Search NASA⌕ Search

SEARCH · Search NASA

Results for “IP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Acoustic Monitor for Particle Size and Bed Friction in a Carbonate Fluidized Bed at High Temperature - 18014

Previous work has shown that acoustic spectra of fluidized bed pressure fluctuations show many useful bed properties [1-3]. This current work further explores the use of acoustic monitors for an 18' diameter, 66-74'' height fluidized bed at >640 deg. C. This process denitrates and agglomerates an injected sodium/aluminum nitrate aqueous simulant and produces at steady-state a denitrated product of 200-300 micron sodium carbonate/aluminate particles. The fluidized bed shows characteristic acoustic resonances around 1-2 Hz in the FFT (Fast Fourier Transform) of pressure fluctuations for each of three taps at fluidized bed heights of 12'', 39'', and 58''. The acoustic resonance spectra depend on a bed friction that once calibrated, monitors the HMPD (harmonic mass mean particle diameter or Sauter mean diameter) along with other important bed properties. This fluidized bed operates at high temperature with an evolving HMPD that can be steady state with an appropriate superficial spatial velocity (SSV). The acoustic FFT integrated power spectrum, IPS, of pressure fluctuations represents the bed-friction damped RMS (root mean square) pressure fluctuations at each tap. The transition from a static to fluidized bed at each bed height occurs when the damped bed RMS pressure fluctuations are greater than the static head (the FFT zero Hz designated zero Hz proportional to FFT zero Hz) at that bed height. A bed will de-fluidize and become static at a bed height when bed friction completely dampens the RMS pressure fluctuations, which occurs for decreasing particle size among other factors. The ratio IPS/zero Hz then provides a continuous monitor of bed friction damping as well as particle size as the HMPD. Since HMPD and bed friction damping are both very important parameters for fluidized particle beds, the acoustic HMPD and bed friction damping both provide very useful monitors for fluidized bed operation. Such acoustic monitors have shown that they are especially sensitive to the presence of very fine particles in the bed of less than 50 microns diameter. Acoustic monitors for particle size and bed friction damping will be very useful in any fluidized bed, especially fluidized beds where particle size changes. The fluidized bed friction damping depends on many other bed properties besides particle size such as bed height, density, SSV, void fraction, gas viscosity, and fluidization scheme and so acoustic bed friction should also be useful for monitoring other bed properties besides particle size. In fact, the change in the static bed friction slope with SSV upon fluidization follows the Ergun function and reveals a minimum fluidization velocity for each HMPD. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The SD-20K, a large Type B(U)F Package for Waste Containers - 18181

The type B(U)F package SD-20K, currently being developed by DAHER Nuclear Technologies GmbH (DNT), will facilitate the transport of legacy waste from interim storage facilities to the German final repository Konrad. The package SD-20K could also be used in other cases where legacy packages are not fit for a final repository and/or for transport but could be easily conditioned into a suitable package. Since the 1990's German utilities, reactor operators and service providers conditioned waste according to the requirements of the preliminary acceptance criteria for the final repository Konrad. Some of this waste was conditioned in containers which were at that time licensed as type B packages but for which the license expired due to various reasons. Other waste was reclassified so that the used package type does no longer comply with the content. In recent times Konrad containers of type IP-2 are loaded with e. g. core components in compliance with the Konrad acceptance criteria but overloaded with respect to the transport regulations. DAHER Nuclear Technologies GmbH (DNT) in cooperation with Siemens AG investigated possible solutions in a general approach. The result of the evaluation was that the best solution for the transport problem was to develop a versatile type B(U)F package large enough to accommodate all containers and packages accepted for the final repository Konrad. Possible solutions like repacking (high costs and high dose exposure) or requalification (high costs and risk of failure to achieve the goal) were not considered to be generally applicable. The SD-20K packaging is currently designed to accommodate Konrad Containers type III, IV and VI; however, the dimensions of its cavity are sufficient to accommodate any container and package that meets the acceptance criteria for the final repository Konrad. The SD-20K packaging consists of an inner container which constitutes the containment, surrounded by a rather large shock absorbing structure which also contains the thermal protection system. The outer shape of the SD-20K resembles a 20' ISO container. A special feature of the SD-20K is the automatic unloading system to minimize dose exposure of the personnel in the final repository. After arrival in the repository the shock absorbing structure as well as the door of the containment system are opened automatically and the content is moved out of the SD-20K by a remote-controlled carrier system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Challenges, Successes, and Lessons Learned on Two Active DOE Facility D and D Projects - 18379

'Surgical removal', although having a number of technical and safety challenges, is an effective alternative to traditional Demolition and Decommissioning (D and D) methods. When carefully planned and managed, surgical removal of equipment can be safely performed to achieve cost savings and accelerated schedule. At Fernald, a large groundwater extraction system that treats radionuclides was downsized during continued operations. Challenges included demolition of remedial components in tight spaces adjacent to active components, in-situ management and removal of slurry multimedia and resins, and complex hoisting/rigging of whole vessels from very tight areas. The approach realized a significant reduction in waste volumes and slurry transfer to reduce radionuclide exposure while allowing use of existing vessels as IP-1 shipping containers while providing an opportunity to implement out of the box design for hoisting/rigging/moving large vessels. Several lessons were learned as Los Alamos Technical Associates, Inc. (LATA) faced the project challenges and progressed through the D and D process. The slurry removal required thorough understanding of equipment selection and circulation techniques to maintain a slurry while avoiding plugging of extraction equipment. The physical condition of each individual tank was different and required development of alternate removal techniques, such as draining the vessel and removal of the hard material with an air vacuum truck, for each one. Lessons learned regarding large tank removal focused on recertification of an overhead crane, determination of pick points from a partially filled vessel, reanalyzing the lifting lugs for a partially full tank, and requirements to fill all void space in the vessels to meet off-site disposal specifications. At Oak Ridge National Laboratory (ORNL), LATA performed the surgical removal of all biomass process equipment inside ORNL's Building 2719. Among the challenges was a requirement that the removal action had to be conducted during continued operations. Live steam lines, fire protection, water process and boiler feed water systems were operational during LATA's D and D effort and were in close proximity to removal operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Angle Remediation Antimony, Mercury, and Pu-239/240 Contaminated Soil at LANL near Los Alamos Town Site - 18579

The Manhattan Project and early Cold War era operations at Los Alamos National Laboratory (LANL) left behind soil contaminated with antimony, mercury, and Pu-239/240. TerranearPMC (TPMC) successfully completed a phased three-year high-angle legacy cleanup project to excavate contaminated soil from a steep, difficult-to-access canyon wall in the Upper Los Alamos Canyon Aggregate Area bordering Los Alamos town site. The first and third phases of the project (years 2015 and 2017) utilized a Menzi Muck (spider excavator) in concert with a 275 US ton telescoping crane to remove ∼158 cubic yards (cy) of mercury-contaminated rock and soil (i.e. media) from one solid waste management unit (SWMU) in 2015; and ∼70 cy of antimony contaminated media, and ∼65 cy of collocated mercury and Pu-239/240 contaminated media from two SWMUs in 2017. All soil excavated from the site was containerized in soft-sided 1.0 cy, 1.77 cy, and 3.5 cy IP-1 containers and shipped to an approved, licensed, off-site disposal facility. The crane was also used to move the spider excavator, field personnel, tools, the packaged waste, and restoration materials into and out of the canyon. In 2016, conventional but miniaturized excavation equipment was used to remove about 133 cy of Pu-239/240 contaminated media from four SWMUs west of both the 2015 and 2017 excavations. A total of 398 soil screening, waste composite, characterization/bounding, and confirmation samples were collected during the project. Media that was left in place after the excavation was sampled to confirm that human health concerns and environmental risk issues had been mitigated. This proven technical approach was the preferred method for cleaning up ∼426 cy of contaminated media from steep, difficult-to-access legacy waste sites within the Upper Los Alamos Canyon Aggregate Area between 2015 and 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Authentication Protocol for ICS without Encryption

Industrial control systems (ICS) describes the different types of control systems and associated instrumentation, which includes the devices, systems, networks, and controls used to operate and/or automate industrial processes. Depending on the industry, each ICS functions differently and are built to electronically manage tasks efficiently. Historically, industrial plants have included networking, and changes have been made over time without consideration for security. Many ICS devices currently have inadequate security features. Adding encryption in ICS is undesirable because many of the new detection method involves deep packet inspection. Therefore, we propose to develop a method of providing authentication between devices without encrypting the data. This testbed design will allow rapid development and experimentation with Cyber Physical Systems. Modbus connects to a supervisory computer with a Remote Terminal Unit (RTU) in Supervisory Control and Data Acquisition (SCADA) systems. Our project seeks to enhance security in the ICS environment by adding device authentication to the lower levels of the plant floor. This approach was selected as it allows verification of the sender of data from level 1/level 0 devices up to supervisory systems. This addition is desirable as it adds enhanced verification to the integrity of system data without obscuring (via encryption) the data being transmitted across the network. This is important because many ICS systems are real time critical (decryption adds to latency) and many other good security options require deep packet inspection (which encryption completely defeats). To accomplish this, a proof of concept of adding an authentication scheme was designed and will be tested with a common ICS protocol. The setup includes a single serial cable connecting the serial ports on two devices, a Master and a Minion. Authentication will occur in the following methods: - Data layer involving Transport Layer Security/Secure Socket Layer (TLS/SSL); - TCP/IP route implementation; - Key exchange algorithm; - Raspberry Pi programming for authentication. A portion of the setup includes adding Raspberry Pi into the system as the device is handling the authentication for the network traffic. Modbus is the chosen ICS protocol. It is used to transmit signals from instrumentation and control devices back to a main controller or data gathering system. Typically, the device identity is assumed but not verified. For verifying device identity, we constructed a digital signature architecture with TLS. A novel adaptation of this is to use only the digital signature that is provided and not the encryption capability. This allows ICS traffic to flow unobscured while still providing verification for the integrity of the data. Verification of this process will involve adding additional I/O level network devices with spoofed IP addresses and detecting the authenticated versus unauthenticated traffic. Our TLS implementation will have encryption disabled but should still allow for digital signing of data. This will enable our system to distinguish between real end devices and spoofed end devices. This experiment is presently building the test setup. It is focusing on a small setting to identify authenticated and unauthenticated devices on the network. This should allow for scaling to a larger network size after the initial proof of concept. One concern with this scheme is a certificate deployment has a large scale key management. Network size will thus increase the key management task for security. In addition, we believe that further research should be done on exploring the use of this method to defeat man-in-the-middle attacks.

42 ENGINEERING↗

Qualified display system architecture - 246

There is a need in the nuclear industry for a Qualified Display System (QDS) architecture as described in this paper. The function of the QDS is to process and display Regulatory Guide 1.97 post accident monitoring parameters. The QDS is implemented on the Lockheed Martin Field-Programmable Gate Array (FPGA) based Nuclear Protection and Control (NuPAC) digital platform, coupled with a Qualified Display Controller (QDC) and a Safety Display Unit (SDU). The QDS is designed to meet the requirements of IEEE 603-1991 (endorsed by Regulatory Guide 1.153, Rev. 1), IEEE 497-2002 (endorsed by Regulatory Guide 1.97, Rev. 4), and IEEE 7-4.3.2- 2003 (endorsed by Regulatory Guide 1.152, Rev. 3). The QDS is designed with flexibility such that it can be implemented in an advanced reactor design, Small Modular Reactor (SMR) with any cooling medium, or digital upgrade project for an operating nuclear plant. The QDS has four independent and redundant divisions. Each division has five layers in the architecture: Process variable input signals; Process Protection Logic (PPL); Algorithm Logic (AL), Interface Panel (IP); and Safety Display Unit (SDU). The QDS meets the following design criteria: redundancy, independence, predictability and repeatability, and diversity capability. The QDS architecture also meets the simplicity design principle. The QDS architecture design provides flexibility in the implementation in a plant. The QDS can be implemented in the design of a new advanced plant or as a digital upgrade in an operating plant. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Implementing a control application on an FPGA Platform - 356

Today, many I and C system suppliers propose FPGA-based I and C platforms. In that context, EDF has set up a project to assess the use of such platforms for safety-related systems and to enhance EDF's ability to manage this technology for the upgrade of existing I and C systems or for new constructions. One aim of the project is to assess the adequacy of these platforms for the development of control functions. This paper presents the development of a case study on a Radiy FPGA-based platform in a Hardware-In-the-Loop configuration, and the comparison with a Dymola Model-In-the-Loop and a Siemens T2000 S7 Hardware-In-the-Loop approach. The case study is a part of the level control of steam generators of French PWR NPP. The control flow diagram uses complex analog elementary blocks coded with fixed point format for the analog values. The use of IP cores of the FPGA supplier was avoided to enable a complete mastership of the VHDL code, to provide evidence of compliance with safety-related requirements, and to allow porting this code to another FPGA platform. The case study has highlighted the specificity of using a FPGA, and has shown that a complex control application in a FPGA-based PLC presents no major differences in precision and response time with a processor-based PLC. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Electromagnetic Transient and Three-Phase Phasor Co-Simulation Platform for Studying Distribution System Transients with High Pentration of DERs

Inverter vendors usually have electro-magnetic transient (EMT) models of distributed energy resources (DERs) for validation purposes and these types of models are usually black-boxed considering intellectual property (IP) protection. Limited by small simulation time step for the entire power system network, studying the system-level responses of DERs in EMT simulators is more time-consuming as the network size increases. Meanwhile, vendors usually do not have inverter models that can be used in three-phase phasor-domain simulators. This paper proposes a platform that can dynamically co-simulate the EMT inverter models and three-phase phasor-domain distribution networks considering high penetration of inverter-based DERs. This platform is very useful for evaluating the impacts of vendor-provided black-box DER model on distribution system dynamics. The co-simulation platform is validated against the full EMT model using a simple two-inverter test system and tested using IEEE 34-node test feeder.

Liu, Yuan↗

Validating Mixtures of 233 U, 235 U, and 239 Pu for the Sum-of-Fractions Method

The Sum-of-Fractions method is a technique used to assure that homogeneous mixtures of fissile and fissionable isotopes are below a minimum margin of k eff or reactivity. Current work by Pacific Northwest National Laboratory examines different mixtures of 233 U, 235 U, and 239 Pu to determine critical mass limits for mixtures of transuranic actinides lacking a validation basis. To provide a validation basis for these limits, the work presented here describes the results of a sensitivity and uncertainty analysis of various mixtures of these isotopes in various concentrations moderated and reflected by light water and polyethylene. The TSUNAMI-1D sequence in the SCALE code system was used to generate sensitivity coefficients for three different concentrations of mixtures of 233 U, 235 U, and 239 Pu. The TSUNAMI-IP sequence was then used for similarity assessment (c k ) with critical benchmark experiment sensitivity data files (SDFs) from the Oak Ridge National Laboratory Verified, Archived Library of Inputs and Data and the Nuclear Energy Agency SDF database. The VADER sequence in SCALE was used for statistical testing and to generate upper subcritical limits from the data to develop a basis for validating critical mass limits.

07 ISOTOPE AND RADIATION SOURCES↗

Diii-D Research Advancing The Physics Basis For Optimizing The Tokamak Approach To Fusion Energy

DIII-D physics research addresses critical challenges for operation of ITER and the next generation of fusion energy devices. This is done through a focus on innovations to provide solutions for high performance long pulse operation, coupled with fundamental plasma physics understanding and model validation, to drive scenario development by integrating high performance core and boundary plasmas. Substantial increases in off-axis current drive efficiency from an innovative top launch system for EC power, and in pressure broadening for Alfven eigenmode control from a co-/counter-Ip steerable off-axis neutral beam, all improve the prospects for optimization of future long pulse/steady state high performance tokamak operation. Fundamental studies into the modes that drive the evolution of the pedestal pressure profile and electron vs. ion heat flux validate predictive models of pedestal recovery after ELMs. Understanding the physics mechanisms of ELM control and density pumpout by 3D magnetic perturbation fields leads to confident predictions for ITER and future devices. Validated modeling of high-Z shattered pellet injection for disruption mitigation, runaway electron dissipation, and techniques for disruption prediction and avoidance including machine learning, give confidence in handling disruptivity for future devices. With this physics understanding and suite of actuators, a high poloidal beta optimized-core scenario with an internal transport barrier that projects nearly to Q=10 in ITER at 9 MA was coupled to a detached divertor, and a near Super H-mode optimized-pedestal scenario with co-Ip beam injection, was coupled to a radiative divertor. The Hybrid core scenario was achieved directly, without the need for internal flux pumping, using off-axis current drive actuators, and a controller to avoid mode locking and disruptions in the ITER baseline scenario, based on plasma response to probing 3D fields, was demonstrated. Finally innovative tokamak operation using a negative triangularity shape showed many attractive features for future pilot plant operation.

Fenstermacher, M.↗

Improving Cyber Situational Understanding

Effective cybersecurity operations require the ability to analyze large amounts of information to assess security risks and formulate defensive strategies against adversaries. This has become more complex in recent years as the sprawl and interconnectivity of devices grows through implementation of virtualization, cloud computing, and Internet of Things (IoT). The amount of data and analysis required for effective cybersecurity command and control decisions far exceeds humans’ capacity to perform manually. We characterize the analysis problem as cyber situational understanding. The research presented to improve cyber situational understanding focuses on vulnerability analysis and threat intelligence. Regarding vulnerabilities, entities must analyze and plan work for between thousands and tens of thousands of software vulnerabilities annually. Entities heavily use network firewalls to limit vulnerability exposure. As a result, some of these vulnerabilities permit exposure to adversarial exploitation, whereas others are inaccessible and therefore present negligible risk of exploitation. Distinguishing between high and low risk software vulnerabilities requires a deep understanding of the vulnerability, network firewall protection, and characteristics of the targeted device. This problem is solved by extracting network service features from vulnerability data features using both machine-learning and natural language processing. Then, the network firewall topology is parsed to determine which vulnerabilities are reachable by adversaries. Ultimately, a state-based safety analysis ascertains which vulnerabilities are unsafe. A related vulnerability analysis problem occurs in cybersecurity operations when associating an entity’s hardware and software assets to public vulnerability databases. Assets often reveal hardware and software through installation artifacts and network service identification, and entities store these artifacts in inventory databases. However, software and hardware vendors apply a standard Common Platform Enumeration (CPE) naming convention when publicly reporting vulnerabilities. Associating these two datasets often requires many hours to days of manual inspection. The proposed solution automates the mapping approach of human analysts using fuzzy matching techniques, natural language processing, and, ultimately, machine learning to present a small set of recommendations for mapping the two datasets. The result significantly reduces human analysis time and reduces the occurrence of false positives in vulnerability notifications. Finally, cyber threat intelligence (CTI) requires associating cyber observable artifacts, such as IP addresses, URIs, and file hashes, with cyber threat tactics, techniques, and procedures. Unfortunately, most CTI data is compartmentalized across multiple organizations and cannot be shared due to the legal and reputational risk with cyber threat being associated with the entity. The approach to solving this problem inovlves using a distributed ledger with anonymous token spending and authentication. This allows a consortium of semi-trusted entities to share the workload of curating CTI for a threat sharing community’s cooperative benefit.

Huff, Philip↗

Improving LER Coupling and PEP-II Luminosity with Model-Independent Analysis

The PEP-II storage ring at SLAC houses electrons (in the High-Energy Ring, or HER) and positrons (in the Low-Energy Ring, or LER) for collision. The goal of this project was to improve the linear optics of the LER in order to decrease coupling, thereby decreasing emittance and increasing luminosity. To do this, we first took turn by turn BPM (Beam Position Monitor) data of a single positron bunch at two betatron resonance excitations, extracted orbits from this data using Model-Independent Analysis, and from these orbits formed a virtual model of the accelerator. We then took this virtual model and found an accelerator configuration which we predicted would, by creating vertical symmetric sextupole bumps and adjusting the strengths of several key quadrupole magnets, improve the coupling and decrease the emittance in the LER. We dialed this configuration into the LER and observed the coupling, emittance, and luminosity. Coupling immediately improved, as predicted, and the y emittance dropped by a dramatic 40%. After the HER was adjusted to match the LER at the Interaction Point (IP), we saw a 10% increase in luminosity, from 10.2 x 10{sup 33}cm{sup -2}sec{sup -1} to 11.2 x 10{sup 33}cm{sup -2}sec{sup -1}, and achieved a record peak specific luminosity.

43 PARTICLE ACCELERATORS↗

Interaction Region Upgrades of e+ e- B-Factories

Both the PEP-II and KEKB B-Factories have plans to upgrade their Interaction Regions (IRs) in order to improve luminosity performance. Last summer PEP-II added cooling to the IR beam pipe in order to increase beam currents thereby raising the luminosity. In addition, PEP-II is working on a design that modifies the permanent magnets near the Interaction Point (IP) for an even higher luminosity increase. KEKB is also planning an improvement to their IR that will decrease the detector beam pipe radius. In addition, KEK has a design to increase the luminosity of KEKB to 1 x 10{sup 35} cm{sup -2} sec{sup -1} which includes changes to the IR. PEP-II is also investigating the feasibility of a 1 x 10{sup 36} cm{sup -2} sec{sup -1} luminosity design. I summarize these various upgrades and concentrate on issues common to the different designs.

43 PARTICLE ACCELERATORS↗

A Flight Simulator for ATF2 - A Mechanism for International Collaboration in the Writing and Deployment of Online Beam Dynamics Algorithms

The goals of ATF2 are to test a novel compact final focus optics design with local chromaticity correction intended for use in future linear colliders. The newly designed extraction line and final focus system will be used to produce a 37nm vertical waist from an extracted beam from the ATF ring of {approx}30nm vertical normalized emittance, and to stabilize it at the IP-waist to the {approx}2nm level. Static and dynamic tolerances on all accelerator components are very tight; the achievement of the ATF2 goals is reliant on the application of multiple high-level beam dynamics control algorithms to align and tune the electron beam in the extraction line and final focus system. Much algorithmic development work has been done in Japan and by colleagues in collaborating nations in North America and Europe. We describe here development work towards realizing a 'flight simulator' environment for the shared development and implementation of beam dynamics code. This software exists as a 'middle-layer' between the lower-level control systems (EPICS and V-SYSTEM) and the multiple higher-level beam dynamics modeling tools in use by the three regions (SAD, Lucretia, PLACET, MAD...).

43 PARTICLE ACCELERATORS↗

Experience with IBS-suppression lattice in RHIC

An intra-beam scattering (IBS) is the limiting factor of the luminosity lifetime for RHIC operating with heavy ions. In order to suppress the IBS we designed and implemented new lattice with higher betatron tunes. This lattice had been developed during last three years and had been used for gold ions in yellow ring of the RHIC during d-Au part of the RHIC Run-8. The use of this lattice allowed both significant increases in the luminosity lifetime and the luminosity levels via reduction of beta-stars in the IPS. In this paper we report on the development, the tests and the performance of IBS-suppression lattice in RHIC, including the resulting increases in the peak and the average luminosity. We also report on our plans for future steps with the IBS suppression.

43 PARTICLE ACCELERATORS↗

Numerical Prediction of the Performance of Integrated Planar Solid-Oxide Fuel Cells, with Comparisons of Results from Several Codes

A numerical study of the thermal and electrochemical performance of a single-tube Integrated Planar Solid Oxide Fuel Cell (IP-SOFC) has been performed. Results obtained from two finite-volume computational fluid dynamics (CFD) codes FLUENT and SOHAB and from a two-dimensional inhouse developed finite-volume GENOA model are presented and compared. Each tool uses physical and geometric models of differing complexity and comparisons are made to assess their relative merits. Several single-tube simulations were run using each code over a range of operating conditions. The results include polarization curves, distributions of local current density, composition and temperature. Comparisons of these results are discussed, along with their relationship to the respective imbedded phenomenological models for activation losses, fluid flow and mass transport in porous media. In general, agreement between the codes was within 15% for overall parameters such as operating voltage and maximum temperature. The CFD results clearly show the effects of internal structure on the distributions of gas flows and related quantities within the electrochemical cells.

08 HYDROGEN↗

Copper Prototype Measurements of the HOM, LOM and SOM Couplers for the ILC Crab Cavity

The ILC Crab Cavity is positioned close to the IP and delivered luminosity is very sensitive to the wakefields induced in it by the beam. A set of couplers were designed to couple to and damp the spurious modes of the crab cavity. As the crab cavity operates using a dipole mode, it has different damping requirements from an accelerating cavity. A separate coupler is required for the monopole modes below the operating frequency of 3.9 GHz (known as the LOMs), the opposite polarization of the operating mode (the SOM), and the modes above the operating frequency (the HOMs). Prototypes of each of these couplers have been manufactured out of copper and measured attached to an aluminum nine cell prototype of the cavity and their external Q factors were measured. The results were found to agree well with numerical simulations.

43 PARTICLE ACCELERATORS↗