Search NASA⌕ Search

SEARCH · Search NASA

Results for “Paper”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Development of a series of Korean pediatric and adult head computational phantoms and application to nuclear medicine dosimetry - Paper 26

Over the past decades, advances in Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) imaging techniques and an increasing number of new radiopharmaceuticals have resulted in a surge of neuroimaging applications in nuclear medicine on pediatric and adult patients. It is not feasible to directly measure the absorbed dose to the organs of the human body from nuclear medicine procedures. The formalism of the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine has been adopted as the calculation method to estimate radiation dose to target organs from radionuclides distributed in source organs. The absorbed dose to a target organ from different types of radionuclides distributed within source organs can be estimated by the products of the time-integrated activity in each source region and organ dose conversion coefficients, called S values (Gy/MBq-s). S values are computed from a comprehensive set of Specific Absorbed Fraction (SAF), which are calculated from computational human phantoms with realistic anatomical structures coupled with Monte Carlo transport technique. The current SAF data for pediatric and adult head and brain dosimetry is based on a series of stylized computational phantoms. However, dosimetric errors caused by the unrealistic anatomy of stylized phantoms in internal dosimetry calculations have been reported by several studies. In the current study, we developed a series of realistic computational head phantoms representing 6, 9, 12, 15, and 22-year-old standard Korean males, and computed a comprehensive set of SAFs using the phantoms coupled with Monte Carlo transport technique. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparing the Predicted Neutron Yields and Radioactivities of Two Accelerators in Taiwan: 235-MeV Proton Cyclotron and 3-GeV Electron Synchrotron - Paper 27

Two major accelerator facilities in Taiwan are about to open. The first proton treatment center equipped with a 235 MeV proton cyclotron and four gantry rooms in Linkou Chang Gung Memorial Hospital is currently under beam commissioning and clinical trials are expected to start soon. In addition, the second light source facility, named Taiwan Photon Source (TPS), in National Synchrotron Radiation Research Center is now approaching its final assembly and will be ready for beam commissioning in this year. These two facilities mark significant milestones in accelerator development and application of Taiwan. Operation of these accelerators could potentially produce intense secondary neutrons and serious material activation. Both issues are crucial and must be carefully evaluated for the purpose of radiation safety, especially in a densely populated hospital or in a crowded user experimental floor. Monte Carlo simulations with evaluated cross sections or benchmarked nuclear models are considered as the most reliable method for accelerator shielding designs or related analyses. This study predicted and compared the magnitudes of potential neutron production and induced radioactivity due to the operation of these two accelerators. For conservative consideration, the primary particle energy and full beam output were assumed to hit a thick target for maximum radiation production. In order to ensure the quality of predictions, much effort has been devoted to associated benchmark calculations, targeting those bombardment experiments involving with the same particle types and similar beam energies and targets. (authors)

43 PARTICLE ACCELERATORS↗

Comparing Measured (a,n) Thick Target Yields to MCNP6 using TENDL 2012 Libraries - Paper 31

MCNP6, due to the heritage of MCNPX, has always possessed the capability to transport the light ions, such as alpha particles. Two types of competing physics take place during the particle transport: atomic and nuclear physics. Charged particles lose energy to media due to Coulombic interactions. MCNP6 models Coulombic interactions through the use of the continuous slowing down approximation. Stopping powers are calculated at a variety of energies using the Bethe-Bloch formula with Sternheimer and Peierls density effect correction. For energies less than 1.31 MeV/AMU, a low-energy SPAR model is used. When the energy of the particle is high enough, there is a transition from nuclear interactions to nucleon interactions. MCNP6 possess various physics models to account for these types of intra-nuclear cascades. These models are less accurate at low energies. Even though MCNP6 will transport these light ions to low energies (i.e. less than 20 MeV), most of the available model physics in MCNP6, for nuclear interactions, has a suggested minimum energy of ∼20-200 MeV. The result of the poorer prediction at low energies causes important light ion events, such as F-19(a,n)Na-22 from U-234 decay in UF{sub 6}, to produce orders of magnitude fewer neutrons in MCNP6 than should be emitted. As with neutrons, ACE (A Compact ENDF) formatted light ion libraries have been developed from several different evaluations. These libraries possess better physics at low energies where the physics models break down. The TENDL 2012 evaluations possess alpha transport libraries, in ACE format, such that they can easily be used with codes like MCNP6 that read ACE formatted cross sections. As a result, a capability was developed for MCNP6 to read and implement these library cross sections when the light ion reached energies below the library upper energy cutoff. Perfectly modelling an experiment for benchmark comparisons to a code calculation can be tricky. For complex setups, systematic error is always possible; and usually a hefty uncertainty analysis is required to quantify just the geometry setup and material combination choices. For an (a,n) interaction, a thick target yield is defined as the amount of neutrons emitted given that the alpha ranges out in the material. For alpha transport at low energy <10 MeV, in reasonably dense materials (>1-2 g/cc), with a material dimension length larger than a few hundred microns, alpha particles will tend to completely stop and range out in the material. For Li, Be, B, C, N, O, F, Na, Mg and Al thick target yields exist in 200 keV intervals from 1 to 9.8 MeV (most of the elements do have (a,n) thresholds above 1 MeV). Because modelling a thick target yield in MCNP6 is much easier than attempting to account for the complexity of systematic error from a full out experiment, we present here comparisons of (a,n) thick target yields to those calculated in MCNP6 using the TENDL 2012 alpha library evaluations.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Preliminary Verification of the 2-D Transport Module of Radiation Shielding Code ARES - Paper 33

ARES is a multi-group SN particle transport code system with arbitrary order anisotropic scattering. It is primarily used for the nuclear systems' shielding calculation and analysis in the case of one dimensional, two dimensional and three dimensional systems. ARES2D is the 2-D transport module of ARES code system. It is used to solve the first-order form of the steady-state Boltzmann transport equation in the two dimensional geometry with uniform rectangular mesh. The equation's energy dependence is modeled using multiple energy groups. The angular dependence is modeled using discrete ordinates method. The spatial variable is modeled using finite differencing scheme. The overall solution technique is source iteration with Partial Current Rebalance acceleration of the scattering source. ARES2D is capable of calculating k eigenvalue and fixed source problem with arbitrary order anisotropic scattering in two dimensional geometry. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of ADVANTG Simulations to Simple Shielding Measurements - Paper 36

Monte Carlo (MC) radiation transport simulations, like those performed using Monte Carlo N-Particle (MCNP), can be highly accurate but require time to reduce the statistical uncertainties in the calculated detector response(s). Many different 'variance reduction' techniques devised over the years increase the efficiency of MC calculations, but these methods can be more art than science. Many of these methods are problem specific or require careful tuning of parameters for good performance. One of the best variance reduction methods, in terms of both reliable performance increases and ease of use, is the use of weight windows. Weight windows are derived from an importance map in space and energy that allows the transport code to focus more simulation time on particles that have a higher likelihood of being important to the final detector response. Less time is spent simulating particles that have little chance of making a contribution to the detector response. MCNP already includes the abilities to generate and use weight windows. Unfortunately, generating weight windows can take a very long time, perhaps longer than the original problem. Oak Ridge National Laboratory has led the development of hybrid methods using a discrete ordinates adjoint calculation to quickly develop an importance map (weight windows) for use in a Monte Carlo code. The Consistent Adjoint Driven Importance Sampling (CADIS) method uses an adjoint calculation to develop both an importance map and a biased source distribution that work together. This method is reasonably automatic, is easy to use, and has been implemented in the Automated Variance reduction Generator (ADVANTG) package that works with MCNP5. ADVANTG reads an MCNP input file and a small amount of extra user information and then runs an adjoint deterministic calculation using Denovo. The importance map and biased source distribution derived from the CADIS method can then be incorporated back into the original MCNP input file to enhance the figure-of-merit (FOM) of the calculation. The FOM is a measure of the efficiency of the calculation using the amount of run time and corresponding level of statistical uncertainty in the detector result. ADVANTG-enhanced MCNP input files have been shown to increase the FOM of many types of problems, obtaining the same level of statistical uncertainty in a shorter time compared to standard MCNP. ADVANTG can also generate variance reduction parameters (importance map and biased source) using the Forward-Weighted CADIS (FW-CADIS) method for optimizing mesh tallies. The CADIS method creates variance reduction parameters that optimize a tally's total quantity (flux, dose rate, interaction rate, etc.) and will not generally increase performance for all parts of a segmented tally. To optimize a segmented tally, the FW-CADIS method uses two discrete ordinates calculations to make variance reduction parameters that help compute a segmented tally with uniform relative uncertainties in each bin. This report will demonstrate that using ADVANTG for neutron and photon radiation shielding problems will (1) preserve the standard MCNP results and (2) obtain those results either with less statistical uncertainty or in shorter times than the standard MCNP calculation. The four demonstration problems in this report are based on simple neutron or photon transmission measurements through different materials. All of the problems here used the CADIS method and still saw improvement across the flux tallies segmented by particle energy. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Analytical calculation for the solid angle subtended at an arbitrarily positioned point source by an ellipse - Paper 38

The geometrical solid angle can be used to calibrate radiation detectors or to determine the activity of radioactive sources. In the present work, we introduce a direct analytical method for calculating the solid angle subtended at an arbitrarily positioned point source by a closed contour (ellipse). The validity of the derived analytical expressions was successfully confirmed by the comparison with some published data (Numerical Method). Direct mathematical expressions to calculate the geometrical solid angle subtended by an elliptical disk detector with respect to arbitrarily positioned radiating point sources have been derived. The agreement between the calculated and the published solid angle values is excellent; the discrepancies were (0.0%). This means that the present approach is efficient and sufficiently powerful to evaluate the geometrical efficiency of the elliptical disk detectors. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

ITS version 6.4: The Integrated TIGER Series of Monte Carlo Electron/Photon Radiation Transport Codes - Paper 40

ITS (Integrated TIGER Series) is a suite of fully coupled electron/photon Monte Carlo radiation transport codes. The package contains programs to perform 1D, 2D and 3D simulations. The 3D geometry representations include the traditional combinatorial geometry (CG), facet-based models, CAD models for those users who have a license for the ACIS{sup R} CAD libraries, and hybrid models of any combination. There is a multigroup version which permits adjoint analysis. The availability of source code permits the more sophisticated user to tailor the code to specific applications and to extend the capabilities of the codes to more complex applications. ITS is presently available only through a U.S.-government-use license. It is available once again through the Radiation Safety Information Computational Center (RSICC). (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

MCNP6 Gets Correlated with CGM 3.4 - Paper 41

Version 3.4 of the Cascading Gamma-ray Multiplicity (CGM) code has been integrated into version 6 of the Monte Carlo radiation transport code MCNP. The current release is MCNP6 which is the merger of MCNPX 2.7.0 and MCNP5. MCNP6 is a general purpose Monte Carlo radiation transport code that can transport 34 different particles and heavy ions. CGM was originally integrated into MCNPX 2.7.0 as an undocumented feature, but was never released to the public. With the integration of CGM into MCNP6 the code now has the capability of producing correlated secondary particle/gamma emissions and should be available in future release of MCNP. Before the integration of CGM, MCNP only used libraries that contain the total multiplicity but not the multiplicity distribution or the correlations. Lacking this information requires the code to use integer sampling to determine the multiplicity. In the example of thermal neutron capture on Cl-35, presented in the results section, MCNP does integer sampling. This means MCNP would produce one gamma 17% of the time and two gammas 82% giving a mean multiplicity of 1.83. Using CGM, MCNP can now produce a spectrum of multiplicities. The use of CGM has several advantages over the use of ACE data libraries in MCNP6: 1) it has correlated gamma production, 2) it produces a distribution of gamma multiplicities per interaction, whereas ACE produces an average between two integer multiplicities, 3) it is a theoretical model that may predict experimentally unmeasured physical quantities that may not be in experimental based data libraries. CGM conserves energy and angular momentum internally to CGM; however, angular emission information is not currently sent back to MCNP6. Future work will include the integration of correlated neutrons from CGM. Also, the reaction type will be passed to CGM to set the spin and parity for a particular reaction when possible. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Study of {sup 31}P(n,α){sup 28}Al reaction using d(d,n){sup 3}He for the possible interference with {sup 27}Al(n,γ){sup 28}Al - Paper 44

At McMaster we use neutrons from the {sup 7}Li(p,n){sup 7}Be reaction to measure aluminum in human subjects via the {sup 27}Al(n,γ){sup 28}Al reaction. We use proton energies of between 1.9 MeV and 2.3 MeV, yielding maximum neutron energy of 0.575 MeV. In principle, {sup 28}Al can also be produced via the {sup 31}P(n,α){sup 28}Al reaction, which has a neutron energy threshold of 2.008 MeV. When aluminum is measured in bone, there can be 10{sup 5} times the mass of phosphorus present as there is aluminum. However, this potential interference cannot arise using the {sup 7}Li(p,n){sup 7}Be reaction in the proton energy range specified. Collaborators at Atomic Energy of Canada Limited (AECL), Chalk River, Purdue University in the USA and Shanxi Medical University in Taiyuan, China are also interested in being able to measure aluminum in bone in living human subjects. Both AECL and Purdue have acquired D-D sets (accelerators producing neutrons via the d(d,n){sup 3}He reaction). These operate at high current (∼mA) and relatively low accelerating voltage (150 kV), relying on quantum mechanical tunneling through the Coulomb barrier. These D-D sets produce neutrons of energy 2.565 MeV. This is above the threshold for the {sup 31}P(n,α){sup 28}Al reaction, but we have not been able to find any report in which this reaction has had a cross section measurably greater than zero for neutron energies of less than 3 MeV. So, it is an open question as to whether the potential interfering reaction with phosphorus is a concern when using neutrons from a D-D set to measure aluminum in bone. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose reduction techniques in a nuclear manufacturing facility - Paper 46

The Atomic Weapons Establishment plays a crucial role in the defence of the United Kingdom. AWE is the home of the UK's nuclear deterrent, where we build and maintain warheads for Trident, a submarine-launched ballistic missile. This talk will describe a number of dose reduction initiatives employed at the main plutonium manufacturing building which has seen a reduction in worker dose of around 60%. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose Reconstruction In The Former Village Of Metlino In The Contaminated Techa River Region, Southern Urals, Russia - Paper 51

This work reports on the reconstruction of radiation exposure at the former village of Metlino in Southern Urals, Russia within the SOLO project (Epidemiological Studies of Exposed Southern Urals Populations) funded by the European Union. Metlino is located 7 km from the Mayak Production Association (PA) at an area of the Techa river that was exposed to a considerable amount of radiation circa 60 years ago. Today the Mayak worker cohort (MWC), the extended Techa River cohort (ETRC), and the Techa River offspring cohort (TROC), are amongst the most important sources of late health effects associated with low-dose rate exposure to plutonium, strontium and external gamma radiation. (authors)

54 ENVIRONMENTAL SCIENCES↗

Determination of activation products and resulting decommissioning implications for the Varian TruBeam linear accelerator - Paper 52

Modern medical linear accelerators used for the treatment of cancers are capable of operating at electron energies as high as 20 MeV. Above electron energies of 6 MeV, a measurable dose rate is obtained at the isocenter after beam termination. This is attributed to the activation of linear accelerator components through photonuclear reactions and neutron capture. Photons are produced as Bremsstrahlung during the collision of high-energy electrons with a heavy metal target, typically comprised of copper or tungsten. When photons exceeding the nucleon binding energy interact with a nucleus, neutrons are ejected. In the process of neutron capture, neutrons produced through ({gamma}, n) reactions are absorbed by a nucleus and the excess energy is emitted as a photon. Over the lifetime of an accelerator many components, such as the target, flattening filter, collimators, jaws, and treatment couch, are activated through these interactions. Although dependent on operating conditions, linear accelerators have an expected lifetime of 7 to 10 years. In Canada, at the end of their service, accelerators are typically sold for scrap, returned to a remanufacturing enterprise, or if the machine is still operational it can be retasked for continued use. Since many of the accelerator components have been exposed to a neutron fluence and activated to various extents, the requirements of the Canadian Nuclear Substance and Radiation Device regulations apply prior to final removal from the hospital. For shipments to the USA, there are exemption regulations to be considered. NRC regulation 10CFR 30.71 Schedule B lists a number of common radionuclides and the specific exemption quantity. Below these levels, radioactive materials may be freely transported from Canada to the USA without prior licensing from the Canadian Nuclear Safety Commission (CNSC) or United States Nuclear Regulatory Commission (NRC). (authors)

43 PARTICLE ACCELERATORS↗

Radiation protection at the SwissFEL free electron laser facility: Beam stopping devices - Paper 53

The new large-scale facility SwissFEL (Swiss Free Electron Laser) is currently under construction at the Paul Scherrer Institute. The facility is situated underground in the ground floor of a two-floor building, partly integrated in a recreation area. This results into new challenges for radiation protection related tasks, in particular for the design of beam-stopping devices. The design of each beam-stopping device has to ensure that the dose rate during operation outside of the accelerator vault is in compliance with the legal limits defined by the Swiss radiation protection ordinance. In this work, the final design of the dumps is presented with the description of the underlying operational and legal constraints. Reuse of activated material as concrete, lead and steel is included in the main design criteria. As a result, four beam stopping devices consist for more than 90 % of material already available at PSI. In addition, routine operation and maintenance scenarios are discussed from a radiation protection point of view. (authors)

42 ENGINEERING↗

Characterization Techniques for LiInSe{sub 2} Semiconducting Neutron Detector - Paper 55

As the world supply of helium continues to dwindle, alternatives to neutron detection have been a key focus area of radiation detection research. Solid-state neutron detectors are one possible alternative to the {sup 3}He detectors currently used for neutron detection when large detector areas are not required. Although {sup 6}Li and {sup 10}B are both also commonly used for neutron detection, neither has as high of a thermal cross section as {sup 3}He. The thermal cross sections for {sup 6}Li, {sup 10}B, and {sup 3}He are, respectively, 940 barns, 3840 barns, and 5330 barns. Both boron and helium are used in a gaseous form for neutron detection; however, there is no suitable gaseous form of lithium for neutron detection. Lithium is instead utilized in solid or liquid compounds for neutron detection. In this context, one area of interest is in the development of ternary A{sup I}B{sup III}C{sup IV} semiconductors comprised of isotopically-enriched lithium. Single crystal samples are being prepared through collaboration with the Y12 National Security Complex. This research focuses on the characterization of {sup 6}LiInSe{sub 2} (LISe) crystals, as well as on the development of prototype systems to assess the viability of using LISe crystals as a thermal neutron detector. Data to be obtained will provide previously untested physical parameters to facilitate growth optimization. Eventually, the refined crystals will be developed into solid-state, position-sensitive pixel detectors used for neutron imaging, among a wide array of possible applications including nuclear forensics. For the most part, the research team has been focused on mastering the detector fabrication processes, response tests on the first two batches of crystal samples, and the design of the first iteration detection system (Fig. 2). Response tests using alphas and neutrons have shown sensitivity to both particles. The first iteration detection system developed utilizes a 3-stage filter ladder of resistors and capacitors, similar to an ORTEC 142PC Preamplifier. Ideally, this ladder will reduce the noise associated with the high voltage power supply. The preamplifier is AC coupled to improve its counting rate capability (saturation), and critical components are on insulated posts. The custom circuit is housed in an aluminum box, and initial testing of the circuit has shown expected results. Investigation into further noise reduction is underway and will be the focus of the presented results. Upon completion and successful testing of the final detection system design, further development in spatial resolution and gamma/neutron discrimination will continue. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digitalized two parametric system for gamma/neutron spectrometry - Paper 59

Many types of detectors like stilbene, NE-213 etc. in conjunction with photomultiplier loaded with low working resistance produce pulses of approximately 100 ns length and contain information about deposited particle in the trailing edge. Using fast analog to digital converters (ADC) and field-programmable gate array (FPGA) it is possible to create a spectrometric system working in mixed gamma and neutron fields which is not loaded dead time. The count rate of processed pulses can reach more than one million per second. Such a high count rate of processed pulses can be achieved due to the pulse processing is implemented in FPGA. The output of this pulse processing is amplitude which describes the energy of deposited particle and discrimination parameter whereby it is possible to discriminate photons and neutrons. To increase the dynamic range of energy of detectable particle the signal from photomultiplier is separated into two branches with different amplification. Each branch is digitalized by separate ADC. Components from which the system is composed are so light that the spectrometer can be easily transported. Its weight is less than 3 kilograms. Spectrometer was tested in the research reactor LR-0 in Rez near Prague (Czech Republic). The measured data was processed using deconvolution into a neutron flux density and compared with nowadays used analog spectrometer and simulation result. Measured neutron spectrum of Cf-252 is included. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aircrew, Cancer and Probability of Causation - Paper 60

Aircrew are radiation workers who normally are not provided with dosimetry. The Energy Employees Occupational Illness Compensation Policy Act (EEOICPA) established an important legal precedent that fundamentally changed employer liability for companies that expose workers to radiation. We have applied the method used by EEOICPA (Interactive Radio Epidemiological Program (IREP)) to cancers found in excess in published epidemiological studies of aircrew. Our results show that from 4 to 8 of the 12 cancers reported in the literature in typical aircrew may be compensable using EEOICPA methods. The other cancers may be compensable as well, given an unusual flight career with greater exposures than typical. Our research demonstrates there are cancers that have a 50% POC at annual exposures within the range of those asserted by the FAA for aircrew. The FAA currently estimates aircrew annual exposure as up to 6 mSv from GCR alone. While dosimetry is urgently needed for existing aircrew, historical dose reconstructions will be needed to address POC for aircrew diagnosed with a radiogenic cancer. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimization of the Shielding of a Canister Loading Machine with the deterministic Code Attila{sup R} - Paper 61

In general shielding components are designed with very conservative assumptions and boundary conditions to cover all possibly occurring situations. This often results in an overestimated shielding design in a lot of different fields of application; the shielding of components will be heavier and more expensive than needed. In most cases an initial shielding calculation in the design process shows an unbalanced shielding effect of the shielded radiation source. Sometimes the dose rate limits are slightly exceeded in several areas. From this arises a need for an optimization of the shielding structure. The goal is to decrease the radiation level in the accessible areas to keep the dose rate limits and to reduce the amount of the used shielding material if possible. Shielding material is moved from areas with higher shielding factors to which with lower ones. The optimization process is shown in an example of a loading machine for vitrified waste in canisters. The design review with an optimization of the shielding geometry was done with the deterministic code Attila{sup R} of the company Transpire, Inc. Attila{sup R} is a powerful tool to calculate and optimize the shielding effect of handling facilities for radioactive materials. It is easy to handle with its CAD integration module and an easy setup of the calculation cases. Areas with a low shielding effect which results in an exceeding of the dose rate limits can be found quickly with the illustration due to an Iso-Dose-Rate-Surface in the 3D Model. In these areas the shielding effect has to be improved. Otherwise there is material, which has no significant influence on the shielding effect and makes the handling facilities heavier and more expensive as needed. The optimization of the shielding design of the canister loading machine in the current case results in lower dose rates outside the facility to keep the dose rate limits. The demand of shielding material could be reduced and resulted in a cost reduction on the facility itself and furthermore in the caring facilities to transport this facility (cranes, etc.). (authors)

42 ENGINEERING↗

A Code of Radiation Damage by Gamma - Paper 62

In recent years, the study of radiation damage of materials has seen a thrust because of the expectation of the high rate of radiation damage in fusion reactors, accelerator driven sub critical systems and damage of a control system of space vehicles by the high energy neutrons and gamma showers. Embrittlement of reactor vessels, corrosion of steel and swelling of fuel rods are the well known empirical examples of severe radiation damage. It is also realized that damage by high energy gammas is in no way insignificant, and it is equivalent to the damage by the neutrons. Secondly, value addition of certain materials like enhancement of electrical resistance, mechanical strength, color enhancement of precious stones on irradiation by neutrons and gammas and polymerization in the presence of gamma radiation add to the necessity of a Monte Carlo (MC) code of radiation damage in a wide range of energy. The JAIPU code, for the study of radiation damage by neutrons up to 10 MeV energy, incorporates features like development of secondary atomic cascade and PKA energy corrected for the ionization lose and production of Frenkel pair. MC estimation of both the primary and secondary displacements has been compared with the Frenkel pairs calculated using the NRT model. In the present work, JAIPU code is extended for irradiation of materials by high energy gammas. Here cascade generated by the incident gamma produces electrons by way of photo-electric, Compton and pair production until it is absorbed. The recoiled Frenkel pairs produced in electron + atom collision have been considered for the purpose of atomic cascade. Standard cross section libraries for gamma and electron interaction are used while for atom + atom collision we have made use of the IOTA code. In addition, in the code, the lattice structure of the irradiated material is simulated to know the positions of the photon interactions with atoms and the energy of electron it adds an extra feature of the position and size of the voids and the clusters produced on irradiation. The code has the possibility of calculation of 'absorbed radiation dose' and 'KERMA' and the interatomic distances of the displaced atoms. It may be pointed out that the code uses only the MC simulation of the number of displacements unlike several other approaches where the NRT model with PKA energy is used for gross estimation of the number of the displaced atoms. Thus, the code keeps an account of the positions of displaced atoms for the in-depth modification of the irradiated material. 1 MeV gamma seems to damage Fe up to several millimeters of its depth and this is mostly by the recoiled Compton electrons than photo electrons. The code is in the developmental stage and it has the capability of applications in the developing field of Radiology besides the shielding and other studies of radiation damage. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗