Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mix Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Conversion of batch to molten glass, I: Volume expansion

Batches designed to simulate nuclear high-level waste glass were compressed into pellets that were heated at a rate of 5 K/min and photographed to obtain the profile area as a function of temperature. Three types of batches were prepared with different nitrate-carbonate ratios. To determine the impact of the heat supply by an exothermic reaction and the batch expansion, the nitrated batches were prepared with varying addition of sucrose. To obtain the impact of the grain size of the quartz component, the mixed nitrate-carbonate batches were prepared with silica particles ranging in size from 5 µm to 195 µm. One batch containing only carbonates was also tested. Sucrose addition had little effect on the batch expansion, while the size of silica was very influential. The 5-μm grains had a strongest effect, causing the generation of both primary and secondary foam, whereas only secondary foam was produced in batches with grains of 45 µm and larger. The retention of gases evolved as the batch melts creates primary foam. Gases evolved from oxidation-reduction reactions once the batch has melted produce secondary foam. We suggest that the viscosity of the melt and the amount of gas evolved are the main influences on foam production. As more gas is produced in the melt and as the glass becomes less viscous, the bubbles of gas coalesce into larger and larger cavities, until the glass can no longer contain the bubbles and they burst, causing the foam to collapse.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The MUSE beamline calorimeter

The MUon Scattering Experiment (MUSE) was motivated by the proton radius puzzle arising from the discrepancy between muonic hydrogen spectroscopy and electron–proton measurements. The MUSE physics goals also include testing lepton universality, precisely measuring two-photon exchange contribution, and testing radiative corrections. MUSE addresses these physics goals through simultaneous measurement of high precision cross sections for electron–proton and muon–proton scattering using a mixed-species beam. The experiment will run at both positive and negative beam polarities. Measuring precise cross sections requires understanding both the incident beam energy and the radiative corrections. For this purpose, a lead-glass calorimeter was installed at the end of the beam line in the MUSE detector system. Here, in this article, we discuss the detector specifications, calibration and performance. We demonstrate that the detector performance is well reproduced by simulation, and meets experimental requirements.

Calorimeter↗

Improved Lubricating Performance by Combining Oil-Soluble Hairy Silica Nanoparticles and an Ionic Liquid as an Additive for a Synthetic Base Oil

This article reports on improved lubricating performance by combining oil-soluble poly(lauryl methacrylate) brush-grafted silica nanoparticles (hairy NPs or HNP) and an oil-miscible phosphonium-phosphate ionic liquid (IL) as a friction-reducing additive for a polyalphaolefin (PAO) oil. The HNP was synthesized by surface-initiated reversible addition–fragmentation chain transfer polymerization. At a total concentration of 2% and sufficiently high individual concentrations for HNP and IL in PAO, high-contact stress, ball-on-flat reciprocating tribological tests showed that the friction decreased by up to 23% compared with 2% HNP alone in PAO and by up to 35% compared to the PAO mixed with 2% IL. Scanning electron microscopy, energy-dispersive X-ray spectroscopy, and X-ray photoelectron spectroscopy (XPS) analysis revealed that the tribofilm formed from the PAO containing 1% HNP + 1% IL was enriched with both Si and P, indicating that both hairy NPs and IL were involved in the tribochemical reactions. In addition, the O 1s and Si 2p peaks in the core-level XPS spectra exhibited significant shifts for the mixture of 1% HNP + 1% IL compared to those for 2% HNP, suggesting the possible formation of new covalent bonds. These results indicated that HNP and IL reacted with each other and also with the metal substrate during the rubbing process, which likely strengthened the tribofilm and its bonding with the substrate and thus further improved the lubrication.

36 MATERIALS SCIENCE↗

Evaluation of hybrid sol-gel incorporated with nanoparticles as nano paint

A coating with self-cleaning characteristics has been developed using a TiO{sub 2}/SiO{sub 2} hybrid sol-gel, TiO{sub 2} nanoparticles and organosilicate nanoparticles (OSNP). A patented technology of the hybrid sol-gel and OSNP was combined with TiO{sub 2} nanoparticles to create the surface chemistry for self-cleaning. Two synthesis methods have been developed to prepare TiO{sub 2} nanoparticles (NPs), resulting in the enhancement of local paint by the addition of anatase and rutile TiO{sub 2} phases. The NPs size as determined by Dynamic Light Scattering (DLS) ranges within of (3-4) and (20-42) nm, which was also confirmed by Scanning Electron Microscopy (SEM). The nanoparticles showed surface charge (zeta-potential, ζ) of +35 and +25.62 mV for the methods, respectively, and ζ values of +41.31 and 34.02 mV for anatase and rutile phases, respectively. The NPs were mixed with the coating solution (i.e., hybrid sol-gel and OSNP) in different concentrations and thin films were prepared by spin coating. Self-cleaning tests were performed using Rhodamine B (RhB) as a pollution indicator. The effect of UV-irradiation on the films was also studied. Anatase and rutile incorporated as a mixture with different ratios in local paint and washability as well as a contrast ratio tests were performed. It was found that the addition of TiO{sub 2} NPs in combination with irradiation show a great enhancement of RhB degradation (1%) wt. with a decrease in contact angle and improved washability.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

THREE-DIMENSIONAL MOVING-MESH SIMULATIONS OF GALACTIC CENTER CLOUD G2

Using three-dimensional, moving-mesh simulations, we investigate the future evolution of the recently discovered gas cloud G2 traveling through the galactic center. We consider the case of a spherical cloud initially in pressure equilibrium with the background. Our suite of simulations explores the following parameters: the equation of state, radial profiles of the background gas, and start times for the evolution. Our primary focus is on how the fate of this cloud will affect the future activity of Sgr A*. From our simulations we expect an average feeding rate in the range of (5-19) Multiplication-Sign 10{sup -8} M {sub Sun} yr{sup -1} beginning in 2013 and lasting for at least 7 years (our simulations stop in year 2020). The accretion varies by less than a factor of three on timescales {<=}1 month, and shows no more than a factor of 10 difference between the maximum and minimum observed rates within any given model. These rates are comparable to the current estimated accretion rate in the immediate vicinity of Sgr A*, although they represent only a small ({approx}< 5%) increase over the current expected feeding rate at the effective inner boundary of our simulations (r = 750, R{sub S} Almost-Equal-To 10{sup 15} cm), where R{sub S} is the Schwarzschild radius of the black hole. Therefore, the breakup of cloud G2 may have only a minimal effect on the brightness and variability of Sgr A* over the next decade. This is because current models of the galactic center predict that most of the gas will be caught up in outflows. However, if the accreted G2 material can remain cold, it may not mix well with the hot, diffuse background gas, and instead accrete efficiently onto Sgr A*. Further observations of G2 will give us an unprecedented opportunity to test this idea. The breakup of the cloud itself may also be observable. By tracking the amount of cloud energy that is dissipated during our simulations, we are able to get a rough estimate of the luminosity associated with its tidal disruption; we find values of a few 10{sup 36} erg s{sup -1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Utilizing the maximum likelihood estimator for flow analysis

We explore the possibility of evaluating flow harmonics by employing the maximum likelihood estimator (MLE). For a given finite multiplicity, the MLE simultaneously furnishes estimations for all the parameters of the underlying distribution function while efficiently suppressing the variance of measures. Also, the method provides a means to assess a specific class of mixed harmonics, which is not straightforwardly feasible by the approaches primarily based on particle correlations. The results are analyzed using the Wald, likelihood ratio, and score tests of hypotheses. Besides, the resultant flow harmonics obtained using MLE are compared with those derived using particle correlations and event plane methods. Here, the dependencies of extracted flow harmonics on the multiplicity of individual events and the total number of events are analyzed. It is shown that the proposed approach works efficiently to deal with the deficiency in detector acceptability. Moreover, we elaborate on a fictitious scenario where the event plane is not a well-defined quantity in the distribution function. For the latter case, the MLE is shown to largely perform better than the two-particle correlation estimator. In this regard, one concludes that the MLE furnishes a meaningful alternative to the existing approaches for flow analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Confinement, quark mass functions, and spontaneous chiral symmetry breaking in Minkowski space

We formulate the covariant equations for quark-antiquark bound states in Minkowski space in the framework of the Covariant Spectator Theory. The quark propagators are dressed with the same kernel that describes the interaction between different quarks. We show that these equations are charge conjugation invariant, and that in the chiral limit of vanishing bare quark mass, a massless pseudoscalar bound state is produced in a Nambu--Jona-Lasinio (NJL) mechanism, which is associated with the Goldstone boson of spontaneous chiral symmetry breaking. In this introductory paper we test the formalism by using a simplified kernel consisting of a momentum-space $\delta$-function with a vector Lorentz structure, to which one adds a mixed scalar and vector confining interaction. The scalar part of the confining interaction is not chirally invariant by itself, but decouples from the equations in the chiral limit and therefore allows the NJL mechanism to work. With this model we calculate the quark mass function, and we compare our Minkowski-space results to LQCD data obtained in Euclidean space. In a companion paper we apply this formalism to a calculation of the pion form factor.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Approach for Configuring a Standardized Vessel for Processing Radioactive Waste Slurries

A standardized vessel design is being considered at the Waste Treatment and Immobilization Plant (WTP) that is under construction at Hanford, Washington. The standardized vessel design will be used for storing, blending, and chemical processing of slurries that exhibit a variable process feed including Newtonian to non-Newtonian rheologies over a range of solids loadings. Developing a standardized vessel is advantageous and reduces the testing required to evaluate the performance of the design. The objectives of this paper are to: 1) present a design strategy for developing a standard vessel mixing system design for the pretreatment portion of the waste treatment plant that must process rheologically and physically challenging process streams, 2) identify performance criteria that the design for the standard vessel must satisfy, 3) present parameters that are to be used for assessing the performance criteria, and 4) describe operation of the selected technology. Vessel design performance will be assessed for both Newtonian and non-Newtonian simulants which represent a range of waste types expected during operation. Desired conditions for the vessel operations are the ability to shear the slurry so that flammable gas does not accumulate within the vessel, that settled solids will be mobilized, that contents can be blended, and that contents can be transferred from the vessel. A strategy is presented for adjusting the vessel configuration to ensure that all these conditions are met.

pulse jet mixing↗

A novel computer-aided lung nodule detection system for CT images

Purpose: The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. Methods: The CAD system was trained and tested on images from the publicly available Lung Image Database Consortium (LIDC) on the National Cancer Institute website. The detection stage of the system consists of a nodule segmentation method based on nodule and vessel enhancement filters and a computed divergence feature to locate the centers of the nodule clusters. In the subsequent classification stage, invariant features, defined on a gauge coordinates system, are used to differentiate between real nodules and some forms of blood vessels that are easily generating false positive detections. The performance of the novel feature-selective classifier based on genetic algorithms and artificial neural networks (ANNs) is compared with that of two other established classifiers, namely, support vector machines (SVMs) and fixed-topology neural networks. A set of 235 randomly selected cases from the LIDC database was used to train the CAD system. The system has been tested on 125 independent cases from the LIDC database. Results: The overall performance of the fixed-topology ANN classifier slightly exceeds that of the other classifiers, provided the number of internal ANN nodes is chosen well. Making educated guesses about the number of internal ANN nodes is not needed in the new feature-selective classifier, and therefore this classifier remains interesting due to its flexibility and adaptability to the complexity of the classification problem to be solved. Our fixed-topology ANN classifier with 11 hidden nodes reaches a detection sensitivity of 87.5% with an average of four false positives per scan, for nodules with diameter greater than or equal to 3 mm. Analysis of the false positive items reveals that a considerable proportion (18%) of them are smaller nodules, less than 3 mm in diameter. Conclusions: A complete CAD system incorporating novel features is presented, and its performance with three separate classifiers is compared and analyzed. The overall performance of our CAD system equipped with any of the three classifiers is well with respect to other methods described in literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Macro-Batch Qualification Strategy for the Hanford Tank Waste Treatment and Immobilization Plant

The Savannah River National Laboratory (SRNL) has evaluated the existing waste feed qualification strategy for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) based on experience from the Savannah River Site (SRS) Defense Waste Processing Facility (DWPF) waste qualification program. The current waste qualification programs for each of the sites are discussed in the report to provide a baseline for comparison. Recommendations on strategies are then provided that could be implemented at Hanford based on the successful Macrobatch qualification strategy utilized at SRS to reduce the risk of processing upsets or the production of a staged waste campaign that does not meet the processing requirements of the WTP. Considerations included the baseline WTP process, as well as options involving Direct High Level Waste (HLW) and Low Activity Waste (LAW) processing, and the potential use of a Tank Waste Characterization and Staging Facility (TWCSF). The main objectives of the Hanford waste feed qualification program are to demonstrate compliance with the Waste Acceptance Criteria (WAC), determine waste processability, and demonstrate unit operations at a laboratory scale. Risks to acceptability and successful implementation of this program, as compared to the DWPF Macro-Batch qualification strategy, include: Limitations of mixing/blending capability of the Hanford Tank Farm; The complexity of unit operations (i.e., multiple chemical and mechanical separations processes) involved in the WTP pretreatment qualification process; The need to account for effects of blending of LAW and HLW streams, as well as a recycle stream, within the PT unit operations; and The reliance on only a single set of unit operations demonstrations with the radioactive qualification sample. This later limitation is further complicated because of the 180-day completion requirement for all of the necessary waste feed qualification steps. The primary recommendations/changes include the following: Collection and characterization of samples for relevant process analytes from the tanks to be blended during the staging process; Initiation of qualification activities earlier in the staging process to optimize the campaign composition through evaluation from both a processing and glass composition perspective; Definition of the parameters that are important for processing in the WTP facilities (unit operations) across the anticipated range of wastes and as they relate to qualification-scale equipment; Performance of limited testing with simulants ahead of the waste feed qualification sample demonstration as needed to determine the available processing window for that campaign; and Demonstration of sufficient mixing in the staging tank to show that the waste qualification sample chemical and physical properties are representative of the transfers to be made to WTP. Potential flowcharts for derivatives of the Hanford waste feed qualification process are also provided in this report. While these recommendations are an extension of the existing WTP waste qualification program, they are more in line with the processes currently performed for SRS. The implementation of these processes at SRS has been shown to offer flexibility for processing, having identified potential processing issues ahead of the qualification or facility processing, and having provided opportunity to optimize waste loading and throughput in the DWPF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CFD Analysis of RLUOB Zone 1 HEPA Filter Plenum and Testing Manifolds

The purpose of this computational fluid dynamics (CFD) analysis is to ensure that Camfil Farr’s upstream and downstream injection and sampling manifolds can meet or exceed the requirements outlined in the ASME AG-1 1997 a(2000) Code on Nuclear Air and Gas Treatment for the testing of HEPA and adsorbent filters. This paper will present a numerical simulation of airflow in the Radiological Laboratory Utility Office Building (RLUOB) zone 1 HEPA filter plenum and testing manifolds using the commercial CFD software ANSYS FLUENT 2020R1. The CFD analysis focuses on the investigation of the air flow distribution and air-aerosol mixing uniformity. The evaluation was done for all steps of the modeling process: grid generation, physics setup, simulation, and post-processing. The mass flow rate in each section of the zone 1 injection and sampling manifolds is also reported.

42 ENGINEERING↗

Mixed quantum/classical calculations of total and differential elastic and rotationally inelastic scattering cross sections for light and heavy reduced masses in a broad range of collision energies

The mixed quantum/classical theory (MQCT) for rotationally inelastic scattering developed recently [A. Semenov and D. Babikov, J. Chem. Phys. 139, 174108 (2013)] is benchmarked against the full quantum calculations for two molecular systems: He + H{sub 2} and Na + N{sub 2}. This allows testing new method in the cases of light and reasonably heavy reduced masses, for small and large rotational quanta, in a broad range of collision energies and rotational excitations. The resultant collision cross sections vary through ten-orders of magnitude range of values. Both inelastic and elastic channels are considered, as well as differential (over scattering angle) cross sections. In many cases results of the mixed quantum/classical method are hard to distinguish from the full quantum results. In less favorable cases (light masses, larger quanta, and small collision energies) some deviations are observed but, even in the worst cases, they are within 25% or so. The method is computationally cheap and particularly accurate at higher energies, heavier masses, and larger densities of states. At these conditions MQCT represents a useful alternative to the standard full-quantum scattering theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and Testing of a Labview- Controlled Catalytic Packed- Bed Reactor System For Production of Hydrocarbon Fuels

Gasified woody biomass (producer gas) was converted over a Mo/H+ZSM-5 catalyst to produce gasolinerange hydrocarbons. The effect of contaminants in the producer gas showed that key retardants in the system included ammonia and oxygen. The production of gasoline-range hydrocarbons derived from producer gas was studied and compared with gasoline-range hydrocarbon production from two control syngas mixes. Certain mole ratios of syngas mixes were introduced into the system to evaluate whether or not the heat created from the exothermic reaction could be properly controlled. Contaminant-free syngas was used to determine hydrocarbon production with similar mole values of the producer gas from the gasifier. Contaminant-free syngas was also used to test an ideal contaminant-free synthesis gas situation to mimic our particular downdraft gasifier. Producer gas was used in this study to determine the feasibility of using producer gas to create gasoline-range hydrocarbons on an industrial scale using a specific Mo/H+ZSM-5 catalyst. It was determined that after removing the ammonia, other contaminants poisoned the catalyst and retarded the hydrocarbon production process as well.

Gasification, Hydrocarbons, Mo/HZSM-5, Mo/H+ZSM-5,↗

Composition Variability Testing Using High Bounding LAW Melter Feed Simulant

This report documents the results of the testing that was performed to fulfill the Low Activity Waste (LAW) pretreated waste and melter feed product qualification requirements for Chemical Composition during Production as described in the Immobilized Low Activity Waste (ILAW) Product Compliance Plan and the Waste Treatment and Immobilization Plant (WTP) Contract. Meeting the product quality specifications relies on controlling the LAW melter feed preparation process and the resulting ILAW glass composition. In part, this control depends on the ability of the Melter Feed Preparation Vessel (MFPV) system to adequately mix the LAW melter feed after addition of the glass forming chemicals (GFCs), provide representative sampling of the vessel contents, measure the content level over the vessel operating range, and uniformly transfer the vessel contents. A series of tests were conducted on a 72.7% scaled down tank, 8 feet in diameter, which was used to represent the LAW MFPV. Prototypic equipment (such as radar level detectors, transfer pumps, agitators, and density probes) was installed in geometrically similar positions to that of the WTP tank. Other equipment, which is not fully prototypic, was also installed in the tank to fully represent the WTP tank equipment arrangement. In addition, a prototypic autosampler and a hydraulically similar transfer line were installed to represent the WTP tank sampling systems. Testing was performed using a simulant that represented the high bound of rheology for the LAW melter feed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-Situ Testing and Performance Assessment of a Redesigned WIPP Panel Closure - 13192

There are two primary regulatory requirements for Panel Closures at the Waste Isolation Pilot Plant (WIPP), the nation's only deep geologic repository for defense related Transuranic (TRU) and Mixed TRU waste. The Federal requirement is through 40 CFR 191 and 194, promulgated by the U.S. Environmental Protection Agency (EPA). The state requirement is regulated through the authority of the Secretary of the New Mexico Environment Department (NMED) under the New Mexico Hazardous Waste Act (HWA), New Mexico Statutes Annotated (NMSA) 1978, chap. 74-4-1 through 74-4-14, in accordance with the New Mexico Hazardous Waste Management Regulations (HWMR), 20.4.1 New Mexico Annotated Code (NMAC). The state regulations are implemented for the operational period of waste emplacement plus 30 years whereas the federal requirements are implemented from the operational period through 10,000 years. The 10,000 year federal requirement is related to the adequate representation of the panel closures in determining long-term performance of the repository. In Condition 1 of the Final Certification Rulemaking for 40 CFR Part 194, the EPA required a specific design for the panel closure system. The U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) has requested, through the Planned Change Request (PCR) process, that the EPA modify Condition 1 via its rulemaking process. The DOE has also requested, through the Permit Modification Request (PMR) process, that the NMED modify the approved panel closure system specified in Permit Attachment G1. The WIPP facility is carved out of a bedded salt formation 655 meters below the surface of southeast New Mexico. Condition 1 of the Final Certification Rulemaking specifies that the waste panels be closed using Option D which is a combination of a Salado mass concrete (SMC) monolith and an isolation/explosion block wall. The Option D design was also accepted as the panel closure of choice by the NMED. After twelve years of waste handling operations and a greater understanding of the waste and the behavior of the underground salt formation, the DOE has established a revised panel closure design. This revised design meets both the short-term NMED Permit requirements for the operational period, and also the Federal requirements for long-term repository performance. This new design is simpler, easier to construct and has less of an adverse impact on waste disposal operations than the originally approved Option D design. The Panel Closure Redesign is based on: (1) the results of in-situ constructability testing performed to determine run-of-mine salt reconsolidation parameters and how the characteristics of the bedded salt formation affect these parameters and, (2) the results of air flow analysis of the new design to determine that the limit for the migration of Volatile Organic Compounds (VOCs) will be met at the compliance point. Waste panel closures comprise a repository feature that has been represented in WIPP performance assessment (PA) since the original Compliance Certification Application of 1996. Panel closures are included in WIPP PA models principally because they are a part of the disposal system, not because they play a substantive role in inhibiting the release of radionuclides to the outside environment. The 1998 rulemaking that certified WIPP to receive transuranic waste placed conditions on the panel closure design to be implemented in the repository. The revised panel closure design, termed the Run-of-Mine (ROM) Panel Closure System (ROMPCS), is comprised of 30.48 meters of ROM salt with barriers at each end. The ROM salt is generated from ongoing mining operations at the WIPP and may be compacted and/or moistened as it is emplaced in a panel entry. The barriers consist of bulkheads, similar to those currently used in the panels as room closures. A WIPP performance assessment has been completed that incorporates the ROMPCS design into the representation of the repository, and compares repository performance to that achieved with the approved Option D design. Several key physical processes and rock mechanics principles are incorporated into the performance assessment. First, creep closure of the salt rock surrounding a panel entry results in consolidation of the ROM salt emplaced in the entry. Eventually, the ROM salt comprising the ROMPCS will approach a condition similar to intact salt. As the ROM salt reaches higher fractional densities during consolidation, back stress will be imposed on the surrounding rock mass leading to eventual healing of the disturbed rock zone above and below the panel closure. Healing of the disturbed rock zone above and below the ROMPCS reduces the porosity and permeability in those areas. Analysis of the new design demonstrates that: (1) the WIPP continues to meet regulatory compliance requirements when the ROMPCS design is implemented instead of Option D, and (2) there is no impact on the short-term effectiveness of the panel closure to limit the concentration of VOCs at the WIPP site boundary to a fraction of the health-based exposure limits (HBLs) during the operational period. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ISOLOK VALVE ACCEPTANCE TESTING FOR DWPF SME SAMPLING PROCESS

Evaluation of the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) cycle time identified several opportunities to improve the CPC processing time. Of the opportunities, a focus area related to optimizing the equipment and efficiency of the sample turnaround time for DWPF Analytical Laboratory was identified. The Mechanical Systems & Custom Equipment Development (MS&CED) Section of the Savannah River National Laboratory (SRNL) evaluated the possibility of using an Isolok{reg_sign} sampling valve as an alternative to the Hydragard{reg_sign} valve for taking process samples. Previous viability testing was conducted with favorable results using the Isolok sampler and reported in SRNL-STI-2010-00749 (1). This task has the potential to improve operability, reduce maintenance time and decrease CPC cycle time. This report summarizes the results from acceptance testing which was requested in Task Technical Request (TTR) HLW-DWPF-TTR-2010-0036 (2) and which was conducted as outlined in Task Technical and Quality Assurance Plan (TTQAP) SRNL-RP-2011-00145 (3). The Isolok to be tested is the same model which was tested, qualified, and installed in the Sludge Receipt Adjustment Tank (SRAT) sample system. RW-0333P QA requirements apply to this task. This task was to qualify the Isolok sampler for use in the DWPF Slurry Mix Evaporator (SME) sampling process. The Hydragard, which is the current baseline sampling method, was used for comparison to the Isolok sampling data. The Isolok sampler is an air powered grab sampler used to 'pull' a sample volume from a process line. The operation of the sampler is shown in Figure 1. The image on the left shows the Isolok's spool extended into the process line and the image on the right shows the sampler retracted and then dispensing the liquid into the sampling container. To determine tank homogeneity, a Coliwasa sampler was used to grab samples at a high and low location within the mixing tank. Data from the two locations were compared to determine if the contents of the tank were well mixed. The Coliwasa sampler is a tube with a stopper at the bottom and is designed to obtain grab samples from specific locations within the drum contents. A position paper (4) was issued to address the prototypic flow loop issues and simulant selections. A statistically designed plan (5) was issued to address the total number of samples each sampler needed to pull, to provide the random order in which samples were pulled and to group samples for elemental analysis. The TTR required that the Isolok sampler perform as well as the Hydragard sampler during these tests to ensure the acceptability of the Isolok sampler for use in the DWPF sampling cells. Procedure No.L9.4-5015 was used to document the sample parameters and process steps. Completed procedures are located in R&D Engineering job folder 23269.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Removal of Trace Amounts of Co-60 from NPP Waste Water Using UV-C Irradiation, TiO{sub 2} and Co-Treat Inorganic Ion Exchange Media - 16025

The removal of Co-60 from an aqueous nuclear liquid waste obtained from a BWR NPP was tested using a two-step process. In the first phase the liquid waste was oxidized with ultraviolet irradiation at 254 nm (UV-C irradiation) together with a photo-catalyst, TiO{sub 2} P25 AEROXIDE, to degrade the organic complexing agents present in the solution. During some of the experiments it was noticed that TiO{sub 2} P25 AEROXIDE also removed Co-60 from the solution. In the second phase the UV-C irradiated solution was mixed with inorganic ion exchange media, Co-Treat, to remove the rest of Co-60 from the solution. The effect of pH and contact time with UV-C irradiation were evaluated and both had a noticeable effect on the results. Best results were attained when pH of the initial test solution was lowered to 3.5 ± 0.2 before the UV-C irradiation. From the initial Co-60 activity, 2.2 Bq/ml, the activity decreased to 0.03 ± 0.01 Bq/ml after 24 hours of UV-C irradiation together with the photo-catalyst and mixing with Co-Treat. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗