Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Analysis of Brayton Cycles Utilizing Supercritical Carbon Dioxide

This white paper documents a detailed and extensive Brayton cycle analysis that was performed to better understand at a fundamental level the dependence of the Brayton cycle performance on operating conditions, working fluid, supercritical fluid properties, and some cycle non-idealities. This work was performed to better understand the factors controlling Brayton cycle performance and optimal operating conditions, particularly for cycles utilizing supercritical CO 2 (sCO 2 ) as the working fluid. The focus of this study is on cycle performance, particularly efficiency. No cost estimates were performed. However, as a single indirect measure of cycle cost, some sensitivity analyses on specific power (net output divided by working fluid mass flow rate) were included.

42 ENGINEERING↗

ARM Aerial Facility (AAF) - Unmanned Aircraft Systems, Fine Condensation Particle Counter via CVI Inlet, Quality Controlled

The Fine Condensation Particle Counter (or CPCF) measures sub-micron aerosol particle number concentration by condensing fluid onto particles and causing them to grow to sizes that are easily detectable by optical scattering. Counts particles with sizes that range from 10 to 3000 nanometers. Quality controlled and merged with AAF Nav data.

54 ENVIRONMENTAL SCIENCES↗

Aerothermal Analysis of the Rocket Lab Venus Probe Heatshield

This document provides an overview of the aerothermodynamic analyses performed by the Aerothermodynamics Branch at NASA Langley Research Center for the Rocket Lab Venus Probe (RLVP). In addition to defining the baseline heating environment to the heatshield, this document pursues the experimental validation of key physical models at RLVP-relevant conditions. This experimental validation analysis, which captures the model form uncertainty, is used as one of two primary components of the margin assessment, where the other component is the parametric uncertainty. These model form (experimental) and parametric uncertainty components are used to construct a spatial and time varying margin for the heating to the RLVP heatshield. The margin is evaluated as the sum of the parametric and model form uncertainty components. The model form uncertainty is defined as the difference between the RLVP-relevant measurements and their simulations, using the upper limit uncertainty bounds for both the measurements and simulations in the comparisons. The differences in the dominant physics in the stagnation region and flank lead to the separate RLVP-relevant measurements for assessing the model form uncertainty in these two regions. These regions are addressed as follows: Stagnation Region Heating Environment: For the high-temperature stagnation-region, both the radiative heating and impact of blowing on convective heating are significant, while the impacts of turbulence and roughness are negligible. Coupled radiation and ablation LAURA/HARA solutions with ray-tracing provide the radiative heating over the entire vehicle, including the contributions from the Venus atmosphere and ablation species. Non-ablating LAURA simulations provide the convective heating. During the material-response computation typically used for TPS sizing, this non-ablating convective heating is corrected for the impact of ablation using the blowing correction. Coupled ablation LAURA simulations that capture finite-rate sur-face processes show that this blowing correction may be non-conservative over most of the heatshield. This non-conservatism is due to hydrogen recombination in the finite-rate surface model, which tends to increase the coupled ablation convective heating to near the non-ablating values, therefore making any reduction in the non-ablating value through the blowing correction non-conservative. This non-conservatism due to H catalysis is captured in the parametric component of the margin. The best available ground-test measurements that capture the impact of blowing on stagnation region convective heating, at RLVP-relevant conditions, indicate that the current blowing reduction model is non-conservative by up to 20% at RLVP-relevant blowing rates (the coupled blowing simulations were also non-conservative). Because of the relatively low velocity of the ground tests and the non-Venus atmospheric chemistry, these measurements do not capture the chemistry and therefore do not inform the uncertainty due to H catalysis. However, they do capture the fluid mechanics of blowing. The non-conservatism of the blowing correction implied by these measurements is covered by the model form component of the margin, which leads to total margin values over 50%. For the radiative heating, the shock-tube informed bias approach suggests a model form uncertainty of roughly 20%, while the parametric uncertainty analysis suggests values over 100%. The combined stagnation-point radiation margin of over 100% leads to peak margined radiative heating values of over300 W/cm2, which remains small relative to the peak margined convective heating of nearly 2000 W/cm2. Based on this analysis, at the stagnation point, the peak margined heat rate is 2203 W/cm2 and the margined total heat load is 31.5 kJ/cm2 for the current nominal trajectory. Flank Heating Environment: The forebody flank (and near-shoulder) heating environment is dominated by the impact of turbulence, roughness augmentation, and ablation on the convective heating. An extensive collection of ground test measurements with RLVP-relevant turbulence and roughness is studied to show that the maximum difference between the simulated and measured convective heating is 5%. However, with the exception of the Holden measurements from the 1980s, these measurements do not include roughness elements extending into the supersonic region of the boundary layer, which is likely to occur for RLVP (due to the 45 degree sphere-cone geometry). The interaction between the supersonic flow and roughness could cause convective heating augmentation fundamentally different than for locally subsonic flow. Although these Holden measurements are consistent with the other measurements considered, another path was pursued to assure that the rough-ness height extending into supersonic flow does not fundamentally change the roughness augmentation. This additional path was a computational effort to resolve the roughness elements in the CFD grid, so that the interaction be-tween the roughness elements and locally supersonic flow may be simulated in detail. This roughness-resolved CFD simulation is feasible because of the RLVP forebody TPS’s patterned roughness, which may be approximated analytically, and because of the axisymmetric nominal flow field, which allows a narrow surface region to be simulated and therefore make the computational expense feasible. These grid-resolved roughness simulations, which are performed at actual RLVP flight conditions, result in heating augmentation values that are below the design approach for roughness augmentation. This provides evidence that the design approach for RLVP roughness augmentation is sufficient. Based on this analysis, at this flank or near-shoulder location, the peak margined total heat rate is 2088 W/cm2and the margined total heat load is 26.0 kJ/cm2for the current nominal trajectory. Heat flux, shear, pressure and heat transfer coefficient at the RLVP stagnation point and near shoulder location are evaluated for the entire trajectory, and curved fit to a functional form of F=AρB∞UC∞. These simplified relationships for the nominal and margined aerothermal environments are referred to as aerothermal indicators, and presented at the end of this document.

Christopher O Johnston↗

One-dimensional temperature measurement of supersonic jet flow by resonantly ionized photoemission thermometry of molecular nitrogen

As the field of fluid dynamics progresses, the demand for sophisticated diagnostic methods to accurately assess flow conditions rises. In this work, resonantly ionized photoemission thermometry (RIPT) has been used to directly target and ionize diatomic nitrogen (N 2 ) to measure one-dimensional (1D) temperature profiles in a supersonic jet flow. This technique can be considered non-intrusive as the premise uses resonantly enhanced multiphoton ionization (REMPI) to target molecular nitrogen. This resonance excites N 2 into absorption bands of the P, Q, and R rotational branches of N 2 ( b 1 Π u ). The ideal (3 + 1) REMPI scheme excites from the ground state and ionizes N 2 ( b 1 Π u ← X 1 Σ g + ) where de-excitation results in photoemission from the first negative band of ionized N 2 + ( B 2 Σ u + → X 2 Σ g + ) as nitrogen returns to the ground state. The resulting emission can be observed using an intensified camera, thus permitting inference of the rotational temperature of ground-state molecular nitrogen. A linearly regressive Boltzmann distribution is applied based on previous calibration data for this technique to quantify the temperature along the ionized line. This work applies this technique to a pure N 2 supersonic jet in cross-flow and counter-flow orientations to demonstrate N 2 RIPT’s applications in a supersonic flow. Temperature variations are observed at different locations downstream of the exit in cross-flow, and axisymmetric in counter-flow, to generate profiles characterizing the flow dynamics. Due to the collisional effects resulting from the number density of N 2 at higher pressures, a (3 + 2) REMPI scheme is observed throughout this text.

Clark, Aleksander (ORCID:0009000855600042)↗

Mechanism for negative water balance during weightlessness An hypothesis

The mechanism for the apparent decrease in body fluid volume in astronauts during spaceflight remains obscure. The widespread postulate that the hypohydration is the result of the Henry-Gauer reflex, a diuresis caused by inhibition of vasopressin secretion resulting from increased left and perhaps right atrial (central) venous pressure, has not been established with direct measurements on astronauts. An hypothesis is proposed to account for fluid-electrolyte shifts during weightlessness. A moderate but transient increase in central venous pressure occurs when orbit is entered that is insufficient to activate the Henry-Gauer reflex but sufficient to stimulate the release of atrial natriuretic peptides. Increased sodium excretion would facilitate some increased urinary water loss. The resulting relatively dilute plasma and interstitial fluids would cause fluid to shift into the cellular space, resulting in edema in the head and trunk and inhibition of thirst and drinking. Thus, the negative water balance in astronauts would be caused by a gradual natriuresis and diuresis coupled with reduced fluid intake.

Greenleaf, J. E.↗

Remote magneto-elastic analyte, viscosity and temperature sensing apparatus and associated methods of sensing

An analyte, viscosity, or temperature sensing apparatus for operative arrangement within a time-varying magnetic field, including a sensor with an outer surface that is chemically, frictionally, or thermally responsive and adhered to a base magnetostrictive element, and a receiver to measure a first and second value for magneto-elastic emission intensity of the sensor taken at, respectively, a first and second interrogation frequency. A change in mass or a change in material stiffness of the sensor due to the responsiveness, the viscosity and mass density of a fluid therearound, or the temperature, can be identified. The receiver, alternatively, measures a plurality of successive values for magneto-elastic emission intensity of the sensor taken over an operating range of successive interrogation frequencies to identify a value for the sensor's magneto-elastic resonant frequency (a fundamental frequency or harmonic thereof). Several sensors in an ordered array will provide a package of information.

Grimes, Craig A.↗

TWO-TEMPERATURE MODELS FOR POLAR PLUMES: COOLING BY MEANS OF STRONG BASE HEATING

In earlier one-fluid hydrodynamical calculations incorporating heat conduction and radiative losses, it was shown that the high densities in polar plumes could be reproduced by including a concentrated heat source near the plume base, in addition to the global heating required in both the plume and interplume regions of the coronal hole. The extra heating (attributed to interchange reconnection between the open flux and an underlying magnetic bipole) results in lower flow speeds and temperatures relative to the interplume gas, predictions that have since been confirmed by spectroscopic measurements. Here, the model is extended to the two-fluid case, in which ions and electrons are allowed to have different temperatures, coupling is via Coulomb collisions, and heat transport is mainly by electrons. Again, we find that depositing energy very close to the coronal base, in either the protons or electrons (or both), raises the densities and decreases the flow speeds everywhere along the flux tube. The higher densities in turn act to lower the ion temperatures by coupling the protons more closely to the energy-losing electrons. In addition, we find that energy must be deposited globally in both the electrons and the ions; without this direct heating, the electrons would end up cooler in the interplume region than in the plume, contrary to observations. Increasing the rate of flux-tube expansion has the effect of lowering the electron and ion temperatures and reducing the asymptotic flow speed, both in the plume and the interplume region; the observed densities and temperatures can be matched by taking the magnetic field to fall off with radius roughly as r{sup -4}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An experiment for Shuttle aerodynamic force coefficient determination from inflight dynamical and atmospheric measurements

A two-phase experiment is proposed which utilizes the Shuttle Orbiter and its unique series of repeated entries into the earth's atmosphere as an airborne in situ aerodynamic testing laboratory. The objective of the experiment is to determine static aerodynamic force coefficients, first of the orbiter, and later of various entry configurations throughout the high speed flight regime, including the transition from free molecule to continuum fluid flow. The objective will be accomplished through analysis of inflight measurements from both shuttle-borne and shuttle-launched instrumented packages. Results are presented to demonstrate the feasibility of such an experiment.

Compton, H. R.↗

Beam-plasma interactions in a positive ion-negative ion plasma

An electron-free plasma consisting of negative ions /SF6(-)/ and positive ions /Ar(+)/, and negligible neutral-ion collision frequencies has been created in the laboratory. This plasma has a mass ratio of approximately 3.5-similar to many computer particle-in-cell simulated systems. A fluid description of this positive and negative ion confinement (PANIC) plasma is given and compared to experimental measurements of a beam-plasma instability for both beam species and a wide range of beam energies. The fluid dispersion relation and most growing modes are predicted to be insensitive to many parameters of the PANIC beam-plasma system, and found to the consistent with the data.

Intrator, T.↗

Acoustic-Structure Interaction in Rocket Engines: Validation Testing

While analyzing a rocket engine component, it is often necessary to account for any effects that adjacent fluids (e.g., liquid fuels or oxidizers) might have on the structural dynamics of the component. To better characterize the fully coupled fluid-structure system responses, an analytical approach that models the system as a coupled expansion of rigid wall acoustic modes and in vacuo structural modes has been proposed. The present work seeks to experimentally validate this approach. To experimentally observe well-coupled system modes, the test article and fluid cavities are designed such that the uncoupled structural frequencies are comparable to the uncoupled acoustic frequencies. The test measures the natural frequencies, mode shapes, and forced response of cylindrical test articles in contact with fluid-filled cylindrical and/or annular cavities. The test article is excited with a stinger and the fluid-loaded response is acquired using a laser-doppler vibrometer. The experimentally determined fluid-loaded natural frequencies are compared directly to the results of the analytical model. Due to the geometric configuration of the test article, the analytical model is found to be valid for natural modes with circumferential wave numbers greater than four. In the case of these modes, the natural frequencies predicted by the analytical model demonstrate excellent agreement with the experimentally determined natural frequencies.

Davis, R. Benjamin↗

Stable light isotope biogeochemistry of hydrothermal systems

The stable isotopic composition of the elements O, H, S and C in minerals and other chemical species can indicate the existence, extent, conditions and the processes (including biological activity) of hydrothermal systems. Hydrothermal alteration of the 18O/16O and D/H values of minerals can be used to detect fossil systems and delineate their areal extent. Water-rock interactions create isotopic signatures which indicate fluid composition, temperature, water-rock ratios, etc. The 18O/16O values of silica and carbonate deposits tend to increase with declining temperature and thus help to map thermal gradients. Measurements of D/H values can help to decipher the origin(s) of hydrothermal fluids. The 34S/32S and 13C/12C values of fluids and minerals reflect the origin of the S and C as well as oxygen fugacities and key redox processes. For example, a wide range of 34S/32S values which are consistent with equilibration below 100 degrees C between sulfide and sulfate can be attributed to sulfur metabolizing bacteria. Depending on its magnitude, the difference in the 13C/12C value of CO2 and carbonates versus organic carbon might be attributed either to equilibrium at hydrothermal temperatures or, if the difference exceeds 1% (10/1000), to organic biosynthesis. Along the thermal gradients of thermal spring outflows, the 13C/12C value of carbonates and 13C-depleted microbial organic carbon increases, principally due to the outgassing of relatively 13C-depleted CO2.

Review, Tutorial↗

A decade of progress in understanding and managing legacy well integrity for geologic carbon storage

This study reviews a decade of research progress in legacy well integrity and risk management for geologic carbon storage (GCS) to commemorate the 20 th anniversary of the Intergovernmental Panel on Climate Change’s 2005 Special Report on Carbon Capture and Storage. In the past ten years, legacy well research has benefited from global efforts to constrain emissions from abandoned oil and gas wells, a continued focus on well materials performance in the presence of CO 2 -rich fluids, and practical experience gained through GCS implementation. Field measurements of abandoned well emissions show that leakage is not universal or catastrophic but forms a continuum of low-to-moderate fluxes that depend on isolation integrity and environmental attenuation. Materials research has constrained the conditions under which Portland cements exhibit self-sealing and non-sealing behaviors, and has identified the impact of geomechanical properties, non-uniform pathway apertures, multi-phase flow, and impurities in the CO 2 stream, on leakage pathways as important new areas for investigation. GCS projects at brownfield sites have inspired the creation of new workflows that integrate various tools and technologies to manage legacy well leakage risks. GCS implementation has also motivated a push towards scenario-based well modeling that directly informs permit applications. These advances inspire new research questions for the coming decade, particularly around the level of legacy well leakage risk that is environmentally acceptable and tolerable to stakeholders when sequestering millions of tonnes of CO 2 annually.

Carbon capture and storage↗

Above zone pressure interpretation for leaky well characterization and its identification from leaky caprock/fault

Pressure transient analysis has long been used for reservoir characterization. Above-zone (AZ) pressure has been recently investigated for inferring leakage pathway characteristics in leakage events from subsurface injection operations. The recorded pressure in the AZ should be purely related to leakage and therefore it can be safely inverted to deduce leakage characteristics. It is crucial to evaluate fluid leakage through abandoned wells to plan for further measurements of leakage prevention. However, the recorded AZ leakage signal may not be related to leaky well(s). Therefore, identification and spatial investigation of well leakage is required for leakage evaluation. Here in this paper, we propose a pressure interpretation method for early detection of leaky pathways, applying two observation points in the AZ. We distinguish leaky well, fault and caprock based on their corresponding flow regime identification. We show that the pressure difference of the two observation wells can be applied as a proxy for unknown leakage rate, which is crucial for leakage identification as well as characterization. Results show that the estimated location of the leaky well, leakage coefficient, and the leakage rate are in good agreement with the actual values. The estimated leakage coefficient of the leaky well can be used to evaluate well leakage in multiphase systems such as carbon dioxide leakage in deep saline aquifers.

02 PETROLEUM↗

Distribution of bisphenol A into tissues of adult, neonatal, and fetal Sprague-Dawley rats

Bisphenol A (BPA) is an important industrial chemical used in the manufacture of polycarbonate plastic products and epoxy resin-based food can liners. The presence of BPA metabolites in urine of > 90% of Americans aged 6-60 suggests ubiquitous and frequent exposure in the range of 0.02-0.2 {mu}g/kg bw/d (25th-95th percentiles). The current study used LC/MS/MS to measure placental transfer and concentrations of aglycone (receptor-active) and conjugated (inactive) BPA in tissues from Sprague-Dawley rats administered deuterated BPA (100 {mu}g/kg bw) by oral and IV routes. In adult female rat tissues, the tissue/serum concentration ratios for aglycone BPA ranged from 0.7 in liver to 5 in adipose tissue, reflecting differences in tissue perfusion, composition, and metabolic capacity. Following IV administration to dams, placental transfer was observed for aglycone BPA into fetuses at several gestational days (GD), with fetal/maternal serum ratios of 2.7 at GD 12, 1.2 at GD 16, and 0.4 at GD 20; the corresponding ratios for conjugated BPA were 0.43, 0.65, and 3.7. These ratios were within the ranges observed in adult tissues and were not indicative of preferential accumulation of aglycone BPA or hydrolysis of conjugates in fetal tissue in vivo. Concentrations of aglycone BPA in GD 20 fetal brain were higher than in liver or serum. Oral administration of the same dose did not produce measurable levels of aglycone BPA in fetal tissues. Amniotic fluid consistently contained levels of BPA at or below those in maternal serum. Concentrations of aglycone BPA in tissues of neonatal rats decreased with age in a manner consistent with the corresponding circulating levels. Phase II metabolism of BPA increased with fetal age such that near-term fetus was similar to early post-natal rats. These results show that concentrations of aglycone BPA in fetal tissues are similar to those in other maternal and neonatal tissues and that maternal Phase II metabolism, especially following oral administration, and fetal age are critical in reducing exposures to the fetus. - Highlights: > Studies of BPA in rat tissues showed placental transfer and fetal metabolism. > Levels in fetus are similar to maternal tissues. > Fetal metabolism can reduce levels.

60 APPLIED LIFE SCIENCES↗

Numerical Simulation and Experimental Study of the Gas–Solid Flow Behavior Inside a Full-Loop Circulating Fluidized Bed: Evaluation of Different Drag Models

Both experimental and computational studies of the fluidization of high-density polyethylene (HDPE) particles in a small-scale full-loop circulating fluidized bed (CFB) are conducted. Experimental measurements of pressure drop are taken at various locations along the bed. The solids circulation rate is measured with an advanced particle image velocimetry (PIV) technique. Bed height of the quasi-static region in the standpipe is also measured. Comparative numerical simulations are performed with a computational fluid dynamics solver utilizing a discrete element method (CFD-DEM). Here, this paper examines the effect of different drag laws used in the CFD simulations through a detailed and direct comparison with experimental data from a small-scale, full-loop circulating fluidized bed. The Hill–Koch–Ladd drag correlation was shown to have good agreement with respect to system component pressure drop and inventory height in the standpipe.

42 ENGINEERING↗

Note: Calibration of atomic force microscope cantilevers using only their resonant frequency and quality factor

A simplified method for calibrating atomic force microscope cantilevers was recently proposed by Sader et al. [Rev. Sci. Instrum. 83, 103705 (2012); Sec. III D] that relies solely on the resonant frequency and quality factor of the cantilever in fluid (typically air). This method eliminates the need to measure the hydrodynamic function of the cantilever, which can be time consuming given the wide range of cantilevers now available. Using laser Doppler vibrometry, we rigorously assess the accuracy of this method for a series of commercially available cantilevers and explore its performance under non-ideal conditions. This shows that the simplified method is highly accurate and can be easily implemented to perform fast, robust, and non-invasive spring constant calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron backscatter edges as a diagnostic of burn propagation

High gain in hotspot-ignition inertial confinement fusion (ICF) implosions requires the propagation of thermonuclear burn from a central hotspot to the surrounding cold dense fuel. As ICF experiments enter the burning plasma regime, diagnostic signatures of burn propagation must be identified. In previous work [A. J. Crilly et al., Phys. Plasmas 27(1), 012701 (2020)], it has been shown that the spectral shape of the neutron backscatter edges is sensitive to the dense fuel hydrodynamic conditions. The backscatter edges are prominent features in the ICF neutron spectrum produced by the 180° scattering of primary deuterium–tritium fusion neutrons from ions. In this work, synthetic neutron spectra from radiation-hydrodynamics simulations of burning ICF implosions are used to assess the backscatter edge analysis in a propagating burn regime. Significant changes to the edge's spectral shape are observed as the degree of burn increases, and a simplified analysis is developed to infer scatter-averaged fluid velocity and temperature. The backscatter analysis offers direct measurement of the increased dense fuel temperatures that result from burn propagation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗