Relationship of deep defects to oxygen and hydrogen content in nanocrystalline silicon photovoltaic materials

We report measurements of the structural and compositional properties of a range of hydrogenated nanocrystalline films. We employed Raman spectroscopy for crystallinity and time-of-flight secondary ion mass spectroscopy (TOF-SIMS) for impurity characterizations. The crystalline volume fractions and impurity levels are correlated with the deep state densities determined by drive level capacitance profiling. Those defects were found to have a thermal emission energy of 0.65{+-}.05 eV. We found that the overall crystallinity correlated reasonably well with the density of such defect states and also found a strong correlation between the defect density and the levels of oxygen impurities. Possible origins of these defects are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Driving vertical phase separation in a bulk-heterojunction by inserting a poly(3-hexylthiophene) layer for highly efficient organic solar cells

A desirable vertical phase separation of a bulk-heterojunction was achieved by inserting a P3HT layer between the blend layer and the poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) layer. According to the high (PEDOT:PSS) and low (P3HT) surface energies of substrate, it might be possible to modulate the vertical phase separation in the bulk-heterojunction. The result of vertical phase separation was determined using time-of-flight secondary-ion mass spectroscopy analysis. A controlled thickness of 50 nm for the inserted P3HT layer prevented undesirable light absorption and the power conversion efficiency of this condition was increased by 44% compared to that of a reference device.

36 MATERIALS SCIENCE↗

Surface Oxidation Effects During Low Energy BF{sub 2}{sup +} Ion Implantation

We present results on silicon wafer surface oxidation observed during low energy high dose BF{sub 2}{sup +} implantation. Experiments were performed on single-crystal and pre-amorphized silicon wafers that help elucidate the surface structure impact on boron distribution profiles and dose retention. Implanters with different architectures were compared including both single wafer and batch systems. It was found that the oxidation rate depends on implanter type and design, and that the surface oxide thickness is a linear function of implantation dose and time. Surface oxidation is significantly higher for batch systems compared to single wafer tools. This is due primarily to the significantly lower beam duty cycle on the batch implanter. The oxide thicknesses estimated from SIMS oxygen profiles are in agreement with ellipsometry measurements after spike annealing, and show a similar difference between single wafer and batch implanters. SIMS boron distribution profiles after implantation were compared and used to calculate retained dose. In the medium dose range ({<=}3x10{sup 14} at/cm{sup 2}) the profiles from different implanters are well matched and the dose retention is close to 100%. For the higher dose range ({>=}3x10{sup 15} at/cm{sup 2}) retention for the batch implanter is significantly less than the single wafer tool and depends on the wafer surface structure. A higher oxidation rate results in lower dopant activation and higher Rs value after spike annealing. For high implantation doses the single wafer system allows much higher dose retention and better boron activation after annealing.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Biomolecular Emission by Swift Heavy Ion Bombardment

Secondary Ion Mass spectrometry (SIMS) has been generally used in the field of material sciences. In recent years, it has also been applied for molecular imaging of biological samples. Nevertheless, molecular ions derived from the large molecules (more than 1 kDa) were detected with very low sensitivity. Plasma desorption mass spectrometry (PDMS) is known as mass spectrometry for large organic molecule. In PDMS, fission fragments bombard samples and the impact induces molecular ionization by electronic excitation. Large organic molecules are detected by using swift heavy ions in SIMS. In this work, 6 MeV Cu{sup 4+} we irradiated angiotensin II, a class of peptides. The intact molecular ions generated by swift heavy ion irradiation were analyzed by time-of-flight (TOF) measurement. The yields are compared with some other probe ions, bismuth or flurane. Swift heavy ion bombardment ionized large organic molecules more effectively than other probes. Therefore, high energy ion can be applied in high resolution molecular imaging.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluation of surface damage on organic materials irradiated with Ar cluster ion beam

The sputtering yields of organic materials under large cluster ion bombardment are much higher than those under conventional monomer ion bombardment. The sputtering rate of arginine remains constant with fluence for an Ar cluster ion beam, but decreases with fluence for Ar monomer. Additionally, because Ar cluster etching induces little damage, Ar cluster ion can be used to achieve molecular depth profiling of organic materials. In this study, we evaluated the damage to poly methyl methacrylate (PMMA) and arginine samples irradiated with Ar atomic and Ar cluster ion beams. Arginine samples were analyzed by secondary ion mass spectrometry (SIMS) and PMMA samples were analyzed by X-ray photoelectron spectroscopy (XPS). The chemical structure of organic materials remained unchanged after Ar cluster irradiation, but was seriously damaged. These results indicated that bombardment with Ar cluster ions induced less surface damage than bombardment with Ar atomic ion. The damage layer thickness with 5 keV Ar cluster ion bombardment was less than 1 nm.

36 MATERIALS SCIENCE↗

Ribbon and Spot Beam Process Performance of the Dual Mode iPulsar High Current Ion Implanter

Low energy implant process data are presented from a dual mode high current ion implanter. The iPulsar is a flexible single wafer implanter capable of running both ribbon beams with one-dimensional mechanical scan of the wafer and spot beams with two-dimensional wafer scan. The main components of the implanter are described and their operation explained. Boron concentration profiles in Ge pre-amorphized substrates, measured by secondary ion mass spectroscopy (SIMS) are presented before and after anneal with drift and decelerated beams. In addition, spot and ribbon beam as-implanted phosphorus and carbon profiles are presented and the characteristics of each mode of operation are discussed.

36 MATERIALS SCIENCE↗

True Zero Degree Incident Implants on VIISta3000

The deliberate use of channeling to control depth profiles has come of age in the application to CMOS imaging sensor device manufacturing. In order to enable the true zero implant application on VIISta3000, we have optimized beam incidence angle control, using beam optics models and experimental measurements. The experiment measurement and the beam optics analysis results agree, showing a variation of less than 0.03 deg. (1{sigma}) across the wafer and from wafer to wafer. Achieving this accuracy in a manufacturing environment requires careful calibration and tight control of the collimator magnet and the mechanical scan system. In this paper we discuss the root cause of beam incidence angle variation on VIISta3000 and explain the calibration and optimization used to insure the consistent minimized beam incidence angle. We show experimental data, including ThermaWave and SIMS profiles.

43 PARTICLE ACCELERATORS↗

Synthesis of Endohedral Fullerene Using ECR Ion Source

We are developing an ECRIS apparatus which is designed for the production of endohedral fullerenes. Our promising approaches to produce the endohedral fullerenes using the ECRIS are the ion-ion collision reaction of fullerenes and the other atom in their mixture plasma and simple ion implantation of atom into fullerene layer. In this study, we tried to synthesize the endohedral nitrogen-fullerenes by ion implantation. N{sup +} beam was irradiated to a fullerene target with a specific energy and dose. As a result, we could observe the peak of N+C{sub 60} from targets after N{sup +} beam irradiation with TOF-SIMS and LDI-TOF-MS.

36 MATERIALS SCIENCE↗

Inverted organic solar cells comprising a solution-processed cesium fluoride interlayer

We investigate the influence of solution-processed cesium fluoride (CsF) interlayers on the performance of inverted polymer solar cells comprising a blend of poly(3-hexylthiophene-2,5-diyl):[6,6]-phenyl C{sub 61}-butyric acid methyl ester. The thickness of the CsF layer is optimized in terms of current-voltage characteristics by a variation of the solid content in solution. Capacitance-voltage characteristics reveal a shift of the built-in voltage at the cathode interface by about 0.3 V as compared to devices without a CsF layer, giving rise to an increase in open-circuit voltage by the same value. The vertical distribution of Cs{sup +} and F{sup +} ions is studied by secondary ion mass spectroscopy, indicating a strong diffusion of the alkaline fluoride into the organic layer stack.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electroplating hard magnetic SmCo for magnetic microactuator applications

Patterned SmCo thin films were electroplated from an aqueous solute containing glycine by using dc and pulse dc current on the beaker level. Micromolds prepared by photolithography allow an accurate pattern transfer for patterned deposition of the material. A flux guide of a magnetic microactuator was chosen as a pattern, and Al{sub 2}O{sub 3} was used as the substrate. Au and Cr were investigated as seed layer materials. The content of Sm in the SmCo films is strongly dependent on the applied cathodic current density. A relative Sm content of up to 13.8 at. % could be determined by energy dispersive x-ray (EDX) spectroscopy. The SmCo thin films were annealed at 560 deg. C in a vacuum oven. Vibrating sample magnetometer (VSM) measurements were applied to characterize the magnetic properties. This film features hard magnetic properties with an intrinsic coercivity H{sub ci} of up to 44 kA/m. Electron probe microanalysis (EPMA) measurements showed that up to 40 at. % of O may be integrated in these films. The phases in the deposited films were determined by applying X-ray diffraction (XRD) measurements. These films consist of a mixture of SmCo alloy, Sm oxide, and Co.

36 MATERIALS SCIENCE↗

Analysis of Interstitial Elements in Niobium with Secondary Ion Mass Spectrometry (SIMS)

Superconducting Radio Frequency (SRF) cavities provide enhanced efficiency and reduced energy utilization in present day particle accelerators. Niobium (Nb) is the material of choice for these cavities due to its high critical temperature and critical magnetic field. In order to understand why certain treatments, especially a low temperature bake, improve performance, it is important to study Nb surface characteristics and identify elemental contamination that can affect the performance of the cavity. H, C, O, and N are of interest because they are interstitial impurities in Nb. In earlier work, SIMS analysis using a CAMECA IMS-6F with Cs{sup +} primary beam showed that C and N were probably not significant factors impacting performance but there was a very high level of H in the Nb. Ion implants of C, N, O, and D into Nb provided quantification of C, N, O and indicated that D is very mobile in the Nb. Further analyses showed that heat treated Nb has lower levels of surface H than non heat treated Nb and subsequent removal of surface oxide by etching causes intake of H in a heat treated Nb sample. This result helps confirm the role of surface oxide as a hydrogen barrier. To further understand the oxide, Nb samples were anodized to obtain a thicker surface oxide and H and D were implanted into this oxide to check for the appearance of implant peaks. SIMS depth profile analyses were carried out and confirmed the presence of the implant shape for these elements in the oxide. Relative Sensitivity Factor (RSFs) could then be calculated for quantification of H in the oxide. Since the Nb matrix signal showed little change from the oxide to the substrate, the same RSF was used to estimate the H concentration in the Nb at 2x10{sup 22} atoms/cm{sup 3}(approximately 40% mole fraction H).

36 MATERIALS SCIENCE↗

The influence of impurities and planar defects on the infrared properties of silicon carbide films

Two cubic, single crystal silicon carbide (3C-SiC) films with similar thickness are shown to exhibit significantly different optical properties at mid-infrared wavelengths. Depth profiling by time-of-flight secondary ion mass spectroscopy indicates that these two films have substantially different n-type impurity concentrations that are responsible for the observed differences in optical absorption. The influence of impurities manifests as substantially different planar defect morphologies.

36 MATERIALS SCIENCE↗

Integration Of SIMS Into A General Purpose IBA Data Analysis Code

IBA techniques such as RBS, ERDA, NRA, or PIXE are highly complementary, and are often combined to maximize the extracted information. In particular, they have different sensitivities to various elements and probe different depth scales. The same is true for secondary ion mass spectrometry (SIMS), that can have much better detection limits for many species. Quantification of SIMS data normally requires careful calibration of the exact system being studied, and often the results are only semi-quantitative. Nevertheless, when SIMS is used together with other IBA techniques, it would be highly desirable to integrate the data analysis. We developed a routine to analyse SIMS data, and implemented it in NDF, a standard IBA data analysis code, that already supported RBS, ERDA, resonant and non-resonant NRA, and PIXE. Details of this new routine are presented in this work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular beam deposition of Al{sub 2}O{sub 3} on p-Ge(001)/Ge{sub 0.95}Sn{sub 0.05} heterostructure and impact of a Ge-cap interfacial layer

We investigated the molecular beam deposition of Al{sub 2}O{sub 3} on Ge{sub 0.95}Sn{sub 0.05} surface with and without an ultra thin Ge cap layer in between. We first studied the atomic configuration of both Ge{sub 1-x}Sn{sub x} and Ge/Ge{sub 1-x}Sn{sub x} surfaces after deoxidation by reflection high-energy electron diffraction and resulted, respectively, in a c(4x2) and (2x1) surface reconstructions. After in situ deposition of an Al{sub 2}O{sub 3} high-{kappa} gate dielectric we evidenced using time-of-flight secondary ion mass spectroscopy analyses that Sn diffusion was at the origin of high leakage current densities in the Ge{sub 1-x}Sn{sub x}/Al{sub 2}O{sub 3} gate stack. This damage could be avoided by inserting a thin 5-nm-thick Ge cap between the oxide and the Ge{sub 1-x}Sn{sub x} layer. Finally, metal-oxide-semiconductor capacitors on the Ge capped sample showed well-behaved capacitance-voltage (C-V) characteristics with interface trap density (D{sub it}) in the range of 10{sup 12} eV{sup -1} cm{sup -2} in mid gap and higher close to the valence band edge.

36 MATERIALS SCIENCE↗

Role of stable and metastable Mg-H complexes in p-type GaN for cw blue laser diodes

Secondary ion mass spectroscopy (SIMS) and capacitance-voltage measurements were combined to thoroughly study Mg doping in GaN layers grown by metal organic vapor phase epitaxy. First we found that the Mg steady-state incorporation regime occurs for a surface coverage of 0.3 monolayer. Additionally SIMS indicates that H incorporates proportionally with Mg until a certain [Mg] where [H] saturates. After thermal activation, [H] while being much lower still scales with [Mg]. These results suggest that H combines with Mg to form two different types of Mg-H complexes: a metastable one leading to the Mg acceptor after annealing, the other one (dominating at high [Mg]) being stable and electrically inactive. The obtained results allowed us optimizing doping conditions for blue laser diodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Secondary ions mass spectroscopy measurements of dopant impurities in highly stressed InGaN laser diodes

We performed a systematic secondary ions mass spectroscopy (SIMS) study of dopant impurities in life-time stressed InGaN laser devices in order to investigate the main degradation mechanism that is observed in nitride laser diodes. A continuous wave (cw) current density of 3 kA/cm{sup 2} was applied to InGaN laser diodes over an extended period of time and we observed the characteristic square root degradation of optical power. We compared the SIMS profiles of Mg, H, and Si impurities in the aged devices and observe that the impurities are remarkably stable over 10 000 h of cw operation. Nor is there any SIMS evidence of p-contact metals penetrating into the semiconductor material. Thus our SIMS results are contrary to what one would expect for impurity diffusion causing the observed square root degradation characteristic.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Negative Ions for Emerging Interdisciplinary Applications

In many applications related to ion beam-materials interactions negative ions are particularly desirable due to its merit to yield a very low surface charge-up voltage, {approx} a few volts, for both electrically isolated surfaces and insulators. Some important applications pertaining to ion beam-material interactions include surface analysis by secondary ion mass spectrometry (SIMS), voltage-contrast microscopy for semiconductor device inspection, materials processing, and ion beam lithography. These applications primarily require vacuum environments. On the other hand, a distinct area of activities constitutes formation of ions and ion transport in ambient environmental conditions, i.e., at atmospheric pressures. In this context, ion mobility spectrometry (IMS) is an important analytical device that uses negative ions and operates at ambient conditions. IMS is widely used in both physical and biological sciences including monitoring environmental conditions, security screening and disease detection. This article highlights several critical issues related to the ionization sources and ion transport in IMS. Additionally, the critical issues related to ion sources, transport and focusing are discussed in the context of SIMS with sub-micrometer spatial resolution.

36 MATERIALS SCIENCE↗

Determination of secondary ion mass spectrometry relative sensitivity factors for polar and non-polar ZnO

Zinc oxide (ZnO) is regarded as a promising material for optoelectronic devices, due to its electronic properties. Solely, the difficulty in obtaining p-type ZnO impedes further progress. In this connection, the identification and quantification of impurities is a major demand. For quantitative information using secondary ion mass spectrometry (SIMS), so-called relative sensitivity factors (RSF) are mandatory. Such conversion factors did not yet exist for ZnO. In this work, we present the determined RSF values for ZnO using primary (ion implanted) as well as secondary (bulk doped) standards. These RSFs have been applied to commercially available ZnO substrates of different surface termination (a-plane, Zn-face, and O-face) to quantify the contained impurities. Although these ZnO substrates originate from the same single-crystal, we observe discrepancies in the impurity concentrations. These results cannot be attributed to surface termination dependent RSF values for ZnO.