Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Design and analysis of magnetic coil for relativistic magnetron

This paper presents the design of magnetic coil for relativistic magnetron (RM) for LIA (Linear Induction Accelerator)-400 systems. Vacuum improves the efficiency of RM for HPM generation. Magnetic field in RM is very critical parameter and should be nearly constant in the active region. Typical coils are helical in nature, which have multi turns of varying radius. Magnetic field calculation of such coils with basic equations of Helmholtz coils or solenoid with mean radius can only give estimation. Field computational softwares like CST require small mesh size and boundary at very far so consume large memory and take very much time. Helical coils are simplified such that the basic law of magnetic field calculation i.e. Bio-Savart law can be applied with less complexity. Pairs of spiral coils have been analyzed for magnetic field and Lorenz's force. The approach is field experimentally validated. (author)

43 PARTICLE ACCELERATORS↗

Longitudinal Emittance Measurements at PIP2IT

The PIP-II particle accelerator is a new upgrade to the Fermilab accelerator complex, featuring an 800-MeV H⁻ superconducting linear accelerator that will inject the beam into the present Fermilab Booster. A test accelerator known as PIP-II Injector Test (PIP2IT) has been built to validate the concept of the front-end of PIP-II. One of the paramount challenges of PIP2IT was to demonstrate a low longitudinal emittance at the end of the front end. Having a low longitudinal emittance is crucial in order to ensure the stability of the beam in the accelerator. We present a longitudinal emittance calculation at 14.3 MeV at the SSR1-8 cavity in the High Energy Transport line (HEBT). The signal is collected by a Fast Faraday Cup (FFC) at the end of HEBT and recorded by a high-bandwidth oscilloscope.

43 PARTICLE ACCELERATORS↗

Exploring Causes of Beam Loss at CEBAF

At Jefferson Lab, the Continuous Electron Beam Accelerator (CEBAF) features a unique design with two linear accelerators and two arc sections allowing for multiple turns of the electron beam, as well as four experimental end stations. This topology leads to increased beam losses, especially in the spreader and recombiner regions connecting the arcs to the linacs and in the extraction regions connecting the experimental end stations to the accelerator. These losses result in equipment activation and operational interruptions. Recent upgrades to the facility’s diagnostic systems, including the addition of xenon ion chambers, have provided higher-resolution data regarding these loss events. Building on this improved observational capability, we are developing a simulation framework using optics codes and the Geant4-based BDSIM to model beam extinction and halo formation in these regions. This work aims to correlate simulation results with experimental data to isolate the causes of beam loss and inform future machine tuning strategies. We present a summary of conclusions drawn from recent operational studies and outline a plan to model the beam loss and validate the simulations.

Matthews, C. [Old Dominion Univ., Norfolk, VA (Uni↗

MICROPHONICS TESTING OF LCLS II CRYOMODULES AT JLAB

Jefferson Lab is partnering with Fermilab to build 40 cryomodules for the LCLS II accelerator that will be installed at the Stanford Linear Accelerator (SLAC). The LCLS II cryomodule is an 8-seat CW cryomodule which operates at 1300 MHz and is based on the XFEL design. The cavities have design loaded-Q of 4×107, which means that it has a control bandwidth of 16 Hz. The JLab prototype cryomodule was instrumented with a series of 10 accelerometers, and impulse hammer response measurements were made while the cryomodule was being built and after it was installed in the JLAB cryomodule test facility. This was done so that we could better understand the shapes of the modes of the structure. These results were compared to impulse hammer testing from the outside of the cryomodule to individual cavity frequency shifts when the cryomodule was cold. Additionally, background microphonics and transfer function measurements were made on several other LCLS II cryomodules in the JLab cryomodule test facility (CMTF). The prototype cryomodule had excessive microphonics up to 100 Hz peak due to a thermo-acoustic oscillation in the cryogenic supply circuit. Design modifications were implemented and subsequently the cryomodules had microphonics on the order of 10 to 20 Hz.

Powers, Thomas↗

Preliminary Design of a LAMP DTL

A preliminary Drift Tube Linac (DTL) layout was designed to create an algorithm for developing the conceptual design of the proposed LANSCE Accelerator Modernization Project (LAMP) final section: the proton linear accelerator from 3 MeV to 100 MeV. Preceding reports describe the proposed layouts of the LEBT, the RFQ, and the MEBT subsections of the linac. Initial estimates of the needed RF power for the DTL are also presented in the report. Present report describes the initial layout of the DTL and the first longitudinal beam dynamics results of the simulations n simplified models. The follow-up reports will include the transverse focusing scheme and beam dynamics in details. Present report in the last section will only describe the planned focusing scheme, based on the existing LANCE DTL.

43 PARTICLE ACCELERATORS↗

Preliminary Design of a LAMP DTL (Update)

Present report is a continuation of the previously published report LA-UR-23-26600 from 19-Jun-2023 and incorporates the mentioned report as its part. All the additional information is contained in the part III of this report, the DTL Transverse Focusing Scheme. A preliminary Drift Tube Linac (DTL) layout was designed to create an algorithm for developing the conceptual design of the proposed LANSCE Accelerator Modernization Project (LAMP) final section: the proton linear accelerator from 3 MeV to 100 MeV. Preceding reports describe the proposed layouts of the LEBT, the RFQ, and the MEBT subsections of the linac. Initial estimates of the needed RF power for the DTL are also presented in the report. Present report describes the initial layout of the DTL and the first longitudinal beam dynamics (BD) results of the simulations in simplified models. The part III of this report includes the transverse focusing scheme and transverse BD in details.

43 PARTICLE ACCELERATORS↗

A Damping Ring for the Rapid Cycling Synchrotron

The Electron-Ion Collider (EIC) electron accelerator chain consists of a 400 MeV electron Linear Accelerator (LINAC), the Rapid Cycling Synchrotron (RCS), and the Electron Storage Ring (ESR). The LINAC injects into the RCS, the RCS ramps to a top energy of 18 GeV and the electron beam is extracted to the ESR. To minimize the momentum spread of the 400 MeV injected beam and serve as a 28 nC electron accumulator ring, a damping ring is proposed. This ring may also serve as an intermediate energy booster for the RCS. The damping ring is not within the current baseline of the EIC project.

43 PARTICLE ACCELERATORS↗

The critical role of velocity storage in production of motion sickness

We propose that motion sickness is mediated through the orientation properties of velocity storage in the vestibular system that tend to align eye velocity produced by the angular vestibulo-ocular reflex (aVOR) with gravito-inertial acceleration (GIA). (GIA is the sum of the linear accelerations acting on the head. In the absence of translational accelerations, gravity is the GIA.) We further postulate that motion sickness produced by cross-coupled vestibular stimulation can be characterized by a metric composed of the disparity between the axis of eye rotation and the GIA, the strength of the response to angular motion, and the response duration, as determined by the central vestibular time constant, that is, by the time constant of velocity storage. The nodulus and uvula of the vestibulocerebellum are likely to be the central sites where the disparity is sensed, where the vestibular time constants are habituated, and where links are made to the autonomic system to produce the symptoms and signs.

Non-NASA Center↗

Compact accelerator for medical therapy

A compact accelerator system having an integrated particle generator-linear accelerator with a compact, small-scale construction capable of producing an energetic (.about.70-250 MeV) proton beam or other nuclei and transporting the beam direction to a medical therapy patient without the need for bending magnets or other hardware often required for remote beam transport. The integrated particle generator-accelerator is actuable as a unitary body on a support structure to enable scanning of a particle beam by direction actuation of the particle generator-accelerator.

43 PARTICLE ACCELERATORS↗

Linear vs. nonlinear acceleration in plasma turbulence. II. Hall–finite-Larmor-radius magnetohydrodynamics

The local k-space ratio of linear and nonlinear accelerations associated with a variety of initial conditions undergoing steady relaxation is investigated for the Hall–finite-Larmor-radius magnetohydrodynamics (MHD) system in the presence of a mean magnetic field. Building on a related study (Paper I) where it was shown that discrepancies exist between describing the global and local characterizations of the pure MHD system with mean magnetic field, we find regions of the Fourier space that are consistently dominated by linear acceleration and other regions that are consistently dominated by nonlinear acceleration, independent of the overall system's description as linear, weakly nonlinear, or turbulent. In general, dynamics within a certain angular range of the mean magnetic field direction are predominantly linear, while dynamics adjacent the Hall scales along the field-parallel direction and dynamics adjacent the finite Larmor radius scales in the field-perpendicular direction can become strongly nonlinear. The nonlinear influences are particularly significant as the plasma beta increases from unity to higher values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Verification of Predicted Oscillations near a Spin Resonance

The E166 experiment at the Stanford Linear Accelerator Center (SLAC) has demonstrated a scheme for the production of polarized positrons which is suitable for implementation in a future Linear Collider. A multi-GeV electron beam passed through a helical undulator to generate multi-MeV, circularly polarized photons which were then converted in a thin target to produce positrons (and electrons) with longitudinal polarization above 80% at 6 MeV. The results are in agreement with GEANT4 simulations that include the dominant polarization-dependent interactions of electrons, positrons and photons in matter.

43 PARTICLE ACCELERATORS↗

Efficient continuous-wave normal conducting accelerator for industrial applications

A normal conducting, high power, high efficiency copper linear accelerator prototype is being developed for industrial applications. The system will be powered by low-cost high-efficiency magnetron RF sources and will use a gridded thermionic cathode electron gun. Leveraging the significant accelerator expertise at JLab and industry partners, these technologies will be combined to deliver high-power (>100 kW) electron beams with energies of 1 MeV or higher that are cost-effective to produce and operate. The design is modular such that energy and power can be increased by adding additional sections as required. The status of the design, prototype fabrication and plans for a beam demonstration at JLab are described.

Accelerator Physics↗

Micro-Bubble Experiments at the Van de Graaff Accelerator

In order to test and verify the experimental designs at the linear accelerator (LINAC), several micro-scale bubble ("micro-bubble") experiments were conducted with the 3-MeV Van de Graaff (VDG) electron accelerator. The experimental setups included a square quartz tube, sodium bisulfate solution with different concentrations, cooling coils, gas chromatography (GC) system, raster magnets, and two high-resolution cameras that were controlled by a LabVIEW program. Different beam currents were applied in the VDG irradiation. Bubble generation (radiolysis), thermal expansion, thermal convection, and radiation damage were observed in the experiments. Photographs, videos, and gas formation (O 2 + H 2 ) data were collected. The micro-bubble experiments at VDG indicate that the design of the full-scale bubble experiments at the LINAC is reasonable.

43 PARTICLE ACCELERATORS↗

Upgrade of the MIT Linear Electrostatic Ion Accelerator (LEIA) for nuclear diagnostics development for Omega, Z and the NIF

The MIT Linear Electrostatic Ion Accelerator (LEIA) generates DD and D{sup 3}He fusion products for the development of nuclear diagnostics for Omega, Z, and the National Ignition Facility (NIF). Significant improvements to the system in recent years are presented. Fusion reaction rates, as high as 10{sup 7} s{sup -1} and 10{sup 6} s{sup -1} for DD and D{sup 3}He, respectively, are now well regulated with a new ion source and electronic gas control system. Charged fusion products are more accurately characterized, which allows for better calibration of existing nuclear diagnostics. In addition, in situ measurements of the on-target beam profile, made with a CCD camera, are used to determine the metrology of the fusion-product source for particle-counting applications. Finally, neutron diagnostics development has been facilitated by detailed Monte Carlo N-Particle Transport (MCNP) modeling of neutrons in the accelerator target chamber, which is used to correct for scattering within the system. These recent improvements have resulted in a versatile platform, which continues to support the existing nuclear diagnostics while simultaneously facilitating the development of new diagnostics in aid of the National Ignition Campaign at the National Ignition Facility.

43 PARTICLE ACCELERATORS↗

LCLS-II high power RF system overview and progress

A second X-ray free electron laser facility, LCLS-II, will be constructed at SLAC. LCLS-II is based on a 1.3 GHz, 4 GeV, continuous-wave (CW) superconducting linear accelerator, to be installed in the first kilometer of the SLAC tunnel. Multiple types of high power RF (HPRF) sources will be used to power different systems on LCLS-II. The main 1.3 GHz linac will be powered by 280 1.3 GHz, 3.8 kW solid state amplifier (SSA) sources. The normal conducting buncher in the injector will use four more SSAs identical to the linac SSAs but run at 2 kW. Two 185.7 MHz, 60 kW sources will power the photocathode dual-feed RF gun. A third harmonic linac section, included for linearizing the bunch energy spread before the first bunch compressor, will require sixteen 3.9 GHz sources at about 1 kW CW. A description and an update on all the HPRF sources of LCLS-II and their implementation is the subject of this paper.

43 PARTICLE ACCELERATORS↗

Acceleration in the linear non-scaling fixed-field alternating-gradient accelerator EMMA

In a fixed-field alternating-gradient (FFAG) accelerator, eliminating pulsed magnet operation permits rapid acceleration to synchrotron energies, but with a much higher beam-pulse repetition rate. Conceived in the 1950s, FFAGs are enjoying renewed interest, fuelled by the need to rapidly accelerate unstable muons for future high-energy physics colliders. Until now a 'scaling' principle has been applied to avoid beam blow-up and loss. Removing this restriction produces a new breed of FFAG, a non-scaling variant, allowing powerful advances in machine characteristics. We report on the first non-scaling FFAG, in which orbits are compacted to within 10?mm in radius over an electron momentum range of 12-18 MeV/c. In this strictly linear-gradient FFAG, unstable beam regions are crossed, but acceleration via a novel serpentine channel is so rapid that no significant beam disruption is observed. This result has significant implications for future particle accelerators, particularly muon and high-intensity proton accelerators.

43 PARTICLE ACCELERATORS↗

Vestibulo-ocular reflex of the squirrel monkey during eccentric rotation with centripetal acceleration along the naso-occipital axis

The vestibulo-ocular reflexes (VOR) are determined not only by angular acceleration, but also by the presence of gravity and linear acceleration. This phenomenon was studied by measuring three-dimensional nystagmic eye movements, with implanted search coils, in four male squirrel monkeys. Monkeys were rotated in the dark at 200 degrees/s, centrally or 79 cm off-axis, with the axis of rotation always aligned with gravity and the spinal axis of the upright monkeys. The monkey's position relative to the centripetal acceleration (facing center or back to center) had a dramatic influence on the VOR. These studies show that a torsional response was always elicited that acted to shift the axis of eye rotation toward alignment with gravito-inertial force. On the other hand, a slow phase downward vertical response usually existed, which shifted the axis of eye rotation away from the gravito-inertial force. These findings were consistent across all monkeys. In another set of tests, the same monkeys were rapidly tilted about their interaural (pitch) axis. Tilt orientations of 45 degrees and 90 degrees were maintained for 1 min. Other than a compensatory angular VOR during the rotation, no consistent eye velocity response was ever observed during or following the tilt. The absence of any response following tilt proves that the observed torsional and vertical responses were not a positional nystagmus. Model simulations qualitatively predict all components of these eccentric rotation and tilt responses. These simulations support the conclusion that the VOR during eccentric rotation may consist of two components: a linear VOR and a rotational VOR. The model predicts a slow phase downward, vertical, linear VOR during eccentric rotation even though there was never a change in the force aligned with monkey's spinal (Z) axis. The model also predicts the torsional components of the response that shift the rotation axis of the angular VOR toward alignment with gravito-inertial force.

NASA Center JSC↗

Characterisation of electron beams from laser-driven particle accelerators

The development, understanding and application of laser-driven particle accelerators require accurate measurements of the beam properties, in particular emittance, energy spread and bunch length. Here we report measurements and simulations showing that laser wakefield accelerators can produce beams of quality comparable to conventional linear accelerators.

43 PARTICLE ACCELERATORS↗