Search NASA⌕ Search

SEARCH · Search NASA

Results for “Field Arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Recent Developments in Hydrogeologic Applications for Strain Tensor Analyses

Changes in fluid pressure deform porous media and this effect occurs in a variety of hydrogeologic processes, from the change in storage during pumping or injection to fluctuations in water levels caused by barometric pressure. We have developed instruments for measuring small strains in porous media, and we have used the resulting strain data to evaluate well testing, hydraulic fracturing, manual loading at the ground surface, and ambient hydrologic processes, like rainfall and evaporation. A particularly important application is the use of strain tensor data measured at shallow depths to analyze well tests or hydraulic fractures conducted at much greater depths. An early demonstration of this technique was conducted at the North Avant Field north of Tulsa, Oklahoma, where Pennsylvanian sandstone creates a confined aquifer and oil reservoir at a depth of 530m. We have showed that the strains caused by injecting into the aquifer could be measured at a depth of 30m and used to evaluate the properties of the aquifer. We recently expanded the array of strainmeters at the North Avant Field by deploying three more instruments at shallow depth (30m) along with a deep instrument at 520m depth in the winter, 2021. The deep instrument is deployed in shale caprock slightly above the aquifer. To our knowledge, the deep strainmeter at the North Avant Field is the deepest strainmeter ever deployed and this required refining methods originally developed for shallow deployments. The instrument was lowered to depth on oil field tubing and cemented in place using techniques and materials developed for use in oil wells. Optical fiber used to communicate with the instrument was cemented in the annulus on the outside of tubing. This is significant because the techniques we used could readily be extended to greater depth, suggesting that strainmeters can be deployed over a wide range of depths for monitoring critical subsurface processes. For example, it suggests that strainmeters could be deployed through the caprock to monitor for leaks from underlying CO2 storage reservoirs. The strainmeter array at the North Avant Field has been used to characterize deformation during a series of injection tests in the spring and summer, 2021. All the new strainmeters respond to pumping, and the strainmeters we installed earlier also responded. To our knowledge, this is the first application of well testing in a deep aquifer that was monitored by an array of strainmeters—our earlier work used strainmeters at a single location. We are currently analyzing the strain data using an analytical solution, a proxy-based Bayesian inversion algorithm, and other methods. Strainmeter data has also been used to characterize periodic pumping tests by us and Riley Blais. A periodically varying pumping rate causes both hydraulic head and strain signals that vary with the same period as the pumping. The peaks and troughs of the head in monitoring wells lag behind the peaks and troughs of the head in the pumping well, and this lag time increases with distance from the pumping well. The lag time of the pressure and the distance to the monitoring well can be used in a simple analysis to estimate the hydraulic diffusivity of the aquifer. The lag time determined from strain data can be used to estimate aquifer properties using the same analysis that works for the pressure only for strain data measured at particular locations. That is because the strain field in a confining unit advances upward, laterally and then downward even though the pressure in the underlying aquifer only advances laterally, according to our recent simulations. We have field data showing that a small periodic signal superimposed on an injection rate at the North Avant Field will create a periodic strain signal at shallow strainmeters. The field data and the recent simulations suggest that including a periodic component to injection or pumping and then monitoring the resulting strain signal could be a way to monitor the subsurface.

Murdoch, Larry↗

Coronal temperature, density, and magnetic field maps of a solar acitve region using the Owens Valley Solar Array

We present the first results of solar active region observations with the recently completed five-element Owens Valley Solar Array. On 1991 October 24, maps of Active Region AR 6891 were obtained at 22 frequencies from 1.2-7.0 GHz to provide brightness temperature spectra at each point. This is the first time that both high spatial and frequency-resolution brightness temperature spectra have been available over such a broad radio-frequency range. We find that over most of the region the spectra fall into one of the two well-defined categories: thermal free-free or thermal gyroresonance. In these cases, we use the spectra to deduce the spatial variation of physical parameters-electron temperature, column emission measure (intergral n(sup 2)(sub e) dl), and the coronal magnetic field strength-in and around the active region. Over a limited area of the region, the spectra resemble neither of the simple types, and alternative interpretations are required. The possibilties include the presence of fine structure that is unresolved at low frequencies; the presence of a small number of nonthermal electrons; or the presence of overlying, cooler 10(exp 6) K material which at low frequencies absorbs the hot (3 x 10(exp 6) K) thermal emission generated below.

Gary, Dale E.↗

Observations of interplanetary plasma waves, spacecraft noise, and sheath phenomena on Imp 7

The Imp 7 plasma wave instrument measures electric and magnetic wave components of plasma oscillations over the frequency range from 10 Hz to 100 kHz. The instrumentation and relevant external characteristics of the spacecraft that appear to be responsible for some in-flight disturbance effects are briefly described. It is shown that as each one of the 16 solar panel flats rotates into shadow or sunlight, the array transients produce fluctuating magnetic fields that are detected on the magnetic loop mounted 3.4 m from the spacecraft. These transients occur 16 times per spin period, and the corresponding magnetic noise has a high frequency on the rapidly spinning Imp 7 spacecraft. The analysis suggests that some Imp magnetic threshold levels measured 3-4 m from the spacecraft are determined by the solar array current transient effects associated with the discrete 16-sided geometry of the spacecraft. The geometry also influences the response of the electric dipole antenna by modulating the sheath.

Scarf, F. L.↗

Holographic imaging of natural-fiber-containing materials

The present invention includes methods and apparatuses for imaging material properties in natural-fiber-containing materials. In particular, the images can provide quantified measures of localized moisture content. Embodiments of the invention utilize an array of antennas and at least one transceiver to collect amplitude and phase data from radiation interacting with the natural-fiber-containing materials. The antennas and the transceivers are configured to transmit and receive electromagnetic radiation at one or more frequencies, which are between 50 MHz and 1 THz. A conveyance system passes the natural-fiber-containing materials through a field of view of the array of antennas. A computing device is configured to apply a synthetic imaging algorithm to construct a three-dimensional image of the natural-fiber-containing materials that provides a quantified measure of localized moisture content. The image and the quantified measure are both based on the amplitude data, the phase data, or both.

Bunch, Kyle J↗

Reconstruction Techniques for Sparse Multistatic Linear Array Microwave Imaging

Sequentially-switched linear arrays are an enabling technology for a number of near-field microwave imaging applications. Electronically sequencing along the array axis followed by mechanical scanning along an orthogonal axis allows dense sampling of a two-dimensional aperture in near real-time. In this paper, a sparse multi-static array technique will be described along with associated Fourier-Transform-based and back-projection-based image reconstruction algorithms. Simulated and measured imaging results are presented that show the effectiveness of the sparse array technique along with the merits and weaknesses of each image reconstruction approach.

concealed-weapon detection↗

An optically modulated zero-field atomic magnetometer with suppressed spin-exchange broadening

We demonstrate an optically pumped {sup 87}Rb magnetometer in a microfabricated vapor cell based on a zero-field dispersive resonance generated by optical modulation of the {sup 87}Rb ground state energy levels. The magnetometer is operated in the spin-exchange relaxation-free regime where high magnetic field sensitivities can be achieved. This device can be useful in applications requiring array-based magnetometers where radio frequency magnetic fields can induce cross-talk among adjacent sensors or affect the source of the magnetic field being measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NuSTAR extragalactic surveys: Initial results and catalog from the extended Chandra Deep Field South

We present the initial results and the source catalog from the Nuclear Spectroscopic Telescope Array (NuSTAR) survey of the Extended Chandra Deep Field South (hereafter, ECDFS)—currently the deepest contiguous component of the NuSTAR extragalactic survey program. The survey covers the full ≈30′ × 30′ area of this field to a maximum depth of ≈360 ks (≈220 ks when corrected for vignetting at 3–24 keV), reaching sensitivity limits of ≈1.3×10{sup −14} erg s{sup −1} cm{sup −2} (3–8 keV), ≈3.4×10{sup −14} erg s{sup −1} cm{sup −2} (8–24 keV), and ≈3.0×10{sup −14} erg s{sup −1} cm{sup −2} (3–24 keV). A total of 54 sources are detected over the full field, although five of these are found to lie below our significance threshold once contaminating flux from neighboring (i.e., blended) sources is taken into account. Of the remaining 49 that are significant, 19 are detected in the 8–24 keV band. The 8–24 to 3–8 keV band ratios of the 12 sources that are detected in both bands span the range 0.39–1.7, corresponding to a photon index range of Γ≈0.5−2.3, with a median photon index of Γ-bar =1.70±0.52. The redshifts of the 49 sources in our main sample span the range z=0.21−2.7, and their rest-frame 10–40 keV luminosities (derived from the observed 8–24 keV fluxes) span the range L{sub 10−40 keV}≈(0.7−300)×10{sup 43} erg s{sup −1}, sampling below the “knee” of the X-ray luminosity function out to z∼0.8−1. Finally, we identify one NuSTAR source that has neither a Chandra nor an XMM-Newton counterpart, but that shows evidence of nuclear activity at infrared wavelengths and thus may represent a genuine, new X-ray source detected by NuSTAR in the ECDFS.

79 ASTRONOMY AND ASTROPHYSICS↗

The Development of Microshutters for the Near Infrared Spectrograph on the James Webb Space Telescope

One of the James Webb Space Telescope's (JWST) primary science goals is to characterize the epoch of galaxy formation in the universe and observe the first galaxies and clusters of galaxies. This goal requires multi-band imaging and spectroscopic data in the near infrared portion of the spectrum for large numbers of very faint galaxies. Because such objects are sparse on the sky at the JWST resolution, a multi-object spectrograph is necessary to efficiently carry out the required observations. We have developed a fully programmable microshutter array that will be used as the field selector for the Near Infrared Spectrograph (NIRSpec) on JWST. This device allows slits to be opened at the locations of selected galaxies in the field of view while blocking other unwanted light from the sky background and bright sources. In practice, greater than 100 objects within the field of view will be observed simultaneously. In this paper, we describe the microshutter arrays, their development, fabrication, testing, and progress toward delivery of flight qualified devices to the NIRSpec instrument team in 2008.

Silverberg, Robert F.↗

Method of forming pointed structures

A method of forming an array of pointed structures comprises depositing a ferrofluid on a substrate, applying a magnetic field to the ferrofluid to generate an array of surface protrusions, and solidifying the surface protrusions to form the array of pointed structures. The pointed structures may have a tip radius ranging from approximately 10 nm to approximately 25 micron. Solidifying the surface protrusions may be carried out at a temperature ranging from approximately 10 degrees C. to approximately 30 degrees C.

Pugel, Diane E.↗

Preparation and characterization of Zr doped TiO{sub 2} nanotube arrays on the titanium sheet and their enhanced photocatalytic activity

This paper described a new method for the preparation of Zr doped TiO{sub 2} nanotube arrays by electrochemical method. TiO{sub 2} nanotube arrays were prepared by anodization with titanium anode and platinum cathode. Afterwards, the formed TiO{sub 2} nanotube arrays and Pt were used as cathode and anode, respectively, for preparation of Zr/TiO{sub 2} nanotube arrays in the electrolyte of 0.1 M Zr(NO{sub 3}){sub 4} with different voltage and post-calcination process. The nanotube arrays were characterized by field-emission scanning electron microscopy (FESEM), X-ray diffraction (XRD), X-ray photoelectron spectra (XPS) and UV-Vis diffusion reflection spectra (DRS). The photocatalytic activities of these nanotubes were investigated with Rhodamine B as the model pollutant and the results demonstrated that the photocatalytic efficiency of Zr doped TiO{sub 2} nanotubes was much better than that of TiO{sub 2} nanotubes under UV irradiation. Zr/TiO{sub 2} nanotube arrays doped at 7 V and calcined at 600 deg. C (denoted as TiO{sub 2}-7 V-600) achieved the best photocatalytic efficiency and the most optimal doping ratio was 0.047 (Zr/Ti). TiO{sub 2}-7 V-600 could be reused for more than 20 times and maintained good photocatalytic activities. - Graphical abstract: Zr-doped TiO{sub 2} nanotube arrays were prepared by two-step electrochemical process. The photocatalytic efficiency of Zr/TiO{sub 2} was much better than that of TiO{sub 2} nanotubes under UV irradiation. Nanotube arrays prepared by this method could be reused for more than 20 times and maintained good photocatalytic activities.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Helicon waves in uniform plasmas. II. High m numbers

Helicons are whistler modes with azimuthal wave numbers. They have been studied in solids and plasmas where boundaries play a role. The present work shows that very similar modes exist in unbounded gaseous plasmas. Instead of boundaries, the antenna properties determine the topology of the wave packets. The simplest antenna is a magnetic loop which excites m = 0 or m = 1 helicons depending on whether the dipole moment is aligned parallel or perpendicular to the ambient background magnetic field B{sub 0}. While these low order helicons have been described by J. M. Urrutia and R. L. Stenzel [“Helicon modes in uniform plasmas. I. Low m modes,” Phys. Plasmas 22, 092111 (2015)], the present work focuses on high order modes up to m = 8. These are excited by antenna arrays forming magnetic multipoles. Their wave magnetic field has been measured in space and time in a large and uniform laboratory plasma free of boundary effects. The observed wave topology exhibits m pairs of unique field line spirals which may have inspired the name “helicon” to this mode. All field lines converge into these nested spirals which propagate like corkscrews along B{sub 0}. The field lines near the axis of helicons are perpendicular to B{sub 0} and circularly polarized as in parallel whistlers. Helical antennas couple to these transverse fields but not to the spiral fields of helicons. Using a circular antenna array of phased m = 0 loops, right or left rotating or non-rotating multipole antenna fields are generated. They excite m < 0 and m > 0 modes, showing that the plasma supports both modes equally well. The poor excitation of m < 0 modes is a characteristic of loops with dipole moment across B{sub 0}. The radiation efficiency of multipole antennas has been found to decrease with m.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scalable graphene sensor array for real-time toxins monitoring in flowing water

Abstract Risk management for drinking water often requires continuous monitoring of various toxins in flowing water. While they can be readily integrated with existing water infrastructure, two-dimensional (2D) electronic sensors often suffer from device-to-device variations due to the lack of an effective strategy for identifying faulty devices from preselected uniform devices based on electronic properties alone, resulting in sensor inaccuracy and thus slowing down their real-world applications. Here, we report the combination of wet transfer, impedance and noise measurements, and machine learning to facilitate the scalable nanofabrication of graphene-based field-effect transistor (GFET) sensor arrays and the efficient identification of faulty devices. Our sensors were able to perform real-time detection of heavy-metal ions (lead and mercury) and E. coli bacteria simultaneously in flowing tap water. This study offers a reliable quality control protocol to increase the potential of electronic sensors for monitoring pollutants in flowing water.

47 OTHER INSTRUMENTATION↗

Coherent Beam Combining of High Power Broad-Area Laser Diode Array with a Closed-V-shape External Talbot Cavity

We have coherently combined a high-power broad-area laser diode array by using a feedback loop closed off-axis external Talbot cavity. The off-axis feedback from two gratings provides transverse-mode control of broad-area lasers. The Talbot configuration of the external cavity implements diffractive coupling among laser diodes. Feedback from two gratings increases external cavity quality factor and spectrum selection capability. As a result, spatial coherence was improved and spectral linewidth was narrowed down. The high visibility of the far-field profile indicates that high spatial coherence was achieved. We also observed symmetric far-field profiles indicating that laser array was phase locked to in-phase and out-of-phase super-modes, respectively. Transition between these super-modes was observed by tuning one grating's tilted angle.

42 ENGINEERING↗

Scalable electric-field-assisted fabrication of vertically aligned carbon nanotube membranes with flow enhancement

In this work, we report a solution-based approach for fabricating vertically aligned carbon-nanotube (VACNT) membranes, which improves on the unaligned nature of CNT mixed-matrix membranes. This approach addresses important challenges regarding scalability and incorporation of different types and sizes of nanotube as pores in a membrane. In a new, solvent-deposition approach, CNTs are dispersed and then aligned and concentrated via electro-deposition from an organic solvent, using a composite AC + DC electric field to form aligned CNT arrays. This enables VACNT number densities that are two orders-of-magnitude higher than possible from direct suspension of CNTs in the liquid oligomer. The solvent is then replaced by a UV-curable oligomer, which is selectively cured to form macroscopic membranes of highly controlled thickness. After plasma etching to open pores, the VACNT membranes are shown to be permeable, and to have pore sizes consistent with flow through internal channels of the CNTs. In a first for field-aligned, solution-fabricated VACNT membranes, the pores show substantial, 100–300 × , gas-flow enhancement compared to theory, similar to membranes fabricated via less scalable methods (i.e., by CVD growth of already aligned CNT forests). The solution-based, electric-field-assisted approach aligns nanotubes of different sizes and types grown by any means, and is scalable to the efficient fabrication of large-area VACNT membranes for a variety of important applications.

36 MATERIALS SCIENCE↗

Acoustic Source Localization in Aircraft Interiors Using Microphone Array Technologies

Using three microphone array configurations at two aircraft body stations on a Boeing 777-300ER flight test, the acoustic radiation characteristics of the sidewall and outboard floor system are investigated by experimental measurement. Analysis of the experimental data is performed using sound intensity calculations for closely spaced microphones, PATCH Inverse Boundary Element Nearfield Acoustic Holography, and Spherical Nearfield Acoustic Holography. Each method is compared assessing strengths and weaknesses, evaluating source identification capability for both broadband and narrowband sources, evaluating sources during transient and steady-state conditions, and quantifying field reconstruction continuity using multiple array positions.

Sklanka, Bernard J.↗

Separate-contact phase-locked semiconductor laser arrays

The novel optoelectronic devices discussed, phase-locked semiconductor laser arrays with separate contacts can perform a variety of near field and far field pattern tailoring functions and control mutual coherence among array elements, as well as lasing wavelength selectivity and tunability. Attention is presently given to experimental results from such arrays, which indicate that the threshold currents of the 4-micron wide lasers employed are typically 60 mA. The separate contacts to each one of them are provided by means of two-level metallization.

Katz, J.↗

Optimizing the differential connection schemes for detecting 3D magnetic perturbations in DIII-D

Optimizing the differential pair connection scheme (i.e. the set of pairs) of a toroidal array of magnetic sensors dedicated to measuring slowly rotating asymmetric fields can enhance the mode number detection capability and failure-resilience. In this work the condition number obtained from singular value decomposition (SVD) of the design matrix is used as a metric to evaluate the quality of a connection scheme. A large number of possible pair connections are usually available, so evaluating all of them may require extensive use of computational resources and can be very time consuming. Alternative methods to reduce the number of pairs evaluated without losing the capabilities of toroidal mode detection are presented in this paper. Here, three examples of the applications of such analysis for the 3D magnetic diagnostic system of DIII-D are also presented: the addition of two new toroidal arrays with n > 3 detection capabilities, the modification of an existing toroidal array in the low field side of the machine to accommodate the addition of a helicon antenna, and the design of changes in several toroidal arrays in the high field side to accommodate the addition of a lower hybrid current drive antenna on the center post.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗