Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Voltage Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Methods for diagnosing and quantifying double pulsing in a Uranium Neutron Collar system using shift register logic

Double pulsing in neutron coincidence counters is the result of a pulse processing chain-3He proportional counter timing incompatibility known to nondestructive assay system designers. It is not currently widely acknowledged, or accounted for, in the user community. However, it is gaining attention as list mode data acquisition and analysis becomes more commonly used for system diagnostics, revealing features that have been overlooked by historic timing gate selection using traditional shift register data acquisition methods. Double pulsing increases the apparent number of measured neutron events from a source. Therefore, it may contribute to a falsely increased count rate if present at the operational high voltage used when assaying samples, even with set predelays. The authors have previously studied the effects of double pulsing, using list mode data acquisition and analysis on neutron pulse trains in three common neutron coincidence counting systems used in routine measurements for international safeguards: a Canberra Industries JCC-71 Neutron Coincidence Collar, a variant on the Canberra Industries JCC-51 Active Well Neutron Coincidence Counter (the Large Volume Active Well Neutron Coincidence Counter), and an AnTech Inc. N2071 Neutron Coincidence Collar. We find that this non-ideal behavior was isolated to the Amptek A111 Charge Sensitive Preamplifier & Discriminator chip used in both the Canberra Industries and Antech systems. The double pulsing fraction was calculated in post-analysis for various high voltage settings in these A111-based systems, assuming no predelay settings. In this work, the authors expand upon this identification and analysis to make it more translatable between list mode data acquisition and analysis and shift register-based analysis. By investigating the double pulsing fractions in a JCC-71 Uranium Neutron Collar as a function of predelay settings, as well as describing and performing alternative tests and analyses to diagnose and quantify the double pulsing using shift register logic, this work hopes to complete the picture of double pulsing identification and analysis.

Safeguards↗

Comparing smoothing techniques for extracting MOSFET threshold voltage

Measurement noise acts as a barrier to the accurate calculation of threshold voltage by derivative-based extraction methods. We examined several smoothing techniques and their effects on measurement noise in threshold voltage extracted by the linear extrapolation method and the g m /I d method. We applied these techniques on a set of SiC power MOSFET devices before and after they had undergone accelerated thermal testing. The smoothing methods examined are least-squares polynomial fitting, low-pass filtering using Butterworth and Chebyshev fillers, and differential smoothing. These methods are compared by their shift in threshold voltage compared to unsmoothed data and their standard deviation among the measurements of each device. All methods performed poorly at smoothing when extracting via the g m /I d due to the large amounts of high-magnitude subthreshold noise, mostly tending to extract threshold voltages far below the expected value. Differential smoothing provided results closest to the expected value with an absolute shift of 1.2 V on average. The smoothing methods performed better with the LE method. On a failed device, all smoothing methods except polynomial smoothing preserved the large threshold voltage anomaly for four out of five measurements. These results show that choice of smoothing method, if used must be evaluated based on the device and extraction method.

42 ENGINEERING↗

Boron ion source based on planar magnetron discharge in self-sputtering mode

An ion source based on a planar magnetron sputtering device with thermally isolated target has been designed and demonstrated. For a boron sputtering target, high target temperature is required because boron has low electrical conductivity at room temperature, increasing with temperature. The target is well-insulated thermally and can be heated by an initial low-current, high-voltage discharge mode. A discharge power of 16 W was adequate to attain the required surface temperature (400 C), followed by transition of the discharge to a high-current, low-voltage mode for which the magnetron enters a self-sputtering operational mode. Beam analysis was performed with a time-of-flight system; the maximum boron ion fraction in the beam is greater than 99%, and the mean boron ion fraction, time-integrated over the whole pulse length, is about 95%. We have plans to make the ion source steady state and test with a bending magnet. This kind of boron ion source could be competitive to conventional boron ion sources that utilize compounds such as BF3, and could be useful for semiconductor industry application.

43 PARTICLE ACCELERATORS↗

Experimental Results from Droop Compensation for the High Voltage Converter Modulators

The High Voltage Convertor Modulators are used to power the RF klystrons used throughout the linear accelerator at the Spallation Neutron Source. The output voltage of the modulator has significant voltage droop and ripple which, combined with low level RF system limitations, affect performance and stability of the accelerator cavities. In conjunction with the progress in the development of the new controller, different modulation techniques were implemented and studied on the test modulator. This paper discusses experimental results from implementation of different modulation schemes has on the modulator output voltage pulse. Thermal measurements were carried out to determine the effect of these modulations schemes on long term reliability of the modulator. Future plans are also discussed.

Accelerators↗

A Time-Domain Protection Approach for AC Transmission Systems With Grid-Forming Resources

Ac transmission protection must reliably detect, classify, and locate short-circuit faults from voltage and current measurements. At present, these functionalities, which have been classically engineered using phasors approaches, are being challenged by the dynamic behavior and fault-current limits of converter-based generation. This paper tackles these challenges by engineering a time-domain protection approach that leverages the classical Bergeron model in a new manner. Low- and high-impedance faults are detected and classified by ascertaining how well line voltage and current measurements match the Bergeron equations. Faults are located by posing a novel one-variable optimization problem, whereas voltage and current waveforms at the fault location are estimated by unveiling rigorous relationships. The proposed elements are secure against external faults, measurement errors, and variation of line parameters and sampling time. Furthermore, these advances are tested via electromagnetic transient simulations and are significant to satisfy IEEE and North American Electric Reliability Corporation requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ferroelectric switch for a high-power Ka-band active pulse compressor

Results are presented for design of a high-power microwave switch for operation at 34.3 GHz, intended for use in an active RF pulse compressor. The active element in the switch is a ring of ferroelectric material, whose dielectric constant can be rapidly changed by application of a high-voltage pulse. As envisioned, two of these switches would be built into a pair of delay lines, as in SLED-II at SLAC, so as to allow 30-MW μs-length Ka-band pulses to be compressed in time by a factor-of-9 and multiplied in amplitude to generate 200 MW peak power pulses. Such high-power pulses could be used for testing and evaluation of high-gradient mm-wave accelerator structures, for example. Evaluation of the switch design was carried out with an X-band (11.43 GHz) prototype, built to incorporate all the features required for the Ka-band version.

43 PARTICLE ACCELERATORS↗

Lightweight concentrator module with 30 percent AM0 efficient GaAs/GaSb tandem cells

A concept is presented for an aerospace concentrator module with lightweight domed lenses and 30 percent AM0 efficient GaAs/GaSb tandem solar cell circuits. The performance of transparent GaAs cells is reviewed. NASA's high-altitude jet flight calibration data for recent GaSb cells assembled with bulk GaAs filters are reported, along with subsequent Boeing and NASA measurements of GaSb I-V performance at various light levels and temperatures. The expected performance of a basic two-terminal tandem concentrator circuit with three-to-one voltage matching is discussed. All of the necessary components being developed to assemble complete flight test coupons are shown. Straightforward interconnect and assembly techniques yield voltage matched circuits with near-optimum performance over a wide temperature range.

Avery, J. E.↗

NASA Tech Briefs, April 2011

Topics covered include: Amperometric Solid Electrolyte Oxygen Microsensors with Easy Batch Fabrication; Two-Axis Direct Fluid Shear Stress Sensor for Aerodynamic Applications; Target Assembly to Check Boresight Alignment of Active Sensors; Virtual Sensor Test Instrumentation; Evaluation of the Reflection Coefficient of Microstrip Elements for Reflectarray Antennas; Miniaturized Ka-Band Dual-Channel Radar; Continuous-Integration Laser Energy Lidar Monitor; Miniaturized Airborne Imaging Central Server System; Radiation-Tolerant, SpaceWire-Compatible Switching Fabric; Small Microprocessor for ASIC or FPGA Implementation; Source-Coupled, N-Channel, JFET-Based Digital Logic Gate Structure Using Resistive Level Shifters; High-Voltage-Input Level Translator Using Standard CMOS; Monitoring Digital Closed-Loop Feedback Systems; MASCOT - MATLAB Stability and Control Toolbox; MIRO Continuum Calibration for Asteroid Mode; GOATS Image Projection Component; Coded Modulation in C and MATLAB; Low-Dead-Volume Inlet for Vacuum Chamber; Thermal Control Method for High-Current Wire Bundles by Injecting a Thermally Conductive Filler; Method for Selective Cleaning of Mold Release from Composite Honeycomb Surfaces; Infrared-Bolometer Arrays with Reflective Backshorts; Commercialization of LARC (trade mark) -SI Polyimide Technology; Novel Low-Density Ablators Containing Hyperbranched Poly(azomethine)s; Carbon Nanotubes on Titanium Substrates for Stray Light Suppression; Monolithic, High-Speed Fiber-Optic Switching Array for Lidar; Grid-Tied Photovoltaic Power System; Spectroelectrochemical Instrument Measures TOC; A Miniaturized Video System for Monitoring Drosophila Behavior; Hydrofocusing Bioreactor Produces Anti-Cancer Alkaloids; Creep Measurement Video Extensometer; Radius of Curvature Measurement of Large Optics Using Interferometry and Laser Tracker n-B-pi-p Superlattice Infrared Detector; Safe Onboard Guidance and Control Under Probabilistic Uncertainty; General Tool for Evaluating High-Contrast Coronagraphic Telescope Performance Error Budgets; Hidden Statistics of Schroedinger Equation; Optimal Padding for the Two-Dimensional Fast Fourier Transform; Spatial Query for Planetary Data; Higher Order Mode Coupling in Feed Waveguide of a Planar Slot Array Antenna; Evolutionary Computational Methods for Identifying Emergent Behavior in Autonomous Systems; Sampling Theorem in Terms of the Bandwidth and Sampling Interval; Meteoroid/Orbital Debris Shield Engineering Development Practice and Procedure; Self-Balancing, Optical-Center-Pivot, Fast-Steering Mirror; Wireless Orbiter Hang-Angle Inclinometer System; and Internal Electrostatic Discharge Monitor - IESDM.

Source record↗

Robust Adaptive Decentralized Dynamic State Estimation with Unknown Control Inputs using Field PMU Measurements

This paper proposes a robust adaptive decentralized dynamic state estimation method for power system with unknown inputs of the highly detailed synchronous machine model. The temporal and spatial correlations among the unknown inputs are used to derive a vector auto-regressive model. The latter is further integrated together with state transition and measurement models for joint state and unknown inputs estimation. Thanks to the consideration of implicit cross-correlations between the states and the unknown inputs, only generator terminal voltage and current phasors are needed. Test results on the US WECC system using the field PMU measurements show that the proposed method is able to track both the system dynamic states and unknown controller inputs. These information could significantly benefit the validation and calibration of generator controller parameters.

Zhao, Junbo↗

Modeling Framework to Analyze Performance and Structural Reliability of Solid Oxide Electrolysis Cells

Solid oxide electrolysis cells (SOEC) have been receiving significant attention recently because of their high energy efficiency and fast hydrogen production. In this study a multi-physics model to simulate the SOEC performance and structural reliability of a state-of-the-art planar SOEC design was developed. The electrochemical reactions, fluid dynamics, species transport, electron transfer, and heat transfer were modeled in the commercial computational fluid dynamics (CFD) software STAR-CCM+. The thermomechanical analysis and the associated structural reliability evaluations were conducted using the commercial finite element analysis software ANSYS. The electrochemistry model was validated by using the experimentally obtained current-voltage (I-V) characteristics of the electrode-supported SOECs. The reliability analysis using a risk-of-rupture approach showed low failure probabilities under standard operating conditions considered in this study. For cells operated at voltages well above a thermoneutral voltage, the reliability evaluations indicated a potential risk of cell failure, but the damage was concentrated locally in specific areas of the cell which typically do not lead to total loss of cell function. The presented approach provides insights for evaluating representative cell and stack performances and structural reliability without intensive testing and for developing optimally performing and structurally reliable SOECs for efficient hydrogen generation.

25 ENERGY STORAGE↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

In situ TEM and synchrotron characterization of U–10Mo thin specimen annealed at the fast reactor temperature regime

U–Mo metallic alloys have been extensively used for the Reduced Enrichment for Research and Test Reactors (RERTR) program, which is now known as the Office of Material Management and Minimization under the Conversion Program. This fuel form has also recently been proposed as fast reactor metallic fuels in the recent DOE Ultra-high Burnup Fast Reactor project. In order to better understand the behavior of U–10Mo fuels within the fast reactor temperature regime, a series of annealing and characterization experiments have been performed. Annealing experiments were performed in situ at the Intermediate Voltage Electron Microscope (IVEM-Tandem) facility at Argonne National Laboratory (ANL). An electro-polished U–10Mo alloy fuel specimen was annealed in situ up to 700 °C. At an elevated temperature of about 540 °C, the U–10Mo specimen underwent a relatively slow microstructure transition. Nano-sized grains were observed to emerge near the surface. At the end temperature of 700 °C, the near-surface microstructure had evolved to a nano-crystalline state. In order to clarify the nature of the observed microstructure, Laue diffraction and powder diffraction experiments were carried out at beam line 34-ID of the Advanced Photon Source (APS) at ANL. Phases present in the as-annealed specimen were identified with both Laue diffraction and powder diffraction techniques. The U–10Mo was found to recrystallize due to thermally-induced recrystallization driven by a high density of pre-existing dislocations. A separate in situ annealing experiment was carried out with a Focused Ion Beam processed (FIB) specimen. A similar microstructure transition occurred at a lower temperature of about 460 °C with a much faster transition rate compared to the electro-polished specimen. - Highlights: • TEM annealing experiments were performed in situ at the IVEM facility up to fast reactor temperature. • At 540 °C, the U-10Mo specimen underwent a slow microstructure transition where nano-sized grains were observed to emerge. • UO{sub 2} phase exists at the thin area of the as-annealed specimen whereas U-10Mo γ phase dominated at the thicker part. • Bcc γ U-10Mo recrystallized to become nano-meter sized crystallites near the specimen surface. • A separateannealing experiment was conducted with a FIB processed specimen where similar transition occurred at a lower temperature of 460 °C with a faster rate.

36 MATERIALS SCIENCE↗

High-efficiency selective boron emitter formed by wet chemical etch-back for n -type screen-printed Si solar cells

Front metal contact induced recombination and resistance are major efficiency limiting factors of large-area screen-printed n-type front junction Si solar cells with homogeneous emitter and tunnel oxide passivated back contact (TOPCON). Here, this paper shows the development of a selective boron emitter (p + /p ++ ) formed by a screen-printed resist masking and wet chemical etch-back process, which first grows a porous Si layer and subsequently removes it. Various wet-chemical solutions for forming porous Si layer are investigated. An industrial compatible process with sodium nitrite (NaNO 2 ) catalyst is developed to uniformly etch-back the ~47 Ω/ atmospheric pressure chemical vapor deposited heavily doped boron emitter to ~135 Ω/ by growing a 320 nm porous Si layer within 3 min and subsequently removing it. After etching back, the boron emitter was subjected to a thermal oxidation to lower the surface concentration and the emitter saturation current density J 0e . Various etched-back emitters were evaluated by measuring J 0e on symmetric test structures with atomic layer deposited aluminum oxide (Al 2 O 3 ) passivation. Very low J 0e of 21, 14, and 9 fA/cm 2 were obtained for the 120, 150, and 180 Ω/ etched-back emitters, respectively. A solar cell with a selective emitter (65/180 Ω/ ) formed by this etch-back technology and with an Al/Ag contact on the front and TOPCON on the back gave an open-circuit voltage (V oc ) of 682.8 mV and efficiency of 21.04% on n-type Czochralski Si wafer. Finally, this demonstrates the potential of this technology for next generation high-efficiency industrial n-type Si solar cells.

14 SOLAR ENERGY↗

Impact of illumination and encapsulant resistivity on polarization-type potential-induced degradation on n-PERT cells

Power loss caused by polarization-type potential-induced degradation (PID-p) in a variety of high-performance photovoltaic cell types has been observed to be recoverable via subsequent illumination and in some cases preventable via simultaneous illumination. In this report, we describe the results of a study in which the front faces of n-PERT cells encapsulated in polymers with a broad range of electrical resistivity were exposed to varying and controlled irradiance during PID testing. For a low resistivity ethylene-vinyl acetate copolymer encapsulant, no reduction in the rate or extent of power loss was observed for irradiance as high as 1,000 W/m 2 , whereas for high and intermediate resistivity polyolefin encapsulants, 100 and 300 W/m 2 , respectively, prevented power loss. We introduce a simple model based on charge accumulation that facilitates interpretation of these results whereby degradation via charge accumulation under voltage stress and recovery due to light exposure are opposing and interdependent phenomena that describe the susceptibility of a module to power loss.

14 SOLAR ENERGY↗

Pt Nanoparticles on Atomic-Metal-Rich Carbon for Heavy-Duty Fuel Cell Catalysts: Durability Enhancement and Degradation Behavior in Membrane Electrode Assemblies

Proton exchange membrane fuel cells (PEMFCs) are a promising zero-emission power source for heavy-duty vehicles (HDVs). However, long-term durability of up to 25,000 h is challenging because current carbon support, catalyst, membrane, and ionomer developed for traditional light-duty vehicles cannot meet the stringent requirement. Therefore, understanding catalyst degradation mechanisms under the HDV condition is crucial for rationally designing highly active and durable platinum group metal (PGM) catalysts for high-performance membrane electrode assemblies (MEAs). Herein, we report a PGM catalyst consisting of platinum nanoparticles with a high content (40 wt %) on atomic-metal-site (e.g., MnN 4 )-rich carbon support. MEAs with the Pt (40 wt %)/Mn–N–C cathode catalyst achieved significantly enhanced performance and durability, generating 1.41 A cm –2 at 0.7 V under HDV conditions (0.25 mgPt cm –2 and 250 kPa abs pressure) and retaining 1.20 A cm –2 after an extended and accelerated stress test up to 150,000 voltage cycles. Electron microscopy studies indicate that most fine Pt nanoparticles are retained on or/and in the carbon support covered with the ionomer throughout the catalyst layer at the end of life. During the long-term stability test, the observed electrochemical active surface area reduction and performance loss primarily result from Pt depletion in the catalyst layer due to Pt dissolution and redeposition at the interface of the cathode and membrane. Importantly, the first-principle density functional theory calculations further reveal a support entrapment effect of the Mn–N–C, in which the MnN 4 site can specifically adsorb the Pt atom and further retard the Pt dissolution and migration, therefore enhancing long-term MEA durability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Travelling wave‐based fault detection and location in a real low‐voltage DC microgrid

Abstract This paper discusses a device‐level implementation of a travelling wave (TW) protection device (PD) designed for a real low‐voltage DC microgrid. The TWPD fault detection and location algorithm is executed on a commercial digital signal processor (DSP) board, involving signal sampling at 1 MHz via the DSP board's analog‐to‐digital converter (ADC). The analogue input card measures positive pole, negative pole and pole‐to‐pole voltages at the TWPD location. Upon a successful fault detection using a second‐order high‐pass filter, the voltage data is normalised and multi‐resolution analysis (MRA) is performed on a 128‐sample buffer around the TW arrival time. MRA employs the discrete wavelet transform (DWT) to capture high‐frequency voltage patterns, and then the Parseval's energy theorem quantifies these TW characteristics by computing the energy of reconstructed wavelet coefficients. These energy values per decomposed frequency band are the basis for training a random forest classifier that predicts fault location and type. The TWPD is fully implemented and connected to a real DC microgrid in Albuquerque, NM, USA, for validation, and results are shown for field tests verifying the performance under faults.

Paruthiyil, Sajay Krishnan [Department of Electric↗

Characterization of self-magnetic pinch radiographic diode performance on RITS-6 at Sandia National Laboratories. II. Coupling between the inductive voltage adder and the SMP load

The self-magnetic pinch (SMP) diode is a type of radiographic diode used to generate an intense electron beam for radiographic applications. At Sandia National Laboratories, SMP was the diode load for the six-cavity radiographic integrated test stand inductive voltage adder (IVA) driver operated in a magnetically insulated transmission line (MITL). The MITL contributes a flow current in addition to the current generated within the diode itself. Extensive experiments with a MITL of 40Ω load impedance [T. J. Renk et al., Phys. Plasmas 29, 023105 (2022)] indicate that the additional flow current leads to results similar to what might be expected from a conventional high-voltage interface driver, where flow current is not present. However, when the MITL flow impedance was increased to 80 Ω, qualitatively different diode behavior was observed. This includes large retrapping waves suggestive of an initial coupling to low impedance as well as diode current decreasing with time even as the total current does not. A key observation is that the driver generates total current (flow + diode) consistent with the flow impedance of the MITL used. The case is made in this paper that the 80Ω MITL experiments detailed here can only be understood when the IVA-MITL-SMP diode is considered as a total system. Additionally, the constraint of fixed total current plus the relatively high flow impedance limits the ability of the diode (whether SMP or other type) to act as an independent load. An unexpected new result is that in tracking the behavior of the electron strike angle on the converter as a function of time, we observed that the conventional cIV x “Radiographic” radiation scaling (where x~2.2) begins to break down for voltages above 8 MV, and cubic scaling is required to recover accurate angle tracking.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AIDA: A 16-channel amplifier ASIC to read out the advanced implantation detector array for experiments in nuclear decay spectroscopy

We have designed a read-out ASIC for nuclear decay spectroscopy as part of the AIDA project - the Advanced Implantation Detector Array. AIDA will be installed in experiments at the Facility for Antiproton and Ion Research in GSI, Darmstadt. The AIDA ASIC will measure the signals when unstable nuclei are implanted into the detector, followed by the much smaller signals when the nuclei subsequently decay. Implant energies can be as high as 20 GeV; decay products need to be measured down to 25 keV within just a few microseconds of the initial implants. The ASIC uses two amplifiers per detector channel, one covering the 20 GeV dynamic range, the other selectable over a 20 MeV or 1 GeV range. The amplifiers are linked together by bypass transistors which are normally switched off. The arrival of a large signal causes saturation of the low-energy amplifier and a fluctuation of the input voltage, which activates the link to the high-energy amplifier. The bypass transistors switch on and the input charge is integrated by the high-energy amplifier. The signal is shaped and stored by a peak-hold, then read out on a multiplexed output. Control logic resets the amplifiers and bypass circuit, allowing the low-energy amplifier to measure the subsequent decay signal. We present simulations and test results, demonstrating the AIDA ASIC operation over a wide range of input signals. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗