Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Determination of peripheral underdosage at the lung-tumor interface using Monte Carlo radiation transport calculations

Prediction of dose distributions in close proximity to interfaces is difficult. In the context of radiotherapy of lung tumors, this may affect the minimum dose received by lesions and is particularly important when prescribing dose to covering isodoses. The objective of this work is to quantify underdosage in key regions around a hypothetical target using Monte Carlo dose calculation methods, and to develop a factor for clinical estimation of such underdosage. A systematic set of calculations are undertaken using 2 Monte Carlo radiation transport codes (EGSnrc and GEANT4). Discrepancies in dose are determined for a number of parameters, including beam energy, tumor size, field size, and distance from chest wall. Calculations were performed for 1-mm{sup 3} regions at proximal, distal, and lateral aspects of a spherical tumor, determined for a 6-MV and a 15-MV photon beam. The simulations indicate regions of tumor underdose at the tumor-lung interface. Results are presented as ratios of the dose at key peripheral regions to the dose at the center of the tumor, a point at which the treatment planning system (TPS) predicts the dose more reliably. Comparison with TPS data (pencil-beam convolution) indicates such underdosage would not have been predicted accurately in the clinic. We define a dose reduction factor (DRF) as the average of the dose in the periphery in the 6 cardinal directions divided by the central dose in the target, the mean of which is 0.97 and 0.95 for a 6-MV and 15-MV beam, respectively. The DRF can assist clinicians in the estimation of the magnitude of potential discrepancies between prescribed and delivered dose distributions as a function of tumor size and location. Calculation for a systematic set of 'generic' tumors allows application to many classes of patient case, and is particularly useful for interpreting clinical trial data.

61 RADIATION PROTECTION AND DOSIMETRY↗

ULTRAVIOLET RADIATIVE TRANSFER MODELING OF NEARBY GALAXIES WITH EXTRAPLANAR DUSTS

In order to examine their relation to the host galaxy, the extraplanar dusts of six nearby galaxies are modeled, employing a three-dimensional Monte Carlo radiative transfer code. The targets are from the highly inclined galaxies that show dust-scattered ultraviolet halos, and the archival Galaxy Evolution Explorer FUV band images were fitted with the model. The observed images are generally well-reproduced by two dust layers and one light source layer, whose vertical and radial distributions have exponential profiles. We obtained several important physical parameters, such as star formation rate (SFR{sub UV}), face-on optical depth, and scale-heights. Three galaxies (NGC 891, NGC 3628, and UGC 11794) show clear evidence for the existence of an extraplanar dust layer. However, it is found that the remaining three targets (IC 5249, NGC 24, and NGC 4173) do not necessarily need a thick dust disk to model the ultraviolet (UV) halo, because its contribution is too small and the UV halo may be caused by the wing part of the GALEX point spread function. This indicates that the galaxy samples reported to have UV halos may be contaminated by galaxies with negligible extraplanar (halo) dust. The galaxies showing evidence of an extraplanar dust layer fall within a narrow range on the scatter plots between physical parameters such as SFR{sub UV} and extraplanar dust mass. Several mechanisms that could possibly produce the extraplanar dust are discussed. We also found a hint that the extraplanar dust scale-height might not be much different from the polycyclic aromatic hydrocarbon emission characteristic height.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of a dry, mixed nuclear fuel storage array for nuclear criticality safety - 14339

A dry storage array of used nuclear fuel at the Idaho National Laboratory contains a mixture of more than twenty different types of research and test reactor fuels. Significant neutronic interaction occurs between fuel canisters within this large storage arrangement of 636 fuel storage canisters. Nuclear criticality safety is maintained primarily by moderation control and through control of neutron interaction and leakage provided by the credited geometry. Over the nearly forty years of operation the collected fuels are now arranged in a configuration that does not minimize the system neutron multiplication factor (k{sub eff}). This creates a concern since the entire remaining facility storage capacity cannot be utilized without exceeding the system minimum subcritical state (k{sub safe}) for ensuring nuclear criticality safety. This work determines a more optimal arrangement for the stored fuels with a goal to minimize the system k{sub eff}, but also with a minimum of potential fuel canister relocation movements. The ultimate goal is to establish a solution for this multiple-objective optimization problem by finding the Pareto Front for maximum k{sub eff} reduction versus the number of canister relocations. The process first required additional analysis of the array by Monte-Carlo neutron transport codes (specifically, MCNP) to gain a greater understanding of the interaction characteristics of the disparate fuel types. Some stored fuels are composed of primarily metallic and oxide components that provide very little inherent moderation, while other fuel types contain graphite or zirconium-hydride which can contribute a significant amount of moderation. These factors cause a complex relationship within a fuel arrangement with respect to thermal utilization and axial leakage probability. The new MCNP analysis was utilized to develop a simplified spreadsheet-based empirical model which simulates the array k{sub eff} result. This empirical model was benchmarked against additional MCNP calculations for various arrangements and then employed in the optimization analysis. A Tabu metaheuristic and stochastic approximation optimization was applied to the empirical model with the optimization function to minimize the array k{sub eff}. The optimization algorithm interrogated the empirical model to determine the optimal rearrangement for up to sixty canister movements. The Pareto Front was found, which shows that a limited number of canister relocation movements could allow the existing thirty-one empty array positions to be filled with common research reactor fuels while also yielding a reduction in the overall array k{sub eff} relative to the current arrangement. This will impart an improvement in the facility utilization while also offering an enhancement in the safety margin. The reduction in array reactivity has been confirmed by a final set of MCNP calculations with the proposed new arrangements. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dosimetry of a Small Air Cavity for Clinical Electron Beams: A Monte Carlo Study

This study investigated dosimetric changes in a water phantom when a small air cavity was presented at the central axis of a clinical electron beam. We used 6-, 9-, and 16-MeV electron beams with a 10 x 10 cm{sup 2} applicator and cutout produced by a Varian 21 EX linear accelerator. Percentage depth doses (PDDs) for different depths (0.5-7 cm), thicknesses (2-10 mm), and widths (1-5 cm) of air cavities were calculated using Monte Carlo simulations (EGSnrc code) validated by film measurements. By comparing PDDs of phantoms with and without the air cavity, it was found that when the depth or thickness of cavity was changed, the PDD curve below the cavity was shifted with a distance equal to the thickness of the cavity. However, when the width of the air cavity was changed, both the PDD curve and its slope within and below the cavity were changed. A larger width of the air cavity resulted in a shallower PDD curve within the cavity. The slope of the PDD curve below the cavity tended towards a value as the width of the air cavity was increased to 3-5 cm for the 6-, 9-, and 16-MeV electron beams. The dependence of the depth dose on the width of the air cavity is a result of the contribution of the electron side scattering in the water surrounding the cavity. The change in depth dose resulting from the presence of an air cavity can cause discrepancies between the calculated and actual dose during radiotherapy, unless the effects of the air cavity are properly characterized during treatment planning. From the dosimetry data in this study, neglecting an air cavity of 1-cm thickness in the build-up region of a 6-MeV electron beam resulted in a delivered dose 10-12% larger than the original prescription. Delivered doses 3% and 6% higher than the prescribed dose were observed when doses were prescribed at R{sub 80} for a 16-MeV electron beam. These results were obtained by neglecting air cavities with thicknesses equal to 2 and 4 mm, respectively, at a depth of 5 cm.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a Griffin model of the advanced test reactor

In the pursuit of a higher fidelity deterministic simulation capability of the Advanced Test Reactor, it is important to have a fast yet accurate deterministic neutronics model. Here, to achieve this, we employed an advanced two-step method. The first step involves generating homogenized cross sections using OpenMC, a cutting-edge Monte Carlo neutron transport code. OpenMC offers excellent modular capabilities, allowing for easy component integration and flexibility in incorporating new designs into the model. The second step involves deterministic transport calculations, which are performed using Griffin, a reactor physics application based on the Multiphysics Object-Oriented Simulation Environment (MOOSE). To ensure the accurate spatial resolution and assignment of material cross sections, a Cubit-generated mesh for the Advanced Test Reactor is utilized as an intermediate step between the OpenMC and Griffin models; Griffin utilizes the mesh for its finite element solution, while OpenMC material identifications are written to the mesh file to be used in Griffin material assignments. Additionally, a Python-based script converts the cross sections generated by OpenMC into the ISOXML format required by Griffin. Initial comparisons using the Griffin diffusion solver indicated good agreement between the neutron multiplication factors obtained from the standalone OpenMC model and the Griffin model, with differences of less than 10 pcm in the 2D geometry configuration; it was later determined that this agreement was likely due to compensating effect and was more likely on the order of –700 pcm relative to the OpenMC solution. However, in three-dimensional calculations, an unacceptably large error (almost 8,000 pcm) was found in the Griffin solution with the diffusion solver. Subsequent calculations using Griffin’s discrete ordinates solver demonstrated substantially improved agreement, within 116 pcm of the OpenMC solution used to generate the cross sections for Griffin. Building on this capability, future work will seek to perform more detailed validation calculations. The ultimate goal is to evaluate both transient and multiphysics simulations of the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PROTOPLANETARY DISK STRUCTURES IN OPHIUCHUS. II. EXTENSION TO FAINTER SOURCES

We present new results from a significant extension of our previous high angular resolution (0.''3 {approx} 40 AU) submillimeter array survey of the 340 GHz (880 {mu}m) thermal continuum emission from dusty circumstellar disks in the {approx}1 Myr old Ophiuchus star-forming region. An expanded sample is constructed to probe disk structures that emit significantly lower millimeter luminosities (hence dust masses), down to the median value for T Tauri stars. Using a Monte Carlo radiative transfer code, the millimeter visibilities and broadband spectral energy distribution for each disk are simultaneously reproduced with a two-dimensional parametric model for a viscous accretion disk that has a surface density profile {Sigma} {proportional_to} (R/R{sub c}){sup -}{gamma}exp [- (R/R{sub c}){sup 2-}{gamma}]. We find wide ranges of characteristic radii (R{sub c} = 14-198 AU) and disk masses (M{sub d} = 0.004-0.143 M{sub sun}), but a narrow distribution of surface density gradients ({gamma} = 0.4-1.1) that is consistent with a uniform value ({gamma}) = 0.9 {+-} 0.2 and independent of mass (or millimeter luminosity). In this sample, we find a correlation between the disk luminosity/mass and characteristic radius, such that fainter disks are both smaller and less massive. We suggest that this relationship is an imprint of the initial conditions inherited by the disks at their formation epoch, compare their angular momenta with those of molecular cloud cores, and speculate on how future observations can help constrain the distribution of viscous evolution timescales. No other correlations between disk and star properties are found. The inferred disk structures are briefly compared with theoretical models for giant planet formation, although resolution limitations do not permit us to directly comment on material inside R {approx} 20 AU. However, there is some compelling evidence for the evolution of dust in the planet formation region: 4/17 disks in the sample show resolved regions of significantly reduced millimeter optical depths within {approx}20-40 AU of their central stars.

79 ASTRONOMY AND ASTROPHYSICS↗

REVEALING THE STRUCTURE OF A PRE-TRANSITIONAL DISK: THE CASE OF THE HERBIG F STAR SAO 206462 (HD 135344B)

SAO 206462 (HD 135344B) has previously been identified as a Herbig F star with a circumstellar disk with a dip in its infrared excess near 10 {mu}m. In combination with a low accretion rate estimated from Br {gamma}, it may represent a gapped, but otherwise primordial or 'pre-transitional' disk. We test this hypothesis with Hubble Space Telescope coronagraphic imagery, FUV spectroscopy and imagery and archival X-ray data, and spectral energy distribution (SED) modeling constrained by the observed system inclination, disk outer radius, and outer disk radial surface brightness (SB) profile using the Whitney Monte Carlo Radiative Transfer Code. The essentially face-on (i {approx}< 20{sup 0}) disk is detected in scattered light from 0.''4 to 1.''15 (56-160 AU), with a steep (r {sup -9.6}) radial SB profile from 0.''6 to 0.''93. Fitting the SB data requires a concave upward or anti-flared outer disk, indicating substantial dust grain growth and settling by 8 {+-} 4 Myr. The warm dust component is significantly variable in near to mid-IR excess and in temperature. At its warmest, it appears confined to a narrow belt from 0.08 to 0.2 AU. The steep SED for this dust component is consistent with grains with a{<=} 2.5 {mu}m. For cosmic carbon to silicate dust composition, conspicuous 10 {mu}m silicate emission would be expected and is not observed. This may indicate an elevated carbon to silicate ratio for the warm dust, which is not required to fit the outer disk. At its coolest, the warm dust can be fit with a disk from 0.14 to 0.31 AU, but with a higher inclination than either the outer disk or the gaseous disk, providing confirmation of the high inclination inferred from mid-IR interferometry. In tandem, the compositional and inclination difference between the warm dust and the outer dust disk suggests that the warm dust may be of second-generation origin, rather than a remnant of a primordial disk component. With its near face-on inclination, SAO 206462's disk is a prime location for planet searches.

99 GENERAL AND MISCELLANEOUS↗

X-RAY IRRADIATED PROTOPLANETARY DISK ATMOSPHERES. II. PREDICTIONS FROM MODELS IN HYDROSTATIC EQUILIBRIUM

We present new models for the X-ray photoevaporation of circumstellar disks which suggest that the resulting mass loss (occurring mainly over the radial range 10-40 AU) may be the dominant dispersal mechanism for gas around low-mass pre-main-sequence stars, contrary to the conclusions of previous workers. Our models combine use of the MOCASSIN Monte Carlo radiative transfer code and a self-consistent solution of the hydrostatic structure of the irradiated disk. We estimate the resulting photoevaporation rates assuming sonic outflow at the surface where the gas temperature equals the local escape temperature and derive mass-loss rates of {approx}10{sup -9} M{sub sun} yr{sup -1}, typically a factor of 2-10 times lower than the corresponding rates in our previous work where we did not adjust the density structure of the irradiated disk. The somewhat lower rates, and the fact that mass loss is concentrated toward slightly smaller radii, result from the puffing up of the heated disk at a few AU which partially screens the disk at tens of AU. Our mass-loss fluxes agree with those of Alexander et al. but we differ from Alexander et al. in our assessment of the overall significance of X-ray photoevaporation, given the large disk radii (and hence emitting area) associated with X-ray-driven winds. Gorti and Hollenbach, on the other hand, predict considerably lower mass-loss fluxes than either Alexander et al. or ourselves and we discuss possible reasons for this difference. We highlight the fact that X-ray photoevaporation has two generic advantages for disk dispersal compared with photoevaporation by extreme ultraviolet (EUV) photons that are only modestly beyond the Lyman limit: the demonstrably large X-ray fluxes of young stars even after they have lost their disks and the fact that X-rays are effective at penetrating much larger columns of material close to the star. We however stress that our X-ray-driven mass-loss rates are considerably more uncertain than the corresponding rates for EUV photoevaporation (around 10{sup -10} M{sub sun} yr{sup -1}) and that this situation will need to be remedied through future radiation hydrodynamical simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Obtaining identical results with double precision global accuracy on different numbers of processors in parallel particle Monte Carlo simulations

We describe and compare different approaches for achieving numerical reproducibility in photon Monte Carlo simulations. Reproducibility is desirable for code verification, testing, and debugging. Parallelism creates a unique problem for achieving reproducibility in Monte Carlo simulations because it changes the order in which values are summed. This is a numerical problem because double precision arithmetic is not associative. Parallel Monte Carlo, both domain replicated and decomposed simulations, will run their particles in a different order during different runs of the same simulation because the non-reproducibility of communication between processors. In addition, runs of the same simulation using different domain decompositions will also result in particles being simulated in a different order. In [1], a way of eliminating non-associative accumulations using integer tallies was described. This approach successfully achieves reproducibility at the cost of lost accuracy by rounding double precision numbers to fewer significant digits. This integer approach, and other extended and reduced precision reproducibility techniques, are described and compared in this work. Increased precision alone is not enough to ensure reproducibility of photon Monte Carlo simulations. Non-arbitrary precision approaches require a varying degree of rounding to achieve reproducibility. For the problems investigated in this work double precision global accuracy was achievable by using 100 bits of precision or greater on all unordered sums which where subsequently rounded to double precision at the end of every time-step.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of array-type prompt gamma measurement system for in vivo range verification in proton therapy

Purpose: In vivo range verification is one of the most important parts of proton therapy to fully utilize its benefits delivering high radiation dose to tumor, while sparing the normal tissue with the so-called Bragg peak. Currently, however, range verification method is not used in clinics. The purpose of the present study is to optimize and evaluate the configuration of an array-type prompt gamma measurement system on determining distal dose edge for in vivo range verification of proton therapy. Methods: To effectively measure the prompt gammas against the background gammas, the Monte Carlo simulations with the MCNPX code were employed in optimizing the configuration of the measurement system, and the Monte Carlo method was also used to understand the effect of the background gammas, mainly neutron capture gammas, in the measured gamma distribution. To reduce the effect of the background gammas, the optimized energy window of 4-10 MeV in measuring the prompt gammas was employed. A parameterized source was used to maximize computation speed in the optimization study. A simplified test measurement system, using only one detector moving from one measurement location to the next, was constructed and applied to therapeutic proton beams of 80-220 MeV. For accurate determination of the distal dose edge, the sigmoidal curve-fitting method was applied to the measured distributions of the prompt gammas, and then, the location of the half-value between the maximum and minimum value in the curve-fitting was determined as the distal dose edge and compared with the beam range assessed by the proton dose distribution. Results: The parameterized source term employed in optimization process improved the calculation speed by up to {approx}300 times. The optimization study indicates that an array-type measurement system with 3, 2, 2, and 150 mm for scintillator thickness, slit width, septal thickness, and slit length, respectively, can effectively measure the prompt gamma distributions minimizing the contribution of background gammas. The present results show that a few hundred counts of prompt gammas can be easily obtained by measuring 10 s at each measurement location for proton beams of {approx}4 nA. The distal dose edges determined by the prompt gamma distribution are 5.45, 14.73, and 27.74 cm for proton beams of 5.17 (80 MeV), 14.99 (150 MeV), and 27.38 (220 MeV) cm, respectively. Conclusions: The results show that the array-type measurement system can measure prompt gamma distributions from a therapeutic proton beam within a short measurement time, and that the distal dose edge can be determined within a few millimeters of error without using any sophisticated analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

About the Impact of the Unresolved Resonance Region in Monte Carlo Simulations of Sodium Fast Reactors

In the last few years, and within the framework of different European projects, KENO-VI code from SCALE system has been employed to perform detailed continuous-energy Mon-te Carlo transport calculations for advanced fast reactors. The core characterization of both the sodium-cooled ASTRID and the lead-cooled ALFRED reactors was performed during the FP7 cross-cutting ESNII+ project; more recently, core calculations for the sodium-cooled Superphénix reactor and the improved European Sodium Fast Reactor design were performed within the HORIZON2020 ESFR-SMART project. In all cases, the effective multiplication factor predicted by KENO-VI was systematically higher (around 400-500 pcm) than the values computed by MCNP and Serpent Monte Carlo codes, using the same nu-clear data library.In order to provide insight into the origin of the observed discrepancies, a simplified 2D MOX-fueled SFR pin-cell benchmark has been launched. The multiplication factor, as well as 1-group and VITAMINJ 175-group cross-sections computed by KENO-VI, Serpent and MCNP codes employing ENDF/B-VII.1 data library, have been compared.Significant differences between KENO-VI and the other codes have been found in the un-resolved resonance regions of 239Pu and 241Pu capture and production cross sections, while negligible differences appeared outside those energy ranges. On the other hand, calculations without using probability tables have shown very good agreement. Quantita-tive comparison is presented and analyzed, along with a discussion of the impact of the probability-table treatment in the three codes for MOX-fueled systems with typical SFR spectrum.

Jimenez carrascosa, A↗

An angular biasing method using arbitrary convex polyhedra for Monte Carlo radiation transport calculations

This paper presents a new method for performing angular biasing in Monte Carlo radiation transport codes using arbitrary convex polyhedra to define regions of interest toward which to project particles (DXTRAN regions). The method is derived and is implemented using axis-aligned right parallelepipeds (AARPPs) and arbitrary convex polyhedra. Attention is also paid to possible numerical complications and areas for future refinement. A series of test problems are executed with void, purely absorbing, purely scattering, and 50% absorbing/50% scattering materials. For all test problems tally results using AARPP and polyhedral DXTRAN regions agree with analog and/or spherical DXTRAN results within statistical uncertainties. In cases with significant scattering the figure of merit (FOM) using AARPP or polyhedral DXTRAN regions is lower than with spherical regions despite the ability to closely fit the tally region. This is because spherical DXTRAN processing is computationally less expensive than AARPP or polyhedral DXTRAN processing. Thus, it is recommended that the speed of spherical regions be considered versus the ability to closely fit the tally region with an AARPP or arbitrary polyhedral region. It is also recommended that short calculations be made prior to final calculations to compare the FOM for the various DXTRAN geometries because of the influence of the scattering behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Criticality concerns of a group actinide co-crystallization separations approach to used nuclear fuel recycling

We report the co-crystallization of hexavalent actinides with uranyl nitrate hexahydrate has been established as a viable approach to achieving group actinide separation in used nuclear fuel recycle while avoiding the difficulties associated with the solvent-extraction process altogether. A preliminary neutronics safety analysis has been performed to alleviate criticality concerns associated with this group hexavalent actinide co-crystallization approach. The basic uranyl nitrate hexahydrate material compositions used are representative of used fuel found at commercial pressurized water reactors all around the U.S. This material is subsequently doped with various percentages of either typical reactor grade plutonium or with the total transuranic vector, replacing the uranium atoms in the crystal lattice structure. Infinite and effective neutron multiplication factors were calculated using the state-of-the-art Monte Carlo neutron transport code MCNP in a variety of plausible material configurations, assuming an acceptable safety limit for criticality to be an effective neutron multiplication factor less than 0.95. The results indicate that the crystal structures form a very subcritical intrinsic geometry even with six water molecules being incorporated into the crystal structure. In conclusion, the results of this research suggest that significant opportunity exists for the safe transfer of the group actinide separation approach from a laboratory to an operational scale.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of leakage neutron spectra for zirconium with D-T neutrons and validation of evaluated nuclear data

Integral neutronics experiments have been a powerful tool and method for examining the reliability of evaluated nuclear data. In the present paper, the accuracy of evaluated nuclear data for Zirconium has been validated by comparing measured leakage neutron spectra with calculated ones. Leakage neutron spectra from the irradiation of D-T neutrons on Zirconium samples were experimentally measured at 60° and 120° by using a time-of-flight method. Theoretical calculations are carried out by Monte Carlo neutron transport code MCNP-4C with evaluated nuclear data of the ENDF/B-VII.0, ENDF/B-VIII.0, JENDL-4.0 and CENDL-3.1 libraries. From the comparisons, it is found that the calculations with JENDL-4.0 gives better agreements with the experiments at 60° while a large discrepancies are observed in the 4–13.5 MeV energy range at 120°. However, the calculated spectra using the data from ENDF/B-VII.0, ENDF/B-VIII.0 and CENDL-3.1 libraries showed some discrepancies with the measured ones, especially caused by the difference of the elastic and inelastic angular distributions and the secondary neutron energy distributions in the continuum inelastic scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Subject-specific modeling framework for particle deposition using computational fluid dynamics

Quantifying particle deposition and dose in the respiratory tract requires a physiologically realistic representation and reproducible computational workflows. However, existing modeling frameworks, such as the International Commission on Radiological Protection (ICRP) compartmental models and the Multiple Path Particle Dosimetry (MPPD) tool, lack detailed deposition profiles and subject-specific capabilities. The combination of advances in computer vision algorithms applied to the respiratory tract and Computational Fluid and Particle Dynamics (CFPD) allows high-fidelity simulations of particle behavior in anatomically accurate geometries derived from individual CT scans. The segmentation, preprocessing, and file preparation task for a CFPD simulation was often time-consuming, and no prior studies to-date have yet presented a fully automated framework. This work presents a fully automated workflow to obtain individualized particle deposition profiles in the human respiratory tract. The pipeline starts with segmenting upper and lower airway geometries using morphological and deep learning-based methods, generating three-dimensional (3D) models from CT imaging data. Next, a series of algorithms are presented to quality check and prepare the 3D geometry for a CFD or CFPD simulation. The preprocessing step includes correcting geometric artifacts, enforcing a physically consistent mesh, and automatically identifying and capping multiple outlets, which is required for CFD/CFPD simulations. These processed models are then input into open-source (OpenFOAM) or commercial (StarCCM+) CFD solvers, where flow and transient particle transport equations — including turbulence and particle–wall interactions are solved under realistic breathing conditions. Finally, the resulting particle deposition profiles can be integrated with Monte Carlo radiation transport codes and state-of-the-art computational phantoms to assess organ-specific absorbed doses in scenarios of radioactive aerosol inhalation. The presented work streamlines respiratory tract segmentation, preprocessing for CFD/CFPD simulations, and integration with dose assessment workflows, reducing manual intervention and improving access to high-fidelity, subject-specific modeling. The high precision in predicted particle deposition and dose distributions can improve personalized treatment strategies in respiratory medicine and refine dose estimates for radiation protection.

AI↗

Excited State Electronic Properties of Sodium Iodide and Cesium Iodide

We compute from first principles the dielectric function, loss function, lifetime and scattering rate of quasiparticles due to electronic losses, and secondary particle spectrum due to plasmon decay in two scintillating alkali halides, sodium iodide and cesium iodide. Particular emphasis is placed on quasiparticles within several multiples of the band gap from the band edges. A theory for the decay spectra of plasmons and other electronic excitations in crystals is presented. Applications to Monte Carlo radiation transport codes are discussed.

Campbell, Luke W↗

Reconstruction of NSTX midplane neutral density profiles from visible imaging data

In this report the experimental determination of neutral densities in tokamak plasmas from line radiation is only accurate in the narrow region in which both the excitation rate and neutral density are significant. We describe an alternative procedure using the DEGAS 2 Monte Carlo neutral transport code to invert light emission data obtained from a tangentially viewing camera, yielding absolute radial profiles of deuterium atoms and molecules at midplane. That the neutral source in these simulations can be adequately characterized as a uniform flux at the vacuum vessel wall is demonstrated by the similarity of the shapes of the simulated and observed brightness profiles. A second test is obtained by comparing the resulting neutral pressures at the vessel walls with data from midplane micro-ion gauges. We also show that the simulated camera image is insensitive to variations in the spatial distribution of the neutral source.

(PSI-21) NSTX DEGAS↗

Surrogate modeling of Monte Carlo radiation transport with convolutional neural networks for shielding optimization

Here, we present a machine learning (ML)-based surrogate model using convolutional neural networks (CNN) designed to emulate the attenuation of neutron fields as they pass through various shielding materials. This model can compute the outgoing neutron flux almost instantaneously and achieves reasonable accuracy compared to traditional Monte Carlo (MC)-based codes, which are computationally intensive. This emulator alleviates the complexity of neutron radiation transport through shielding materials by reducing the dimensionality and enables shielding optimization for a known radiation environment. This optimization process, which would have taken an unrealistic timeline due to several complex radiation transport simulations, can now be achieved in minutes, thus increasing computational capabilities in radiation shielding assessment. We demonstrate the applications of this emulator in computing effective dose rates and optimizing shielding solutions for a heavy-ion accelerator facility, such as the Facility for Rare Isotope Beams, where secondary neutrons produced via beam interactions dominate the radiation environment.

accelerator shielding↗