Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material point method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Method for Measuring Collimator-Pointing Sensitivity to Temperature Changes

For a variety of applications, it is important to measure the sensitivity of the pointing of a beam emerging from a collimator, as a function of temperature changes. A straightforward method for carrying out this measurement is based on using interferometry for monitoring the changes in beam pointing, which presents its own problems. The added temperature dependence and complexity issues relating to using an interferometer are addressed by not using an interferometer in the first place. Instead, the collimator is made part of an arrangement that uses a minimum number of low-cost, off-the-shelf materials and by using a quad diode to measure changes in beam pointing. In order to minimize the influence of the test arrangement on the outcome of the measurement, several steps are taken. The collimator assembly is placed on top of a vertical, 1-m-long, fused silica tube. The quad diode is bonded to a fused silica bar, which, in turn, is bonded to the lower end of the fused silica tube. The lower end of the tube rests on a self-aligning support piece, while the upper end of the tube is kept against two rounded setscrew tips, using a soft rubber string. This ensures that very little stress is applied to the tube as the support structure changes dimensions due to thermal expansion. Light is delivered to the collimator through a bare fiber in order to minimize variable bending torque caused by a randomly relaxing, rigid fiber jacket. In order to separate the effect of temperature on the collimator assembly from the effect temperature has on the rest of the setup, multiple measurements are taken with the collimator assembly rotated from measurement to measurement. Laboratory testing, with 1-m spacing between the collimator and the quad diode, has shown that the sensitivity of the arrangement is better than 100 nm rms, over time spans of at least one hour, if the beam path is protected from atmospheric turbulence by a tube. The equivalent sensitivity to detecting changes in pointing angle is 100 nanoradians.

Abramovici, Alex↗

Method of reducing temperature in high-speed photography

A continuing problem in high-speed motion picture photography is adequate lighting and the associated temperature rise. Large temperature rises can damage subject matter and make recording of the desired images impossible. The problem is more severe in macrophotography because of bellows extension and the necessary increase in light. This report covers one approach to reducing the initial temperature rise: the use of filters and heat-absorbing materials. The accompanying figures provide the starting point for selecting distance as a function of light intensity and determining the associated temperature rise. Using these figures will allow the photographer greater freedom in meeting different photographic situations.

Walker, E. D.↗

Localizing Holes as Polarons and Predicting Band Gaps, Defect Levels, and Delithiation Energies of Solid-State Materials with a Local Exchange-Correlation Functional

Here, we assess the performance of seven exchange–correlation functionals (some with and some without a Hubbard U correction) for their ability (i) to predict band gaps of silicon, diamond, and Li-ion battery cathode materials, (ii) to localize hole polarons and predict delithiation energies in Li-ion battery cathode materials, and (iii) to predict transition levels of charge carriers of doped silicon and diamond. Both local and hybrid exchange–correlation functionals were tested. The local functionals tend to underestimate band gaps and delocalize polarons. The hybrid functionals very often give a good description of both properties, but they may not be practical for calculations involving large unit cells, large ensembles, or dynamics, and therefore a local functional with a Hubbard U correction is often used (giving the method called DFT+U), where the value of a parameter U is adjusted according to the system and the property being investigated. Keeping in mind the importance of computational cost and the undesirability of having to adjust an empirical parameter for each system or property of interest, we recently developed a local functional, namely HLE17, to try to accurately predict band gaps and excitation energies, and we validated it using mostly main-group solids and molecules. Here we test the performance of HLE17 for its ability to predict band gaps and localize polarons in other solid-state materials, and we compare its performance to that of popular local functionals (PBE, PBEsol, and TPSS), a range-separated hybrid functional with screened exchange (HSE06), and DFT+U. We find that HLE17 predicts more accurate band gaps than other local functionals and can localize holes as polarons, which other local functionals usually fail to do, and for a number of cases it is comparable in performance quality to Hubbard-corrected functionals without the need for system-specific parametrization and to hybrid functionals without the high cost. Because HLE17 does not predict accurate lattice constants, we use the single-point method of quantum chemistry, where the geometry is optimized with one functional and the band gap is calculated with HLE17, or we perform calculations with the lattice constants obtained by TPSS and both the fractional intracell coordinates and the electronic structure obtained by HLE17 (a new method denoted HLE17\\TPSS). In particular, we performed calculations by HLE17//TPSS, HLE17//HSE06, HLE17//DFT+U, and HLE17\\TPSS, and these methods usually agree well with each other and give values similar to experiment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design Report on the MiniFuel Instrumented Test Apparatus for Understanding Radiation Effects

Most nuclear fuels irradiations at Oak Ridge National Laboratory (ORNL) over the past decade have been conducted using MiniFuel—a static capsule design employing subscale fuel specimens to collect separate-effects irradiated fuel performance data. Irradiation conditions for MiniFuel experiments are predicted pre-test using reactor physics, and thermal models are verified post-irradiation via SiC dilatometry and various spectrometry methods. Relevant fuel performance parameters are also observed post-irradiation in a hot cell, thereby providing a single data point for each parameter representing the cumulative effects of the irradiation conditions. Substantially more data can be harvested from a single test and within a shorter duration by instrumenting irradiation vehicles and measuring desired quantities in situ. This report presents the design and analysis of the MiniFuel INstrumented Irradiation Test Apparatus for Understanding Radiation Effects (MINITAURE)—an instrumented test rig based on the separate-effects MiniFuel concept that aims to capture fission gas release (FGR) and thermal conductivity degradation of fuel specimens during irradiation in the High Flux Isotope Reactor (HFIR). MINITAURE will be integrated with the Materials Irradiation Facility (MIF) located in the HFIR building outside the reactor containment. The MIF will act as the instrumentation and control center for the experiment, enabling real-time feedback from in situ sensors and control of irradiation temperatures via a gas delivery system. Two unique capsule designs were developed to capture each phenomenon: the thermal conductivity capsule, which uses a thermopile method to estimate fuel specimen thermal conductivity, and the fission gas release capsule, which will have continuous flowing gas communication to high-purity germanium detectors that are housed in the MIF for monitoring FGR. This report details the reactor physics and heat transfer modeling activities that were used to inform the experiment design and predict capsule performance. It also describes out-of-pile activities conducted to stand up this new capability and verify the measurement techniques. Modeling efforts to date have demonstrated the feasibility of the in situ measurement techniques and supported the development of the MINITAURE assembly configuration. Out-of-pile testing of the thermal conductivity measurement shows promise in capturing relative changes in thermal conductivity. However, significant errors exist in the measured absolute value, posing a need for further refinement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Magnetic Resonance Imaging-Based Radiation-Absorbed Dose Estimation of {sup 166}Ho Microspheres in Liver Radioembolization

Purpose: To investigate the potential of magnetic resonance imaging (MRI) for accurate assessment of the three-dimensional {sup 166}Ho activity distribution to estimate radiation-absorbed dose distributions in {sup 166}Ho-loaded poly (L-lactic acid) microsphere ({sup 166}Ho-PLLA-MS) liver radioembolization. Methods and Materials: MRI, computed tomography (CT), and single photon emission CT (SPECT) experiments were conducted on an anthropomorphic gel phantom with tumor-simulating gel samples and on an excised human tumor-bearing liver, both containing known amounts of {sup 166}Ho-PLLA-MS. Three-dimensional radiation-absorbed dose distributions were estimated at the voxel level by convolving the {sup 166}Ho activity distribution, derived from quantitative MRI data, with a {sup 166}Ho dose point-kernel generated by MCNP (Monte Carlo N-Particle transport code) and from Medical Internal Radiation Dose Pamphlet 17. MRI-based radiation-absorbed dose distributions were qualitatively compared with CT and autoradiography images and quantitatively compared with SPECT-based dose distributions. Both MRI- and SPECT-based activity estimations were validated against dose calibrator measurements. Results: Evaluation on an anthropomorphic phantom showed that MRI enables accurate assessment of local {sup 166}Ho-PLLA-MS mass and activity distributions, as supported by a regression coefficient of 1.05 and a correlation coefficient of 0.99, relating local MRI-based mass and activity calculations to reference values obtained with a dose calibrator. Estimated MRI-based radiation-absorbed dose distributions of {sup 166}Ho-PLLA-MS in an ex vivo human liver visually showed high correspondence to SPECT-based radiation-absorbed dose distributions. Quantitative analysis revealed that the differences in local and total amounts of {sup 166}Ho-PLLA-MS estimated by MRI, SPECT, and the dose calibrator were within 10%. Excellent agreement was observed between MRI- and SPECT-based dose-volume histograms. Conclusions: Quantitative MRI was demonstrated to provide accurate three-dimensional {sup 166}Ho-PLLA-MS activity distributions, enabling localized intrahepatic radiation-absorbed dose estimation by convolution with a {sup 166}Ho dose point-kernel for liver radioembolization treatment optimization and evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of the Chlorination Products of Zirconium Alloys used for Nuclear Fuel Cladding

The United States produces over 2000 metric tons of used nuclear fuel material per year, of which 25% is irradiated fuel cladding, and it is expected to increase for the next 50 years. Previous simulation studies have shown that in the irradiated cladding, the major activation products found are {sup 125}Sb, {sup 60}Co, and {sup 99m}Nb, and the major fission product found is {sup 137}Cs. These radioisotopes make it impossible to treat the cladding as low level waste. A chlorination process has been proposed for zirconium reprocessing as it has been proven more efficient than previous mechanical processes, redox processes, and other chemical methods (e.g. iodination). In the chlorination process, zirconium alloy cladding reacts with Cl{sub 2} at 350- 380 deg. C to produce mainly ZrCl{sub 4}. The zirconium tetrachloride has a relatively low sublimation point (331 deg. C) that allows its separation from other products, and so it can be treated as low level waste for disposal or recycling. However, previous work has observed element impurities (iron, tin, chromium, cesium, antimony, and niobium) in the recovered ZrCl{sub 4}, meaning that additional steps are necessary in a chlorination process previous to the reduction of ZrCl, to metallic Zr. The emphasis of this research summary is on the progress that has been made to isolate and characterize the impurities produced after chlorination of three previously characterized non-irradiated zirconium alloys (Zircaloy-2, Zircaloy-4, and a commercial Zr-Nb alloy) widely used as cladding materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determining Physical Parameters of Shielded Uranium using Gamma Spectroscopy and the Differential Evolution Adaptive Metropolis (DREAM) Method

Inverse radiation transport is a well-established method for determining unknown parameters within a system that exhibits particle leakage. Two significant challenges of solving inverse transport problems are (1) to determine multiple unknowns without false convergence on local minima and (2) to be able to quantify uncertainty. It was recently demonstrated that the Differential Evolution Adaptive Metropolis (DREAM) method effectively meets both of these challenges. In Bledsoe's 2014 article, the DREAM method was only applied to numerical test cases in which measured data were simulated using MCNP. This paper provides results of research conducted at Oak Ridge National Laboratory (ORNL) in which DREAM was applied to two-dimensional inverse transport problems using real-world measurements. The DREAM method uses a Markov chain Monte Carlo (MCMC) method to obtain a posterior distribution of unknown parameters. In this application, the posterior distribution is determined by using a uniform prior distribution and a likelihood function. The goal of the inverse problem is to find the regions in which the likelihood function is at or near its maximum. In the traditional MCMC approach, a single Markov chain is employed. In practice, MCMC approaches have a high acceptance rate to solutions that are near the current point of sampling, but they exhibit slow convergence to solutions far from the sampling point. The DREAM algorithm was designed to alleviate this issue by initiating multiple Markov chains and using the differential evolution algorithm to generate trial points for each chain. Solving for the mass of radioactive material within a voluminous source is a challenging problem for gamma-ray spectroscopy. Inverse gamma-ray transport can supply a range of possible material compositions, but reducing the differences between predicted and actual measurements can lead to false results. DREAM is a rapid technique for determining the most likely solution for several unknown parameters in an inverse transport problem. This work applies DREAM to a series of gamma spectroscopy experiments performed at ORNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and application of processing and process control for nano-composite materials for lithium ion batteries (CRADA Final Report)

Oak Ridge National Laboratory and A123 Systems, Inc. collaborated on this project to develop a better understanding, quality control procedures, and safety testing for A123 System’s nanocomposite separator (NCS) technology which is a cell based patented technology and separator. NCS demonstrated excellent performance. x3450 prismatic cells were shown to survive >8000 cycles (1C/2C rate) at room temperature with greater than 80% capacity retention with only NCS present as an alternative to conventional polyolefin. However, for a successful commercialization, the coating conditions required to provide consistent and reliable product had not been optimized and QC techniques for being able to remove defective material before incorporation into a cell had not been developed. The work outlined in this report addresses these latter two points. First, experiments were conducted to understand temperature profiles during the different drying stages of the NCS coating when applied to both anode and cathode. One of the more interesting discoveries of this study was the observation of the large temperature decrease experienced by the wet coating between the end of the infrared (IR) drying stage and the beginning of the exposure to the convection drying oven. This is not a desirable situation as the temperature gradient could have a deleterious effect on coating quality. Based on this and other experimental data a radiative transfer model was developed for IR heating that also included a mass transfer module for drying. This will prove invaluable for battery coating optimization especially where IR drying is being employed. A stress model was also developed that predicts that under certain drying conditions tensile stresses are formed in the coating which could lead to cracking that is sometimes observed after drying is complete. Prediction of under what conditions these stresses form is vital to improving coating quality. In addition to understanding the drying process other parameters such as slurry quality and equipment optimization were examined. Removal of particles and gels by filtering, control of viscosity by %solids and mixing adjustments, removal of trapped gas in the slurry and modification of coater speed and slot die gap were all found to be important for producing uniform and flaw-free coatings. Second, an in-line Hi-Pot testing method has been developed specifically for NCS that will enable detection of coating flaws that could lead to soft or hard electrical shorts within the cell. In this way flawed material can be rejected before incorporation into the cell thus greatly reducing the amount of scrap that is generated. Improved battery safety is an extremely important benefit of NCS. Evaluation of battery safety is usually accomplished by conducting a variety of tests including nail penetration, hot box, over charge, etc. For these tests entire batteries must be built but the resultant temperature and voltage responses reveal little about the breakdown mechanism. In this report is described a pinch test which is used to evaluate NCS quality at various stages including coated anode and cathode as well as assembled cell. Coupled with post-microscopic examination of the damaged ‘pinch point’ test data can assist in the coating optimization from an improved end-use standpoint. As a result of this work two invention disclosures, one for optimizing drying methodology and the other for an in-line system for flaw detection, have been filed. In addition, 2 papers are being written for submission to peer-reviewed journals.

25 ENERGY STORAGE↗

Clopidogrel Responsiveness in Patients Undergoing Peripheral Angioplasty

Purpose: To investigate the incidence and clinical significance of platelet responsiveness in patients receiving clopidogrel after peripheral angioplasty procedures. Materials and Methods: This prospective study included patients receiving antiplatelet therapy with clopidogrel 75 mg after infrainguinal angioplasty or stenting and who presented to our department during routine follow-up. Clopidogrel responsiveness was tested using the VerifyNow P2Y12 Assay. Patients with residual platelet reactivity units (PRU) {>=} 235 were considered as nonresponders (NR group NR), whereas patients with PRU < 235 were considered as normal (responders [group R]). Primary end points were incidence of resistance to clopidogrel and target limb reintervention (TLR)-free survival, whereas secondary end points included limb salvage rates and the identification of any independent predictors influencing clinical outcomes. Results: In total, 113 consecutive patients (mean age 69 {+-} 8 years) with 139 limbs were enrolled. After clopidogrel responsiveness analysis, 61 patients (53.9 %) with 73 limbs (52.5 %) were assigned to group R and 52 patients (46.1 %) with 66 limbs (47.5 %) to group NR. Mean follow-up interval was 27.7 {+-} 22.9 months (range 3-95). Diabetes mellitus, critical limb ischemia, and renal disease were associated with clopidogrel resistance (Fisher's exact test; p < 0.05). According to Kaplan-Meier analysis, TLR-free survival was significantly superior in group R compared with group NR (20.7 vs. 1.9 %, respectively, at 7-year follow-up; p = 0.001), whereas resistance to clopidogrel was identified as the only independent predictor of decreased TLR-free survival (hazard rate 0.536, 95 % confidence interval 0.31-0.90; p = 0.01). Cumulative TLR rate was significantly increased in group NR compared with group R (71.2 % [52 of 73] vs. 31.8 % [21 of 66], respectively; p < 0.001). Limb salvage was similar in both groups. Conclusion: Clopidogrel resistance was related with significantly more repeat interventions after peripheral angioplasty procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A parallel discrete dislocation dynamics/kinetic Monte Carlo method to study non-conservative plastic processes

Non-conservative processes play a fundamental role in plasticity and are behind important macroscopic phenomena such as creep, dynamic strain aging, loop raft formation, etc. In the most general case, vacancy-induced dislocation climb is the operating unit mechanism. While dislocation/vacancy interactions have been modeled in the literature using a variety of methods, the approaches developed rely on continuum descriptions of both the vacancy population and its fluxes. However, there are numerous situations in physics where point defect populations display heterogeneous concentrations and/or non-smooth kinetics. Here, a kinetic Monte Carlo (kMC) approach for modeling vacancy transport in response to arbitrary stress fields is used. Vacancies are treated as point particles and are coupled to the dislocation substructure representing a deformed material via an advection term defined by the local stress gradients. The stress fields and the dislocation substructure are evolved using a discrete dislocation dynamics (DDD) module. To extend the coupled model to the treatment of large systems, we have implemented it in the massively-parallel DDD code ParaDiS. To avoid numerical incompatibilities associated with merging deterministic (DDD) and stochastic (kMC) integration algorithms, we cast the entire elasto-plastic-diffusive problem within a single stochastic framework, taking advantage of a parallel kMC algorithm to evolve the system as a single event-driven process. The large-scale implementation enables the study of the evolution of a variety of dislocation-defect scenarios governed by non-conservative transport kinetics. After carrying out an exhaustive numerical and computational analysis of our parallel algorithm, we show results that emphasize situations where inhomogeneous vacancy dynamics are of relevance, and compare discrete kinetics to continuum solutions for several cases.

36 MATERIALS SCIENCE↗

Volumetric-Modulated Arc Therapy: Effective and Efficient End-to-End Patient-Specific Quality Assurance

Purpose: To explore an effective and efficient end-to-end patient-specific quality-assurance (QA) protocol for volumetric modulated arc radiotherapy (VMAT) and to evaluate the suitability of a stationary radiotherapy QA device (two-dimensional [2D] ion chamber array) for VMAT QA. Methods and Materials: Three methods were used to analyze 39 VMAT treatment plans for brain, spine, and prostate: ion chamber (one-dimensional absolute, n = 39), film (2D relative, coronal/sagittal, n = 8), and 2D ion chamber array (ICA, 2D absolute, coronal/sagittal, n = 39) measurements. All measurements were compared with the treatment planning system dose calculation either via gamma analysis (3%, 3- to 4-mm distance-to-agreement criteria) or absolute point dose comparison. The film and ion chamber results were similarly compared with the ICA measurements. Results: Absolute point dose measurements agreed well with treatment planning system computed doses (ion chamber: median deviation, 1.2%, range, -0.6% to 3.3%; ICA: median deviation, 0.6%, range, -1.8% to 2.9%). The relative 2D dose measurements also showed good agreement with computed doses (>93% of pixels in all films passing gamma, >90% of pixels in all ICA measurements passing gamma). The ICA relative dose results were highly similar to those of film (>90% of pixels passing gamma). The coronal and sagittal ICA measurements were statistically indistinguishable by the paired t test with a hypothesized mean difference of 0.1%. The ion chamber and ICA absolute dose measurements showed a similar trend but had disparities of 2-3% in 18% of plans. Conclusions: After validating the new VMAT implementation with ion chamber, film, and ICA, we were able to maintain an effective yet efficient patient-specific VMAT QA protocol by reducing from five (ion chamber, film, and ICA) to two measurements (ion chamber and single ICA) per plan. The ICA (Matrixx Registered-Sign , IBA Dosimetry) was validated for VMAT QA, but ion chamber measurements are recommended for absolute dose comparison until future developments correct the ICA angular dependence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Stereotactic Body Radiation Therapy an Attractive Option for Unresectable Liver Metastases? A Preliminary Report From a Phase 2 Trial

Purpose: To evaluate the feasibility of high-dose stereotactic body radiation therapy (SBRT) in the treatment of unresectable liver metastases. Methods and Materials: Patients with 1 to 3 liver metastases, with maximum individual tumor diameters less than 6 cm and a Karnofsky Performance Status of at least 70, were enrolled and treated by SBRT on a phase 2 clinical trial. Dose prescription was 75 Gy on 3 consecutive days. SBRT was delivered using the volumetric modulated arc therapy by RapidArc (Varian, Palo Alto, CA) technique. The primary end-point was in-field local control. Secondary end-points were toxicity and survival. Results: Between February 2010 and September 2011, a total of 61 patients with 76 lesions were treated. Among the patients, 21 (34.3%) had stable extrahepatic disease at study entry. The most frequent primary sites were colorectal (45.9%) and breast (18%). Of the patients, 78.7% had 1 lesion, 18.0% had 2 lesions, and 3.3% had 3 lesions. After a median of 12 months (range, 2-26 months), the in-field local response rate was 94%. The median overall survival rate was 19 months, and actuarial survival at 12 months was 83.5%. None of the patients experienced grade 3 or higher acute toxicity. No radiation-induced liver disease was detected. One patient experienced G3 late toxicity at 6 months, resulting from chest wall pain. Conclusions: SBRT for unresectable liver metastases can be considered an effective, safe, and noninvasive therapeutic option, with excellent rates of local control and a low treatment-related toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a Quality and Safety Competency Curriculum for Radiation Oncology Residency: An International Delphi Study

Purpose: To develop an entry-to-practice quality and safety competency profile for radiation oncology residency. Methods and Materials: A comprehensive list of potential quality and safety competency items was generated from public and professional resources and interprofessional focus groups. Redundant or out-of-scope items were eliminated through investigator consensus. Remaining items were subjected to an international 2-round modified Delphi process involving experts in radiation oncology, radiation therapy, and medical physics. During Round 1, each item was scored independently on a 9-point Likert scale indicating appropriateness for inclusion in the competency profile. Items indistinctly ranked for inclusion or exclusion were re-evaluated through web conference discussion and reranked in Round 2. Results: An initial 1211 items were compiled from 32 international sources and distilled to 105 unique potential quality and safety competency items. Fifteen of the 50 invited experts participated in round 1: 10 radiation oncologists, 4 radiation therapists, and 1 medical physicist from 13 centers in 5 countries. Round 1 rankings resulted in 80 items included, 1 item excluded, and 24 items indeterminate. Two areas emerged more prominently within the latter group: change management and human factors. Web conference with 5 participants resulted in 9 of these 24 items edited for content or clarity. In Round 2, 12 participants rescored all indeterminate items resulting in 10 items ranked for inclusion. The final 90 enabling competency items were organized into thematic groups consisting of 18 key competencies under headings adapted from Deming's System of Profound Knowledge. Conclusions: This quality and safety competency profile may inform minimum training standards for radiation oncology residency programs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spatial and Temporal Quantification of Spontaneous Imbibition

Spontaneous imbibition–the process of a wetting fluid displacing a non-wetting fluid purely by capillary forces–is a ubiquitous phenomenon in porous and fibrous materials. Here we present a new experimental method for quantification of spontaneous imbibition in geologic materials. This method makes it possible to perform spontaneous imbibition under elevated pressure conditions relevant to environmental and energy resource applications. In this work, computed tomography imaging reveals a new time-independent scaling relationship that describes local imbibition rates as a function of water saturation. Imbibition capillary pressure curves are calculated with this wetting-phase pressure and flowrate characterization, with no assumptions about the functional form, end point behavior, or scaling factors. Calculated end-point capillary pressure is nonzero, in agreement with recent pore-scale measurements of capillary pressure of trapped nonwetting phase. This work provides a new approach and insights into trapping and remobilization of non-wetting fluids in CO 2 storage reservoirs and contaminated groundwater aquifers.

58 GEOSCIENCES↗

Atomistic learning in the electronically grand-canonical ensemble

Abstract A strategy is presented for the machine-learning emulation of electronic structure calculations carried out in the electronically grand-canonical ensemble. The approach relies upon a dual-learning scheme, where both the system charge and the system energy are predicted for each image. The scheme is shown to be capable of emulating basic electrochemical reactions at a range of potentials, and coupling it with a bootstrap-ensemble approach gives reasonable estimates of the prediction uncertainty. The method is also demonstrated to accelerate saddle-point searches, and to extrapolate to systems with one to five water layers. We anticipate that this method will allow for larger length- and time-scale simulations necessary for electrochemical simulations.

36 MATERIALS SCIENCE↗

Annealing behavior of the EB-centers and M-center in low-energy electron irradiated n-type 4H-SiC

After low-energy electron irradiation of epitaxial n-type 4H-SiC with a dose of 5x10{sup 16} cm{sup -2}, the bistable M-center, previously reported in high-energy proton implanted 4H-SiC, is detected in the deep level transient spectroscopy (DLTS) spectrum. The annealing behavior of the M-center is confirmed, and an enhanced recombination process is suggested. The annihilation process is coincidental with the evolvement of the bistable EB-centers in the low temperature range of the DLTS spectrum. The annealing energy of the M-center is similar to the generation energy of the EB-centers, thus partial transformation of the M-center to the EB-centers is suggested. The EB-centers completely disappeared after annealing temperatures higher than 700 deg. C without the formation of new defects in the observed DLTS scanning range. The threshold energy for moving Si atom in SiC is higher than the applied irradiation energy, and the annihilation temperatures are relatively low, therefore the M-center, EH1 and EH3, as well as the EB-centers are attributed to defects related to the C atom in SiC, most probably to carbon interstitials and their complexes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of the V{sub As}V{sub Ga} complex defect doping on properties of the semi-insulating GaAs

The different position V{sub As}V{sub Ga} cluster defect doping in semi-insulating (SI) GaAs has been studied by first-principles calculation based on hybrid density functional theory. Our calculated results show that EL6 level is formed due to the V{sub As}V{sub Ga} complex defect, which is very close to the experimental result. It provides the explanation of the absorption of laser with the wavelength beyond in semi-insulating GaAs. The formation energy of V{sub As}V{sub Ga} complex defect is found to decrease from surface to interior gradually. The conduction band minima and valence band maxima of GaAs (001) surface with the V{sub As}V{sub Ga} complex defect are all located at Γ point, and some defect levels are produced in the forbidden band. In contrast, the conduction band minima and valence band maxima of GaAs with the interior V{sub As}V{sub Ga} complex defect are not located at the same k-point, so it might involve the change of momentum in the electron transition process. The research will help strengthen the understanding of photoelectronic properties and effectively guide the preparation of the SI-GaAs materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mechanism of compensation of the donor impurity in the near-surface layer of gap during heat treatment in phosphorus vapors

The secondary ion mass spectrometry and capacitance-voltage measurements have been used to study the mechanism of formation of the near-surface layer with a low concentration of uncompensated donors in n-GaP grown by vapor-phase epitaxy and subjected to heat treatment at different pressures of phosphorus vapors. The dependence of the thickness of the mentioned layer on the pressure of phosphorus vapors has a minimum at a pressure of (1.5 {+-} 0.5) x 10{sup 3} Pa. It is shown that at vapor pressures above the mentioned value, the interstitial P, which forms a deep electron trap, is a suitable candidate for the role of compensating acceptor. At low pressures, the probable compensating center is the P vacancy giving rise to a deep level with the energy Ec-(0.21 {+-} 0.01) eV. At 700 deg. C, the effective diffusivity of interstitial P is {approx}(3 {+-} 1) s- 10{sup -15} cm{sup 2}/s, while that of the P vacancy is {approx}(3 {+-} 1) x 10{sup -14} cm{sup 2}/s.

36 MATERIALS SCIENCE↗