At least 1,531 records · Page 85

Capacity Payments in Restructured Markets under Low and High Penetration Levels of Renewable Energy

There is considerable debate about the degree to which restructured markets perform successfully in their use of capacity markets. In providing appropriate incentives for new and existing generation to meet reliability requirements, a variety of capacity market designs have developed across RTOs and ISOs in the United States and internationally. Growing levels of variable renewable energy (VRE) resources arguably create new challenges for capacity market designs, because VREs suppress energy prices while providing relatively little capacity, with these effects increase with VRE penetration. The purpose of this report is threefold. First, we provide a brief outline of the purpose and design of various capacity markets under consideration using variable resource requirement (VRR) demand curves. Second, we discuss some of the main challenges raised in existing literature and a set of interviews that we conducted with market participants, regulators, and observers, including where there substantive differences in opinion. Third, we consider some of the challenges that may be specific to higher penetration levels of VRE. While the well known 'merit order' effect from VRE can be expected to suppress wholesale energy prices and revenue, this may be partly mitigated by increased capacity payments and the greater importance of AS payments for flexible capacity. The potential for greater reliance on capacity markets for generator revenues may amplify any inefficiency and costs associated with capacity price volatility and other suboptimal market design choices. Regulatory intervention to ensure adequate capacity payments and ancillary service revenue may become more prevalent under current market designs as the timescale for market signals shifts increasingly from near term (e.g., day-ahead in wholesale electricity markets) to longer term (annual intervals in capacity markets). Our review and discussion with market participants suggest substantive challenges may remain in implementing capacity markets that provide both adequate operational and investment incentives, particularly under high-VRE scenarios with greater need for flexible capacity.

14 SOLAR ENERGY↗

Ultrasensitive Label-free Electronic Chip for DNA Analysis Using Carbon Nanotube Nanoelectrode Arrays

There is a strong need for faster, cheaper, and simpler methods for nucleic acid analysis in today s clinical tests. Nanotechnologies can potentially provide solutions to these requirements by integrating nanomaterials with biofunctionalities. Dramatic improvement in the sensitivity and multiplexing can be achieved through the high-degree miniaturization. Here, we present our study in the development of an ultrasensitive label-free electronic chip for DNA/RNA analysis based on carbon nanotube nanoelectrode arrays. A reliable nanoelectrode array based on vertically aligned multi-walled carbon nanotubes (MWNTs) embedded in a SiO2 matrix is fabricated using a bottom-up approach. Characteristic nanoelectrode behavior is observed with a low-density MWNT nanoelectrode array in measuring both the bulk and surface immobilized redox species. The open-end of MWNTs are found to present similar properties as graphite edge-plane electrodes, with a wide potential window, flexible chemical functionalities, and good biocompatibility. A BRCA1 related oligonucleotide probe with 18 bases is covalently functionalized at the open ends of the MWNTs and specifically hybridized with an oligonucleotide target as well as a PCR amplicon. The guanine bases in the target molecules are employed as the signal moieties for the electrochemical measurements. Ru(bpy)3(2+) mediator is used to further amplify the guanine oxidation signal. This technique has been employed for direct electrochemical detection of label-free PCR amplicon through specific hybridization with the BRCAl probe. The detection limit is estimated to be less than approximately 1000 DNA molecules, approaching the limit of the sensitivity by laser-based fluorescence techniques in DNA microarray. This system provides a general electronic platform for rapid molecular diagnostics in applications requiring ultrahigh sensitivity, high-degree of miniaturization, simple sample preparation, and low- cost operation.

Li, Jun↗

PRECISE BLACK HOLE MASSES FROM MEGAMASER DISKS: BLACK HOLE-BULGE RELATIONS AT LOW MASS

The black hole (BH)-bulge correlations have greatly influenced the last decade of efforts to understand galaxy evolution. Current knowledge of these correlations is limited predominantly to high BH masses (M{sub BH{approx}}>10{sup 8} M{sub sun}) that can be measured using direct stellar, gas, and maser kinematics. These objects, however, do not represent the demographics of more typical L < L* galaxies. This study transcends prior limitations to probe BHs that are an order of magnitude lower in mass, using BH mass measurements derived from the dynamics of H{sub 2}O megamasers in circumnuclear disks. The masers trace the Keplerian rotation of circumnuclear molecular disks starting at radii of a few tenths of a pc from the central BH. Modeling of the rotation curves, presented by Kuo et al., yields BH masses with exquisite precision. We present stellar velocity dispersion measurements for a sample of nine megamaser disk galaxies based on long-slit observations using the B and C spectrograph on the Dupont telescope and the Dual Imaging Spectrograph on the 3.5 m telescope at Apache Point. We also perform bulge-to-disk decomposition of a subset of five of these galaxies with Sloan Digital Sky Survey imaging. The maser galaxies as a group fall below the M{sub BH}-{sigma}{sub *} relation defined by elliptical galaxies. We show, now with very precise BH mass measurements, that the low-scatter power-law relation between M{sub BH} and {sigma}{sub *} seen in elliptical galaxies is not universal. The elliptical galaxy M{sub BH}-{sigma}{sub *} relation cannot be used to derive the BH mass function at low mass or the zero point for active BH masses. The processes (perhaps BH self-regulation or minor merging) that operate at higher mass have not effectively established an M{sub BH}-{sigma}{sub *} relation in this low-mass regime.

79 ASTRONOMY AND ASTROPHYSICS↗

Tunable Metasurface External-Cavity Quantum Cascade Lasers up to 5.74 THz

Vertical-external-cavity surface-emitting lasers based on amplifying quantum-cascade metasurfaces are demonstrated in the 5–6 THz range for the first time. Enhanced parasitic coupling to lossy surface modes requires updated design guidelines, while elevated losses and lower available material gain limit the scaling of the metasurface period from previous designs. A series of metasurface devices with varying periods employing both uniform and focusing metasurfaces is fabricated and characterized. Reducing the metasurface period below 70% of the free-space wavelength enables devices with superior performance, achieving pulsed operation up to 5.74 THz with peak output powers of 1.3 mW, maximum operating temperatures up to 83 K, and continuous-wave operation up to 54 K with 23 μW of output power. In the best case, single-mode tuning from 5.23–5.73 THz, which corresponds to a 9.1% fractional tuning, is realized with near-Gaussian far-field profiles maintained across the entire range. Finally, these results establish quantum cascade vertical-external-cavity surface-emitting lasers as promising candidates for high-frequency local oscillator applications in heterodyne spectroscopy.

gallium arsenide↗

A monolithic Si bolometer array for the Caltech Submillimeter Observatory

We are developing a submillimeter continuum camera for the Caltech Submillimeter Observatory (CSO) located on Mauna Kea. The camera will employ a monolithic Si bolometer array which was developed by Moseley et al. at the NASA Goddard Space Flight Center (GSFC). The camera will be cooled to a temperature of about 300 mK in a He-3 cryostat, and will operate primarily at wavelengths of 350 and 450 micrometers. We plan to use a bolometer array with 1x24 directly illuminated pixels, each pixel of dimension 1x2 sq mm, which is about half of the F/4 beam size at these wavelengths. Each pixel is 10 to 12 micrometers thick and is supported only by four thin Si legs formed by wet chemical etch. The pixels are doped n-type by phosphorus implantation, compensated by boron implantation. Signals from the bolometer pixels are first amplified by cryogenically cooled FET's. The signals are further amplified by room-temperature amplifiers and then separately digitized by 16 bit A/D converters with differential inputs. The outputs of the A/D converters are fed into a digital signal processing board via fiber-optic cables. The electronics and data acquisition system were designed by the Goddard group. We will report the status of this effort.

Wang, Ning↗

Ultra low-noise charge coupled device

Special purpose CCD designed for ultra low-noise imaging and spectroscopy applications that require subelectron read noise floors, wherein a non-destructive output circuit operating near its 1/f noise regime is clocked in a special manner to read a single pixel multiple times. Off-chip electronics average the multiple values, reducing the random noise by the square-root of the number of samples taken. Noise floors below 0.5 electrons rms are possible in this manner. In a preferred embodiment of the invention, a three-phase CCD horizontal register is used to bring a pixel charge packet to an input gate adjacent a floating gate amplifier. The charge is then repeatedly clocked back and forth between the input gate and the floating gate. Each time the charge is injected into the potential well of the floating gate, it is sensed non-destructively. The floating gate amplifier is provided with a reference voltage of a fixed value and a pre-charge gate for resetting the amplifier between charge samples to a constant gain. After the charge is repeatedly sampled a selected number of times, it is transferred by means of output gates, back into the horizontal register, where it is clocked in a conventional manner to a diffusion MOSFET amplifier. It can then be either sampled (destructively) one more time or otherwise discarded.

Janesick, James R.↗

Numerical simulation of particle-wave interaction in boundary layers

The effects of wall injection and particle motion on the spatial stability of two-dimensional plane channel flow are investigated. For this purpose, an accurate Navier-Stokes solver to simulate the space-time evolution of disturbances in three-dimensional flows has been developed. The code is operational on the NASA Langley CRAY2 and can be ported to any other supercomputer. The code has been tested extensively in tracking the spatial evolution of two-dimensional disturbances in plane channel flow and provided excellent agreement with the linear theory including at the inflow/outflow boundaries. Preliminary calculations have been performed to investigate the effects of stationary and moving sources of vortical disturbances simulating a particle traveling in the flow field. Results suggest that even at very low amplitudes, vortical disturbances act as amplifiers on the Tollmien-Schlichting waves promoting rapid instability. It is also found that slow moving particles are more dangerous than both stationary and fast moving particles for the same disturbance levels.

Biringen, S.↗

Synthesis of Submillimeter Radiation for Spectroscopy

The frequency-multiplier submillimeter spectrometer (FMSS) is a laboratory apparatus for far-infrared molecular spectroscopy, embodying several advances over prior such apparatuses. The most innovative part of the FMSS is a source of monochromatic submillimeter- wavelength radiation that can be tuned over a wide frequency range, as needed for trace gas analyses and molecular- structure studies for which such apparatuses are typically used. The radiation source features a modular design and is built mostly from commercially available components. It includes a computer-controlled radio-frequency synthesizer, amplifiers, and frequency multipliers of a type heretofore used in local oscillators for heterodyne far-infrared receivers. In conjunction with the rest of the apparatus, this source makes it possible to perform measurements over large portions of the submillimeter-wavelength spectrum with resolution, accuracy, and sensitivity greater than those achievable in Fourier-transform infrared spectroscopy. In comparison with prior laboratory submillimeter- wavelength radiation sources, this source is much lighter in weight, less cumbersome, less power-hungry, and capable of sustained operation with less intervention by laboratory personnel. Also, unlike some prior submillimeter-wavelength sources, this source does not require a high-voltage power source. As shown in more detail in the figure, the radiation source includes a sweep frequency synthesizer connected to an external waveform generator, the output of which is used as a reference signal. The synthesizer is computer-controlled through a standard general-purpose interface bus (GPIB) and is operated in phase-locked continuous- wave mode for all measurements. The synthesizer output ranges in frequency from 11 to 18 GHz. For suppression of frequency spurs and harmonics, the output of the frequency synthesizer is fed through a tunable yttrium iron garnet (YIG) filter, which is swept in frequency simultaneously with the frequency synthesizer.

Maiwald, Frank↗

Electron gun simulation for 95 GHz gyrotron

A triode type Magnetron Injection Gun (MIG) for a 2 MW, 95 GHz Gyrotron has been designed by using commercially available code EGUN and another in-house developed code MIGANS. The operating mode of the gyrotron is TE{sub 24.8} and it is operated in the fundamental harmonic. The operating voltages of the modulating anode and the accelerating anode are 61 kV and 85 kV respectively. The parametric dependences of modulating anode voltage and cathode magnetic field on the beam quality have also been studied. (author)

43 PARTICLE ACCELERATORS↗

Logic operations with active topological defects

Logic operations performed by semiconductor-based transistors are the basis of modern computing. There is considerable interest in creating autonomous materials systems endowed with the capability to make decisions. In this work, we introduce the concept of using topological defects in active matter to perform logic operations. When an extensile active stress in a nematic liquid crystal is turned on, +1/2 defects can self-propel, in analogy to electron transport under a voltage gradient. By relying on hydrodynamic simulations of active nematics, we demonstrate that patterns of activity, when combined with surfaces imparting certain orientations, can be used to control the formation and transport of +1/2 defects. We further show that asymmetric high- and low-activity patterns can be used to create effective defect gates, tunnels, and amplifiers. The proposed active systems offer the potential to perform computations and transmit information in active soft materials, including actin-, tubulin-, and cell-based systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrasonic Leak Detection System

A system for detecting ultrasonic vibrations. such as those generated by a small leak in a pressurized container. vessel. pipe. or the like. comprises an ultrasonic transducer assembly and a processing circuit for converting transducer signals into an audio frequency range signal. The audio frequency range signal can be used to drive a pair of headphones worn by an operator. A diode rectifier based mixing circuit provides a simple, inexpensive way to mix the transducer signal with a square wave signal generated by an oscillator, and thereby generate the audio frequency signal. The sensitivity of the system is greatly increased through proper selection and matching of the system components. and the use of noise rejection filters and elements. In addition, a parabolic collecting horn is preferably employed which is mounted on the transducer assembly housing. The collecting horn increases sensitivity of the system by amplifying the received signals. and provides directionality which facilitates easier location of an ultrasonic vibration source.

Youngquist, Robert C.↗

NASA Tech Briefs, February 2003

opics covered include: Integrated Electrode Arrays for Neuro-Prosthetic Implants; Eroding Potentiometers; Common/Dependent-Pressure-Vessel Nickel-Hydrogen Batteries; 120-GHz HEMT Oscillator With Surface-Wave-Assisted Antenna; 80-GHz MMIC HEMT Voltage-Controlled Oscillator; High-Energy-Density Capacitors; Microscale Thermal-Transpiration Gas Pump; Instrument for Measuring Temperature of Water; Improved Measurement of Coherence in Presence of Instrument Noise; Compact Instruments Measure Helium-Leak Rates; Irreversible Entropy Production in Two-Phase Mixing Layers; Subsonic and Supersonic Effects in Bose-Einstein Condensate; Nanolaminate Mirrors With "Piston" Figure-Control Actuators; Mixed Conducting Electrodes for Better AMTEC Cells; Process for Encapsulating Protein Crystals; Lightweight, Self-Deployable Wheels; Grease-Resistant O Rings for Joints in Solid Rocket Motors; LabVIEW Serial Driver Software for an Electronic Load; Software Computes Tape-Casting Parameters; Software for Tracking Costs of Mars Projects; Software for Replicating Data Between X.500 and LDAP Directories; The Technical Work Plan Tracking Tool; Improved Multiple-DOF SAW Piezoelectric Motors; Propulsion Flight-Test Fixture; Mechanical Amplifier for a Piezoelectric Transducer; Swell Sleeves for Testing Explosive Devices; Linear Back-Drive Differentials; Miniature Inchworm Actuators Fabricated by Use of LIGA; Using ERF Devices to Control Deployments of Space Structures; High-Temperature Switched-Reluctance Electric Motor; System for Centering a Turbofan in a Nacelle During Tests; Fabricating Composite-Material Structures Containing SMA Ribbons; Optimal Feedback Control of Thermal Networks; Artifacts for Calibration of Submicron Width Measurements; Navigating a Mobile Robot Across Terrain Using Fuzzy Logic; Designing Facilities for Collaborative Operations; and Quantitating Iron in Serum Ferritin by Use of ICP-MS.

Source record↗

High-Altitude MMIC Sounding Radiometer for the Global Hawk Unmanned Aerial Vehicle

Microwave imaging radiometers operating in the 50-183 GHz range for retrieving atmospheric temperature and water vapor profiles from airborne platforms have been limited in the spatial scales of atmospheric structures that are resolved not because of antenna aperture size, but because of high receiver noise masking the small variations that occur on small spatial scales. Atmospheric variability on short spatial and temporal scales (second/ km scale) is completely unresolved by existing microwave profilers. The solution was to integrate JPL-designed, high-frequency, low-noise-amplifier (LNA) technology into the High-Altitude MMIC Sounding Radiometer (HAMSR), which is an airborne microwave sounding radiometer, to lower the system noise by an order of magnitude to enable the instrument to resolve atmospheric variability on small spatial and temporal scales. HAMSR has eight sounding channels near the 60-GHz oxygen line complex, ten channels near the 118.75-GHz oxygen line, and seven channels near the 183.31-GHz water vapor line. The HAMSR receiver system consists of three heterodyne spectrometers covering the three bands. The antenna system consists of two back-to-back reflectors that rotate together at a programmable scan rate via a stepper motor. A single full rotation includes the swath below the aircraft followed by observations of ambient (roughly 0 C in flight) and heated (70 C) blackbody calibration targets located at the top of the rotation. A field-programmable gate array (FPGA) is used to read the digitized radiometer counts and receive the reflector position from the scan motor encoder, which are then sent to a microprocessor and packed into data files. The microprocessor additionally reads telemetry data from 40 onboard housekeeping channels (containing instrument temperatures), and receives packets from an onboard navigation unit, which provides GPS time and position as well as independent attitude information (e.g., heading, roll, pitch, and yaw). The raw data files are accessed through an Ethernet port. The HAMSR data rate is relatively low at 75 kbps, allowing for real-time access over the Global Hawk high-data-rate downlink. Once on the ground, the raw data are unpacked and processed through two levels of processing. The Level 1 product contains geo-located, time-stamped, calibrated brightness temperatures for the Earth scan. These data are then input to a lD variational retrieval algorithm to produce temperature, water vapor, and cloud liquid water profiles, as well as several derived products such as potential temperature and relative humidity.

Brown, Shannon T.↗

Thermal effects in an ultrafast BiB 3 O 6 optical parametric oscillator at high average powers

An ultrafast, high-average-power, extended-cavity, femtosecond BiB 3 O 6 optical parametric oscillator was constructed as a test bed for investigating the scalability of infrared parametric devices. Despite the high pulse energies achieved by this system, the reduction in slope efficiency near the maximum-available pump power prompted the investigation of thermal effects in the crystal during operation. Furthermore, the local heating effects in the crystal were used to determine the impact on both phase matching and thermal lensing to understand limitations that must be overcome to achieve microjoule-level pulse energies at high repetition rates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two‐Color Amplified Spontaneous Emission from Auger‐Suppressed Quantum Dots in Liquids

Abstract Colloidal quantum‐dot (QD) lasing is normally achieved in close‐packed solid‐state films, as a high QD volume fraction is required for stimulated emission to outcompete fast Auger decay of optical‐gain‐active multiexciton states. Here a new type of liquid optical‐gain medium is demonstrated, in which compact compositionally‐graded QDs (ccg‐QDs) that feature strong suppression of Auger decay are liquefied using a small amount of solvent. Transient absorption measurements of ccg‐QD liquid suspensions reveal broad‐band optical gain spanning a wide spectral range from 560 (green) to 675 nm (red). The gain magnitude is sufficient to realize a two‐color amplified spontaneous emission (ASE) at 637 and 594 nm due to the band‐edge (1S) and the excited‐state (1P) transition, respectively. Importantly, the ASE regime is achieved using quasicontinuous excitation with nanosecond pulses. Furthermore, the ASE is highly stable under prolonged excitation, which stands in contrast to traditional dyes that exhibit strong degradation under identical excitation conditions. These observations point toward a considerable potential of high‐density ccg‐QD suspensions as liquid, dye‐like optical gain media that feature readily achievable spectral tunability and stable operation under intense photoexcitation.

Li, Xueyang↗

First Measurements and Results With a Stretched Wire Test Setup

The LINAC Coherent Light Source [LCLS] is a free electron laser, designed to produce high brilliant X-ray beams using Self Amplified Spontaneous Emission [SASE]. Due to the physics of SASE, the electron beam has to be held very precisely on the same trajectory as the X-ray light beam generated by the undulator magnets. To optimize the SASE output, trajectory deviations between both beams have to be minimized to a few micrometers along the entire undulator section and held stable over the time period between beam-based-alignment processes. Consequently, extremely high position stability of all magnets in the undulator section is required to operate the LCLS successfully. The knowledge of any magnet movement exceeding few micrometers during periods of several weeks is essential for efficient X-ray generation. A well known principle of monitoring transverse component positions along beam lines is the application of stretched wires, associated with suitable wire position sensors and electronics. The particular challenge at LCLS is the required wire system performance in conjunction with the length of the undulator section and the large number of monitors. Verification of system stability and resolution under real conditions is the primary goal of this test setup. A stretched wire test setup has been implemented to gain experience for the final design of a wire system, which will meet the position monitoring requirements in the LCLS undulator section. The report briefly introduces the system's architecture and describes first measurements and results.

43 PARTICLE ACCELERATORS↗

Masers for the telstar satellite communications experiment

This paper discusses the design and characteristics of ruby traveling-wave masers operating at 4 gc. These masers, characterized by an average gain of ≈35 db over a bandwidth of 25 mc, are equipped with waveguide input transmission lines, rather than the previously employed coaxial cables. This change results in an over-all noise temperature of 3.5°K for these devices, rather than the 10°K exhibited by earlier masers. The maser noise temperature now closely approximates sky temperatures, which set the ultimate limit on earthbound receiver sensitivity. The improvements to be had by further reduction in amplifier noise are therefore almost negligible. A less well known maser property, i.e., its freedom from distortion, even when driven well into gain saturation, is discussed.

TELSTAR SATELLITE↗

Multi-scale variation in spatial heterogeneity for microbial community structure in an eastern Virginia agricultural field

To better understand the distribution of soil microbial communities at multiple spatial scales, a survey was conducted to examine the spatial organization of community structure in a wheat field in eastern Virginia (USA). Nearly 200 soil samples were collected at a variety of separation distances ranging from 2.5 cm to 11 m. Whole-community DNA was extracted from each sample, and community structure was compared using amplified fragment length polymorphism (AFLP) DNA fingerprinting. Relative similarity was calculated between each pair of samples and compared using geostatistical variogram analysis to study autocorrelation as a function of separation distance. Spatial autocorrelation was found at scales ranging from 30 cm to more than 6 m, depending on the sampling extent considered. In some locations, up to four different correlation length scales were detected. The presence of nested scales of variability suggests that the environmental factors regulating the development of the communities in this soil may operate at different scales. Kriging was used to generate maps of the spatial organization of communities across the plot, and the results demonstrated that bacterial distributions can be highly structured, even within a habitat that appears relatively homogeneous at the plot and field scale. Different subsets of the microbial community were distributed differently across the plot, and this is thought to be due to the variable response of individual populations to spatial heterogeneity associated with soil properties. c2003 Federation of European Microbiological Societies. Published by Elsevier Science B.V. All rights reserved.