Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

The Global Threat Reduction Initiative's Orphan Source Recovery Project in the Russian Federation

After 9/11, officials at the United States Department of Energy (DOE), National Nuclear Security Administration (NNSA) grew more concerned about radiological materials that were vulnerable to theft and illicit use around the world. The concern was that terrorists could combine stolen radiological materials with explosives to build and detonate a radiological dispersal device (RDD), more commonly known as a “dirty bomb.” In response to this and other terrorist threats, the DOE/NNSA formed what is now known as the Global Threat Reduction Initiative (GTRI) to consolidate and accelerate efforts to reduce and protect vulnerable nuclear and radiological materials located at civilian sites worldwide. Although a cooperative program was already underway in the Russian Federation to secure nuclear materials at a range of different facilities, thousands of sealed radioactive sources remained vulnerable at medical, research, and industrial sites. In response, GTRI began to focus efforts on addressing these materials. GTRI’s Russia Orphan Source Recovery Project, managed at the Nevada National Security Site’s North Las Vegas facility, was initiated in 2002. Throughout the life of the project, Joint Stock Company “Isotope” has served as the primary Russian subcontractor, and the organization has proven to be a successful partner. Since the first orphan source recovery of an industrial cobalt-60 irradiator with 647 curies (Ci) at an abandoned facility in Moscow in 2003, the GTRI Orphan Source Recovery Project in the Russian Federation has accomplished substantial levels of threat reduction. To date, GTRI has recovered and securely disposed of more than 5,100 sources totaling more that 628,000 Ci. This project serves as an extraordinary example of how international cooperation can be implemented by partners with mutual interests to achieve significant goals.

GTRI, Global Threat Reduction Initiative, Russian ↗

TU-FG-201-10: Quality Management of Accelerated Partial Breast Irradiation (APBI) Plans

Purpose: Since 2008, over 700 patients received high dose rate (HDR) APBI treatment at Virginia Hospital Center. The complexity involved in the planning process demonstrated a broad variation between patient geometry across all applicators, in relation to anatomical regions of interest. A quality management program instituting various metrics was implemented in March 2013 with the goal of ensuring an optimal plan is achieved for each patient. Methods: For each plan, an in-house complexity index, geometric conformity index, and plan quality index were defined. These indices were obtained for all patients treated. For patients treated after the implementation, the conformity index and quality index were maximized while other dosimetric limits, such as maximum skin and rib doses, were strictly kept. Subsequently, all evaluation parameters and applicator information were placed in a database for cross-evaluation with similar complexity. Results: Both the conformity and quality indices show good correlation with the complexity index. They decrease as complexity increases for all applicators. Multi lumen type balloon applicators demonstrate a minimal advantage over single lumen applicators in increasingly complex patient geometries, as compared to SAVI applicators which showed considerably greater advantage in these circumstances. After the implementation of the in-house planning protocol, there is a direct improvement of quality for SAVI plans. Conclusion: Due to their interstitial nature, SAVI devices show a better conformity in comparison to balloon-based devices regardless of the number of lumens, especially in complex cases. The quality management program focuses on optimizing indices by utilizing prior planning knowledge based on complexity levels. The database of indices assists in decision making and has subsequently aided in balancing the experience level among planners. This approach has made APBI planning more robust for patient care, with a measurable improvement in the plan quality.

60 APPLIED LIFE SCIENCES↗

Calibration of passive remote observing optical and microwave instrumentation; Proceedings of the Meeting, Orlando, FL, Apr. 3-5, 1991

Various papers on the calibration of passive remote observing optical and microwave instrumentation are presented. Individual topics addressed include: on-board calibration device for a wide field-of-view instrument, calibration for the medium-resolution imaging spectrometer, cryogenic radiometers and intensity-stabilized lasers for EOS radiometric calibrations, radiometric stability of the Shuttle-borne solar backscatter ultraviolet spectrometer, ratioing radiometer for use with a solar diffuser, requirements of a solar diffuser and measurements of some candidate materials, reflectance stability analysis of Spectralon diffuse calibration panels, stray light effects on calibrations using a solar diffuser, radiometric calibration of SPOT 23 HRVs, surface and aerosol models for use in radiative transfer codes. Also addressed are: calibrated intercepts for solar radiometers used in remote sensor calibration, radiometric calibration of an airborne multispectral scanner, in-flight calibration of a helicopter-mounted Daedalus multispectral scanner, technique for improving the calibration of large-area sphere sources, remote colorimetry and its applications, spatial sampling errors for a satellite-borne scanning radiometer, calibration of EOS multispectral imaging sensors and solar irradiance variability.

Guenther, Bruce W.↗

Chemical and Radiological Compatibility Testing of 3D Printed Materials

To dramatically increase the adaptability, performance, and safety of processes in support of the Defense Waste Processing Facility (DWPF), Savannah River National Lab (SRNL) plans to perform chemical and radiological compatibility testing on a wide variety of 3D printed materials of interest. The 3D printing process provides numerous strategic operational benefits such as rapid prototyping of complex designs and geometry specific to the needs of the nuclear waste disposition process, as well as on-demand rapid prototyping and iteration with materials that aren’t as accessible through traditional manufacturing methods. Reaction chemistry in simulated waste batches can be matched closely to its radioactive counterpart, but glass reactor vessels have limitations. Vessel geometry can play a big factor in mixing transport limitations, process chemistry, and degradation reaction kinetics. In addition, additive manufacturing allows for much more detailed vessel design than traditional alternatives. Waste processing techniques in DWPF also encounter extreme chemical environments including high pH, strong acids, abrasive slurries, and significant irradiation. To meet these challenges, a matrix of various polymer, ceramic, and metal additive manufacturing materials have been exposed to a suite of chemical environments of interest as well as radioactive dose (such as gamma radiation from 60 Co) to properly test their durability under these conditions. Mass change has been monitored over a period of up to a week in these conditions, as well as added characterization for surface modification through Scanning Electron Microscopy/Electron Dispersive X-ray analysis (SEM/EDX). Further chemical characterization has been monitored through Fourier-Transform InfraRed Spectroscopy (FTIR), with planned investigation via thermal and tensile strength degradation. While the direct product of this research is identification of material(s) that can withstand specific hazardous environments encountered by the mercury water wash tank in DWPF process simulation experiments, the reference base of materials will be used for many other nuclear processes in the pursuit of rapidly developed, cost-efficient, and highly specific devices for environmental remediation and much more.

Wilson, Nathan W. [Savannah River National Laborat↗

Tuning of electrical charging effects for ferromagnetic Mn-doped ZnO nanocrystals embedded into a SiO{sub 2} layer fabricated by KrF excimer laser irradiation

The ZnMnO nanocrystals were formed by the laser irradiation of the sputter-deposited ZnMnO ultrathin layer using a 248 nm KrF excimer laser, and the size and density of the nanocrystals were observed to be controllable by modulations of either the energy density or the frequency of the irradiated pulsed-laser beam. Metal-oxide-semiconductor capacitors fabricated using ZnMnO nanocrystals clearly showed the electrical charging effect, and it was observed that the memory window depends on the size and density of nanocrystals. For measurements of the spontaneous magnetization, ZnMnO nanocrystals showed to have room-temperature ferromagnetism with M{sub r} of approx1.5 emu/cm{sup 3} and H{sub c} 167 Oe. By using ferromagnetism in ZnMnO nanocrystals, tuning of the memory window was demonstrated. Namely, it was clearly observed that the flat-band voltage shift of approx1.25 V can be modulated to be approx0.8 V by applying the magnetic field. This is attributed to the modulation of probabilities for tunneling events due to the increased magnetoelectrical repulsion between spin-polarized carriers in ZnMnO dilute magnetic semiconductor nanocrystals and unpolarized carriers in p-Si under the magnetic field. These results suggest that ZnMnO nanocrystals can be used for spin-functional memory devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Search for TiO and Optical Nightside Emission from the Exoplanet WASP-33b

With a temperature akin to an M dwarf, WASP-33b is among the hottest Jupiters known, making it an ideal target for high-resolution optical spectroscopy. By analyzing both transmission and emission spectra, we aim to substantiate previous reports of atmospheric TiO and a thermal inversion within the planet’s atmosphere. We observed two transits and six arcs of the phase curve with the Echelle SpectroPolarimetric Device for the Observation of Stars (ESPaDOnS) on the Canada–France–Hawaii Telescope and High Resolution Echelle Spectrometer (HIRES) on the Keck telescope, which provide high spectral resolution and ample wavelength coverage. We employ the Doppler cross-correlation technique to search for the molecular signatures of TiO and H{sub 2}O in these spectra, using models based on the TiO line list of Plez. Though we cannot exclude line-list-dependent effects, our data do not corroborate previous indications of a thermal inversion. Instead we place a 3σ upper limit of 10{sup −9} on the volume mixing ratio of TiO for the T–P profile we consider. While we are unable to constrain the volume mixing ratio of water, our strongest constraint on TiO comes from dayside emission spectra. This apparent absence of a stratosphere sits in stark contrast to previous observations of WASP-33b as well as theoretical predictions for the atmospheres of highly irradiated planets. The discrepancy could be due to variances between line lists, and we stress that detection limits are only as good as the line list employed, and are only valid for the specific T–P profile considered due to the strong degeneracy between lapse rate (dT/dlogP) and molecular abundance.

79 ASTRONOMY AND ASTROPHYSICS↗

Surrogate Post-Detonation Urban Debris (SPUD): Standard Reference Materials 4600 and 4601

If a terrorist nuclear explosion were to occur in the United States, high-quality (accurate and precise) legally defensible nuclear forensics measurements will be required to assure the certainty and confidence needed, for conclusions drawn from these data will be coupled with law enforcement and intelligence information for the purposes of attribution and retribution. Standard Reference Materials (SRMs)/Certified Reference Materials (CRMs) establish the traceability, accuracy, and precision of nuclear forensic measurements and provide the ability to benchmark measurement methods essential to meeting the requirements of legal scrutiny. Currently there is a critical shortage of key SRMs/CRMs required for accurate and precise measurements that are fundamental to nuclear measurements supporting pre- and post-detonation nuclear forensics. Supplies either do not exist, are not good enough, are in short supply, and/or are very expensive. The radionuclide measurement techniques and data quality objectives for pre- and post-detonation nuclear forensics are quite different than the applications for which the current suite of available SRMs/CRMs was developed. Specifically, 1) modern mass spectrometry methods have largely replaced traditional activity-based measurement methods for quantifying small quantities of long-lived radionuclides and most trace radionuclide SRMs/CRMs are certified for activity and are thus not adequate for current applications, 2) modern instrumental methods are capable of higher precision than historic measurement techniques, and in some cases exceed the precision of the available SRMs/CRMs, and 3) the quality assurance requirements for pre- and post-detonation nuclear forensics are such that the existing cadre of SRMs/CRMs does not adequately support the needs for method validation. There are numerous governmental stakeholders both within the US (DOE, DoD) and internationally (IAEA, JRC-ITU) whose missions are either directly involved with nuclear forensics measurements or rely on the forensic data obtained to make the exacting policy decisions (DOJ (FBI), DHS, CIA, DIA, DoD) associated with disrupting the production of illicit nuclear materials, interdicted nuclear materials or a nuclear/radiological detonation event. Starting in 2008 the DHS NTNFC, in collaboration with NBL and NIST, took on the production of suitable SRMs/CRMs for the pre-detonation nuclear forensics community. Two CRMs have been released since the start of this effort and two more are slated for completion in 2016. More recently, NIST, as a part of its mission as the US National Metrology Institute (NMI) to deliver standards (providing traceability) and foster homeland security, has launched the first certification campaign of a measurement traceable post nuclear detonation SRM. NIST, in cooperation with partner labs (AFIT (DoD), FBI (DOJ), and NPL) and with support from the FBI, has developed two Surrogate Post-Detonation Urban Debris (SPUD) Standard Reference Materials (SRMs) - SRM 4600 and 4601. These SRMs have been developed to simulate the expected debris mixture from the detonation of an Improvised Nuclear Device (IND) in an urban environment, which is capable of producing fresh fission as well as activation products. The elemental composition of the vitrified debris materials is a composite of minerals and metals characteristic of the concrete and steel, the building materials that would be exposed to a nuclear detonation and whose resulting activation products would be found in rubble samples collected for forensics evidence and attribution. Additionally, because post-detonation samples would also contain short-lived fission products, the debris materials have been doped with Uranium (U). To create the nuclear fission products, samples of the SPUD materials can be placed in a well-characterized nuclear reactor and exposed to a set neutron flux and energy, causing the encased U atoms to split and yield short-lived fission products. Because a known amount of U is added to the SPUD materials it is feasible to determine the concentration of the resulting fission products. The subsequent irradiated SPUD glass would be chemically similar to samples that would be generated in an actual detonation, and thus can serve as a standardized reference material for nuclear forensic post detonation measurements. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Spectrum diagnoses of laser ion source at IFP

Laser ion source is a key component of induction accelerators for heavy ion fusion, and such a source is under research at Institute of Fluid Physics (IFP). In this paper, optical emission spectroscopy is used to diagnose the Cu plasma irradiated by a quadruplicated frequency Nd: YAG laser (266 nm). The spectra show that there are no highly charged ions. The results show that the electron temperature is about 1 eV and the electron density is 4.4x10{sup 16} cm{sup -3}. And the temporal spectra are measured, which indicate that the lifetime of excited state particles is over 3 μs. The temporal electron temperature is calculated, which stays the same in the most of the time during plasma expansion. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proof of principle study of the use of a CMOS active pixel sensor for proton radiography

Purpose: Proof of principle study of the use of a CMOS active pixel sensor (APS) in producing proton radiographic images using the proton beam at the Massachusetts General Hospital (MGH). Methods: A CMOS APS, previously tested for use in s-ray radiation therapy applications, was used for proton beam radiographic imaging at the MGH. Two different setups were used as a proof of principle that CMOS can be used as proton imaging device: (i) a pen with two metal screws to assess spatial resolution of the CMOS and (ii) a phantom with lung tissue, bone tissue, and water to assess tissue contrast of the CMOS. The sensor was then traversed by a double scattered monoenergetic proton beam at 117 MeV, and the energy deposition inside the detector was recorded to assess its energy response. Conventional x-ray images with similar setup at voltages of 70 kVp and proton images using commercial Gafchromic EBT 2 and Kodak X-Omat V films were also taken for comparison purposes. Results: Images were successfully acquired and compared to x-ray kVp and proton EBT2/X-Omat film images. The spatial resolution of the CMOS detector image is subjectively comparable to the EBT2 and Kodak X-Omat V film images obtained at the same object-detector distance. X-rays have apparent higher spatial resolution than the CMOS. However, further studies with different commercial films using proton beam irradiation demonstrate that the distance of the detector to the object is important to the amount of proton scatter contributing to the proton image. Proton images obtained with films at different distances from the source indicate that proton scatter significantly affects the CMOS image quality. Conclusion: Proton radiographic images were successfully acquired at MGH using a CMOS active pixel sensor detector. The CMOS demonstrated spatial resolution subjectively comparable to films at the same object-detector distance. Further work will be done in order to establish the spatial and energy resolution of the CMOS detector for protons. The development and use of CMOS in proton radiography could allow in vivo proton range checks, patient setup QA, and real-time tumor tracking.

60 APPLIED LIFE SCIENCES↗

MO-DE-210-04: Repositioning and Monitoring of Prostate Cancer Radiotherapy with a New 4D Ultrasound Intra-Modality IGRT Device

Purpose: We report our clinical experience using a non-invasive transperineal (TP) ultrasound (US) probe dedicated to pre-positioning and monitoring of prostate cancer patients. The accuracy of pre-treatment positioning was compared to CBCT for prostate and post-prostatectomy patients. Intrafraction motions were recorded for both localizations. The dosimetric impact of these displacements was finally investigated on prostate patients. Methods: Differences between CBCT/CT and TP-US/TP-US registrations were analyzed on 427 and 453 sessions for 13 prostate and 14 post-prostatectomy patients, respectively. Ten prostate patients’ dosimetries were retrospectively planned using 2 different protocols: 80Gy in 40 fractions and 36.25Gy in 5 fractions with a 5mm CTV- to- PTV margin. The delivery time was measured in order to analyze ranges of intrafraction motions related to each protocol. Mean prostate displacements were calculated for each patient and applied to the treatment isocenter coordinates to evaluate the dosimetric impact of these motions. Results: CBCT and TP-US shifts agreements at ±5mm were 76.6%, 95.1%, 96.3% and 90.3%, 85.0%, 97.6% in anterior- posterior, superior- inferior and left-right directions, for prostate and post-prostatectomy patients, respectively. Intrafraction motions were analyzed considering delivery times of 140 and 290s with an additional time of 120s for patient installation for doses of 2 and 7.25Gy, respectively. Intrafraction motions were patient-dependent and were larger as the irradiation time increased. Larger displacements were observed for prostate compared to post-prostatectomy localizations. Shifts above 3mm were observed on 17.6% and 4.5% of the 2Gy sessions against 30.6% and 7.3% of the 7.25Gy sessions in the anterior-posterior direction for prostate and post-prostatectomy localizations, respectively. Preliminary dosimetric results showed that intrafraction motions mainly impact the PTV coverage. Conclusion: 4D TP-US modality is a promising alternative to irradiating and/or invasive IGRT modalities for both inter and intrafraction motions management. Preliminary dosimetric results show that intrafraction monitoring is mandatory especially for hypofractionated treatments. M Fargier-Voiron was supported by a PhD grant from Elekta.

60 APPLIED LIFE SCIENCES↗

In-Situ Characterization Tools for Evaluating Radiation Tolerance and Elemental Migration in Perovskites

This paper discusses the in-situ characterization tools designed to assess radiation tolerance and elemental migration in perovskite materials. With the increasing use of perovskites in various technological applications, understanding their response to radiation exposure is paramount. Ion Beam Induced Charge (IBIC) emerges as a powerful tool for investigating the radiation tolerance of perovskites at the microscale. By employing focused ion beams, IBIC allows for the spatial mapping of charge carriers, offering insights into the material's electronic response to radiation-induced defects. This technique enables researchers to pinpoint areas of enhanced or suppressed charge collection, providing valuable information on the perovskite's intrinsic properties under irradiation. Rutherford Backscattering Spectrometry (RBS) complements the study by offering a quantitative analysis of elemental migration in perovskite materials. Through the precise measurement of backscattered ions, RBS provides a detailed understanding of the elemental composition and distribution within the perovskite lattice after radiation exposure. The integration of IBIC and RBS techniques in in-situ experiments enhances the comprehensive characterization of radiation effects on perovskites.

ion beams↗

Thin N-I-P radiation resistant solar cells

Several sets of N-I-P sola cells were fabricated from high resistivity silicon to test the effectiveness of various methods for hardening these devices against radiation. Different substrate materials were used to provide information on the effects of dopant concentration, silicon type, and the presence of oxygen. In some cells, P-type float-zone refined silicon of 800, 8000 and 15,000 omega-cm resistivity was used to provide a basis for studying resistivity and purity effects. In other cells, N-type silicon (approximately 800 omega-cm) was used to allow a comparison of dopant type. Oxygen-rich, crucible-grown, silicon (approximately 100 omega-cm, p-type) will provide information on purity effects and defect gettering. Lithium was introduced into different types of silicon to determine if mobile ions can reduce radiation induced defects in high resistivity material. Thin cells (2 mil) were fabricated to study the effects of cell thickness and carrier injection on radiation damage. The electrical characteristics of the different sets of cells were measured, analyzed, and compared prior to shipment of the cells to NASA/Lewis for irradiation.

Meulenberg, A.↗

Low-leakage p-type diamond Schottky diodes prepared using vacuum ultraviolet light/ozone treatment

Room-temperature fabrication of Schottky diodes was demonstrated for p-type boron-doped diamond. This fabrication method's key technique is selective modification of surface termination from monohydride into oxygen groups using vacuum ultraviolet light irradiation in oxygen. The Au contacts, formed on the hydrogen-terminated surface, maintained Ohmic properties after this selective surface oxidation. The Au contacts then deposited on the oxidized surface, imparting Schottky properties. The lateral-type diodes comprising Au Schottky contacts and Au Ohmic contacts showed blocking voltage higher than 1 kV without electrode guarding. The leakage current at 1 kV was as low as 30 pA.

36 MATERIALS SCIENCE↗

Laser radiation scattering from the wires and fibers of imploding arrays on the Angara-5-1 facility

A method is developed for measurements of laser radiation scattering by wires and fibers in different types of imploding arrays in the initial stage of plasma production at discharge currents per wire of up to 2 kA for aluminum arrays and up to 8 kA for tungsten arrays. The experiments were carried out on the Angara-5-1 facility at a current density in the wires of 10{sup 8} A/cm{sup 2} and current growth rate of {approx}10{sup 13} A/s. It is found that the indicatrix of laser radiation reflected from the wires (fibers) in cylindrical and conical arrays is modified at currents of 0.1-10 kA per wire (fiber). The experimental data on the reflection and scattering of laser radiation from wires and fibers are compared with the results of numerical simulations of their electric explosion in vacuum. It is proposed that the change in the reflection indicatrix of laser radiation is caused by the onset of thermal instabilities. The typical size of density and temperature inhomogeneities on the wire surface is in a range of 10-20 {mu}m, which probably results in a transition from specular to diffuse reflection of laser radiation. A simultaneous abrupt (over 2-3 ns) reduction in the reflection intensity from several wires of an array indicates a homogeneous distribution of the discharge current over the irradiated wires. This closes the issue of the quality of the contact between the wires and the electrodes. The obtained experimental information is of considerable importance for the development of numerical codes for simulations of the implosion of wire arrays and the refinement of the wire parameters in the initial stage of plasma production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The management of tumor motions in the stereotactic irradiation to lung cancer under the use of Abches to control active breathing

Purpose: Breathing control is crucial to ensuring the accuracy of stereotactic irradiation for lung cancer. This study monitored respiration in patients with inoperable nonsmall-cell lung cancer using a respiration-monitoring apparatus, Abches, and investigated the reproducibility of tumor position in these patients. Methods: Subjects comprised 32 patients with nonsmall-cell lung cancer who were administered stereotactic radiotherapy under breath-holding conditions monitored by Abches. Computed tomography (CT) was performed under breath-holding conditions using Abches (Abches scan) for treatment planning. A free-breathing scan was performed to determine the range of tumor motions in a given position. After the free-breathing scan, Abches scan was repeated and the tumor position thus defined was taken as the intrafraction tumor position. Abches scan was also performed just before treatment, and the tumor position thus defined was taken as the interfraction tumor position. To calculate the errors, tumor positions were compared based on Abches scan for the initial treatment plan. The error in tumor position was measured using the BrainSCAN treatment-planning device, then compared for each lung lobe. Results: Displacements in tumor position were calculated in three dimensions (i.e., superior-inferior (S-I), left-right (L-R), and anterior-posterior (A-P) dimensions) and recorded as absolute values. For the whole lung, average intrafraction tumor displacement was 1.1 mm (L-R), 1.9 mm (A-P), and 2.0 mm (S-I); the average interfraction tumor displacement was 1.1 mm (L-R), 2.1 mm (A-P), and 2.0 mm (S-I); and the average free-breathing tumor displacement was 2.3 mm (L-R), 3.5 mm (A-P), and 7.9 mm (S-I). The difference between using Abches and free breathing could be reduced from approximately 20 mm at the maximum to approximately 3 mm in the S-I direction for both intrafraction and interfraction positions in the lower lobe. In addition, maximum intrafraction tumor displacement with the use of Abches was 4.5 mm (S-I) in the lingular segment. These results suggest that use of the Abches system can reduce deviations in tumor position to levels below those achieved under free breathing, irrespective of the tumor location. Conclusions: Respiratory control with high accuracy and reproducibility is required for high-precision radiotherapy of inoperable nonsmall-cell lung cancer and was achieved using Abches in this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RaDIATE Collaboration Thermal shock studies

As next-generation accelerator target facilities (High Energy Physics, Spallation Sources, ... ) become increasingly more powerful and intense, high power target systems face key technical challenges, such as radiation damage and thermal shock. Those ultimately degrade the performance and lifetime of targets and have been identified as the leading cross-cutting challenges of high-power target facilities. In order to operate reliable beam-intercepting devices in the framework of energy and intensity increase for next generation accelerators, the RaDIATE Collaboration (Radiation Damage In Accelerator Target Environment), established in 2012 and managed by Fermilab, brings together existing expertise in nuclear material and accelerator targets from 20 international institutions, including CERN, to execute a coordinated strategy for high power targetry R&D. In this context, several thermal shock studies were performed at CERN's HiRadMat (High-Radiation to Materials) facility, that took a key step towards improving our knowledge on target damage tolerance. The first experiment HRMT-24, supported by EURCARD2 and completed in 2015, successfully validated the Johnson-Cook strength model developed at SwRI on beryllium S200FH (used for beam window material), providing a better confidence in simulating the thermal shock response of current and future S200FH beryllium components. HRMT-43, supported by ARIES and completed in 2018, tested various materials (Be, C, SiC, Si, Ti and ceramic nanofiber). It was a first and unique test which included pre-irradiated specimens from high energy proton beam irradiation to identify thermal shock response differences between non-irradiated and previously irradiated materials. Real-time measurement of dynamic thermomechanical response of graphite helped to benchmark numerical simulations.

43 PARTICLE ACCELERATORS↗

Genesis Concentrator Target Particle Contamination Mapping and Material Identification

The majority of surface particles were found to be < 5 microns in diameter with increasing numbers close to the optical resolution limit of 0.3 microns. Acceleration grid EDS results show that the majority of materials appear to be from the SRC shell and SLA materials which include carbon-carbon fibers and Si-rich microspheres in a possible silicone binder. Other major debris material from the SRC included white paint, kapton, collector array fragments, and Al. Image analysis also revealed that SRC materials were also found mixed with the Utah mud and salt deposits. The EDS analysis of the acceleration grid showed that particles < 1 m where generally carbon based particles. Chemical cleaning techniques with Xylene and HF in an ultrasonic bath are currently being investigated for removal of small particles by the Genesis science team as well as ultra-pure water megasonic cleaning by the JSC team [4]. Removal of organic contamination from target materials is also being investigated by the science team with the use of UV-ozone cleaning devices at JSC and Open University [5]. In preparation for solar wind oxygen analyses at UCLA and Open University [1, 2], surface particle contamination on three Genesis concentrator targets was closely examined to evaluate cleaning strategies. Two silicon carbide (Genesis sample # 60001 and 60003) and one chemical vapor deposited (CVD) 13C concentrator target (60002) were imaged and mosaic mapped with optical microscopes. The resulting full target mosaic images and particle feature maps were subsequently compared with non-flight, but flight-like, concentrator targets and sample return capsule (SRC) materials. Contamination found on the flown concentrator acceleration grid was further examined using a scanning electron microscope (SEM). Energy dispersive X-ray spectroscopy (EDS) for particle identification was subsequently compared with the optical images from the flown targets. Figure 1 show that all three targets imaged in this report are fully intact and do not show any signs of material fractures. However, previous ellipsometry results and overview imaging of both flown SiC targets show a solar wind irradiation gradient from the center focal point to the outer edge [3]. In addition, due to the hard landing, each target has experienced varying degrees of impacts, scratches, and particle debris from the spacecraft and Utah impact site.

Calaway, Michael J.↗

AREVA NP MR Cladding benefits for proposed US NRC RIA and LOCA requirements

M5 is the reference alloy of AREVA NP for PWR cladding applications. It is a zirconium-based alloy containing 1% niobium, no tin, and well-controlled oxygen, iron, and sulfur contents. It has a fully recrystallized microstructure. The absence of tin in M5 results in a very low corrosion rate and hydrogen pick-up during normal operation, even at high burn-up and in high duty irradiation conditions. Due to this low hydrogen pick-up under irradiation (typically less than 100 ppm, End of Life), M5 retains a very good strength and an exceptional residual ductility during and after the accident. This allows utilities implementing M5 to simplify the safety analysis and to demonstrate significant margins regarding fuel related criteria. Simplified methods are easier for plants to implement and maintain for future plant operations and core design management. This paper specifically presents 3 examples on the safety improvement brought by M5 cladding. First, during a reactivity-induced accident (RIA), the properties of M5 are such that bounding analyses for future cycles are significantly simplified, in particular by demonstrating that fuel dispersal will not occur. The major aspects of the AREVA NP RIA methodology are presented. A second focus is made on the low hydrogen embrittlement of M5 and on its high ductility after quenching during a loss-of-coolant accident (LOCA). In a third part, the breakaway oxidation testing program currently under development in Paimboeuf (France) is described, including details about the testing devices and qualification. The tests have demonstrated that M5 cladding does not have breakaway at least up to 5000 s oxidation duration at 1000 C. degrees, which is much higher than the LOCA duration.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗