tasks. For each process we gathered data on touch time, first time quality, undesirable effects (UDEs), and wait-times from relevant members of each task. UDEs were binned per frequency of their occurrence. We huddled to map future state and to find solutions to high frequency UDEs. We implemented visual controls, hard stops, and documented issues found during chart checks prior to treatment plan approval. Results: We have identified approximately 64 UDEs in our current workflow that could cause delays, re-work, compromise the quality and safety of patient treatments, or cause wait times between 1 – 6 days. While some UDEs are unavoidable, such as re-planning due to patient weight loss, eliminating avoidable UDEs is our goal. In 2015, we found 399 issues with patient treatment plans, of which 261, 95 and 43 were low, medium and high severity, respectively. We also mapped patient-specific QA processes for IMRT/Rapid Arc and SRS/SBRT, involving 10 and 18 steps, respectively. From these, 13 UDEs were found and 5 were addressed that solved 20% of issues. Conclusion: We have successfully implemented lean methodology and tools. We are further mapping treatment site specific workflows to identify bottlenecks, potential breakdowns and personnel allocation and employ tools like failure mode effects analysis to mitigate risk factors to make this process efficient.

60 APPLIED LIFE SCIENCES↗

Electrochemical Response of Alkaline Batteries Subject to Quasi-Static and Dynamic Loading

We report electrochemical changes were successfully monitored through the coupling of external loading, electrochemical impedance spectroscopy (EIS), and distribution of relaxation times (DRT) analysis. The development of the testing methods allows for detailed observation of changes due to mechanical loading and distinguishes responses between different cell geometries. Comparison of the force vs displacement, voltage vs displacement, and distribution of relaxation times plots to the different cell geometries display failure modes specific to geometry as well as the impact of different loading profiles. Numerical modeling confirmed the movement within individual cells and predicted locations with the most deformation based on the external loading condition applied. The results gathered from combining mechanical loading, electrochemical response, and numerical modeling, yield a viable approach to establishing an improved understanding of the effects of mechanical loading on the electrochemical response of multiple battery geometries and the methods herein may be extensible to additional battery chemistries.

25 ENERGY STORAGE↗

Impact of Electrolyte Additives on the Lifetime of High Voltage NMC Lithium-Ion Pouch Cells

This work involves improving the lifetime of lithium-ion cells during high voltage cycling using electrolyte additives. Three generations of electrolyte additives were investigated and screened in NMC442/graphite pouch cells using a 24 h voltage-hold protocol at 40 degrees C to accelerate oxidative reactions occurring at 4.4 V. Once promising additives and combinations were identified, they were then tested in cobalt-free NMC640/graphite cells for long-term cycling to upper cutoff voltages of 4.3, 4.4, and 4.5 V at temperatures of 20, 40, and 55 degrees C. Degradation mechanisms were probed using dV/dQ analysis, micro-X-ray fluorescence spectroscopy, and electrochemical impedance spectroscopy. The primary failure mode of cells held at high voltages is due to increase in cell impedance, which is correlated to the dissolution of transition metals, specifically manganese, originating from the positive electrode. We believe this dissolution is presumably due to the formation of a high impedance rock salt surface layer on the NMC positive electrode particles. Such deleterious outcomes can be limited by selecting an appropriate electrolyte additive package. It is hoped that this paper can provide a starting point for developing NMC Li-ion cells that can operate to voltages as high as 4.4 V and still display long lifetimes.

Azam, Saad↗

Stress Corrosion Cracking of NaSICON Membranes in Aqueous Electrolytes for Redox-Flow Batteries

The sodium super-ionic conductor (NaSICON) has versatile applications as a ceramic electrolyte for energy storage, where it can serve as an impermeable separator in solid-state batteries and redox flow systems. In particular, NaSICON systems have been proposed to be relatively stable in contact with water, making them compatible with aqueous battery chemistries. However, owing to their brittle nature and metal oxide constituents, stress-corrosion cracking (SCC) is an important failure mechanism that has not been previously explored. In this study, we assess the fracture toughness of NaSICON membranes in contact with aqueous solutions that are relevant to redox flow systems. Microindentation was performed to generate visible surface cracks and residual stress, which were observed to grow in length after exposure to aqueous solutions. This allows for a quantitative measurement of fracture toughness, which decreases after exposure to water. To contextualize these results, we develop a simplified model of the fracture behavior in aqueous redox-flow batteries that incorporate NaSICON membranes, illustrating the importance of SCC in cell design. This work provides quantitative insights into SCC as a failure mode in NaSICON, enhancing our understanding of the chemo-mechanical behavior of ceramic electrolytes in contact with aqueous solutions.

Zhang, Mengyao↗

Durability Optimization of CO 2 Electrolyzers for Syngas Evolution

Recently, there has been an increased interest in mitigating anthropogenic CO 2 emissions through the electrochemical conversion of CO 2 into fuels and fuel feedstocks, including hydrogen gas (H 2 ), carbon monoxide (CO), and mixtures of the two to yield syngas. Commercial applications of these systems require high catalytic selectivity for the desired products, while exhibiting operational lifetimes exceeding thousands of hours. Advancements in this field have produced systems that display high selectivity of the desired products at faradaic efficiencies exceeding 95%. Despite the advancements made in CO 2 electrolysis, system durability remains a standing challenge in the field. CO 2 electrolyzer lifetimes are often limited by carbonate fouling, catalyst degradation, detrimental flooding of electrode microporous layers and anion exchange membrane (AEM) failures. In this report, a 5 cm 2 membrane electrode assembly (MEA) device is used to investigate potential failure modes and to optimize AEM CO 2 electrolyzer operation. Key findings of this study include the importance of CO 2 flow rate, use of a thin PiperION PTFE-reinforced membrane, optimizing compression to enhance contact under 40 in-lb compression, and the effect of more compressible, commercial iridium oxide anodes on system durability.

Abouremeleh, Mohammed H. [Lawrence Berkeley Nation↗

Mechanical Degradation of Graphite/PVDF Composite Electrodes: A Model-Experimental Study

Mechanical failure modes of a graphite/polyvinylidene difluoride (PVDF) composite electrode for lithium-ion batteries were investigated by combining realistic stress-stain tests and mathematical model predictions. Samples of PVDF mixed with conductive additive were prepared in a similar way to graphite electrodes and tested while submerged in electrolyte solution. Young's modulus and tensile strength values of wet samples were found to be approximately one-fifth and one-half of those measured for dry samples. Simulations of graphite particles surrounded by binder layers given the measured material property values suggest that the particles are unlikely to experience mechanical damage during cycling, but that the fate of the surrounding composite of PVDF and conductive additive depends completely upon the conditions under which its mechanical properties were obtained. Simulations using realistic property values produced results that were consistent with earlier experimental observations.

25 ENERGY STORAGE↗

Modeling Crack Propagation in Polycrystalline Microstructure Using Variational Multiscale Method

Crack propagation in a polycrystalline microstructure is analyzed using a novel multiscale model. The model includes an explicit microstructural representation at critical regions (stress concentrators such as notches and cracks) and a reduced order model that statistically captures the microstructure at regions far away from stress concentrations. Crack propagation is modeled in these critical regions using the variational multiscale method. In this approach, a discontinuous displacement field is added to elements that exceed the critical values of normal or tangential tractions during loading. Compared to traditional cohesive zone modeling approaches, the method does not require the use of any special interface elements in the microstructure and thus can model arbitrary crack paths. The capability of the method in predicting both intergranular and transgranular failure modes in an elastoplastic polycrystal is demonstrated under tensile and three-point bending loads.

36 MATERIALS SCIENCE↗

A New Method to Measure Crack Extension in Nuclear Graphite Based on Digital Image Correlation

Graphite components, used as moderators, reflectors, and core-support structures in a High-Temperature Gas-Cooled Reactor, play an important role in the safety of the reactor. Specifically, they provide channels for the fuel elements, control rods, and coolant flow. Fracture is the main failure mode for graphite, and breaching of the above channels by crack extension will seriously threaten the safety of a reactor. In this paper, a new method based on digital image correlation (DIC) is introduced for measuring crack extension in brittle materials. Cross-correlation of the displacements measured by DIC with a step function was employed to identify the advancing crack tip in a graphite beam specimen under three-point bending. The load-crack extension curve, which is required for analyzing the R-curve and tension softening behaviors, was obtained for this material. Furthermore, a sensitivity analysis of the threshold value employed for the cross-correlation parameter in the crack identification process was conducted. Finally, the results were verified using the finite element method.

Lai, Shigang↗

Sequence Diagrams & PFMEA Table - VGI [SWR-25-107]

As part of the VGI work under the National Charging Experience (ChargeX) Consortium, reliability analysis of communication interfaces for multiple SCM/VGI use-cases was performed using a Process Failure Modes and Analysis (PFMEA) style framework. This repository hosts all the relevant files for each of these use-cases which include: *A visual representation of their communication architecture: Image file (.png) *UML sequence diagram: Plant-UML source file (.puml). Visio file (.vsdx) and image file (.png) derived from the UML sourceX` *The PFMEA table: Excel file (.xlsx) These files are meant to serve as a starting point and can be adapted to company / organization specific SCM implementation.

Gadamsetty, Pranav [National Renewable Energy Labo↗

Genomic Language model for Annotation of Repetitive Elements (GLARE) v1.0

GLARE (Genomic Language model for Annotation of Repetitive Elements) is a tool that classifies transposable elements (TEs)—the mobile, repetitive DNA sequences that make up large fractions of eukaryotic genomes. GLARE fine-tunes the NTv3-650M genomic language model on a harmonized collection of curated TE sequences from the PanTEon and Repbase reference databases, assigning each input sequence to one of 11 orders and 32 superfamilies in a Wicker-compatible taxonomy. Features. From nucleotide FASTA input, GLARE outputs per-sequence predictions, class summaries, composition figures, and an annotated FASTA. It provides calibrated confidence scores with optional abstention and runs on CPU or GPU. Uses. GLARE serves as a classification component in genome-annotation pipelines, downstream of TE discovery, supporting genome annotation and comparative and evolutionary genomics. Advantages. GLARE is the first repeat-element classifier to leverage a pretrained genomic language model. Combined with multi-database training, this approach outperformed all nine classifiers in the PanTEon benchmark, generalized better to unseen taxonomic clades, and remained robust to sequence orientation—a common failure mode of existing tools.

Bruna, Tomas [Lawrence Berkeley National Laborator↗

EXPLORING THE USE OF COGNITIVE MODELS FOR NUCLEAR POWER PLANT HUMAN-SYSTEM INTERFACE EVALUATION

Much of the United States commercial nuclear power plant fleet is approaching the end of their operating licenses. To extend the life of these plants, advanced human-system interface (HSI) technologies are being researched to address aging and reliability concerns with the existing legacy instrumentation and controls. Human factors engineering (HFE) has a crucial role in ensuring these technologies are designed in a way that does not introduce new failure modes and promote optimal human-system performance. An important focus of HFE in NPP modernization is the early involvement to inform the design of the HSI. Here, traditional formative evaluations are done to collect design feedback. While these evaluations are absolutely useful, they are limited in providing convincing quantitative data for efficiency of use. This paper discusses the use of cognitive models to provide such quantitative data early in the HSI design process. A comparison of three open-source and readily accessible cognitive modeling tools are discussed.

99 GENERAL AND MISCELLANEOUS↗

The combined effect of temperature and seawater on the compression properties of carbon fiber vinyl ester composites for sandwich structures

For naval applications, composite sandwich structures are of significant interest, and are often manufactured using thin (2 to 4 mm) composite facings made from carbon or glass fiber reinforcement, attached to a thick (25 to 50 mm) section of PVC cellular foam or balsa wood-based core materials using a suitable polymeric resin. In the present study, we focus on the hygrothermal effect on the fiber-dominated compression properties of carbon fiber reinforced vinyl ester resin based polymeric composite (CF/VE), used as “skin” for a polymeric composite sandwich material. Hygrothermal conditioning is achieved by saturating samples in simulated seawater at 40°C. Compression properties are evaluated for coupons extracted along warp and fill undergoing- no conditioning, conditioning till saturation (up to 6 months), and long-term conditioning (2 years). Sea-water saturation yields in up to 12% drop in compression strength with a further 3–4% drop resulting from long-term conditioning. No statistically significant modulus degradation is noticed due to short or long-term hygrothermal exposure. The failure mechanism of the warp extracted coupon, which fails in a splitting failure mode originating due to the delamination between the 0/90 interface, or the fill extracted coupon, which fails due to the instability caused by tow micro-buckling, remains unchanged due to combined exposure (short or long-term) of seawater and temperature. The loss in strength is attributed to the degradation of the fiber-matrix interface, which is validated via conducting single fiber push-in tests with a nominal diameter of 7 micron for conditioned and unconditioned coupons.

Engineering↗

A novel physics-based and data-supported microstructure model for part-scale simulation of laser powder bed fusion of Ti-6Al-4V

The elasto-plastic material behavior, material strength and failure modes of metals fabricated by additive manufacturing technologies are significantly determined by the underlying process-specific microstructure evolution. In this work a novel physics-based and data-supported phenomenological microstructure model for Ti-6Al-4V is proposed that is suitable for the part-scale simulation of laser powder bed fusion processes. The model predicts spatially homogenized phase fractions of the most relevant microstructural species, namely the stable β-phase, the stable α s -phase as well as the metastable Martensite α m -phase, in a physically consistent manner. In particular, the modeled microstructure evolution, in form of diffusion-based and non-diffusional transformations, is a pure consequence of energy and mobility competitions among the different species, without the need for heuristic transformation criteria as often applied in existing models. The mathematically consistent formulation of the evolution equations in rate form renders the model suitable for the practically relevant scenario of temperature- or time-dependent diffusion coefficients, arbitrary temperature profiles, and multiple coexisting phases. Due to its physically motivated foundation, the proposed model requires only a minimal number of free parameters, which are determined in an inverse identification process considering a broad experimental data basis in form of time-temperature transformation diagrams. Subsequently, the predictive ability of the model is demonstrated by means of continuous cooling transformation diagrams, showing that experimentally observed characteristics such as critical cooling rates emerge naturally from the proposed microstructure model, instead of being enforced as heuristic transformation criteria. Eventually, the proposed model is exploited to predict the microstructure evolution for a realistic selective laser melting application scenario and for the cooling/quenching process of a Ti-6Al-4V cube of practically relevant size. Numerical results confirm experimental observations that Martensite is the dominating microstructure species in regimes of high cooling rates, e.g., due to highly localized heat sources or in near-surface domains, while a proper manipulation of the temperature field, e.g., by preheating the base-plate in selective laser melting, can suppress the formation of this metastable phase.

Inverse parameter identification↗

Damage mechanisms avoided or managed for NIF large optics

After every other failure mode has been considered, in the end, the high-performance limit of all lasers is set by optical damage. The demands of inertial confinement fusion (ICF) pushed lasers designed as ICF drivers into this limit from their very earliest days. The first ICF lasers were small, and their pulses were short. Their goal was to provide as much power to the target as possible. Typically, they faced damage due to high intensity on their optics. As requests for higher laser energy, longer pulse lengths, and better symmetry appeared, new kinds of damage also emerged, some of them anticipated and others unexpected. This paper will discuss the various types of damage to large optics that had to be considered, avoided to the extent possible, or otherwise managed as the National Ignition Facility (NIF) laser was designed, fabricated, and brought into operation. Furthermore, it has been possible for NIF to meet its requirements because of the experience gained in previous ICF systems and because NIF designers have continued to be able to avoid or manage new damage situations as they have appeared.

42 ENGINEERING↗

REGULATORY REQUIREMENTS, GUIDANCE, AND REVIEW OF EMBEDDED DIGITAL DEVICES IN SAFETY SYSTEMS

Interest in embedded digital devices (EDDs) for monitoring and providing control of components is increasing in the nuclear power market as more and more users both within and outside the nuclear sector are employing EDDs. EDDs in other industries or countries may be known by the related terms as smart devices, devices of limited functionality, or intelligent devices. EDDs can sometimes perform a safety role when embedded in components such as temperature transmitters, pressure transmitters, voltage regulators, gas analyzers, boiler controllers, relays, and radiation monitors. The introduction of EDDs can affect safety by creating new hazards, vulnerabilities, failure modes, triggering mechanisms, and other potential safety concerns at both the component and system levels. The U.S. Nuclear Regulatory Commission’s (NRC’s) existing regulations and guidance cover the use of EDDs in safety-related and important to safety systems in nuclear power plants (NPPs). In addition to potential future challenges, the nature of EDDs being implemented in similar or identical manners between different plants and industries opens up the potential of leveraging the reviews of other regulators or utilization of industry certifications.Key words: embedded digital device, firmware

Halverson, D. S.↗