Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mix Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Modeling the AC Power Flow Equations with Optimally Compact Neural Networks: Application to Unit Commitment

Nonlinear power flow constraints render a variety of power system optimization problems computationally intractable. Emerging research shows, however, that the nonlinear AC power flow equations can be successfully modeled using neural networks. These neural networks can be exactly transformed into mixed integer linear programs and embedded inside challenging optimization problems, thus replacing nonlinearities that are intractable for many applications with tractable piecewise linear approximations. Such approaches, though, suffer from an explosion of the number of binary variables needed to represent the neural network. Accordingly, this paper develops a technique for training an "optimally compact'' neural network, i.e., one that can represent the power flow equations with a sufficiently high degree of accuracy while still maintaining a tractable number of binary variables. We demonstrate the use of this neural network as an approximator of the nonlinear power flow equations by embedding it in the AC unit commitment problem, transforming the problem from a mixed integer nonlinear program into a more manageable mixed integer linear program. We use the 14-, 57-, and 89-bus networks as test cases and compare the AC-feasibility of commitment decisions resulting from the neural network, DC, and linearized power flow approximations. Our results show that the neural network model outperforms both the DC and linearized power flow approximations when embedded in the unit commitment problem. The neural network formulation most often selects a feasible unit commitment schedule, and furthermore, it only s

AC power flow↗

Testing of an Integrated Nitrogen Oxide Catcher

A gas-purification system with maximum capacity 50 m{sup 3}/h was developed, fabricated, and tested to catch nitrogen oxides released during hydrometallurgical processing of spent fuel from the BREST reactor. To catch nitrogen oxides, the setup employs water aerosols introduced into the gas duct; it also includes a tank for mixing water aerosols with gas flow, coarse and fine filters, and BRUNS and SMOG apparatus. The filtering complex (mixing tank, FCGO and FAROS filters) gave 72–76% conversion of nitrogen dioxide with initial concentration of 11 g/m{sup 3}; this confirmed that aerosol fiberglass filters can be used to catch nitrogen dioxide. In the tests, the complex of units comprising the setup gave 95.4–98.5% conversion of nitrogen oxide with initial concentration 11–50 g/m{sup 3}. After the design of the mixing tanks is improved and remote extraction of the cartridges of the gas purification apparatus is organized, the tested gas purification setup can be used in radiochemical production.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental study on effects of geologic heterogeneity in enhancing dissolution trapping of supercritical CO 2

Abstract Dissolution trapping is one of the primary mechanisms that enhance the storage security of supercritical carbon dioxide (scCO 2 ) in saline geologic formations. When scCO 2 dissolves in formation brine produces an aqueous solution that is denser than formation brine, which leads to convective mixing driven by gravitational instabilities. Convective mixing can enhance the dissolution of CO 2 and thus it can contribute to stable trapping of dissolved CO 2 . However, in the presence of geologic heterogeneities, diffusive mixing may also contribute to dissolution trapping. The effects of heterogeneity on mixing and its contribution to stable trapping are not well understood. The goal of this experimental study is to investigate the effects of geologic heterogeneity on mixing and stable trapping of dissolved CO 2 . Homogeneous and heterogeneous media experiments were conducted in a two‐dimensional test tank with various packing configurations using surrogates for scCO 2 (water) and brine (propylene glycol) under ambient pressure and temperature conditions. The results show that the density‐driven flow in heterogeneous formations may not always cause significant convective mixing especially in layered systems containing low‐permeability zones. In homogeneous formations, density‐driven fingering enhances both storage in the deeper parts of the formation and contact between the host rock and dissolved CO 2 for the potential mineralization. On the other hand, for layered systems, dissolved CO 2 becomes immobilized in low‐permeability zones with low‐diffusion rates, which reduces the risk of leakage through any fault or fracture. Both cases contribute to the permanence of the dissolved plume in the formation.

Agartan, Elif↗

Model of non-stationary, inhomogeneous turbulence

Here, we compare results from a spectral model for non-stationary, inhomogeneous turbulence (Besnard et al. in Theor Comp Fluid Dyn 8:1–35, 1996) with direct numerical simulation (DNS) data of a shear-free mixing layer (SFML) (Tordella et al. in Phys Rev E 77:016309, 2008). The SFML is used as a test case in which the efficacy of the model closure for the physical-space transport of the fluid velocity field can be tested in a flow with inhomogeneity, without the additional complexity of mean-flow coupling. The model is able to capture certain features of the SFML quite well for intermediate to long times, including the evolution of the mixing-layer width and turbulent kinetic energy. At short-times, and for more sensitive statistics such as the generation of the velocity field anisotropy, the model is less accurate. We propose two possible causes for the discrepancies. The first is the local approximation to the pressure-transport and the second is the a priori spherical averaging used to reduce the dimensionality of the solution space of the model, from wavevector to wavenumber space. DNS data are then used to gauge the relative importance of both possible deficiencies in the model.

42 ENGINEERING↗

Implications of D{sup 0}-D{sup 0} mixing for new physics

We provide a comprehensive, up-to-date analysis of possible new physics contributions to the mass difference {delta}M{sub D} in D{sup 0}-D{sup 0} mixing. We consider the most general low-energy effective Hamiltonian and include leading-order QCD running of effective operators. We then explore an extensive list of possible new physics models that can generate these operators, which we organize as including extra fermions, extra gauge bosons, extra scalars, extra space dimensions and extra symmetries. For each model we place restrictions on the allowed parameter space using the recent evidence for observation of D meson mixing. In many scenarios, we find strong constraints that surpass those from other search techniques and provide an important test of flavor-changing neutral currents in the up-quark sector. We also review the recent BABAR and Belle findings, and describe the current status of the standard model predictions of D{sup 0}-D{sup 0} mixing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Final Report for Intravenous Fluid Generation (IVGEN) Spaceflight Experiment

NASA designed and operated the Intravenous Fluid Generation (IVGEN) experiment onboard the International Space Station (ISS), Increment 23/24, during May 2010. This hardware was a demonstration experiment to generate intravenous (IV) fluid from ISS Water Processing Assembly (WPA) potable water using a water purification technique and pharmaceutical mixing system. The IVGEN experiment utilizes a deionizing resin bed to remove contaminants from feedstock water to a purity level that meets the standards of the United States Pharmacopeia (USP), the governing body for pharmaceuticals in the United States. The water was then introduced into an IV bag where the fluid was mixed with USP-grade crystalline salt to produce USP normal saline (NS). Inline conductivity sensors quantified the feedstock water quality, output water purity, and NS mixing uniformity. Six 1.5-L bags of purified water were produced. Two of these bags were mixed with sodium chloride to make 0.9 percent NS solution. These two bags were returned to Earth to test for compliance with USP requirements. On-orbit results indicated that all of the experimental success criteria were met with the exception of the salt concentration. Problems with a large air bubble in the first bag of purified water resulted in a slightly concentrated saline solution of 117 percent of the target value of 0.9 g/L. The second bag had an inadequate amount of salt premeasured into the mixing bag resulting in a slightly deficient salt concentration of 93.8 percent of the target value. The USP permits a range from 95 to 105 percent of the target value. The testing plans for improvements for an operational system are also presented.

McQuillen, John B.↗

Double noding technique for mixed mode crack propagation studies

A simple dynamic finite element algorithm for analyzing a propagating mixed mode crack tip is presented. A double noding technique, which can be easily incorporated into existing dynamic finite element codes, is used together with a corrected J integral to extract modes I and II dynamic stress intensity factors of a propagating crack. The utility of the procedure is demonstrated by analyzing test problems involving a mode I central crack propagating in a plate subjected to uniaxial tension, a mixed mode I and II stationary, slanted central crack in a plate subjected to uniaxial impact loading, and a mixed mode I and II extending, slanted single edge crack in a plate subjected to uniaxial tension.

Liaw, B. M.↗

Double noding technique for mixed mode crack propagation studies

A simple dynamic finite element algorithm for analyzing a propagating mixed mode crack tip is presented. A double noding technique, which can be easily incorporated into existing dynamic finite element codes, is used together with a corrected J integral to extract modes I and II dynamic stress intensity factors of a propagating crack. The utility of the procedure is demonstrated by analyzing test problems involving a mode I central crack propagating in a plate subjected to uniaxial tension, a mixed mode I and II stationary, slanted central crack in a plate subjected to uniaxial impact loading, and a mixed mode I and II extending, slanted single edge crack in a plate subjected to uniaxial tension. Previously announced in STAR as N83-13491

Liaw, B. M.↗

Development of an Empirical Methods for Predicting Jet Mixing Noise of Cold Flow Rectangular Jets

This report presents an empirical method for predicting the jet mixing noise levels of cold flow rectangular jets. The report presents a detailed analysis of the methodology used in development of the prediction method. The empirical correlations used are based on narrow band acoustic data for cold flow rectangular model nozzle tests conducted in the NASA Langley Jet Noise Laboratory. There were 20 separate nozzle test operating conditions. For each operating condition 60 Hz bandwidth microphone measurements were made over a frequency range from 0 to 60,000 Hz. Measurements were performed at 16 polar directivity angles ranging from 45 degrees to 157.5 degrees. At each polar directivity angle, measurements were made at 9 azimuth directivity angles. The report shows the methods employed to remove screech tones and shock noise from the data in order to obtain the jet mixing noise component. The jet mixing noise was defined in terms of one third octave band spectral content, polar and azimuth directivity, and overall power level. Empirical correlations were performed over the range of test conditions to define each of these jet mixing noise parameters as a function of aspect ratio, jet velocity, and polar and azimuth directivity angles. The report presents the method for predicting the overall power level, the average polar directivity, the azimuth directivity and the location and shape of the spectra for jet mixing noise of cold flow rectangular jets.

Russell, James W.↗

An experimental investigation of turbulent boundary layers along curved surfaces

A curved wall tunnel was designed, and an equilibrium turbulent boundary layer was set up on the straight section preceding the curved test section. Turbulent boundary layer flows with uniform and adverse pressure distributions along convex and concave walls were investigated. Hot-wire measurements along the convex surface indicated that turbulent mixing between fluid layers was very much reduced. However, the law of the wall held and the skin friction, thus determined, correlated well with other measurements. Hot-wire measurements along the concave test wall revealed a system of longitudinal vortices inside the boundary layer and confirmed that concave curvature enhances mixing. A self-consistent set of turbulent boundary layer equations for flows along curved surfaces was derived together with a modified eddy viscosity. Solution of these equations together with the modified eddy viscosity gave results that correlated well with the present data on flows along the convex surface with arbitrary pressure distribution. However, it could only be used to predict the mean characteristics of the flow along concave walls because of the existence of the system of longitudinal vortices inside the boundary layer.

So, R. M. C.↗

Rapid mix concepts for low emission combustors in gas turbine engines

NASA LeRC has identified the Rich burn/Quick mix/Lean burn (RQL) combustor as a potential gas turbine combustor concept to reduce NOx emissions in High Speed Civil Transport (HSCT) aircraft. To demonstrate reduced NOx levels, NASA LeRC soon will test a flametube version of an RQL combustor. The critical technology needed for the RQL combustor is a method of quickly mixing combustion air with rich burn gases. Two concepts were proposed to enhance jet mixing in a circular cross-section: the Asymmetric Jet Penetration (AJP) concept; and the Lobed Mixer (LM) concept. In Phase 1, two preliminary configurations of the AJP concept were compared with a conventional 12-jet radial-inflow slot design. The configurations were screened using an advanced 3-D Computational Fluid Dynamics (CFD) code named REFLEQS. Both non-reacting and reacting analyses were performed. For an objective comparison, the conventional design was optimized by parametric variation of the jet-to-mainstream momentum flux (J) ratio. The optimum J was then employed in the AJP simulations. Results showed that the three-jet AJP configuration was superior in overall mixedness compared to the conventional design. However, in regards to NOx emissions, the AJP configuration was inferior. The higher emission level for AJP was caused by a single hot spot located in the wake of the central jet as it entered the combustor. Ways of maintaining good mixedness while eliminating the hot spot were identified for Phase 2 study. Overall, Phase 1 showed the viability of using CFD analyses to evaluate quick-mix concepts. A high probability exists that advancing mixing concepts will reduce NOx emissions in RQL combustors, and should be explored in Phase 2, by parallel numerical and experimental work.

Talpallikar, Milind V.↗

Ice-Crystal Icing Accretion Studies at the NASA Propulsion Systems Laboratory

This paper describes an ice-crystal icing experiment conducted at the NASA Propulsion System Laboratory during June 2018. This test produced ice shape data on an airfoil for different test conditions similar to those inside the compressor region of a turbo-fan jet engine. Mixed-phase icing conditions were generated by partially freezing out a water spray using the relative humidity of flow as the primary parameter to control freeze-out. The paper presents the ice shape data and associated conditions which include pressure, velocity, temperature, humidity, total water content, melt ratio, and particle size distribution. The test featured a new instrument traversing system which allowed surveys of the flow and cloud. The purpose of this work was to provide experimental ice shape data and associated conditions to help develop and validate ice-crystal icing accretion models. The results support previous experimental observations of a minimum melt-ratio threshold for accretion to occur as well as the existence of a plateau region where the icing severity is high for a range of melt ratios. However, a maximum limit for melt ratio, which is suggested in the ice crystal icing literature, was not observed perhaps complicated by the potential for some supercooling of the water at these conditions.

Engine Icing↗

New Formulation of Cast Stone for {sup 99}Tc Immobilization in Sulfate Rich Secondary Waste Stream - 16098

A low-temperature, cementitious waste form called Cast Stone (or grout) has been selected for solidification of the Effluent Treatment Facility (ETF)-treated wastes at the Hanford Site. Because the waste stream to be solidified may be relatively high in sulfate, the current Cast Stone dry blend formulation with ordinary Portland cement (OPC), fly ash (FA), and blast furnace slag (BFS) (47% BFS, 45% FA, and 8% OPC) may not be adequate. Thus a new formulation, called secondary waste grout, was proposed and tested. The secondary waste grout uses hydrated lime [Ca(OH){sub 2}] to tie up the sulfate initially such that ettringite [Ca{sub 6}Al{sub 2}(SO{sub 4}){sub 3}(OH){sub 12}.26(H{sub 2}O)] forms rapidly instead of forming as the cementitious waste form cures. Three different liquid waste simulants (242-A evaporator, Environmental Restoration Disposal Facility [ERDF] leachates, and Hanford Tank Waste Treatment and Immobilization Plant [WTP] off-gas condensates) were prepared and solidified using this new dry blend formulation. Baseline grout dry mixes were 20 wt% hydrated lime (HL), 35 wt% OPC, and 45 wt% BFS, and two different water-to-dry mix (w/dm) ratios (0.5 and 0.6) of free water mass to mass of dry blend were tested. After curing for a minimum of 28 days, the grout solidified waste forms were characterized and used for Tc leachability testing using the EPA 1315 Method. X-ray diffraction analysis confirmed that ∼12-15% of ettringite was formed in early stage of 28-day curing for the grouts prepared with the high sulfate WTP simulant and HL addition. In addition, the new formulation of secondary waste grout prepared with HL (20%), OPC (35%), and BFS (45%) at either 0.5 or 0.6 water to dry mix ratio yields higher average Tc interval leachability index (LI) values (12.5 to 13.9) after 28 to 90 days of leaching using deionized water, which is higher than the desired {sup 99}Tc LI value of 12 for grout destined for burial in the Integrated Disposal Facility at the Hanford Site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sequential Inference of Hospitalization Electronic Health Records Using Probabilistic Models

In the dynamic hospital setting, decision support can be a valuable tool for improving patient outcomes. Data-driven inference of future outcomes is challenging in this dynamic setting, where long sequences such as laboratory tests and medications are updated frequently. This is due in part to heterogeneity of data types and mixed-sequence types contained in variable length sequences. In this work we design a probabilistic unsupervised model for multiple arbitrary-length sequences contained in hospitalization Electronic Health Record (EHR) data. The model uses a latent variable structure and captures complex relationships between medications, diagnoses, laboratory tests, neurological assessments, and medications. It can be trained on original data, without requiring any lossy transformations or time binning. Inference algorithms are derived that use partial data to infer properties of the complete sequences, including their length and presence of specific values. We train this model on data from subjects receiving medical care in the Kaiser Permanente Northern California integrated healthcare delivery system. The results are evaluated against held-out data for predicting the length of sequences and presence of Intensive Care Unit (ICU) in hospitalization bed sequences. Our method outperforms a baseline approach, showing that in these experiments the trained model captures information in the sequences that is informative of their future values.

97 MATHEMATICS AND COMPUTING↗

The Trash Compaction Processing Systems (TCPS) Ground Unit Control Sample Testing

The Trash Compaction Processing System (TCPS) is being developed by NASA and Sierra Space to process crew trash for long-duration missions. The system compacts and thermally processes mixed spacecraft waste to reduce volume and stabilize the material while managing gas and liquid effluents. A Ground Unit (GU) located at Sierra Space in Madison, Wisconsin was used to run a series of tests using standardized control samples representing different trash conditions, including nominal, high liquid, high cloth, benign, and foam. Gas grab samples were collected during processing and analyzed to identify the compounds present in the effluent stream and compare the concentrations to the NASA spacecraft maximum allowable concentrations (SMACs). Additional testing included odor testing at White Sands Test Facility, aerosol measurements, microbiology, and tile characterization. Overall, the compounds detected in the gas samples were well below the SMAC limits for all trash models tested. The results from this testing are being used to help guide the verification approach and test planning for the TCPS Flight Unit that is planned for on-orbit testing on the International Space Station.

Control Samples↗

Mixing Study for JT-71/72 Tanks

All modeling calculations for the mixing operations of miscible fluids contained in HB-Line tanks, JT-71/72, were performed by taking a three-dimensional Computational Fluid Dynamics (CFD) approach. The CFD modeling results were benchmarked against the literature results and the previous SRNL test results to validate the model. Final performance calculations were performed by using the validated model to quantify the mixing time for the HB-Line tanks. The mixing study results for the JT-71/72 tanks show that, for the cases modeled, the mixing time required for blending of the tank contents is no more than 35 minutes, which is well below 2.5 hours of recirculation pump operation. Therefore, the results demonstrate the adequacy of 2.5 hours’ mixing time of the tank contents by one recirculation pump to get well mixed.

42 ENGINEERING↗

BLENDING ANALYSIS FOR RADIOACTIVE SALT WASTE PROCESSING FACILITY

Savannah River National Laboratory (SRNL) evaluated methods to mix and blend the contents of the blend tanks to ensure the contents are properly blended before they are transferred from the blend tank such as Tank 21 and Tank 24 to the Salt Waste Processing Facility (SWPF) feed tank. The tank contents consist of three forms: dissolved salt solution, other waste salt solutions, and sludge containing settled solids. This paper focuses on developing the computational model and estimating the operation time of submersible slurry pump when the tank contents are adequately blended prior to their transfer to the SWPF facility. A three-dimensional computational fluid dynamics approach was taken by using the full scale configuration of SRS Type-IV tank, Tank 21H. Major solid obstructions such as the tank wall boundary, the transfer pump column, and three slurry pump housings including one active and two inactive pumps were included in the mixing performance model. Basic flow pattern results predicted by the computational model were benchmarked against the SRNL test results and literature data. Tank 21 is a waste tank that is used to prepare batches of salt feed for SWPF. The salt feed must be a homogeneous solution satisfying the acceptance criterion of the solids entrainment during transfer operation. The work scope described here consists of two modeling areas. They are the steady state flow pattern calculations before the addition of acid solution for tank blending operation and the transient mixing analysis during miscible liquid blending operation. The transient blending calculations were performed by using the 95% homogeneity criterion for the entire liquid domain of the tank. The initial conditions for the entire modeling domain were based on the steady-state flow pattern results with zero second phase concentration. The performance model was also benchmarked against the SRNL test results and literature data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coulomb branches with complex singularities

We construct 4d superconformal field theories (SCFTs) whose Coulomb branches have singular complex structures. This implies, in particular, that their Coulomb branch coordinate rings are not freely generated. Our construction also gives examples of distinct SCFTs which have identical moduli space (Coulomb, Higgs, and mixed branch) geometries. These SCFTs thus provide an interesting arena in which to test the relationship between moduli space geometries and conformal field theory data. Here we construct these SCFTs by gauging certain discrete global symmetries of N = 4 superYang-Mills (sYM) theories. In the simplest cases, these discrete symmetries are outer automorphisms of the sYM gauge group, and so these theories have lagrangian descriptions as N = 4 sYM theories with disconnected gauge groups.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗